| 1 | Supply, installed, commissioning and testing refrigerator electric driven (single phase) capacity310 ltr, double door , 230 volts and cool lock technology including tempered glass tray, pocket handle, great bottle storage space & bigger vegetable basket R-600 A compressor , inbuild voltage stablizer & 4 star rating complete all as specified and directed.Make:- LG/Samsung/Haier |
| 2 | Supply, installed, commissioning and testing refrigerator electric driven (single phase) capacity195 ltr, 230 volts and cool lock technology including tempered glass tray, pocket handle, great bottle storage space & bigger vegetable basket inbuild stablizer , & 4 star rating complete all as specified and directed.Make:- LG/Samsung/Haier |
| 3 | Supply, installation, commissioning and testing of water cooler partially stainless steel, electric driven single phase having approx storage and nominal cooling capacity of 60 ltrs & storage capacity of 120 ltrs water cooler complete all as specified and directed.Make :- Blue Star / Carrier |
| 4 | Supply, installation, commissioning and testing of water cooler partially stainless steel, electric driven single phase having approx storage and nominal cooling capacity of 40 ltrs & storage capacity of 80 ltrs water cooler complete all as specified and directed.Make :- Blue Star / Carrier |
| 5 | Supply, installation,commissioning of Glass Top Deep Freezer single phase 240 volt, 50 Hz 320 Ltr capacity complete all as specified and directed. |
| 6 | Supply and installation , commissioning & Testingwall mounted air cooled split units indoor/outdoor complete with cordless remote control unitelectric drive single phase of capacity 2 Ton, 5 star rated and with in built air ioniser and Plasma filter for better indoor air quality of capacity 2 TR complete with all accessories including makingall arrange ment for fixing indoor & outdoor units , making necessary hole with bracket in wall to pass tubing and cables and grounting bolt in wall , connecting suction & discharge of copper tubing and cables , copper tubing including cutting brazing, flaring and testing of size 1x4”x22SWG in required length as per siteincluding insulating piping & Gas Chargingcomplete all as specified & directed.Make :- Daikin/Ogeneral/Panasonic |
| 7 | Supply and installation , commissioning & Testingwall mounted air cooled split units indoor/outdoor complete with cordless remote control unitelectric drive single phase of capacity 1.5 Ton, 5 star rated and with in built air ioniser and Plasma filter for better indoor air quality of capacity 1.5 TR complete with all accessories including makingall arrange ment for fixing indoor & outdoor units , making necessary hole with bracket in wall to pass tubing and cables and grounting bolt in wall , connecting suction & discharge of copper tubing and cables , copper tubing including cutting brazing, flaring and testing of size 1x4”x22SWG in required length as per siteincluding insulating piping & Gas Chargingcomplete all as specified & directed. |
| 8 | Excavating in trenches not exc 1.5 m wide and not exc 1.5 m in depth for foundations, laying of pipes/cables/poles etc and getting out in soft/loose soilcomplete all as specified and directed. |
| 9 | Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm thick each layers as in soil complete all as specified and directed. |
| 10 | Removing excavated material/soil to a distacne not exc 50 m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specefied and as directed. |
| 11 | Supply & laying in trences GI Tubing15 mm bore medium grade with all fitting completeall as specified and as directed |
| 12 | M&L , Gun metal globe valve 15 mm with iron wheel head heavy duty screwed both ends for iron pipe for union , ISI markedcomplete all as specified & directed |
| 13 | Supply of MachineSupply, installation, testing and commissioning of Air Cooling Unit of size 6\" x6\" x6 feet made out of, 20 SWG,with 4 Inch thick honey padandMS angle section 50x6 mm, factory fabricated front openabledoor system suitable for 3 phase 4 wire 415 volts, powder coatedpainting the complete body internally and externally with two coats of synthetic enamel paint of approved colour over a coat of red oxide primer complete including necessary internal wiring with PVC insulated multistrand copper conductor singal core FRLSH cable ofsuitable sizeanddeliver fresh air, which circulate stale air,With power-saving technology,Reduce temperature , Auto drain /clean function and ,the pad shall completely cover the grill panel completely all as specified and as directed. : following features:(a ) High Speedsubmersible water pump 35 Watt , single phase240 Volt, maximum lifing of water 2.4 mtr , 0.5 HP , in build thermal over load protector-2 Nos Make- Vansal /Anand /AMDO (b) Fan motorhevy duty copper winding 1200 watt (1.5 HP) , Power 3 phaseMake- ALMONARD/ Merathan(c) Cellulose pad 100 mm thick, , As per OEM ,(d) Fan Type: fan size:- 36\" , RPM :-900, (e) Tank capacity 300 Ltr complete(f)Discharge of Air Flow - Top side(g)Air Pressure 150 P.A(h) Noise(db) - 73 db(j) Air outlet size-1066 mm x1066 mm all as specified and directed. |
| 14 | Supply and installation of GI, Pre fabricated rectangular GI ducts, of 24 SWG, Glavanised Iron Sheet thickness 0.70 mm complete with MS flanges and bracing (as specified), necessary supports using thread rods (as directed) and anchor bolts, supply air collars, vanes, splitterscomplete all as specified and directed. |
| 15 | Supply, installation,Exhaust air Square Grillof size 32\" x12 \" with damperwith multideflection ( Four Way Deflection) including making good disturbed surfacescomplete all as specified and directed. |
| 16 | Supply and fixing of 50 mm Thick Thermocoal / Ductinsulation 9 mm cross lean sheetalong with lack coating for protect the outside duct with two coats of enamel paint after surface preparation includingmaking good disturbed surfaces complete all as specified and directed. |
| 17 | Supply,& fixing of canvas Flexible Connection for Mouth opening of Air Cooler of size 1066 mm x1066 mm flexible typeto S.A. Ductcomplete all as specified and directed. |
| 18 | Supply, fabrication and installation of MS base frame of MS angle iron and flat iron of suitable size for Air Cooler & Water Tankunits complete with epoxy painting, vibration isolation pads, supports, rangers, railing, brackets etc with coats of epoxy primer and 2 supports of black point etc are required. complete all as specified and directed. |
| 19 | M & L for dismantling ofWall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillet including refixing after complete the ducting cooler work work complete all as specified and directed. |
| 20 | M & L for Non asbestos fibre cement building boards fixed or laid/ inserted to timber/GI/Aluminium framework with screws complete |
| 21 | M & L for civil work including core cut, chieseiling , cutting of walland making it as original by covering to all duct opening complete including making good disturbed surfacescomplete all as specified and directed. |
| 22 | Supply & fixing, Laying, jointing and testing LT under ground electric power cablecrossed linked polyethylene ( XLPE)insulated, galvanised steel strip or wire armoured,ISI-7098 Marked, with aluminium conductor multi stranded , heavy duty 1100 Volts grade of size 35 sqmm cross sectional area, 3.5 core complete all as specifiedand directed. |
| 23 | M&L for PCC 1:4:8 type D-2 (using 40mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed. |
| 24 | Supply and fix Double wall Corrugated High Density Polymer Ethyl (HDPE) pipe For laying of Electric cable of size 50mm outer diameter and 38 mm inner Diameterwith IS 14930 (part 2):2001 laid in trenches, wall, floor, pole including bends, sockets and other connected accessories complete all as specified and directed. |
| 25 | Supply and fixing in repairs wall mounted bus -barthree ph,double door 6 way , 415 Volts with 4 nos Aluminium Bus bar 200 Ampincluding MCCB 100 Amp ,25 KA 4 pole =01 No in sheet metal enclosere of 1.6 mm thick MS sheet with powder coat painted including connecting with existing system and cabling network including making good disturbed surfaces complete all as specified and directed. |
| 26 | Supply & fixing, Laying, jointing and testing LTelectric power cablecrossed linked polyethylene ( XLPE)insulated, galvanised steel strip or wire armoured,ISI-7098 Marked, with aluminium conductor multi stranded , heavy duty 1100 Volts grade of size 10 sqmm cross sectional area 4 core complete all as specifiedand directed. |
| 27 | M&L Earthing complete with galvanized steel plate electrode 60cm x 60cm x 6.0mm thick buried directly in ground earth pit not less than 2.25 meter deep below normal ground level with top edge of the plate not less than 1.5m below normal ground level connected to galvanized wire galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washer of galvanized iron or steel all as shown in electrical plate No 3 of SSR Part-I connected to continuous earth wire on pole all as specified and testing on completion, including provision of earth wire protected by 15mm dia GI light grade protection pipe from test point to main board and 20mm GI medium grade watering pipe funnel, PCC earth pit andRCC cover charcoal, salt and GI wire including excavation and earth work etc complete all as directed at site.complete all as specified and directed. |
| 28 | S&F PVC Conduitfor suitable for Cable 10 Sqmm 4 core with accessories for make some AC Connection point complete all as directed. |
| 29 | Supply & fix starter for suitable0.75 Hp to 3 HP motor , 415 Volts AC, 50 Hz, complete with in enclosere with powder coat painted IP-54 ,including connecting with existing system and cabling network including making good disturbed surfaces complete all as specified and directed. |
| 30 | Cutting of existing pipe andposition for insertion of new Tees for branch connections,complete all as specified and directed |
| 31 | M & L for Rotational moulded polyethylene water storage tanks 2000 Ltr capacity(cylindrical vertical with closed top) hoisted and fixed in position complete all as specified and directed |
| 32 | Supply & lay,in trench GI Tubing25 mm medium grade with all fitting completeall as specified and as directed |
| 33 | M&L , Gun metal globe valve 25 mm with iron wheel head heavy duty screwed both ends for iron pipe for union , ISI markedcomplete all as specified & directed |