Tender For Addn/Altn Of Jco Md Accn Bldg No P-44 At Hajipir Enclave At Lgj Mil Station, Ganganagar-Rajasthan

Statutory Bodies & Commissions/Committees has published Tender For Addn/Altn Of Jco Md Accn Bldg No P-44 At Hajipir Enclave At Lgj Mil Station. Submission Date for this Tender is 19-10-2024. Electrical Maintenance Tenders in Ganganagar Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

45479179
Tender For Addn/Altn Of Jco Md Accn Bldg No P-44 At Hajipir Enclave At Lgj Mil Station
Open Tender
Indian
Rajasthan
Ganganagar
19-10-2024

Tender Documents

Tender Details

Tender For Addn/Altn Of Jco Md Accn Bldg No P-44 At Hajipir Enclave At Lgj Mil Station; 1 Demolition of cement concrete (unreinforced) in ground floor and paving n.exc 15cm in thickness (below or above ground level) and rubhis off from premises complete all as specified and directed by Engr-in-charge. 2 Demolition of Cement Concrete (reinforced) of any description and in any position not otherwise specifically provided for and rubhish off from premises complete all as specified and directed by Engr-in-charge. 3 Demolitionof brickwork or stone / boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc. but excluding ashlar facings, dressed stone work and precast concrete articles including cleaning and stacking serviceable brick for re use and balance removing rubbish from the site complete all as specified and as directed by Engineer-in-charge. 4 Taking down cement plaster from brick wall or concrete surfaces or ceiling including raking out joints, hacking for key & scrubbing down with water etc complete all as specified and directed. 5 M&L rendering 15 mm thick cement plaster on brick walls or concrete, surface in cm 1:6on wall and surface to be finished even andsmooth without using extra cement complete all as specified & directed 6 M&L for rendering 15 mm thick cement plaster on brick walls or concrete, surface in cm 1:4on wall and surface to be finished even andsmooth without using extra cement complete all as specified & directed 7 M & L for rendering 10 mm thick in cement mortar (1:4) on fair faces ofconcrete surfacesof ceiling finished even and smooth without using extra cement complete all as specified & directed. 8 M&L for two coats of oil bound distemper on newly plastered surfacesof walls over and including one coat of primer and 3mm thick wall care putty including preparation of surfaces complete all as specified and directed. 9 M&L for complete removal of existing treatment and two coats of oil bound distemper over 3 mm thick wall care putty onplastered surfaces of walls including preparation of surfaces complete all as specified and directed by Engineer-in-Charge. 10 M&L for 3 coats of white wash on newly plastered surfaces on ceiling incl preparation etc. complete all as specified and directed. 11 M&L for preparation of old surface and applying two coats of white wash on ceilingsurfaces complete all as specified and directed by Engineer-in-charge. 12 M&L for preparation of old surfaceand applying two coats of white wash on wall complete all as specified and directed by Engineer-in-charge. 13 M&L for preparation of new plastered and applying two coats of weather proof exterior emulsion paint (Apex ultima or equivalent) over a coat of primer over3 mm thick wall care putty complete all as specified and directed by Engineer-in-charge. 14 M&L for preparation of old surface and treating with two coats of weather proof exterior emulsion paint (Apex ultima or equivalent) over a coat of primer over 3mm thick wall care putty complete all as specified and directed by Engineer-in-charge. 15 Providing and Applying rising damp proof coating system with single component ready to use damp proof coating Roff Hydamp1. Preparation :- Throughly brush and clean all laitance, loose particles such as dirt, grease, mortar droppings, release agents, efflorescence, bird droppings, etc all large voids and hallow portions must be removed and re-plastered non moving cracks having width upto 5mm must be filled with polymer based crack filler.2. Application :- Apply the first coat of Dr. fixit dampguard classic with a paint brush directly on the prepared surfaces by mixing (1 part base : 1 part hardner : 1 part of water), allow to dry for a minimum 2-3 hrs. apply one part of Dampguard mixed chemical and 2 parts of OPC white cement / Birla putty and make the putty, apply putty on the entire surface area, allow to dry for at least 3-4 hrs, apply the final coat of air cure 48 hrs proceeds for paints. 16 Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc. complete all as specified and directed by Engineer-in-Charge. 17 Dismantling floor,hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified & directed. 18 Dismantling Stone slabs and tiles of any description or thickness in floors, aprons etc and laided, bedded and pointed in any mortar complete all as specified and directed. 19 M&L for joint free non skid ceramic coloured tiles 7 to 8 mm thick (square/ rectengular) area of each tile exc 0.18 Sqm but not exc 0.38 Sqm in floor over and including 15 mm thick screed bedding in cement mortar 1:6, set and jointed in neat cement slurry and pointed in coloured cement to match the floorall as specified and directed. 20 M&L for joint free non skid ceramic coloured tiles 7 to 8 mm thick (square/ rectengular) area of each tile exc 0.18 Sqm but not exc 0.38 Sqm as in dado/skirtingover and including 10 mm thick rendering on vertical surface in cement mortar 1:4, set and jointed in neat cement slurry and pointed in coloured cement to match all as specified and directed. 21 M&L for joint free non skid ceramic coloured tiles 7 to 8 mm thick (square/ rectengular) area of each tile exc 0.11 Sqm but not exc 0.18 Sqm in floor over and including 15 mm thick screed bedding in cement mortar 1:6, set and jointed in neat cement slurry and pointed in coloured cement to match the floorall as specified and directed. 22 M&L for glazed ceramic coloured tiles of size 450 x 350 x 7 mm thick on vertical surfaces such as skirting / dados over and including 10 mm thick backing coat in cement mortar 1:4, set and jointed in neat cement slurry and pointed in coloured cement to match the floor complete all as specified and directed by Engneer -in-Charge 23 M&L for 20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite overand including 20 mm thick screed bed in CM 1:6 completeall as specified and directed. 24 Rounding offedges of stone slabs one edge, such as in steps, cooking platform, and other similar situations all as specified and directed 25 M&L for machine cut kota stone slab flooring 20-25 mm thick over cement screed base laid over cement screed base laid over and including15 mm thick screed bed incement mortar 1:6, set and jointed with grey cement slurry mixed with pigment to match shade of the slab including rubbing and polishing complete all as directed. 26 M&L for machine cut kota stone slab 20-25 mm thick in riser of steps, skirting, dado and pillar laid over and including 10 mm thick backing coat in cement mortar 1:4 set and jointed in neat cement slurry mixed with pigment to match shade of the slab including rubbing and polishing complete all as directed. 27 Formwork to chajjas, troughs and similar items including edges , for rough surface of concrete, complete all as specified and directed by Engineer-in-charge 28 M&L for reinforced cement concrete 1:2:4 type B0 using 12.5mm graded stone aggregrate in Chajjas; complete all as specified and directed by Engr-in-charge.Note : Reinforcement shall be measured and paid seperately. 29 S & F TMT Bars (Fe-500D) 10 mm dia and over, cut to length, bent to shape required, including cranking spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed. 30 S&F for TMT bars 6 to 8 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips all as specified and directed. 31 M&L for 75 mm thick PCC 1:3:6 type C-2 using 40 mm graded mechanically crushed stone aggregate as in plinth protection finished even and smooth without using extra cement with & including 10 mm wide, 30 mm deep joints at the rate of 3.00 mtr centre to centre and at every turning & filling the joints with bitumen & sand mixture complete all as directed. 32 M&L for continous brick edging; with burnt bricks old size bricks, with width equal to the width of the brick; liad dry on end verticallycomplete all as specified and directed by Engr-in-Charge. 33 Material and labour for creating fillet caving 50 x 50 mm with ploymer modified mortar on the junction of slab and wall as per manufacture insructions, M & L providing for applying two coats of two components (1 Part Liquid : 2 Part powder) ready to use cemetitious waterproof cating on properly perepared surface by brush having elongation of >50% for the applying water proofing treatment as per following and complete all as directed by the Engineer-in-charge. (i)Applying 1st coat of two components modified polymer coating on horizontal and vertical surfaces.(ii)Applying of glasses fiber mess of 2x2 mm immediately on alone coating. (iii) Applying 2nd coat of two components modified polymer coating after 72 hrs on horizontal and vertical surfaces. Note :Complete treatment to be carried out by authorized applicator of water proofing manufactures Make : Dr fixit/Forsroc/BASF/STP 34 M&Lfor PCC (1:5:10) type E-2 using 40mm graded stone aggregate as filling of sunken floors/bottom and side of drain complete all as specified & directed by Engr-in-charge. 35 Dismantling of Brick tiles in floor or roof laid dry and pointed in cement mortercomplete all as specified and as directed by engineer-in-Charge. 36 Demolition mud in roofs, any thickness, including plastering and leeping and including rubbish off the premises complete all as specified and directed. 37 M & L for 40 mm thick cement concrete 1:2:4 type B-0, using 12.5mm graded stone aggregate as in roof Padding etc and slope 1:40 complete all as specified and directed by Engineer-in-Charge. 38 M&L for Roof treatment to RCC roof as follows:-(a) Cleaning the roof surfaces thoroughly using wire brusehes to remove sharp projections, cleaning joints, washing, drying and removing all dirt/dust to receive concrete padding/plaster etc. (b) Providing 15 mm thick screed bed or bedding layer of cement mortar (1:4) with WPC, finished even and smooth without using extra cement. (c) Providing one coat of approved bituminous primer @100 gms per sqm, over dried plastered surface. (d) Laying 3 mm thick APP membrane,(mineral finish) reinforced with non woven polyster fabric, by torch application. The overlapping while torching shall be 75 mm on longitudinal direction and 100 mm on the transverse direction complete all as specified and directed by E-in-Charge.Notes : (i) All joints and change in directions should be covered wih cement mortar (1:3) mixed with SBR latex @ 200 ml/bag of cement/as per site reqmt and cured well before laying membrane by torching.(ii) All angles and abuttments should be sealed well with extra care to ensure full bondage. (iii) Water proofing treatment shall be got carried out by approved authorised applicator of manufacturer only. The name of firm shall be got approved from GE before carrying out the wk. (iv) The independent testing of membrane for technical parameters given in particular specifications shall be carried out from Govt approved labs having fascilities for testing of membrane. (v) The guarnatee of treatment shall be for min 10 yrs reckoned from date of completion of whole wk. 39 M&L PCC 1:2:4 type B-1, using 20mm graded stone aggregate as in roof kerbs or mud stops, and like rounded or chamfered on edges including necessary form work etc complete all as specified and directed by Engr-in-Charge. 40 Material and labour for repair to damage RCC coloumns/Beam/Slab/Chajja by using micro mortar and concrete in Following Stages :-(a)Removing the mortar and loose concrete from RCC elements.(b)Cleaning the rusted reinforcements and applying rust removal.(c)Inserting the addl reinforcements in case the coves sectional area reduction is more than 20 percent by welding the reinforcement with existing bars and supporting adequate on walls if reqiurd with grout.(d)Providing micro mortar and concrete over bond coat to cover the reinforcements and steel surface.(e)Providing adequate formwork and scaffolding if required.(f) Curing the surface.Note :- (i)Rust removal, bonding agent, grout, micro mortar and concrete and related chemicals shall be of Dr Fixit/BASF and STP(ii) Work is to be got executed from authorised applicator of the company.(iii)Steel reinforment shall be measured and paid separately 41 Taking down chowkhats or frames n.exc 1.5 sq. meach with shutters (without taking off shutters from the frame) complete all specified and directed directed. 42 Taking down chowkhats or frames exc 1.5 sq. m but n.exc 4.0 sq. m each with shutters (without taking off shutters from the frame) complete all specified and directed directed. 43 Taking down existing shutter and refixing in same opening shutters of any description exc 1.0 Sqm but not exc 2.0 Sqm each all as specified and directed.(Note:- Refixing includes taking down, easing and adjusting and also refixing builders hardware as required including renewal of unserviceable screws, etc.) 44 Supply and fixing of Fibre glass Reinforced plastic (FRP)door frame of required colour of cross-section 90mm x 45mm having single ribate of 32mm x 15mm to recieve shutter of 30mm thick includinglaminated door frame moulded with fire retardant grade unsaturated polyster resin and chopped strand mat(CSM) also door frame laminated shall be 2mm thick and shall be filled with suitable wooden block of 2nd class hard wood, frame shall be covered with fibre glass from all sides. MS stay flat iron 25mm x 3mm shall be provided at the bottom to steady the frame complete all as specifiedand as directed by Engineer-in- charge. 45 Supply and fixing of 30 mm thick glass fibre reinforced plastic (FRP) paneled door shutter conferming to IS:14856-2000 of required colour andmade with fire retardant grade unsaturated polyster resin,moulded to 3mm thick FRP laminated for forming hollow rails and style with suitable second class hardwood timber block inside at required places for fixing of fittings,cast molithically with 5mm thick FRP laminated for panels including fixing to frames,complete all as specified and as directed by Engineer-in- charge. 46 M & L for rolled mild steel in framed work as in doors or gates of angle or other section with gusset plates, rails, braces etc complete drilled for fixing of steel sheeting of other covering, doors etc to be prepared for hanging or sliding with and including either hooks and hinges or steel handing door fitttings (exclusive or steel sheeting or other covering, running rails and guides) and hanging also fastening and fixing confirming to Fe-290 (Gde-165) complete all as specified and directed by Engr-in-charge. 47 S & F for Pressed steel frames 125 x 60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete all as specified and as directed by Engineer-in- charge. 48 S&F for 35 mm thick 2nd class hard wood factory made plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and directed. 49 S&F for 35 mm thick 2nd class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a) complete all as specified and directed. 50 S&F for 100 mm long butt hinges with stainless steel hings pin, anosied and fixedcomplete all specified and directed. 51 S&F aluminium anodised barrel tower bolt of extruded section 200mm longall as specified & directed by Engr-in-charge. 52 S&F in repair 150 mm long extruded aluminium alloy handle, fabricated type anodised complete all as specified and directed. 53 S&F 100 mm mild steel pressed handles, oval type, stove enamelled blackcomplete all as specified and directed by Engneer -in-Charge . 54 S & F 150 mm mild steel barrel bolts, stove enammelled black eith bright bolt and fixed complee all as specified and directed 55 S&F 100 mm long butt hinge, medium weight, cold rolled mild steel complete all as specified and directed by Engneer -in-Charge . 56 S&F for 300 mm long mild steelsliding door bolt type, stove enamelled black, with bright bolt not less than 12 mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate complete all as specified and directed. 57 S&F 300mm ordinary rat tail rod pattern springs including roller and roller platecomplete mild steel fixed complete all as specified and directed. 58 S & F stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed by Engr-in-Charge. 59 S & F 4.00 mm thick sheet glass, ordinary quality and glazing with aluminium snap beading of any size of glass in each pane allas specified and directed. 60 S&F for 150 mm long floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring all as directed. 61 M&L for preparation of new or previously untreated wooden surface of any description not otherwise described over 10 cm width or girth and apply two coats of synthetic enamel paint over one coat of pink primer all as specified. 62 M&L for preparation of old wooden surface of any description not otherwise described over 10 cm width or girth and apply one coats of synthetic enamel paintall as specified. 63 S&F for powder coated aluminium frame for doors, windows, ventilators and aluminium partition with one or more rebates including jointing cleats glazing clips, rubber packing, anodised aluminium snap beading, screws etc complete with locking arrangements for fixing with powder coating on aluminium sections, minimum thickness of powder coating shall be 50 micron as per the specification. The top and bottom horizontal members and vertical members adjacent to wall shall be fixed with floor, ceiling, walls and cills where required and fixed with the help of rawl plugs and screws or with fixing clips or with expansion hold plate fastners. Aluminium section shall be smooth, rust free, straight, mitred and jointed mechanically whereever required complete in all respect all as specified & directed by Engr-in-Charge. 64 S&F for powder coated anodised aluminium window and ventilator shutters,, aluminium sections weighing exc 0.55 Kg/m including necessarynecessary joining cleats, glazing clips, rubber neoprene packing, handles 1 Nos in each door, hinges (03 Nos),anodised aluminium snap beading, screws,complete all as specified 65 S & F for Aluminium anodised (Powder coated) Three track sliding window frame with shutters (two glazed and one gauged shutter)including all necessary joining cleats, hold fast, rubber gasket, snap beading and locking arrangements fixed with screws to wall etc. complete andglazing with 5 mm thick tinted glass to aluminium frame work using rubber gasket and including stainless steel wire cloth of 0.36mm dia & average width of aperture 1.40mm with staple or suitable fillets wire mesh fitted with screws and washers etc with the following section of frame and shutter(A)Sections for frame (i) Top and verticals 92 x 29.50 x 1.30 mm thick (ii) Bottom 92 x 29.50 x 1.20 mm thick. (B) Sections for shutter (i) A section 39 x 20 x 1.50 mm thick (ii) Interlock section 39 x 20 x 1.50 mm thick(iii) H section 41 x 20 x 1.10 mm thick 66 S & F 4 mm thickfigured glass, pin head secured with oil putty in squares n exc 0.5 sq. m in each pane complete all as specified and directed. 67 Material & Labour for mild steel work conforming to Fe-290 (E-165) as in grills, gratings etc. with ends of bars shouldered and/ or rivetted or forged into spikes; framed guard bars, walkways, railing, framed work of water tanks and similar works complete all as directed by Engineer-in- charge 68 M&L Cement concrete 1:3:6 type C-1 using 20 mm graded crushed stone aggregate for foundations, fillings and mass concrete complete all as specified and directed by Engineer-in - Charge. 69 M & L for painting steel and iron surfaces of any discription,over 10 cm width or girth, with preparation of new or previously untreated surfaces priming with one coat of read oxide & finish with two coats of synthetic enamel paint ordinary tint all as spefified and directed by Engr-in-Charge. 70 S&F in repair drapery stainless steel rods, standrad quality, not less than 25mm dia with brackets and heads at both ends, etc. complete all as specified and directed by Engr-in-charge. 71 S & F in repair sheet glass shelf assembly consisting of 5.5 mm thick sheet glass shelf 12 mm with chromium plated bracket guard and railing 60 cm long all as specified and directed 72 S & F in repair aluminium hat peg, solid body 125 mm to 175 mm (4 Legs) complete all as specified and as directed by Engineer-in-charge. 73 S&F in repair towel rails 20mm dia 600mm long brass chromium platedcomplete all as specified and directed by Engineer-in-Charge. 74 S&F in repair chromium plated fancy type soap dish 10cm/15cm complete all as specified and directed by Engineer-in-Charge 75 S&F in repair vitreous china squatting pan Orissa pattern size 580 x 440 mm white with integral foot restsbut including CI P trap set in and including concrete fixed complete all as specified and directed by Engineer-in-Charge. 76 S&F in repairs PVC valve less, syphonic action type flushing cistern,10 ltrs capacitylow level, white, with inlet ball valve, float, handle and telescopic pipe flush pipe of polyethylene of low or high density or PVC, 32mm dia, for low level cistern and connection to pipes all as directed. 77 S&F in repair vitreous china wash hand basin coloured Flat back of size 550x400mm,including 32mm dia chromium plated waste coupling long screwed shank andfly nut, flanged end bedded in red led cement and other end fixed and PVC waste pipe including cutting for and pinning in ends of brackets in CM 1:3 all as specified . 78 S&F in repair pillar tap, fancy type, cast copper alloy chromium plated with capston head, screwed down high pressure with or without lettered with long screwed shank and fly nuts, screwed for iron pipe of 15 mm bore complete all as specified and directed. Note: Wt not less than 450 gms 79 S&Fbib tap 15mm bore cast copper alloy chromium plated long body fancy type with capston head and cup screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed by Engineer-in-Charge. 80 S&F in repair CP brass stop/angle valvefancy type 15 mm bore cast copper alloy screwed down high pressure fancy type with long shank and cup fixed complete all as specified and directed by Engineer-in-Charge. 81 S&F in repair CP brass stop valve/ angle valve fancy type 15 mm bore cast copper alloy screwed down high pressure fancy type with long shank and cup (Concealed type) fixed complete all as specified and directed by Engr-in-charge. 82 Supply & fixing in repairs CP swivel shower roses 125mm with or without swivel joints, including fixing to steel pipe or union fixed complete all as specified and directed by Engr-in-Charge. 83 Supply & fixing in repair450 mm long PVC connection 15mm size with PTMT nuts complete all as specified & directed by Engineer-in-charge. 84 S&F in repair looking mirror of selected quality of size600 mm X 450 mm withbevelled edge mounted 6 mm thick commercial plywood and aluminium channel of required size fixed to wooden plugs with chromium plated brass screws and cup washers all as directed. 85 Dismantling of water tanks of capacity exc 250 and n.exc 500 ltrs and removing from site all as specified and directed. 86 S&F for Rotational moulded polythene water storage tank 500ltr capacity vertical with closed top, ISI marked hoisted and fixed in position all as specified in SSR part-I. connection nipple 2 Nos complete all as specified and directed.. 87 S&F in repair gun metal globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed of 20mm bore complete all as specified and directed 88 S&F in repair ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed in 20mm dia bore pipe complete all as specified and directed by Engr-in-charge. 89 Taking down 15 mm dia steel GI tubing including all connectious fittings in any position including cleaning for re fixing the serviceable pipe all as directed. 90 Taking down 20 mm dia steel GI tubing including all connectious fittings in any position including cleaning for re fixing the serviceable pipe all as directed. 91 S&F 15 mm diagalvanised steel tubing medium grade including necessary fittings like sockets, tees, elbows, reducers, unions etcfixed to walls / ceilingcomplete all as specified and directed by Engineer-in-Charge. 92 All as per Srl item no 91 above butexecpt pipe only complete all as specified. 93 S&F 20 mm diagalvanised steel tubing medium grade including necessary fittings like sockets, tees, elbows, reducers, unions etcfixed to walls / ceilingcomplete all as specified and directed by Engineer-in-Charge. 94 All as per Srl item no 93 above butexecpt pipe complete all as specified. 95 Taking down eaves gutters and rainwater pipes/PVC SWR (any size or pattern) including all fittings, heads, shoes, bends, swan-necks etc.,complete all as specified and directed by Engineer-in-Charge. (measured overalll as fixed along the centre line over fittings and accessories) 96 S&F 110 mm dia PVC SWR pipe, single socketed in any length with rubber ring joints fixed with clamps to walls complete all as specified and directed by Engineer-in-Charge. 97 S&F in repairs 32 mm dia low density polyethylene pipes (LDPE) of pressure rating 6 kgf/cm2 fixed complete to walls, ceilings or in floors complete all as specified and directed by Engineer-in-Charge. 98 S & F stainless steel kitchen plate rackmade out with 1 mm thick sheet of size 24x24x 10 including taking down existing wooden plate rack complete all as specified and directed by Engineer-in-Charge 99 S&F in repair kitchen sinks made of stainless steel 1mm thickwith plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to waste pipe, overall size 485mm x 420mm bowl size 410mm x 330mm x 160mm complete all as specified and directed by Engineer-in-Charge. 100 S & F in repair 100 bore of spun cast iron soil, waste and vent pipes in any length with or without ears, with cement joint and laid in trenches or in floors cast ironcomplete all as specified and directed by Engineer-in-Charge. 101 S & F in repair cast iron 100 mm bore branch pieces, single (equal or unequal),ordinary or inverted (spigot or socket type) or with parallel branches complete all as specified and directed by Engineer-in-Charge. 102 S & F in repair cast iron 100 mm bore Bends (any radius), diminishing pieces or tapers (larger bore measured) complete all as specified and directed by Engineer-in-Charge. 103 S & F in repair 75 bore of spun cast iron soil, waste and vent pipes in any length with or without ears, with cement joint and laid in trenches or in floors cast ironcomplete all as specified and directed by Engineer-in-Charge. 104 M & L in repairs 75mm cast iron floor trap, with grating including jointing to waste pipe fixed in cement concrete type B-1, (1:2:4) complete all as specified and directed by Engineer-in-Charge. 105 S & F cast iron 75 mm bore branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branchescomplete all as specified and directed by Engineer-in-Charge. 106 S & F in repair cast iron 75 mm bore Bends (any radius), diminishing pieces or tapers (larger bore measured) complete all as specified and directed by Engineer-in-Charge. 107 M&L for 100mm thick PCC (1:4:8) type D2 using 40mm graded stone aggregate as in sub base below floors all specified and directed. 108 M&L Machine pressed precast concrete interlocking paver block glossy with grey cementand pigment, any shape and size confirming to IS 15658-2006 of 60mm thickness M-35 gradeover Fazilkasand cushion and incl dismantling all as specified and directed. 109 Supply only fine aggregate (sand) for cushioning (Fazilka Sand) all as specified and directed 110 M&L for PCC 1:2:4 type B2 using40mm graded aggregates as in benching / haunching ofmanholes including forming channels including necessary formwork etc complete all as specified and directed by Engr-in-charge. 111 M & L for plain cement concrete 1:2:4 type B-1, using 20 mm graded crushed stone aggregate as in coping & bed block etc including weathering, slightly, rounded or chamfered angles and throating as directed necessary form work complete all as specified and directed. 112 M&L precast cement concrete 1:2:4 type B1 using 20mm graded stone aggregate and set cement mortar 1:6 as in cover slabs (for manholes etc,) chajjas, shelves and similar articles with plain faces complete all as specified and directed by Engr-in-charge. 113 M & L for cement concrete tiles 25cm x 25cm x 22mm thick, m a c h i n e pressed with grey cement and pigment over cement screed base laid over and including15 mm thick screed bed incement mortar 1:4, set and jointed with grey cement slurry mixed with pigment and no pigmentin floors/roof, and cut and polished complete all as specified and directed. 114 M & L for preparation of newly primed surface of steel over 2 coats of synthetic enamel paint over 10 cm width or girth not specified otherwise complete all as specified and directed. 115 M&L for old size brick work with sub class B bricks straight or curved any radius half brick thick walls, built in cement mortar (1:4) all as specified & directed. 116 M & L for 19 mm thick plywood, grade BWR, type BB, fixed with screws to timber frame work complete all as specified and directed 117 Demolition of breaking up drain pipes of internal dia 150 mm (Salt glazed ware, AC or Reinforced concrete) set in cement mortar or cement concrete complete all as specified and directed.Note : Earth work shall be measured and paid seperately 118 Supply and laying DWCPE (SN8) 180 (OD)/150 (ID) mm dieameter drain pipes as per IS-16098 (Part-II), Laid in trenches on moorum bed to required slope, including all accessories/fittings, jointing and tested complete all as specified and as directed by Engineer-in-Charge 119 M & L Cutting into existing manholes for connecting new drains, making good to pipe and rendering cutting out existing benching for and forming branche channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 20mm graded crushed stone aggregate smooth finished and forming benching as required, Internal dia of pipe 150 mm complete all as specified. 120 M&L PCC 1:4:8 type D2 using 40mm graded aggregate as in foundation, filling & mass concrete complete all as specified and directed. 121 Material and labour for brick work with Fly Ash bricks straight or curved on plan exc. 6 metre mean radius built in cement mortar (1:4) complete all as specified and as directed by Engineer-in-charge. 122 Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed 123 E/M PortionTaking down carefully existing aluminium/copper point wiringfor light, fan, socket or power bell complete with fittings such as Switches, sockets, ceiling roses, holders, call bells & making good the disturbed surfaces of walls, matching the colour with existing surface complete all as specified and directed.Note : Rate for making good shall be deemed to be included in above item rate. 124 Taking down MCB with sheet metal enclosure, main switch, DB, etc and making good disturbed surfaces to match with existing surfaces. 125 Taking down carefully submain wiring/ service connection of any type complete with casing caping / conduit etc complete all as specified and directed. 126 M&L for concealed Point wiringfor One light, one way switchcontrolled by one, oneway switch with single core PVC insulate, unsheathed multistranded copper conductorcable of size 1.5 sq.mm (FRLS) drawn in and including electrical grade PVC conduit20 mm dia concealed on wall/ceiling/floorincluding PVC insulated unsheathed earth wire with multi stranded copper conductor of size 1.5 sq.mm(FRLS) including MS shunk sheet metal box with 3 mm thick bakelite plastic laminated sheet top cover with brass counter shunk screws with washercomplete all as specified. Note - quoted rate shall include making good to the disturbed surfaces including plastering andpaintingto match with the existing colour. 127 All as per srl item No 126 above, but for ceilling/exhaust fan point controlled by one switch and regulator complete all as specified and as directed. 128 All as per srl item No 126 above, but for3 pin 5 Amp socket outlet on the same board with other switch, sockets complete all as specified and as directed. 129 All as per srl item No 126 above, but for one 3 pin 5 Amp socket outlet on independent board complete all asspecified & directed 130 All as per srl item No 126 above, but for One bell/buzzer point controlled by one bell push 131 All as per srl item No 126 above, but for Two way point controlled by two way switch 132 All as per srl item No 126 above, but wiring with 4 Sqmm multistranded cable and earth wire with copper conductor of size 4 Sq mm for 15 amps all as specified 133 Supply and fix piano type, 230/250 Volts grade on top covers (catered in pint wiring above), Modular switch 1 way 6 A, 1 module complete all as specified and as directed. 134 All as per srl item No 133 above, but for Modular switch, two way 6 Amp, 1 Module complete all as specified and as directed. 135 All as per srl item No 133 above, but for Modular switch, one way 16 Amp, 1 Module complete all as specified and as directed. 136 All as per srl item No 133 above, but for Modular bell push 6 Amp, 1 Module complete all as specified and as directed. 137 Supply and fix modular Socket outlet 2 in 1, 3 pin multipurpose type 5 Amp, flush type (2 module) (Catered in point wiring above) complete all as specified and as directed by Engineer-in-charge. 138 Supply and fix modular Socket outlet 2 in 1, 3 pin multipurpose type 15 Amp, flush type (Catered in point wiring above) complete all as specified and as directed by Engineer-in-charge. 139 Supply & fix batton integrated LED light fitting 1 x20 integral sleek polycarbonate LED channel with white acrylic cover to roof/ceiling/wall with necessary wooden/PVCblocks etc and connecting with 2 core flexible PVC insulated multistranded copper conductor from ceiling rose to fitting complete all as specified and directed including taking down old one. Note : (i) with lumen efficiency in excess of 100 Lumans per watt and driver effeciency >85% (withpf>0.95) (ii) CRI >80 140 Supply and fix in repair Lamp holder, PVC/Polycarbonate type complete with lamp LED 9 Watt for angle/Batten fitting with back plate and all fittings complete all as specified and directed by Engr-In-Charge 141 Supply and fix LED bulk head lightfitting, 1 x 10 Watt in die cast aluminium housing & frosted glass complete all as specified and directed by Engr-In-Charge 142 S & F LED mirror light fitting, 01 x 10 Watt durable & weather proof industrial lighting solution luminaire with IP-65 protection acomplete all as specified and directed 143 Supply and fix ceiling rose surface bakelite two to three terminals/plate 5 amps complete all as specified and directed by Engr-in-Charge. 144 Supply and fix sheet metal enclosure DB single pole and neutral for 240 volts 8 way with 200 Amps rated busbarflush/surface mounting double door complete all as specified and directed 145 Supply and fix in repair V TPN DB 4 way suitable for 100 Amps including MCCB 4 pole 125 Amp 16 KAcomplete with 200 Amps rated busbarflush mounting, double door, proction class IP-30, IK08 complete all as specified and directed 146 Supply and fix MCB single pole 240 Volt 6-32 Amps 10 KAcomplete all as specified and directed 147 Supply and fix MCB240 Volt 63 Amps 10 KAcomplete all as specified and directed 148 Supply and fix MCB TP & N 63 Amps, 10 KA complete all as specified and directed 149 Material & Labour for Sub Main Wiring with two run single core 10 Sqmm PVC insulated unsheathed(FRLS) cable with stranded copper conductor drawn in PVC conduit & accessories Suitable size with and including 10 Sqmm copper green colour earth wire all as specified and directed by Engineer-in-Charge.NOTE-two run of 10 sq.mm & One run of 10 sq.mm & One run ofPVC conduit with accessories shall be measured as One length complete all as specified and directed. 150 M&L for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth of not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick and packed layer of charcoal dust and common salt, connected to earth lead ofGI wire 4 mm dia (8 SWG) by means of bolts, nuts and washers of the earth wire.galvanised iron or steel and thimbles and other end of the earth wire connected to earthing test point and protected by galvanised iron pipe light grade 15mm dia and water pipe 20mm dia GI light grade with funnel and wire mesh, PCC chamber in cement concrete (1:2:4) type B-1and CI cover with frame all as shown in electrical plate No. 3 of MES Schedule Part-I of SSR-2009. Notes :- (i) 20 mm dia GI pipe for watering to be provided with a socket and plug and should be 10 cms above ground level. (ii) Outer edge of earth pit will be 1 metre away from the outer edge of PCC chamber. (ii) GI wire upto DBs earth connection is included in this item.(iii) Water pipe shall be provided in slanting position 151 Supply and fixing single pole and neutral sheet metal enclosure with a two pin and earth plug and socket complete with one single pole MCB of capacity 20 Amps, 240 volts, AC supply complete all as specified and directed by Engineer-in-Charge. 152 Supply and fixing in repair LED light fitting as building security lights of 45 Watt Cap 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, with epoxy powder coated CRCA sheet steel grey tray, clear acrylic cover,incl street light bracket made out of 25 mm dia GI medium grade pipe 0.6 mtr long complete with 2 sets of FI clamps made out of 30x5 MS flat & nuts, bolts & washer including painting to clamp with two coats of aluminium silver paint over a coat of primer, with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed by Engr-In-Charge 153 Supply and fix single phase electronic meter tamper proof LCD Display with poly carbonate cover 230 V,10-60 Amp accuracyclass -I 50 Hz, conforming to IS 13779, IP-54 with parameters to show data, time, current reading , load, PF, Voltage and KWH complete all as specified and as directed by Engr-In-Charge.Note : old U/S meter will be deposited in MES store 154 S & F modular fan regulator, 120W-2Module complete all as specified and directed by Engr in charge. 155 Supply and fix in repair Fresh air fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250 MM complete all as specified and directed by Engr-In-Charge. Old U/S Fresh air Fan will be deposited to MES Store yard by the contractor and no schedule of credit will be given tothe contractor on account of this item all as specified and directed by Engr-in-Charge. 156 Supply and fix in replacement electric water heater, storage type steel body with stainless steel inner tank and heating element upto 2 KW capacity 25 litre, ISI marked, energy efficient complete with all accessories such as safety valve, thermostate NRV, connection piece etc.including taking down old geyser complete all as specified and directed.Note : Old geyser shall be deposited to MES store yard without any extra cost of transportation 157 Supply and hanging /fixing in repair ceiling fan 1200 mm sweep AC Supply (Input Voltage Range ; 120 to280V), BLDC type, 5 star rated, BEE and ISI Marked super enamelled, copper winding of B class insulation, single phase, maximum 30W (± 10%), Temperature rise 40 degree maximum without remote with and including capacitive regulator, 03 No blades, down rod including accessories, white colour, total harmonic less than 10%, 5 speed, hanging in position including making connection with flexible cord three core twisted copper conductor of suitable sizefrom ceiling rose to fan complete all as specified.Note :- (i) Serial Number as issued by Engr-In-Charge of celing fan and GE Office name shall also be written on fan with red colour permanent marker and fixing of regulator on switch board, cost for the same shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account(ii) Old U/s Fan shall be deposited to MES store yard without any extra cost of transportation 158 Supply and fix in repair heavy duty exhaust fan, steel body AC single Phase. 230V of size 300 mm sweep with, blades and fan motor of Cap at least 190 Watt or above , and frame and louvers Complete all as specified and directed by Engr-In-Charge. Old U/S exhaust Fan will be deposited to MES Store yard by the contractor and no schedule of credit will be given tothe contractor on account of this item all as specified and directed by Engr-in-Charge.. 159 Supply and fixingelectric calling Bell Ding Dong type, AC 230 Volts single pole including making elctric connection complete all as specified and as directed by Engr-in-charge. 160 Supply and laying and testing cable LT XLPE insulated, screened, PVC bedded, glavanized steel strip or wire armoured, electric power cable (heavy duty) 1100 volt grade with stranded aluminium condutor size 16 Sqmm 4Core including making necessary electrical connections by using AI thimbles of appiropriated size complete all as specified and directed Note : Excavation, earthwork will be measured and paid separately under respective item respective item of BOQ.. 161 Excavation in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundations, shafts, wells, cesspits, manholes, laying pipe line, laying of cables or fixing poles and stays and struts etc. not exceeding 10 Sqm on plan and not exceeding 1.5 metre in depth and getting out in soft/loose soil complete all as specified and as directed by Engineer-in-charge. 162 Returning filling in incl spreading, levelling watering and well ramming in layer n.exc 25cm thick complete all as specified and directed. 163 Removing surplus soil to a distance n. exc 50 m and depositing where directed at level n. exc 1.5 m above the starting point complete all as specified and directed by Engr-in-Charge 164 M&L sand cushioning with dry and clean locally available sand for under ground cable 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of cable complete all as specified.(Note : Punned thickness shall be considered for payment purpose) 165 Supply and laying well brunt clay brick old size class B laid dry flat for protection over the cable, width equal to length of cable complete all as specified and directed. 166 Note:- The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender, from total amount of Schedule A/BOQ

Key Value

Document Fees
INR 500 /-
EMD
INR 53000.0 /-
Tender Value
INR 26.50 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Document 0 KB
Click here to download tender document Tender Document 0 KB
Click here to download tender document Tender Document 0 KB
Click here to download tender document Tender Notice 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail