}

Tender For Supply And Fixing Of Electric Item At Mlb Govt Para Medical Traning College Jhansi, E-Tender For Repair And Supply Of Material For 11 Kv Sub-Station, Electrical Panels,Fans, Dg Set And Equipmentsetc. At Mlb Rajkiya Para Medical Training College, jhansi-Uttar Pradesh

Boards / Undertakings / PSU has published Tender For Supply And Fixing Of Electric Item At Mlb Govt Para Medical Traning College Jhansi, E-Tender For Repair And Supply Of Material For 11 Kv Sub-Station, Electrical Panels,Fans, Dg Set And Equipmentsetc. At Mlb Rajkiya Para Medical Training College. Submission Date for this Tender is 17-10-2024. Clamps Tenders in jhansi Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

45365663
Corrigendum : Tender For Supply And Fixing Of Electric Item At Mlb Govt Para Medical Traning College Jhansi, E-Tender For Repair And Supply Of Material For 11 Kv Sub-Station, Electrical Panels,Fans, Dg Set And Equipmentsetc. At Mlb Rajkiya Para Medical Training College
Open Tender
Indian
Uttar Pradesh
Jhansi
17-10-2024

Tender Details

Tender For Supply And Fixing Of Electric Item At Mlb Govt Para Medical Traning College Jhansi, E-Tender for Repair and supply of material for 11 KV Sub-Station, electrical panels,Fans, DG Set and equipmentsetc. at MLB Rajkiya Para Medical Training College, Jhansi (UP) Sl. No. Item Description 1 Overhauling of 11KV, 350 MVA 630/Amp Indoor Type vacuum circuit breaker complete with Relay & panel accessories. With auxiliary equipments their satisfactory operation. Digital Amp & Volt Meter, Indicator lamp Dig. And Other Standard accessories etc.(Make- Areva) a.Incomer-VCB 630Amp .18.4 KA, CTR400/200/5-521KA 2 b. Outgoing- VCB 630Amp. 18.4 KA, CTR200/100/5-521KA 3 1250 KVA Transformer repairing &binding& installation (All Requirement) 4 630 KVA Transformer repairing &binding& installation (All Requirement) 5 500 KVA Transformer repairing &binding& installation (All Requirement) 6 Complete Maintenance 1250 KVA Transformer (Items that need to be checked yearly) a) Oil in the transformer (this time check the acidity resistivity, tan delta and sludge. It may need to be filtered or replaced entirely) 7 b) Check the Buchholz relay function completely. 8 c) Oil-filled condenser bushing 9 d) Gasket joints (may need to be tightened to avoid uneven pressure) 10 e) Check the transformer marshalling box 11 f) Relays alarm and other circuits 12 g) Transformer body clear& Paintwork 13 h) Transformer Earthing test 14 i) Transformer insulation resistance test 15 j) All power& control terminal tightness and overheating check 16 Complete Maintenance 630 KVA Transformer (Items that need to be checked yearly) 17 a) Oil in the transformer (this time check the acidity resistivity, tan delta and sludge. It may need to be filtered or replaced entirely) 18 b) Check the Buchholz relay function completely. 19 c) Oil-filled condenser bushing 20 d) Gasket joints (may need to be tightened to avoid uneven pressure) 21 e) Check the transformer marshalling box. 22 f) Relays alarm and other circuits 23 g) Transformer body clear& Paintwork. 24 h) Transformer Earthing test. 25 i) Transformer insulation resistance test. 26 j) All power& control terminal tightness and overheating check 27 Complete Maintenance 500 KVA Transformer (Items that need to be checked yearly) a) Oil in the transformer (this time check the acidity resistivity, tan delta and sludge. It may need to be filtered or replaced entirely) 28 b) Check the Buchholz relay function completely. 29 c) Oil-filled condenser bushing 30 d) Gasket joints (may need to be tightened to avoid uneven pressure) 31 e) Check the transformer marshalling box 32 f) Relays alarm and other circuits 33 g) Transformer body clear& Paintwork 34 h) Transformer earthing test. 35 i) Transformer insulation resistance test. 36 j) All power& control terminal tightness and overheating check 37 Carriage of transformer in Para medical training college campus with loading, unloading T&PLabor complete 38 Transformer oil fresh 39 Repairing, Overhauling of 415 V, 4P A free standing floor mounted main panel for A.C. ( make -L&T) INCOMER:2000 A, 55KA 4P,MDO ACB 40 INCOMER:1000 A, 55KA 4P,MDO ACB 41 INCOMER: 800 A, 55KA 4P,MDO ACB 42 Repairing, Overhauling of 415 V, 4P A free standing floor mounted main panel for A.C. INCOMER:1000 A, 50KA 4P 415VACB (MODEL NOAH-10D-CS IEC 60947-2) 43 S/Fof 630 A, 50KA 4P MCCB (Molded Case Circuit Breaker) ( make -L&T) 44 S/Fof 400 A, 50KA 4P MCCB (Molded Case Circuit Breaker) ( make -L&T) 45 S/Fof 250 A, 50KA 4P MCCB (Molded Case Circuit Breaker) ( make -L&T) 46 Supply And fixing of ACB 3 Phase 4-pole 2000A 415 V Cat-B (L&T Make) CN-CS 2000 S1 Amp fixed type manually operated 47 Supply And fixing of ACB 3 Phase 4-pole 1000A 415 V Cat-B (L&T Make) CN-CS 2000 S1 Amp fixed type manually operated 48 Supply And fixing of ACB 3 Phase 4-pole 800A 415 V Cat-B (L&T Make) CN-CS 2000 S1 Amp fixed type manually operated 49 Making of foundation and electric pole with cement, concrete and sand 1:3:6 including around the pole and filling properly complete 50 Charges for one time repair/ maintenance & painting of all electrical distribution panels and all feeder pillar in the Para medical campus. (indoor/outdoor) 51 S/F ofGenerator Battery 180 AH 12 volts .( Lead acid battery) 52 S/F of Battery 150 AH 12 volts. .( Lead acid battery) 53 Supply& Boring of copper plate 600 x 600 x 3mm, vertically for earthing with its top at least 3 mtrs. Below ground level complete with 20mm dia G.I. pipe and funnel for watering and one earthing lead of one no.32x6mm Cu. Stip upto glalso including 30sqcm C.I. frame charcoal/coke and salt at least 150mm thiock alround etc. as per direction of Engg-in –charge complete in all respects. 54 Supply& boring of G.I plate 600 x 600 x 3mm, vertically for earthing with its top at least 3 mtrs. Below ground level complete with 20mm dia G.I. pipe and funnel for watering and one earthing lead of one no.32x6mm Cu. Stip upto glalso including 30sqcm C.I. frame charcoal/coke and salt at least 150mm thiock alround etc. as per direction of Engg-in –charge complete in all respects 55 S/F of Cu. Strip size 50 x 6 mm size for earthing 56 S/F of G.I strip 32 x6 mm size earthing 57 S/F of 11 KVA Grade XLPE cable box outdoor type 185sqmm x 3 core complete 58 S/F of 11 KVA Grade XLPE cable box indoor type 185sq.mm x 3 core complete 59 S/F of Al. conuctor XLPE armoured cables 11000V grade at a depth of 700 mm below ground level over a cushion of 75 mm thick sand allaround and protection with burnt bricks on sides & on top .The armourising of the cable shall be properly connected with the earth conductor by clamps etc. of following sizes:(HT) • 120 sq.mm x 3 core 60 • 185 sq.mm x 3core 61 Painting work of sub –station Transformers,shutter, DG set ,HT/LT panel, feeder pillar ,transformer,transformer shade etc 62 S&F of UPS with battery 1 KVA 63 2 KVA 64 5.5 KVA 65 10KVA 66 12.5 KVA 67 15 KVA 68 Supply and fixing 120 watts LED Flood Lights Fittings Street Light (High power LED Flood Light With Pressure Die Cast Aluminum Housing.(OSRAM, PHILIPS,NICHIA,CREE,EVERLIGHT,TOSHIBA nichia or equivalent 69 Supply& fixing of 2x2 Panel LED celling Lights (Day cool Lights) 42 Watts. Square shape 70 Supply& fixing of 2x2 Panel LED surface Lights (Day cool Lights) 42 Watts. Square shape 71 Supply& fixing of 1x1 Panel LEDcelling Lights ( Day cool Lights) 36 Watts. Square shape 72 Supply& fixing of 1x1 Panel LED surface Lights ( Day cool Lights) 36 Watts.Circle shape 73 Supply 20 to 24 watts LED Tube Lights (syska, Philips, Havells, Suraya, Bajaj) 74 Supply& fixingof 70 to 100 watts LED Street for Lights. (Syska ,Havells, Matador) 75 Supply meter (single phase digital meter 5-30amp) 76 Supply meter (three phase digital meter 10-40 amp) 77 S/F of Fan regulator .Make Legrand 78 Supply Modular Switch 5/6 Amp Make Legrand 79 Supply Modular Switch 15/16 Amp Make Legrand 80 Supply Modular Socket 5/6 Amp Make Legrand 81 Supply Modular Socket 15/16 Amp Make Legrand 82 Supply 3way Modular Plate Make Legrand 83 Supply 6 way Modular plate Make Legrand 84 Supply 8 way Modular plate Make Legrand 85 Supply& fixingof Exhaust fan• 18 Inch 450 mm 86 • 12 Inch 300 mm 87 Supply& fixing 1HP Submersible pump Single phase (make Kirloskar, Crompton) 88 Supply& fixing 1.5 HP Submersible pump Single phase (make Kirloskar, Crompton) 89 Supply& fixing 2 HP Submersible pump Single phase (make Kirloskar, Crompton) 90 Supply& fixing 5 HP Submersible pump 3 phase (make Kirloskar, Crompton) 91 Supply& fixing 10 HP Submersible pump 3 phase (make Kirloskar, Crompton) 92 1HP Submersible pump Single phase binding & Repairing. 93 1.5 HP Submersible pump Single phase binding & Repairing 94 5 HP Submersible pump 3 phase binding & Repairing 95 10 HP Submersible pump 3 phase binding & Repairing 96 Repairing & servicing of 1HP Submersible Starter Single phase 97 Repairing & servicing of 1.5HP Submersible Starter Single phase 98 Repairing & servicing of 2HP Submersible Starter Single phase 99 Repairing & servicing of 5HP Submersible Starter 3phase 100 Repairing & servicing of 10HP Submersible Starter 3 phase 101 Supply and laying 75mm dia GI pipe for laying in of road cutting crossing 102 Supply and fixingof 30 Meter High mask LED Light Pure wight,200 watts 103 Supply and fixingof 30 Meter High mask contactor63 AMP 104 32 AMP 105 S/F OF UPS BATTERY 12VOLTS/7AH 106 S/F ofLT cable joint kit • 25 sq.mm X4 core 107 • 35 sq.mm X4 core 108 • 50 sq.mm X4 core 109 • 70 sq.mm X4 core 110 • 95 sq.mm X4 core 111 • 120 sq.mm X4 core 112 • 150 sq.mm X4 core 113 • 185 sq.mm X4 core 114 • 240 sq.mm X4 core 115 • 300 sq.mm X4 core 116 • 400 sq.mm X4 core 117 Lkhfyax QSu dh dEiyhV fjokbfUMx dk dk;Z lqij buSfeyaM dkWij ok;j vkbZ0,l0vkbZ ekdZ ds }kjk vk;fyax ,oa xzhflax lfgrA 1- 48** iqjkus ia[ks 118 2- 56** iqjkus ia[ks 119 lhfyax QSu ds cq”k cnyus dk dk;Z vk;fyax ,oa xzhfalax lfgrA 1- 48** iqjkus ia[ks 120 2- 56** iqjkus ia[ks 121 lhfyax QSSu ds cq”k cnyus dk dk;Z vk;fyax ,oa xzhflax lfgr 122 Lkhfyax QSu dh vk;y ,oa xzhflax dk dk;ZA 123 Lkhfyax QSu ds dUMsUlj cnyus dk dk;ZA 124 ,XtkWLV QSu dhdEiyhV fjokbfUMx dk dk;Z lqij buSfeyaM dkWij ok;j vkbZ0,l0vkbZ ekdZ ds }kjk vk;fyax ,oa xzhflax lfgrA1&18** 125 2&20** 126 3&24** 127 ,XtkWLV QSu dh ckWyfo;fjax cnyus dk dk;Zaaa A 1&18** 128 2&20** 129 3&24** 130 ,XtkWLV QSu ds dUMsUlj cnyus dk dk;ZA 1&18** 131 2&20** 132 3&24** 133 ,XtkWLV QSSu ds cq”k cnyus dk dk;ZA 1&18** 134 2&20** 135 3&24** 136 dkWEisDVksa rFkk vksoj gsM “ksM ds iksyks dks isUV djkus dk dk;ZA 137 dkWEisDVks rFkk QhMj fiyjksa dh lfoZflax dk dk;ZA 138 dkWEisDVksa rFkk QhMj fiyjksa ds vklikl dh ?kkl dkVkus bR;kfn dk;ZA

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 10-10-2024 Date Extand Date 17-10-2024

Key Value

Document Fees
INR 2000 /-
EMD
INR 100000.0 /-
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail