}

Tender For Sitc Of Pump At Nathu Colony-Sitc Of Electrical Pumps Along With E&M Allied Works For Storm Water Pump House At Nathu Colony Under Ee(E&M)-Ii Snz Mcd, Dsr Dar Electrical-2022, Dar Civil-2018, Dar Electrical (With Cp Only)-2022, Dar Electrical (, Delhi-Delhi

Municipal Corporation Of Delhi has published Tender For Sitc Of Pump At Nathu Colony-Sitc Of Electrical Pumps Along With E&M Allied Works For Storm Water Pump House At Nathu Colony Under Ee(E&M)-Ii Snz Mcd, Dsr Dar Electrical-2022, Dar Civil-2018, Dar Electrical (With Cp Only)-2022, Dar Electrical (. Submission Date for this Tender is 03-10-2024. Construction Material Tenders in Delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

45462158
Tender For Sitc Of Pump At Nathu Colony-Sitc Of Electrical Pumps Along With E&M Allied Works For Storm Water Pump House At Nathu Colony Under Ee(E&M)-Ii Snz Mcd, Dsr Dar Electrical-2022, Dar Civil-2018, Dar Electrical (With Cp Only)-2022, Dar Electrical (
Open Tender
Indian
Delhi
Delhi
03-10-2024

Tender Details

SITC of pump at Nathu colony-SITC of electrical pumps along with E&M allied works for storm water pump house at Nathu colony under EE(E&M)-II SNZ MCD, DSR DAR ELECTRICAL-2022, DAR CIVIL-2018, DAR ELECTRICAL (WITH CP ONLY)-2022, DAR ELECTRICAL (WITH CP ONLY)-2022 and approved items; 1 DSR Electricals 2 18.7.8:Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :150 mm dia 3 3.2.6:Supplying, installing, testing and commissioning of following capacity TPN tap off box made of1.6mm thick sheet steel enclosure duly painted with powder coating on existing rising mainscomplete with TPN disconnector FSU and HRC fuses, connections, earthing etc. as required.315 amps TPN 4 4.1.3:Supplying and installing following size of perforated pre-painted M.S. cable trays withperforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.225 mm width X 50 mm depth X 1.6 mm thickness 5 4.1.1:Supplying and installing following size of perforated pre-painted M.S. cable trays withperforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.100 mm width X 50 mm depth X 1.6 mm thickness 6 4.3.1:Supplying and installing following size of perforated pre-painted M.S. cable trays reducers withperforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.100 mm width X 50 mm depth X 1.6 mm thickness 7 4.3.3:Supplying and installing following size of perforated pre-painted M.S. cable trays reducers withperforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.200 mm width X 50 mm depth X 1.6 mm thickness 8 9.1.23:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 70 sq. mm (38mm) 9 9.1.24:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 95 sq. mm (45mm) 10 5.3:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) as required. 11 5.9:Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) 12 1.1.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C 13 1.7.2:Wiring for circuit/ sub main wiring alongwith earth wirewith the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required2X2.5 sq.mm+1X2.5 sq.mm earth wire 14 1.7.3:Wiring for circuit/ sub main wiring alongwith earth wirewith the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required2x4 sq.mm + 1x4 sq.mm earth wire 15 1.22.3:Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required.150 mm X 75 mm X 60 mm deep 16 1.22.5:Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required.180 mm X 100 mm X 60 mm deep 17 2.3.2:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator8 way, Double door 18 2.10.1:Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole 19 2.10.3:Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole 20 19.1:Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 21 1.50.1:Installation of exhaust fan in the existing opening, including making good the damage connection testing, commissioning etc. as required.Upto 450 mm sweep 22 7.7.1:Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KVgrade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle) 23 7.7.2:Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KVgrade of following size on wall surface as required.Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) 24 DSR Civil 25 4.1.4:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (1 Cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 40 mm nominal size derived from natural sources) 26 Approved rates electrical 27 122.1.3:Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-2C*10 sqmm 28 122.1.19:Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-3.5C*70 sqmm 29 122.1.20:Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-3.5C*95 sqmm 30 122.1.47:Supply of 250 mm (10 inch) sweep 1250 rpm exhaust fan Fresh Air Type complete with shutter blades etc. as required. 31 122.2.2: P/FHot press sheet mouldedcompound (SMC) fire retardant (Temp. resistance up to 200 C), IP 55 weather proof polebox of innerdimension 200x160x98mm (NS) complete with suitable arrangement for fixing of 2 nosof 6 to 32 amp single pole MCB & 63 Amp. Doublepole isolator (MCB/Isolator excluded) withneutral link duly shorting on DIN Channel with2 Nos of MS clamps with SS back plateofsuitable size with danger monogram property printed on the coveretc asreqd. asreqd. 32 122.2.4:SITCof Pillar box size 900 mm x 450mm x 250mm suitable for mounting incomer of 250 A MCCB/Main switch 4 Pole and energy meter 3 phase complete with eluotropic grade Aluminium bus bar of size 25mm x 19 mm mounted on galvanized M. S. body power quoted pilferage proof SMC door duly welded with S.S. withrain cover size 40mm x 40mm x 5mm x 600mm height in cutting 300 mm height below groundand covered with shode proof SMC sheet of 3 mm as required. 33 122.2.29:SITC of 100W LED Flood Light luminiare fitted with lens, made of pressure die cast aluminium housing & toughened glass cover complete with the following specification as reqd with IP 66 protection (a) Total system wattage =100 watt +/- 5% (b) Luminaire Efficacy>=100 Lm/w (c) Power Factor>=0.95 (d) Protection Class- IP-66 34 122.2.39:S/I/T/C of LED Tube type luminaire 20 Watt rating complete with polycarbonate housing batten integrated electronic driver prewired with high efficient LEDs with the following:(a) Total system wattage 20 watt +/- 5%(b )Luminous efficacy lumens/watt >=95 (c)Power Factor >=0.95 35 OD30305/2023-2024:Supply of 16 sq mm ISI marked FRLS PVC insulated, single core copper conductor cable 36 Approved rates E&M 37 OD30306/2023-2024:Supply installation testing and commissioning ofElectrical Horizontal centrifugal pump set with non-clog / mf impeller to handle storm/mixed/sewage water with having min. discharge of 800 M³/ Hour at head min 7 mtr, RPM 750 having suction and delivery size 350 mm or 300 mm dia, mounted on a common base frame coupled with min 40 HP or suitable rating(IE-2) three phase , TEFC AC , 415 volts , 50 HZ supply electrical motor energy efficient complete as required.Mounted on a common base frame as Casing CI , Impeller CI,Shaft & sleeve (SS) 40 C 8 complete with coupling guard and foundation bolts etc. as reqd. 38 OD30307/2023-2024:P & F/Replacement of M.S Black pipe(9.5 mm thickness) Conforming to IS:3589 withrequired nut bolts and packing sheet etc complete as reqd of following dia 400 mm ,9.5 mm thickness 39 OD30308/2023-2024:P & F/Replacement of M.S Black pipe(9.5 mm thickness) Conforming to IS:3589 withrequired nut bolts and packing sheet etc complete as reqd of following dia 350 mm ,9.5 mm thickness 40 OD30309/2023-2024:P & F/Replacement of M.S Black pipe(9.5 mm thickness) Conforming to IS:3589 withrequired nut bolts and packing sheet etc complete as reqd of following dia 300 mm ,9.5 mm thickness 41 OD30310/2023-2024:Providing & Fixing ofM.S Flange with required nut bolts and packing sheet etc complete as required of following dia. 400 mm ( 25 mm thickness) 42 OD30311/2023-2024:Providing & Fixing ofM.S Flange with required nut bolts and packing sheet etc complete as required of following dia. 350 mm ( 25 mm thickness) 43 OD30312/2023-2024:Providing & Fixing ofM.S Flange with required nut bolts and packing sheet etc complete as required of following dia. 300 mm ( 25 mm thickness) 44 OD30313/2023-2024:Providing & Fixing ofM.SBlind Flange with required nut bolts and packing sheet etc complete as required of following dia. 400 mm ( 25 mm thickness) 45 OD30314/2023-2024:Providing & Fixing ofM.S Bend with required nut bolts and packing sheet etc complete as required of following dia. 400 mm(10 mm thick),length 0.75 m 46 OD30315/2023-2024:Providing & Fixing ofM.S Bend with required nut bolts and packing sheet etc complete as required of following dia. 350mm(8 mm thick),length 0.75 m 47 OD30316/2023-2024:Providing & Fixing ofM.S Bend with required nut bolts and packing sheet etc complete as required of following dia. 300 mm(08 mm thick),length 0.75 m 48 OD30317/2023-2024:Replacement of swing type Non Return Valve of CI Body with Door, bronze to Rubber rings confirming to IS 5312(Part 1 & 2), PN 1.6 complete as required NRV 350 MM 49 OD30318/2023-2024:Replacement of swing type Non Return Valve of CI Body with Door, bronze to Rubber rings confirming to IS 5312(Part 1 & 2), PN 1.6 complete as required NRV 150 MM 50 OD30319/2023-2024:Replacement of Non Rising Spindle Sluice Valve of CI Body with Wedge, Bronze ring confirming to IS 14846 & SS IS:6603 (ISI Marked), PN 1.6 complete as required: SV 350 MM 51 OD30320/2023-2024:Rubber Sheet 10 mm thick 52 OD30321/2023-2024:Mounting pad(AVM) 53 OD30323/2023-2024:Providing & Fixing of MS Bar Screen made out of MS channel size 4 x 2 (100 mm x 50 mm) and center covered with MS Flat size 80 x 8 mm duly welded with center to center distance 40 mm and back side supporting channel (100 x 50 mm)duly welded .Work also includes complete bar screen fixing in the drain with the help of heavy crane and complete bar screen duly painted with enamel paint. Bar screen duly fixed in side wall using mortar , tools and tackles. (sq feet) 54 OD30324/2023-2024:S/I/T/C of fully automatic Auto Transformer Starter will be made out / fabricated with 2 mm thick, MS sheet steel ,dust & vermin proof, darn & drip-proof , front operated , self supported, free standing type constructions and will be duly spray painted Sythetic Enamel of light grey shade 631 of IS:5 and accomodate all switch gear items required to meet the technical requirements of ATS 50 HP & Adequate rating Oil immersed Auto Transformer having Copper winding , class E insulation with taping 50%,65%&80%(01 No.)Adequate rating power contactors , Overload relay, Single Phase preventer relay with under voltage & over voltage or as suitable(01 No), Flush mounting type ammeter 96 sqmm with selector switch suitable CT connection (01 No), Voltmeter 96 sqmm with selector switch (01 No), Indicating lamp for ON,OFF,TRIP(03 Nos),Indicating lamp for R,Y,B (03 Nos) without transformers oilas follows: (1) Switch fuse unit 125 A TPN with handle FN 125 A-1 No.(2) HRC fuse 125 A-3 Nos (3) Star contactor coil voltage 240AC with 2 No +2NC AUX. contacts Block MNX 50- 1No.(4)TAP contactor coil voltage 240AC with 2 No +2NC AUX. contacts Block MNX 50- 1No.(5)Line contactor coil voltage 240AC with 2 No +2NC AUX. contacts Block MNX 50- 1No.(6) Over load relay range -A CT operated 45-75 A MN5-01 No(7) Current Transformer 15 VA , CL. 1 for Metering 100//5A-3 No.(8) Push button start/stop element 22.5 mm dia -2 Nos(9) Indicating lamps 230V AC Red LED Type -3 No(10) MCB 6A 1P MCB , 10 KA -1 No.(11) On Delay Timer 0-30 Sec , Coil voltage 240 V , AC 2AODTS-3 Nos(12) Ammeter ,0-100/5a,(100-600A) Sappress Scale 6-Time,96 Sq. mm with Ameter Selector switch 0-100/5A-1 No . (13) Voltmeter 0-500 V ,96 SQMM size with voltage selector S96-1 No.(14) Single Phase preventer relay with under voltage S2VMR2 1 No 55 OD828/2024-2025:SITC ofPump- Non clog sewage solid handling - Suc/Del size 150 mm x 150 mm head 15 mtr & discharge 400 m3/hr , Body-CI, Impeller -SS, Shaft- EN-8, Sleeve-SS with coupling, base frame, fuel tank & leads coupled with38 BHP diesel engine,1500 RPM , Self start, water cooled with radiator complete with 12 V battery as required 56 OD829/2024-2025:SITC of 4 pole 320 Amp oFF load side handle change over switch conforming to IS: 13947 (Part I & III) in sheet steel enclosure i/c connection etc. complete as required.

Key Value

Document Fees
INR 590 /-
EMD
INR 88602.0 /-
Tender Value
INR 44.11 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail