}

Annual Plan-Gp Alangad-Revised Estimate --Supply And Providing 40 Kva Gen Set To The Phc Karinganthuruth.-General Electrical Work, alangad-Kerala

Local Bodies has published Annual Plan-Gp Alangad-Revised Estimate --Supply And Providing 40 Kva Gen Set To The Phc Karinganthuruth.-General Electrical Work. Submission Date for this Tender is 15-10-2024. Tanks and Cylinders Tenders in alangad Kerala. Bidders can get complete Tender details and download the document.




Tender Notice

45385193
Annual Plan-Gp Alangad-Revised Estimate --Supply And Providing 40 Kva Gen Set To The Phc Karinganthuruth.-General Electrical Work
Open Tender
Indian
Kerala
Alangad
15-10-2024

Tender Documents

Tender Details

Annual Plan-GP Alangad-Revised Estimate --Supply and providing 40 KVA Gen set to the PHC Karinganthuruth.-General Electrical Work , Electrical , 14.1:Excavation For Foundation In Soft Soil Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 Metres. , 14.3:Filling Available Excavated Earth (Excluding Rock) In Trenches, Sides Of Foundations Etc. In Layers Not Exceeding 20Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50 Metres. , 14.7:Providing And Laying In Position Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size) In Foundation Of Pump, Dg Set Etc Including Form Work Etc As Required. , 14.12:Providing 15Mm Thick Cement Plaster Of Mix 1:4(1 Cement: 4 Fine Sand) At All Levels , Od83665/2024-2025:Supply Installation Testing And Commissioning And Trail Run Of40kva Three Phase 440 V, 1500 Rpm , 0.8 Power Factor, 50 Hz Canopised Diesel Comprising Generation Unit Ofashok Leyland Modelh4g4de40 - 3 Cylinderdiesel Engine Cpcb4+ Developing 52 Bhp At 1500 Rpm Coupledwithleroy Somers/ Crompton40 Kva Alternator 415 Volts- 3 Phase, Complete With Standard Accessories Mounted On A Channel Iron Base Frame, Fuel Tank, Standardcontrol Paneland Battery,Battery Leads With Battery Charger Etcincludingsupply And Fitting With Cpcb Approvedacoustic Enclosure Complete With Stdcontrol Panel, Sound Level-75 Db @ One Metre From Enclosure Surface In Free Field Condition As Per Iso 8528 And Maintain A Warranty Of 24 Months Or 5000 Hrs From The Date Of Commissioning Including Engine Critical Parts Warranty Etc As As Required. , Od83670/2024-2025: Supply, Conveying & Fixing 65 Mm Dia Heavy Ms Pipe With Suitable Heavymsspecials Such As Bend, Reducer Etc As Silencer Extensionpipe Including Cutting In To Required Length,And Supply And Providing Ms Flanges Having 12 Mm Thickness As Required, Including Conveyance Charges And Paintingthe Pipe Etc , 90.12.7.1:Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armoured Aluminium Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages , Colour Washing Etc. As Required.2 Core 4 Sq Mm With Factory Made Clamp , 90.12.5.43:Supply & Laying Of One Number Pvc Insulated And Pvc Sheathed Armoured Aluminium Power Cable Of 1.1Kv Grade Of The Following Sizes In The Existing Rcc/ Hume / Stone Ware/ Gi/ Dwc Pipe As Required.4 Core 35 Sq Mm , 90.12.7.43:Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armoured Aluminium Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages , Colour Washing Etc. As Required.4 Core 35 Sq Mm With Factory Made Clamp , 9.1.1:Supplying And Making End Termination With Brass Compression Gland And Aluminium Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required.2 X 6 Sq. Mm (19Mm) , 9.1.35:Supplying And Making End Termination With Brass Compression Gland And Aluminium Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required.4 X 35 Sq. Mm (32Mm) , Od84197/2024-2025:Supply And Providing Copper Earthing Clip 12Mm Widex1mm Thick Suitable For 4 Sq Mm To 16 Sq Mm Cable Gland Connection Etc In Correct Alignment. , Od84196/2024-2025:Supplying And Providing Earth Clamps For Siemens/ Tropodur Type Cable Glands Of Suitable Length And Other Dimensions Noted Along With Eachsize Of Glands For The Following Sizes Of Cables As Required.25 To 95 Sq Mm With 20Mm Wide X 1.20 Mm Thick Clip , 90.12.9.2:Supplying, Laying And Jointing Of The Following Sizes Of Double Wall Corrugated (Dwc) Pipes Made Out Of Hdpe Conforming To Is 14930 Part Ii For Mechanical Protection To Underground Power Cables With All Required Accessories In Ground In The Existing Trench50/38 Mm Or Nearest Size , Od84198/2024-2025:Supply And Fitting 100A 4P Changeover Switch On Open Exicution L&T Or Similar Make Cat No Co22000a To The Proposed Panel Board As Required Connection Etc , Od84199/2024-2025:Supply ,Conveyance And Fabrication Of Ms. Clamp / Bracket Using Ms Angle / Flat/Rode And Bend/ Weld In Shape And Fitting Charges Of The Same In Required Position Using Bolts And Nuts Including Painting As Required . , 5.4:Earthing With G.I. Earth Plate 600 Mm X 600 Mm X 6 Mm Thick Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Metre Long Etc. With Charcoal/ Coke And Salt As Required. , 90.12.10.2:Supply & Laying Of Dwc Pipe In Ordinary Soil 0.75M Below Ground Level Including Excavation50/38 Mm Or Nearest Size , 90.16.2.1:Supply And Laying Of The Following Sizes Of B Class Gipipe Laid 0.6 M Below Ground Level Including Excavating Trench Of Suitable Size And Refilling Etc, As Required.15.Mm Dia. G.I Pipe ( Medium Class) , 90.16.1.2:Supply And Drawing Bare Earthing Conductors Of The Following Sizes Along With Wiring/ Cables And Giving Connection As Required2.65 Mm Copper Conductor (12 Swg) , 90.16.1.5:Supply And Drawing Bare Earthing Conductors Of The Following Sizes Along With Wiring/ Cables And Giving Connection As Required4.75 Mm Copper Conductor (6 Swg) , 90.16.3.8:Supply And Clamping The Following Size Of Strips On Surface Of Wall/ Parapet/ Existing Cable Tray Using Clamps Fabricated From 20 X 3 Mm Gi Flat Duly Painted Or Heavy Duty Gi Spacer Saddles Spacing Of Clamps Not Exceeding 1 M, Making Good The Damages, Colour Washing Etc. As Required ( For Horizontal Run)20 X 3 Mm Copper Strip , 90.16.5.2:Supply Of Superior Quality Copper Earth Socket For The Following Size Of Earth Conductor Including Crimping Etc. As Required.2.65 Mm (12 Swg) , 90.16.5.5:Supply Of Superior Quality Copper Earth Socket For The Following Size Of Earth Conductor Including Crimping Etc. As Required.4.75 Mm (6 Swg) , Od84208/2024-2025:S&F 12X3 Mm Brass Bolt Nut Washers Etc As Required , Od84210/2024-2025:S&F 25X6mm Brass Bolt Washer Etc As Required , Od84212/2024-2025:Supply And Providing 5Kg Dry Chemical Powder Type Fire Extinguisher With Hose And Clamp And Fix It To The Wall As Required , Od84213/2024-2025:Supply And Providing 9 Ltr Capacity Gi Bucket Painted With Post Office Red And Write Letter With Paint As Required And Filling Fine Sand In Required Quantity In Position Using Coch Screw Etc , Od84214/2024-2025:Supply And Providing First Aid Chart Duly Framed And Placed In Required Place For Clear Vision , Od84219/2024-2025:Charges For Preparing Scheme For Submitting And Obtaining Sanction For The Scheme From The Electrical Inspectorate Including Statutory Fees Reimbursed Against The Receipt From The Electrical Inspectorate.( Actual Amount Paid On Production Of Original Invoice/Bill ) , 1.27.2:Supplying And Fixing Following Size/ Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc As Required.3 Module (100Mmx75mm) , 1.24.3:Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.15/16 Amp Switch , 1.24.5:Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.6 Pin 15/16 Amp Socket Outlet , 2.15.3:Supplying And Fixing Following Rating, Four Pole, (Three Phase And Neutral), 415 Volts, Residual Current Circuit Breaker (Rccb), Having A Sensitivity Current Upto 300 Milliamperes In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.63 Amps

Key Value

Document Fees
INR 1970 /-
EMD
INR 10800.0 /-
Tender Value
INR 10.80 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Notice 0 KB
Click here to download tender document Tender Document 0 KB
Click here to download tender document Tender Document 0 KB
Click here to download tender document Tender Document 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail