}

Tender For Phase-2 Construction And Development Work Of Dev Van In Vineet Khand, Gomti Nagar Scheme.,1 Kids Play Equipments ( Ref. Senior Citizen Park) 2 Supplying And Fixing Of Standered Multi Seater See Saw Outdoor Playing Equipment Including Necessa, lucknow-Uttar Pradesh

Local Bodies has published Tender For Phase-2 Construction And Development Work Of Dev Van In Vineet Khand, Gomti Nagar Scheme.,1 Kids Play Equipments ( Ref. Senior Citizen Park) 2 Supplying And Fixing Of Standered Multi Seater See Saw Outdoor Playing Equipment Including Necessa. Submission Date for this Tender is 14-10-2024. Dustbin Tenders in lucknow Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

45531555
Tender For Phase-2 Construction And Development Work Of Dev Van In Vineet Khand, Gomti Nagar Scheme.,1 Kids Play Equipments ( Ref. Senior Citizen Park) 2 Supplying And Fixing Of Standered Multi Seater See Saw Outdoor Playing Equipment Including Necessa
Open Tender
Indian
Uttar Pradesh
Lucknow
14-10-2024

Tender Details

Tender for phase-2 construction and development work of Dev Van in Vineet Khand, Gomti Nagar Scheme.,1 KIDS PLAY EQUIPMENTS ( ref. senior citizen park) 2 Supplying and Fixing of Standered Multi seater See Saw outdoor playing equipment including necessaryfittings, T&P etc all complete in direction of engineer in charge.(Model No. FPSS12, Make Fun Play/ Kompain/ Arihant) PSR 3 Supplying and Fixing of Turbo Tower outdoor playing equipment including necessaryfittings, T&P etc all complete in direction of engineer in charge.(Model No.FPCL35 , Make Fun Play/ Kompain/ Arihant) PSR 4 Supplying and Fixing ofMonkey Climber outdoor playing equipment including necessaryfittings, T&P etc all complete in direction of engineer in charge.(Model No. FPCL43, Make Fun Play/ Kompain/ Arihant) PSR 5 Supplying and Fixing of Balancing Bridge outdoor playing equipment including necessaryfittings, T&P etc all complete in direction of engineer in charge. (Model No. FPTH41, Make Fun Play/ Kompain/ Arihant) PSR 6 Supplying and Fixing of Four Seater Merry Go Round outdoor playing equipmentincluding necessaryfittings, T&P etc all complete in direction of engineer in charge.(Model No.FPMR11, Make Fun Play/ Kompain/ Arihant) PSR 7 Supplying and Fixing of7 Ht. FRP Wave Slide outdoor playing equipment including necessaryfittings, T&P etc all complete in direction of engineer in charge.(Model No. FPSD51, Make Fun Play/ Kompain/ Arihant) PSR 8 Supplying and Fixing of Frog Bin - FRP outdoor playing equipmentincluding necessaryfittings, T&P etc all complete in direction of engineer in charge.(Model No.FPDB11, Make Fun Play/ Kompain/ Arihant) PSR 9 Supplying and Fixing of Imperial Bench 4 outdoor playing equipmentincluding necessaryfittings, T&P etc all complete in direction of engineer in charge.(Model No. FPGD11, Make Fun Play/ Kompain/ Arihant) PSR 10 HORTICULTURE 11 Supplying and stacking of well decayed cattle manure at site including royalty and carriage upto 5 k.m.lead complete (Cattle manure measured in stacks will reduced by 8% for Payment). DSR Horticulture 2020; 2.25 12 Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge DSR Horticulture 2020; 2.9 13 Spreading of sludge, dump manure and/or good earth in required thickness as per direction of officer-in-charge (cost of sludge, dump manure and/ or good earth to be paid separately). DSR Horticulture 2020; 2.8RA 14 Fine dressing of the ground DSR Horticulture 2020; 2.7, RA 15 Preparation of mounds of various size and shape by available excavated / supplied earth in layers not exceeding 20 cm in depth, breaking clods, watering of each layer, dressing etc., lead upto 50 meter and lift upto 1.5 m complete as per direction of Officer-in-charge. DSR Horticulture 2020; 2.25 16 Plantation Work 17 Plantation of Trees, Shrubs, and Hedge at site i/c watering and removal of unserveiceable material’s as per direction of officer in charge (excluding cast of plant & water) DSR Horticulture 2020; 2.57 RA 18 Hedge Plant /Ground cover 2.57.3 19 Grass Cover 20 Providing & laying Selection no. 1 doob grass turf with earth 50mm to60mm thickness of existing ground prepared with proper level and rammingwith required tools wooden and than rolling the surface with light rollermake the surface smoothen and light watering the same maintenance for30 days or more till the grass establish properly,as per direction of officer in charge DSR Horticulture 2020; 2.34 21 EDGE SHRUBS AROUND STRUCTURES AND PATHWAYS 22 Providing and stacking of Iresine herbstii, of height 20-30 cm. full of branches well developedin 15 cm size of Earthen Pot / Plastic Pot & as per direction of the officer-in-charge. DSR Horticulture 2020;10255 23 Bush Rose in different colour 2 to 3 healthy branch 30 cm and above ht. well developed with8 or more flowers / flower buds in 20 cm Earthen pot / Plastic pot as per direction of theofficer-in-charge. DSR Horticulture 2020;4.90 24 Providing and stacking of Chandni dwarf of height 15-20 cm., well branched in earthen potsof size 20 cm as per direction of the officer-in-charge. s per direction of the officer-in-char DSR Horticulture 2020;8.14 25 Providing and stacking of Clerodendrum inerme having ht. 25 cm to 30 cm multi branched in15 cm size of Earthen Pot / Plastic Pot & as per direction of the officer-in-charge. DSR Horticulture 2020; 6.7 26 Providing and Displaying Bougainvillea named variety, Sobhra, Thima, Marrypalmar, Cherry Blossom etc. well developed with fresh & healthy bushy infull bloom 75 to 90 cm ht. in 40 cm Cement Pot as per direction of theofficer-in-charge. DSR Horticulture 2020; 5.12 27 FLOWER GARDEN 28 AlyssumDSR Horticulture 2020; 10.1.1 29 Brachycome 10.1.4 30 Daisy hybrid 10.1.15 31 Dahlia double 10.1.14 32 Salvia Hybrid different colour 10.1.29 33 Gomphrena 10.2.5 34 Kochia 10.2.6 35 Portulaca hybrid 10.2.7 36 Vinca Hybrid 10.2.9 37 Zinnia hybrid 10.2.10 38 CIVIL WORK 39 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soil DSR 2023, 2.6 40 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. DSR 2.25 41 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mmnominal size) (PWD SOR 2021/SI-4.1.8) 42 Centering and shuttering including strutting, propping etc. and removal of form for :Foundations, footings, bases of columns, etc for mass concrete DSR 5.9.1 (UP SOR 8.20) 43 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) 6.4.2 44 12 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand) 13.4.1 45 Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) 13.46.1 46 Making bajri path including preparation of subgrade, supplying and laying brick aggregate of 50 mm nominal size 7.5 cm deep with blinding material consisting of 12 mm moorum and 12 mm red bajri consolidated with road roller. PWD SOR 2021/ 16.10 47 Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but Excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/recoverable separately).All Work Above Plinth Level DSR 5.33A 48 Reinforcement for RCC work including straightening, cutting, bending, placing in position complete. -Thermo-Mechanically Treated bars.PSR 49 Providing and fixing M.S. angle 50x50x5 mm to act as nosing with lugs of M.S. flat 10x5 mm, 10 cm long, forked at end 60cm apart (minimum three lugs to be provided), including necessary welding and applying a priming coat of approved primer on exposed surface etc. complete DSR 11.35 50 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. DSR 10.2 51 Providing wood work in frames of / Railing / false ceiling, partitionsetc. sawn and fixed in position with necessary stainless steel screws etc. Sal woodDSR 9.3.1 52 French spirit polishing :Two or more coats on new works including a coat of wood fillerDSR 13.68.1 53 Painting or Vanishing on iron works in small areas or new wood work with One coat of ready mixed priming paint & Two coats of approved superior ready mixed paint of clear syuthetic varnish including supply of all materials, labour and T & P etc. required for proper completion of work. Paint to be used should confirm to the I.S.I. No. 103 1950. DSR 13.67.1 54 Boaring/ drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS : 2800 part I, including collecting sample from different starta, preparing and submitting equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer In charge, up to 150 meter depth below ground level. 300 mm diaAll type of soil (DAR 23.2.1.1 based)Sanction Rate SOR 2020-21 55 Supply, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well casing (CM) pipe of required dia conforming to IS: 12818 including required hire and labour charges, fittings & accessories etc. all complete for all depths as per direction of Engineer in charge. 200 mm nominal size diaDAR No. 23.3.3 Sanction Rate 56 Supply, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818 including required hire and labour charges, fittings & accessories etc. all complete for all depths as per direction of Engineer in charge. 200 mm nominal size diaDAR No. 23.10.3 Sanction Rate 57 Supplying, filling, spreading & levelling gravels of size range 5 mm to 10 mm in the recharge pit, over the existing layer of boulders, in required thickness for all leads & lifts all complete as per direction of Engineer in charge. DAR 23.6 58 brick ballast 40 mm class 150PWD SOR 59 brick ballast 40 mm class 150 PWD SOR 60 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. (DSR 13.80) 61 Providing and laying 75 mm thick compacted bed of dry brick aggregate of 40 mm thick nominal size including spreading, well ramming, consolidating and grouting with jamuna sand, including finishing smooth etc. complete as per direction of Engineer-in-charge. PWD 16.64 62 Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.40 mm thick with 20 mm nominal size stone aggregate, PWD 11.3.1 63 Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.Size of Tile 600 x 1200 mmPWD 11.41A.1.3 64 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete.11.46.2 65 Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying:(a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm.(b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm.(c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/ sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around.(d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately.For the purpose of measurement the entire treated surface will be measured.PWD 22.6 66 SEATING 67 Providing & fixing sand stone Single piece ornamental bench of approved design pattern (1200x450x450MM) and specifications including, all materials, labour and T & Petc. required for proper completion of work as directed by engineer - in -charge PSR ( AYAPPA PHASE 1) 68 DUSTBINS 69 Providing & fixing of Dustbin made in mild steel frame with painting & polish and frame wooden member fixed in m.s. frame including painting polishing as per drawing & design all complete in direction of engineer in charge.PSR REF. from Khargapur 70 EXTERNAL LIGHTING AND ELECTRICAL 71 Supply and fixing of 3500mm decorative ribbed steel poles are made out of mild steel galvanized rebbed extrusion profile having bottom section dia125mm and upper section dia 81mm with cast iron embellishment e8 & with having for twin nos bracket. The pole have a service window at bottom section wih heavy duty four way connector and a mcb. Mild steal base plate with four nos. mounting holes is fixed and welded with bottom section . pole is primer coated and polyurethene painted . Ref. Rates Globe Park and Begum Hazrat Mahal Dev. 72 Supply and fixing of 534 mm long aluminium dia cast body post top is mounted at the top with polycarbonate diffuser and fitted with 40w led disc bis registered make philips , bajaj, twinkle, lustore or equivalent repuateted make Ref. Rates Globe Park and Begum Hazrat Mahal Dev. 73 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required sor 2018 E &M708 74 Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.DSR5.7(E&M) 2014 75 Supplying and laying 25 mm X 3 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)PWD 711 E-M 2018 SCHEUDLE 76 Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge ,complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.PWD 501,E-M 2018 SCHEUDLE 77 6.00 Sqmm 4 Core (g) 78 25.00 Sqmm 3.5 Core (J) 79 70.00 Sqmm 3.5 Core (M) 80 Supply and fixing following capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 series with contactors, HRC fuses, isolating switch metering instrument & instrument box with CTs etc. in case of TPN, complete in all respect.40 A TPN PWD 807 f 81 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mmnominal size) (PWD SOR 2021/SI-4.1.8) 82 Centering and shuttering including strutting, propping etc. and removal of form work for : Retaining walls, return walls, walls (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc. .(PWD SOR 2021/SI-4.3.2) 83 PAINTING 84 Painting of graphics on the wall till 2 - 2.5 meter s in height in specific designs and colors as guided by engineer in charge PSR 85 SPEAKER SYSTEM ( REF. FROM BEGUM HAZRAT MAHAL) 86 Supplyinstallationtesting andcommisioning of weatherised Two-Way 5.25 inch (135mm) Coaxial Speaker with Components:• 5¼” highly weather-resistant driver• ¾” soft-dome highly weather-resistant tweeter and can handle 80WPinkNoise PowerHandling(160Wprogram)indirect8Ώ setting, plus built-in 30W 70V/100V multi-tap transformer, should have Fully isolated center chamber for wiring protection, Frequency Response (-10 dB): 55 Hz - 18 kHz; (±3 dB): 65Hz - 16 kHz;PowerRating1:160WcontinuousProgram(2hrs),80W (320W peak), Continuous Pink Noise (2 hrs), 45 W (180W peak) Continuous Pink Noise (100hrs), Maximum Input Voltage: 23.3 V,Sensitivity2:86dB,1W@1m(ave.80Hz-16kHz),Nominal Coverage Angle: 360° horizontal, 160° vertical (primary listening 10°to 50°upfromground),Directivity Index(DI):3.4dB, Maximum SPL 3: 105 dB @ 1m, Low Frequency Driver: 135 mm (5.25in)diameterLFdriver,Kapton™former,35.5mm(1.4in) voice coil, polypropylene cone and polyurethane surround, High Frequency:19mm(0.75in)diameterHFdriverPolyetherimide (PEI) dome. Complete in all respects and as directed by engineer in charge. (JBL/Bose/TW Audio/L Aucostic) complete in all respect as directed by Engineer-in-charge.. MR 87 Supply, installation, testing and commissioning ofAmplifiers for Main Speakers with Four-channel 2400 WattNetwork amplifier withDSPwithClassD/TDtechnology,PowerHandling:4× 2400W @ 4/8 Ohms, 4 × 950 W @ 16 ohms Max power per channel in case of bridge mode / Power managmenet should be 4200watts @ 4 ohms and 4800 watts @ 8ohms,InputSignaltoNoiseRatio >108dB,LoadImpedance Stereo/Dual Mode 2Ω - 16Ω; 70Vrms and 100Vrms 96KHz SampleRate; DSPFeatures:classic/linear-phase/FIRspeaker processing platform with four throughputs; DSP Features: Group control with Raised Cosine MESA EQ asymmetric filters Peak and RMS limiters, Support Multiple make Speaker presets Comprehensiveclockingmanagementsystemwithlowlatency samplerateconversion;ProtectionFeatures:VeryHigh Frequency Protection ,DirectCurrentProtection ,Short Circuit Protection,Temperatureprotectionetc,Eightdual-redundant Dante network audio inputs, 4 Analog Inputs, Control port Certifictaion:CE,ETL(ANSI/UL,CSA),BIS.(Crown/Bose/TW Audio/L Aucostic) complete in all respect as directed by Engineer-in-charge.. MR 88 Supplying,installationTestingandCommissioningof2Cx4sq mmCopperSpeakerCableinPVCConduitofspecifiedmake, complete with all accessories etc complete as as per the attached approved make list and with proper connections etccomplete in all respect as directed by Engineer-in-charge.. 89 Supplying,installationTestingandCommissioningof2x2.5sq mmCopperSpeakerCableinPVCConduitofspecifiedmake, complete as per the attached approved make list and with proper connections etccomplete in all respect as directed by Engineer-in-charge.. MR 90 Supply,Installation,testingandcommissioningofSpeakercagemade of SS Jali for theft protection. complete in all respect as directed by Engineer-in-charge.. MR 91 Supply, Installation,testingand commissioningofPoE Ethernet Controllerwith minimum8programmablebuttonandVolume Control,dual-gang US Decoraor dual-gang EU formfactor, push/rotary encoder, encoder ring, with sleep functionality, supportminimum2LCDscreenhaving64x128pixelsscreen resolution, Configured within Audio Architect via drag-and-drop, powerconsumption300mAmaxat48VDCwithVW-1Rated. (JBL/Bose/TW Audio/L Aucostic) complete in all respect as directed by Engineer-in-charge.. MR 92 SURVILLANCE SYSTEM 93 PLINTH AREA RATES CPWD 2023, Supply installation , testing and commissioning of IP based CCTV system for building security comprising of PTZ/FIXED CAMERA, CABLING , RECORDING , DISPLAY SYSTEM HARDWARE SOFTWARE SUPPORT,FOR EXTERNAL SURVILLANCE 6.10.2 , For two entrances only 94 INTERNAL ELECTRICAL WORKS 95 GATE 96 WIRINGPOINTS 97 Wiring point for light with 1.0 sq.mm FR P.V.C. insulated multistrandsingle core Copper Conductor cable in heavy gauge rigid steel conduit pipepartly concealedin wall&partlylaidin slab along with the reinforcement before concreting complete with 14 S.W.Gcopper earth continuity wire&piano typeswitchetc. complete in all respects. (AS PER UPPWD -2018) 138 B 98 Same as in item no. 1 but for fan. and light duty exhaust fan (AS PER UPPWD -2018) 140 B 99 Same as in item no. 1butfor 5ampplug point with piano type switch & socket etc. (AS PER UPPWD -2018) 141 B 100 Add for light / fan points with modular type switches in place of piano type switches (AS PER UPPWD -2018) 187 A 101 Add for plug point with modular switch & socket in place of piano type switch & socket. (AS PER UPPWD -2018) 187 C 102 Supply & fixing of power plugwith20amp 250 volts flush type modular switchand 5 pin 20 amp 250 volts flush type universal modular socket on concealed MS box including supply of all material, labour T&P etc. required for proper completion of work (AS PER UPPWD -2018) 139 A 103 MAINS & SUBMAINS 104 Supply & wiringofsubmainwithFR P.V.C. insulated1100 volts grade singlecorecopper conductorcable in heavygaugerigid steel coduit partly concealedinwall and partly laid inslab alongwith the reinforcement before concreting complete withone no. 14 SWGcopperearth continuity wire complete in all respects. 105 2 x 4 sq. mm.In 20 mm dia conduit. (AS PER UPPWD -2018) 221 B 106 2 x 10 sq. mm.In 25 mm dia conduit. (AS PER UPPWD -2018) 223 B 107 DISTRIBUTIONBOARDS&CIRCUITBREAKERS 108 S/F of surface / flush mounting SPN Distribution board (Legrand Lexic) without MCB complete in all respects as directed at site by Engineer-in-charge. 109 12 WAYS CAT-B (AS PER UPPWD -2018) 1025A 110 Supply & fixingof 6/10/16/20/25/32 amp. SP MCB (10 KA) (Legrand Lexic) (AS PER UPPWD -2018) 1002 111 S/F of 40 Amp DP MCB (10 KA)(Legrand Lexic) (AS PER UPPWD -2018) 1010 112 S/F of sheet steelenclosure for DP / TP / FP MCB with neutral link and earth terminal. CAT-B (AS PER UPPWD -2018) 1033 113 EARTHING 114 Supply&burryingof 600mm x 600mm x 6.0mm G.I. plate, vertically for earthing with its top at least 3 m below ground level complete 20mm dia. G.I.pipe and funnelforwatering and one earthing lead ofno. 8SWGG.I. wirein 15 mm dia. GI pipe uptoswitch board (from apron to switch boardthecost of GI pipe & GI wire willbeextra)300mm square C.I. box with hinged cover,masonary housing alternate layer of charcoal/coke and salt atleast 150mm thick alround etc. as per the direction of engineer in-charge complete in all respect .(AS PER UPPWD -2018) 703 115 Supplying & Laying of one number 8 SWG G. I. wirein 15 mm. dia. G. I.pipefor earthing, laidin groundor inwall duly concealedincludingthecostofcement, sand, labour, T&Pandothermaterial required for proper completion ofthework as directed at site. (AS PER UPPWD -2018) 721 116 CABLES 117 Supply andlayingofISI marked aluminiumconductor PVC / XLPE insulated armoured,served,sheathed cable 1100volts gradeat 750mmbelow ground level overacushion of 75 mm thick sand around & protected with brick onsides & top on surfacethecablerunshallbe fixed on M.S. clamps etc. of suitablesize completeinallrespect. The armouring of the cable shall be properlyconnectedwith the earth conductor by clamps etc. 10 sqmm 2core (AS PER UPPWD -2018) 501 118 Supplyfixing of plam orpintypecopper tin plated cable socket (lug) tothecable leads, insulating with tapeand making connections etc. complete in all respects as per direction of Engineer-in-charge. 10 sq.mm.(AS PER UPPWD -2018) 504 119 Supply andfixing brass nickle plated compression glandsfor PVC insulated armoured,served,sheathed cable including rubber ring etc.completeinallrespect. The armouring of the cable shall be properlyconnectedwith the earth conductor. 10 sqmm 2core (AS PER UPPWD -2018) 503 120 Erection and testing of exhaust fan on the existing hole with suitable size of rag bolts nuts and washers etc complete in all respects.(AS PER UPPWD -2018) 1120 121 Supply and fixing of 16 gauge MS drum duly painted including making hole in the wall for exhaust fan and finishing properly complete in all respect. (AS PER UPPWD -2018) 1122 122 Supply & fixing of recess/surface/ pendent mounting round10 to 15 watt LED Down lighter having powder coated die cast aluminium housing with heat silk, diffuser/ reflector and driver set complete in all respect.(AS PER UPPWD -2018) 1402 123 Supply & fixing ofLED tube light with batten suitable for upto 1x22 watt LED tube light fittings including tube on surface complete in all respect Cat- AAA (AS PER UPPWD -2018) 1413 124 Supply & fixing of recess/ surface mounting round 24 watt to 32 watt LED down lighter having powder coated die cast alumnium housing with extended heat sink, diffuser / Reflector and driver set completed in all respect. (AS PER UPPWD -2018) 1404 125 Supply ofAC230/250 volts, 50 HZ fresh airfansincluding providingnuts, bolts, mounting frame and other accessories etc.complete(Make : Bajaj / Usha / newtek / Havells) 300 mm sweep (M.R.) 126 Supply of AC230/250 volts, 50 HZ exhaust fansincluding providingnuts, bolts, mounting frame and other accessories etc.complete(Make : Bajaj / Crompton / Havells) 300 mm sweep 900 rpm 127 LIBRARY AND SHOP 128 WIRINGPOINTS 129 Wiring point for light with 1.0 sq.mm FR P.V.C. insulated multistrandsingle core Copper Conductor cable in heavy gauge rigid steel conduit pipepartly concealedin wall&partlylaidin slab along with the reinforcement before concreting complete with 14 S.W.Gcopper earth continuity wire&piano typeswitchetc. complete in all respects. (AS PER UPPWD -2018) 138 B 130 Same as in item no. 1 but for fan. and light duty exhaust fan(AS PER UPPWD -2018) 140 B 131 Same as in item no. 1butfor 5ampplug point with piano type switch & socket etc. (AS PER UPPWD -2018) 141 B 132 Add for light / fan points with modular type switches in place of piano type switches (AS PER UPPWD -2018) 187 A 133 Add for plug point with modular switch & socket in place of piano type switch & socket (AS PER UPPWD -2018) 187 C 134 Supply & fixing of power plugwith20amp 250 volts flush type modular switchand 5 pin 20 amp 250 volts flush type universal modular socket on concealed MS box including supply of all material, labour T&P etc. required for proper completion of work (AS PER UPPWD -2018) 139 A 135 MAINS & SUBMAINS 136 Supply & wiringofsubmainwithFR P.V.C. insulated1100 volts grade singlecorecopper conductorcable in heavygaugerigid steel coduit partly concealedinwall and partly laid inslab alongwith the reinforcement before concreting complete withone no. 14 SWGcopperearth continuity wire complete in all respects. 137 2 x 4 sq. mm.In 20 mm dia conduit. (AS PER UPPWD -2018) 221B 138 2 x 10 sq. mm.In 25 mm dia conduit. (AS PER UPPWD -2018) 223B 139 DISTRIBUTIONBOARDS&CIRCUITBREAKERS 140 S/F of surface / flush mounting SPN Distribution board (Legrand Lexic) without MCB complete in all respects as directed at site by Engineer-in-charge. 141 12 WAYS CAT-B (AS PER UPPWD -2018) 1025 A 142 Supply & fixingof 6/10/16/20/25/32 amp. SP MCB (10 KA) (Legrand Lexic) (AS PER UPPWD -2018) 1002 143 S/F of 40 Amp DP MCB (10 KA)(Legrand Lexic) (AS PER UPPWD -2018) 1010 144 S/F of sheet steelenclosure for DP / TP / FP MCB with neutral link and earth terminal. CAT-B(AS PER UPPWD -2018) 1033 145 EARTHING 146 Supply&burryingof 600mm x 600mm x 6.0mm G.I. plate, vertically for earthing with its top at least 3 m below ground level complete 20mm dia. G.I.pipe and funnelforwatering and one earthing lead ofno. 8SWGG.I. wirein 15 mm dia. GI pipe uptoswitch board (from apron to switch boardthecost of GI pipe & GI wire willbeextra)300mm square C.I. box with hinged cover,masonary housing alternate layer of charcoal/coke and salt atleast 150mm thick alround etc. as per the direction of engineer in-charge complete in all respect .(AS PER UPPWD -2018) 703 147 Supplying & Laying of one number 8 SWG G. I. wirein 15 mm. dia. G. I.pipefor earthing, laidin groundor inwall duly concealedincludingthecostofcement, sand, labour, T&Pandothermaterial required for proper completion ofthework as directed at site. (AS PER UPPWD -2018) 721 148 CABLES 149 Supply andlayingofISI marked aluminiumconductor PVC / XLPE insulated armoured,served,sheathed cable 1100volts gradeat 750mmbelow ground level overacushion of 75 mm thick sand around & protected with brick onsides & top on surfacethecablerunshallbe fixed on M.S. clamps etc. of suitablesize completeinallrespect. The armouring of the cable shall be properlyconnectedwith the earth conductor by clamps etc. 10 sqmm 2core (AS PER UPPWD -2018) 501 150 Supplyfixing of plam orpintypecopper tin plated cable socket (lug) tothecable leads, insulating with tapeand making connections etc. complete in all respects as per direction of Engineer-in-charge. 10 sq.mm. (AS PER UPPWD -2018) 504 151 Supply andfixing brass nickle plated compression glandsfor PVC insulated armoured,served,sheathed cable including rubber ring etc.completeinallrespect. The armouring of the cable shall be properlyconnectedwith the earth conductor. 10 sqmm 2core (AS PER UPPWD -2018) 503 152 Erection and testing of exhaust fan on the existing hole with suitable size of rag bolts nuts and washers etc complete in all respects. (AS PER UPPWD -2018) 1120 153 Supply and fixing of 16 gauge MS drum duly painted including making hole in the wall for exhaust fan and finishing properly complete in all respect. (AS PER UPPWD -2018) 1122 154 Supply & fixing of recess/surface/ pendent mounting round10 to 15 watt LED Down lighter having powder coated die cast aluminium housing with heat silk, diffuser/ reflector and driver set complete in all respect. (AS PER UPPWD -2018) 1402 155 Supply & fixing ofLED tube light with batten suitable for upto 1x22 watt LED tube light fittings including tube on surface complete in all respect Cat- AAA (AS PER UPPWD -2018) 1413 156 Supply & fixing of recess/ surface mounting round 24 watt to 32 watt LED down lighter having powder coated die cast alumnium housing with extended heat sink, diffuser / Reflector and driver set completed in all respect. (AS PER UPPWD -2018) 1404 157 Supply ofAC230/250 volts, 50 HZ fresh airfansincluding providingnuts, bolts, mounting frame and other accessories etc.complete(Make : Bajaj / Usha / newtek / Havells) 300 mm sweep M.R. 158 Supply of AC230/250 volts, 50 HZ exhaust fansincluding providingnuts, bolts, mounting frame and other accessories etc.complete(Make : Bajaj / Crompton / Havells) 300 mm sweep 900 rpm M.R. 159 HALL (ELECTRICALINSTALLATIONS) 160 WIRINGPOINTS 161 Wiring point for light with 1.0 sq.mm FR P.V.C. insulated multistrandsingle core Copper Conductor cable in heavy gauge rigid steel conduit pipepartly concealedin wall&partlylaidin slab along with the reinforcement before concreting complete with 14 S.W.Gcopper earth continuity wire&piano typeswitchetc. complete in all respects. (AS PER UPPWD -2018) 138 B 162 Same as in item no. 1 but for fan. and light duty exhaust fan(AS PER UPPWD -2018) 140 B 163 Same as in item no. 1butfor 5ampplug point with piano type switch & socket etc. (AS PER UPPWD -2018) 141 B 164 Add for light / fan points with modular type switches in place of piano type switches (AS PER UPPWD -2018) 187A 165 Add for plug point with modular switch & socket in place of piano type switch & socket (AS PER UPPWD -2018) 187 C 166 Supply & fixing of power plugwith20amp 250 volts flush type modular switchand 5 pin 20 amp 250 volts flush type universal modular socket on concealed MS box including supply of all material, labour T&P etc. required for proper completion of work (AS PER UPPWD -2018) 139 A 167 MAINS & SUBMAINS 168 Supply & wiringofsubmainwithFR P.V.C. insulated1100 volts grade singlecorecopper conductorcable in heavygaugerigid steel coduit partly concealedinwall and partly laid inslab alongwith the reinforcement before concreting complete withone no. 14 SWGcopperearth continuity wire complete in all respects. 169 2 x 4 sq. mm.In 20 mm dia conduit. (AS PER UPPWD -2018) 221 B 170 2 x 10 sq. mm.In 25 mm dia conduit. (AS PER UPPWD -2018)223 B 171 DISTRIBUTIONBOARDS&CIRCUITBREAKERS 172 S/F of surface / flush mounting SPN Distribution board (Legrand Lexic) without MCB complete in all respects as directed at site by Engineer-in-charge. 173 12 WAYS CAT-B (AS PER UPPWD -2018)1025 A 174 Supply & fixingof 6/10/16/20/25/32 amp. SP MCB (10 KA) (Legrand Lexic) (AS PER UPPWD -2018)1002 175 S/F of 40 Amp DP MCB (10 KA)(Legrand Lexic) (AS PER UPPWD -2018)1010 176 S/F of sheet steelenclosure for DP / TP / FP MCB with neutral link and earth terminal. CAT-B (AS PER UPPWD -2018)1033 177 EARTHING 178 Supply&burryingof 600mm x 600mm x 6.0mm G.I. plate, vertically for earthing with its top at least 3 m below ground level complete 20mm dia. G.I.pipe and funnelforwatering and one earthing lead ofno. 8SWGG.I. wirein 15 mm dia. GI pipe uptoswitch board (from apron to switch boardthecost of GI pipe & GI wire willbeextra)300mm square C.I. box with hinged cover,masonary housing alternate layer of charcoal/coke and salt atleast 150mm thick alround etc. as per the direction of engineer in-charge complete in all respect . (AS PER UPPWD -2018)703 179 Supplying & Laying of one number 8 SWG G. I. wirein 15 mm. dia. G. I.pipefor earthing, laidin groundor inwall duly concealedincludingthecostofcement, sand, labour, T&Pandothermaterial required for proper completion ofthework as directed at site.(AS PER UPPWD -2018)721 180 CABLES 181 Supply andlayingofISI marked aluminiumconductor PVC / XLPE insulated armoured,served,sheathed cable 1100volts gradeat 750mmbelow ground level overacushion of 75 mm thick sand around & protected with brick onsides & top on surfacethecablerunshallbe fixed on M.S. clamps etc. of suitablesize completeinallrespect. The armouring of the cable shall be properlyconnectedwith the earth conductor by clamps etc. 182 10 sqmm 2core (AS PER UPPWD -2018)501 183 Supplyfixing of plam orpintypecopper tin plated cable socket (lug) tothecable leads, insulating with tapeand making connections etc. complete in all respects as per direction of Engineer-in-charge. 184 10 sq.mm. (AS PER UPPWD -2018)504 185 Supply andfixing brass nickle plated compression glandsfor PVC insulated armoured,served,sheathed cable including rubber ring etc.completeinallrespect. The armouring of the cable shall be properlyconnectedwith the earth conductor. 186 10 sqmm 2core (AS PER UPPWD -2018)503 187 Erection and testing of exhaust fan on the existing hole with suitable size of rag bolts nuts and washers etc complete in all respects. (AS PER UPPWD -2018)1120 188 Supply and fixing of 16 gauge MS drum duly painted including making hole in the wall for exhaust fan and finishing properly complete in all respect. (AS PER UPPWD -2018)1122 189 Supply & fixing ofLED tube light with batten suitable for upto 1x22 watt LED tube light fittings including tube on surface complete in all respect Cat- AAA (AS PER UPPWD -2018)1413 190 Supply & fixing of recess/ surface mounting round 24 watt to 32 watt LED down lighter having powder coated die cast alumnium housing with extended heat sink, diffuser / Reflector and driver set completed in all respect. (AS PER UPPWD -2018) 1404 191 Supply ofAC230/250 volts, 50 HZ fresh airfansincluding providingnuts, bolts, mounting frame and other accessories etc.complete(Make : Bajaj / Usha / newtek / Havells) 300 mm sweep M.R. 192 Supply of AC230/250 volts, 50 HZ exhaust fansincluding providingnuts, bolts, mounting frame and other accessories etc.complete (Make : Bajaj / Crompton / Havells) 300 mm sweep 900 rpm M.R. 193 LIBRARY AND SHOP (ELECTRICALINSTALLATIONS) 194 WIRINGPOINTS 195 Wiring point for light with 1.0 sq.mm FR P.V.C. insulated multistrandsingle core Copper Conductor cable in heavy gauge rigid steel conduit pipepartly concealedin wall&partlylaidin slab along with the reinforcement before concreting complete with 14 S.W.Gcopper earth continuity wire&piano typeswitchetc. complete in all respects. (AS PER UPPWD -2018) 138 B 196 Same as in item no. 1 but for fan. and light duty exhaust fan(AS PER UPPWD -2018) 140 B 197 Same as in item no. 1butfor 5ampplug point with piano type switch & socket etc. (AS PER UPPWD -2018) 141 B 198 Add for light / fan points with modular type switches in place of piano type switches(AS PER UPPWD -2018) 187 A 199 Add for plug point with modular switch & socket in place of piano type switch & socket (AS PER UPPWD -2018) 187 C 200 Supply & fixing of power plugwith20amp 250 volts flush type modular switchand 5 pin 20 amp 250 volts flush type universal modular socket on concealed MS box including supply of all material, labour T&P etc. required for proper completion of work (AS PER UPPWD -2018) 139 A 201 MAINS & SUBMAINS 202 Supply & wiringofsubmainwithFR P.V.C. insulated1100 volts grade singlecorecopper conductorcable in heavygaugerigid steel coduit partly concealedinwall and partly laid inslab alongwith the reinforcement before concreting complete withone no. 14 SWGcopperearth continuity wire complete in all respects. 203 2 x 4 sq. mm.In 20 mm dia conduit.(AS PER UPPWD -2018) 221 B 204 2 x 10 sq. mm.In 25 mm dia conduit. (AS PER UPPWD -2018) 223 B 205 DISTRIBUTIONBOARDS&CIRCUITBREAKERS 206 S/F of surface / flush mounting SPN Distribution board (Legrand Lexic) without MCB complete in all respects as directed at site by Engineer-in-charge. 207 12 WAYS CAT-B (AS PER UPPWD -2018) 1025 A 208 Supply & fixingof 6/10/16/20/25/32 amp. SP MCB (10 KA) (Legrand Lexic) (AS PER UPPWD -2018) 1002 209 S/F of 40 Amp DP MCB (10 KA)(Legrand Lexic) (AS PER UPPWD -2018) 1010 210 S/F of sheet steelenclosure for DP / TP / FP MCB with neutral link and earth terminal. CAT-B (AS PER UPPWD -2018) 1033 211 EARTHING 212 Supply&burryingof 600mm x 600mm x 6.0mm G.I. plate, vertically for earthing with its top at least 3 m below ground level complete 20mm dia. G.I.pipe and funnelforwatering and one earthing lead ofno. 8SWGG.I. wirein 15 mm dia. GI pipe uptoswitch board (from apron to switch boardthecost of GI pipe & GI wire willbeextra)300mm square C.I. box with hinged cover,masonary housing alternate layer of charcoal/coke and salt atleast 150mm thick alround etc. as per the direction of engineer in-charge complete in all respect .(AS PER UPPWD -2018) 703 213 Supplying & Laying of one number 8 SWG G. I. wirein 15 mm. dia. G. I.pipefor earthing, laidin groundor inwall duly concealedincludingthecostofcement, sand, labour, T&Pandothermaterial required for proper completion ofthework as directed at site. (AS PER UPPWD -2018) 721 214 CABLES 215 Supply andlayingofISI marked aluminiumconductor PVC / XLPE insulated armoured,served,sheathed cable 1100volts gradeat 750mmbelow ground level overacushion of 75 mm thick sand around & protected with brick onsides & top on surfacethecablerunshallbe fixed on M.S. clamps etc. of suitablesize completeinallrespect. The armouring of the cable shall be properlyconnectedwith the earth conductor by clamps etc.10 sqmm 2core 501 216 Supplyfixing of plam orpintypecopper tin plated cable socket (lug) tothecable leads, insulating with tapeand making connections etc. complete in all respects as per direction of Engineer-in-charge. 10 sq.mm. (AS PER UPPWD -2018) 504 217 Supply andfixing brass nickle plated compression glandsfor PVC insulated armoured,served,sheathed cable including rubber ring etc.completeinallrespect. The armouring of the cable shall be properlyconnectedwith the earth conductor. 10 sqmm 2core (AS PER UPPWD -2018)503 218 Erection and testing of exhaust fan on the existing hole with suitable size of rag bolts nuts and washers etc complete in all respects. (AS PER UPPWD -2018) 1120 219 Supply and fixing of 16 gauge MS drum duly painted including making hole in the wall for exhaust fan and finishing properly complete in all respect. (AS PER UPPWD -2018) 1122 220 Supply & fixing of recess/surface/ pendent mounting round10 to 15 watt LED Down lighter having powder coated die cast aluminium housing with heat silk, diffuser/ reflector and driver set complete in all respect. (AS PER UPPWD -2018)1402 221 Supply & fixing ofLED tube light with batten suitable for upto 1x22 watt LED tube light fittings including tube on surface complete in all respect Cat- AAA (AS PER UPPWD -2018) 1413 222 Supply & fixing of recess/ surface mounting round 24 watt to 32 watt LED down lighter having powder coated die cast alumnium housing with extended heat sink, diffuser / Reflector and driver set completed in all respect. (AS PER UPPWD -2018) 1404 223 Supply ofAC230/250 volts, 50 HZ fresh airfansincluding providingnuts, bolts, mounting frame and other accessories etc.complete(Make : Bajaj / Usha / newtek / Havells) 300 mm sweep M.R. 224 Supply of AC230/250 volts, 50 HZ exhaust fansincluding providingnuts, bolts, mounting frame and other accessories etc.complete (Make : Bajaj / Crompton / Havells) 300 mm sweep 900 rpm 225 GUARD ROOM (ELECTRICALINSTALLATIONS) 226 WIRINGPOINTS 227 Wiring point for light with 1.0 sq.mm FR P.V.C. insulated multistrandsingle core Copper Conductor cable in heavy gauge rigid steel conduit pipepartly concealedin wall&partlylaidin slab along with the reinforcement before concreting complete with 14 S.W.Gcopper earth continuity wire&piano typeswitchetc. complete in all respects. (AS PER UPPWD -2018) 138 B 228 Same as in item no. 1 but for fan. and light duty exhaust fan(AS PER UPPWD -2018) 140 B 229 Same as in item no. 1butfor 5ampplug point with piano type switch & socket etc. (AS PER UPPWD -2018) 141 B 230 Add for light / fan points with modular type switches in place of piano type switches(AS PER UPPWD -2018) 187 A 231 Add for plug point with modular switch & socket in place of piano type switch & socket (AS PER UPPWD -2018) 187 C 232 Supply & fixing of power plugwith20amp 250 volts flush type modular switchand 5 pin 20 amp 250 volts flush type universal modular socket on concealed MS box including supply of all material, labour T&P etc. required for proper completion of work (AS PER UPPWD -2018) 139 A 233 MAINS & SUBMAINS 234 Supply & wiringofsubmainwithFR P.V.C. insulated1100 volts grade singlecorecopper conductorcable in heavygaugerigid steel coduit partly concealedinwall and partly laid inslab alongwith the reinforcement before concreting complete withone no. 14 SWGcopperearth continuity wire complete in all respects. 235 2 x 4 sq. mm.In 20 mm dia conduit.(AS PER UPPWD -2018) 221 B 236 2 x 10 sq. mm.In 25 mm dia conduit. (AS PER UPPWD -2018) 223 B 237 DISTRIBUTIONBOARDS&CIRCUITBREAKERS 238 S/F of surface / flush mounting SPN Distribution board (Legrand Lexic) without MCB complete in all respects as directed at site by Engineer-in-charge. 239 12 WAYS CAT-B (AS PER UPPWD -2018) 1025 A 240 Supply & fixingof 6/10/16/20/25/32 amp. SP MCB (10 KA) (Legrand Lexic) (AS PER UPPWD -2018) 1002 241 S/F of 40 Amp DP MCB (10 KA)(Legrand Lexic) (AS PER UPPWD -2018) 1010 242 S/F of sheet steelenclosure for DP / TP / FP MCB with neutral link and earth terminal. CAT-B (AS PER UPPWD -2018) 1033 243 EARTHING 244 Supply&burryingof 600mm x 600mm x 6.0mm G.I. plate, vertically for earthing with its top at least 3 m below ground level complete 20mm dia. G.I.pipe and funnelforwatering and one earthing lead ofno. 8SWGG.I. wirein 15 mm dia. GI pipe uptoswitch board (from apron to switch boardthecost of GI pipe & GI wire willbeextra)300mm square C.I. box with hinged cover,masonary housing alternate layer of charcoal/coke and salt atleast 150mm thick alround etc. as per the direction of engineer in-charge complete in all respect .(AS PER UPPWD -2018) 703 245 Supplying & Laying of one number 8 SWG G. I. wirein 15 mm. dia. G. I.pipefor earthing, laidin groundor inwall duly concealedincludingthecostofcement, sand, labour, T&Pandothermaterial required for proper completion ofthework as directed at site. (AS PER UPPWD -2018) 721 246 CABLES 247 Supply andlayingofISI marked aluminiumconductor PVC / XLPE insulated armoured,served,sheathed cable 1100volts gradeat 750mmbelow ground level overacushion of 75 mm thick sand around & protected with brick onsides & top on surfacethecablerunshallbe fixed on M.S. clamps etc. of suitablesize completeinallrespect. The armouring of the cable shall be properlyconnectedwith the earth conductor by clamps etc.10 sqmm 2core 501 248 Supplyfixing of plam orpintypecopper tin plated cable socket (lug) tothecable leads, insulating with tapeand making connections etc. complete in all respects as per direction of Engineer-in-charge. 10 sq.mm. (AS PER UPPWD -2018) 504 249 Supply andfixing brass nickle plated compression glandsfor PVC insulated armoured,served,sheathed cable including rubber ring etc.completeinallrespect. The armouring of the cable shall be properlyconnectedwith the earth conductor. 10 sqmm 2core (AS PER UPPWD -2018)503 250 Erection and testing of exhaust fan on the existing hole with suitable size of rag bolts nuts and washers etc complete in all respects. (AS PER UPPWD -2018) 1120 251 Supply and fixing of 16 gauge MS drum duly painted including making hole in the wall for exhaust fan and finishing properly complete in all respect. (AS PER UPPWD -2018) 1122 252 Supply & fixing of recess/surface/ pendent mounting round10 to 15 watt LED Down lighter having powder coated die cast aluminium housing with heat silk, diffuser/ reflector and driver set complete in all respect. (AS PER UPPWD -2018)1402 253 Supply & fixing ofLED tube light with batten suitable for upto 1x22 watt LED tube light fittings including tube on surface complete in all respect Cat- AAA (AS PER UPPWD -2018) 1413 254 Supply & fixing of recess/ surface mounting round 24 watt to 32 watt LED down lighter having powder coated die cast alumnium housing with extended heat sink, diffuser / Reflector and driver set completed in all respect. (AS PER UPPWD -2018) 1404 255 Supply ofAC230/250 volts, 50 HZ fresh airfansincluding providingnuts, bolts, mounting frame and other accessories etc.complete(Make : Bajaj / Usha / newtek / Havells) 300 mm sweep M.R. 256 Supply of AC230/250 volts, 50 HZ exhaust fansincluding providingnuts, bolts, mounting frame and other accessories etc.complete (Make : Bajaj / Crompton / Havells) 300 mm sweep 900 rpm 257 LIBRARY (PLUMBING WORKS ) 258 Providing, fixing, jointing and testing in position of ISI marked UV stabilized UPVC pipesfor soil, waste, and vent, Type-B as per IS : 13592 suitable for rubber ring joints, including all neccessary specials and fittings (confirming to IS:14735) i.e. bends, tees, junctions (with or without doors),reducers, WC connectors, couplers, expansion joints / bellows, cowels, clamps, rubber rings, clean outs etc. fixing at wall/ ceiling/ floor level supported by clamp & hangers etc. in concealed / inside duct / under floor & basement ceiling / external work etc. including chase cutting as required, excavation and back filling in all kind of soils, suspended from floor under false ceiling or embedding the pipes laid under floors / building in 75 mm. alround 1:2:4 cement concrete (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including cost of shuttering for proper completion of the work, breaking and making good the walls and floors etc. after pipes have been duly laid and tested. The rubber ring shall confirm to IS:5382. (Make : Supreme / Finolex / Prince) 259 110 mm dia (Wall Thickness - 3.2 to 3.8 mm) 260 75 mm dia (Wall Thickness - 3.2 to 3.8 mm) 261 Providing, fixing, jointing and testing in position ISI marked (IS:4985) UPVC pipes of min 6 Kg/ Sqcm rating with fitting for waste pipe from fixtures to floor trap including reduces, enlarger, socket, couplers, bends, tees etc including fixing at wall/ ceiling level supported by clamp & hangers etc. cutting holes in wall/ floors/ slabs and making good the same with cement concrete 1:2:4 complete as required. (Make : Supreme / Finolex / Prince) 50 mm dia. 262 Providing & fixing UPVC Floor trap of self cleansing designwith CP Jalicomplete in all respects. (Make : Supreme / Finolex / Prince) P-Trap type Floor Trap 110 x 75 mm 263 Extra for providing & fixing 125 mm dia C.P. grating in place of C.I. grating over floor traps.M.R. 264 Providing & fixing 50 mm. dia. G.I elbow (drain point) in the toilet floor including50 mm dia. C.P. waste jali complete as required. M.R. 265 HALL PLUMBING WORKS 266 Providing, fixing, jointing and testing in position of ISI marked UV stabilized UPVC pipesfor soil, waste, and vent, Type-B as per IS : 13592 suitable for rubber ring joints, including all neccessary specials and fittings (confirming to IS:14735) i.e. bends, tees, junctions (with or without doors),reducers, WC connectors, couplers, expansion joints / bellows, cowels, clamps, rubber rings, clean outs etc. fixing at wall/ ceiling/ floor level supported by clamp & hangers etc. in concealed / inside duct / under floor & basement ceiling / external work etc. including chase cutting as required, excavation and back filling in all kind of soils, suspended from floor under false ceiling or embedding the pipes laid under floors / building in 75 mm. alround 1:2:4 cement concrete (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including cost of shuttering for proper completion of the work, breaking and making good the walls and floors etc. after pipes have been duly laid and tested. The rubber ring shall confirm to IS:5382. (Make : Supreme / Finolex / Prince) 267 110 mm dia (Wall Thickness - 3.2 to 3.8 mm) 268 75 mm dia (Wall Thickness - 3.2 to 3.8 mm) 269 Providing, fixing, jointing and testing in position ISI marked (IS:4985) UPVC pipes of min 6 Kg/ Sqcm rating with fitting for waste pipe from fixtures to floor trap including reduces, enlarger, socket, couplers, bends, tees etc including fixing at wall/ ceiling level supported by clamp & hangers etc. cutting holes in wall/ floors/ slabs and making good the same with cement concrete 1:2:4 complete as required. (Make : Supreme / Finolex / Prince) 50 mm dia. 270 Providing & fixing UPVC Floor trap of self cleansing designwith CP Jalicomplete in all respects. (Make : Supreme / Finolex / Prince) P-Trap type Floor Trap 110 x 75 mm 271 Extra for providing & fixing 125 mm dia C.P. grating in place of C.I. grating over floor traps. 272 Providing & fixing 50 mm. dia. G.I elbow (drain point) in the toilet floor including50 mm dia. C.P. waste jali complete as required. 273 KITCHENPLUMBING WORKS 274 ACCESSORIES 275 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : PWD 19.7 (DAR17.10) 276 Providing and fixing the taps attached to the shower divertor and the the sink M.R. 277 Providing and fixing the shower heads M.R. 278 Providing and fixing the shower divertersM.R. 279 Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete. 32 mm dia (for wash basin) PWD 17.28.1.1 280 WATER SUPPLY PIPES AND FITTINGS 281 Providing, fixing chlorinated polyvinyl Chloride (CPVC) pipes, havingthermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipes with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in charge. 282 Internal work exposed on wall 283 40mm nominal outer dia pipes. (PWD 18.75) 284 50mm nominal outer dia pipes PWD 18.9.6 285 Providing, fixing chlorinated polyvinyl Chloride (CPVC) pipes, havingthermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipes with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in charge. 286 Concealed work including cutting chase and making good the wall etc. 287 15mm nominal outer dia pipes PWD 18.8.1 288 20mm nominal outer dia pipes PWD 18.8.2 289 25mm nominal outer dia pipes PWD 18.8.3 290 32mm nominal outer dia pipes PWD 18.84 291 Providing & fixing gun metal gate valve with C.I. wheel of approvedquality (screwed end) 292 40 mm nominal bore PWD 18.17.3 293 50 mm nominal bore PWD 18.17.4 294 Providing&fixing15 mm nominal bore45 cm long unplasticised PVC connection pipewith brass unions.DSR 18.21.2.1 295 Providing & fixing 15 mm nominal bore CP brass bib cockof approved quality conformingtoIS 8931. PWD18.49.1 296 Providing and fixing 15 mm nominal bore C.P brass long nose bib cock of approved qualityconforming to IS standardsandweighing notlessthan 810 gms. PWD 18.50.1 297 Providing & fixing 15 mm nominal bore C.P. brassstop cock (concealed)of standard designandof approvedmakeconforming to IS : 8931.PWD 18.52.1 298 Providing & fixing 15 mm nominal bore C.P brass angle valve for basin mixer and geyser points of approved quality conformingto IS8931. PWD 18.53.1 299 Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever requiredRange of four urinal basins with 10 litre white P.V.C. automatic flushing cistern PWD 17.4.4 300 Constructing brick masonry chamber 300 x 300x500mm, insidewithF.P.S. brick work in cement mortar 1: 4 (1 cement : 4 coarse sand) for StopCock, withC. I. surface box 100 x 100 x 75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4mix (1cement : 2 coarse sand:4 grade stone aggregate 20mm nominal size); necessary excavation, foundationconcrete 1:5:10 (1 cement :5 fine sand: 10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar1 : 3 (1 cement : 3 coarse sand )12mmthick finished with a floatingcoatof neat cementcomplete as per standard designDSR 18.32.1 301 Providing and fixing square mouthS. W. Gully trapgrade `A complete with C.I. gratingbrickmasonry chamber with F.P.S bricks and water tight CI cover with frame of 300 x 300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design 150 x 100 mm. size P type PWD 19.4.2.1 &19.4.2 302 Providing and fixing PTMT Bottle Trap for Wash basin and sink. Bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms DSR 17.70.1 303 Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms. DSR 17.72 304 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. PWD 18.48 305 SUPPLYOFSANITARY FIXTURES, ACCESSORIESANDBATHROOMFITTINGS 306 Providing & fixing of white vitreous china urinal partition for half stall urinals. (Jaquar or equivalent) M.R. 307 Providing, fixing, jointing and testing in position of ISI marked UV stabilized UPVC pipesfor soil, waste, and vent, Type-B as per IS : 13592 suitable for rubber ring joints, including all neccessary specials and fittings (confirming to IS:14735) i.e. bends, tees, junctions (with or without doors),reducers, WC connectors, couplers, expansion joints / bellows, cowels, clamps, rubber rings, clean outs etc. fixing at wall/ ceiling/ floor level supported by clamp & hangers etc. in concealed / inside duct / under floor & basement ceiling / external work etc. including chase cutting as required, excavation and back filling in all kind of soils, suspended from floor under false ceiling or embedding the pipes laid under floors / building in 75 mm. alround 1:2:4 cement concrete (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including cost of shuttering for proper completion of the work, breaking and making good the walls and floors etc. after pipes have been duly laid and tested. The rubber ring shall confirm to IS:5382. (Make : Supreme / Finolex / Prince) 308 110 mm dia (Wall Thickness - 3.2 to 3.8 mm) 309 75 mm dia (Wall Thickness - 3.2 to 3.8 mm) 310 Providing, fixing, jointing and testing in position ISI marked (IS:4985) UPVC pipes of min 6 Kg/ Sqcm rating with fitting for waste pipe from fixtures to floor trap including reduces, enlarger, socket, couplers, bends, tees etc including fixing at wall/ ceiling level supported by clamp & hangers etc. cutting holes in wall/ floors/ slabs and making good the same with cement concrete 1:2:4 complete as required. (Make : Supreme / Finolex / Prince) 311 50 mm dia. 312 Providing & fixing UPVC Floor trap of self cleansing designwith CP Jalicomplete in all respects. (Make : Supreme / Finolex / Prince) 313 P-Trap type Floor Trap 110 x 75 mm 314 Extra for providing & fixing 125 mm dia C.P. grating in place of C.I. grating over floor traps. 315 Providing & fixing 50 mm. dia. G.I elbow (drain point) in the toilet floor including50 mm dia. C.P. waste jali complete as required. 316 GUARD ROOM AND TOILET BLOCK PLUMBING WORKS 317 ACCESSORIES 318 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : PWD 19.7 (DAR17.10) 319 Providing and fixing the taps attached to the shower divertor and the the sink 320 Providing and fixing the shower heads 321 Providing and fixing the shower diverters 322 Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete. 323 32 mm dia (for wash basin) PWD 17.28.1.1 324 WATER SUPPLY PIPES AND FITTINGS 325 Providing, fixing chlorinated polyvinyl Chloride (CPVC) pipes, havingthermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipes with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in charge. 326 Internal work exposed on wall 327 40mm nominal outer dia pipes 18.7.5 328 50mm nominal outer dia pipes 18.9.6 329 Providing, fixing chlorinated polyvinyl Chloride (CPVC) pipes, havingthermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipes with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in charge. 330 Concealed work including cutting chase and making good the wall etc. 331 15mm nominal outer dia pipes 18.8.1 332 20mm nominal outer dia pipes 18.8.2 333 25mm nominal outer dia pipes18.8.3 334 32mm nominal outer dia pipes 18.8.4 335 Providing & fixing gun metal gate valve with C.I. wheel of approvedquality (screwed end) 336 40 mm nominal bore 18.17.3 337 50 mm nominal bore 18.17.4 338 Providing&fixing15 mm nominal bore45 cm long unplasticised PVC connection pipewith brass unions. 18.21.2.1 339 Providing & fixing 15 mm nominal bore CP brass bib cockof approved quality conformingtoIS 8931. 18.49.1 340 Providing and fixing 15 mm nominal bore C.P brass long nose bib cock of approved qualityconforming to IS standardsandweighing notlessthan 810 gms.18.50.1 341 Providing & fixing 15 mm nominal bore C.P. brassstop cock (concealed)of standard designandof approvedmakeconforming to IS : 8931. 18.52.1 342 Providing & fixing 15 mm nominal bore C.P brass angle valve for basin mixer and geyser points of approved quality conformingto IS8931.18.53.1 343 Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever requiredRange of four urinal basins with 10 litre white P.V.C. automatic flushing cistern 17.4.4 344 Constructing brick masonry chamber 300 x 300x500mm, insidewithF.P.S. brick work in cement mortar 1: 4 (1 cement : 4 coarse sand) for StopCock, withC. I. surface box 100 x 100 x 75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4mix (1cement : 2 coarse sand:4 grade stone aggregate 20mm nominal size); necessary excavation, foundationconcrete 1:5:10 (1 cement :5 fine sand: 10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar1 : 3 (1 cement : 3 coarse sand )12mmthick finished with a floatingcoatof neat cementcomplete as per standard design 18.32.1 345 Providing and fixing square mouthS. W. Gully trapgrade `A complete with C.I. gratingbrickmasonry chamber with F.P.S bricks and water tight CI cover with frame of 300 x 300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design 150 x 100 mm. size P type PWD 19.4.2.1 &19.4.2 346 Providing and fixing PTMT Bottle Trap for Wash basin and sink. Bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms DSR 17.70.1 347 Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms. DSR 17.72 348 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. PWD 18.48 349 SUPPLYOFSANITARY FIXTURES, ACCESSORIESANDBATHROOMFITTINGS 350 Providing & fixing of white vitreous china urinal partition for half stall urinals. (Jaquar or equivalent) 351 Providing, fixing, jointing and testing in position of ISI marked UV stabilized UPVC pipesfor soil, waste, and vent, Type-B as per IS : 13592 suitable for rubber ring joints, including all neccessary specials and fittings (confirming to IS:14735) i.e. bends, tees, junctions (with or without doors),reducers, WC connectors, couplers, expansion joints / bellows, cowels, clamps, rubber rings, clean outs etc. fixing at wall/ ceiling/ floor level supported by clamp & hangers etc. in concealed / inside duct / under floor & basement ceiling / external work etc. including chase cutting as required, excavation and back filling in all kind of soils, suspended from floor under false ceiling or embedding the pipes laid under floors / building in 75 mm. alround 1:2:4 cement concrete (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including cost of shuttering for proper completion of the work, breaking and making good the walls and floors etc. after pipes have been duly laid and tested. The rubber ring shall confirm to IS:5382. (Make : Supreme / Finolex / Prince) 352 110 mm dia (Wall Thickness - 3.2 to 3.8 mm) 353 75 mm dia (Wall Thickness - 3.2 to 3.8 mm) 354 Providing, fixing, jointing and testing in position ISI marked (IS:4985) UPVC pipes of min 6 Kg/ Sqcm rating with fitting for waste pipe from fixtures to floor trap including reduces, enlarger, socket, couplers, bends, tees etc including fixing at wall/ ceiling level supported by clamp & hangers etc. cutting holes in wall/ floors/ slabs and making good the same with cement concrete 1:2:4 complete as required. (Make : Supreme / Finolex / Prince) 50 mm dia. 355 Providing & fixing UPVC Floor trap of self cleansing designwith CP Jalicomplete in all respects. (Make : Supreme / Finolex / Prince) P-Trap type Floor Trap 110 x 75 mm 356 Extra for providing & fixing 125 mm dia C.P. grating in place of C.I. grating over floor traps. 357 Providing & fixing 50 mm. dia. G.I elbow (drain point) in the toilet floor including50 mm dia. C.P. waste jali complete as required.

Key Value

Document Fees
INR 4366 /-
EMD
INR 310400.0 /-
Tender Value
INR 1.55 Crore /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail