}

Tender For Etmadpur Nagar Palika Parishad Water Supply Scheme, Survey, Soil Investigation, Design, Supply Of All Materials, Labour, T&P Etc. Required For Construction, Erection, Completion, Testing & Commissioning Of Water Supply Works Such As Rcc Ohts, Z, agra-Uttar Pradesh

Government Departments has published Tender For Etmadpur Nagar Palika Parishad Water Supply Scheme, Survey, Soil Investigation, Design, Supply Of All Materials, Labour, T&P Etc. Required For Construction, Erection, Completion, Testing & Commissioning Of Water Supply Works Such As Rcc Ohts, Z. Submission Date for this Tender is 15-10-2024. Drainage Tenders in agra Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

45484805
Tender For Etmadpur Nagar Palika Parishad Water Supply Scheme, Survey, Soil Investigation, Design, Supply Of All Materials, Labour, T&P Etc. Required For Construction, Erection, Completion, Testing & Commissioning Of Water Supply Works Such As Rcc Ohts, Z
Open Tender
Indian
Uttar Pradesh
Agra
15-10-2024

Tender Documents

Tender Details

tender for Etmadpur Nagar Palika Parishad Water Supply Scheme, Survey, Soil investigation, Design, Supply of all materials, labour, T&P etc. required for construction, erection, completion, testing & commissioning of water supply works such as RCC OHTs, ZPSs/CWR cum Pumping Station, Rising main, Feeder main, Distribution System, SCADA Room, Chlorination room, Meter Room, Panel Room, Boundary Wall & Site development works etc. and other appurtenant works including SCADA and Automation as per specifications in tender document for Etmadpur Nagar Palika Parishad Water Supply Scheme. The scope of work also includes trial run of 3 months & defect liability period of 12 months for Civil works & 24 months for E/M works after completion of successful trial run. All completed and commissioned workunderEtmadpur Nagar Palika Parishad Water Supply Scheme shall be hand over to Nagar Palika Parishad Etmadpur, District-Agra after 3 month successful trial run period. Sl. No. Item Description 1 Design, Supply of all materials, labour, T&P etc required for construction of Intz type RCC Over Head Tank including various works like - Ventilator and Water level indicator, Lightening conductor, C.I. D/F Verticle pipes (Inlet Pipe, Outlet Pipe, Overflow Pipe & Washout Pipe), duck foot bend, puddle collers and bell mouths, Sluice valve on inlet, outlet & washout pipe and Valve Chamber, Bye-pass arrangement of OHT, Flooring withApran & Drain( min.100 mm thick PCC of 1:2:4 & 100 mm thick RCC of 1:1.5:3 with nominal reinforcement), Floor level shall be 60 cm above the finished ground level of Campus, Three coat apex painting over one coat primer of approved colour after finishing of RCC surface with grinder, repair of pin holes, unevenness., Railings- G.I. Pipe railing around stair case (both sides), balcony & top dome periphery, S.S ladder from opening of top dome to bottom dome, Stair case (Seperate two column basedRCC staircase and 1 m wide balcony with arrangement of M.S Gate and Jali for 600 KL OHT & 1.0 m wide stair case around OHT column for 250 kl OHT), Food grade epoxy coating of FOSROC / Ciba-Geigy or reputated brand on inside surface area of water container after testing for water tightness, of capacity and staging mentioned as under:For bidding purpose, bearing capacity of soil shall be considered as 8t/sq.m. Working design shall be based on the SBC determind after soil investigation / 8 tonne/sqm.Note :- The bid price of Over Head Tanks is to be submitted considering net safe allowable bearing capacity as 8 t/m2, keeping the minimum foundation depth to be 2.5 m below existing ground level at the site of work. The successful bidder will be required to investigate the soil bearing capacity. If net safe allowable bearing capacity is found to be equivalent or more than 8 t/m2, the design of OHT will be based on 8 t/m2 capacity. However, in case the net safe allowable bearing capacity is found to be below 8 t/m2, then the design of OHT will be based on the actual bearing capacity. 2 OHT of 600 kl capacity, 24 m stagingNai Basti Water Supply Zone-I 3 OHT of 250 kl capacity, 24m stagingIOCL Water Supply Zone-III 4 Design, supply of all material, labour, T&P etc. required for construction of Ractangular, R.C.C Clear Water Reservoir cum pump house including various works like 1 m wide stair case with stainless steel hand railing to go inside reservoir, sump below the pump house area, stainless steel railing over the R.C.C slab of reservoir, Granular texture finish on exterior surface of pump house, gantry beam, food grade epoxy coating of FOSROC / Ciba-Geigy or reputated brand on inside surface area of water container after testing for water tightness, of capacity mentioned as under:Note : The bid prices of Clear Water Reservoir / Pumping Stations are to be submitted considering the depth of excavation may extend up to 6 m BGL. 5 750 KL Zonal Pumping Station for Zone- I, Zone- II& Zone-III 6 Construction of Meter Room as per type design (Size - 4m x 4m x 4m) including supply of all materials, labour, T&P etc. required for proper completion of the work as per the directions of Engineer-in- charge. 7 Construction of Panel Room as per type design (Size - 5m x 5m x 4 m) including supply of all materials, labour, T&P etc. required for proper completion of the work as per the directions of Engineer-in- charge. 8 Construction of Chlorinating Room as per type design (Size - 6m x 4m x 4 m) including supply of all materials, labour, T&P etc. required for proper completion of the work as per the directions of Engineer-in- charge. 9 Construction of SCADA Control Room as per type design (Size - 10m x 4m x 4 m) including supply of all materials, labour, T&P etc. required for proper completion of the work as per the directions of Engineer-in- charge. 10 Supply of ISI mark DI K-9 and K-7 S&S pipes (push on joints) of following class and diameters inclusive of jointing material (Rubber gasket of EPDM Quality, Bend, Tee etc.) including all statutary duties and taxes, third party inspection charges, transit insurance, freight, transportation to store/ site of work, unloading, stacking etc. complete as directed by Engineer –in-charge. 11 D.I. Pipe Class-K9 12 300 mm dia 13 200mm dia 14 250mm dia 15 150mm dia 16 D.I. Pipe Class-K7 17 200 mm dia 18 250 mm dia 19 300 mm dia 20 350 mm dia 21 400 mm dia 22 Supply of High Density Polyethelene Pipes (HDPE(PN-6)/PE-100), conforming to IS 4984 / 14151 / 12786 / 13488 in coils/ standard lengths with nesessary jointing material like electro-fusion coupler, electro-fusion Tee, electro-fusion band, electro-fusion reducer, flanged joint, including all statutary duties and taxes, third party inspection charges, transit insurance, freight, transportation to store/ site of work, unloading & stacking the same in covered shade duly protecting from sunrays & rains, etc. complete as directed by Engineer –in-charge. 23 110 mm (HDPE(PN-6)/PE-100) 24 140 mm (HDPE(PN-6)/PE-100) 25 160 mm (HDPE(PN-6)/PE-100) 26 Earth work in excavation for pipeline trenches in following type of soils with lead upto 50M, refilling the soil as required, including depositing in layers not exceeding 150mm, watering and compaction to 95% of the Standard Proctor density, level dressing, including supply of all labour, T&P etc. required for proper completion of the work. 27 In ordinary soil 28 0 -1.5 29 Carting, lowering, laying and jointing with SBR ruber gasketsD.I. K-7/ D.I. K-9 pipes of following dia & pressure including all specials, to site of work, lowering them into trenches, laying true to alignment and gradient, in proper position, cutting of pipes, making of joints including cost of jointing materials and rubber rings, labour, T&P, including hydraulic testing etc. complete as directed by Engineer in-charge. It includes provision for making of alignment on city roads, making trial pits to investigate location of various under grounds services like telephone cables, electric cable, existing pipe lines and sewer lines etc. arrangements for diversion of traffic and associated works etc. with supply of all necessary equipment, materials, labour and T&P etc. complete required for completion of work. The trenches shall be properly barricaded and fenced off wherever necessary. Red flags and caution boards during day and red lights during night shall be displayed so as to avoid any accidents. Note : Only SBR Rubber gaskets to be used as per IS-5382 and IS- 12820. 30 D.I. Pipe Class-K9/K7 31 400 mm dia 32 350 mm dia 33 300 mm dia 34 250mm dia 35 200mm dia 36 150mm dia 37 Carting, lowering, laying of following dia of HDPE Pipe (PN-6)/PE-100 of following dia and requisite specials to site of work, lowering them into trenches, laying true to alignment and gradient, in proper position, cutting of pipes, making of joints including cost of jointing materials and rubber rings, labour, T&P, including hydraulic testing etc. complete as directed by Engineer in-charge.It includes provision for making of alignment on city roads, making trial pits to investigate location of various under grounds services like telephone cables, electric cable, existing pipe lines and sewer lines etc. arrangements for diversion of traffic and associated works etc. with supply of all necessary equipment, materials, labour and T&P etc. complete required for completion of work.The trenches shall be properly barricaded and fenced off wherever necessary. Red flags and caution boards during day and red lights during night shall be displayed so as to avoid any accidents. Note: Jointing between HDPE pipes and specials shall be done as per the latest IS: 7634 part II. Only Bar coded electro-fusion machine (Automatically Readable) that can read the bar code of the fittings automatically shall be used for jointing of HDPE pipe/fittings. 38 110 mm (HDPE(PN-6)/PE-100) 39 140 mm (HDPE(PN-6)/PE-100) 40 160 mm (HDPE(PN-6)/PE-100) 41 Supply of following types of D.I. valves confirming to the I.S. specification inclusive cost of jointing materials (Rubber gasket of EPDM Quality, dismantling joint or mechanical joint, Nut & Bolts etc.) including all statutary duties and taxes, third party inspection charges, transit insurance, freight, transportation to store/ site of work, unloading, stacking etc. complete as directed by Engineer –in-charge. 42 Electrically Operated DI D/F Sluice valve, PN 1.6 43 300 mm dia 44 Manually Operated DI D/F Sluice valve, PN 1.6 as per IS 14840 : 2000 45 125 mm 46 150 mm 47 200 mm 48 250 mm 49 100mm dia for Scour valve 50 Air valves as per IS 14845 : 2000 including Sluice valve of Isolation 51 50 mm 52 80 mm 53 100 mm dia 54 Fire Hydrant as per IS Code 908 : 1975 55 80 mm 56 Carting, lowering, laying, aligning, fixing in position and installation of following valves in pipe line including all material, labour, testing and commissioning as per direction of Engineer-in- charge. 57 Double flanged Ductile Iron Sluice valves as per IS 14840 : 2000 58 125 mm dia 59 150mm dia 60 200 mm dia 61 250 mm dia 62 300 mm dia 63 100mm dia for Scour valve 64 Air valves as per IS 14845 : 2000 65 50mm to 80 mm dia 66 100 mm dia 67 Fire Hydrant as per IS Code 908 : 1975 68 80 mm dia 69 Supply of all materials, labour, T&P etc required for construction of brick masnory chambers for valves mentioned below. It includes excavation, 100 mm thick PCC, brick work in 1:6, 12 mm thick plaster in 1:4 and precast RCC (M20 grade) slab of thickness 200 mm as per the directions of Engineer-in- charge. 70 Sluice valve Chamber 71 100mm to 250 mm(Size-1.3mx1.4mx1.625m) 72 300mm dia to 400 mm dia (Size-1.5m x 1.7m x 2.1m 73 Air Valve Chamber (Size-0.8m x 0.8m x 0.8m) 74 Scour Valve Chamber (Size-1.3m x 1.4m x 1.625m) 75 Fire Hydrant Chamber 76 Dismantling of following type of road surfaces for laying of pipe line and house connection work including sorting out of serviceable materials and disposal of unserviceable materials including supply of all materials, labour, T&P etc. required for proper completion of the work.The rates of dismantling of roads as mentioned below for different types of roads include the cutting of existing thickness of road either single or multiple layer of roads. No extra payment shall be made to the contractor for cutting multiple layers of roads. 77 Bituminious Road 78 Cement Concrete Road 79 Interlocking Tiles Road 80 Brick on edge Road (BOE) 81 Re-instatement of following type of road surfaces after laying of pipe line and house connection work including supply of all materials, T&P etc. requuired for proper completion of the work as per direction of engineer-in-charge. The quantity of re-instatement has been increased by thirty percent in the view of additional damaged of dismantled road due to traffic / vehicle movement. 82 Bitumen roadTYPE AConstruction of bitumen road as per UPPWD specification including supply of all materials, labour, T&P etc. required for proper completion of work as per following thickness:-GSB G-1 (One coat) (90-40 mm) = 12.5 cmG -2 (one coat) (45-63 mm) = 7.5 cmG - 3 (one coat) (22.5 - 53 mm) = 7.5 cmBM (One coat)= 7.5 cmSDBC (One coat)= 2.5 cm 83 TYPE BConstruction of bitumen road as per UPPWD specification including supply of all materials, labour, T&P etc. required for proper completion of work as per following thickness:-Bitumen Road (SDBC + Tack coat)SDBC (One coat)= 2.5 cmTack coat with bituminous emulsion (MS)= 0.25 kg/sqm(30% consider for over dismantling of existing road) 84 Cement Concrete RoadConstruction of Cement Concrete road including supply of all materials, labour, T&P etc. required for proper completion of work as per following thickness:-PCC = 100 mm,1:3:6 (cement, coarse sand & stone ballast of 20-40 mm) CC =100 mm, 1:1.5 :3 (cement, coarse sand & stone ballast of 16-20 mm) 85 C.C. Interlocking Tiles Road Type AConstruction of 80 mm tihck C.C. Interlocking Tile road including supply of all materials, labour, T&P etc. required for proper completion of work as per following thickness:-PCC = 100 mm,1:4:8 (cement, coarse sand & stone ballast of 20-40 mm)Sand= 30mm to 50mm thick local sand lair for preparation of surfaceTiles = 50% new + 50% old 86 BOE (Brick on Edge) RoadConstruction of BOE road including supply of all materials, labour, T&P etc. required for proper completion of work as per following thickness:-Ist class brick shall be used for reinstatement of BOE road.Brick = 50% new + 50% oldSand =15mm to 25mm thick local sand layer for preparation of surface 87 Providing and laying in position reinforced cement concrete (mix 1:2:4) for construction of thurst block at bends of feeder main, rising main & distribution system including batching, mixing, placing, vibrating, curing, formwork, finishing,including cost ofall material and labor, tools and plants required with transportation, loading, unloading,etc., complete for all leads and lifts etc required for proper completion of the work. 88 Providing H.Y.S.D steel reinforcement for reinforced cement concrete work including straightening, cutting, bending, hooking, placing in position, lapping and/ or welding wherever required, tying with binding wire and anchoring to the adjoining member wherever necessary as per design, including cost of materials and labor complete as per drawings. 89 Supply of all materials, labour, T&P etc. required for construction of following masonry type chambers as per type design. 90 Flow Meter Chambers 300mm dia to 400 mm dia (Size-1.7m x1.5m x 1.5m) 91 Disposal of surplus earth /unserviceable material, by mechanical transport including loading, transporting, unloading to approved municipal dumping ground for lead upto 10 km for all lifts, complete as per directions of Engineer-in-charge. 92 Supply of all material including all statutary duties and taxes, third party inspection charges, transit insurance, freight, transportation to store/ site of work, unloading, laying and installing MS casing and carrier pipe crossing the National Highway and other roads for following sizeswith trenchless technology by to correct line and level. The rate to include construction and removal of any jacking platforms, boring and jacking of pipe, removal of excavated material, jointing of casing sections, radiographic testing of joints, internal coating of casing pipe, providing HDPE spacers between the casing and carrier pipes, excavation of jacking and receiving pits, MS shoring/ shuttering, dewatering, 35 cm thick protection brick wall surrounding the pits for protection from entry of waste water of nearby drains, rain water or unwanted material for safety purpose, and backfilling of same to 95% of the standard Proctor density, etc., as indicated in the drawings and specifications.It includes supply ofM.S. pipe with approved quality material from TATA/SAIL, epoxy coating in 300 micron thickness on both in and outside, welding material etc. After successful completion of laying, contractor shall fix blind plate at both the flanged ends of carrier pipe with rubber gasket, nut-bolts. After completion of aforesaid activities, contractor shall dismantle the shoring/shuttering taking all measures in consideration for safety, filling of earth in both pits in layers duly compacted up to 95% of density, filling of local sand in 1.0 m thick layer below the road surface. For safety caution/ diversion board with reflectors, caution tape, red blinker lights for night, hard baricading, traffic diversion, drainage diversion and pumping if required and other necessary arrangements for proper completion of the work up to the satisfaction of Engineer-in-charge. 93 For 300 mm dia of Feeder MainCasing Pipe - 500 mm dia MS Pipe (10 mm thick)Carrier Pipe - 300 mm dia MS Pipe (6 mm thick) 94 For 150mm dia of Rising Main (Zone-III):-Casing Pipe - 400 mm dia MS Pipe (10 mm thick)Carrier Pipe - 150 mm dia MS Pipe (6 mm thick) 95 Repairing / Shifting of existing water supply house connection due to falling in alignment of pipe line including supply of all materials, labour, T&P etc. required for proper completion of the work. 96 Provision for crossing of Nalas for laying of pipe line using HDPE casing pipe of suitable dia. and length including labour, T&P, necessary arrangement for diversion & pumping of water if required, barricading etc required for proper completion of work as per directions of engineer-in-charge. 97 0.3 - 0.5 m (Clear span) 98 0.5 - 1.0 m (Clear span) 99 1.0 - 1.5 m (Clear span) 100 1.5 - 2.0 m (Clear span) 101 Repairing of drain/ public ramp/other miscellaneous structures which are coming in alignment of pipe line and damaged during the laying of pipe line including supply of all materials, labour, T&P etc. required for proper completion of the work. 102 Brick masonry in cement mortar 1:4 103 12mm thick plaster in cement mortar 1:4 104 RCC M-20 (including MS work) 105 Providing and making water supply house connection from distribution pipe line of following diameters using 20 mm dia pipe (HDPE pipe (PE 100/ PN 12.5) below ground and medium class GI pipe above ground), saddle (electro-fusion tapping saddle for making connection with HDPE distribution pipeline, DI strap saddle, ferrule,for making connection with distribution pipeline other than HDPE), compression fittings (FTA, MTA etc.), ball valve, specials, including supply of all materials, labour, T&P etc. required for proper completion of the work. It also includes excavation, refilling of pit required for making house connection. 106 For 110 mm dia 107 For 125mm - 160mm dia 108 For 180 mm - 250mm dia 109 Construction of compound wall comprising of RCC Columns @ 3.0m c/c distance with beam at plinth and top, brick work in 1:4 of as per type design including supply of all material, labour, T& P etc complete. 110 Supply and fixing 3.60 m wide MS main gate & 1.0 m wide a wicket gate with RCC Columns as per type design & drawing including primer and painting, meterial, labour, T&P etc all complete. 111 Providing and laying in position reinforced cement concrete (mix 1:2:4) for construction of drain, size 250 mm x 250 mm, over PCC 1:4:8, including batching, mixing, placing, vibrating, curing, formwork, finishing,including cost ofall material and labor, tools and plants required with transportation, steel,loading, unloading,etc., complete for all leads and liftsand as per specifications etc required for proper completion of the work. 112 Construction of following types of Road/ flooring for development of CWR / OHT campus required as per site condition 113 C.C. Interlocking Tiles Road Construction of C.C. Interlocking Tile road including supply of all materials, labour, T&P etc. required for proper completion of work as per following thickness:-PCC = 100 mm,1:4:8 (cement, coarse sand & stone ballast of 20-40 mm)Sand= 50 mm thick local sand lair for preparation of surfaceTiles = 100% new Note : 100 mm thick rubber moulded interlocking tile shall be used for construction of interlocking tile road. 114 Repair of old OHT, Seepage, Water Proofing works, Indicator board, Lightening Consductor, Manhole etc. All tank related works as per direction of Engineer in Charge. 115 E&M Works 116 Providing, erecting, commissioning and giving test and trial of Clear Water VT pumps , water lubricated type and having following duty point,operating speed including providing and fixing ISMB grating etc, including Vertical hollow /solid shaft squirrel gauge induction motor (IS 325) of rating suitable for the above pumps continuous rated TEFC/ SPDP type with class F insulation for operation in AC 3-phase/ 50Hz (+/- 5%), 415 volt (+/- 10%)running with the speed of pump noted above and with inbuilt thrust bearing assembly capable of taking of the entire load and non reverse ratchet assembly etc complete. The motor rating noted above is the minimum and shall be such that it should never be overloaded when the pump works at the MWL condition and shall be 10% over and above the maximum HP absorbed by the pump. The motor offered should be energy efficient to have maximum efficiency at high powerfactor. Separate thrust bearing assembly could also be supplied to takeup the down load. 1500 RPM as per detailed specifications. 117 Etmadpur Zone-I :- Q= 1280 LPM, H=37m with suitable motor HP 118 Etmadpur Zone-II :- Q= 2500 LPM, H=34m, with suitable motor HP 119 Etmadpur Zone-III :- Q= 480 LPM, H=36m, with suitable motor HP 120 Providing, erecting, commissioning and giving test and trial of Horizontal split casing centrifugal booster pump motor set suited for variable frequency drive to regulate the discharge as per demand. 121 Etmadpur Zone-II Booster Pump : Q= 7700 LPM, H=5m, with suitable motor HP 122 Supply of double flangedDI short body pattern butterfly valvewith electrical actuator having integal starter and related hardware, including chair support, etc., conforming to IS 13095/BS EN 593, including transportation to site, loading, unloading, storage, guarding, and issuance to works as per specifications . 123 Etmadpur Zone-I :- 150 mm 124 Etmadpur Zone-II :- 200 mm 125 Etmadpur Zone-III :- 100 mm 126 Etmadpur Zone-II Booster Pump : 400 mm 127 Supply of double flanged,DI, short body sluice valves with electrical actuator having integal starter and related hardware conforming to IS 14846, including transportation to site, loading, unloading, storage, guarding, and issuance to works as per specifications .Common Header in mm 128 Etmadpur Zone-I :- 200 mm 129 Etmadpur Zone-II :- 250 mm 130 Etmadpur Zone-III :- 150 mm 131 Etmadpur Zone-II Booster Pump : 400 mm 132 Supply of flanged DI Kinetic air valve including isolated sluice valve and related hardware conforming to IS 14845 / C512, including transportation to site, loading, unloading, storage, guarding, and issuance to works as per specifications .Common Header in mm 133 Etmadpur Zone-I :- 80 mm 134 Etmadpur Zone-II :- 80 mm 135 Etmadpur Zone-III :- 80 mm 136 Etmadpur Zone-II Booster Pump : 80 mm 137 Supply of dismantling joints and related hardware, including transportation to site, loading, unloading, storage, guarding, and issuance to works as per specifications . 138 Individual Header, mm 139 Etmadpur Zone-I :- 150 mm 140 Etmadpur Zone-II :- 200 mm 141 Etmadpur Zone-III :- 100 mm 142 Commonl Header, mm 143 Etmadpur Zone-I :- 200 mm 144 Etmadpur Zone-II :- 250 mm 145 Etmadpur Zone-III :- 150 mm 146 Etmadpur Zone-II Booster Pump : 400 mm 147 Providing and supplying ISI mark DI D/F reflux valves (non-returnvalves ) of following dia including all railway freight, inspection chargesunloding from railway wagon,loading into truck, transportation upto departmental stroes/ site,unloading, stacking etc. complete. Reflux valves as per I.S.5312 Part I(1984). 148 Etmadpur Zone-I :- 150 mm 149 Etmadpur Zone-II :- 200 mm 150 Etmadpur Zone-III :- 100 mm 151 Etmadpur Zone-II Booster Pump : 400 mm 152 Providing, errecting, commissioning and testing of non clog sump pump motor set havingpump discharge capacity of 30 LPS raw water with silt and mid at a total head of 30m with piping and other necessary arrangements. 153 Q=30LPS, H=30mwith suitable motor HP 154 Providing, fabricating, testing, transporting, and handling mild steelpipes and bendsas per IS 5504, IS 3589 and the specifications and drawings.The rate to include transportation of pipes to site, loading, unloading, storage, guarding, and issuance to works as per specifications. The rates shall be inclusive of Collecting materials from storage, loading, transporting, unloading, laying and jointing/welding pipe connections to correct line and level as per the specifications and drawings.The rate to includehoisting, lowering, marginal cutting wherever necessary, assembling, providing supports, thrust blocks, anchor blocks etc., as per specifications and drawings.The rate also includes testing of field joints . The rate shall also inclusive of internal and external epoxy coating and lining for corrosion protections as specified in the Specifications. 155 Indivisual Header, mm 156 Etmadpur Zone-I :- 150 mm 157 Etmadpur Zone-II :- 200 mm 158 Etmadpur Zone-III :- 100 mm 159 Commonl Header, mm 160 Etmadpur Zone-I :- 200 mm 161 Etmadpur Zone-II :- 250 mm 162 Etmadpur Zone-III :- 150 mm 163 Etmadpur Zone-II Booster Pump : 400 mm 164 Supply and errection of new Electrical Operated Crane (EOT) with chain pulley block complete3T and above 8 m upto 10 m span 165 Providing and supplying ISI mark Electromagnetic Flow meter of following dia including all railway freight, inspection charges unloading from railway wagon, loading into truck, transportation up to departmental stores / site, unloading, stacking etc. complete.Commonl Header 166 Etmadpur Zone-I :- 200 mm 167 Etmadpur Zone-II :- 250 mm 168 Etmadpur Zone-III :- 150 mm 169 Spetials, fittings, gauges, Saddle,Nuts Bolts washers etc, cost, Work includes making connection with existing pipes etc 170 Etmadpur Zone-I 171 Etmadpur Zone-II 172 Etmadpur Zone-III 173 Etmadpur Zone-II Booster Pump 174 SITC of SCADA Automation compatable Hypochloride dosing system -2 tanks of 1500 lt ,Diaphragm pump- 2 no,VFD , Control panel with all necessary allied works complete in all respect. 175 Designing, supplying, installing, commissioning and testing of pilot operated hydraulically controlled Flow limiting cum Altitute Control Valve for ESR Inlet with level controlling and flow limiting application which maintains aconstant downstream rate of flow. Also, closes on high reservoir level (FSL). opens when reservoir level drops with fixed set points inclusive of all accessories like integral Float arrrangement pressure gauge etc. complete as per specification. 176 Etmadpur Zone-I :- 200 mm 177 Etmadpur Zone-II :- 250 mm 178 Etmadpur Zone-III :- 150 mm 179 Electrical Works 180 Arrangement of 11 kV power suppy at Pumping Stationsincluding 11kV outdoor substation, pole structure, metering room, LA, CT, PT, disconnector, fuse, ACSR conductor, pin & disc insulators, indoor and outdoorCable Termination with heat Shrinkable jointing kits with all accessories including Lugs suitable as required as accepted standard complete, clamp & connectors with metering unit including steel structure as applicable as per approved single line diagram 181 Design, Supply, Installation, Testing and Commissioning of 11kV indoor HT Panel as per approved single line diagram pumping StationsIncommer Feeder- 01 No. - 3 O/C + 1 EF IDMT Characteristics Relays based Incommer control panel equiped with over current & earth fault relay with core balance C.T., master trip relay, instantaneous under voltage realy & Auxilliary relay etc.C.T.ratio suitable rating Dual core, Class-1 for measurement core & 5P10 for protection core & PT 11KV/110 VAC. KWH meter, power factor meter, frequency meter. Amp. meter 0-100A& volt meter 0 to12 KV. All relays required separately conventioal type 24 to 30 VDC, 110 VAC.Outgoing Feeder- 02 Nos. - Outgoing feeder control panel equiped withtriple pole 3 O/C + 1 E/F relay with IDMT & intantaneous characterisstics, mater trip relay & Auxilliary relay for Buchhloz alarm / trip, OTI alram / trip & WTI alram/trip, etc.C.T.ratio suitable rating, Class-1 for measurement core & 5P10 for protection core. 182 Design, Supply, Installation, Testing and Commissioning of 110V Ni-Cd battery, battery charger & DC distribution board and accessories suitable for above HT Panel. 183 Design, Supply, Installation, Testing and Commissioning of oil immersedOutdoor type Power distribution transformer 11/0.433 KV rating 100 KVA double wound with copperwinding, Level-2 or 3, vector group dyn 11, ONAN with offload tap changer operated for voltage variation + 5.0 % to - 10% at 07 tap positions in step of 2.5% complete with standard fitting & accessories complete in all respect. 184 Design, Supply, Installation, Testing and Commissioning of 415 V, Indoor Switch board PMCC panel (including 6 soft starters 2VFD, Lighting and Power arrangements) with neccessory and suitable rating of breaker, current transformer, ammeter, voltmeter, power factor meter, surg arrestor relay, UV / OV relay, frequency meter etc complete with all required material in all respect at Etmadpur CWR Pumping Station 185 Design, Supply, Installation, Testing and Commissioning of 415 V, APFC panel of suitable rating complete with required APFC relay and capacitor bank complete. 186 Complete lighting system including energy efficient lighting fixtures, lighting poles, wires, conduits, cables, and necessary accessories - external lighting 187 Complete lighting system including energy efficient lighting fixtures, lighting poles, wires, conduits, cables, utility sockets (3ph and 1ph.) and necessary accessories - internal lighting 188 Complete earthing / lightning protection system including earth electrode, earth strip, wires, junction box for test links, treated and non-treated earth pits, etc. with necessary accessories 189 Complete cabling system with LV power and control cables, cable trays, route marker, steel structure for cable trench, pipes and accessories 190 Complete cabling system with HV power and control cables, cable trays, route marker, steel structure for cable trench, pipes and accessories 191 Start stopPush Button Stations 192 AUTOMATION WORKS: Installation of Instrumentation and Control Equipment including, but not limited to, safe storage, protection, civil works, erection, installation, testing and commissioning required to complete the Works in all respects for the following equipment: 193 CE & UL approved manufacturers RTU/PLC suitable to communicate with GSM based modem unit with CPU and power supply with analog and digital parameter and features as specified for each tubewell & CWR to store and transmit data on GSM backbone. RTU/PLC designed with logic to transfer data at multiple stations as specified in tender technical specification sheet including Control panel with IP 54 protection industrial grade for all equipments (Separate for control (24 V) and power equipments) with CE / UL approved manufacturer’s Surge protector for Control Panel and CE / UL approved manufacturer’s 7 HMItouchscreen suitable to communicate with PLC/RTU, for local display & control of process parameters as specified in tender technical specification sheet . 194 GSM/GPRS based wireless communicationmodem for RTU/PLC capable to transfer and gather data from remote sites to control stations, all accessories included with signal enhancer anteena made for pumping plant as specified in tender technical specification sheet. 195 CE / UL Certified 3 KVA UPS with batteries as per specification mentioned in technical bid documents. 196 CE/UL approved manufacturers Intelligent smart energy meter with memory real time clock and 1 serial port integrated with R.T.U. as per spec mentioned in technical bid documents for all pumps. 197 CE / UL approved manufacturer’s Radartype Level Transmitter for CWR as specified in tender technical specification sheet 198 CE / UL approved manufacturer’s Pressure Transmitter in main header line of Pump as per specifications specified in tender technical specification sheet. 199 CE/UL surge protector for control panel 200 CE/UL Certified 7 HMI Touchscreen suitable to commuticate with PLC / RTU for loac display and control of process parameter. 201 Completecontrol cable of all equipments at ZPS 202 Control Panel with IP54 protection Indsutrial grade for all equipmets seprate for control (24 Volt) and power equipment. 203 Complete instrumentation earthing system including earth electrode, earth strip, wires, junction box for test links, treated and non-treated earth pits, etc. with necessary accessories 204 Security Surveillance IP Camera with Recorer 205 Instaallation, Testing & Commissioning 206 Trial Run for 3 Month 207 Automation of OHT 208 CE / UL approved manufacturer’s Radartype Level Transmitter for Overhead tank as specified in tender technical specification sheet 209 Motor operated Actuator for OHT delivery Valves DN 450 mm or suitable to OHT outlet dia 210 Complete cabling for OHT including all power and control cable of all equipments at OHTs.

Key Value

Document Fees
INR 23600 /-
EMD
INR 2750000.0 /-
Tender Value
Refer document

Attachment

FileName File Description File Size
Click here to download tender document Tender Notice 0 KB
Click here to download tender document Tender Document 0 KB
Click here to download tender document Tender Document 0 KB
Click here to download tender document Tender Document 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail