}

Tender For Additional / Alternator To Bldg No P-132 Of 501 Asc Bn At Patiala Mil Stn, patiala-Punjab

Statutory Bodies & Commissions/Committees has published Tender For Additional / Alternator To Bldg No P-132 Of 501 Asc Bn At Patiala Mil Stn. Submission Date for this Tender is 30-10-2024. Uniform Tenders in patiala Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

45359591
Corrigendum : Tender For Additional / Alternator To Bldg No P-132 Of 501 Asc Bn At Patiala Mil Stn
Open Tender
Indian
Punjab
Patiala
30-10-2024

Tender Documents

Tender Details

Tender For Additional / Alternator To Bldg No P-132 Of 501 Asc Bn At Patiala Mil Stn; 1 Taking down cement plaster of any description, any thickness from external surfaces of walls/soffits etc. incl raking out joints, hacking for keys, scrubbibg down with water etc complete all as specified and directed by Engineer-in-Charge. 2 M&L for cement plastering 15mm thick in cement mortar 1:4 including mixing of liquid water proofing compound as per manufacturers instructions on brick work or concrete surfaces or in chajjas/parapet walls etc finished even and smooth without using extra cement complete all as specified and as directed by Engineer-in-Charge. 3 Supply only integral liquid water proofing compound complete all as specified & as directed by Engineer-in-Charge. 4 M&L for cement plastering 10mm thick in cemet mortar 1:6 on brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed by Engineer-in-Charge. 5 M&L for cement plastering 5mm thick in cemet mortar 1:3 as on ceilings or concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed by Engineer-in-Charge. 6 Complete removal of existing treatment of any type/description from walls/RCC surfaces etc with mechanical means/grinder complete all as specified and directed. 7 Complete removal of existing treatment of any type/description from ceilings/RCC surfaces etc with mechanical means/grinder complete all as specified and directed. 8 M&L for Applying two coats of oil bound distamper white or tinted over a coat of primer on walls incl one coat of primer over & incl preparation of plastered finished of wall specified and directed by Engineer-in-charge. 9 M & L for preparation of newly plastered surfaces of ceiling and applying three coats of white wash, complete all as specified and directed by Engineer-in-Charge. 10 M & L for Preparation of plastered surfaces of wallsand applyingtwo coats of cement base paint over a coat of primer , complete all as specified and directed by Engineer-in-Charge. 11 Taking down chowkhats or frames (without taking off shutters from the frame) exc 1.5 Sqm and n. exc 4.00 Sqm incl cutting holesand making good reqd shape for hold fast block for new frame complete all as specified. 12 Taking down chowkhats or frames (without taking off shutters from the frame) n. exc 1.5 Sqmincl cutting holesand making good reqd shape for hold fast block for new frame complete all as specified. 13 S&F Powder coated Pressed steel frames made of MS sheet of 1.20 mm thickness for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etccomplete all as specified,size 105x60mm. 14 S&F Powder coated Pressed steel frames made of MS sheet of 1.20 mm thickness for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc,complete all as specified,size 125x60mm. 15 M&L PCC (1:3:6) type C-0 using 12.50mm graded aggregate as infilling in PS chowkhats all as specified. 16 S&F factory made flush shutters 35 mm thick, solid core construction, with particle board core and plywood face panels, commercial type on both sides with both faces are covered with decorative face veneer with 6mm thick lipping frame to match including supply and fixing following items :(a) Stainless Steel (304 Grade) Finished Butt Hinges 150mm -4 nos per leaf(b) Stainless Steel (304 Grade) Finished Tower Bolt 200mm long - 2 nos per leaf(c) Stainless Steel (304 Grade) Finished Handles 200 mm - 2 nos per leaf(d) Stainless Steel (304 Grade) Finished Sliding Door Bolt/Aldrop 16x250mm- 1 nos per leaf(e) Stainless Steel (304 Grade) Finished Floor Door Stooper- 1 nos per leaf 17 S&F 35mm thick glazed and skelton shutters of 2nd class hard wood (factory made) open rebated and divided to receive glass, gauze etc (with sash bars) edges of framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass etc size of members of shutter as specified in SSR-91 Pt-1 section 8 clause 8.20(a), kiln seasoned and chemically pressure treated all as specified including stainless steel 304 Grade wire cloth (wire dia. 0.22mm) and the supply and fixing following items:(a) Stainless Steel (304 Grade) Finished Butt Hinges 150mm -4 nos per leaf(b) Stainless Steel (304 Grade) Finished Tower Bolt 200mm long - 2 nos per leaf(c) Stainless Steel (304 Grade) Finished Handles 200 mm - 2 nos per leaf(d) Stainless Steel (304 Grade) Finished Sliding Door Bolt/Aldrop 16x300mm- 1 nos per leaf 18 S&F 300mm, mild steel ordinary rat tail rod pattern springs including roller and roller plate complete fixed all as specified. 19 S & F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, in openingcomplete all as specified and directed by Engineer-in-Charge. 20 S & F Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails. M S frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheet for top rail, lock rail & bottom rail on either side and as gap insert for top rail & bottom rail; Paneling of plain colour PVC sheet to be fitted in the MS frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joining together with solvent cement, supplying & fixing in the frame at site as per specification & drawing along with necessary aluminium mongaries for fixing of door,complete all as specified and directed by Engineer-in-Charge.(a) Stainless Steel (304 Grade) Butt Hinges 150mm -3 nos per leaf(b) Aluminium Tower Bolt 150mm long - 2 nos per leaf(c) Aluminium Handles 150 mm - 2 nos per leaf 21 S&FPPGI windows & ventilators 1.25 mm sheet thickness incl standard accessories,EDPM gasket, but excluding glazing,wire mesh etc complete all as specified and directed (sheet glass and wire cloth to measured and paid separately). 22 Supply only sheet glass ordinary quality 4mm thick area n.exc 0.50 sqm each. 23 Supply only stainless steel wire cloth 0.36mm nominal dia of wire and 1.40mm avg width of apreture. 24 Demolition of cement concreteun -reinforced in ground floors and pavings n.exc 15cm thicknesscomplete all as specified. 25 Dismantling, floor, hearth or wall tiling including CM(bedding (but not backing), removing serviceable tiles to store & rubbish off the premises 26 M&L for Glazed ceramic tiles 200x300x7mm thick coloured on vertical surfaces set and jointed in neat cement slurry and pointed in white cement to match including 10mm thick rendering of CM 1:4 all as specified and directed. 27 M&L forNon skid ceramic (coloured tiles) of size 400x400x7mm thick in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match includingscreed bed 15mm thick in CM 1:4 all as specified and directed. 28 M&L for Baroda Green marble,machine cut as in shelves/steps/cills/jambs/skirting/border only in tile flooring and the like works and flooring etc,20mm thick including bull nose the front length,set and jointed in cement slurry over & including screed of 15mm thick rendering in cement mortar (1:4) and pointed in cement mortar mixed with pigment to match the shade of slab including rubbing,cutting and mirror type granite polishing complete all as specified.Note: Single piece should be used in steps/cills/jambs/shelves. 29 M&L for un-polished kota stone slabs of sizes not less than 600x1800mm ,fixed in position as per required size , machine cut as in shelves/partitions of cupboards and the like works,20mm thick including bull-nose the front length,set and jointed in cement mortar (1:4) and complete fixed in position complete all as specified.Note: Single piece should be used in shelves/partitions of cupboards. 30 Machine cut Kota stone slab as in flooring of size 580x580 mm each 20-22 mm thick,set and jointed in cement slurry including border of 100mm wide baroda green marble as per pattern approved over & including screed of 20 mm thick in CM (1:4) and pointed in cement mixed with pigment to match the shade of slab including rubbing,cutting and mirror type granite polishing complete all as specified. Note :1.All the edges of slabs shall be grinded/cutted at the right angle before laying,so that paper thin,smooth jointing to be obtained.2.The colour of the slabs shall be uniform. 31 S&F stainless steel tubing of 20mm bore minimum 1mm wall thickness as in curtain rod complete incl supply and fixing of accessories like brackets,stops etc all as specified & directed.(for the purpose of measurement and payment running length of curtain rod only shall be considered.) 32 S&F vitreous china wash hand basin white, flat back, size 450x300 mm including 32 mm CP brass waste fitting,45cm long PVC connection with brass nut at both ends,32mm dia PVC waste pipe MS angle iron brackets and making good disturbed surfaces in CM 1:3 or PCC 1:2:4 complete all as specified. 33 S&F vitreous china wash down water closet pan floor mounting (pedestal pattern/EWC) P trap white/ivory including connection to drain (or out going pipe) and to flushing pipe,antisyphonagee pipe,etc,with flush pipe CP 32mm dia and incl plastic seat cover,complete all as specified and directed. 34 S&F vitreous china Orissa Pan water closet white colour of size 580X440mm white with (C I P trap long size) joint run and lead front or back inlet with integral footrest including connection to trap and to flushing pipe,anti-syphonage pipe etc , fixed in repair complete and making good to floor in CM 1:3 all as directed and specified. 35 S&F flushing cistern of PVC 10 ltr. cap. with dual flushing system, valveless syphonic action type, , low level, white/ivory/off white with inlet, ball valve, float and including brackets and connection to pipe etc. and incl all necessary accessories like rag bolts/gel gasket etc as recommended by manufacturer for fixing, packing and taking down existing of any description/size completeall as directed and specified. 36 S&F health faucet (ABS Body) with 1.25 metre long flexible tube and ABS wall hook including making connection and fixed in position completeall as directed and specified.Make: Hindware (Cat No-F160013) or equivalent from Parryware/Cera as approved by AO. 37 S&F 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board with aluminium frame all around hanging to wall with rawal plug and iron slits cup washers all as directed. 38 S&F soap dish.stainless steel of suitable size to accommodate soap,tooth brush and tooth paste complete all as directed and specified. 39 Taking up or down existing steel tubing and connection,15mm bore complete all as specified. 40 S&F 15mm bore steel water tubing medium grade galvanised with all fittings and fixed complete to walls and ceiling or laid in floor etc including taking down existing pipe complete all as specified. 41 Taking up or down existing steel tubing and connection,20mm bore complete all as specified. 42 S&F 20mm bore steel water tubing medium grade galvanised with all fittings and fixed complete to walls and ceiling or laid in floor etc including taking down existing pipe complete all as specified and directed. 43 S&F brass chromium plated overhead shower 125mm dia with 230mm long shower armincl all necessary accessories as recommended by manufacturer for fixing and taking down existing of any description/size complete in all respect complete all as specified and directed. 44 S&F 15mm bore Bib tap cast copper alloy fancy type CP with crutch or butterfly handle,screwed down screwed for iron pipe or for brass ferrule complete all as specified and directed. 45 S&F Pillar taps 15mm borecast copper alloy with capstan heads cromium plated screwed down high pressure with or without lettered HOT or COLD with long screwed for iron pipe and fixed complete all as specified and directed. 46 S&F Stop valves,15 mm borefancy type, CP with long shank and cup ( concealed type ), exposed part kit with wall flange and regular body of concealed stop cock suitable for 15mm line with protection cap fixed in position complete in all respect all as specified. 47 S&F 15 mm bore Angular Stop Cock with wall flange, fency type chromium plated cast copper alloy screwed down, high pressure, screwed one ends for 15mm bore of iron pipe or for union and fixed in position complete in all respect all as specified. 48 S&F 15 mm bore sink cock with wall flange,fency type chromium plated cast copper alloy screwed down,high pressure,screwed one ends for 15mm bore of iron pipe or for union and fixed in position complete in all respect all as specified. 49 S&F stainless steel sink with drainage board , AISI 304 quality grade,1mm thick ,glossy finish,for kitchen with plugs washers and CP waste coupling of 32mm dia and including cantilever angle iron brackets,connecting union etc,overall size 915mmx460/928mmx458mm with bowl size 410x355x185mm including CP bottle trap 32mm with 125mm and 175mm longwall connection pipe & wall flange and making good disturbed portion in CM 1:3 or PCC 1:2:4 complete all as directed. 50 S&F towel rod CP 60 cm long between flanges and including all accessories like brackets/screws etc as recommended by manufacturer and complete fixed in position complete all as specified. 51 S&F doubled layered rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top / cover) 500 Ltrs capacity hoisted and fixed in position all as specified including ball brass valves, high pressure, with polythene float and fly nut complete screwed for 20mm bore iron pipeincluding GI nipple/union of 20mm bore to connect GI tubing to PVC tank complete all as specified and directed. 52 S&F 25mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed in repair complete all as specified. 53 S&F 20mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed in repair complete all as specified. 54 S&F PVC connections 15mm size with brass nuts of length 450mm complete all asspecified and directed. 55 S&F stainless steel grating 150mmx150 mm size square shaped with cockroach trap for floor trap fixed in position complete all as specified . 56 M & L for Repair to RCC sunshades, Chajjas, Balconies, Columns, bands, beams and similar RCC work at any position/height by dismantling loose/disintegrated portion and dubbing out with Cement Concrete 1:1½:3, 15mm to 50mm thick using 6 to 12mm graded stone aggregate to make up and finished to required shape including provision of necessary supports if required and stitching of cracks with mild steel U clamps made out of 8mm dia @ 150mm c/c with inserting concrete block stretcherwith cement mortar 1:3 mixed with adhesive chemical (Polymer based) and reinforced with PVC chicken mesh including form work where ever required and finished with10 mm thick plastering in CM 1:4 finished even and fair without using extra cement including preparation of surfaces to receive finishes complete all as specified and directed. 57 Dismantling of Stone slabs & tiles of any description or thickness in floors, aprons etc. Laid, bedded & pointed in any mortar, complete all as specified and directed by Engineer-in-Charge. 58 S&F Mild steel framed work as in grills/guard bars shouldered/welded with steel window / ventilators frames complete all as specified. 59 M & L for plain cement concrete 1:7:12 mix, type E-2 (using 40mm graded Brick aggregate) as in filling of sunken portion complete all as specified and directed. 60 M & L for rendering 15 mm thick in cement mortar 1:3 , mixed with water proofing compound, on brick or concrete surfaces of wall of sunken portion , trowelled to even and smooth finish without using extra cement with WPC paid and measered sepretly complete all as specified. 61 M & L for applying three coats of water bond acrylic based cementitious material of approved quality for sunken portion treatment all as per manufacturer instruction and providing 200 mm micron thick polythene film over 85/25 grade bitumen layer laid@ 0.5 kg /Sqm complete all as specified. 62 S&F mild steel Bands,straps,supports or stays for rainwater ,ventilating pipes,including bolts,if required : hooks (stay) and similar small articlesall as specified. 63 S&F PVCSWR,100mm bore,single socketed in any length with rubber ring joints using solvent as per manufacture instruction,fixed to walls complete all as specified including fixing of pipe to wall with flat iron clamps of size 25x3mm , bolts washing , nuts etec as in repairs after taking down existing damaged CI rain water pipe complete all as specified and as directed . 64 S & F PVC (SWR) bends/tees of any radius for 110mm bore with access door as in repair complete all as specified. 65 S&F cast iron soil, waste and vent pipe,100 mm bore, sand castin any length, with or without ears, with lead joints,fixed to walls/laid in floors and making necessaryconnections,fixed as in repair complete all as specified and directed. 66 S&F cast iron soil, waste and vent pipe,75 mm bore, sand castin any length, with or without ears, with lead joints,fixed to walls/laid in floors and making necessaryconnections,fixed as in repair complete all as specified and directed. 67 M&L cast iron nahani/floor/multifloor trap 100 mm dia including jointing with solvent cement in repair fixed in cement concrete (1:2:4) type B1 cmplete all as specified and directed. 68 S&F CI bends (any radius),for 100mm bore CI pipes diminishing pieces or tapers (large bore measured) fitted with oval access doors complete all as specified. 69 S&F single Y-shaped CI junction pieces,ordinary or inverted(spigot or socket type) for 100mm bore pipes complete all as specified. 70 S&F cast iron junction combination T equal or unequal for 100mm bore with access door as in repair complete all as specified. 71 M&L for cast iron cowls of 100mm bore complete all as specified and directed. 72 Salt glazed stone-ware gully traps,centrifugal type 150mmx150 mm size,square or round mouthed ,type P or S incl CI grating fixed in repair complete all as directed and specified. 73 Dismantling of brick tiles or terracing tiles single layers on roofs complete all as specified. 74 Dismantling mud phuska on roof and removing debris away from site. 75 Roughening surfaces of oil concrete floor/roof by picking, sweeping cleaning and washing down with water to remove dust,etc.complete all as specified and as directed. 76 PCC 1:2:4 type B-0 using 12.5mm graded stone aggregates as in padding over roof,minimum thickness at khurra as 20mm to maintain a slope of 1:100,complete all as specified and directed. 77 Cutting grooves in brick wall,75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specified. 78 Provding and laying 3mm thick APP (Atactic Polyproplene Polymer) modified prefabricated five layer, weighing 3kg/sqm water proofing membrane black finished,reinforced with non-woven polyster matt make as approved includinga coat of bitumin primer @ 0.40 Ltr/Sqm of the samemembrane manufacturer ofdensity 0.87 to 0.89 Kg/Ltr at 25 degree C temperature and viscosity 70 - 160 cps Over the coat, thelayer of membrane shall be laid using butane torch and sealling alljoints etccomplete as per standard practice as per manufacturers instructions.The vital physical and chemical parameters of the membrane shall be as under - (i) joint strength in longitudinal and transverse direction at 23 degree C as 650/450N/5cms(ii) Tear strength in longitudinal and transverse direction as 300 / 250 N/5 cms.Softening point of membrane not less than 150 degreeC Cold flexibility upto 20 degree C when tested in accordance with ASTM (D05147) (iii)Thelaying of membrane shall be gotdone through the authorised applicator of manufacturer of membrane only all as specified and directed by Engr-in-charge. 79 Preparation of new steel surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified. 80 Preparation of new wood surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified. 81 Demolition of reinforced cement concrete of any description and in water storage tank of any size/description/position located on terrace of the building including moving the demolition material to low lying area or out of defence land all as specified and directed. 82 Taking down of PVC water storage tank of any size/description/position located on terrace of the building all as specified and directed. 83 Demolition of brick work or stone/boulder masonary built in cement mortor including all quoins,arches,pillars etc complete all as specified. 84 M&L Brick work with sub class B bricks straight or curved on plan exceeding 6m mean raidus bulit in C:M 1:6 all as specified. 85 M & L for Cement concrete (1:3:6) type C-1 using 20mm graded stone aggregate as in plinth protection, 50 mm thick, surfaces finished even and smooth without using extra cement as in plinth protection including provision of construction joints complete all as directed by Engr-in-Charge and complete as specified. 86 M & L for PCC 1:3:6 type C-2 using 40mm graded stone aggretgate, as in base for PVC tanks complete all as specified and directed. 87 M&L for 100mm thick cement concrete1:4:8 type D-2 in sub base to flooring etc complete all as specified. 88 Demolition ofcement concrete of any description and in any position not otherwise specifically provided for complete all as specified. 89 M&L Precast cement concrete type B1 (1:2:4) using 20 mm graded aggregate set in CM (1:4) in cover slabs for manholes etc.duly embossed MES MONTH & YEAR of casting including necessary formwork all as directed . 90 TMT bars 6 to 8mm dia cut to length,bent to shape required including cranking,bending spirally hoping for coloumns,hooking ends and binding with mild steel wire not less than 0.9 mm dia complete all as specified. 91 Supply and apply of rust remover cum passivator by brush in two coats @ 0.3kg/m2/2coat of density:1.01 kg/I at 30C complete all as per manufacturers instructions and all as specified.Note:The application of rust removal shall be got done through the authorised applicator of manufacturer of membrane only all as specified and directed.Make: Sika , Dr Fixit , RIO Industries 92 Supply and apply cementitious coating for corrosion protection having a cement base polymer modified rebar corrosion protection system by applying the first coat approx 1mm thick layer of product carbonation resistance 2mm of sikatop ArmatecR -108 or equivalent as specified corresponds to 20 mm of normal mortar;bond strength 1N/mm2 according to ASTM C 882-78 applying @ 4kg/m2 for two coats onto the prepared reinforcing steel with a medium-stiff brush.it is unavoidable that specified product will also be applied in the same way after a waiting time of 2-3 hours (+20C) complete all as per manufacturers instructions and all as specified.Note: The application of cementitious coating for corrosion protection shall be got done through the authorised applicator of manufacturer of membrane only all as specified and directed.Make: Sika , Dr Fixit , RIO Industries 93 Providing ,mixing & applying two components Epoxy resin concrete bonding coat on prepared RCC surfaces as per manufacturers apecification incl prepration of surface by chipping and throughly cleaning of surface complete wherever required and as per directions of Engineer-in-charge.Consumption: o.5 kg/m2 complete all as per manufacturers instructions and all as specified.Product requirements : complies with ASTM C 881 Type II Grade 2 class B+C.Note: The application of epoxy bonding primer shall be got done through the authorised applicator of manufactureronly all as specified and directed.Make: Sika , Dr Fixit , RIO Industries 94 Supply and apply a pre-batched one component polymer modifies cementitious patch repair mortar in 25mm thickness.Yield:approx 0.84 ltr/kg.System requirements:compressive strength =50 N/mm2 (28 days)according to ASTM C 109 : flexural strength = 3 N/mm2 (7 days)according to ASTM C 293-79consumption of 2.1 kg/sqm/mmNote: The applicator of polymer repair mortar shall be got done through the authorised applicator of manufacturer of membrane only all as specified and directed.Make: Sika , Dr Fixit , RIO Industries 95 S & F Factory made pre-laminated PVC solid board 18-20mm thick pre-laminated both sides with wooden finished on one side and white finished laminated on other side as in cup-board front shutters complete fixed in position in all respect all as specified and including supply and fixing of following items:-(a) Stainless Steel (304 Grade) Finished tower bolt 200mm long -1 nos per leaf(b) Stainless Steel (304 Grade) FinishedHandles200mm - 1 nos per leaf(c) Stainless Steel (304 Grade) Finished magnectic catchers0 mm - 2 nos per leaf 96 S&F pre-laminated PVC solid board as in frames for cupboards shutters 75mm wide 40mm thick (doubled sandwiched of 20mm) prelaminated on one side with wooden finished complete fixed in position in all respect all as specified. 97 S&F continuous (piano) hinges,stainless steel 304 grade finished,and fixed (size of hinges in 30mm )complete all as specified. 98 Supplying and Applying two component elastomeric acrylic polymer modified cementitous waterproofing coating smartcare Damp block 2k or approved equivalent, having 100 % elongation as per ASTM D412 resisting 5 bars hydrostatic pressure as per DIN 1048, reduction to rapid chloride shall br 70 as per DIN 1048 crack bridging upto 1.2 mm as per ASTM 4548.5. The coating shall have food grade certificate from laboratories like CFTRI. The mixing ratio of the coating shall be 2 parts of powder & 1 part of liquid without any water addition in the mixing etc. complete as per manufacturer specifications. 99 Takingdown carefully existing points wiring on surface conduit/concealed conduit including conduit from surface and expect conduit in concealed wiring for light/fan/socket/power/bell from wall & roof along with fitting and fixtures such as switches, sockets, ceiling roses, batten holders, unserviceable light fittings, pieces of wires, gutties, conduit, wooden boards etcremoving materials to store for keeping in safe custody of contractor for which the credit has been considered under schedule of creditand making good the disturbed portion of all floor, ceiling etc all as specified and directed. 100 M & L for Point wiring with 1.5 sqmm PVC insulated and unsheathed FRLSH single core multistranded copper conductor for one light/fan/bell point in and including NEW PVC rigid non metallic concealed conduit 19/20 mm dia, medium duty, ISI Marked to be terminated in pressed steel terminal boxes with PVC modular top cover plates of suitable size for mounting of modular type switches/sockets/regulators including 1.5 sqmm PVC insulated and unsheathed FRLSH single core multistranded copper earth continuity conductor controlled by one switch and/or one regulator complete including cutting chases and making good the surfaces in CM 1:3 and finishing the surface as per existing treatment all as specified and directed by Engr-in-charge.Notes: (i) Cost of Pressed steel Terminal Boxes and modular Top cover plate shall be included in point wiring. (ii) Wiring shall be done as per colour code in IS for phase, neutral and earth.(iii)-Cost of Eye/bottle thimblesused for connection in switches/sockets & MCBs in DBs shall deemed to be included in the unit rate quoted for this item. 101 M & L for point wiring with 1.5 sqmm PVC insulated and unsheathed FRLSH single core multi-stranded copper conductor for one light point controlled by 2 way and including PVC rigid concealed conduit medium grade 19/20 mm dia to be terminated in pressed steel terminal boxes with top cover plateincluding 1.5 sqmmPVC insulated and unsheathed FRLSH single core multi-stranded copper earth continuity conductor controlled by one switch and/or one regulator complete including repairing the surfaces in CM 1:3 and finishing the surface as per existing treatment all as specified and directed. Notes: (i) Cost of Pressed steel Terminal Boxes and modular Top cover plate shall be included in point wiring. (ii) Wiring shall be done as per colour code in IS for phase, neutral and earth. (iii)-Cost of Eye/bottle thimblesused for connection in switches/sockets & MCBs in DBs shall deemed to be included in the unit rate quoted for this item. 102 All as per Sl item No 100.00 above herein before but one socket out let 5 pins 5 Amp on the same board with other switches complete all as specified and directed. 103 All as per Sl item No 100.00 above herein before but for one socket out let 5 pins 5 Amp on independent board complete all as specified and directed. 104 All as per item No.100.00 herein beforebut 2.5 Sqmm PVC insulated and unsheathed FRLSH single core multistranded copper conductor incl 2.5 Sqmm PVC insulated and unsheathed FRLSHcopperearth wire for switch socket combination 3 pin 15 amps on independent board. 105 S&FModularswitch1 way, 6 Amps, 1 module, 230 volts complete all as specified. 106 S&FModularswitch2 way, 6 Amps, 1 module, 230 volts complete all as specified. 107 S&FModularswitch1 way, 16 Amps, 1 module, 230 volts complete all as specified. 108 S&FModularbell push switch1 way, 6 Amps, 1 module complete all as specified. 109 S&F Supply & fix in replacement of Call bell ding dong AC 230 volt single pole complete all as specified. 110 S&FModular socket 5 pin 6 Amps, 2 module 230 volts complete all as specified. 111 S&FModularsocket 5 pin 6 &16 Amps, combination type2 module complete all as specified. 112 S&FModular Fan regulator step type, 120 watts, 2 module complete fixed as in repair all as specified. 113 S&F ceiling rose surface bakelite surface 65 x 50mm3 terminals all as specified & directed 114 S&F Lamp holder including LED bulb 9 W including flexible wire 0.5 Sqmm copper cable all as specified & directed by Engr-in-charge. 115 S&F New generation energy saving and environmental friendly long life LED building security light 1x25 watts made up of pressure die cast alluminium housing with high power LED as light source and lense embedded PC cover having TOP OPENING separate driver compartment with IP65 protection and impact resistance of IK07,with all accessories including suitable bracket with 20 mm bore light grade GI pipe bemd to shape, including MS clamp of size of required size and PVC cable 1.5 Sqmm twincore from ceiling rose to light fittings complete all as specified and directed by Engineer-in-charge. 116 S&F Surface Mounted LED Bulk Head Luminaire of capacity 10 watt with ABS Body & Polycarbonate Diffuser, IP54 inc connection with ,with flexible wire 0.5 sqmm copper cable all as specified & directed by Engr-in-charge. 117 S&F Sub main wiring with two single core 6.0 Sqmm PVC insulated and unsheathed FRLSH,stranded copper conductor cable drawn through PVC concealed conduit 25 mm dia including 6.0 Sqmm PVC insulated unsheathed FRLSH stranded copper conductor cable as earth wire all as specified and directed by Engineer-in-charge. Note 1:- 2(two) Runs of 6.00 Sqmm Copper conductor cable, 1 Run of PVC conduit & 1 Run of 6.00 Sqm Copper conductor Earth wire shall be measured as one unit)Note 2 :(i) Rate quoted for this items shall be inclusive of the cost of (i) Rigid non-metallic PVC conduit of 25 mm dia with tees, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc.(ii) Cutting chases, pinning in making good to facing where required and pointing in cement mortar 1:3 to match the existing surfaces and cutting not exc.10 cm girth . (iii) Including taking out/down existing unserviceable sub main wiring.(iv) Cost of PVC conduit is included in unit rate quoted by contractor. 118 S & F MCCB, 4 Pole, 100 A, 25 KA for fixing in DB including proper thimble connection, thermal and magnetic release protectioncomplete all as specified and directed by Engineer-in-charge. 119 Supply and fix in replacement of epoxy power coated MCCBdistribution box double door VTPN 4 way vertical type AC 415 V with IP 43 protection for MCBs alongwith provision of MCCB as incomer with commen bus-bar at incoming end of outgoing MCBs grouted/ flush to wall, complete all as specified by Engineer-in-charge. (Note :- MCCB will be measured and paid under seperate item) (i) Cost of Eye/bottle thimblesused for connection MCBs in DBs shall deemed to be included in unit rate quoted for this items, (ii) Electric wiring should be done in proper colour coding i.e. Red for phase, Black for neutral and Green for Earth.(iii) connection of theMCCBs/ MCBs with cableshall be made through appropriate size pin /bottle type thimble -properly crimped. all the vacant holes of the DB shall be provided with blank plates of appropriate size. 120 Supply and fix in replacement of Sheet metal enclosure 8 ways double door for DBs when MCBs areto be used 240,volts including 200 Amps standard bus bar of suitable size and common neutral link allflush mounting type, drilling holes for incoming and out going cables with IP43 protection complete all as specified & directed byEngr-in-charge. 121 MCB , SPN B curve, 240 Volts ,32-40 amp for fixing in DBs ofincluding proper thimble connections complete all as specified and directed by Engineer-in-Charge. 122 MCB, single pole C curve 240 volts 6 to 32 Amp capacity for fixing in DB’s including proper thimble connections complete all as specified and directed by Engineer-in-Charge. 123 M & L in replacement of UNSV Earthing complete with galvanized iron earth plate electrode of size 600x600x6.0mm , buried directly in ground (earth pit not less than 2.25 mtrs below normal ground level) with top edge of earth plate not less than 1.5 mtr below normal ground level, connected to galvanized earth lead wire 4.0 mm dia by means of bolts , nuts , check nuts and galvanized iron or steel including earth work in any type of soil, charcoal salt 15 cm around the earth plate 20 mm dia watering pipe medium grade 1.70 mtr long with a plug at top, GI protection pipe light grade 15 mm dia from earth pit to main board including PCC pit in cement concrete 1:2:4 along with CI frame and cover 10mm thick duly hinged to CI frame as shown in the electrical plate No3 of SSR 2009 part 1 specification at page 497. 124 S & F in replacement Tube light fitting Self Ballasted LED Batten. Extruded Thermoplastic body with PC Diffuser in squareLED Batten 18/20W 6500Kof capacity ,20 watt,4 ft long incl 3 core flexible wire 0.5 sqmm copper cable all as specified and directed by Engr-in-charge. 125 Supply and fix in replacement of elegatly designed sleek surface mounted pressure die-cast aluminiumLEDluminaire in powder coated white finish in round profile with optimized heat sink for efficient heat dissipation and independent electronic LED driver of capacity 12 W LED of 5000 K and making good the existing surface as per existingcomplete all as specified & directed. 126 Supply & fix Exhaust fan AC single phase 230/240 v of size 300 mm sweep 900 rpm metal body, high efficiency motor, dynamically balanced blade for better performance and corrosion-resistant powder coated metallic finish including Louvers, making holes for exhaust fan 300 mm sweep, grouting nut-bolts and make surface good complete all as specified and directedby Engineer-in-Charge. 127 XLPE Insulated ,screened, PVC bedded, galvanized steel wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4 core supplied& laid in replacement including connection with appropriate size of Al thimble complete all as specified & directedby Engineer-in-Charge. 128 Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for laying of cables including getting out in any kind of soil complete all as specified and directed. 129 Returning filling in including spreading, levelling, and well ramming, in layers not exceeding 25 cm each layer of any kind of soil. 130 Removing surplus excavated material from site not exceeding 50 mtrs from starting point and depositing where directed at level not exceeding1.5 mtr above the starting point. 131 Material and labour for sand cushioning for cables 8 cm below the cable and 15 cm abovewith dry river sand in trenches for cushioningof underground cable line including spreading, leveling, well ramming completed all as specified and directed. 132 Cutting of hardstanding floor/wall for laying of cable including matching with suface by using cement concrete all as specified and directed by Engr-in-charge. 133 M&L for Boring of holes under road, pavement, hard standing by trench-less technology using ultrasound technique and necessary machine suitable to pass through 40 to 80 mm boreGItubing and cable etc complete all as specified and directed.Note: GI pipe shall be measured and paid seperately under relevant item. 134 Supplying & laying factory made unreinforced Precast concrete cable coversclass LV type 1, flat, Size 250x150x40mm laid in trenches as protection to cables completeall as directed by Engr-in-Charge 135 Material and labour for replacement of GI tubing light grade 40 mm borefor passing through cables under the floor ,along the wall or along the pole complete all as specified and directed. 136 Taking down and refixing of ceiling fan after rewinding, overhauling, replacement of bearing, capacitor and capacitor stand,cleaning painting making serial No complete all as specified and directed by Enginner-in-charge.Note:- Cost of supply & fixing of celing fan box round cover plate is included in the unit rate quoted by contractor.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 07-10-2024 CORRIGENDUM NO 1 Date 30-10-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 78880.0 /-
Tender Value
Refer document

Attachment

FileName File Description File Size
Click here to download tender document Tender Notice 0 KB
Click here to download tender document Tender Document 0 KB
Click here to download tender document Tender Document 0 KB
Click here to download tender document Tender Document 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail