}

Tender For Repair/Replacement Of Summer Cooling Appliances And Connected Works At Binnaguri Military Station Under Ge (North) Binnaguri., binnaguri-West Bengal

Statutory Bodies & Commissions/Committees has published Tender For Repair/Replacement Of Summer Cooling Appliances And Connected Works At Binnaguri Military Station Under Ge (North) Binnaguri.. Submission Date for this Tender is 21-10-2024. Screws Tenders in binnaguri West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

45359761
Corrigendum : Tender For Repair/Replacement Of Summer Cooling Appliances And Connected Works At Binnaguri Military Station Under Ge (North) Binnaguri.
Open Tender
Indian
West Bengal
Binnaguri
21-10-2024

Tender Documents

Tender Details

Tender For Repair/Replacement Of Summer Cooling Appliances And Connected Works At Binnaguri Military Station Under Ge (North) Binnaguri.; 1 REFRIGERATORDismantling of defective refrigerator of any make and capacityincluding transportation to workshop and back for thorough checking of all accessories and components, repairs and reassembling the same after repair/replacement of defective accessories/components and testing complete all as specified and as directed. Note :- New accessories / components required shall be measured and paid separately, labour charges for fixing shall be included in the unit rate of item No. 1 here-in-above. Repair of body overhauling / repair sealeds unit (compressor) gas charging painting etc shall be measured and paid separately. Old serviceable accessories / components obtained from item No.1 here-in-above shall be refixed as directed by the Engr-in-charge and labour charge for refixing to be deemed to be included in unit rate of item No.1 here-in-above. 2 Supply only the following suitable accessories components of refrigerator (Make - Kelvinator/Allwyn /Godrej/Whirlpool/Usha/Samsung/LG) :- 3 Cooling chamber including cooling coil of existing size shape suitable for refrigerator of size and of capacity 165/180 ltrs complete all as specified and as directed. 4 All as per item No 3 here-in-above for refrigerator of capacity 250/286/310 ltrs complete all as specified and as directed. 5 Thermostat defrost type switch suitable for refrigerator of capacity 165/220/310 ltrs complete all as specified and as directed. 6 PTC Relay with overload protection suitable for refrigerator of capacity 165 to 300 ltrs complete all as specified and as directed. 7 Cooling coil of suitable for size of refrigeration capacity of 250/280/310 ltrs complete all as specified and as directed. 8 Magnetic door gasket including fixing accessories for refrigerator of 165/180 Ltrs capacity complete all as specified and as directed. 9 Magnetic door gasket including fixing accessories for refrigerator of 250/286/310 Ltrs capacity complete all as specified and as directed. 10 Capillary tube of size 0.36 for any type/size refrigerator complete all as specified and as directed. 11 Thermostate suitable for 250/286/310 ltr complete all as specified and as directed. 12 Door switch for refrigerator of any capacity complete all as specified and as directed. 13 Lamp holder, screwed/pin type including 15 watt, lamp 240 volts complete all as specified and as directed. 14 LED lamp suitable for refrigerator of capacity 165/250/310 ltrs complete all as specified and as directed. 15 Copper pencil strainers of size 4 long double mouth complete all as specified and as directed. 16 Inner shelf for refrigerator of capacity 165/180 ltrs complete all as specified and as directed. 17 All as per item No 16 here-in-above but for refrigerator of 286 to 310 ltrs capacity complete all as specified and as directed. 18 PVC chiller tray for refrigerator of capacity 165 ltrs complete all as specified and as directed. 19 All as per item No 18 here-in-above but 286 to 310 ltrs complete all as specified and as directed. 20 Wiring set complete consisting of PVC insulated flexible wire with stranded copper conductor of size 1.5 sqmm and fixing clips for refrigerator all types complete all as specified and as directed. 21 Vegetable tray for 165 to 190 ltrs refrigerator complete all as specified and as directed. 22 Vegetable tray for 286 to 310 ltrs refrigerator complete all as specified and as directed. 23 Freezer door for165 ltrs refrigerator complete all as specified and as directed. 24 Freezer door for 286 to 310 ltrs refrigerator complete all as specified and as directed. 25 Bimetal 2 wire / 3 wire / 4 wire complete all as specified and as directed. 26 Running capacitor 6 / 10 mfd complete all as specified and as directed. 27 Forst free fan motor SP 230 volts complete all as specified and as directed. 28 Sensor for cooling coil complete all as specified and as directed. 29 Condenser coil for 165 to 200 Ltrs complete all as specified and as directed. 30 Condenser coil for 250 to 310 Ltrs complete all as specified and as directed. 31 M&L for replacement to PCB of refrigerator of 165 to 310 ltr capacity and make complete all as specified and as directed. 32 M&L for replacement to inverter type PCB of refrigerator of 165 to 310 ltr capacity and make complete all as specified and as directed. 33 Supply and charging of Gas R-134 A or equivalent including necessary arrangement for charging gas & pressure testing complete all as specified and as directed. 34 Supply and fix of heating coil including fixing accessories suitable for 250/286/310 ltrs complete all as specified and as directed. 35 Supply and fix of T-Fuse for refrigerator of cap 250/286/310 complete all as specified and as directed. 36 Taking out burnt compressor after disconnecting suction and discharge line and supply and fixing new compressor as per existing including testing complete all as specified and directedfor Refrigerator of Capacity 165/180 Ltrs complete all as specified and as directed. Note: Recharging of gas will be measured and paid separately. 37 All as per item No 36 here-in-above but for compressor of capacity of refrigerator 250/286/310 ltrs complete all as specified and as directed. 38 Recharging of refrigerator gas (R-134)for refrigerator of capacity 165 to 185 ltrs after vacuuming dehydration leak testing of the system as per system standard practice for proper cooling effect and satisfactory performance complete all as specified and as directed. Note: Recharging of gas will be measured and paid separately. 39 All as per item No 38 here-in- above but for refrigerator of capacity 286 to 310 ltrs complete all as specified and as directed. 40 Supply and charging Gas R-600including necessary arrangement for charging gas & pressure testing complete all as specified and as directed. 41 WATER COOLERDismantling of defective water cooler storage type of 40 ltrs capacityincluding transportation to workshop and backfor thorough checking/including all accessories and components re-assembling the same after repair/ replacement of defective accessories/components including testing complete all as specified and as directed.Notes :- (a) New accessories/ components required shall be measured and paid separately, labour charges for fixing are deemed to be included in the unit rate.(b) Repair of body overhauling/repair, sealed compressor unit gas charging, painting etc shall be measured and paid separately. 42 All as per item No. 41 here-in-above for water cooler storage type 80 ltrs capacity complete all as specified and as directed. 43 All as per item No. 41 here-in-above but for water cooler storage type 120 ltrs capacity complete all as specified and as directed. 44 Supply only the following suitable accessories of water cooler (Make -Shreeram/ BLUE STAR /Usha/Voltas) :- 45 Condensor coil for water cooler 40 ltrs capacity of similar specification as of old one complete all as specified and as directed. 46 All as per item No. 45 here-in-above but water cooler of 80 ltrs capacity complete all as specified and as directed. 47 All as per item No. 45 here-in-above but water cooler of capacity 120 ltrs complete all as specified and as directed. 48 Aluminium fan blade for blower motor for water cooler of capacity 40/80/120 ltrs complete all as specified and as directed. 49 Wiring set complete consisting of PVC insulated cable wiring stranded copper conductor connecting clips etc suitable for water cooler 40/80/120 ltrs complete all as specified and as directed. 50 Thermostat including plastic regulating knob as per existing for water cooler of cooling capacity 40/80/120 ltrs complete all as specified and as directed. 51 Relay for water cooler type suitable for water cooler storage cooling capacity 40/80 ltrs/hrs complete all as specified and as directed. 52 Relay for water cooler type suitable for water cooler storage cooling capacity 60/120 ltrs/hrs complete all as specified and as directed. 53 Self closing bib tap/push tap 15mm dia chromium plated steel suitable for water cooler 40/80/150/120 ltr/hrs capacity complete all as specified and as directed. 54 PVC connection pipe high density 15mm dia 300mm long including jublee clamps for inner connection from tank outlet to tap complete all as specified and as directed. 55 15 mm dia PVC connection pipe 450 mm long complete with PVC union at both end complete all as specified and as directed. 56 15 mmbore Stop cock brass both end screwed complete all as specified and as directed. 57 15 mm dia Float valve/Ball valves high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete with all accessories complete all as specified and as directed. 58 Running Capacitor 10/15 mfd 230 volts AC, 50 Hz suitable for water cooler complete all as specified and as directed. 59 Starting Capacitor 40/60 mfd, 230 volts complete all as specified and as directed. 60 Supply and fix Copper pipe 3/8 complete all as specified and as directed. 61 Supply and fix Copper pipe 1/4 complete all as specified and as directed. 62 Supply and fix Copper pipe 3/16 complete all as specified and as directed. 63 Supply only new compressor suitable for 40/80 ltr/hrs storage capacity including testing complete all as specified and as directed. Note: Recharging of gas will be measured and paid separately. 64 All as per item No. 63 here-in-above but compressor of water cooler of storage capacity 40/40 ltrs/hrs complete all as specified and as directed. 65 All as per item No. 63 here-in-above but compressor of water cooler of storage capacity 60/120 ltrs/hrs complete all as specified and as directed. 66 Taking out old burnt condenser fan motor and supply and fixing of new blower motor and testingsuitable for water coolerany make or type complete all as specified and as directed. 67 DEEP FREEZERDismantling of defective deep freezer/ visi cooler including transportation to workshop and back of any capacity, sizeand type for thorough checking of all accessories and components re-assembling the same after repair/ replacement of defective accessories/components including testing complete all as specified and as directed.Notes:- (a) New accessories/ components required shall be measured and paid separately, labour charges for fixing are deemed to be included in the unit rate.(b)Sealed compressor unit, gas charging, painting etc shall be measured and paid separately. 68 Supply only new deep fridgecompressor for storage capacity of 300 ltrs deep freezer including testingall as specified and directed . Note: Re-charging of gas will be measured and paid separately. 69 Supply only new deep fridge /visi cooler compressor for storage capacity of 400 ltrs (or higher) deep freezer/ visi cooler including testingall as specified and directed. Note: Re-charging of gas will be measured and paid separately. 70 Supply only the following suitable accessories of deep freedge/ visi cooler of any make and capacity:- 71 Relay for deep freezer/visi cooler of any size/capacity complete all as specified and as directed. 72 Thermostate for deep freezer/visi cooler complete all as specified and as directed. 73 4 condenser fan motor 240 volt complete all as specified and as directed. 74 WINDOW TYPE ACScrapping out old surface of window type AC of capacity 1.5 TR/2 TRfor spray painting and applying one coat of synthetic enamel spray painting with 1st grade quality of existing colour complete all as specified and as directed. 75 Dismantling all electrical connection from the unserviceable compressor unit and disconnecting gas line and taking out burned compressor of capacity 2 TR and supply and install new compressor 2 TR, 230 V, 50 Hz suitable for window AC as per existing specification , mounting pad , nut and bolt and reassembling all the connection including testing complete all as specified and as directed. Note: Re-charring of gas will be measured and paid separately. 76 All as per item No. 75 here-in-above for compressor of capacity 1.5 TR complete all as specified and as directed. 77 Charging of refrigerant gas (R-22/R-410)forSplit/window type AC of capacity 1.5 TR only after vacuuming dehydration, leak testing of the system as per standard testing practicefor proper cooling effects and satisfactory performance complete all as specified and as directed. Note: Refrigerant gas R-22 will be measured and paid separately. 78 All as per item No. 77 here-in-above but for window type AC of capacity 2.0 TR complete all as specified and as directed. 79 Supply only the following suitable accessories ofwindow type ACof any make and capacity :-. 80 Starting capacitor 60/40 Mfd complete all as specified and as directed. 81 Starting capacitor 80/100 Mfd complete all as specified and as directed. 82 M&L for replacement to inverter type PCB for outdoor unit of split AC of capacity 1.5/2.0 TR including making connection for any make complete all as specified and as directed. 83 M&L for replacement toinverter type PCB for indoor unit of split AC of capacity 1.5/2.0 TR including making connection for any make complete all as specified and as directed. 84 Selector switch complete all as specified and as directed. 85 Thermostate switch complete all as specified and as directed. 86 Cooling coil sensor complete all as specified and as directed. 87 M&L for replacement ofPCB of window AC of 1.5/2.0 TR capacity and make complete all as specified and as directed. 88 Supply and fix swing motor for indoor unit complete all as specified and as directed. 89 Supply and charging of Gas R-22 or equivalent to Split/Window type AC machine including necessary arrangement for charging gas includingpressure testing complete all as specified and as directed. 90 Supply and charging of Gas R-410 or equivalent to Split/Window type AC machine including necessary arrangement for charging gas includingpressure testing complete all as specified and as directed. 91 Taking out old burnt blower motor double shaft and supply and fixing ofblower motor and testingsuitable for window type AC of any make/any type complete all as specified and as directed. 92 M&L for cutting through brick wall built in cement mortar forwindow type AC of any size /capacity and making good with cement mortar 1:4 including three coat of white washing on new plastered surfaceincluding preparation of surface complete to match with existing complete all as specified and as directed. 93 PVC Front grill suitable for Window AC of suitable size for 1.5/2 TR complete all as specified and as directed. 94 VOLTAGE STABILIZERSupply and fix voltage stabilizer 5 KVA capacity single phase, 240 volts after taking down old one 50 Hz input voltage 170 to 220 volts including necessary nuts, bolts, wires 1.5 to 2.0 TR etc complete all as specified and as directed. 95 All as per item No. 87 above but for Air Conditioner upto 1.5 TR complete all as specified and as directed. 96 Supply only cable connector 3 way suitable for connection of stabilizer with brass screw of different size complete all as specified and as directed. 97 SPLIT ACDismantling all electrical connection from the unserviceable compressor unit and disconnect gas line and taking out burned compressor of capacity 2 TR including transportation to workshop and back and supply & install new compressor (Rotary/Reciprocating)2 TR 230 V, 50 Hz suitable for split AC, mounting pad nut and bolt and reassembling all the connection including testing complete all as specified and as directed. Note: Re-charring of gas will be measured and paid separately. 98 All as per item no 90 here-in-before but 1.5 TR capacity complete all as specified and as directed. 99 Dismantling all electrical connection from the blower motor and taking out unserviceable burnt blower motor from outdoor unit and supply and install blower motor suitable for 2/1.5 TR split AC and reassembling all the connection in its original location and testing complete all as specified and as directed. 100 Supply and fixing remote control assembly with control circuit or connected wire suitable for 2 TR/1.5 TR split type AC complete all as specified and as directed. 101 Supply and fix swing motor (Synchronous motor) AC 220 Volt, 50/60 Hz for split type AC including necessary connection wire after taking out old one complete all as specified and as directed. 102 Dismantling all electrical connection and taking out outdoor unit of split AC after disconnect suction & liquid line and repair, cleaning, servicing and overhauling of the same including Air filter, blower motor (outdoor) andadjusting of remote control and checking all electrical devices including fixing cable socket/gland etc and reassembling and fixing in position and leakage check the unit, charging refrigerant gas as required in the system complete all as specified and as directed. Notes:- (a)Spares required for repair and gas shall be paid separately.(b) Contractor shall attendany type of complaint as and when required and no extra payment on this account shall be allowed. 103 All as per item No 95 here in above but for indoor unit of split AC complete all as specified and as directed. 104 Supply only the following spares for split type AC machine as per existing specification including removing unserviceable old spares complete all as specified and as directed. 105 AC contactor relay for split AC of any make complete all as specified and as directed. 106 Starting relay for 1.5/2.00 TR split AC complete all as specified and as directed. 107 Capilary tube of size 0.45 complete all as specified and as directed. 108 Capilary tube of size 0.55 complete all as specified and as directed. 109 Copper pipe 1/2 for liquid line including fittings complete all as specified and as directed. 110 Copper pipe 5/8 for suction line including fittings complete all as specified and as directed. 111 Copper pipe 1/4 for liquid line including fittings complete all as specified and as directed. 112 Copper pipe 3/8 for suction line including fittings complete all as specified and as directed. 113 PVC Fan blade suitable for outdoor condenser unit including necessary brass nut bolt etc complete all as specified and as directed. 114 Running capacitor 50/2 mfd series 8 pole complete all as specified and as directed. 115 Running capacitor 50/6 mfd series 9 pole complete all as specified and as directed. 116 Supply and fix PVC insulated four core copper flexible wire of size 2.50 sqmm 1100 volts grade including taking out old one complete all as specified and as directed. 117 Reversible valve for AC complete all as specified and as directed. 118 Supply and fix PVC insulated three core copper flexible wire of size 2.50 sqmm 1100 volts grade including taking out old one complete all as specified and as directed. 119 Supply and fix PVC flexible pipe 25 mm dia for cable protection including necessary clamps, screw etc complete all as specified and as directed. 120 Supply and fix PVC drain pipe 25 mm dia suitable for spilt AC with necessary saddle screws complete all as specified and as directed. 121 Supply and fix outdoor unit condenser coil for Split AC 1.5 TR capacity complete all as specified and as directed. 122 Supply and fix outdoor unit condencer coil for Split AC 2.0 TR capacity complete all as specified and as directed. 123 Supply and fix air filter for Split AC of any size and make complete all as specified and as directed. 124 Supply and fix liquid sensor for Split AC 1.5/2.0 TR capacity complete all as specified and as directed. 125 Supply and fix Air sensor for Split AC 1.5/2.0 TR capacity complete all as specified and as directed. 126 Supply and fix Compressor leg bush of any size for 1.5/2.0 TR capacity complete all as specified and as directed. 127 Supply and fix insulation foam for copper pipe complete all as specified and as directed. 128 Taking down old unserviceable remote control assembly and dismantling the unit and replaced the unserviceable item such as PCB, transformer and magnetic coil suitable for out door split AC and reassembling the same including testing complete all as specified and as directed. 129 Supply and fix factory made AC stand made out of angle ,flat etc. includingfixing in wall with, nuts and bolts complete all as specified and as directed. 130 Supply and fix outdoor unit of Split AC 2.0 TR with all accessories (compressor, wiring, copper pipes ) including fixing to Wall or floor complete all as specified and as directed. 131 Supply and fix outdoor unit of Split AC 1.5 TR with all accessories (compressor, wiring, copper pipes ) including fixing to Wall or floor complete all as specified and as directed. 132 Supply and fix indoor unit of Split AC 2.0 TR with all accessories (cabinet, wiring, copper pipes, remote control ) including fixing to wall or floor complete all as specified and as directed. 133 Supply and fix indoor unit of Split AC 1.5 TR with all accessories (cabinet, wiring, copper pipes, remote control ) including fixing to wall or floor complete all as specified and as directed. 134 Supply and filling refrigeration Gas R-32 complete all as specified and as directed. 135 Supply & Fix over replacement double door metalplug & socket DB complete all as specified and as directed. 136 CASSETTE TYPE ACDismantling all electrical connection from the unserviceable compressor unit and disconnect gas line and taking out burnt compressor of capacity 4 TR and supply and install new compressor 4 TR 230 V, 50 Hz suitable for cassette type AC, mounting pad nut and bolt and reassembling all the connection in itsoriginal location and testing complete all as specified and as directed.Notes: (a)Recharging of gas will be measured and paid separately.(b) New accessories/ components required shall be measured and paid separately, labour charges for fixing are deemed to be included in the unit rate. 137 Supply only water drain motor complete all as specified and as directed. 138 Supply only blower motor for outdoor unit complete all as specified and as directed. 139 Supply only blower motor for indoor unit complete all as specified and as directed. 140 Supply only cooling coil sensor complete all as specified and as directed. 141 M&L for replacement of PCB board for indoor/outdoor unit ofcassette type/ package typeAC after dismantling old one complete all as specified and as directed. 142 Supply and fix MNX 25, 3 phase contactor for out door unit complete all as specified and as directed.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 14-10-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 21-10-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 70000.0 /-
Tender Value
INR 35 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Notice 0 KB
Click here to download tender document Tender Document 0 KB
Click here to download tender document Tender Document 0 KB
Click here to download tender document Tender Document 0 KB
Click here to download tender document Tender Document 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail