| 1 | Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth for laying pipes or foundation etc. or for shafts, wells, cesspits, manholes, pier holes etc. n.exc 10sqm on plan and getting out in any type of soil, complete all as specified and directed. |
| 2 | Returning, filling in including spreading, levelling, watering and well ramming in layers n.exc 25cm in any type of soil, complete all as specified and directed. |
| 3 | Removing excavated material (soil) to a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point, complete all as specified and directed. |
| 4 | M&L for rectification of existing defective run lead joints including burning and removing the old defective lead joints and providing new lead joints with all required materials and testing the joints for leakages for the following sizes of CI/DIpipes complete all as specified and directed.(Note: Earth work shall be measured separately) |
| 5 | 80 mm bore |
| 6 | 100 mm bore |
| 7 | 150 mm bore |
| 8 | Supply and replace sluice valve spindle made out of EN-8 steel with check nut made out of brass/bronze material including replacing perished gland packing, rubber gasket, bolts and nuts suitable for the following sizes of sluice valves complete all as specified and directed. :- |
| 9 | 80 mm dia sluice valve |
| 10 | 100 mm dia sluice valve |
| 11 | 150 mm dia sluice valve |
| 12 | S&F in replacementfor Cl sluice valve, non-rising type conforming to IS-14846, suitable for 150 mm bore pipe consisting ofSS spindle as per IS 6603, Cast iron Body, Dome & Wedge as per IS 210,greasy jute type gland packing, fasteners as per IS 1367, Natural rubber gasket, CI manual hand wheeletc. completedouble end flanged and drilled,ofClass PN-1.6 ( ISI marked) including all jointing materials such as rubber gasket insertionsheet nut ,bolts and washers etc. complete all as specified and directed. |
| 13 | All as peritem No.6 here-in-before but size 100 mm dia |
| 14 | All as peritem No.6 here-in-before but size 80 mm dia |
| 15 | M&L for attending break down of pipe line bursting/cracks including excavation in hard/ dense soil with the use of Earthmoving machinery/ labour and taking out oldCI/ GI /MSdefective/ misaligned water pipe line of size 200/150/100/80 mm dia bore carefully after disconnection of joints to a length up to 8 mtr and create bund with excavated earth and dewatering/ bailing out water complete with diesel engine driven pump set and positioning the pipe line after repairs, returning filling and removal of surplus soil/ excavated material with the help of excavator/ proclainer all as directed by Engineer-in-Charge. |
| 16 | NOTE: (a)M/L for LeadJoints/ spares / CI /GI specials will be measured and paid separately.(b)M/L for CI / GI/MS pipe, Specials, lead joints etc. will be measured and paid separately under relevant Schedule Items(c)The rate is deemed to include Cost for tool and plant and transportation required for attending the repair work.(d)Disconnecting / dismantling/ cutting the existing pipe line is included in the quoted rate .(e) The rate is inclusive of earth work complete including returning & refilling in any type of strata complete. (f) The breakdown shall be attended within 4 Hrs. of intimation round the clock and time of restoration shall be maximum of 8 Hours. The additional manpower required to complete the job in quoted rate is deemed to be included in the quoted. |
| 17 | M & L for CI fittinglike tees, bend, sockets ,collars of any typewith rubber gaskets and jointing material complete all as specified for sizes upto 100 mm dia DI pipe line complete all as specified and directed. |
| 18 | Supply, fixing and laying in repair Cost iron flanged pipe Centrifugally, class B confirm to IS 1536-2001 with rubber gasket and jointing material as per standard of following sizes complete in trenches/on pedestals etc all as specified and directed.Note : (Earth work includes excavation, returning & filling and removal, CI fittings will be measured and paid separate where required). |
| 19 | 80 mm bore |
| 20 | 100 mm bore |
| 21 | 150 mm bore |
| 22 | Supply, fixing, testing connecting air release valve of size 80 mm dia with 1 air outlet Kinetic design with isolating valve as per IS 14845 including dismantling of unserviceable Air release valve on100 to 150 mm dia CI/DI pipeline complete all as specified and directed. |
| 23 | Supply and fixing gun metal gate valve with iron wheel head screwed both ends for iron pipe of following size including dismantling old one, complete all as specified and directed. |
| 24 | 15 mm bore |
| 25 | 20 mm bore |
| 26 | 25 mm bore |
| 27 | 40 mm bore |
| 28 | 50 mm bore |
| 29 | Supply and laying in trenches/on roof/ on wall/ steel water tubing galvanized medium grade with all fittings of following sizes, complete all as specified and directed. |
| 30 | 15 mm bore |
| 31 | 20 mm bore |
| 32 | 25 mm bore |
| 33 | 40 mm bore |
| 34 | 50 mm bore |
| 35 | 80 mm bore |
| 36 | Taking up and down old/unserviceable GI tubing with fittings of following size complete all as specified and directed. (Earth work will be measured and paid under respective items of sch \"A\"). |
| 37 | 15 mm bore |
| 38 | 20 mm bore |
| 39 | 25 mm bore |
| 40 | 40 mm bore |
| 41 | 50 mm bore |
| 42 | 80 mm bore |
| 43 | Supply, fixing and laying ductile iron pipe, with jointing materialas per standard complete of class K-7 of 150mm bore sizes complete in trenches/ on pedestals etc complete mortar lining (CML) and outside black bitumen coating etc, complete all as specified and directed. Note: (Earth work including excavation, returning & filling and removal, DI fittings will be measured and paid separately where required). |
| 44 | All as per serial item No. 14 here-in-before but of size 100 mm bore |
| 45 | All as per serial item No. 14 here-in-before but of size 80 mm bore |
| 46 | M&L for carrying out physical, chemical & Bacteriological analysis all as per IS 10500:2012 for Drinking water sample of the Fresh water from Pump Houses at various locations from approved laboratory, complete all as specified and directed.Note : The rate quoted deemed to inclusive of collecting water sample in Sterilized bottle/PVC container & submitting the same for testing. |
| 47 | Repair to GI pipe lines of size 15 to 25 mm bore dia and repair to leaked joints of pipe line complete including replacement of GI fitting i.e. union, nipple & sockets if required including excavation and taking up & down required cutting, threading & refixing in position in trenches, complete all as specified and directed. |
| 48 | All as per serial item No. 16 here-in- before but size 40 to 80 MM bore. |
| 49 | M&L for dismantling of old U/S valve pit and making new of size 120x120x90 Cm ( internal dimensions of the chamber)including and removingthe debrisat a distance not exceeding 50 Mtr and M/L for brick masonry with cement mortar with 1: 6 , 23 cm and flush pointing externally work proceeds in the same mortar complete ( using 30% old bricks & 70% New bricks) complete with the following specifications and as directed by Engr-in-Charge.Note :-(i) 10mm thick plaster internally in CM 1:6.(ii) Flooring 40mm thick in PCC 1:2:4 type B-1 over 75mm thick hard coreofgauge not exc 63mm thick. (iii)Angle ironframe40X40X6mm thick for cover and mild steel 3mm thick cover with locking arrangement, handle and necessary hinges etc., (iv) PCC 1:3:6 type C-2 100mm thick in foundation .(v) Two coat of synthetic enameled paint to cover internally and externally over a paint of Red Oxide primer. |
| 50 | All as per serial item No. 18 here-in-before butof size 100x100x105 cm |
| 51 | All as per serial item No. 18 here-in-before butof size 90x90x105cm |
| 52 | All as per serial item No. 18 here-in-before butof size 60x60x60 cm |
| 53 | Supply and fixing in repair Rubber gasket joint suitable for 100 mm bore cast iron/DI pipes all as specified and directed. |
| 54 | Supply and fixing in repair Rubber gasket joint suitable for 150 mm bore cast iron/DI pipes all as specified and directed. |
| 55 | Supply and fixing in repairRubber gasket joint suitable for 80 mm bore cast iron/DI pipes all as specified and directed. |
| 56 | S&F in repair Cl swing check NRV conforming to IS-5312, suitable for 100 mm bore pipe consisting Cast iron Body, door as per IS 210, Bronze body ring as per IS 318, natural rubber door face, hinge pin SS ASTM A276 type 410, fasteners as per IS 1367, Natural rubber gasket,etc. completedouble end flanged and drilled,ofClass PN-1.6 ( ISI marked) including all jointing materials such as rubber gasket insertionsheet nut ,bolts and washers etc. complete all as specified and directed. |
| 57 | S&F in repair Cl swing check NRV conforming to IS-5312, suitable for 150 mm bore pipe consisting Cast iron Body, door as per IS 210, Bronze body ring as per IS 318, natural rubber door face, hinge pin SS ASTM A276 type 410, fasteners as per IS 1367, Natural rubber gasket,etc. completedouble end flanged and drilled,ofClass PN-1.6 ( ISI marked) including all jointing materials such as rubber gasket insertionsheet nut ,bolts and washers etc. complete all as specified and directed. |
| 58 | Dismantling old defective water meters and M & L for CI water meter Woltman type Magnetic Drive Class-B Flanged end of size 150 mmcomplete all as specified and directed. |
| 59 | Dismantling old defective water meters and M & L for CI water meter Woltman type Magnetic Drive Class-B Flanged end of size 100 mmcomplete all as specified and directed. |
| 60 | Disconnecting the delivery line and providing dummy plate with nut, bolts to avoid water leakages and M&L for taking out vertical turbine pump /submersible pump set of any make of capacity20 HP to 35 HP from the tubewell/borewell carefully complete with column pipe for inspecting the condition of column pipe, pump set &flat submersible cable etc. complete all per site requirement complete all as specified and directed.Note:(i) The cost inclusive of necessary T&P of removing vertical turbine/submersible pump set carefully without any damages to pump, motor, shaft, column pipe and casing. Any damages shall be beared by the Contractor at his own cost. (ii) The rate inclusive of dismantling of motor of Vertical turbine pump set.(iii) The M/L for repairs to pump sets/ column pipe/cable if required & measured and paid separately under relevant Schedule. |
| 61 | Lowering vertical turbine pump /submersible pump set of any make of capacity20 HP to 35HP inside the tubewell/borewell carefully complete with column pipe and other connected parts and including replacement of nut ,bolts, washers, gasket of suitable size all per site requirement and re-connection with delivery line with nut ,bolts, washers, gasket of suitable size allas specified and directed.Note:(i) The cost inclusive of necessary T&P of lowering vertical turbine/submersible pump set carefully without any damages to pump, motor, shaft, column pipe and casing. Any damages shall be beared by the Contractor at his own cost. (ii) The rate inclusive of re-connection of motor of Vertical turbine pump set. |
| 62 | S & F in replacement of oil seal of motor of capacity 20 HP to 35 HP, complete all as specified and directed. |
| 63 | M&L Strip opening of 3 phase AC submersible motor, taking out burnt winding coil complete and re-winding with PVC insulated super quality water proof winding wire including PVC seal (water proof compound) and thrust bearing as per requirement of existing size and make, re-assembling the motor and testing complete of capacity 20 to 35 HP motor. |
| 64 | Taking out worn out bearing/ bush sleeves from the submersible motor of capacity 20 to 35 HP and providing new stainless steel, turning and polishing of bushes complete including checking of alignment complete in all respect all as specified and directed. |
| 65 | S & F in replacement of thrust bearingplate along with disc of motor of capacity 20 HP to 35 HP, complete all as specified and directed. |
| 66 | Dismantling the submersible pumping set bowl assembly/motor of any make for carrying out repair and replacement of worn out parts by strip opening with all parts such as bowl casing, impellers, pump shaft, bushes neck ring etc.and machine work such as welding, turning, re-facing where required and replacing of parts of pump of 4 to 9 stages, size 150mm, of capacity 20 HP to 40 HP capacity complete all as specified and directed.Note: - Spares parts and their fixing shall be paid separately under the respective item of schedule \"A\" |
| 67 | S&F in replacement of pump shaft of stainless steel suitable for submersible pump set up to 9 stages including threading, cutting to required size all as specified and directed. |
| 68 | S & F in replacement of gun metal/ Stainless Steel impellers of suitable size for bowl assembly of submersible pumping set as per site requirement for suction, discharge and intermediate bowls complete all as specified and directed. |
| 69 | S & F in replacement of cast iron casing suction/ discharge/intermediate with studs, all as required at site and directed. |
| 70 | S & F in replacement of shaft seal of rubber all as specified. |
| 71 | S & F in replacement neck ring of bowls suction/discharge/ intermediate all as required at site and directed. |
| 72 | S & F in replacement of gun metal bush of bowls all as required at site and directed. |
| 73 | S & F in replacement of rubber bushes of bowls assembly of suitable, make and model as per existing for suction and discharge bowls all as required at site and directed. |
| 74 | S & F in replacement of shaft coupling with key stainless steel of suitable sizes, type, make and model as per existing, all as required at site and directed. |
| 75 | S & F in replacement of stainless steel middle/distance bush of suitable size all as required at site and directed. |
| 76 | S & F in replacement of stainless steel impeller key all as specified and directed. |
| 77 | S & F in replacement of studs with nuts all as directed. |
| 78 | Supply and fixing in repair of mild steel column pipe coupling 100 mm dia, heavy duty 3.0 Mtr long threaded or flanged all as specified and directed. |
| 79 | Supply and fixing in repair of mild steel column pipe coupling 80 mm dia, heavy duty 3.0 Mtr long threaded or flanged all as specified and directed. |
| 80 | Supply and fixing in repair line shaft bearing retainer of gun metal with rubber bushes for column pipe 150 mm dia all as specified and directed. |
| 81 | Supply and fixing of stainless steel shaft sleeve of size 25 mm to 31 mm dia all as required at site and directed. |
| 82 | Cutting and removing worn out threaded portion of mild steel column pipe heavy duty and re threading the same up to specified length to match with socket of size 150 mm dia. |
| 83 | Cutting and removing worn out threaded potion mild steel/stainless steel line shaft of any dia, length and rethreading the same up to specified length to match with existing coupling all as specified and directed. |
| 84 | S & F in repair new bolts with nuts and washers in places of existing worn out/unserviceable bowl bolts. |
| 85 | Supply and fixing submersible cable 16 Sqmm copper 3 core all as specified and directed by Engr-in-charge. |
| 86 | M&L for chlorination treatment with high stable Calcium based granular disinfectant for water treatment, more stable than Chlorine Gas, and stronger than bleaching powder and sodium Hypochlorite, packing in 45 kg drum complete all as specified and directed by Engr-in-Charge. |
| 87 | S&F in repair chlorination dosing system booster pump of capacity 0.25 HP with suitable coupling asdirected. |
| 88 | S&F in repair chlorination dosing system induction motor single phase 230 volts 0.25 HP capacity all as directed. |
| 89 | Supply and fixing in repair automatic star delta submersiblestarter 3 phase 50 Amp current rating complete all as specified and directed. |
| 90 | S&F in repairs submersible pump controller automatic type in sheet enclosure for maximum motor output 30 HP/22.5 KW with relay max range 28 to 42 Amps suitable for AC -3 duty, 415 V 50 Hz, 3 Phase AC supplywith overload, Single Phasing,Phase imbalance, IP 54 enclosure complete with push buttons etc all as specified and directed. |
| 91 | S&F in repairs submersible pump controller type in sheet enclosure for maximum motor output 50 HP/37.5 KW with suitable size relay for AC -3 duty, 415 V 50 Hz, 3 Phase AC supplywith overload, Single Phasing, Phase reversal, Phase imbalance, IP 54 enclosure complete with Voltmeter & Ammeter, LED indication lamps, push buttons etc complete all as specified and directed. |
| 92 | S&F in repairs submersible pump controller oil immersed type in sheet enclosure for maximum motor output 50 HP/22.5 KW with relay max range 28 to 42 Amps suitable for AC -3 duty, 415 V 50 Hz, 3 Phase AC supplywith overload, Single Phasing,Phase imbalance, auto restart features, IP 54 enclosure complete with push buttons etc complete all as specified and directed. |
| 93 | S&F in repair single phase preventor relaywith timer for auto restart option with protection features against single phasing, phase reversal, phase unbalance etc. complete with control wiring all as directed. |
| 94 | S&F in repair electronic timers suitable for fully automatic star delta starter panel suitable for 240/360/415 V AC supply operation with timer range 3 to 30 Sec, 12 to 120 Sec complete with control wiring all as directed. |
| 95 | S&F in repair Multifunction meter for measuring Volt/ Amp/ frequency meter with inbuilt selector switch class 0.5/1.0 , 230 V AC Aux supply 96x96 Sqmm size suitable for 5A CT. |
| 96 | S&F in repairDigital Ammeter for measuring Amps with inbuilt selector switch class 0.5/1.0 , 230 V AC Aux supply 96x96 Sqmm size suitable for 5A CT all as required at site and directed. |
| 97 | S&F in repairDigital Voltmeter for measuring Voltage with inbuilt selector switch class 0.5/1.0 , 230 V AC Aux supply 96x96 Sqmm size all as required at site and directed. |
| 98 | Material and labour for cleaning of over head water tank of capacity above 30000 Glns upto 75000 Glns at15m to 21 m approx height staging by draining out/bailing out/pumping out the accumulated water at the bottom and removing the complete silt from the sump and depositing and levelling as directed and cleaning the tank with the bleaching powder slurry and wire brush after scrapping the walls and bottom of the tank completelyincluding flushing out inlet/ outlet/ washout pipes/ valves complete without disturbing the water supply to the area including painting the details of sump capacity, date of cleaning and due date of cleaning on the sump wall and applying one coat of white wash to entire sumpinternally. Three Photographs of inside surface of tankof each OH Tanks should be taken before cleaning & after cleaning and submitted to Engineer-in-charge in coloured hard copy complete all as specified and directed. Note:- (i) Rates are to be including charges of hiring T&P.(ii) Contractor shall be responsible for care and safety of person deployed for cleaning to off reservoir. |
| 99 | M&L for preparation and painting the external surface of over head reservoir wire having staging 18 mtr capacity50000 to 75000 glns with two coats of exterior grade weather proof Cement base paint After Priming plastered and other surfaces with alkali resistant priming paint and painted to over head tank, railing and iron ladder ,doors with super synthetic, heat resistant paint complete all as specified and directedincluding all existing writing works with enameled paint complete all as specified and directed. Note:- (i) Rates are to be including charges of hiring T & P.(ii) Contractor shall be responsible for care and safety of person deployed for cleaning to off reservoir.(iii) The paint of incoming and outgoing pipes as per colour coding. |
| 100 | Disconnecting / Removing existing U/S scale type water level indicator and S&F dial type water level indicator suitable for Over Head Storage tank of height 15 m to 21 m staging complete with central movement plate, counter weight, centre dividing wheels, MS/CRCA enclosure, float and connecting control wire system from tank to indicator etc. complete grouted in PCCall as directed including testing and commissioning all as directed. |
| 101 | Note for item No 67 to 69: The rate quoted inclusive of all safety equipments, T&P for carrying out the repair/working on OH tanks and insurance to persons deployed for cleaning the over head tank. Any unforeseen incidents/accidents due to lack of safety norms shall be beared by the Contractor on \" No cost basis\"without any extra claim from department. |
| 102 | Replacement of unserviceable bleaching dosing plant any model any capacity alongwith components, dismantling and segregation of all parts and depositing them and S&F in repair/replacement Adjustable High pressure, power input 230 V, 50 Hz 40 Spm 1/30 fractional horse power, working pressure upto 15 Kg/sq cm& max output 0-30 ltr/hr with mandatory accessories like lead tubing, connecting ferrule, injector check valve, etc. Accessories must include following:- Preparation tank of min capacity 170 ltrs. FRP dosing tank dia 650X net height 375 + conical 300mm, gross height with stand 1000mm consisting of water inlet line, outlet with Y strainer. Drain, overflow, conical bottom for sludge deposition, pot hole cover, level gauge, Agitator 120 watt 900 rpmsingle phase flange mounted motor with plastic shaft and impeller and service tank of net capacity 100 ltrs of FRP dosing tank consisting of water inlet line, dosing pump inlet arrangement, drain, overflow level gauge, inspection port, etc along with all the other accessories as per site requirement complete all as specified and directed by Engr-in-Charge. |
| 103 | Material and labour for rewinding of existing unsv 3 Phase, 3 HP/ 2.25 KW , 50 Hz, 2820 RPM induction motor any make with super enameled copper winding wire ofgauge as per existingincluding cutting and getting out old US winding, sleeve work, varnishing with E class insulation varnish , threadingand making all electric connections including taking out and refixing at site complete all as specified and directed. |
| 104 | Material and labour for rewinding of existing unsv 3 Phase, 5 HP/ 3.75 KW , 50 Hz, 2800 RPM induction motor any make with super enameled copper winding wire ofgauge as per existingincluding cutting and getting out old US winding, sleeve work, varnishing with E class insulation varnish , threadingand making all electric connections including taking out and refixing at site all as specified and directed. |
| 105 | S&F in replacement aviationLEDlightdie cast aluminiumalloyhousing redcolouredpolycarbonatedome& accessories including LED lamp complete, commissioning & testing complete all as specified and directed. |
| 106 | M&L for repair/ servicing to over head water level indicator gauge complete with replacement of float valve steel 200mm, Pully as per site requirement, steel pulling wire, fixing clumps etc andapplying two coats ofsuper enameled black paint over a coat of red oxide paint on whole scale and rewriting of existing marking with super enameled white paint to scale of overhead tank /sumps etc complete all as specified and directed.Note-: (i) Rates are to be including charges of hiring T & P.(ii) Contractor shall be responsible for care and safety of person deployed. |
| 107 | M&L for repair to mild steel ladders, grill, covers installed on overhead tank / sumps by replacing of defective /corroded pieces including cutting ,welding & painting with two coat high quality synthetic enamelpainted black colour to match existing surface complete all as specified and directed. |
| 108 | Supply only water testing kit (Residual chlorine reagent-1) including test tube, dropper etc complete all as specified and directed by Engr- in-Charge |
| 109 | Supply only water testing solution (Residual chlorine reagent-1) all as specified and directed by Engr- in-Charge |
| 110 | S&F in replacement 4 Pole MCCB, 415 V, Adjustable type with breaking capacity 36 KA, 400 A rated, complete all as specified and directed. |
| 111 | S&F in replacement 4 Pole MCCB, 415 V, Adjustable type with breaking capacity 36 KA, 250 A rated, complete all as specified and directed. |
| 112 | S&F in replacement 4 Pole MCCB, 415 V, Adjustable type with breaking capacity 36 KA, 200 A rated, complete all as specified and directed. |
| 113 | S&F in replacement 4 Pole MCCB, 415 V, Adjustable type with breaking capacity 36 KA, 160 A rated, complete all as specified and directed. |
| 114 | S&F in replacement 4 Pole MCCB, 415 V, Adjustable type with breaking capacity 50 KA, 630 A rated, complete all as specified and directed. |
| 115 | Supply and fix in replacement of pressure gauge 100 mm dia of water pipe line suitable for pressure rating 0-100 Kg/cm2 complete all as specified and directed. |
| 116 | S&F in repair High density polyethylene pipes (HDPE) of pressure rating 6 kgf/cm2 laid in trenches/ on floor/ walls etc complete all as specified and directed including dismantling old defective pipe lines. Note: The rate quoted deemed to be inclusive of all fittings necessary for fixing the pipe to GI pipes wherever required. |
| 117 | 20 mm bore |
| 118 | 25 mm bore |
| 119 | 40 mm bore |
| 120 | 50 mm bore |
| 121 | Note for item No.1 to 85: The work involves of various areas of AGE E/M (S) Pathankot. TheContractor shall depute manpower on daily basisattending and rectifying the job in time. If any breakdowns/ complaints simultaneously occurred in any areas shall be attended simultaneously by deputing additional manpower/ T&P for rectification of defects. The rate quoted deemed to be included for the same. Recovery for non attending of any type rectification/ complaint/ breakdowns shall be at the rate of Rs 2500 per day irrespective nature of complaint/defect. |
| 122 | Note: (i) In case the tenderer quotes different rates for similar item then lowest rate shall only be applicable for payment and contractor shall not have any claim on this account.(ii) The Schedule of Credit amount shall be deducted from the total of this schedule (BoQ) to arrive at Contract Sum. |