Tender For Shifting Of 11Kv/Lt/Transformer From Chikalwas To Kavita (Nh-76). (Phase-Ii) 3305, udaipur-Rajasthan

Government Departments has published Tender For Shifting Of 11Kv/Lt/Transformer From Chikalwas To Kavita (Nh-76). (Phase-Ii) 3305. Submission Date for this Tender is 04-10-2024. Electrification Work Tenders in udaipur Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

45390897
Tender For Shifting Of 11Kv/Lt/Transformer From Chikalwas To Kavita (Nh-76). (Phase-Ii) 3305
Open Tender
Indian
Rajasthan
Udaipur
04-10-2024

Tender Documents

Tender Details

Shifting Of 11Kv/Lt/Transformer From Chikalwas To Kavita (Nh-76). (Phase-Ii) 3305 , Item Code [11.2-2022]:Item Type [Electrical] :: Sub Item Code [11.2-2022 + 11.2.12.2]: Providing & Laying P.V.C. / Xlpe Insulated & P.V.C. Sheathed Arrmouredaluminiumcable Confirming To Is:1554 P-I / Is :7098 P - I Of 1.1 Kv Withh4- Grade Electrolyticaluminium Conductor Confirming To Is 8130 Of Purity >99.6 %, Round / Flat Strip Armouring Of Cables, Inner / Outer Sheath Confirming To Is:5831In Existing Rcc / Hume / Stoneware / Pvc Pipe/ Open Duct/Cable Trench / Cable Tray(With Cable Tie) Includingtesting Etc. As Required Of Following Size. Oem Must Have Its Own In House Nabl Accrediated Laboratory For Testing Procedure As Per Is:10810.For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 185.0 Sq. Mm 3.5 Core , Item Code [12.12-2022]:Item Type [Electrical] :: Sub Item Code [12.12-2022 + 12.12.7]: P / L Of Double Wall Corrugated Hdpe Pipe Confirming To Is : 16205 P-24, Stiffness Class 750 N, Externally Corrugated And Having Smooth Surface Inside With Hdpe Coupler, Elbow, Tee At Required Depth Below The Ground For Laying Cable Of Following Nominal Outer Dia. Mfr Test Report From Nabl Accrediated Is To Be Submitted.(Excavation Of Earth & Back Filling With Compaction Is To Be Paid Extra)All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached With This Bsr 160Mm Dia , Item Code [13.1-2022]:Item Type [Electrical] :: Sub Item Code [13.1-2022 + 13.1.4]: Providing & Laying Xlpe Insulated Three Core Armouredaluminiumcable For Working Voltage 11 K.V.(E) Confirming Is :7098 P - 2Withh4- Grade Electrolyticaluminium Conductor Confirming To Is: 8130 Class-2 Of Purity >99.6 %, Insulation Screening: Extruded Semiconducting Compound Followed By Helically Wrapped Copper Tape, Round / Flat Strip Armouring Of Cables , Inner / Outer Sheath Pvc Type St-2 Confirming To Is:5831In Existing Rcc / Hume / Stoneware / Pvc Pipe/ Open Duct/Cable Trench / Cable Tray Includingtesting Etc. As Required Of Following Size. Oem Must Have Its Own In House Nabl Accrediated Laboratory For Testing Procedure As Per Is:10810 All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work, Refer Annexure A Attached With This Bsr . 3 Core 185.0 Sq.Mm , Item Code [13.12-2022]:Item Type [Electrical] :: Sub Item Code [13.12-2022 + 13.12.2.3]: Providing & Making Heat Shrinkable Typeindoor / Outdoor / Straight Through Terminations/ Joint Kitsuitable For11 Kv / 33 Kv (Earthed) Cable With Required Components, Prepration Of Cable Ends. Type Test Report Should Be As Per Is13573:2011 Which Covered All Sequence For Table 2 For Termination Kit And Table 3 For Streightthrough Joint Inclusive Thermal & Dynamic Short Circuit Test, Humidity Test, Soil Fog Test. Crosslinking Shall Be Done Out Side Factory With E- Beam/ Peroxide Technology. Extrusion Process Shall Be In House Oem Within Same Vicinity. Includingtesting Etc. As Required Of Following Sizes. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work, Refer Annexure A Attached With This Bsr . 11 Kv End Termination Kit Outdoor Type 3 Core 120/150/185 Sq.Mm , Item Code [14.7-20-22]:Item Type [Electrical] :: Sub Item Code [14.7-20-22 + 14.7.9]: Supply & Laying Following Size Bclass , G.I. Pipe Confirming To Is : 1239 P - 1 ( 2004 ) With Accessories Like Bend, Socket Etc. For Laying Earth Conductor/ Strip / Cable In Ground/ Surface/ Recess As Required. All As Per Pre Approved By Engineer In Charge. (Earth Excavation Will Be Paid Extra)All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached With This Bsr .100 Mm Dia , Item Code [19.1-2022]:Item Type [Electrical] :: Sub Item Code [19.1-2022 + 19.1.2]: Supply And Erection Of P.C.C. Pole As Per Rec Manual No 15/1979 (Ammended Upto Date) And As Per Latest Discom Specifications With Factor Of Safety 2.5Including Excavation Of Pit Upto Pole Planting Depth 1/6Th Of Pole Length. And Back Filling With Stone Aggregate/Boulders And Soil By Ramming And Watering Etc Complete As Required. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 9.0 Mtr Long Pcc Pole Of 200 Kg Working Load , Item Code [19.10-2022]:Item Type [Electrical] :: Supply And Fixing Of 11 Kv Pin Insulator Confirming To Is:731:1971 With Latest Ammendmenton Existing Bracket Including All Accessories Like Ms Forged Hot Dipped Gi Pin Confirming To Is 2486(Part-I)/1993 & Is:2486 (Part-Ii)/1989 With Latest Amendment, And As Per Latest Discom Specs. Etc. As Required. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr , Item Code [19.11-2022]:Item Type [Electrical] :: Sub Item Code [19.11-2022 + 19.11.1]: Supply And Fixing Of 11Kv Disc Insulator And Hot Dipped Galvanized Hardware Confirming To Is:731:1971 With Latest Ammendment And As Per Latest Discom Specs. On Existing Bracket Including All Accessories Etc. As Required. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr B & S Type Hardware 45 Kn , Item Code [19.11-2022]:Item Type [Electrical] :: Sub Item Code [19.11-2022 + 19.11.3]: Supply And Fixing Of 11Kv Disc Insulator And Hot Dipped Galvanized Hardware Confirming To Is:731:1971 With Latest Ammendment And As Per Latest Discom Specs. On Existing Bracket Including All Accessories Etc. As Required. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr B & S Disc Insulator 45 Kn , Item Code [19.13-2022]:Item Type [Electrical] :: Supplying And Layingof Hot Dip Galvanized Steel Stay Wire Of 550-900 N/Mm Quality Confirming To Is-2141/2000 In All Respect Including Chemical Composition (Heavily Coated Hard Quality) Of Dia 7/3.15 Mm(7/10 Swg) And As Per Latest Discom Specs. Etc. As Required. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr , Item Code [19.14-2022]:Item Type [Electrical] :: Sub Item Code [19.14-2022 + 19.14.1]: Supply And Fixing Of 11 / 33. Kv Stay Insulator As Per Is:5300/1969 And As Per Discoms Standard Specifications Etc. As Required. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 110 X 75 X 22Mm 11 Kv Stay Insulator , Item Code [19.15-2022]:Item Type [Electrical] :: Sub Item Code [19.15-2022 + 19.15.1]: Supply And Fixing Of Lt Distribution Kiosk Confirming To Is:13947/1993/ Iec 60947 Pt.3 Amended Up-To-Date And As Per Discomspecifications Made Of 2 Mm Thick Powder Coated Crca Sheet Of 415 Volts 3 Phase 4 Wire Triple Pole And Neutral Type, Complete In All Respect As Required. Including Incoming Switch Disconnector Fuse Unit, Aluminium Busbar With Copper One Piece U Contacts Base, Brass Studs And Nuts, Copper Busbar For Main And Interconnection, Ms Channel Frame Of 75 Mm X 40 Mmgrouted With C.C. Of M-10 Grade To Achieve The Height Of 1.5 Feet Above The Road Level Suitable For Required No.Outgoing. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 200 Amp. Lt Distribution Kiosk For 63/100 Kva Transformer , Item Code [19.17-2022]:Item Type [Electrical] :: Supply And Fixing Of 100 Amp, 11Kv Horn Gap Fuse Set Is 9385 On Existing Dp Structure With 6 Nos 24Kv/22Kv Post Insulator (Is:5350 Part Iii), Hot Dipped Hard Ware,Fuse Wire Of Required Size Etc. Complete In All Respect As Per Discom Specification Etc. As Required.All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products/ Work, Refer Annexure A Attached With This Bsr . , Item Code [19.18-2022]:Item Type [Electrical] :: Supply And Fixing Of 11Kv, 400 Amp 3 Pole, Central Pot Rotating Double Break Type Isolator (Is:9921 Part I Tov) Without Earth Blade Operating Mechanism With Gi Spring Loaded Reverse Loop Type Fixed Contact, Solid Hard Drawn Electolytic Copper Tubular Moving Contact With Silver/ Nickel Plated At End Points, 9 Nos Post Insulator Of 12 Kv (Is:2554 & Is 5350 Part Iii), Hot Dipped Galvanising Hard Ware, Nut, Bolts Etc Complete In All Respect As Per Discom Specification Etc. As Required. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products/ Work, Refer Annexure A Attached With This Bsr . , Item Code [19.2-2022]:Item Type [Electrical] :: Sub Item Code [19.2-2022 + 19.2.2]: Supply And Erection Of Gi Stay Set Confirming To Pattern-1 Of Bs:16/1974 And As Per Latest Discom Specifications Complete With Stay Rod With Anchor Plate Fitted With Cast Iron Cross Head And Steel Bow, In Cement Concrete 1:3:6 Including Excavation Of Pit-Re-Filling Etc Complete As Reqd. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr Stay Set Of Dia 16Mm, 1.8M Long Stay Rod And Anchor Plate 300 X 300 X 4.0 Mm , Item Code [19.20-2022]:Item Type [Electrical] :: Supply And Fixing Substation Structure For Mounting 11/0.4 Kv Transformer On Double Poleas Per Discom Specification Complete In All Respect As Required Including Nuts And Bolts Etc (Excluding The Cost Of Poles) Made Of Ms Channel Of 4 Nos 100 X 50 X 6Mm And 4 Nos 75 X 40 X 6Mm And Ms Flat 50 X 6Mm Etc. As Required. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products/ Work, Refer Annexure A Attached With This Bsr . , Item Code [19.22-2022]:Item Type [Electrical] :: Providing And Fixing Of Single Pole Mounted Substation Structure Set For Isolator / Single Phase Transformer As Per Discom Specification Complete In All Respect With Nuts And Bolts As Required Ms Flat 50 X 6Mm, Ms Angle 65 X 65 X6mm, Ms Channel 100 X 50 X 6Mm. ( Excluding Cost Of Pole ). Etc. As Required. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products/ Work, Refer Annexure A Attached With This Bsr . , Item Code [19.24-2022]:Item Type [Electrical] :: Sub Item Code [19.24-2022 + 19.24.6]: Supplying And Drawing Ofxlpe Insulated Lt Aerial Bunched Aluminium Conductor Cable Confirming To Is 14255/1995 And Is 398 (Pt-4)/ 1994 And As Per Discom Specs. On Existing Cross Arms Through I Hook With All Necessary T&P Required Including Binding And Twisting Etc. Complete In All Respect As Required. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products/ Work, Refer Annexure A Attached With This Bsr .3 X 25 Sq. Mm. + 1X25 Sq. Mm. (Insulated) , Item Code [19.25-2022]:Item Type [Electrical] :: Supply & Erection Ofm S Lattice Structure Of Height 12.8 Mtr As Per Discoms Approved Design & Details In Alignment, Including Painting Of Tower Of Approved Make Two Coat Of Red Oxide Paint And One Coat Of Aluminium Paint Before Installation And One Coat Of Aluminium Paint After Erection Work Completed As Per Technical Specifications & Drawing Of Discom.(Excavation Of Pit Pcc And Cc Foundation As Per Discom Specs. To Be Paid Extra). All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products/ Work, Refer Annexure A Attached With This Bsr . , Item Code [19.26-2022]:Item Type [Electrical] :: Supply & Erection Ofm S Lattice Structure Of Height 11.0 Mtr As Per Discoms Approved Design & Details In Alignment, Including Painting Of Tower Of Approved Make Two Coat Of Red Oxide Paint And One Coat Of Aluminium Paint Before Installation And One Coat Of Aluminium Paint After Erection Work Completed As Per Technical Specifications & Drawing Of Discom.(Excavation Of Pit Pcc And Cc Foundation As Per Discom Specs. To Be Paid Extra) All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products/ Work, Refer Annexure A Attached With This Bsr , Item Code [19.32-2022]:Item Type [Electrical] :: Supply And Fixing Of Guard Bracket 2.2 Mtr. Long Made From (75X40) Ismc 7.14Kg. Per Mtr. M.S. Channel Including Necessary Clamp And Botlsetc. As Per Technical Specification & Drawing Of Discom. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products/ Work, Refer Annexure A Attached With This Bsr . , Item Code [19.34-2022]:Item Type [Electrical] :: Supply And Installation Of Spike Of M.S. Rod 20Mm Dia 3.0Mtr. Long For Earthing Of (Tower/Pole) Drive Into Earth By Mechanical Means Sturcture Connection The Spike With Cross Arm Top Hamper Pcc Pole, Lattics Tower To Earth Etc. Completeas Per Technical Specification Of Discom. , Item Code [19.35-2022]:Item Type [Electrical] :: Labour Charges For Dismentling The Structure With Pole Mounted Transformer Different Capacity Along With Distribution Boards And Re- Erecting The Transformer In The Structure To Be Newly Erected Along With Distribution Boards And Erecting Testing, Testing And Commissioning (As Well As Cabling) , Item Code [19.36-2022]:Item Type [Electrical] :: Labour Charges For Dismantling Ofexisting Electric Poles (Pcc Poles, Ms Channel, Lattic Tower 12.6Mtr. , 11 Mtr. Along With The Acsr Conductors, 11Kv/33Kv/Lt Line Etc. 11Kv Insulator Lt Insulatorguard Wires, Staywires And Other Electric Items Of The Pole Coming Along The Alignment Of The Road And Removal And Re- Rollingpcc Pole, Ms Channel Different Sizes As Well As Handing Over The Same To Discom Store Including Transportation From Site To Store And Stacking Of Dismantling Material In Store And As Per The Direction Of Engineer Incharge And Clean The Site Good As Per The Requirement And Submit The Receipt From Discom/ Concering Authority, Including All Complete Works. , Item Code [19.4-2022]:Item Type [Electrical] ::Sub Item Code [19.4-2022 + 19.4.1]: Supply And Fixing Of Lt Porcelain Pin Insulator As Per Is 1445-1997 And As Per Discoms Standard Specifications,Suitable For Working Voltage 1100 Volts Including All Accessories Like Ms Forged Gi Lt Pin Confirming Tois:7935/1975 (Latest Amended) Nut, Bolt Etc. As Required. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 100 Mm X 70 Mm , Item Code [19.5-2022]:Item Type [Electrical] :: Sub Item Code [19.5-2022 + 19.5.1]: Supply And Fixing Of Lt Porcelain Shackle Insulator As Per Is:1443 1979 And As Per Discoms Standard Specifications, Suitable For Working Voltage 1100 Volts Including All Accessories Like Gi Hardware Fittings Confirming Tois:7935/1975 (Latest Amended) Nut, Bolt Etc. As Required. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 75Mm X 90Mm , Item Code [19.6-2022]:Item Type [Electrical] :: Sub Item Code [19.6-2022 + 19.6.3]: Supplying And Drawing Overhead Steel Core Aluminium Conductor (Acsr) Isi Marked(Is 398 Part Ii-1996) On Existing Cross Arms Through Insulator With All Necessary T&P Required Including Binding And Twisting Etc. Complete In All Respect As Required. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 50 Sqmm Of (6+1) 3.35 Mm (Insulated Rabbit) For Lt , Item Code [19.6-2022]:Item Type [Electrical] :: Sub Item Code [19.6-2022 + 19.6.5]: Supplying And Drawing Overhead Steel Core Aluminium Conductor (Acsr) Isi Marked(Is 398 Part Ii-1996) On Existing Cross Arms Through Insulator With All Necessary T&P Required Including Binding And Twisting Etc. Complete In All Respect As Required. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 100 Sqmm Of (6/4.72 Mm+1/1.57 Mm) (Dog) , Item Code [19.7-2022]:Item Type [Electrical] :: Supply And Fixing Of V Type Cross Arms With Top Hamper And Clamps As Per Latest Discom Specifications Made Of Ms Angle On The Existing Poles Complete Including All Necessary Nut And Bolt, Clamps With Two Coats Of Red Oxide And Two Coats Of Aluminium Paint Etc. As Required. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr , Item Code [19.8-2022]:Item Type [Electrical] :: Sub Item Code [19.8-2022 + 19.8.1.1]: Supply And Fixing Of Top Hamper On The Existing Pole As Per Latest Discom Specifications Complete Including Nut Bolts With Two Coats Of Red Oxide And Two Coats Of Aluminium Paint Etc As Required. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr Vertical Type 11 Kv (.7M Long) (65 X 65 X6mm Angle) , Item Code [19.9-2022]:Item Type [Electrical] :: Sub Item Code [19.9-2022 + 19.9.2]: Supply And Fixing Of Ms. Channel Bracket With Clamp As Per Discom Specifications Including Nut, Bolt With Two Coats Of Red Oxide And Two Coats Of Aluminium Paint Etc. As Required. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 1.4 Mtr. Long , Item Code [23.24]:Item Type [Electrical] :: Sub Item Code [23.24 + 23.24.2]: Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement - All Work Up To Plinth Level 1:3:6 (1 Cement : 3 Coarse Sand (Zone-Iii) Derived From Natural Sources : 6 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources)

Key Value

Document Fees
INR 2000 /-
EMD
INR 374620.0 /-
Tender Value
INR 1.87 Crore /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Notice 0 KB
Click here to download tender document Tender Document 0 KB
Click here to download tender document Tender Document 0 KB
Click here to download tender document Tender Document 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail