}

Tender For Provision Of Certain Lbw, Rw And Mw Works At Lgj Mil Stn, Ganganagar-Rajasthan

Statutory Bodies & Commissions/Committees has published Tender For Provision Of Certain Lbw, Rw And Mw Works At Lgj Mil Stn. Submission Date for this Tender is 07-10-2024. Excavation Work Tenders in Ganganagar Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

45361132
Tender For Provision Of Certain Lbw, Rw And Mw Works At Lgj Mil Stn
Open Tender
Indian
Rajasthan
Ganganagar
07-10-2024

Tender Documents

Tender Details

Tender For Provision Of Certain Lbw, Rw And Mw Works At Lgj Mil Stn; 1 Excavation in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundations, shafts, wells, cesspits, manholes, laying pipe line, laying of cables or fixing poles and stays and struts etc. not exceeding 10 Sqm on plan and not exceeding 1.5 metre in depth and getting out in soft/loose soil complete all as specified and as directed by Engineer-in-charge. 2 Add to Ser item 01for each additional 1.5m or part thereof in depth beyond the first 1.5 m complete all as specified and as directed by Engineer-in-charge. 3 Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning soft soil, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm complete all as specified and directed. 4 Material and labour for PCC (1:4:8) type D2 using 40mm graded stone aggregate as in foundation filling & mass concrete complete all as specified and as directed by Engineer-in-charge. 5 Material and labour for 100 mm thick PCC (1:4:8) type D2 using 40mm graded stone aggregate as in sub bass below floor complete all as specified and as directed by Engineer-in-charge. 6 Material and labour for cement concrete 1:2:4type C-2 using 40mm graded stone aggregate as in foundation filling & mass concrete Post holes/Poles/struts/stay etccomplete all as specified and as directed by Engineer-in-charge. 7 Material and labour for brick work with Fly Ash bricks straight or curved on plan exc. 6 metre mean radius built in cement mortar (1:6) complete all as specified and as directed by Engineer-in-charge. 8 M&L fly ash brick work with sub class B brick half thick brick straight or curved on plan exc 6m mean radius in CM 1:4 complete all complete and as specifed and directed. 9 M&L for 40mm thick damp proof course in cement concrete 1:2:4, type B-0, 12.5 mm graded stone aggregateto horizontal or vertical surfaces including necessary formwork complete all as specfied and directed by Engr-in-Charge. 10 M&L for reinforced cement concrete type B1 1:2:4 using 20mm graded stone aggregate inlintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, copings, bed plates,and the like including weathering, slightly rounded or chamfered angles and throating,incl formwork all as specified & directed.Note :- Reinforcement and form work shall be measured and paid for separately under appropriate item of this schedule. 11 M & L for Formwork to fair finished surfaces soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified & directed by Engineer-in- charge. 12 M&L for reinforced cement concrete (design mix) M-25 using 20mm graded stone aggregrate in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like; all as specified and directed.Note : Reinforcement shall be measured and paid seperately. 13 S&F for TMT bars (Fe-500D) 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips all as specified and directed. 14 S&F for TMT bars (Fe-500D) 5 mm dia over upto including 10 mm dia in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips all as specified and directed. 15 Returning filling in incl spreading, levelling watering and well ramming in layer n.exc 25cm thick complete all as specified and directed. 16 Removing surplus soil to a distance n. exc 50 m and depositing where directed at level n. exc 1.5 m above the starting point complete all as specified and directed by Engr-in-Charge 17 M&L for sand filling in floors or in foundations including watering and consolidation all specified and directed 18 M&L sand cushioning with dry and clean locally available sand for under ground cable 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of cable complete all as specified.(Note : Punned thickness shall be considered for payment purpose) 19 M&L for broken stone hardcore of gauge n exc. 63mm, deposited, spread and levelled in layers n exc.15cm thick,watered and rammed to a true surface complete all as specified and directed by Engineer-in-Charge 20 Material and labour for Cement concrete (1:4:8) type D2 using 40mm graded stone aggregate as in sub base complete all as specified and as directed by Engineer-in-charge. 21 Material and labour for 25 mm thick Cement concrete (1:2:4) type B-0 using 12.5 mm graded stone aggregate as in floor or laid under floor etc complete all as specified and as directed by Engineer-in-charge. 22 M&L for joint free non skid ceramic coloured tiles 7 to 8 mm thick (square/ rectengular) area of each tile exc 0.06 Sqm but not exc 0.11Sqm in floor over and including 15 mm thick screed bedding in cement mortar 1:6, set and jointed in neat cement slurry and pointed in coloured cement to match the floor all as specified and directed. 23 M&L joint free glazed ceramic coloured tiles 350 x 250 x 7mm /450 x 350 x 7 mm thick on vertical surfaces as in skirting, dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile laid over and including 10mm thick backing coat in cement mortar (1:4) including necessary cutting as per site requirement complete all as specified and directed by Engineer-in-Charge. 24 M&L for 20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite overand including 20 mm thick screed bed in CM 1:6 completeall as specified and directed. 25 M&L Machined pressed precast concrete interlocking paver block glossy with grey cementand pigment, any shape and size confirming to IS 15658-2006 of 80mm thickness M-35 grade with over sand cushion all as specified and directed.Note: sand filling paid seperately. 26 M & L for size 1.8 m dia x 3.00 m effective depth of soakage well excavation in any type of soil, foundation in PCC 1:3:6, wall of honey combed mansory, with top ring of M-25 concrete including intercepting chamber and screen chamber made of brick mansonry in CM, RCC cover slab in M-25, SFRC cover inter connection pipe of RCC/DWC complete filled with brick bats all as specified and directed (Ref Drg No BTD-804) 27 M&L for 75 mm thick PCC 1:3:6 type C-2 using 40 mm graded mechanically crushed stone aggregate as in plinth protection finished even and smooth without using extra cement with & including 10 mm wide, 30 mm deep joints at the rate of 3.00 mtr centre to centre and at every turning & filling the joints with bitumen & sand mixture complete all as directed. 28 S&F Roof trusses (framed) , trussed , purlines, crane gantries, rails and fastening and heavy bracket framing (Beam, tee, angle, channel or Flat section) including distance pieces , cleats etc Fe-290 (Gde E-165) complete all as specified and directed by Engr-in-charge. 29 M&L rendering 10mm thick cement plaster on brick walls or concrete, surface in cm 1:6on wall and surface to be finished even smooth without using extra cement complete all as specified & directed 30 M&L rendering 10mm thick cement plaster on brick walls or concrete, surface in cm 1:4on wall and surface to be finished even smooth without using extra cement complete all as specified & directed 31 M&L for rendering 15mm thick on brickwork or concrete surfaces in cement mortar 1:4 on wall and finished fair even and smooth with water proofing compound without using extra cemnt all as specified and directed. (WPC shall be measured separatly as supply only) 32 M&L for rendering 15mm thick on roof surfacein cement mortar 1:3finished fair even and smooth with water proofing compound without using extra cemnt all as specified and directed. (WPC shall be measured separatly as supply only) 33 M & L rendering 5 mm thick in cement mortar (1:3) on fair faces of concrete surfacesof ceiling finished fair and even without using extra cement complete all as specified & directed by Engr-in-charge. 34 Supply onlyliquid water proofing compound complete all as specified and directed by Engr-in-charge. 35 Material and labour for preparing newly plastered or pointed surface of wall by sand papering or by any other mean and after preparing the surfaces applying three coats of white wash complete all as specified & directed by Engineer-in- charge 36 Material and labour for preparation of new plastered or pointed surface of walls/pillars /cornices by sand papering or by any other mean and after preparing the surfaces applying two coats of cement base paint as approved tint/colour complete all as specified and as directed by Engineer-in-Charge. 37 Material and labour for preparing newly plastered or pointed surface of ceiling by sand papering or by any other mean and after preparing the surfaces applying three coats of white wash complete all as specified & directed by Engineer-in- charge 38 S&F steel ventilator with top hung shutter incl hinges, handle, steel peg stay complete all as specified and directed by Engineer-in-Charge 39 M&L for preparation of new steel surfaces of any description over 10cm width or girth and applying a coat of red oxide zinc chrome primer andtwo coats of synthetic enamel paint over a coat of primerincluding preparation of surface complete all as specified. 40 Supply & fixing, 4mm thick sheet glass ordinary quality and glazing with oil putty in squares not exceeding0.5 Sqm in each pane complete all as specified & directed by Engineer-in- charge. 41 S & F 4.8 mm thick sheet glass, ordinary quality and glazing with aluminium snap beading of any size of glass in each pane allas specified and directed. 42 S & F 3 mm thickfigured glass, pin head secured with oil putty in squares n exc 0.5 sq. m in each pane complete all as specified and directed. 43 Supply and fixing of Fibre glass Reinforced plastic (FRP)door frame of required colour of cross-section 90mm x 45mm having single ribate of 32mm x 15mm to recieve shutter of 30mm thick includinglaminated door frame moulded with fire retardant grade unsaturated polyster resin and chopped strand mat(CSM) also door frame laminated shall be 2mm thick and shall be filled with suitable wooden block of 2nd class hard wood, frame shall be covered with fibre glass from all sides. MS stay flat iron 25mm x 3mm shall be provided at the bottom to steady the frame complete all as specifiedand as directed by Engineer-in- charge. 44 Supply and fixing of 30 mm thick glass fibre reinforced plastic (FRP) paneled door shutter conferming to IS:14856-2000 of required colour andmade with fire retardant grade unsaturated polyster resin,moulded to 3mm thick FRP laminated for forming hollow rails and style with suitable second class hardwood timber block inside at required places for fixing of fittings,cast molithically with 5mm thick FRP laminated for panels including fixing to frames,complete all as specified and as directed by Engineer-in- charge. 45 S&F for 100 mm long butt hinges, extruded aluminium alloy with galvanised mild steel hings pin, anosied and fixed type B-21 complete all specified and directed. 46 S&F for 100 mm long butt hinges, extruded brass, mild steel hings pin,bright polished and fixed type B-11 complete all specified and directed. 47 S&F aluminium anodised barrel tower bolt of extruded section 200mm longall as specified & directed by Engr-in-charge. 48 S&F 150mm long aluminium alloy handles, fabricated type, anodised complete all as specified & directed by Engr-in-charge. 49 S&F 150mm long Extruded brass handles, fabricated type, anodised complete all as specified & directed by Engr-in-charge. 50 S&F in repair vitreous china squatting pan Orissa pattern size 580 x 440 mm white with integral foot restsincluding concrete fixed complete all as specified and directed by Engineer-in-Charge. 51 S&F in repair vitreous china white wash down water closet pan, padestal pattern, white, including fixing bolts, but excluding flushing cistern and flush pipe and connection to drain (or out going pipe) etc. complete and making good to floor all as specified and directed 52 Supplyand fixplastic water closet seat, white, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device, seat and cover for water closet (European type) complete all as specified. 53 S&F vitreous china wash hand basin coloured Flat back of size 580x450mm,including 32mm dia chromium plated waste coupling long screwed shank andfly nut, flanged end bedded in red led cement and other end fixed and PVC waste pipe including cutting for and pinning in ends of brackets in CM 1:3 all as specified . 54 S & F in repair vitreous china wash hand basin white counter top (bowl type/oval shape) ofsize 630 x 450 mm,including 32mm dia chromium plated waste coupling long screwed shank andfly nut, flanged end bedded in red led cement and other end fixed and PVC waste pipe including cutting for and pinning in ends of brackets in CM 1:3 all as specified . 55 S&F in repairs PVC valve less, syphonic action type flushing cistern,10 ltrs capacitylow level, white, with inlet ball valve, float, handle and telescopic pipe flush pipe of polyethylene of low or high density or PVC, 32mm dia, for low level cistern and connection to pipes all as directed. 56 Supply & fixing pillar tap cast copper alloy with capstan head, chromium plated, fancy type screwed down, high pressure with or without letterHot or Cold with long shank and fly nuts screwed for iron pipe or for brass ferrule 15mm bore complete, all as specified & directed by Engineer-in-charge. Note :-The minimum weight of tap shall be as given in SSR or in relevant IS 57 Supply & fixing in repair pillar tap cast copper alloy with capstan head, chromium plated, fancy type screwed down, high pressure with or without letterHot or Cold with long shank and fly nuts screwed for iron pipe or for brass ferrule 15mm bore complete, all as specified & directed by Engineer-in-charge. Note :-The minimum weight of tap shall be as given in SSR or in relevant IS 58 S&Fbib tap 15mm bore cast copper alloy chromium plated long body fancy type with capston head and cup screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed by Engineer-in-Charge. 59 S&Fin repair bib tap 15mm bore cast copper alloy chromium plated long body fancy type with capston head and cup screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed by Engineer-in-Charge. 60 S&Fangle valve/stop valve 15 mm bore fancy type, cast copper alloy, chromium plated screwed down high pressure , screwed both ends for iron pipe or for union,complete, all as specified & directed by Engineer-in charge 61 S&Fin repair angle valve/stop valve 15 mm bore fancy type, cast copper alloy, chromium plated screwed down high pressure , screwed both ends for iron pipe or for union,complete, all as specified & directed by Engineer-in charge 62 Supply & fixing450 mm long PVC connection 15mm size with PTMT nuts complete all as specified & directed by Engineer-in-charge. 63 S&F in repair looking mirror of selected quality of size600 mm X 450 mm withbevelled edge mounted 6 mm thick commercial plywood and aluminium channel of required size fixed to wooden plugs with chromium plated brass screws and cup washers all as directed. 64 S & F 8 mm looking mirror of selected quality with bevelled edge mounted on stainless steel studcomplete all as specified and directed by Engr-in-charge. 65 S&F in repairtubular towel rail, Brass chromium plated 20 mm dia, Dtype, 60cm long between flanges complete all as specified and as directed by Engineer-in-Charge. 66 Taking down 15 mm dia steel GI tubing including all connectious fittings in any position including cleaning for re fixing the serviceable pipe all as directed. 67 Taking down 20 mm dia steel GI tubing including all connectious fittings in any position including cleaning for re fixing the serviceable pipe all as directed. 68 S&F 15 mm diagalvanised steel tubing medium grade including necessary fittings like sockets, tees, elbows, reducers, unions etcfixed to walls / ceilingcomplete all as specified and directed by Engineer-in-Charge. 69 S&F 20 mm diagalvanised steel tubing medium grade including necessary fittings like sockets, tees, elbows, reducers, unions etcfixed to walls / ceilingcomplete all as specified and directed by Engineer-in-Charge. 70 S&F 25 mm diagalvanised steel tubing medium grade including necessary fittings like sockets, tees, elbows, reducers, unions etcfixed to walls / ceilingcomplete all as specified and directed by Engineer-in-Charge. 71 S & F in repairs Vitreous China urinals, half stall complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2,securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement;grating and Union for discharge pipe complete all as specified and directed. 72 Supply & fixing in repairs CP swivel shower roses 125mm with or without swivel joints, including fixing to steel pipe or union fixed complete all as specified and directed by Engr-in-Charge. 73 S&F in repair brass chormium plated overhead shower 70 mm dia round shape single flow (ABS Body chrome plated with gray face plate) with rubit cleaning system with 240 mm arm & flange including fixing to 15 mm bore pipe complete all as specified and as directed by Engineer-in -charge ( Make : JAQUAR) (Shower Model No : Allied Cat No -EOS-491 & Make : JAQUAR, Arm Modle No -ALE-536A) 74 S&FCP brass stop valve/ angle valve fancy type 15 mm bore cast copper alloy screwed down high pressure fancy type with long shank and cup (Concealed type) fixed complete all as specified and directed by Engr-in-charge. 75 S&F in repair CP brass stop valve/ angle valve fancy type 15 mm bore cast copper alloy screwed down high pressure fancy type with long shank and cup (Concealed type) fixed complete all as specified and directed by Engr-in-charge. 76 S&Fgun metal globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed of 20mm bore fixed in repair all as specified. 77 Providing connection from existing pipe line by 50/40 mm bore ferrule complete all as specified 78 Dismantling floor, hearth or wall tilingincluding cement mortar bedding (but not backing), removingrubbish off the premises all as directed. 79 Dismantling of Brick tiles or terracing tiles, single layer on roofs and including rubbish off the premises complete all as specified and as directed by engineer-in-Charge. 80 M&L for Vitrified Ceramic tiles 8 to10 mm thick (square/ rectangular) light shade polished, area of each tiles exc 0.42 Sqm but not exceeding 1.00 sqm, in floor etc. over and including 15 mm thick screed bedding in cement mortar 1:6, set and jointed in neat cement slurry and pointed in white or coloured cement to match the floorcomplete all as specified and directed by Engneer -in-Charge 81 M&L for Vitrified Ceramic tiles 8 to10 mm thick (square/ rectangular) light shade polished, area of each tiles exceeding 0.42 Sqm and not exceeding 1.00 sqm,on vertical surfaces such as skirting / dados over and including 10 mm thick backing coat in cement mortar 1:4, set and jointed in neat cement slurry and pointed in white or coloured cement to match the floor complete all as specified and directed by Engneer -in-Charge 82 Demolition of cement concrete (unreinforced) in ground floor and paving not exceeding 15cm thickness below or above ground level of any description and in any position not otherwise specifically provided and removal of rubbish outside MOD land complete all asdirected by Engineer-in-Charge. 83 M & L for chequered cement concrete tiles with grey cement and pigment tiles 20 cm x 20 cm x 25 mm thick, set jointed and pointed in neat cement slurry in floors with grey cement and no pigments complete all as specified and directed 84 M & L for cement concrete tiles 25cm x 25cm x 22mm thick, m a c h i n e pressed with grey cement and pigment over cement screed base laid over and including15 mm thick screed bed incement mortar 1:6, set and jointed with grey cement slurry mixed with pigment and no pigmentin floors/roof, and cut and polished complete all as specified and directed. 85 Demolitionof brickwork or stone / boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc. but excluding ashlar facings, dressed stone work and precast concrete articles including cleaning and stacking serviceable brick for re use and balance removing rubbish from the site complete all as specified and as directed by Engineer-in-charge. 86 Taking down cement plaster from brick wall or concrete surfaces or ceiling including raking out joints, hacking for key & scrubbing down with water etc complete all as specified and directed. 87 M&L for two coats of acrylic distemper on newly plastered surfacesof walls over and including one coat of primer and 3mm thick wall care putty including preparation of surfaces complete all as specified and directed. 88 M&L for complete removal of existing treatment and two coats of acrylic distemper over 3 mm thick wall care putty onplastered surfaces of walls including preparation of surfaces complete all as specified and directed by Engineer-in-Charge. 89 M&L for preparation of new plastered and applying two coats of weather proof exterior emulsion paint (Apex ultima or equivalent) over a coat of primer over3 mm thick wall care putty complete all as specified and directed by Engineer-in-charge. 90 M&L for preparation of old surface of existing treatment and applying two coats of weather proof exterior emulsion paint (Apex ultima or equivalent) over a coat of primer over 3mm thick wall care putty complete all as specified and directed by Engineer-in-charge. 91 M&L for preparation of old surface of existing treatmentand applying two coats of white wash on ceilingsurfaces complete all as specified and directed by Engineer-in-charge. 92 M&L for preparation of old surface of existing treatment and applying two coats of white wash on wall complete all as specified and directed by Engineer-in-charge. 93 Demolition mud in roofs, any thickness, including plastering and leeping and including rubbish off the premises complete all as specified and directed. 94 M&L for Roof treatment to RCC roof as follows:-(a) Cleaning the roof surfaces thoroughly using wire brusehes to remove sharp projections, cleaning joints, washing, drying and removing all dirt/dust to receive concrete padding/plaster etc. (b) Providing 15 mm thick screed bed or bedding layer of cement mortar (1:4) with WPC, finished even and smooth without using extra cement. (c) Providing one coat of approved bituminous primer @100 gms per sqm, over dried plastered surface. (d) Laying 3 mm thick APP membrane,(mineral finish) reinforced with non woven polyster fabric, by torch application. The overlapping while torching shall be 75 mm on longitudinal direction and 100 mm on the transverse direction complete all as specified and directed by E-in-Charge.Make : STP Dr Fixit/Pidilite, Texsa India Ltd/Tikitar Dansona/Bengal BitumenNotes : (i) All joints and change in directions should be covered wih cement mortar (1:3) mixed with SBR latex @ 200 ml/bag of cement/as per site reqmt and cured well before laying membrane by torching.(ii) All angles and abuttments should be sealed well with extra care to ensure full bondage. (iii) Water proofing treatment shall be got carried out by approved authorised applicator of manufacturer only. The name of firm shall be got approved from GE before carrying out the wk. (iv) The independent testing of membrane for technical parameters given in particular specifications shall be carried out from Govt approved labs having fascilities for testing of membrane. (v) The guarnatee of treatment shall be for min 10 yrs reckoned from date of completion of whole wk. 95 M & L for 50 mm thick cement concrete 1:2:4 type B-0, using 12.5mm graded stone aggregate as in roof Padding etc and slope 1:40 complete all as specified and directed by Engineer-in-Charge. 96 M&L 40mm thick brick tiles laid flat on cement concrete& joints grouted flush in cement mortar (1:3) beddedover15mm thick cement morter (1:6)mixed with 5% of crude oil by weight of cement on complete all as specified and directed by Engr-in-Charge. 97 Taking down chowkhats or frames n.exc 1.5 sq. meach with shutters (without taking off shutters from the frame) complete all specified and directed directed. 98 Taking down chowkhats or frames exc 1.5 sq. m but n.exc 4.0 sq. m each with shutters (without taking off shutters from the frame) complete all specified and directed directed. 99 S&F for powder coated aluminium frame for doors, windows, ventilators and aluminium partition with one or more rebates including jointing cleats glazing clips, rubber packing, anodised aluminium snap beading, screws etc complete with locking arrangements for fixing with powder coating on aluminium sections, minimum thickness of poweder coating shall be 50 micron as per the specification. The top and bottom horizontal members and vertical members adjacent to wall shall be fixed with floor, ceiling, walls and cills where required and fixed with the help of rawl plugs and screws or with fixing clips or with expansion hold plate fastners. Aluminium section shall be smooth, rust free, straight, mitred and jointed mechanically whereever required complete in all respect all as specified & directed by Engr-in-Charge. 100 S&F for powder coated anodised aluminium door shutters,, aluminium sections weighing exc 0.55 Kg/m including necessarynecessary joining cleats, glazing clips, rubber neoprene packing, handles 1 Nos in each door, hinges (03 Nos),anodised aluminium snap beading, screws,complete all as specified 101 S&F in repairs mild steel mortice lock 4 lever vertical type, size 100mmbrass complete all as specified. 102 S&F for 35 mm thick 2nd class hard wood factory made glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a) complete all as specified and directed. 103 S&F 300 mm long aluminium sliding bolt plate type stove enamelled black with bright bolt not less than 16 mm dia with and including a minium of 6 bolts and nuts four on bolt plate and two on stapple plate and fixed complete all as specified 104 S&F Stainlesssteel wire cloth 0.36 mm nominal dia of wire and avarage width of aparture 1.40mm and fixed etc., complete all as specified 105 M&L for preparation of new or previously untreated wooden surface of any description not otherwise described over 10 cm width or girth and apply two coats of synthetic enamel paint over one coat of pink primer all as specified. 106 M&L for preparation of old wooden surface of any description not otherwise described over 10 cm width or girth and apply one coats of synthetic enamel paintall as specified. 107 Supplyfor door closer hydraulically regulated of aluminium cast type , designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed other parts made of mild steel heavy duty and fixed complete all as specified and directed. 108 Supply only 300mm mild steel helical door springrat tail type including roller platecomplete all as specified and directed by Engineer in Charge 109 S&F in repair drapery stainless steel rods, standrad quality, not less than 25mm dia with brackets and heads at both ends, etc. complete all as specified and directed by Engr-in-charge. 110 Supply and fix in repair ceramic wall mounted commode one piece water closet commode western toilet/commode 6D flushing technology/EWC/European commode in standard Size 53 x 37 x 36 cm with soft close seat cover for bathrooms complete all as specified and directed by Engineer-in-ChargeMake : Hindware Cat No B0B691WPYN, Pareware Cat No B0C3RMVG1H, Cera Cat No B09N6SBGTS 111 S & F in repair of wall mixer with L bend 115 mm long full system brasscast copper alloy chromium plated, mixer for mixing hot & cold water suitable for bathing, screwed down for iron pipe 15 mm bore complete all as specified and as directed by Engineer-in -charge 112 S&F in repair brass CP plated health faucet with 1 mtr tube & hookcomplete all as specified and directed by Engneer -in-Charge 113 S&F in repair stainless steel chromium plated jet spray (butter fly or L bend) suitable for EWC including 1m tube and necessary nut bolts complete all as specified and as directed by Engineer-in-charge. 114 Supply and fixing in repairglass corner shelf 200 mm with ABS brackets complete all as specified and directed by Engineer-in-Charge. 115 S&F in repair chromium plated fancy type soap dish complete all as specified and directed 116 S&F in repair stainless steel Trap with grating round or square 150mm size (minimum weight 100gms) complete all as specified and as directed by Engineer-in-charge. Note :- The minimum weight shall be as given in SSR or in relevant IS. 117 S & F in repairtoilet paper holder Vitreous china, box type, coloured, fixed to wall with brass screw complete all as specified and directed by Engineer-in-Charge 118 S & F in repair brass chromium plated PEG Set of 6complete all as specified and as directed by Engineer-in-charge. 119 Taking down eaves gutters and rainwater pipes (any size or pattern) including all fittings, heads, shoes, bends, swan-necks etc., including cleaning or refixing or removal to Store (measured overalll as fixed along the cente line over fittings and accessories) complete all as specified and directed by Engineer-in-Charge 120 S&F 110 mm dia PVC SWR pipe, single socketed in any length with rubber ring joints, laid in trenches or in floors all as directed. 121 S&F 75 mm dia PVC SWR pipe, single socketed in any length with rubber ring joints with clamps to wall all as directed. 122 S&F 110 mm dia PVC (SWR) bend any radius all as directed. 123 S&F 75 mm dia PVC (SWR) bend with access door any radius all as directed. 124 S & F for 110 mm PVC (SWR) junction single, (Single T) equal or unequal provided with access door complete all as specified and directed by Engr-in-charge. 125 Supply & fixingPVC (SWR) vent cowl 110mm bore complete all as specified & directed by Engineer-in- charge. 126 S&F PVC (SWR) floor trap 75mm dia with grating including jointing with solvent cement complete all as specified and directed. 127 Cutting into existing manholes for connection of new drain making pipes and rendering cutting out existing benching & forming branch channel in PCC 1:2:4 type B1 smooth finished & forming benches as reqd etc for 150 mm bore all as directed. 128 S&F for Rotational moulded polythene water storage tank 500 ltr capacity vertical with closed top hoisted and fixed in position all as specified in SSR part-I. all as directed andincluding 20 mm bore PTMT float valve, connection nipple 2 Nos complete all as specified and directed.. 129 Supply and laying DWCPE (SN8) 180 (OD)/163 (ID) mm diameter drain pipes as per IS-16098 (Part-II), laid in trenches onPCC bed to required slope, including all accessories/fittings, jointing and tested complete all as specified and as directed by Engineer-in-Charge Note : (PCC & Earth work shall be measured and paid separately). 130 M&L for PCC 1:2:4 type B2 using40mm graded aggregates as in benching / haunching ofmanholes including forming channels including necessary formwork etc complete all as specified and directed by Engr-in-charge. 131 M&L precast cement concrete 1:2:4 type B1 using 20mm graded stone aggregate and set cement mortar 1:6 as in cover slabs (for manholes etc,) chajjas, shelves and similar articles with plain faces complete all as specified and directed by Engr-in-charge. 132 Material and labour for repair to damage RCC coloumns/Beam/Slab/Chajja by using micro mortar and concrete in Following Stages :-(a)Removing the mortar and loose concrete from RCC elements.(b)Cleaning the rusted reinforcements and applying rust removal.(c)Inserting the addl reinforcements in case the coves sectional area reduction is more than 20 percent by welding the reinforcement with existing bars and supporting adequate on walls if reqiurd with grout.(d)Providing micro morter and concrete over bond coat to cover the reinforcements and slet surface.(e)Providing adequate formwork and scaffolding if required.(f) Curing the surface.Note :- (i)Rust removal, bonding agent, grout, micro mortar and concrete and related chemicals shall be of Dr Fixit/BASF and STP(ii) Work is to be got executed from authorised applicator of the company.(iii)Steel reinforment shall be measured and paid separately 133 M&L for Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates and conforming to Fe 290 (Gde- E- 165) quality- A complete all as specified and directed 134 S & F pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. 135 E/M ProtionSupply and laying un-reinforced precast concrete cover, class LV, type 2, flat, size 300 mm x 180 mm x 40 mm completeall as specified and directed. 136 Supply and laying and commissioning LT XLPE cable 1100 Volt grade 35 Sqmm 3.5 Core with stranded aluminium conductor PVC sheathed armoured confirming to IS 1556 laid in trenches/along poles/ through pipe/through duct completeincluding taking out of existing cablel all as specified and directred.Excavation and earthwork shall be paid and measured separately 137 Supply and laying and commissioning LT XLPE cable 1100 Volt grade 50 Sqmm 3.5 Core with stranded aluminium conductor PVC sheathed armoured confirming to IS 7098 (Part-I) laid in trenches/along poles/ through pipe/through duct completeincluding taking out of existing cablel all as specified and directred.Excavation and earthwork shall be paid and measured separately 138 Supply and laying and commissioning LT XLPE cable 1100 Volt grade 10 Sqmm 4 Core with stranded aluminium conductor PVC sheathed armoured confirming to IS 1556 laid in trenches/along poles/ through pipe/through duct completeincluding taking out of existing cablel all as specified and directred.Excavation and earthwork shall be paid and measured separately 139 Supply and fix XLPE insulated armoured heavy duty electric cable with Aluminium conductor 1100 Volt grade 25 Sqmm 3.5 core complete all as specified and directed by Engineer-in-Charge 140 Supply and laying GI tubing light grade 40 mm dia for protection of cable/laid in trenches/fixed on pole/walls/laid under floors/roads includign fitting complete all as specified and directed. 141 M & L for Cross arms, bracings, Stiffeners supports, D-clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot,drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, oneunder coat and one finishing coat of paintcomplete all as specified and directed. 142 M & L for Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws asspecified type 410 SP-22 (9 metres long) including paintin of poles with two coats of synthetic enamel paint over a coat of primer in alternate strip of 30 cm each in black and white colour upto 1.5mtr height from top of PCC pedestal/copping of poles and numbering of poles with synthetic enamel paint white in 80 mm high letter over 150 mm x230 mm black base made from synthetic enamel paint including dismantling of old U/s pole and removing from site compelete all as specified anddirected Note : Earth work and PCC work shall be measured and paid seperately (Old pole shall be deposited in MES store yard 143 Supply and fixing energy efficient LED street light fitting of 90 W pressure die cast aluminium housing/body, heat resistant clear toughened glass,better optics for uniform distribution street/Roadway luminaire, with driver, fixing the light fitting , complete fitting with all accessories and following specifications,complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 100 Lumen per watt.(b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 50°C (d) Power factor : Minimum 0.95(e) THD : Max10%.(f) IP rating : Minimum IP65. (g) IK rating:Minimum IK07 (h) Built in potted LED Driver of the make as of the luminaire. (j) LED driver should be complete with all protections vizopen/short circuit protection, over voltage protection, all as per standard design of manufacturer.(k) Surge protection 10 kV (inbuilt + extended) (l) CCT : 5700 K. (m) CRI: Morethan 70 (n) Lens - High Efficiency wide angle lens. (o) BIS Approved fixtures and driver (p) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily) 144 Supply and fixing street light bracket made out of 40 mm dia GI tubing medium grade made to shap 1.5 Mtr long with fixing arrangement for LED fittings duly painted with two coats of synthetic aluminium paint over a coat of primet including MS clamps and back plates fabricated from steel section including nuts, bolts washer etc complete all as specified and directed 145 Supply and fixing in replacement LT cable junction box, dust and water proof (IP65), out door type, made out of Polycarbonate with glass fiber re-inforced, size of box 200 x 160 x 98 mm with swinging cover and locking clamp, pole mounting, consisting of aluminium bus bar strip 150mmx 20mm x 3mm, 4 Nos mounted on PVC insulator andprovision of incoming/outgoing cables with gland, including in built 6Amp MCB, SP, 9/10KAone No complete all as specified and as directed by Engineer-in-charge. Note : Rate deemed to be inclusive of MS clamps and nut bolts for fixing the box along pole. 146 Supply and fixing PVC insulated stranded aluminium conductor cable PVC sheathed 1.5 Sq.mm flat or circular twin core with & including PVC heavy duty conduit of sixe 20 mm bore fixed to poles with suitable size clamps for connection of street light fitting from junction boxes complete all as specified and directed Note : MS Clamps shall be measured and paid separately 147 M & L for plain cement concrete 1:2:4 type B-1, using 20 mm graded crushed stone aggregate as in coping & bed block etc including weathering, slightly, rounded or chamfered angles and throating as directed necessary form work complete all as specified and directed. 148 M & L for danger notice plate of size 25 cm x 20 cm made out of MS sheet 1.6 mm thick, vitreous enameled white, with letters figured and convertional skull and bones in signal red colour and fixed with MS clamps, bolts, nuts of approved size, for HT poles compplete all as specified and directed 149 M&L for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth of not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick and packed layer of charcoal dust and common salt, connected to earth lead ofGI wire 4 mm dia (8 SWG) by means of bolts, nuts and washers of the earth wire.galvanised iron or steel and thimbles and other end of the earth wire connected to earthing test point and protected by galvanised iron pipe light grade 15mm dia and water pipe 20mm dia GI light grade with funnel and wire mesh, PCC chamber in cement concrete (1:2:4) type B-1and CI cover with frame all as shown in electrical plate No. 3 of MES Schedule Part-I of SSR-2009. Notes :- (i) 20 mm dia GI pipe for watering to be provided with a socket and plug and should be 10 cms above ground level. (ii) Outer edge of earth pit will be 1 metre away from the outer edge of PCC chamber. (ii) GI wire upto DBs earth connection is included in this item.(iii) Water pipe shall be provided in slanting position 150 S & Fin repair for feeder pillar box out door type made out of 3 mm thick plain MS sheet of size 0.90 mx 0.45 mx 0.90 m supported on angle iron of size 40 x 40 x 6 mm including necessary PCC for grouting.The panel shall comprise of (a) 4 Nos aluminium bus bar of 300 Amp rating (b) MCCB3- pole 415 Volt, 200 Amp, ruputing capacity 10 KA-01 No (c) MCCB 3-pole 415 Volt, 100 Amp 25 KA-01 No (d) MCB SP 5-32 Amp-06 Nos 151 Supply & fix in replacement offlood light fitting powder coated pressure die cast aluminium housing with mirror optic reflector toughened glass cover with high power LED, 120 watt 240 volt 50 Hz and unique peanut lens with optics for uniform distribution with SMPS complete with drivers and LED, connectors prewired complete allas directed by engr in charge. 152 Supply & fix in replacement offlood light fitting powder coated pressure die cast aluminium housing with mirror optic reflector toughened glass cover with high power LED, 100 watt 240 volt 50 Hz and unique peanut lens with optics for uniform distribution with SMPS complete with drivers and LED, connectors prewired complete allas directed by engr in charge. 153 Taking down carefully existing aluminium/copper point wiringfor light, fan, socket or power bell complete with fittings such as Switches, sockets, ceiling roses, holders, call bells & making goodthe disturbed surfaces of walls, matching the colour with existing surface complete all as specified and directed.Note : Rate for making good shall be deemed to be included in above item rate. 154 M&L for concealed point wiring for one light point/ fan point/bell pointcontrolled by one switch with 1.5 Sqmm (nominal cross section area) FRLSH PVC insulated unsheathed multistranded copper conduct cable in and including medium grade rigid PVCconcealed conduit in wall after cutting chases in wall including cast iron or pressed steel terminal box covered with and including 3 mm thick bakelite sheet top cover fixed flush with wall using brass screws, washers and 1.5 Sqmm single core PVC insulatedunsheathed copper conductor wire as earth continuity to common earth and connecting to earth dolly and making good diturbed surfaces in cement motar 1:3 complete all as specified and directed. 155 All as per srl item No 154 above but One socket out let 5/6 amps point controlled by one switch on the same board completed all as specified and as directed by Engineer-in Charge 156 All as per srl item No 154 above but One socket out let 5/6 amps point controlled by one switch onindependend board completed all as specified and as directed by Engineer-in Charge 157 All as per srl item No 154 above butpoint wiring with 4 sqmm multi stranded conductor cable and4 sqmmunsheathed copper conductor earth wire for two in one 5 pin 15 Amps socket outlet on independent board complete all as specified and directed. 158 Material and labour for concealed Point wiring for one light point controlled complete with 2.5 Sqmm(nominal cross section area) single core FRLSH PVC insulatedunsheathed and multi strand copper conductor cable 1100 volt (ISI marked)drawn through andincludingPVC conduit 20mm dia (medium duty, ISI marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction boxes etc., including Pressed steel powder coated sunken terminal box suitable for modular switch socket (Min 50mm deep and 1.6mm thick sheet, suitable size ) concealed in wall, including inner and outer plates (cover plate) suitable for fixing the modular switch, including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3), including fixing ofswitches complete all as specified and as directed. (switches shall be measured and paid separately under appropriate item of BOQ as supply only but cost of labour for fixing the same shall deemed to be included in the unit rate. ). 159 Supply onlyModular switch 1 way 6 A, one way(1 module) complete all as specified and as directed. 160 Supply onlyModular switch 1 way 6/16A, one way(1 module) complete all as specified and as directed. 161 Supply only Modular bell push switch 6A, 1 Module all as specified and directed by Engineer-in- Charge 162 Supply only modular Socket outlet multipurpose type 6 Amp, flush type (2 module) complete all as specified and as directed by Engineer-in-charge. 163 Supply only modular Socket outlet multipurpose type 6/16 Amp, flush type (2 module) complete all as specified and as directed by Engineer-in-charge. 164 Supply and fixing Batten holder polycarbonate cased body (B22 base), top line series, with back plate complete all as specified and as directed. 165 Supply and fixing Ceiling Rose, polycarbonate, isolated body, surface bakelite 3 terminal, 240 volts, 5/6 Amp complete all as specified and as directed. 166 Supply and fixingelectric calling Bell Ding Dong type, AC 230 Volts single pole including making elctric connection complete all as specified and as directed by Engr-in-charge. 167 Supply and fixing single pole and neutral sheet metal enclosure with a two pin and earth plug and socket complete with one single pole MCB of capacity 20 Amps, 240 volts, AC supply complete all as specified and directed by Engineer-in-Charge. 168 Supply and fixing LED tube light fitting polycarbonate housing 1 x 20Watt, appx 4 feet long, with decorative box linear, housing environment friendly, including electric connection with using 2 core flexible copper conductor cable 23/0.00076 from ceiling rose to tube fitting, complete fitting with all accessories and following specifications, complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 110 Lumen per watt.(b) Input Voltage range : 140 to 270 volts.(c) Temp operating range : Minus 5°C to Plus 45°C(d) Power factor : Minimum 0.95 (e) THD : Current THD Max10% and voltage THD max 5%(f) IP rating : IP-20.(g)LED Driver of the same make as of the luminaire.(h) LED driver should be complete with all protections vizopen/short circuit protection, over voltage protection, all as per standard design of manufacturer.(j) Surge protection minimum 2.5 kV. (k) CCT : Minimum 6000K(l) CRI : Minimum 80 (m) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily) 169 Supply and hanging /fixing ceiling fan 1200 mm sweep AC Supply (Input Voltage Range ; 120 to280V), BLDC type, 5 star rated, BEE and ISI Marked super enamelled, copper winding of B class insulation, single phase, maximum 30W (± 10%), Temperature rise 40 degree maximum without remote with and including capacitive regulator, 03 No blades, down rod including accessories, white colour, total harmonic less than 10%, 5 speed, hanging in position including making connection with flexible cord three core twisted copper conductor of suitable sizefrom ceiling rose to fan complete all as specified.Note :- (i) Serial Number as issued by Engr-In-Charge of celing fan and GE Office name shall also be written on fan with red colour permanent marker and fixing of regulator on switch board, cost for the same shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account 170 Supply and fixing ventilating Air fresher Fan of size 250mm sweep, AC single phase 230V 50Hz, 1200RPM, copper winding, made of sturdy Engineering plastic complete with louvers shutter, including provision of cutting of wall for suitable opening as per fan and making good the disturbed surface as per existing, including electric connection with PVC Sheathed copper conductor flexible cable of suitable size drawn in flexible PVC conduit from ceiling rose to fan complete all as specified and as directed by Engineer-in-charge.Note:- (i) Serial Number as issued by Engr-In-Charge of fan and GE Office name shall also be written on fan with red colour permanent marker, cost for the same shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account. 171 Supply & fix fresh air fan 230 mm sweep, single phase 230v 50 Hz plastic body with louvers, including grouting with fasteners, nuts/bolts etc complete all as specified and directed by Engineer-in-Charge 172 Material and labour for concealed sub main wiring (using colour coding such as red, black, white, green colour or as directed) with 6 Sqmm single core (03 run i.e 2 runs for main phase and neutral, 01 run for continues as earth wire) FRLSH PVC insulated unsheathed multistrand copper conductor cable drawn through and including PVC conduit 25mm dia (medium quality ISI marked), for independent circuit including all fitting arrangement i.e. PVC clamp, rawl plug, screw, PVC junction box, tee, bend etc. and including cutting of chases in wall and making good disturbed surfaces of walls as per original complete all as specified and as directed.Note :- Three runs of copper conductor 6 Sqmm cable and one run of PVC conduit including accessories shall be measured and paid as one unit (one RM length) for payment and extra length of cables required for connection to MCBs/DB shall not be measured and the cost for the same shall deemed to be included in the unit rate. 173 Supply and fixing (concealed flush to wall) factory made DB (made out of CRCA sheet not less than 1.2mm thick, fitted with DIN channel neutral link and 200 Amp rated bus bar) SPN, 12 Way 240V, suitable for mounting MCB/Isolator etc, conforming to IS-13032, DB shall be semi glosy finished with epoxy polyster based powder paint sprayed and backed at high temperature between powder paint process to ensure smooth finish and protection against corrosion atmosphere. The DB shall be double door type with hinged door with locking arrangement, the DBs shall be same make as MCBs, DB shall be provided with level marking indicating the incoming and outgoing circuits on always as specified. The DBs shall be of IP-43 protection class, and including making good disturbed surfaces of walls as necessaty complete all as specified and directed by Engineer-in-charge.Note :- MCB/Isolator etc shall be measured and paid separately under appropriate item of BOQ. 174 Supply and fixing (concealed flush to wall) factory made DB (made out of CRCA sheet not less than 1.2mm thick, fitted with DIN channel neutral link and 200 Amp rated bus bar) SPN, 8 Way 240V, suitable for mounting MCB/Isolator etc, conforming to IS-13032, DB shall be semi glosy finished with epoxy polyster based powder paint sprayed and backed at high temperature between powder paint process to ensure smooth finish and protection against corrosion atmosphere. The DB shall be double door type with hinged door with locking arrangement, the DBs shall be same make as MCBs, DB shall be provided with level marking indicating the incoming and outgoing circuits on always as specified. The DBs shall be of IP-43 protection class, and including making good disturbed surfaces of walls as necessaty complete all as specified and directed by Engineer-in-charge.Note :- MCB/Isolator etc shall be measured and paid separately under appropriate item of BOQ. 175 Supply and fixing MCB ‘C’ curve suitable for 230 volts AC supply, 6 to 32 Amps, SPN with over load and short circuit protection and rupturing capacity not less than 10 KA,fixing in DB complete all as specified and as directed by Engineer-in-charge 176 Supply and fixing MCB ‘C’ curve suitable for 230 volts AC supply, 06 to 32 Amps, SP with over load and short circuit protection and rupturing capacity not less than 10 KA,fixing in DB complete all as specified and as directed by Engineer-in-charge 177 Supply and fixing blanking plate suitable for any type of DB complete all as specified and as directed by Engineer-in-charge. 178 Supply and fixingLED light fitting 1 x 10Watt, appx 2 feet long with decorative ultra ceiling square profile linear LED lighting fixture with extruded polycarbonate environment friendly, including electric connection with using 2 core flexible copper conductor cable 23/0.00076 from ceiling rose to light fitting,complete fitting with all accessories and following specifications, complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 110 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 5°C to Plus 45°C(d) Power factor : Minimum 0.95(e) THD : Current THD Max10% and voltage THD max 5% (f) IP rating : IP-20. (g) CRCA pre coated housing with plastic end cap.(h) LED Driver of the same make as of the luminaire. (j) LED driver should be complete with all protections vizopen/short circuit protection, over voltage protection, all as per standard design of manufacturer. (k) Surge protection minimum 2.5 kV.(l) CCT : Minimum 6000K(m) CRI : Minimum 80(n) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily) 179 Supply and fixing LED Bulkhead fitting 1 x 10Watt, complete with Standard LED lighting fixture with extruded polycarbonate housing environment friendly, including electric connection with using 2 core flexible copper conductor cable 23/0.00076 from ceiling rose to light fitting, complete fitting with all accessories and following specifications complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 100 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 5°C to Plus 50°C(d) Power factor : Minimum 0.95 (e) THD : <15%. (f) IP rating : IP-65. (g) CCT : Minimum 5400K (h) Polycarbonate housing white coloured (j) LED Driver of the same make as of the luminaire. (k) LED driver should be complete with all protections vizopen/short circuit protection, over voltage protection, all as per standard design of manufacturer.(l) Surge protection minimum 2.5 kV.(m) CRI : Minimum 80 (n) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily) 180 Supply and fixing energy efficient LED security light fitting of 35W pressure die cast aluminium housing/body, heat resistant clear toughened glass,better optics for uniform distribution street luminaire, with driver, including electric connection with using 2 core flexible copper conductor cable 1Sqmm from ceiling rose to light fitting, fixing the light fitting with new bracket made out of GI tubing light grade 32mm dia, 1.5 metre long bent to shape at 120 degree angle at half metre from bottom, including two Nos clamps made out of MS Flat iron size 25x3 mm with suitable nuts and bolts for fixing of bracket including painting to MS clamp and nut bolts with two coats of aluminium paint over a coat of red oxide primer, complete fitting with all accessories and following specifications, complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 110 Lumen per watt.(b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 50°C (d) Power factor : Minimum 0.95(e) THD : Max10%.(f) IP rating : IP66. (g) IK rating:Minimum IK07 (h) Built in potted LED Driver of the make as of the luminaire.(j) LED driver should be complete with all protections vizopen/short circuit protection, over voltage protection, all as per standard design of manufacturer.(k) Surge protection 10 kV (inbuilt + extended) (l) CCT : 5700 K. (m) CRI: Minimum 70 (n) Lens - High Efficiency wide angle lens. (o) BIS Approved fixtures and driver (p) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily) 181 Supply, installing, commissioning and testing of electric water heater (Geyser, vertical type) storage type ABS body with 3 level safety, capacity 25 litre, BEE approved 5 Star rating, 230 V , single Phase, AC supply, inner tank made out of heavy duty stainless steel sheet with feroglas coated (Designed with single weld line, factory tested with hydraulic pressure as per latest IS code) complete with all accessories such as safety valve, thermostate, NRV, connection piece PVC connection for hot and cold water of suitable length, three core PVC insulated PVC Sheathed copper conductor flexible cable,including 04 no Nut bolt grouting in wall in PCC (1:2:4) using 12.5mm graded stone aggregate for hanging the geyser and making good the disturbed surface complete all as specified and directed by Engr-in-Charge. 182 Supply and fixing LED lamp minimum 3 star rated 9W LED B-22 base complete all as specified and directed by Engr-in-Charge with following specifications(a) Lumen system efficacy of lamp should be minimum 100 Lumen per watt.(b) Input Voltage range : 140 to 270 volts(c) Temp operating range : Minus 10°C to Plus 45°C(d) Power factor : Minimum 0.95(e) CRI: More than70 183 Supply and fix piano swith flush button single pole one way 5 Amps complete all as specified and directed 184 Supply and fix piano swith flush button single pole one way 15 Amps complete all as specified and directed 185 Supply and fix socket 3 pin 5 Amp (with 2 Pin outlet of 5 Amp also) outlet mulipurpose use, flush mounting type 230/250 volts grade on top cover 186 Supply and fix socket 3 pin 15 Amp (with 2 Pin outlet of 5 Amp also) outlet mulipurpose use, flush mounting type 230/250 volts grade on top cover 187 Supply and fixing lamp holder, PVC / polycarbonate type with back plate complete all as specified and directed by Engineer-in-Charge 188 Supply & FixMCCB TP with thermal Megnatic release, breaking capacity16 KA, rating 100 Amp, 3 pole, 415 volts including taking down existing U/S MCCB all as specified and directed. 189 Note:- The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender, from total amount of Schedule A/BOQ

Key Value

Document Fees
INR 500 /-
EMD
INR 70000.0 /-
Tender Value
INR 35 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Notice 0 KB
Click here to download tender document Tender Document 0 KB
Click here to download tender document Tender Document 0 KB
Click here to download tender document Tender Document 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail