}

Tender For Nawabganj Nagar Palika Parishad Construction Repairing Of Over Head Tank Pump House Boundarywall Staff Quarter Gate Site Development. Laying Jointing Of Rising Main Distribution System. Construction Of Newrebore Tube Wells Including Plc Scada A, nawabganj-Uttar Pradesh

Uttar Pradesh Jal Nigam has published Tender For Nawabganj Nagar Palika Parishad Construction Repairing Of Over Head Tank Pump House Boundarywall Staff Quarter Gate Site Development. Laying Jointing Of Rising Main Distribution System. Construction Of Newrebore Tube Wells Including Plc Scada A. Submission Date for this Tender is 29-10-2024. Tube Well Tenders in nawabganj Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

45525667
Corrigendum : Tender For Nawabganj Nagar Palika Parishad Construction Repairing Of Over Head Tank Pump House Boundarywall Staff Quarter Gate Site Development. Laying Jointing Of Rising Main Distribution System. Construction Of Newrebore Tube Wells Including Plc Scada A
Open Tender
Indian
Uttar Pradesh
Nawabganj
29-10-2024

Tender Details

tender for Nawabganj Nagar Palika Parishad Construction Repairing Of Over Head Tank Pump House Boundarywall Staff Quarter Gate Site Development. Laying Jointing Of Rising Main Distribution System. Construction Of Newrebore Tube Wells Including Plc Scada Automation Of Nawabganj NPP Water Supply Reorgnization and House Connection Scheme Sl. No. Item Description 1 Provide all materials, labour, T&P etc. complete and constructed pump house of size (3.0X3.60) cum chlorinating room of size (1.80X2.60) and By Pass Chamber as per departmental type design and drawing. 2 Repairing & painting of existing pump house of cum chlorinating room of sizeincluding supply of all labour, material, T&P etc complete as per direction of Engineer In Charge 3 Rising Main for Zone 1 to 14 4 Supply of following sizes of D.I pipesclass K-7/9 withalljointingmaterials including supply of all type of specials asperIS- 8329/2000 or its latest amendments including F.O.R. destination and all taxes and insurance etc. complete 5 200 mm dia DI.K-9 6 150 mm dia DI.K-9 7 Supply of following sizes of D.I double flangedsluicevalveasperI.S:14846:2000 working pressure 10 Kg/cm2 F.O.R. destination and all taxes and insurance. 8 200 mm 9 150 mm 10 Carting of following sizes D.I.D/F Sluice valve and specials from departmental store to site of work and lowering theminto the trenches, fixing in position and jointing them with pipelines and testing etc. complete (including supply of jointing materials) 11 200 mm 12 150 mm 13 Excavationfor pipe line trenches in ordinary soil(loam,clayorsand)includingliftupto 1.5m and refilling, watering, ramming of excavated earth into trenches anddisposal of surplus earth up to 50m from the center of thefoundation trenches. 14 Carting of following sizes D.I. pipes class K- 7/9 and specials to the site of work lowering them in to trench and laying true to alignment includingtestingofpipelinebutexcluding cost of trenching and cutting of pipes etc. formaking of length but including making joints. 15 200 mm dia DI.K-9 16 150 mm dia DI.K-9 17 Dismantling of following type road and stackingofusefulmaterial andtemporary reinstatementofroadwitholdmaterialsetc.complete. 18 Bituminous Road 19 Reinstatement of following type road and stackingofusefulmaterial andtemporary reinstatementofroadwitholdmaterialsetc.complete. 20 Bituminous Road Bituminous Road on PWD stretch as per PWD specification.1.granular sub-base With material conforming to Grade-I (size range 75 mm to 0.075 mm ) having CBR Value-25 125 mm layer thickness.2.granular sub-base With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBR Value-25 125 mm layer thickness.3. Providing, laying, Spreading & Compacting graded stone aggregateto wet mix macadam. (150 mm thickness)4. Providing & applying PrimeCoat with medium bitumen VG 10 on prepared surfacespreading primer at the rate of 0.75 Kg./Sqm.5.P/L of 50mm thick DBM with 100-120 TPH batch type HMP Producing and Avg. Output of 75 TPH using crushed aggt. Of specified grading premixed with bituminous binder VG 30 @ 3.5 %5.P/L of 40mm thick BC with 100-120 TPH batch type HMP Producing and Avg. Output of 75 TPH using crushed aggt. Of specified grading premixed with bituminous binder VG 30 @ 5.5 %6.Providing and laying seal coat over prepared surface of road with bitumen heated in bitumen boiler fitted with the spray set spraying using 98 kg of bitumen of grade VG - 10 and blinding surface with 0.90 cum of stone aggregate of 6.7 mm size7. Providing all necessary barricating and road painting work. 21 Supply of all material labour, T&P etc. Required and construct of Sluice Valve Chamber Masonry Type as per type design. 22 Thrust Block 23 R.C.C. with cement, coarse sand & 20 mm gauge stone ballast in proportion of 1:1.5:3 in thrust blocks of pipe line excluding supply of reinforcement & its bending but including its fixing & binding the same with 0.50 mm thick binding wire in position & necessary centering & shuttering including curing and supply of all materials, labour, T & P etc. required for proper completion of the work. 24 Mild steel or iron work in R.C.C. wrought to required shape as necessary including bending for proper completion of the work including supply of steel & wastage etc. 25 R.C.C. OHT 26 RENOVATION OF EXISTING OVER HEAD TANKS WHICH INCLUDES FOLLOWING ITEMS:Providing and erection of scaffolding and shuttering material like challi, gurra, nail, bans, ballia, patra etc. required for complete of work on all surgace area of OHT from top dome to G.L. so as to give strong and safe plateform to workers to work on all part of OHT for repair and strengthning as per direction of engineer in charge. Surface Preparation- The surface of structure to be treated for strengthning shall be reoughened properly either by raking joints or by haching the cement concrete surface with a specially made haching tool or otherwise alternatively to /make the surface rough and dust free byproviding spatter key or wire brush.Injection grouting in vertical surface/wall placing and fixing nozzle by drilling machine in tank wall having minimum dia of nozzle 15mm and provide on a regular interval not exceeding 1m including construction joints. Injection of pidicrete AM (Ploymer based on shrinkage high strength grout) admisxed with cement through nozle under pressure by sump @ 250gms per bag of cement sealing the nozzle after frounting with Ploymer product mixed with cement, making tank body in working and seapage free condition.Changeofsteelladderinsidethetank,repairof MH cover of top dome, change of mosqeuto jali with new one complete. Supply and fixing of 20mm dia G.I.Pipe railing in stair case and balcony. (Taking only 25% new and 75% old materials) Laying and fixing of 3mm thick MS wire mesh on roof of slab for nominal reinforcement including cost of all labour, materials, T&P etc required for completion of work25 mm thick 1:2:4 plain cement concrete flooring in apron with cement coarse sand and 20mm gauge stone ballast, laid in panels Finished with 3mm floating coat of neat cement of cement including 75mm thick base concrete of 1:4:8 including supply of all material. PaintingofoutersurfaceofOHTwithwheather proof paint (like apex etc.) as per direction of engineer in-charge. Painting of iron work with 1 coat primer & 2 coats of approved emultion paint as per direction of engineer incharge. 27 Zone-1, 1600 kL Capacity 16 M Staging 28 Zone-2, 1900 kL Capacity 18 M Staging 29 Zone-3, 1600 kL Capacity 18 M Staging 30 Zone-4, 1900 kL Capacity 18 M Staging 31 Zone-7, 1200 kL Capacity 16 M Staging 32 Zone-9, 600 kL Capacity 18 M Staging 33 Zone-12, 600 kL Capacity 16 M Staging 34 Construction of New OHT 35 Supply of all materials labour T&P etc. complete and construction of R.C.C. (M30 Grade)Over Head Tank of following capacity and staging above ground level with all work complete, including cost of soil testing. All the components of OHT will be casted in M30 concrete & specially in M-30 construction of water bearing structure with cement, coarse sand and approved stone grit as per I.S. 11682, I.S.3370 part (I) & (II) and I.S.456.Minimum depth of foundation below original ground level will be 2.5M. Seismic effects and wind load should be taken into consideration as I.S. 1893 for earthquake resistance and as per I.S. 875 part-III for wind load on structure (this area is in seismic Zone IV and high damage risk zone for wind).The cost of OHT should be quoted assuming the bearing capacity of soil as 8 M.T.per sqm. including 1 M wide RCC staircase from ground level to balcony. M.S. ladder made of 50x50x6 mm angle section and 20mm plain M.S. bars (specification of M.S. should be as per IS 800-2007) with hand rails of 20mm medium class G.I. pipes on both sides in three rows from balcony to top dome resting on an RCC platform (75cmx75cm and 10cm thick) projecting from top ring beam and one aluminum ladder inside the tank body (from manhole in top dome to bottom as per design and specification approved by Engineer in charge. 1 m wide R.C.C. M25 balcony around the tank at the junction point of vertical wall and conical wall. Proper railing of 20mm dia medium class G.I. pipe (in 3 rows) on both sides of stair case, around the balcony, at each landing and from landing with top ring beam upto manhole on the top dome and at the periphery of top dome. The G.I. Pipes will be supported on M.S. posts made of or RCC post, spaced at intervals not more than 1.5m.Proper ventilator at top dome in circular shape of 1.2 m dia. along with an R.C.C. cover of minimum 1.50m dia and with mosquito net of standard quality along with expanded metaled jali between top dome and RCC cover. Water level indicator fabricated with good quality minimum 45mm x 45mm x 6mm M.S. angle with indicator board scale made 50x50x6mm M.S. angle section, of 3mm thick M.S. plate should have a clear width of minimum 25cm painted with good paint with brass wire rope, pulley, copper ball float, pointer etc. Lightening conductor should be as per I.S.S.2309 or its latest amendments of latest electricity rules. C.I. manhole cover of min 60x60cm size with locking arrangement, Supply, fixing & jointing of C.I.D./F Pipes (for inlet, outlet, washout and overflow pipes) and specials, duck foot bend and fixing of the sluice valve at outlet and wash put pipe with all specials; construction of sluice valve chamber, floor and apron with semi circular drain around the apron with 25mm PCC 1:2:4 over 75 mm PCC 1:4:8, Apex painting on outer surface of OHT, painting on MS ladder, railing, vertical pipe etc. as per approved make; excavation in all type of soil and all other works required for proper and complete construction 36 Zone-5, 1800 kL Capacity 22 M Staging 37 Zone-6, 1800 kL Capacity 18 M Staging 38 Zone-8, 1200 kL Capacity 18 M Staging 39 Zone-10, 2200 kL Capacity 22 M Staging 40 Zone-11, 1900 kL Capacity 20 M Staging 41 Zone-13, 600 kL Capacity 22 M Staging 42 Zone-14, 600 kL Capacity 22 M Staging 43 Construction of CWR 44 Zone-1, 400 kL Capacity 45 Zone-2, 500 kL Capacity 46 Zone-3, 400 kL Capacity 47 Zone-4, 500 kL Capacity 48 Zone-7, 300 kL Capacity 49 Zone-8, 600 kL Capacity 50 Zone-10, 600 kL Capacity 51 Distribution System Zone 1 to 14 52 Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m 53 Supply of following sizes and type of pipes with all jointing materials such as socket, rubber gasket as per IS IS-4984-2016 and IS 8329/2000 or their latest amendment including F.O.R destination and all taxes and insurance etc. with loading, Unloading and stacking all complete 54 HDPE Pipe (Grade PE-100) PN-6 55 90mm diaO.D. 56 110mm dia O.D. 57 140 mm dia O.D. 58 160 mm dia O.D. 59 10 % for Electrofusion Specials of Item Sr 54 to 59 60 DI Pipe K-7 61 200mm dia 62 250mm dia 63 300mm dia 64 350mm dia 65 400mm dia 66 450mm dia 67 500mm dia 68 10 % for DI Specials of Item Sr 60 to 68 69 Carting, laying and jointing by Electrofusion Method of the following sizes ofpipe intothetrenchesincludingcostofall jointingmaterial,labour,T&Pandtestingetc, complete. The rate includes all material, labour and T&P for electrofusion jointing (Excluding Cost of Electrofusion Specials ) of HDPE pipe. 70 HDPE Pipe (Grade PE-100) PN-6 71 90mm diaO.D. 72 110mm dia O.D. 73 140 mm dia O.D. 74 160 mm dia O.D. 75 DI Pipe K-7 76 200mm dia 77 250mm dia 78 300mm dia 79 350mm dia 80 400mm dia 81 450mm dia 82 500mm dia 83 Supply of following types of fitting including rail wayfreight,cartageuptostore, all taxesand insurance.D.I.D/FSluiceValve/ScourValveas per IS 14846:2000 suitable for working pressure10 kg/cm2. 84 D.I.D/F Sluice Valve 85 80mm dia 86 100mm dia 87 125mm dia 88 150mm dia 89 200mm dia 90 250mm dia 91 300mm dia 92 350mm dia 93 400mm dia 94 450mm dia 95 500mm dia 96 Scour Valve 100 mm dia 97 Supply of under ground sluice value type firehydrant consisting of 80 mm dia sluice valve,80mm dia tail pieces, 80mm dia duck foot bend and 63 mm dia standard makes iron coupling with cap and etc. Complete conforming to latest/relevent I.S.specifications including all taxes and insurance. 98 Supply of 20 mm dia screwed down type air valve with gun metal seat, F.O.R. destination,including all taxes and insurance. 99 20 mm dia 100 CartingoffollowingsizesD.I.D/FSluicevalve andspecialsfromdepartmentalstoretositeof work and lowering them into the trenches, fixing inpositionandjointingthemwithpipelinesand testing etc. complete (including supply of jointing materials) 101 D.I.D/F Sluice Valve 102 80mm dia 103 100mm dia 104 125mm dia 105 150mm dia 106 200mm dia 107 250mm dia 108 300mm dia 109 350mm dia 110 400mm dia 111 450mm dia 112 500mm dia 113 Scour Valve 80 mm dia 114 Carting of 80 mm dia flanged fire hydrant to the site of works, lowering them into already prepared trenches and fixing them in position including baring and threading the main etc. Complete including thr cost of bailing out of water, supply of jointing materials such as nut-bolts, rubber insertions, white lead etc. Including their testing complete. 115 Carting from site store the 20 mm dia screwed down air valves, to the site of works, lowring them into already prepared trenches and fixing them in position including boring and threading the main etc. Complete and including the cost of bailing out of water , supply of jointing materials such as nut-bolts, rubber insertions, white lead etc.Including their testing complete. 116 Supply of all type materials and construct following chamber as per type design with supply of all labour, T & P etc. complete. 117 Masonry Type 118 Surface Box Type 119 Fire Hydrant Chamber 120 Air Valve Chamber 121 ScourValve Chamber 122 Dismantlingoffollowingtyperoadandstacking of useful material and temporary reinstatement of road with old materials etc. complete. 123 CC Road 124 Bituminous Road 125 B.O.E Road 126 Interlocking Road 127 Reinstatement of following type road and stacking of useful material and temporary reinstatement of road with old materials etc. complete. 128 CC RoadC.C. Road (with 125 mm PCC base of 1:4:8 cement: coarse sand: 40 mm Stone Aggregate and 125 mm Cement Concrete course of 1:1.5:3 cement: coarse sand: 20 mm Stone Aggregate) 129 Bituminous Road Bituminous Road Non PWD stretch as perspecification.1.granular sub-base With material conforming to Grade-I (size range 75 mm to 0.075 mm ) having CBR Value-25 125 mm layer thickness.2.granular sub-base With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBR Value-25 125 mm layer thickness.3. Providing, laying, Spreading & Compacting graded stone aggregateto wet mix macadam. (150 mm thickness)4. Providing & applying PrimeCoat with medium bitumen VG 10 on prepared surfacespreading primer at the rate of 0.75 Kg./Sqm.5.P/L of 40mm thick DBM with 100-120 TPH batch type HMP Producing and Avg. Output of 75 TPH using crushed aggt. Of specified grading premixed with bituminous binder VG 30 @ 3.5 %5.P/L of 30mm thick BC with 100-120 TPH batch type HMP Producing and Avg. Output of 75 TPH using crushed aggt. Of specified grading premixed with bituminous binder VG 30 @ 5.5 %6.Providing and laying seal coat over prepared surface of road with bitumen heated in bitumen boiler fitted with the spray set spraying using 98 kg of bitumen of grade VG - 10 and blinding surface with 0.90 cum of stone aggregate of 6.7 mm size7. Providing all necessary barricating and road painting work. 130 Bituminous Road PWDBituminous Road Bituminous Road on PWD stretch as per PWD specification.1.granular sub-base With material conforming to Grade-I (size range 75 mm to 0.075 mm ) having CBR Value-25 125 mm layer thickness.2.granular sub-base With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBR Value-25 125 mm layer thickness.3. Providing, laying, Spreading & Compacting graded stone aggregateto wet mix macadam. (150 mm thickness)4. Providing & applying PrimeCoat with medium bitumen VG 10 on prepared surfacespreading primer at the rate of 0.75 Kg./Sqm.5.P/L of 50mm thick DBM with 100-120 TPH batch type HMP Producing and Avg. Output of 75 TPH using crushed aggt. Of specified grading premixed with bituminous binder VG 30 @ 3.5 %5.P/L of 40mm thick BC with 100-120 TPH batch type HMP Producing and Avg. Output of 75 TPH using crushed aggt. Of specified grading premixed with bituminous binder VG 30 @ 5.5 %6.Providing and laying seal coat over prepared surface of road with bitumen heated in bitumen boiler fitted with the spray set spraying using 98 kg of bitumen of grade VG - 10 and blinding surface with 0.90 cum of stone aggregate of 6.7 mm size7. Providing all necessary barricating and road painting work. 131 B.O.E. Surface (Assuming 40% new brick and 60% old bricks used) 132 Interlocking Surface( 40 % New interlocking tile 80 mm thick M 35 Grade and 60 % old serviceable tiles , Palin cement concrete in 75 mm thickness 1:6:12 cement :sand: 40 mm coarse stone aggregate in base.) 133 Provision for crossings of nalas & culvert includingsiftingoftelephonecablesetc.Along the alignment of pipeline including supply of C.I. tytonpipeand specialsetc.complete.(3.5M. Wide Road) 134 Provision forInstallation of ductpipesby Augerboringmethodincludingmakingofentry andexitpitsupto3mtrdepth,allrelatedcivil works like excavation etc. lowering of pipe segmentsinthejackingpit,layingjointingof pipeline through jacking process as per the instruction of Engineer-in-charge all complete. 135 Road Crossing through trenchless technique 136 Road Crossing through HDD methode (upto 350 mm) 137 Sand Filling 138 Interconnection of new pipeline with existing pipeline including trenching,jointing,testing etc complete. PVC/HDPE to HDPE 139 Interconnection of new pipeline with existing pipeline including trenching,jointing,testing etc complete. DI/CI to DI upto 350 mm dia including supply of all meterial labour T&P required for making of joints and interconnections. 140 Construction of booster pump rooms including all required material labour T&P as per approved drawing and desigen plinth area rate. 141 Boundary Wall Gate and approchroad and site devlopment 142 Construction of Boundary Wall including Supply all materials, labour, T&P etc. required for proper completion of work as per type design. 143 Supplyandfixing3.6M&1.20MwideMSGatewith pillersincludingfabrication andsupplyofsteeland construction of boundary pillarsetc. completefor pump house 144 Provideallmaterials,labour,T&Petc.Requiredfor propercompletionofworkandconstructInterlocking Tiles approach road, laid dry and joints intact with coarse sand mortar including preparation of base etc. 145 Drain inside water works campus 146 Provide all materials labour, T&P etc. complete and construction of One Set staff quarter for operators & chaukidar as per departmental type design and drawing 147 Construction ofMaster Control Station. Building shall be RCC framed structure including all amenities like water supply, drainage, fire fighting, electrical fittings.required fall cellings/ wall panneling including all required furniturefor 10 persons in confrence rooms and other officers room as per standerd All specification shall be conforming to PWD/CPWD/C&DS building specification. 148 Construction ofRecharging Unit of ground water by rain water in water works sites as per the drawingor approved by Engineer in charge including supply of all materials, labour, T&P etc. required for proper completion of work. 149 HOUSE CONNECTION IN NEW PIPE LINE 150 Materials 151 20 mm dia (OD) HDPE pipe (12.5 KG/CM2) 152 15 mm dia (OD) GI pipe Class- B 153 Providing & supplying of clamp saddle (MS saddle for DI Pipe and Electrofusion Saddle For HDPE Pipe) for House service connections shall be of fastened strap type with threaded outlet for service connection.Clamp saddle shall be suitable for nominal size of distribution mains pipe line. The strap shall be elastomer coated ( insulated) type for firm grip on pipe as well as to protect the coating on the pipe and to insulate the unidentical metals. The saddle shall be single strap type up to pipe size of NB 600 and service outlet 15mm. Fasteners shall be of threaded nut bolt washer type. The sealing between the saddle and mains shall be obtained by using a profiled elastomer seal matching to the curvature of the pipe. The seal shall be elastomer type, suitable for all potable water application. The material of construction of the body, straps, fasteners etc. shall be non-corrosive material sucha as engineering plastic (PE/PP) or stainless steel of a combination of both and shall ne inclusive of all cost such as testing,inspection charges, transporation up to site, transit, insurance, loading, unloading, stacking etc. complete. 154 90 to 110 NB x 15 mm 155 140 to 160 NB x 15 mm 156 200 to 250 NB x 15 mm 157 300 to 500 NB x 15 mm 158 Labour 159 Making ferrule connection in. Distribution mainswith saddle piece, service connections, fittings, and fixing of G.M. Ferrule of 15 mm size inculding tapping the main and.cutting threading and fitting GI pipe and specials including supply of all binding materials such as white lead and teflon tape including making hole in wall and plastering the same with mortar including cost of mortar and also including the cost of crossing the drain including all labour, T&P complete as per direction of EIC 160 Dismantlingoffollowingtyperoadandstacking of useful material and temporary reinstatement of road with old materials etc. complete. 161 CC Road 162 Bituminous Road 163 B.O.E Road 164 Interlocking Road 165 Reinstatement of following type road and stacking of useful material and temporary reinstatement of road with old materials etc. complete. 166 CC RoadC.C. Road (with 125 mm PCC base of 1:4:8 cement: coarse sand: 40 mm Stone Aggregate and 125 mm Cement Concrete course of 1:1.5:3 cement: coarse sand: 20 mm Stone Aggregate) 167 Bituminous RoadBituminous Road Bituminous Road Non PWD stretch as perspecification.1.granular sub-base With material conforming to Grade-I (size range 75 mm to 0.075 mm ) having CBR Value-25 125 mm layer thickness.2.granular sub-base With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBR Value-25 125 mm layer thickness.3. Providing, laying, Spreading & Compacting graded stone aggregateto wet mix macadam. (150 mm thickness)4. Providing & applying PrimeCoat with medium bitumen VG 10 on prepared surfacespreading primer at the rate of 0.75 Kg./Sqm.5.P/L of 40mm thick DBM with 100-120 TPH batch type HMP Producing and Avg. Output of 75 TPH using crushed aggt. Of specified grading premixed with bituminous binder VG 30 @ 3.5 %5.P/L of 30mm thick BC with 100-120 TPH batch type HMP Producing and Avg. Output of 75 TPH using crushed aggt. Of specified grading premixed with bituminous binder VG 30 @ 5.5 %6.Providing and laying seal coat over prepared surface of road with bitumen heated in bitumen boiler fitted with the spray set spraying using 98 kg of bitumen of grade VG - 10 and blinding surface with 0.90 cum of stone aggregate of 6.7 mm size7. Providing all necessary barricating and road painting work. 168 Bituminous Road PWD Bituminous Road on PWD stretch as per PWD specification.1.granular sub-base With material conforming to Grade-I (size range 75 mm to 0.075 mm ) having CBR Value-25 125 mm layer thickness.2.granular sub-base With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBR Value-25 125 mm layer thickness.3. Providing, laying, Spreading & Compacting graded stone aggregateto wet mix macadam. (150 mm thickness)4. Providing & applying PrimeCoat with medium bitumen VG 10 on prepared surfacespreading primer at the rate of 0.75 Kg./Sqm.5.P/L of 50mm thick DBM with 100-120 TPH batch type HMP Producing and Avg. Output of 75 TPH using crushed aggt. Of specified grading premixed with bituminous binder VG 30 @ 3.5 %5.P/L of 40mm thick BC with 100-120 TPH batch type HMP Producing and Avg. Output of 75 TPH using crushed aggt. Of specified grading premixed with bituminous binder VG 30 @ 5.5 %6.Providing and laying seal coat over prepared surface of road with bitumen heated in bitumen boiler fitted with the spray set spraying using 98 kg of bitumen of grade VG - 10 and blinding surface with 0.90 cum of stone aggregate of 6.7 mm size7. Providing all necessary barricating and road painting work. 169 B.O.E. Surface (Assuming 40% new brick and 60% old bricks used) 170 Interlocking Surface ( 40 % New interlocking tile 80 mm thick M 35 Grade and 60 % old serviceable tiles , Palin cement concrete in 75 mm thickness 1:6:12 cement :sand: 40 mm coarse stone aggregate in base.) 171 Construction of TW for 1200/1100 LPM 172 TRANSPORTATION 173 Transportation of rig machineincluding Loading , unloading, Erection, Dismantling & labour etc complete in all respect . 174 Transportation of 250psi compressor including Loading , unloading, Erection, Dismantling & labour etc complete in all respect . 175 Transportation of 3 cusec op unit including Loading , unloading, Erection, Dismantling & labour etc complete in all respect . 176 Transportation of TubewellL Assemblyincluding Loading , unloading with labour etc complete in all respect . 177 CONSTRUCTION OF TUBE WELL (DRILLING) As per IS 2800 (Part I & II) 178 DC Drilling upto 200M 179 Logging of Bore 180 Drilling of 600mm dia bore from G.L. to 47 m BGL. 181 Drilling of 500mm dia bore from 47 m BGL to 100m BGL. 182 Drilling of 500mm dia bore from 101m BGL to 165m BGL. 183 LOWERING OF TUBE WELL ASSEMBLY AND SHROUDING OF T.W. BY GRAVEL- 184 Welding and lowering of TW Assembly (including electrodes welding set and generator etc. required for completion of work) as per following : Lowering of 300mm X 200mm dia (tube well assembly in bore hole and shrouding of pea gravel between annular space of bore hole and T.W. assembly from G.L. to 150m BGL. 185 Lowering of 300mm dia MSERW 7.1mm thick plain pipe from GL to 42 m BGL. 186 Lowering of 200mm dia MSERW plain/slotted pipe 7.1mm thick from 42m BGL to 100m BGL. 187 Lowering of 200mm dia MSERW plain/slotted pipe 7.1mm thick from 101m BGL to 150m BGL. 188 TUBE WELL: ASSEMBLY (As per IS 4270, IS 8110) 189 M.S. Tubewell assembly with all required parts like plain pipe, slotted pipe (as required upto 50% of plain pipes) well cap, bail pliug, clamp, reducer, centre guide, support structure etc as required & as per typed design complete in all respect. 190 300mm dia size MSERW housing pipe 7.1mm thick including with 1 no 300 X200mm dia M.S reducer 16mm thick, 1 noM.S. well cap 12mm thick , 10 no M.S. ring 100X12mm thick, M.S. S/I clamp ,T.W. Support (I Section) etc comp in all respect . 191 200mm dia MSERW 7.1mm thick plain /slotted pipe including with 20 no M.S ring 100X12mmthick , 1 noM.S. bail plug , 10 no center guide etc comp in all respect. 192 PEA-GRAVEL (As per IS 4097) 193 1.60mm to 4.80mm size pea-gravel of Lalkuwan quarry duly screened, washed and proper stackingat site. 194 DEVELOPMNET OF TUBE WELL 195 Development of tube well by 250 PSI air compressor 196 Development of tube well by 3 cusec O.P. Unit 197 Development of tube well by 3 cusec O.P. Unit. 198 TEST 199 Chemical and bacteriological test. 200 Construction of TW for 800 LPM 201 TRANSPORTATION 202 Transportation of rig machineincluding Loading , unloading, Erection, Dismantling & labour etc complete in all respect . 203 Transportation of 250psi compressor including Loading , unloading, Erection, Dismantling & labour etc complete in all respect . 204 Transportation of 3 cusec op unit including Loading , unloading, Erection, Dismantling & labour etc complete in all respect . 205 Transportation of TubewellL Assemblyincluding Loading , unloading with labour etc complete in all respect . 206 CONSTRUCTION OF TUBE WELL (DRILLING) As per IS 2800 (Part I & II) 207 DC Drilling upto 200M 208 Logging of Bore 209 Drilling of 600mm dia bore from G.L. to 65 m BGL. 210 Drilling of 500mm dia bore from 65 m BGL to 100m BGL. 211 Drilling of 500mm dia bore from 101m BGL to 165m BGL. 212 LOWERING OF TUBE WELL ASSEMBLY AND SHROUDING OF T.W. BY GRAVEL- 213 Welding and lowering of TW Assembly (including electrodes welding set and generator etc. required for completion of work) as per following : Lowering of 200mm X 150mm dia (tube well assembly in bore hole and shrouding of pea gravel between annular space of bore hole and T.W. assembly from G.L. to 150m BGL. 214 Lowering of 200mm dia MSERW 7.1mm thick plain pipe from GL to 60m BGL. 215 Lowering of 150mm dia MSERW plain/slotted pipe 7.1mm thick from 60m BGL to 100m BGL. 216 Lowering of 150mm dia MSERW plain/slotted pipe 7.1mm thick from 101m BGL to 150m BGL. 217 TUBE WELL: ASSEMBLY (As per IS 4270, IS 8110) 218 M.S. Tubewell assembly with all required parts like plain pipe, slotted pipe (as required upto 50% of plain pipes) well cap, bail pliug, clamp, reducer, centre guide, support structure etc as required & as per typed design complete in all respect. 219 200mm dia size MSERW housing pipe 7.1mm thick including with 1 no 200 X150mm dia M.S reducer 16mm thick, 1 noM.S. well cap 12mm thick , 10 no M.S. ring 100X12mm thick, M.S. S/I clamp ,T.W. Support (I Section) etc comp in all respect . 220 150mm dia MSERW 7.1mm thick plain /slotted pipe including with 20 no M.S ring 100X12mmthick , 1 noM.S. bail plug , 10 no center guide etc comp in all respect. 221 PEA-GRAVEL (As per IS 4097) 222 1.60mm to 4.80mm size pea-gravel of Lalkuwan quarry duly screened, washed and proper stackingat site. 223 DEVELOPMNET OF TUBE WELL 224 Development of tube well by 250 PSI air compressor 225 Cutting of T.W. cover by gas cutter, re-welding of T.W. cover by Electric welding after complete development of work. 226 Development of tube well by 3 cusec O.P. Unit 227 Cutting of housing cover by gas cutter 228 Development of tube well by 3 cusec O.P. Unit. 229 Re-welding of Tube well cover by Electric welding 230 TEST 231 Chemical and bacteriological test. 232 Construction of TW for 700 LPM 233 TRANSPORTATION 234 Transportation of rig machineincluding Loading , unloading, Erection, Dismantling & labour etc complete in all respect . 235 Transportation of 250psi compressor including Loading , unloading, Erection, Dismantling & labour etc complete in all respect . 236 Transportation of 3 cusec op unit including Loading , unloading, Erection, Dismantling & labour etc complete in all respect . 237 Transportation of TubewellL Assemblyincluding Loading , unloading with labour etc complete in all respect . 238 CONSTRUCTION OF TUBE WELL (DRILLING) As per IS 2800 (Part I & II) 239 DC Drilling upto 200M 240 Logging of Bore 241 Drilling of 600mm dia bore from G.L. to 47 m BGL. 242 Drilling of 500mm dia bore from 47 m BGL to 100m BGL. 243 Drilling of 500mm dia bore from 101m BGL to 165m BGL. 244 LOWERING OF TUBE WELL ASSEMBLY AND SHROUDING OF T.W. BY GRAVEL- 245 Welding and lowering of TW Assembly (including electrodes welding set and generator etc. required for completion of work) as per following : Lowering of 300mm X 150mm dia (tube well assembly in bore hole and shrouding of pea gravel between annular space of bore hole and T.W. assembly from G.L. to 150m BGL. 246 Lowering of 300mm dia MSERW 7.1mm thick plain pipe from GL to 42m BGL. 247 Lowering of 150mm dia MSERW plain/slotted pipe 7.1mm thick from 42m BGL to 100m BGL. 248 Lowering of 150mm dia MSERW plain/slotted pipe 7.1mm thick from 101m BGL to 150m BGL. 249 TUBE WELL: ASSEMBLY (As per IS 4270, IS 8110) 250 M.S. Tubewell assembly with all required parts like plain pipe, slotted pipe (as required upto 50% of plain pipes) well cap, bail pliug, clamp, reducer, centre guide, support structure etc as required & as per typed design complete in all respect. 251 300mm dia size MSERW housing pipe 7.1mm thick including with 1 no 300 X150mm dia M.S reducer 16mm thick, 1 noM.S. well cap 12mm thick , 10 no M.S. ring 100X12mm thick, M.S. S/I clamp ,T.W. Support (I Section) etc comp in all respect . 252 150mm dia MSERW 7.1mm thick plain /slotted pipe including with 20 no M.S ring 100X12mmthick , 1 noM.S. bail plug , 10 no center guide etc comp in all respect. 253 PEA-GRAVEL (As per IS 4097) 254 1.60mm to 4.80mm size pea-gravel of Lalkuwan quarry duly screened, washed and proper stackingat site. 255 DEVELOPMNET OF TUBE WELL 256 Development of tube well by 250 PSI air compressor 257 Development of tube well by 3 cusec O.P. Unit 258 Development of tube well by 3 cusec O.P. Unit. 259 TEST 260 Chemical and bacteriological test. 261 Pumping Plant & Instrumentation Including Servo Stablizer and Chlorinating Plant For New/Existing Tubewells 262 SITC of 1200 LPM submersible clear water pumping plant ( suitable head as per site condition and direction of engineer in charge) suitable to operate on 415+ %5 volt, 50 Hz, 3 phase A.C. supply (as per IS 8034-1989) with 150 mm dia column pipe 24 meter,150 mm dia NRV,150 mm dia CI D/F Bend 90 Degree,150 mm dia CI A/F Tee, 150 mm dia D/F pipe (1.5 m long 2 nos. and 1 m long 1 no.), earthing, painting, Toolset, stabilizer, wiring of pump house internal and external, chainpully block , and all pumping plant accessories with nut bolts and rubber packing etc. 263 SITC of 800 LPM submersible clear water pumping plant ( suitable head as per site condition and direction of engineer in charge) suitable to operate on 415+ %5 volt, 50 Hz, 3 phase A.C. supply (as per IS 8034-1989) with 100 mm dia column pipe 24 meter,100 mm dia NRV,100 mm dia CI D/F Bend 90 Degree,100 mm dia CI A/F Tee, 100 mm dia D/F pipe (1.5 m long 2 nos. and 1 m long 1 no.), earthing, painting, Toolset, stabilizer, wiring of pump house internal and external, chainpully block , and all pumping plant accessories with nut bolts and rubber packing etc. 264 SCADA compatable chlorinatingSystem 265 Supply & Erection of Servo Stabilizer of 15 KVA 266 Supply & Erection of Servo Stabilizer of 20 KVA 267 Supply & Erection of Servo Stabilizer of 30KVA 268 Supply & Erection of Servo Stabilizer of 40 KVA 269 CE / UL certified Intelligent smart energy meter 270 Motor OperatedActuator having positioning card with Sluice Valve (150mm) 271 Motor OperatedActuator having positioning card with Sluice Valve (100mm) 272 CE / UL certified Electromagneticflowmeter of size:150mm 273 CE / UL certified Electromagneticflowmeter of size:100mm 274 Digital Soft starter (7.5 KW) 275 Digital Soft starter (15 - 22KW) 276 Digital Soft starter (22 -30KW) 277 Digital Soft starter (30 -45KW) 278 Auto phase reversal unit with inbuilt time delay & enclosure conforming to IEC: 60947-1 & IEC:60947-b-1) (100 Amps) 279 CE / UL certified Hydrostatatic type sub soil water level transmitter 280 CE / UL certified Pressure Transmitter 281 CE / UL certified Surge protector for control panel 282 CE / UL certified 7 HMI touchscreen suitable to communicate with PLC/RTU, for local display & control of process parameters 283 Control panel with IP 54 protection, industrial grade from all equipments (separate for control (24V) and power equipments. 284 Complete Cabling for tubewell including all power & control cables of all equipment at pumphouse and OHT 285 Suppy and Installation of Suitable Size Armored Cable including copper lugs etc. complete work. 286 Internal electrification of pump house and chlorinating room. 287 SITC ofSCADA And Automation for New/Existing TWs 288 Fully Automation of T/W through SCADA complete in all respect e.g. supply installationtesting of all required RTU, wireless communication device, control panel, PLC, Programming,software, Licences, wiring etc complete in all respect including mobile based app development and interconnection with LCS,MCS central control room Barabanki & central control room Lucknow as per 24 x 7 water supply requirement. 289 Pumping Plant & Instrumentation Of CWR Zone 1 290 V.T. Pump- Motor Set 291 1900 LPM 40M head Clear Water 1450 RPM,surfacedischarge,self water lubricated, Bottom Suction with 150 mm dia size & 6 M long column Assembly ( Column Pipeshaft & Rubber spider) Discharge head, Top shaft, rachet to prevent reverse rotation, suitable to couple with 3 phase 4 Pole, Vertical hollow shaft1450 RPM squirrel cage 400 V±10% 50 Hz, AC, Motor etc. (or suitable head, H.P, RPM of pump motor & size & length of coloumn pipes as per site condition and direction of engineer in charge) 292 Starter 293 Provision of Digital Soft Starter to operate Upto 35 HP motor(or suitable Capacity as per site condition and direction of engineer in charge) at 0.4KV +10%3phase,50Hz. A.C. and to control the above motors. It shall comprise of all protection devicesas per latest I.S.S. specifications. 294 L.T. Switchgear Panel Board 295 Provision of 1 no. panelextensible typeswitchboard suitable for 0.4 KV3 phase 50 HZ. A.C. in cubical pattern, floor mountingcompletewith insulatedbus bars of suitable size forrequiredload. The switch board shall consist of the following : a. Oneno.Incoming Panelcomprisingof100AmpsMCCB indoor vertical isolation horizontally drawouttype withrelays as per ISS.Panelwill be comprisingof voltmeterwith selector switch, power factor meter,frequencymeter. KWH meter and ammetercomplete with selector switch, motor protection relay etc to operate 03 nos. 35 H.P. motor(or suitable Capacity as per site condition and direction of engineer in charge). . b. 3 Nos. outgoing panelsfor pumping plants. Each panel of 100Amps capacity MCCB with ammeter and C.T.with selector switch, KW meter, single phasing preventer, capacitor etc to operate 03 nos. 35 H.P. motor. c. 2 No. outgoing panels for misc. work comprising of 100Amp MCCB. 296 Provision and laying of PVC armoured Power cables of requiredsizes with earthing material.for internal wiring i.e Panel to Starters and from Starters to Motors 297 Delivery pipes and specials as per details given below (or suitable size as per site condition and direction of engineer in charge): 150 mm size individual delivery and 250 mm size common delivery with jointing material, valves, Tee, bends etc.a. 150 mm dia Detachable Joint-3 Nosb. 150 mm dia Bend- 3 Nosc. 150 X 250 mm Tee- 3 Nos d. 250 mm Reflux Valve-1 Nos.e. 250 mm dia Duckfoot Bend-1 Nos.f. 250 mm dia Common Header-15 M g. 250 mm dia Blind Flange-1 No 298 Provision of MS Girder for pump base etc. 299 Chukkered Plate and Grills to cover the Gaps between Girder and Adjacent Pumps 300 Internal electrification of Pump House (CWR), Pannel roomand campus with Light & Fan wiring and& other Necessary works. 301 Supply of Electro menhanical type chlorinating plant 0 to 30 LPHcapacity pump set Suitable for 500 Kg./Cm2 working pressure to feedsodiumhypochloridesolutioncomplete ste, Sodium Hypochloride liquid is used in this type of chlorinator which contains 120 gms of chlorine in 1000 ml Quantity Confirming quality Manegment System Standard NS-EN ISO 9001-2000 302 H.O.T. crane of 3 Tones capacity , Lift 4.5 Mtr 303 Testing of pumps & other equipment at work site 304 Painting of equipment with two coats. 305 CE / UL certified Intelligent smart energy meter 306 Motor Operatedsluice valve with Actuator for Pumps(150mm)(or suitable size as per site condition and direction of engineer in charge) 307 Motor Operatedsluice valve with Actuator for Common Header (250mm)(or suitable size as per site condition and direction of engineer in charge) 308 Electromagneticflowmeter of size: 250mm for common header(or suitable size as per site condition and direction of engineer in charge) 309 Auto phase reversal unit with inbuilt time delay & enclosure conforming to IEC: 60947-1 & IEC:60947-b-1) (160 Amps) 310 CE / UL certifiedRadar type Level Transmitter for CWR 311 CE / UL certifiedSmart Pressure Transmitter 312 CE / UL certified Surge protector for control panel 313 CE / UL certified 7 HMI touchscreen suitable to communicate with PLC/RTU, for local display & control of process parameters 314 Complete Cabling for ZPS including all power & control cable of all equipments at ZPS and OHT 315 Control panel with IP 54 protection, industrial grade fro all equipments (separate for control (24V) and power equipments. 316 Installation, commissioning & testing 317 Pumping Plant & Instrumentation Of CWR Zone 2 318 V.T. Pump- Motor Set 319 2700 LPM 40M head Clear Water 1450 RPM, surfacedischarge,self water lubricated, Bottom Suction with 200 mm dia size 6 M long column Assembly ( Column Pipeshaft & Rubber spider) Discharge head, Top shaft, rachet to prevent reverse rotation, suitable to couple with 3 phase 4 Pole, Vertical hollow shaft1450 RPM squirrel cage 400 V±10% 50 Hz, AC, Motor etc. (or suitable head, H.P, RPM of pump motor & size & length of coloumn pipes as per site condition and direction of engineer in charge) 320 Starter 321 Provision of Digital Soft Starter to operate Upto 40 HP motor(or suitable Capacity as per site condition and direction of engineer in charge) at 0.4KV +10%3phase,50Hz. A.C. and to control the above motors. It shall comprise of all protection devicesas per latest I.S.S. specifications. 322 L.T. Switchgear Panel Board 323 Provision of 1 no. panelextensible typeswitchboard suitable for 0.4 KV3 phase 50 HZ. A.C. in cubical pattern, floor mountingcompletewith insulatedbus bars of suitable size forrequiredload. The switch board shall consist of the following : a. Oneno.Incoming Panelcomprisingof100AmpsMCCB indoor vertical isolation horizontally drawouttype withrelays as per ISS.Panelwill be comprisingof voltmeterwith selector switch, power factor meter,frequencymeter. KWH meter and ammetercomplete with selector switch, motor protection relay etc to operate 03 nos. 40 H.P. motor(or suitable Capacity as per site condition and direction of engineer in charge).. b. 3 Nos. outgoing panelsfor pumping plants. Each panel of 100Amps capacity MCCB with ammeter and C.T.with selector switch, KW meter, single phasing preventer, capacitor etc to operate 03 nos. 40 H.P. motor. c. 2 No. outgoing panels for misc. work comprising of 100Amp MCCB. 324 Provision and laying of PVC armoured Power cables of requiredsizes with earthing material.for internal wiring i.e Panel to Starters and from Starters to Motors 325 Delivery pipes and specials as per details given below(or suitable size as per site condition and direction of engineer in charge) : 200 mm size individual delivery and 250 mm size common delivery with jointing material, valves, Tee, bends etc. a. 200 mm dia Detachable Joint-3 Nosb. 200 mm dia Bend- 3 Nos c. 200 X 250 mm Tee- 3 Nos d. 250 mm Reflux Valve-1 Nos.e. 250 mm dia Duckfoot Bend-1 Nos.f. 250 mm dia Common Header-15 Mg. 250 mm dia Blind Flange-1 No 326 Provision of MS Girder for pump base etc. 327 Chukkered Plate and Grills to cover the Gaps between Girder and Adjacent Pumps 328 Internal electrification of Pump House (CWR), Pannel roomand campus with Light & Fan wiring and& other Necessary works. 329 Supply of Electro menhanical type chlorinating plant 0 to 30 LPHcapacity pump set Suitable for 500 Kg./Cm2 working pressure to feedsodiumhypochloridesolutioncomplete ste, Sodium Hypochloride liquid is used in this type of chlorinator which contains 120 gms of chlorine in 1000 ml Quantity Confirming quality Manegment System Standard NS-EN ISO 9001-2000 330 H.O.T. crane of 3 Tones capacity , Lift 4.5 Mtr 331 Testing of pumps & other equipment at work site 332 Painting of equipment with two coats. 333 CE / UL certified Intelligent smart energy meter 334 Motor Operatedsluice valve with Actuator for Pumps(200mm)(or suitable size as per site condition and direction of engineer in charge) 335 Motor Operatedsluice valve with Actuator for Common Header (250mm)(or suitable size as per site condition and direction of engineer in charge) 336 Electromagneticflowmeter of size: 250mm for common header(or suitable size as per site condition and direction of engineer in charge) 337 Auto phase reversal unit with inbuilt time delay & enclosure conforming to IEC: 60947-1 & IEC:60947-b-1) (160 Amps) 338 CE / UL certifiedRadar type Level Transmitter for CWR 339 CE / UL certifiedSmart Pressure Transmitter 340 CE / UL certified Surge protector for control panel 341 CE / UL certified 7 HMI touchscreen suitable to communicate with PLC/RTU, for local display & control of process parameters 342 Complete Cabling for ZPS including all power & control cable of all equipments at ZPS and OHT 343 Control panel with IP 54 protection, industrial grade fro all equipments (separate for control (24V) and power equipments. 344 Installation, commissioning & testing 345 Pumping Plant & Instrumentation Of CWR Zone 3 346 V.T. Pump- Motor Set 347 1900 LPM 40M head Clear Water 1450 RPM,surfacedischarge,self water lubricated, Bottom Suction with150 mm dia & 6 M long column Assembly ( Column Pipeshaft & Rubber spider) Discharge head, Top shaft, rachet to prevent reverse rotation, suitable to couple with 3 phase 4 Pole, Vertical hollow shaft1450 RPM squirrel cage 400 V±10% 50 Hz, AC, Motor etc. (or suitable head, H.P, RPM of pump motor & size & length of coloumn pipes as per site condition and direction of engineer in charge) 348 Starter 349 Provision of Digital Soft Starter to operate Upto 35 HP motor(or suitable Capacity as per site condition and direction of engineer in charge)at 0.4KV +10%3phase,50Hz. A.C. and to control the above motors. It shall comprise of all protection devicesas per latest I.S.S. specifications. 350 L.T. Switchgear Panel Board 351 Provision of 1 no. panelextensible typeswitchboard suitable for 0.4 KV3 phase 50 HZ. A.C. in cubical pattern, floor mountingcompletewith insulatedbus bars of suitable size forrequiredload. The switch board shall consist of the following : a. Oneno.Incoming Panelcomprisingof100AmpsMCCB indoor vertical isolation horizontally drawouttype withrelays as per ISS.Panelwill be comprisingof voltmeterwith selector switch, power factor meter,frequencymeter. KWH meter and ammetercomplete with selector switch, motor protection relay etc to operate 03 nos. 35 H.P. motor(or suitable Capacity as per site condition and direction of engineer in charge). . b. 3 Nos. outgoing panelsfor pumping plants. Each panel of 100Amps capacity MCCB with ammeter and C.T.with selector switch, KW meter, single phasing preventer, capacitor etc to operate 03 nos. 35 H.P. motor. c. 2 No. outgoing panels for misc. work comprising of 100Amp MCCB. 352 Provision and laying of PVC armoured Power cables of requiredsizes with earthing material.for internal wiring i.e Panel to Starters and from Starters to Motors 353 Delivery pipes and specials as per details given below(or suitable size as per site condition and direction of engineer in charge) : 150 mm size individual delivery and 250 mm size common delivery with jointing material, valves, Tee, bends etc. a. 150 mm dia Detachable Joint-3 Nosb. 150 mm dia Bend- 3 Nosc. 150 X 250 mm Tee- 3 Nos d. 250 mm Reflux Valve-1 Nos. e. 250 mm dia Duckfoot Bend-1 Nos. f. 250 mm dia Common Header-15 Mg. 250 mm dia Blind Flange-1 No 354 Provision of MS Girder for pump base etc. 355 Chukkered Plate and Grills to cover the Gaps between Girder and Adjacent Pumps 356 Internal electrification of Pump House (CWR), Pannel roomand campus with Light & Fan wiring and& other Necessary works. 357 Supply of Electro menhanical type chlorinating plant 0 to 30 LPHcapacity pump set Suitable for 500 Kg./Cm2 working pressure to feedsodiumhypochloridesolutioncomplete ste, Sodium Hypochloride liquid is used in this type of chlorinator which contains 120 gms of chlorine in 1000 ml Quantity Confirming quality Manegment System Standard NS-EN ISO 9001-2000 358 H.O.T. crane of 3 Tones capacity , Lift 4.5 Mtr 359 Testing of pumps & other equipment at work site 360 Painting of equipment with two coats. 361 CE / UL certified Intelligent smart energy meter 362 Motor Operatedsluice valve with Actuator for Pumps(150mm) (or suitable size as per site condition and direction of engineer in charge) 363 Motor Operatedsluice valve with Actuator for Common Header (250mm) (or suitable size as per site condition and direction of engineer in charge) 364 Electromagneticflowmeter of size: 250mm for common header (or suitable size as per site condition and direction of engineer in charge) 365 Auto phase reversal unit with inbuilt time delay & enclosure conforming to IEC: 60947-1 & IEC:60947-b-1) (160 Amps) 366 CE / UL certifiedRadar type Level Transmitter for CWR 367 CE / UL certifiedSmart Pressure Transmitter 368 CE / UL certified Surge protector for control panel 369 CE / UL certified 7 HMI touchscreen suitable to communicate with PLC/RTU, for local display & control of process parameters 370 Complete Cabling for ZPS including all power & control cable of all equipments at ZPS and OHT 371 Control panel with IP 54 protection, industrial grade fro all equipments (separate for control (24V) and power equipments. 372 Installation, commissioning & testing 373 Pumping Plant & Instrumentation Of CWR Zone 4 374 V.T. Pump- Motor Set 375 2200 LPM 40M head Clear Water 1450 RPM, surfacedischarge,self water lubricated, Bottom Suction with 200 mm dia size 6 M long column Assembly ( Column Pipeshaft & Rubber spider) Discharge head, Top shaft, rachet to prevent reverse rotation, suitable to couple with 3 phase 4 Pole, Vertical hollow shaft1450 RPM squirrel cage 400 V±10% 50 Hz, AC, Motor etc. (or suitable head, H.P, RPM of pump motor & size & length of coloumn pipes as per site condition and direction of engineer in charge) 376 Starter 377 Provision of Digital Soft Starter to operate Upto 35 HP motor(or suitable Capacity as per site condition and direction of engineer in charge) at 0.4KV +10%3phase,50Hz. A.C. and to control the above motors. It shall comprise of all protection devicesas per latest I.S.S. specifications. 378 L.T. Switchgear Panel Board 379 Provision of 1 no. panelextensible typeswitchboard suitable for 0.4 KV3 phase 50 HZ. A.C. in cubical pattern, floor mountingcompletewith insulatedbus bars of suitable size forrequiredload. The switch board shall consist of the following : a. Oneno.Incoming Panelcomprisingof100AmpsMCCB indoor vertical isolation horizontally drawouttype withrelays as per ISS.Panelwill be comprisingof voltmeterwith selector switch, power factor meter,frequencymeter. KWH meter and ammetercomplete with selector switch, motor protection relay etc to operate 03 nos. 35 H.P. motor(or suitable Capacity as per site condition and direction of engineer in charge).b. 3 Nos. outgoing panelsfor pumping plants. Each panel of 100Amps capacity MCCB with ammeter and C.T.with selector switch, KW meter, single phasing preventer, capacitor etc to operate 03 nos. 35 H.P. motor. c. 2 No. outgoing panels for misc. work comprising of 100Amp MCCB. 380 Provision and laying of PVC armoured Power cables of requiredsizes with earthing material.for internal wiring i.e Panel to Starters and from Starters to Motors 381 Delivery pipes and specials as per details given below(or suitable size as per site condition and direction of engineer in charge) : 200 mm size individual delivery and 250 mm size common delivery with jointing material, valves, Tee, bends etc. a. 200 mm dia Detachable Joint-3 Nosb. 200 mm dia Bend- 3 Nos c. 200 X 250 mm Tee- 3 Nos d. 250 mm Reflux Valve-1 Nos.e. 250 mm dia Duckfoot Bend-1 Nos. f. 250 mm dia Common Header-15 Mg. 250 mm dia Blind Flange-1 No 382 Provision of MS Girder for pump base etc. 383 Chukkered Plate and Grills to cover the Gaps between Girder and Adjacent Pumps 384 Internal electrification of Pump House (CWR), Pannel roomand campus with Light & Fan wiring and& other Necessary works. 385 Supply of Electro menhanical type chlorinating plant 0 to 30 LPHcapacity pump set Suitable for 500 Kg./Cm2 working pressure to feedsodiumhypochloridesolutioncomplete ste, Sodium Hypochloride liquid is used in this type of chlorinator which contains 120 gms of chlorine in 1000 ml Quantity Confirming quality Manegment System Standard NS-EN ISO 9001-2000 386 H.O.T. crane of 3 Tones capacity , Lift 4.5 Mtr 387 Testing of pumps & other equipment at work site 388 Painting of equipment with two coats. 389 CE / UL certified Intelligent smart energy meter 390 Motor Operatedsluice valve with Actuator for Pumps(200mm)(or suitable size as per site condition and direction of engineer in charge) 391 Motor Operatedsluice valve with Actuator for Common Header (250mm)(or suitable size as per site condition and direction of engineer in charge) 392 Electromagneticflowmeter of size: 250mm for common header(or suitable size as per site condition and direction of engineer in charge) 393 Auto phase reversal unit with inbuilt time delay & enclosure conforming to IEC: 60947-1 & IEC:60947-b-1) (160 Amps) 394 CE / UL certifiedRadar type Level Transmitter for CWR 395 CE / UL certifiedSmart Pressure Transmitter 396 CE / UL certified Surge protector for control panel 397 CE / UL certified 7 HMI touchscreen suitable to communicate with PLC/RTU, for local display & control of process parameters 398 Complete Cabling for ZPS including all power & control cable of all equipments at ZPS and OHT 399 Control panel with IP 54 protection, industrial grade fro all equipments (separate for control (24V) and power equipments. 400 Installation, commissioning & testing 401 Pumping Plant & Instrumentation Of CWR Zone 7 402 V.T. Pump- Motor Set 403 1500 LPM 40M head Clear Water 1450 RPM,surfacedischarge,self water lubricated, Bottom Suction with150 mm dia & 6 M long column Assembly ( Column Pipeshaft & Rubber spider) Discharge head, Top shaft, rachet to prevent reverse rotation, suitable to couple with 3 phase 4 Pole, Vertical hollow shaft1450 RPM squirrel cage 400 V±10% 50 Hz, AC, Motor etc. (or suitable head, H.P, RPM of pump motor & size & length of coloumn pipes as per site condition and direction of engineer in charge) 404 Starter 405 Provision of Digital Soft Starter to operate Upto 35 HP motor at 0.4KV +10%3phase,50Hz. A.C. and to control the above motors. It shall comprise of all protection devicesas per latest I.S.S. specifications. 406 L.T. Switchgear Panel Board 407 Provision of 1 no. panelextensible typeswitchboard suitable for 0.4 KV3 phase 50 HZ. A.C. in cubical pattern, floor mountingcompletewith insulatedbus bars of suitable size forrequiredload. The switch board shall consist of the following :a. Oneno.Incoming Panelcomprisingof100AmpsMCCB indoor vertical isolation horizontally drawouttype withrelays as per ISS.Panelwill be comprisingof voltmeterwith selector switch, power factor meter,frequencymeter. KWH meter and ammetercomplete with selector switch, motor protection relay etc to operate 03 nos. 35 H.P. motor(or suitable Capacity as per site condition and direction of engineer in charge).. b. 3 Nos. outgoing panelsfor pumping plants. Each panel of 100Amps capacity MCCB with ammeter and C.T.with selector switch, KW meter, single phasing preventer, capacitor etc to operate 03 nos. 35 H.P. motor. c. 2 No. outgoing panels for misc. work comprising of 100Amp MCCB. 408 Provision and laying of PVC armoured Power cables of requiredsizes with earthing material.for internal wiring i.e Panel to Starters and from Starters to Motors 409 Delivery pipes and specials as per details given below(or suitable size as per site condition and direction of engineer in charge) : 150 mm size individual delivery and 250 mm size common delivery with jointing material, valves, Tee, bends etc. a. 150 mm dia Detachable Joint-3 Nosb. 150 mm dia Bend- 3 Nosc. 150 X 200 mm Tee- 3 Nos d. 200 mm Reflux Valve-1 Nos.e. 200 mm dia Duckfoot Bend-1 Nos. f. 200 mm dia Common Header-15 Mg. 200 mm dia Blind Flange-1 No 410 Provision of MS Girder for pump base etc. 411 Chukkered Plate and Grills to cover the Gaps between Girder and Adjacent Pumps 412 Internal electrification of Pump House (CWR), Pannel roomand campus with Light & Fan wiring and& other Necessary works. 413 Supply of Electro menhanical type chlorinating plant 0 to 30 LPHcapacity pump set Suitable for 500 Kg./Cm2 working pressure to feedsodiumhypochloridesolutioncomplete ste, Sodium Hypochloride liquid is used in this type of chlorinator which contains 120 gms of chlorine in 1000 ml Quantity Confirming quality Manegment System Standard NS-EN ISO 9001-2000 414 H.O.T. crane of 3 Tones capacity , Lift 4.5 Mtr 415 Testing of pumps & other equipment at work site 416 Painting of equipment with two coats. 417 CE / UL certified Intelligent smart energy meter 418 Motor Operatedsluice valve with Actuator for Pumps(150mm)(or suitable size as per site condition and direction of engineer in charge) 419 Motor Operatedsluice valve with Actuator for Common Header (200mm)(or suitable size as per site condition and direction of engineer in charge) 420 Electromagneticflowmeter of size: 200mm for common header(or suitable size as per site condition and direction of engineer in charge) 421 Auto phase reversal unit with inbuilt time delay & enclosure conforming to IEC: 60947-1 & IEC:60947-b-1) (100 Amps) 422 CE / UL certifiedRadar type Level Transmitter for CWR 423 CE / UL certifiedSmart Pressure Transmitter 424 CE / UL certified Surge protector for control panel 425 CE / UL certified 7 HMI touchscreen suitable to communicate with PLC/RTU, for local display & control of process parameters 426 Complete Cabling for ZPS including all power & control cable of all equipments at ZPS and OHT 427 Control panel with IP 54 protection, industrial grade fro all equipments (separate for control (24V) and power equipments. 428 Installation, commissioning & testing 429 Pumping Plant & Instrumentation Of CWR Zone 8 430 V.T. Pump- Motor Set 431 2500 LPM 40M head Clear Water 1450 RPM, surfacedischarge,self water lubricated, Bottom Suction with 200 mm dia size 6 M long column Assembly ( Column Pipeshaft & Rubber spider) Discharge head, Top shaft, rachet to prevent reverse rotation, suitable to couple with 3 phase 4 Pole, Vertical hollow shaft1450 RPM squirrel cage 400 V±10% 50 Hz, AC, Motor etc. (or suitable head, H.P, RPM of pump motor & size & length of coloumn pipes as per site condition and direction of engineer in charge) 432 Starter 433 Provision of Digital Soft Starter to operate Upto 40 HP motor(or suitable Capacity as per site condition and direction of engineer in charge) at 0.4KV +10%3phase,50Hz. A.C. and to control the above motors. It shall comprise of all protection devicesas per latest I.S.S. specifications. 434 L.T. Switchgear Panel Board 435 Provision of 1 no. panelextensible typeswitchboard suitable for 0.4 KV3 phase 50 HZ. A.C. in cubical pattern, floor mountingcompletewith insulatedbus bars of suitable size forrequiredload. The switch board shall consist of the following : a. Oneno.Incoming Panelcomprisingof100AmpsMCCB indoor vertical isolation horizontally drawouttype withrelays as per ISS.Panelwill be comprisingof voltmeterwith selector switch, power factor meter,frequencymeter. KWH meter and ammetercomplete with selector switch, motor protection relay etc to operate 03 nos. 40 H.P. motor(or suitable Capacity as per site condition and direction of engineer in charge)..b. 3 Nos. outgoing panelsfor pumping plants. Each panel of 100Amps capacity MCCB with ammeter and C.T.with selector switch, KW meter, single phasing preventer, capacitor etc to operate 03 nos. 40 H.P. motor. c. 2 No. outgoing panels for misc. work comprising of 100Amp MCCB. 436 Provision and laying of PVC armoured Power cables of requiredsizes with earthing material.for internal wiring i.e Panel to Starters and from Starters to Motors 437 Delivery pipes and specials as per details given below(or suitable size as per site condition and direction of engineer in charge) : 200 mm size individual delivery and 250 mm size common delivery with jointing material, valves, Tee, bends etc. a. 200 mm dia Detachable Joint-3 Nosb. 200 mm dia Bend- 3 Nos c. 200 X 250 mm Tee- 3 Nos d. 250 mm Reflux Valve-1 Nos.e. 250 mm dia Duckfoot Bend-1 Nos.f. 250 mm dia Common Header-15 Mg. 250 mm dia Blind Flange-1 No 438 Provision of MS Girder for pump base etc. 439 Chukkered Plate and Grills to cover the Gaps between Girder and Adjacent Pumps 440 Internal electrification of Pump House (CWR), Pannel roomand campus with Light & Fan wiring and& other Necessary works. 441 Supply of Electro menhanical type chlorinating plant 0 to 30 LPHcapacity pump set Suitable for 500 Kg./Cm2 working pressure to feedsodiumhypochloridesolutioncomplete ste, Sodium Hypochloride liquid is used in this type of chlorinator which contains 120 gms of chlorine in 1000 ml Quantity Confirming quality Manegment System Standard NS-EN ISO 9001-2000 442 H.O.T. crane of 3 Tones capacity , Lift 4.5 Mtr 443 Testing of pumps & other equipment at work site 444 Painting of equipment with two coats. 445 CE / UL certified Intelligent smart energy meter 446 Motor Operatedsluice valve with Actuator for Pumps(200mm)(or suitable size as per site condition and direction of engineer in charge) 447 Motor Operatedsluice valve with Actuator for Common Header (250mm)(or suitable size as per site condition and direction of engineer in charge) 448 Electromagneticflowmeter of size: 250mm for common header(or suitable size as per site condition and direction of engineer in charge) 449 Auto phase reversal unit with inbuilt time delay & enclosure conforming to IEC: 60947-1 & IEC:60947-b-1) (160 Amps) 450 CE / UL certifiedRadar type Level Transmitter for CWR 451 CE / UL certifiedSmart Pressure Transmitter 452 CE / UL certified Surge protector for control panel 453 CE / UL certified 7 HMI touchscreen suitable to communicate with PLC/RTU, for local display & control of process parameters 454 Complete Cabling for ZPS including all power & control cable of all equipments at ZPS and OHT 455 Control panel with IP 54 protection, industrial grade fro all equipments (separate for control (24V) and power equipments. 456 Installation, commissioning & testing 457 Pumping Plant & Instrumentation Of CWRZone 10 458 V.T. Pump- Motor Set 459 2400 LPM 40M head Clear Water 1450 RPM, surfacedischarge,self water lubricated, Bottom Suction with 200 mm dia size 6 M long column Assembly ( Column Pipeshaft & Rubber spider) Discharge head, Top shaft, rachet to prevent reverse rotation, suitable to couple with 3 phase 4 Pole, Vertical hollow shaft1450 RPM squirrel cage 400 V±10% 50 Hz, AC, Motor etc. (or suitable head, H.P, RPM of pump motor & size & length of coloumn pipes as per site condition and direction of engineer in charge) 460 Starter 461 Provision of Digital Soft Starter to operate Upto 40 HP motor(or suitable Capacity as per site condition and direction of engineer in charge) at 0.4KV +10%3phase,50Hz. A.C. and to control the above motors. It shall comprise of all protection devicesas per latest I.S.S. specifications. 462 L.T. Switchgear Panel Board 463 Provision of 1 no. panelextensible typeswitchboard suitable for 0.4 KV3 phase 50 HZ. A.C. in cubical pattern, floor mountingcompletewith insulatedbus bars of suitable size forrequiredload. The switch board shall consist of the following : a. Oneno.Incoming Panelcomprisingof100AmpsMCCB indoor vertical isolation horizontally drawouttype withrelays as per ISS.Panelwill be comprisingof voltmeterwith selector switch, power factor meter,frequencymeter. KWH meter and ammetercomplete with selector switch, motor protection relay etc to operate 03 nos. 40 H.P. motor(or suitable Capacity as per site condition and direction of engineer in charge).. b. 3 Nos. outgoing panelsfor pumping plants. Each panel of 100Amps capacity MCCB with ammeter and C.T.with selector switch, KW meter, single phasing preventer, capacitor etc to operate 03 nos. 40 H.P. motor. c. 2 No. outgoing panels for misc. work comprising of 100Amp MCCB. 464 Provision and laying of PVC armoured Power cables of requiredsizes with earthing material.for internal wiring i.e Panel to Starters and from Starters to Motors 465 Delivery pipes and specials as per details given below(or suitable size as per site condition and direction of engineer in charge) : 200 mm size individual delivery and 250 mm size common delivery with jointing material, valves, Tee, bends etc. a. 200 mm dia Detachable Joint-3 Nosb. 200 mm dia Bend- 3 Nos c. 200 X 250 mm Tee- 3 Nos d. 250 mm Reflux Valve-1 Nos.e. 250 mm dia Duckfoot Bend-1 Nos.f. 250 mm dia Common Header-15 Mg. 250 mm dia Blind Flange-1 No 466 Provision of MS Girder for pump base etc. 467 Chukkered Plate and Grills to cover the Gaps between Girder and Adjacent Pumps 468 Internal electrification of Pump House (CWR), Pannel roomand campus with Light & Fan wiring and& other Necessary works. 469 Supply of Electro menhanical type chlorinating plant 0 to 30 LPHcapacity pump set Suitable for 500 Kg./Cm2 working pressure to feedsodiumhypochloridesolutioncomplete ste, Sodium Hypochloride liquid is used in this type of chlorinator which contains 120 gms of chlorine in 1000 ml Quantity Confirming quality Manegment System Standard NS-EN ISO 9001-2000 470 H.O.T. crane of 3 Tones capacity , Lift 4.5 Mtr 471 Testing of pumps & other equipment at work site 472 Painting of equipment with two coats. 473 CE / UL certified Intelligent smart energy meter 474 Motor Operatedsluice valve with Actuator for Pumps(200mm)(or suitable size as per site condition and direction of engineer in charge) 475 Motor Operatedsluice valve with Actuator for Common Header (250mm)(or suitable size as per site condition and direction of engineer in charge) 476 Electromagneticflowmeter of size: 250mm for common header(or suitable size as per site condition and direction of engineer in charge) 477 Auto phase reversal unit with inbuilt time delay & enclosure conforming to IEC: 60947-1 & IEC:60947-b-1) (160 Amps) 478 CE / UL certifiedRadar type Level Transmitter for CWR 479 CE / UL certifiedSmart Pressure Transmitter 480 CE / UL certified Surge protector for control panel 481 CE / UL certified 7 HMI touchscreen suitable to communicate with PLC/RTU, for local display & control of process parameters 482 Complete Cabling for ZPS including all power & control cable of all equipments at ZPS and OHT 483 Control panel with IP 54 protection, industrial grade fro all equipments (separate for control (24V) and power equipments. 484 Installation, commissioning & testing 485 Automation of CWR For All ZONEs 486 CE & UL approved manufacturer’s RTU/ PLC in IP 54 encloser suitable to communicate with GSM based modem unit with CPU and power supply with analog and digital parameter and features as specified, onefor each tubewellto store and transmit data on GSM backbone. RTU/PLC designed with logic to transfer data at multiple stations. G.S.M./G.P.R.S. based wireless communication with 4G Modem for RTU/ PLC Capable to transfer and gather data from remote sites to control stations, all accessories included with signal enhancer anteena made for pumping plant 487 Automation of All Zone OHT 488 Automation of existing/new OHT & associated infrastructure as per actual site requirement like existing/new Tubewells related valves, pressure transmitters,level sensors, chlorination system, OHT outlet flowmeter, OHT outlet acutator valves with positioning card,required RTU panel, control & power wiring, earthing including SITC /repairing of already existing equipments (in case of existing OHT)complete in all respect in a way to complete automation as per CPHEEO drink from tap mannual further associated guidelines. 489 DMA /ESR Automation for Zone-1 490 Survey, design asset mapping, SITC of following equipments along with other requied infrastucture/equipments as per requirements and guidelines of 24x7 water supply requirements. The job includes SITC of all required software and hardwares not mentioned elsewhere & min. 8 hrs battery backup.. 491 Double Solenoid Flow Control Valve 350 mm Dia 492 Pressure Transmitter 493 Mannual Pressure Transmitter 494 CE / UL certified Electromagnetic flowmeter of size 350 mm Dia 495 SCADA Compatible Chlorinating Plant 496 Design, SITC of Booster pumps asper 24 x 7 water supply requirements with 50% standby of peak water demand along with main piping and actuator valves and bypass arrangement,extra pressure transmiiter, VFD drive, PLC panel, TDS analyser, power and control wiring complete in all respect considering all DMAs 497 Resedual Chlorine Analyser 498 DMA /ESR Automation for Zone-2 499 Survey, design asset mapping, SITC of following equipments along with other requied infrastucture/equipments as per requirements and guidelines of 24x7 water supply requirements. The job includes SITC of all required software and hardwares not mentioned elsewhere & min. 8 hrs battery backup.. 500 Double Solenoid Flow Control Valve 250 mm 501 Double Solenoid Flow Control Valve 300 mm 502 Pressure Transmitter 503 Mannual Pressure Transmitter 504 CE / UL certified Electromagnetic flowmeter of size250 mm Dia 505 Design, SITC of Booster pumps asper 24 x 7 water supply requirements with 50% standby of peak water demand along with main piping and actuator valves and bypass arrangement,extra pressure transmiiter, VFD drive, PLC panel, TDS analyser, power and control wiring complete in all respect considering all DMAs 506 CE / UL certified Electromagnetic flowmeter of size 300 mm Dia 507 SCADA Compatible Chlorinating Plant 508 Resedual Chlorine Analyser 509 DMA /ESR Automation for Zone-3 510 Survey, design asset mapping, SITC of following equipments along with other requied infrastucture/equipments as per requirements and guidelines of 24x7 water supply requirements. The job includes SITC of all required software and hardwares not mentioned elsewhere & min. 8 hrs battery backup.. 511 Double Solenoid Flow Control Valve350 mm Dia 512 Pressure Transmitter 513 Mannual Pressure Transmitter 514 CE / UL certified Electromagnetic flowmeter of size 350 mm Dia 515 Design, SITC of Booster pumps asper 24 x 7 water supply requirements with 50% standby of peak water demand along with main piping and actuator valves and bypass arrangement,extra pressure transmiiter, VFD drive, PLC panel, TDS analyser, power and control wiring complete in all respect considering all DMAs 516 SCADA Compatible Chlorinating Plant 517 Resedual Chlorine Analyser 518 DMA /ESR Automation for Zone-4 519 Survey, design asset mapping, SITC of following equipments along with other requied infrastucture/equipments as per requirements and guidelines of 24x7 water supply requirements. The job includes SITC of all required software and hardwares not mentioned elsewhere & min. 8 hrs battery backup.. 520 Double Solenoid Flow Control Valve 200 mm dia 521 Double Solenoid Flow Control Valve 300 mm dia 522 Pressure Transmitter 523 Mannual Pressure Transmitter 524 CE / UL certified Electromagnetic flowmeter of size200 mm dia 525 Design, SITC of Booster pumps asper 24 x 7 water supply requirements with 50% standby of peak water demand along with main piping and actuator valves and bypass arrangement,extra pressure transmiiter, VFD drive, PLC panel, TDS analyser, power and control wiring complete in all respect considering all DMAs 526 CE / UL certified Electromagnetic flowmeter of size300 mm dia 527 SCADA Compatible Chlorinating Plant 528 Resedual Chlorine Analyser 529 DMA /ESR Automation for Zone-5 530 Survey, design asset mapping, SITC of following equipments along with other requied infrastucture/equipments as per requirements and guidelines of 24x7 water supply requirements. The job includes SITC of all required software and hardwares not mentioned elsewhere & min. 8 hrs battery backup.. 531 Double Solenoid Flow Control Valve 350 mm dia 532 Pressure Transmitter 533 Mannual Pressure Transmitter 534 CE / UL certified Electromagnetic flowmeter of size 350 mm dia 535 SCADA Compatible Chlorinating Plant 536 Resedual Chlorine Analyser 537 DMA /ESR Automation for Zone-6 538 Survey, design asset mapping, SITC of following equipments along with other requied infrastucture/equipments as per requirements and guidelines of 24x7 water supply requirements. The job includes SITC of all required software and hardwares not mentioned elsewhere & min. 8 hrs battery backup.. 539 Double Solenoid Flow Control Valve350 mm dia 540 Pressure Transmitter 541 Mannual Pressure Transmitter 542 CE / UL certified Electromagnetic flowmeter of size 350 mm dia 543 SCADA Compatible Chlorinating Plant 544 Resedual Chlorine Analyser 545 DMA /ESR Automation for Zone-7 546 Survey, design asset mapping, SITC of following equipments along with other requied infrastucture/equipments as per requirements and guidelines of 24x7 water supply requirements. The job includes SITC of all required software and hardwares not mentioned elsewhere & min. 8 hrs battery backup.. 547 Double Solenoid Flow Control Valve 548 Pressure Transmitter 549 Mannual Pressure Transmitter 550 CE / UL certified Electromagnetic flowmeter of size 551 Design, SITC of Booster pumps asper 24 x 7 water supply requirements with 50% standby of peak water demand along with main piping and actuator valves and bypass arrangement,extra pressure transmiiter, VFD drive, PLC panel, TDS analyser, power and control wiring complete in all respect considering all DMAs 552 SCADA Compatible Chlorinating Plant 553 Resedual Chlorine Analyser 554 DMA /ESR Automation for Zone-8 555 Survey, design asset mapping, SITC of following equipments along with other requied infrastucture/equipments as per requirements and guidelines of 24x7 water supply requirements. The job includes SITC of all required software and hardwares not mentioned elsewhere & min. 8 hrs battery backup.. 556 Double Solenoid Flow Control Valve250 mm dia 557 Double Solenoid Flow Control Valve300 mm dia 558 Pressure Transmitter 559 Mannual Pressure Transmitter 560 CE / UL certified Electromagnetic flowmeter of size 250mm dia 561 CE / UL certified Electromagnetic flowmeter of size 300mm dia 562 SCADA Compatible Chlorinating Plant 563 Resedual Chlorine Analyser 564 DMA /ESR Automation for Zone-9 565 Survey, design asset mapping, SITC of following equipments along with other requied infrastucture/equipments as per requirements and guidelines of 24x7 water supply requirements. The job includes SITC of all required software and hardwares not mentioned elsewhere & min. 8 hrs battery backup.. 566 Double Solenoid Flow Control Valve300 mm 567 Pressure Transmitter 568 Mannual Pressure Transmitter 569 CE / UL certified Electromagnetic flowmeter of size 300 mm 570 Design, SITC of Booster pumps asper 24 x 7 water supply requirements with 50% standby of peak water demand along with main piping and actuator valves and bypass arrangement,extra pressure transmiiter, VFD drive, PLC panel, TDS analyser, power and control wiring complete in all respect considering all DMAs 571 SCADA Compatible Chlorinating Plant 572 Resedual Chlorine Analyser 573 DMA /ESR Automation for Zone-10 574 Survey, design asset mapping, SITC of following equipments along with other requied infrastucture/equipments as per requirements and guidelines of 24x7 water supply requirements. The job includes SITC of all required software and hardwares not mentioned elsewhere & min. 8 hrs battery backup.. 575 Double Solenoid Flow Control Valve 200 mm dia 576 Double Solenoid Flow Control Valve 300 mm dia 577 Pressure Transmitter 578 Mannual Pressure Transmitter 579 CE / UL certified Electromagnetic flowmeter of size 200 mm dia 580 CE / UL certified Electromagnetic flowmeter of size 300 mm dia 581 SCADA Compatible Chlorinating Plant 582 Resedual Chlorine Analyser 583 DMA /ESR Automation for Zone-11 584 Survey, design asset mapping, SITC of following equipments along with other requied infrastucture/equipments as per requirements and guidelines of 24x7 water supply requirements. The job includes SITC of all required software and hardwares not mentioned elsewhere & min. 8 hrs battery backup.. 585 Double Solenoid Flow Control Valve350 mm dia 586 Pressure Transmitter 587 Mannual Pressure Transmitter 588 CE / UL certified Electromagnetic flowmeter of size350 mm dia 589 SCADA Compatible Chlorinating Plant 590 Resedual Chlorine Analyser 591 DMA /ESR Automation for Zone-12 592 Survey, design asset mapping, SITC of following equipments along with other requied infrastucture/equipments as per requirements and guidelines of 24x7 water supply requirements. The job includes SITC of all required software and hardwares not mentioned elsewhere & min. 8 hrs battery backup.. 593 Double Solenoid Flow Control Valve300 mm dia 594 Pressure Transmitter 595 Mannual Pressure Transmitter 596 Design, SITC of Booster pumps asper 24 x 7 water supply requirements with 50% standby of peak water demand along with main piping and actuator valves and bypass arrangement,extra pressure transmiiter, VFD drive, PLC panel, TDS analyser, power and control wiring complete in all respect considering all DMAs 597 CE / UL certified Electromagnetic flowmeter of size 300 mm dia 598 SCADA Compatible Chlorinating Plant 599 Resedual Chlorine Analyser 600 DMA /ESR Automation for Zone-13 601 Survey, design asset mapping, SITC of following equipments along with other requied infrastucture/equipments as per requirements and guidelines of 24x7 water supply requirements. The job includes SITC of all required software and hardwares not mentioned elsewhere & min. 8 hrs battery backup.. 602 Double Solenoid Flow Control Valve250 mm dia 603 Pressure Transmitter 604 Mannual Pressure Transmitter with Display 605 CE / UL certified Electromagnetic flowmeter of size 250 mm dia 606 SCADA Compatible Chlorinating Plant 607 Resedual Chlorine Analyser 608 DMA /ESR Automation for Zone-14 609 Survey, design asset mapping, SITC of following equipments along with other requied infrastucture/equipments as per requirements and guidelines of 24x7 water supply requirements. The job includes SITC of all required software and hardwares not mentioned elsewhere & min. 8 hrs battery backup.. 610 Double Solenoid Flow Control Valve250 mm dia 611 Pressure Transmitter 612 Mannual Pressure Transmitter with Display 613 CE / UL certified Electromagnetic flowmeter of size 250 mm dia 614 SCADA Compatible Chlorinating Plant 615 Resedual Chlorine Analyser 616 SITC of SCADA MCS 617 SITC of MCS SCADAfor each DMA of all Zones including TWs, CWR, ESR/OHT complete in all respect. (or as per site condition and direction of engineer in charge or as per CPHEEO manual Drink from Tap Dec.2024) 618 Sub Station OfCWR Zone 619 Design & SITC of electric substation for CWR including 02 Nos.(01 Working+01 Standby) Transformer, 11 KV HT swicthgear panel with 01 No incoming and 02 Nos. outgoing VCB alongwith LT control panel having sufficient No of ACB/MCCB of suitable size for actual site equipment reqiremwnts with electrical interlocks and complete power and control cabling works, APFC, earthing, lighting arrester, TPMO Switch, safety SITCs barbed wire, H-Pole, foundation/plinth, lighting, Rubber mating, internal, external electrification, laisioning from Discom, NOC from electrical safety department,testing & commisioning complete in all respect with all labour material & T&Ps having capacity 100KVA/160KVA, 11/0.415 KV 620 Trail & Run 621 Three Months Trial & Run OfTubewell & SCADA with all consumable items 622 Three Months Trial & Run OfCWR with all consumable items

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 21-10-2024 Clarification Other 29-10-2024

Key Value

Document Fees
INR 23600 /-
EMD
INR 13737000.0 /-
Tender Value
INR 173.37 Crore /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail