}

Tender For Balance Work For Renovation And Beautification Of Govt. I.T.I. Campus Sahajahanpur District-Sahajahanpur., 1 Balance Work For Renovation And Beautification Of Govt. I.T.I. Campus Sahajahanpur District-Sahajahanpur 2 Cement Concrete Flooring, Shahjahanpur-Uttar Pradesh

Government Departments has published Tender For Balance Work For Renovation And Beautification Of Govt. I.T.I. Campus Sahajahanpur District-Sahajahanpur., 1 Balance Work For Renovation And Beautification Of Govt. I.T.I. Campus Sahajahanpur District-Sahajahanpur 2 Cement Concrete Flooring. Submission Date for this Tender is 05-10-2024. Brushes Tenders in Shahjahanpur Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

45434760
Tender For Balance Work For Renovation And Beautification Of Govt. I.T.I. Campus Sahajahanpur District-Sahajahanpur., 1 Balance Work For Renovation And Beautification Of Govt. I.T.I. Campus Sahajahanpur District-Sahajahanpur 2 Cement Concrete Flooring
Open Tender
Indian
Uttar Pradesh
Shahjahanpur
05-10-2024

Tender Documents

Tender Details

Tender For Balance Work For Renovation And Beautification Of Govt. I.T.I. Campus Sahajahanpur District-Sahajahanpur., 1 Balance work for Renovation and Beautification of Govt. I.T.I. Campus Sahajahanpur District-Sahajahanpur 2 Cement concrete flooring 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 12-20mm nominal size laid in one layer neat cement (25 mm thick floor). 3 Cement plaster skirting up to 30 cm height, with cement mortar 1:3(1 cement : 3 coarse sand), finished with a floating coat of neat cement.18 mm thick 4 Supply of glass strips for flooring.40mm wide & 4 mm thick 5 12 mm cement plaster in single coat on rough side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement : 6 coarse sand 6 12mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or roundedangles not exceeding 80mm in girth and finished even and smooth no extra for mixing any additive. (1)1 cement : 6 coarsesand. 7 M-150 brick work in 1:6in super-structure above plinth level up to floor two level ( up to two storeys ) includingnecessarycutting and moulding of brick work asrequiredand also including honeycombed brick work in thickness of wall more than 12cms. (1:6 cement : coarse sand) 8 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters : 35 mm thick Single leaf 9 Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes 10 Providing and fixing fly proof galvanized M.S. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm all completeWith 12 mm mild steel U beading 11 Steel work inbuilt uptublartrusses includingcutting, hoisting, fixingin position andapplying a priming coat of approvedsteelprimer,elded and bolted including specialshappedwashersetc. complete: Electric resistance or induction butt welded tubes. 12 Steel Painting:Applying priming coat:(a) With ready mixed red oxide zink chromate primer of approved brand and manufacture on steel galvanised iron/steel works.(b) Painting withsynthetic enamel paint of approvedbrandand manufactureto give an even shade:Two or more coats on new work. 13 Steel Painting:Applying priming coat:(a) With ready mixed red oxide zink chromate primer of approved brand and manufacture on steel galvanised iron/steel works.(b) Painting withsynthetic enamel paint of approvedbrandand manufactureto give an even shade:Two or more coats on new work. 14 Finishing walls with Acrylic smooth exterior paint of required shade: - New work (Two or more coat applied @ 1.67 Ltr./10 Sqm over and including base coat of water proofing cement paint applied @ 2.20 kg/10 Sqm. 15 One priming coat of cement primer and Two coat oil distemper on new work including supply of all materials labour and tools and plants etc required for proper completion of the work 16 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 17 Scraping old white or colour wash including disposal of refuse as directed by the Engineer-in- charge with in a distance of 60 mts.(200 ft) 18 Supplying and fixing rolling shutters of approved make made of required size of M.S. laths interlocked together througgh their intire length and jointed together at the end by end locks mounted on specially designed pipe shall with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete including the cost of providing and fixing necessary 27.5cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS:4454 part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25m M.S. Laths with 1.25mm thick top cover 19 Supply & fixing of Hi Rrib profiled sheeting 1000-1030 cover width, 28/30mm crests @250-255mm c/c manufactured out of 0.55mm TCT hi-tensile Multi cloured galvalume steel (AZ-150gsm Aluminium zinc allo y metallic coating of total both sides 550 Mps yield stress as pler AS-1397).The sheet shall have wide pans with 3small stiffening ribs for effective water shedding and special male/ female ends with full return legs on side laps for purlin support.The male end of the sheet shall have anti capillary flute at side lap to prevent leakages.The shheet shall be passivated and clear resin coated.The sheet shall be fixed by means of galvanised self drillingg self taping fasteners (12.14x55 with EPDM seals)The sheet shall be suplied in lengths maximum upto 6.12 Mtrs long to suit side dimensions Supply and fixing of Multi coloured galvanise roof sheet with screws on laid area basis. 20 Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete (Ridges plain (500 - 600mm) 21 Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete Gutter (600 mm over all girth) 22 Providing & fixing MS rain water pipe 100x125mm of approved make in position as per drawings or as directed by Engineer in charge 23 Dismintling Roof Sheet 24 Dismantling of existing plaster including disposal of refuse as directed by the engineer in charge 25 Dismantling cement concrete or brick or granolithic floors including base concrete and including stacking of dismantled materials as directed by the Engineer-in-charge within a distance of 60 metre (200 feet). 26 Disposal of Malba upto 5 Km 27 Providing and fixing double scaffolding system (cup lock type) onthe exterior side of building/structure, upto 25 metre height, aboveground level, including additional rows of scaffolding in stepped manneras per requirement of site, made with 40mm dia M.S. tube, placed1.5 metre centre to centre, horizontal & vertical tubes joint with cup& lock system with M.S. Tubes, M.S. tube challis, M.S. clamps andstaircase system in the scaffolding for working platform etc. andmaintaining it in a serviceable condition for execution of work ofcleaning and/ or pointing and/ or applying chemical and removing itthereafter. The scaffolding systemshall be stiffened with bracings,runners, connecting with the building etc, wherever required, if feasible, for inspection of work at required locations with essential safetyfeatures for the workmen etc., complete as per directions and approvalof Engineer-in-charge 28 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular type switch, modular plate, suitable size G.I. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. 29 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular type switch, modular plate, suitable G.I. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. 30 Wiring for circuit/sub-main wiring along with earth wire with the following size of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVCconduit as required. 31 2X1.5 sqmm + 1x1.5 sqmm earth wire 32 2X2.5 sqmm + 1x 2.5 sqmm earth wire 33 2X4.0 sqmm + 1x 4.0 sqmm earth wire 34 2X6.0 sqmm + 1x 6.0 sqmm earth wire 35 4X10 sqmm + 2x 6.0 sqmm earth wire 36 4X16 sqmm + 2x 6.0 sqmm earth wire 37 Supplying and drawing following pair 0.5 sqmm FRLS PVC insulated annealed copper conductor, unarmoured telephone cable in the existing surface/recessed steel/PVC conduit as required. 2 Pair 38 Supplying and drawing co-axial TV cable RG-6 graded, 0.7 mm solid copper conductor PE insulated,shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. 39 Supply and fixing of following size of PVC conduit alongwith the accessories in recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required: 25mm 40 Supplying and fixing following modular switch/ socket on theexisting modular plate & switch box including connections but excluding modular plate etc as required. 41 Telephone socket outlet 42 TV antenna socket outlet 43 Bell Push 44 Supply and fixing of stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 45 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. 46 Supplying and fixingfollowing size/modules, GI box along with modular base& cover plate for modular switches in recess etc as required.1 or 2 module(75mm X 75 mm ) 47 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch,connection etc. as required. 48 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch,connection etc. as required. 49 Supplying and fixing 3 pin 5 A ceiling rose on the existing junction box/woodedn block including connectionetc. as required. 50 Supplying and fixing brass batten/angle holder including connectionetc. as required. 51 Instalation,testing & commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLSCFL/LED lamps per fitting, complete with all accessories including connection etc. as required. 52 Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. 53 Installation, testing and commissioning of prewired, flourescent fitting / compact fluorescent fitting of all types, complete with all accessories and tubes etc. directly on ceiling / wall, including connection with 1.5 sq. mm. PVC insulated, copper conductor, single core cable etc. as required. 54 Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc.Including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. 55 Numbering of ceiling fan/exhaust fan/fluorescent fittings as required. 56 Installation of exhaust fan in the existing opening, including making good the damage, connections, testing, commissioning etc. as required.upto 450 mm sweep. 57 Extra for fixing the louvers / shutters complete with frame fro exhaust fans of all sizes. 58 Providing and fixing circular/Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/M.S. sheet box by means of 3.3 mm dia round headed screwed, one loc at the conrners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. 59 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Disect Current(BLDC) motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value(CM/M/W) minimum 6, Air delivery minimum 210 Cum/Min, 350 RPM(tolerance as per IS: 374-2019), THD less than 10% remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise= 75 degree C(max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 60 Supplying and fixing followingway, single pole and neutral sheet steel, MCB distribution board, 240 V on surface /recess completewith , tinned copper busbar, neutral busbar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (But without MCB / RCCB / Isolators). 8 way,Double door 61 Supplying and fixing followingway, Horizontal type three pole and neutral MCB distribution board, 415 volts on surface /recess completewith , tinned copper busbar, neutral busbar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (But without MCB / RCCB / Isolators).6 way (4 + 18), Double door 62 Supplying and fixing followingway, surface/recess mounting,vertical type 415V, TPN MCB distribution board, on steel sheet, dust protected, duly power painted, inclusive of 200 A tinned copper busbar, common neutral link, earth bar, din bar, for mounting MCBs (But without MCBs and incomer)as required(Note:vertical type MCB TPDB is normally used where 3 phase outles are required.) 4 way (4 + 12), Double door 63 Supplying and fixing 5 amps. to 32 amps. rating, 240 volts `C series,miniature circuit breaker (MCB) suitable for inductive load offollowingpolesin the existingMCBDBcomplete with connections, testing andcommissioning etc. as required. 64 Single Pole 65 Double Pole 66 Supplying and fixing single pole, blanking plate in the existing MCB DB complete etc. as required. 67 Supply and fixing 20 amp, 240 volts, SPN industrial Type, socket outlet ,With 2 pole and earth ,metalenclosed plug top along wth 25/32 amp. `C` series SPMCB , in sheet steel encosure, on surface or in recess with chained metal cover for the socket out letand complete with connections, testing and commissioning etc. as required. 68 Providing and fixing M.V. danger notice plate of 200 mmx150 mm, made of mild steelm at least 2 mm thick, and viterous enameled whithe on bothe sides, and with incription in single red colour on front side as required. 69 Suplying and fixing cable end box(Loose Wire Box) suitable for following triple pole and neutral, sheet steel, MCB distribution borad, 415 Volts, on surface/recess, complete with testing and commissoning ect. As required. For 6 way, Double Door TPNMCBDB 70 Supply and installing of following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, jointed with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required 450mmwidth x 62.5mm depth x 2.0mm thickness 71 Earthing with GI earth pipe, 600 mm X 600 mm X 6 mm thick including accessories and providing masonary enclosure withcover platehavinglockingarrangement and watering pipe of 2.7 metre long etc, with charcoal/cock and salt as required. 72 Supplying and Laying of 25 mm X 3 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection / terminating with nut, bolt, spring, washer etc. as required.( jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) 73 Supplying and Laying of 6 SWG G.I wire at 0.50 metre below ground level for conductor earth electrode, including connection /terminating with G.I. thimble etc. as required. 74 Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. 75 Upto 35 sq. mm 76 Above 35 sq. mm and Upto 95 sq. mm. 77 Above 185 sq. mm and Upto 400 sq. mm. 78 Supplying & making end termination with brass compression gland and aluminium lugs for the following size of PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 79 2 X 10 sqmm. (19mm) 80 4 X 10 sqmm. (25mm) 81 3.5 X 70 sqmm. (38mm) 82 3.5 X 240 sqmm. (62mm) 83 Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep) and refilling etc as required. 100 mm Dia 84 Supply of following size of 1.1 KV grade multicore aluminium conductor PVC sheathed armoured cable as per IS 1554. Make-Polycab or Eq 85 10 sqmm 2 core 86 10 sqmm 4 core 87 70 sqmm 3.5 core 88 240 sqmm 3.5 core 89 L.T. PANEL 90 Supply, & Erraction of factory fabricated & wired metal clad dust and vermin proof floor mounted,M.S. channel base with bottom and top cable entreis electrical control panel with TPN MCCBs (four pole 36 KA with thermal magnatic release ) switches complete and instrument chamber etc. complete in all respects. the instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase votage and single phase voltage, current and other parameters (KVA,PF,KW etc) in each phase with touchtype selector switches for different reading instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic aluminium basbar as per IS 8623 or above insulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. the MCCBs shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc.the job includes the grounting of the board as per directions of Engineer-incharge. All out going of 100 Amp and above shall have an Ammeter. the panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm. cubicle type switch board shall be of cat A & B only. 91 Incoming : 92 400 Amp. MCCB - 1No 93 Metering : 94 One (1) No. (0-500V) 96 x 96 Sqmm voltmeter with control fuse & selector switch. 95 One (1) No. (0-400A) 96 x 96 Sqmm CT operated Ammeter with selector switch, CTs etc. 96 One (1) Set of Phase Indication Lamp. 97 Bus Bar : 98 One (1) No.500 A, TPN aluminimum bus bar of suitable length. 99 Outgoing : 100 Phase indication lamps on each outgoing to be provided. 101 200Amp 4P MCCB - 1Nos. 102 63Amp 4P MCB - 5Nos. 103 40Amp 4P MCB - 4Nos. 104 32Amp SP MCB - 2Nos. 105 100Amp 4P MCCB - 1Nos.-Spare 106 40Amp 4P MCB - 1Nos.-Spare 107 63Amp 4P MCB - 1Nos.-Spare 108 Supply of1X17 W mirror light complete in all respects. Make-Philips or Eq 109 Supply of12 W LED BULB complete in all respect. Make-Philips or Eq 110 Supply ofLED Tube Light with batten suitable for up to 1X20 watt LED tube light complete including tube etc. on surface/Pendent complete in all respect.Make-Philips or Eq 111 Supply of Pendent mounting having 1X4 size 40 Wattseamlessly interateds LED luminiew with acrylic sheet diffuser and intergral electronic driver complete in all respects.Make-Philips or Eq 112 Supply of 36 Watt above 3300 leumin indoor Recess mounting LED Square Fitting for Armstrong Ceiling having Powder coated die cast aluminium housing withextendedheat sink and diffuser of Special Polycarbonate meterial and driver set complete in all respect.Make-Philips or Eq 113 Supply of recess/Surface/Pendent mounting round 10 to 15 watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/Reflector and driver set complete in all respects.Make-Philips or Eq 114 Supplyof AC 230/250 Volts, 50 Hz 55w 1400 rpm exhaust fans including providing nuts, bolts, mounting frame and other accessories including connections etc. complete as required.Make: Havells-STANDARD -Refresh Air-SPS 300mm sweep. 115 Supply and fixing following rateing four pole, 415 V, MCB in the existingMCBDBcomplete with connections, testing andcommissioning etc. as required. 116 40 A,4P MCB-Bracking Capacity-10 kA, C-Curve-Make-Havells 117 63 A,4P MCB-Bracking Capacity-10 kA, C-Curve-Make-Havells 118 S/f of 20/30 pair Junction Boxes for Floors and building with Krone connectors, with connection and punching of same 119 Providing and laying cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) including supply of all materials, labour T & P rtc required for proper completion of the work and curing complete also including cost of formwork in foundation & floors. 120 Cement concrete flooring 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 12-20mm nominal size laid in one layer neat cement (25 mm thick floor). 121 Cement plaster skirting up to 30 cm height, with cement mortar 1:3(1 cement : 3 coarse sand), finished with a floating coat of neat cement.18 mm thick 122 Supply of glass strips for flooring.40mm wide & 4 mm thick 123 12 mm cement plaster in single coat on rough side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement : 6 coarse sand 124 12mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or roundedangles not exceeding 80mm in girth and finished even and smooth no extra for mixing any additive. (1)1 cement : 6 coarsesand. 125 12mm thick plaster in 1:3 on ceiling and soffitsof stairs upto floor two level. 126 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters : 35 mm thick Single leaf 127 Mild steel or iron work of small sizes and sections such as holding down bolts, hold fast tierods,gratings etc. ( when not included in an over all rates) wrought to required from including supply of steel and its wastage including cost of bolts, nuts if required for and welding, grinding and making holes as required completion of work fabrication of holes doors, chaukhats nosing. 128 Fabrication of holdfast for door, chaukhats and windows. 129 Providing & fixing of door / windows grill. 130 Z-Section steel windows with Openable panels, excluding Glass panes. 131 Angle iron chaukhat (40x40x5) 132 Fixing of Door, windows / ventilators chaukhats in position. 133 (a) Door chaukhats 134 (b) Window chaukhats 135 Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes 136 Providing and fixing Stainless steel sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868),transparent or dyed to required colour or shade, with nuts and screws etc. complete. (a) 250mm x 16mm. 137 Providing and fixing Stainless steeltower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete 138 300 x 10mm 139 200 x 10mm 140 Providing and fixing Stainless steelhandles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete (a) 125 mm. 141 Providing and fixing fly proof galvanized M.S. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm all completeWith 12 mm mild steel U beading 142 Steel Painting:Applying priming coat:(a) With ready mixed red oxide zink chromate primer of approved brand and manufacture on steel galvanised iron/steel works.(b) Painting withsynthetic enamel paint of approvedbrandand manufactureto give an even shade:Two or more coats on new work. 143 Steel Painting:Applying priming coat:(a) With ready mixed red oxide zink chromate primer of approved brand and manufacture on steel galvanised iron/steel works.(b) Painting withsynthetic enamel paint of approvedbrandand manufactureto give an even shade:Two or more coats on new work. 144 Finishing walls with Acrylic smooth exterior paint of required shade: - New work (Two or more coat applied @ 1.67 Ltr./10 Sqm over and including base coat of water proofing cement paint applied @ 2.20 kg/10 Sqm. 145 One priming coat of cement primer and Two coat oil distemper on new work including supply of all materials labour and tools and plants etc required for proper completion of the work 146 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 147 Scraping old white or colour wash including disposal of refuse as directed by the Engineer-in- charge with in a distance of 60 mts.(200 ft) 148 Dismantiling Door & window ,chowkhats with hold fast & including stacking of dismantled materials as directed by the engineer-in-charge with in a distance of 60 m (200ft) 149 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface withtrowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. e) The whole terrace so finished shall be flooded with water fora minimum period of two weeks for curing and for final test. All above 150 Dismantling jack arched or wooden beam & barges roof.including beam and roof concrete and including stacking of materials as directed byby the Engineer-in-charges with in a distanceof 60 meters(200ft.) 151 Dismantling of existing plaster including disposal of refuse as directed by the engineer in charge 152 Dismantling cement concrete or brick or granolithic floors including base concrete and including stacking of dismantled materials as directed by the Engineer-in-charge within a distance of 60 metre (200 feet). 153 Disposal of Malba upto 8 Km 154 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion . (i) Single socketed pipes. 110mm diameter 155 Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, punning, rounding the edges and making and finishing the outlet complete. 156 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110mm 157 Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. 158 Providing & fixing G.I. pipes complete with G.I. fittings & clamps including cutting & making good the walls etc. (internal work) Exposed on wall 25mm dia nominal bore 159 Painting G.I. pipes and fittings with two coats of anti corrosive bitumastic paint of approved quality. 25mm dia nominal bore. 160 Wiring for circuit/sub-main wiring along with earth wire with the following size of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVCconduit as required. 161 2X1.5 sqmm + 1x1.5 sqmm earth wire 162 2X2.5 sqmm + 1x 2.5 sqmm earth wire 163 2X4.0 sqmm + 1x 4.0 sqmm earth wire 164 2X6.0 sqmm + 1x 6.0 sqmm earth wire 165 Supplying and fixing following modular switch/ socket on theexisting modular plate & switch box including connections but excluding modular plate etc as required. TV antenna socket outlet 166 Supply and fixing of stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 167 Instalation,testing & commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLSCFL/LED lamps per fitting, complete with all accessories including connection etc. as required. 168 Installation, testing and commissioning of prewired, flourescent fitting /compact fluorescent fitting of all types, complete with all accessories and tubes etc. directly on ceiling / wall, including connection with 1.5 sq. mm. PVC insulated, copper conductor, single core cable etc. as required. 169 Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc.Including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. 170 Numbering of ceiling fan/ exhaust fan/ fluorescent fittings as required. 171 Installation of exhaust fan in the existing opening, including making good the damage, connections, testing, commissioning etc. as required.upto 450 mm sweep. 172 Extra for fixing the louvers / shutters complete with frame fro exhaust fans of all sizes. 173 Supply and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, `C` curve including connections, painting etc. as required. 174 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Disect Current(BLDC) motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value(CM/M/W) minimum 6, Air delivery minimum 210 Cum/Min, 350 RPM(tolerance as per IS: 374-2019), THD less than 10% remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise= 75 degree C(max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 175 Supplying and fixing followingway, single pole and neutral sheet steel, MCB distribution board, 240 V on surface /recess completewith , tinned copper busbar, neutral busbar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (But without MCB / RCCB / Isolators). 12 way, Double door 176 Supply & fixing of7/9 W LED BULB complete in all respect. 177 Supply and fixing of LED Tube Light with batten suitable for up to 1X20 watt LED tube light complete including tube etc. on surface complete in all respect. 178 12 mm cement plaster in single coat on rough side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement : 6 coarse sand 179 12mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or roundedangles not exceeding 80mm in girth and finished even and smooth no extra for mixing any additive. (1)1 cement : 6 coarsesand. 180 12mm thick plaster in 1:3 on ceiling and soffitsof stairs upto floor two level. 181 Steel Painting:Applying priming coat:(a) With ready mixed red oxide zink chromate primer of approved brand and manufacture on steel galvanised iron/steel works.(b) Painting with synthetic enamel paint of approved brand and manufactureto give an even shade:Two or more coats on new work. 182 Steel Painting:Applying priming coat:(a) With ready mixed red oxide zink chromate primer of approved brand and manufacture on steel galvanised iron/steel works.(b) Painting withsynthetic enamel paint of approvedbrandand manufactureto give an even shade:Two or more coats on new work. 183 Finishing walls with Acrylic smooth exterior paint of required shade: - New work (Two or more coat applied @ 1.67 Ltr./10 Sqm over and including base coat of water proofing cement paint applied @ 2.20 kg/10 Sqm. 184 One priming coat of cement primer and Two coat oil distemper on new work including supply of all materials labour and tools and plants etc required for proper completion of the work 185 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 186 Scraping old white or colour wash including disposal of refuse as directed by the Engineer-in- charge with in a distance of 60 mts.(200 ft) 187 Dismantling of existing plaster including disposal of refuse as directed by the engineer in charge 188 Disposal of Malba upto 8 Km 189 Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. 190 Upto 35 sq. mm 191 Above 35 sq. mm and Upto 95 sq. mm. 192 Above 185 sq. mm and Upto 400 sq. mm. 193 Supplying & making end termination with brass compression gland and aluminium lugs for the following size of PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 194 2 X 10 sqmm. (19mm) 195 4 X 10 sqmm. (25mm) 196 3.5 X 70 sqmm. (38mm) 197 3.5 X 240 sqmm. (62mm) 198 Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep) and refilling etc as required. 100 mm Dia 199 Supply of following size of 1.1 KV grade multicore aluminium conductor PVC sheathed armoured cable as per IS 1554. Make-Polycab or Eq 200 10 sqmm 2 core 201 10 sqmm 4 core 202 70 sqmm 3.5 core 203 240 sqmm 3.5 core 204 GST Extra as applicable

Key Value

Document Fees
INR 17700 /-
EMD
INR 460000.0 /-
Tender Value
INR 2.30 Crore /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Notice 0 KB
Click here to download tender document Tender Document 0 KB
Click here to download tender document Tender Document 0 KB
Click here to download tender document Tender Document 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail