}

Tender For Provision Of Otm Accommodation At Hayuliang Under Ge P Lohitpur, Papum Pare-Arunachal Pradesh

Statutory Bodies & Commissions/Committees has published Tender For Provision Of Otm Accommodation At Hayuliang Under Ge P Lohitpur. Submission Date for this Tender is 24-10-2024. wrist watch Tenders in Papum Pare Arunachal Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

45316608
Tender For Provision Of Otm Accommodation At Hayuliang Under Ge P Lohitpur
Open Tender
Indian
Arunachal Pradesh
Papum Pare
24-10-2024

Tender Documents

Tender Details

Tender For Provision Of Otm Accommodation At Hayuliang Under Ge P Lohitpur; 2 Lumpsum price workedout by the tenderer for BUILDING& STRUCTURE WORKS as listed in Schedule ‘A’ Part-I(A) 3 Lumpsum price workedout by the tenderer for TRAVERSE RETAINING WALL ESH 1, 2, 3 & 4 as listed in Schedule ‘A’ Part-I(B) 4 Lumpsum price worked out by the bidder/ tenderer forSITE CLEARANCE, SITE DEVELOPMENTS & EARTH WORKS as listed in Schedule A Part-II. 5 Lumpsum price worked out by the bidder/ tenderer forINTERNAL WATER SUPPLYas listed in Schedule A Part-III. 6 Lumpsum price worked out by the bidder/ tenderer forINTERNAL ELECTRIFICATION as listed in Schedule A Part-IV. 7 Lumpsum price worked out by the bidder/ tenderer for ROAD, PATH, CULVERT & HARDSTANDINGas listed in Schedule A Part-V. 8 Lumpsum price worked out by the bidder/ tenderer for EXTERNAL WATER SUPPLY as listed in Schedule A Part-VI. 9 Lumpsum price worked out by the bidder/ tenderer for DG SET as listed in Schedule A Part-VII. 10 Lumpsum price worked out by the bidder/ tenderer for EXTERNAL ELECTRIC SUPPLY as listed in Schedule A Part-VIII. 11 Lumpsum price worked out by the bidder/ tenderer forAREA DRAINAGE as listed in Schedule A Part-IX. 12 Lumpsum price worked out by the bidder/ tenderer for COMPOUND WALL, FENCING & STEEL GATE as listed in Schedule A Part-X. 13 Lumpsum price worked out by the bidder/ tenderer for RETAINING WALLas listed in Schedule A Part-XI. 14 Lumpsum price worked out by the bidder/ tenderer for FIRE ALARM SYSTEM as listed in Schedule A Part-XII. 15 Lumpsum price worked out by the bidder/ tenderer for LIGHTNING PROTECTIONas listed in Schedule A Part-XIII. 16 Lumpsum price worked out by the bidder/ tenderer for FIRE FIGHTING SYSTEM as listed in Schedule A Part-XIV. 17 Sch A Sec-XV (Miscellaneous Items) Note : This schedule is not pre-priced by MES and the pre-priced rate indicated as Rs 0.00 under Col. 5 siginifies this fact only. 18 Material & Labour HDPE pipe of 75 mm dia of pressure rating 6 kgf/cm2 fixed to the retaining wall for the wheep holes complete all as specified and directed. 19 Supplying and stacking at site dump manure from approved source, including cariage upto 5KM lead complete (manure measured in stacks will be reduced by 8% for payment) Screened through sieve of I.S designation 20 mm complete all as specified and directed. 20 Supplying and stacking at site dump manure from approved source, including cariage upto 5KM lead complete (manure measured in stacks will be reduced by 8% for payment) Screened through sieve of I.S designation 16 mm complete all as specified anddirected. 21 Supplying and stacking at site dump manure from approved source, including cariage upto 5KM lead complete (manure measured in stacks will be reduced by 8% for payment) Screened through sieve of I.S designation 4.75 mm complete all as specified anddirected. 22 Rough dressing the trenched ground including breaking clods complete all as specified and directed. 23 Uprooting weeds from the trenched area after 10 to 15 days of its flooding with water including disposal of uprooted vegetation complete all as specified and directed. 24 Fine dressing of the ground complete all as specified and directed. 25 Spreading of sludge, dump manure and/or good earth in required thickness as per direction (cost of sludge, dump manure and/or good earth to be paid separately. complete all as specified anddirected. 26 Mixing earth and sludge or manure in the required proprtion specified or directed. 27 Grassing with selection No 1 Doob grass in rows 5 CM apart in both directions including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn, free from weeds and fit for mowing including supplying good earth, if needed (the grass and good earth shall be paid for seperately) complete all as specified anddirected. 28 Grassing with selection No 1 Doob grass with grass Turf including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn, free from weeds and fit for mowing including supplying good earth, if needed (the grass and good earth shall be paid for seperately) complete all as specified anddirected. 29 Renovating lawns including weeding, cheeling the grass, forking the ground, top dressing with sludge or manure, mixing the same with forked soil, watering and maintaining the lawn for 30 days or more till the grass forms a thick law free from weeds and fit for mowing and disposal of rubbish as directed, including supplying good earth if needed (the cost of sludge, manure and the food earth shall be paid for sepeately) complete all as specified anddirected. 30 Supply and fixing FRP Dunnage blocks of Size 300mm x 300mm x 200mm complete all as specified and directed. 31 Supply & fix concertina coil 600mm dia made from galvanized iron, wire dia 2.5mm central core wire made from high tensile spring steel high carbon wire conforming to IS 4454/Part-I/Grade-SM duly hot dipped galvanized, UTS 1670 N/mm2, Zinc coating with minimum 230 GSM weight per coil 8.5 Kg complete all as specified and directed. 32 Material & Labour for brick manhole of size 0.6 x 0.75 x 0.8 m including RCC M20 manhole cover including earthwork, PCC 1:4:8 type B0 using 12.5mm stone agreegate, one brick thick walls laid in 1:4 cement mortar, including reinforcement with RCC flooring including formwork, plastering with 15mm thick 1:4 cement mortar on external surfaces and 10mm thick using 1.4 cement mortar on internal surfaces etc. complete all as specified and as directed. 33 Material & Labour RCC CIRCULAR MANHOLE 1400ø x 1500mmincluding RCC M20 man hole cover including earthwork, PCC 1:4:8 type B0 using 12.5mm stone agreegate, RCC M25 walls, including reinforcement with RCC flooring including formwork, plastering with 15mm thick 1:4 cement mortar on external surfaces and 10mm thick using 1.4 cement mortar on internal surfaces etc. complete all as specified and as directed. 34 Material & Labour RCC CIRCULAR MANHOLE 600ø x 1500mmincluding RCC M20 man hole cover including earthwork, PCC 1:4:8 type B0 using 12.5mm stone agreegate, RCC M25 walls, including reinforcement with RCC flooring including formwork, plastering with 15mm thick 1:4 cement mortar on external surfaces and 10mm thick using 1.4 cement mortar on internal surfaces etc. complete all as specified and as directed. 35 Supply & Fix DOUBLE CORRUGATED PIPES of size 150mm, DWCPE (SN8) pipes laid on concrete bed of 150 mm thick PCC 1:3:6 type C2 (using 40 mm graded stone aggregate) complete all as specified and directed. 36 Supply & Fix Mild Steel RUNGS of size 300mm x 150mm moulded out of mild steel 12mm square bar duly painted with synthetic enamel paint of two coats over primer. Rungs shall be placed in RCC while casting of RCC complete all as specified and directed. 37 Supply & install, test and commissioning of automatic power factor control (APFC) panel indoor type for 80 KVAR, 3 Phase, 440 Volts, 50 Hz with multistage correction (MPP-H capacitor) copacitor operate in 7 steps configuration will be (2 x 20 KVAR,3 x 10 KVAR and 2 x 5 KVAR prewired all suitable for fairly balance load factory made mounted on 50 mm x 50 mm x 6 mm thick angle iron frame front operated factory made prewired with suitable size copper conductor cable fabricated out of 2 mm thick CRCA shete painted with epoxy powder coating after dip coated rust proof treatment in havells grey colour structural RAL-7035, 6mm thick fibre sheet for mounting electrical accessories and connection with PVC/XLPE insulated UG Cables with provision of glands lugs etc with suitable gland plates at bottom including fixing arrangements cement concrete work for foundation of panel etc & Panel consisting of the following all as specified & directed. (Installed at Sub Stn (a) MCCB, 160 Amps, 16 KA, TPN, 4 Pole, 415 Volts - 1 No (Incomer) (b) CTs Shall be provide for measuring the capacitor current at incoming side of the panel (c) The APFC Panel shall be provide with emergency push button to de-energies the control circuit incase of emergency or any fault occuring in the panel(d) APFC relay displaying various selectable/programmable electrical parameters like voltage input current capacitive current KVA demand KW Power factor etc(e) Fast response time of switching ON of Power factor (f) The Panel shall contain suitable rated with filter for cooling (g) Capacitors shall conform to IS-13340 & IEC-83, Contactor shall conform to IS-13947 and APFC relay shall be microprocessor based to operate in 6 stages(h) For individual capacitor bank MCB shall be provided(i) RYB Phase indicator LED type with protection MCB - 1 set (j) Locking arrangement complete 38 Supply, install, testing & commissioningHT 11 KV, 3 phase 50 Hz, indoor type, totally enclosed metal clad switchgear complete with Vacuum Circuit Breaker having rupturing capacity 350 MVA, overload and earth fault protection, ammeter, voltmeter and of rating upto 800 Amp complete all as specified and directed. 39 Supply and fix HT 11 KV out door type gang operated air-break switch suitable for horizontal or vertical mounting rotating type complete with drop out fuse having 12 insulators of rating upto 200 Amps complete all as specified and as directed 40 Supply, install, testing and commissioning oftransformer step down, out doortype complete with standard fittings, HT 11 KV 3 Phase, LT 433 volts, 3 Phase4 wirewith off load tappings on HT side to vary secondaryvoltage within limit, all as per IS:2026 of capacity 500 KVA with EEL-3 complete all as specified and as directed 41 Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, aluminium conductor cable, Indoor/Outdoor type for thesize 25 to 50 sqmm complete all as specified and as directed 42 Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, aluminium conductor cable, Indoor/Outdoor type for thesize 70 to 95 sqmm complete all as specified and as directed 43 Supply and Fix LED foodlight luminaire,120 Watts, with pressure die-cast aluminium housings secondary optics, CRI >70, CCT 5700+300 °K, Power Factor >95%, THD <10%, Driver Effciency >85%,lumen efficacy >110 Lm/W, LED Driving Current 1.3-2.3A, AC input voltage 140V-275V, surge protection 5 KV internal & 10 KV external and degree of protection IP 66, complete all as specified and directed. 44 Material & Labour for earthing with galvanised steel earth plate electrode of size 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to the galvanised earth lead by means of bolts, nuts check nuts and washers of galvanised iron or steel using GI or steel wire 4 mm dia as earthing lead as shown in electrical plate No. 3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on completion including necessary excavation and earth work in soft/loose soil, returning filling, disposal of surplus soil, earth pit in PCC 1:3:6 type C-1 using 20mm graded stone aggregate pit, funnel, 20mm dia GI medium grade watering pipe, 15mm dia GI light grade earth lead protection pipe, CI frame and cover, wire, copper lugs etc mesh, chorcoal and common salt in alternatee layer complete all as specified and directed by Engr-in-Charge.Note :- Length of earthwire and protection pipe in above mentioned item is considered upto 7.50 m length, additional length required shall be measured and paid separately. 45 Material & Labour for earthing with galvanised steel earth plate electrode of size 60cm x 60 cm x 6mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to the galvanised earth lead by means of bolts, nuts check nuts and washers of galvanised iron or steel using GI strip 32x6mm as earthing lead as shown in electrical plate No. 3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on completion including necessary excavation and earth work in soft/loose soil, returning filling, disposal of surplus soil, earth pit in PCC 1:3:6 type C-1 using 20mm graded stone aggregate pit, funnel, 20mm dia GI medium grade watering pipe, 40mm dia GI medium grade earth lead protection pipe, CI frame and cover, wire, copper lugs etc mesh, charcoal and common salt in alternatee layer complete all as specified and directed by Engr-in-Charge.Note :- Length of earthwire and protection pipe in above mentioned item is considered upto7.50 m length, additional length required shall be measured and paid separately. 46 Supply & Fix Wiring 2 runs of 1.5 sqmm PVC insulated copper cable HRFR-LSH with ISI mark drawn through surface type flame proof 16 SWG steel conduit including flame proof junction boxes and accessories complete all as specified. 47 Supply & Fix stay wire Galvanised stay strand (Grade2), size 7/4.00mm all as specified and directed. 48 Supply & Fix 150mm bore sluice valve (operation-cap) both side flanged, ISI marked (IS No 14846-2000 class PN-1.6) having cast iron body, cast iron hand wheel, non rising type with brass spindle, cheek nuts and sliding gate type body including testing against any leakages complete all as specified and as directed. 49 Supply & Fix 100mm bore sluice valve (operation-cap) both side flanged, ISI marked (IS No 14846-2000 class PN-1.6) having cast iron body, cast iron hand wheel, non rising type with brass spindle, cheek nuts and sliding gate type body including testing against any leakages complete all as specified and as directed. 50 Supply & Fix 80mm bore sluice valve (operation-cap) both side flanged, ISI marked (IS No 14846-2000 class PN-1.6) having cast iron body, cast iron hand wheel, non rising type with brass spindle, cheek nuts and sliding gate type body including testing against any leakages complete all as specified and as directed. 51 Supply & Fix 50mm bore sluice valve (operation-cap) both side flanged, ISI marked (IS No 14846-2000 class PN-1.6) having cast iron body, cast iron hand wheel, non rising type with brass spindle, cheek nuts and sliding gate type body including testing against any leakages complete all as specified and as directed. 52 Supply and fixing 150mm bore, cast iron Non return valve, flange type with by pass arrangement class PN 1.6 complete all as specified and as directed. 53 Supply and fix Gun metal fire brigade inlet connection 2 wayto external fire hydtrant main consisiting of two nos 63mm dia instantaneous type male coupling with built in valves and 150mm dia, flanged outlet complete with all acessories complete all as specified and as directed. 54 Supply & Fix fire hydrant landing valve type A of size 63 mm dia(single head) complete with instantaneous coupling complete.(IS 5290) complete all as specified and as directed. 55 Supply and fix 63mm dia 30 meter long rubberised fabric reinforced rubber lined hose including gun metal male & female instataneous coupling, hose confirming to IS 636 type II and coupling confirming to IS 903-1975 complete all as specified and as directed. 56 Supply and fix Pressure guage 100mm dia with ball valve of pressure 21KG/Sqmm all as specified. 57 Material & Labour for stand post type fire hydrant, conforming to IS 908: 1975, consisting of two Class- I type sluice valves with cap, road surface boxes, a duck foot bend, flange riser and an 80 mm NB CI flanged stand post column of 1.5 m height, perfectly water tight under a hydraulic pressure of 200 m head along with coating and painting complete as specified and directed. 58 supply and fix flow switch on pipes with welded socket including stainless steel paddle suitable to pipe dia. 100 mm testing and commissioning etc. complete. 59 supply and fix flow switch on pipes with welded socket including stainless steel paddle suitable to pipe dia. 150 mm testing and commissioning etc. complete. 60 Supply & fix UPVC pipe (sch-40) 50mm dia for borewell pump complete all as specified and directed. 61 Supply, instalation, testing & commissioning of Analogue Addressable Main Fire AlarmControl panel complying with BS EN 54 shall be with switch mode power supply, battery back up and charger. The panel shall have 8 loops as capacityfrom 99 detectors & 99 modules with the option of using 1/2 loops and with 200 devices per loop in any combination. The panel shall consisting with 160 character LCD display, Touch keys shall be networkable by RS 485 or TCP/IP, repeater/Mimic connectivity. USB - 2.0 for PC Interface. Degraded redundancy operating mode when the main CPU fails complete all as specified and directed. 62 Supply and fix suspended type air termination network, protective angle min 30 deg, & supporting pole should be positioned at least 2m form site, height of pole 6meter, air termination al rod 16mm dia & 1000mm long complete all as specified and directed. 63 Supply & Fix 300mm bore sluice valve (operation-cap) both side flanged, ISI marked (IS No 14846-2000 class PN-1.6) having cast iron body, cast iron hand wheel, non rising type with brass spindle, cheek nuts and sliding gate type body including testing against any leakages complete all as specified and as directed. 64 Supplying and fixing Reflux Valves (NRV) with by pass arrangement supplied and installed complete of size 300 mm complete all as specified and directed. 65 Material & Labour for constructing brick masonary Chamber 60 x 60 x 60 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for valve chamber, with FRP cover with frame 600 x 600mm internal dimensions (10 ton load bearing) including necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design complete all as specified. 66 Supply and install Fire pump diesel engine driven horizontal end suction, centrifugal type confirming to IS-12469-1988 with CI Casing, broze impeller and stainless steel shaft mounted on heavy duty bearing suitable for continuous operation with the range of operation 0 % to 150 % of rated capacity for 440V, 3 Phase, 50 HZ AC supply 75m Head 6825 LPM discharge, speed 2900 RPM all as specified. 67 Supply and installing Fire pump electrically driven horizontal end suction, centrifugal type confirming to IS-12469-1988 with CI Casing, broze impeller and stainless steel shaft mounted on heavy duty bearing suitable for continuous operation with the range of operation 0 % to 150 % of rated capacity for 440V, 3 Phase, 50 HZ75m Head 6825 LPM discharge,speed 1800 RPM all as specified. 68 Supply, Installation, Testing, Aligning and proper leveling and commissioning of Jockey pump horizontal end suction centrifugal type Confirming to IS-12469:1988 with CI casing, bronze impeller and stainless steel shaft mounted on heavy duty bearings suitable for automatic operation with nanover loading power characteristics for frequent start I stop operations for 440 V, 3 phase, 50 Hz 75 m head 500 LPM discharge complete all as specified and directed. 69 Supplying, installing and commissioning of ABC Powder 9 Kg Fire Extinguisher containing Mono Ammonium Phosphate Powder, Stored Pressure Type, Pressure Gauge, fittted with discharge hose, wall mounting bracket etc., Discharge Time less than 15 Secs, Controllable discharge mechanism, Range minimum 4 Meters, applicable on Class A,B,C and electrically started Fire, A Rating- 8A, B Rating 34B, Can Construction : Deep drawn & Co2 Mig welded, Valve Construction : Forging & Machining, Internal Coating of Can : Epoxy Powder coating, External Coating of Can : Epoxy Polyster Powder coating, Sheet metal thickness : 1.60 mm, ISI approved as per IS:15683:2006 complete all as specified and directed. 70 Supply & Fix fire Extinguisher Water CO2/stored pressure type 9 liter capacity , gross weight 12kg,should be recharble,discharge hose shall be as per clause 9.8 of IS 15683, operating pressure with 10-15 bars, body mild steel,valve assembly forged brass ,bracket mild steeel , discharge time not less than 45 sec. ISI approved as per IS :15683:2006 complete all as specified and directed. 71 Supply & Fix fire buckets IS 2546 (FILLED WITH SAND) round bottom type enamel painted, white inside & Red out side and Letter FIRE in black out side and handle with mounting bracket complete all as specified and directed. 72 Supply fire beaters as per(IS:8096), made of Carbon (Mild steel) frame and steel mesh, and having bamboo handle suitable firefighting Clsss A fires complete all as specified and directed. 73 Supply and fix Crow bar as per (IS:704-1984), made of iron, color black, length 3 feet for fire fighting. 74 Supply and fix Fire hook as per (IS:927-1981), made of mild steel, color redfor fire fighting. 75 Supply & fixing fire sign board IS 9457-2005 triangle shape, material acrylic, yellow printed, height of letter 10mm, height of sign board 150mm complete all as specified and directed. 76 Supply & fixing fire hazard Sign board for (URPHD 1.1,1.2,1.3&1.4), octagon shape, cross shape, inverted triangle, diamond shape)material aluminium, orange & blabk printed, height of letter 20mm, height of sign board 1200mm complete all as specified and directed. 77 Supply & fixing first aid board IS 9457-2005 rectangle or square shape, material aluminium, green& white printed, height of letter15mm, height of sign board plate 225mm, thickness upto 10mm complete all as specified and directed. 78 Supply & Fix water monitors of size 100mm as per IS 13039 stand post type with material of construction beign in gun metal /stainless with flanged inlet with jet and sparay type hydra foam nozal /aluyminium barrel type 63mm size suitable for operation at working pressure 1to 1.4 mpa complete all as specified and directed. 79 Supply & Fix Iron Removal cum Pressure Fiter plant (to improve iron content 10 PPM incoming to 0.3 PPM) shell: 8 mm, dish & bade plate 10 mm working pressure 3.5 kg / cm2 with oxidation chamber, inlet, outlet, backwash, rinse facilities, and complete provision of man hole, hand hole, under bed plate fitted with pvc strainer, air vent system, C I Butter Fly valves (wefer and lever operated), MS / UPVC Frontal Pipeline (medium grade), suitable air compressor, 06 ltrs/hr @ 04 kg back pressure, 100 ltrs capacity solution preparation cum settling tankfitted with gear motor and S S agitator, filter medias, Mno2 etc as complete including suitable civil platform with foot stool foundation including drain and pit to accommodate the entire plant, painting- entire filtration plant as final paint, Misc fittings - likeTee, Bend, Sluice valves, MS pipe in required length and quantity including welding to connect filter plant with existing raw water line of capacity 22500 lph complete all as specified and directed. 80 Supply, installation, testing and commissioning of 2.0 Ton capacity manually operated chain pully block with 6 mt chain and all acessories all as per detailed specifications and direction. 81 Supply, install, testing and commissioning of centrifugal pump set mono block, electrically driven 3 ph, 415 volts, F class insulation IP 55 protection completed with pumpset MS metal body, CI impeller with discharge 1000 LPM & minimum head 50 mtr, suction and delivery size 100x100 mm including base frame and brass metal body footvalve 100 mm dia ISI mark dia, pressure guage 0 to 7 Kg/cm2, necessary electrical connections from starter to motor with 10 sqm copper conductor including foundations as per manufactures specifications complete all as specified and directed . 82 Supply, laying and jointing of ductile iron pipes of 150mm bore with spigot and socket ends conforming to IS 8329 : 2000, suitable for push on rubber joint centrifugally cast, class (K-9), inner side cement lining and outer side black bitumen coating andany length, laid in trenches or fixed in floors or on walls including push on rubber (EPDM) ring with ISI marked complete all as specified and directed.Note: Ductile iron fitting such as Bends (any type, radius and angle), tapers any type (straight, bend, increasing, decreasing or double socket etc.) Tee pieces single branch. Y junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs of suitable size are deemed to be included in the quoted rate. 83 Supply, laying and jointing of ductile iron pipes of 100mm bore with spigot and socket ends conforming to IS 8329 : 2000, suitable for push on rubber joint centrifugally cast, class (K-9), inner side cement lining and outer side black bitumen coating andany length, laid in trenches or fixed in floors or on walls including push on rubber (EPDM) ring with ISI marked complete all as specified and directed.Note: Ductile iron fitting such as Bends (any type, radius and angle), tapers any type (straight, bend, increasing, decreasing or double socket etc.) Tee pieces single branch. Y junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs of suitable size are deemed to be included in the quoted rate. 84 Material & Labour for PVC insulated sheathed water proof flat submersible cable 3 core 6 Sqmm complete all as specified and as directed. 85 Supply, install, testing and commissioning of Submersible pumpset, electric driven 415 V, TP suitable for 150 mm dia bore well with discharge 550LPM & minimum head 100 mtr, necessary electrical connections as per manufactures specifications complete all as specified and directed. 86 Supply, installation, commissioning and testing of cubical type pump control panel outdoor type made out of CRCA sheet 3.15 mm thick with powder coated painting and four Nos of 100 amps Aluminium strips/ bars duly insulated mounted on insulators/ suitable size conforming to IP 65 classification, CPRI approved bakelite sheet and including voltmeter, ammeter with selector switches for incoming and outgoing, CTs, RYB indicating lamp, PVC insulated copper cable for control wiring, steel cable glands of suitable size, complete and comprising of the following incoming / outgoingcomplete all as specified and as directed :- (i) MCCB TP 32 Amps - 01 No (ii) Volt meter0-500 Volts with selectorswitch - 01 No (iii)Amp meter 0 to 200 with CTs selector Switch - 01 No (iv) Indicating lamp set of 3 - 01 Set (v)Aluminium busbar FP 100 Amps - 01 set (vi) Capacitor 5 KVAR with Contactor - 01 No (vii) Single phasing preventer - 01 No(viii) Suitable Submersible Pump Starter fully automatic 415 volts-1Nos (ix) Supply and fix time switches 415 V three Phase of 20 Amp rating with contactor Fitted inside steel enclosure 87 Material & Labour for drilling of trail bore of size 250 mm dia upto 200mtr depth below ground at given site perfectly vertical with reverse rig circulation method by direct rotary mechanical system or any latest technology through any kind of soil strata of the layers, including hard stone /boulders etc to the complete depth including submitting the strata details duly graphically recorded for injection well in any type of soil strata including hard stone/boulders including disposal of soil from the site complete all as specified & directed. 88 Material & Labour for drilling of bore not less than 400 mm dia suitable for200 mm dia housing pipe upto 30 mtrs depth below ground level (BGL) and 30 to 100 m BGL for 150 mm dia pipe by combination rig (DTH + Reverse Rotary Rig Method), through any kind of soil, boulders, rocks etc. as required at site including disposal of spoil from the site of work complete all as specified & as directed.Note:(i) After complete drilling of the trial bore/ bore electric logging shall be carried out for exact selection of strata & the same will be measured & paid separately under relevant items of schedule. Pipe quantities/ Gravel given below shall be measured and paid accordingly for the depth of borewell required and quantity executed at site irrespective of quantity of material brought at site(ii) In case the results of the borehole/ strata are found un-satisfactory & the tubewell is not likely to yield the specified quantity of water, the site will be abandoned & the contractor shall be paid for the boring only. 89 Shifting of T&P to site and back for and including Electric logging of bore for precise delineation of granular zones & also the quality of ground water including report interpretation complete all as specified & as directed.NOTE:- Electric logging shall be carried out by any approved Govt Agency 90 Supplying and assembling including jointing, lowering & fixing in position ERW casing pipe fine cut of internal dia 200 mm bore of thickness 6.35mm conforming to IS 4270-2001 or IS 3589 (ISI marked),screwed, socketed includingjointing of pipe by necessary electric arc weldingwith04 Nos stiffners of flat iron 40 x 6mm thick, 300 mm long both sides. The pipe shall be duly painted with anti-corrosive paint suitable for drinking water purpose complete all as specified & directed. 91 Supplying and assembling including jointing, lowering & fixing in position ERW casing pipe fine cut of internal dia 150 mm bore of thickness 5.4mm conforming to IS 4270-2001 or IS 3589 (ISI marked), screwed, socketed including jointing of pipe by necessary electric arc weldingwith04 Nos stiffners of flat iron 40 x 6mm thick, 300 mm long both sides. The pipe shall be duly painted with anti-corrosive paint suitable for drinking water purpose complete all as specified & directed. 92 Supply lowering and fixing/ jointing 150 mm bore low carbon galvanised (LCG) strainer min 5.4 mm thickness each conforming to IS 8110:2000 including mild steel socket threaded/ by electric arc welding both sides all as specified anddirected with aperture 0.75 mm to 1 mm as per requirement. Pipes shall be of length ~ 6 m unless required in smaller lengths as per borewell requirement complete all as specified & directed. 93 Material & Labour for MS Taper reducer of 200 x 150 mm made out of 10 mm thick sheet with and including socket threaded as per IS 226: 1975 and by electric arc welding both sides complete all as specified and as directed. 94 Supply and fixing bail plug of 150 mm internal dia threaded of minimum thickness 6.35 mm and 3 mtr long made up of mild steel and continuous welded by electric arc welding at both ends complete all as specified as per IS 226: 1975 and directed. 95 Material and labour for packing pea graval 3 to 5 mm (or as per Geologist report) of size as per IS of natural shapebrought directly from river bed duly screened and packing around the casing pipe of MS to entire depth of tubewell upto ground level complete all as specified & as directed. 96 Supply and fixing well cap as per IS 226 : 1975 suitable for 200 mm bore housing pipe made out of 6 mm thick steel plate complete all as specified and directed. NOTE : After completion of the work well cap will be used to keep the bore well closed until the submersible pumping set is installed. 97 Material & Labour for development of tube well with air compressor as per IS 11189-1985 of suitable capacity till sand/mud free water of potable quality is obtained & to achieve (Compressor with accessories & tube etc. shall be arranged by the contractor) complete all as specified & as directed. 98 Development of tube well as per IS 11189: 1985 by over pumping 25% using suitable size/type pump after completion of item above, including yield testing for both tube wellas per IS 2800-2 1979. NOTE :-Yield test of both bore well shall be carried outin the presence of rep of Accepting Officer. 99 Supply only strata sample box with glass cover 3mm thick having internal dimension 1000x600x100mm made out of 20mm thick wrought Ist class hard wood with hinges, hasp and staple including polishing complete with samples at various depth evenly 2 mtr interval met in boring including lithological log strata chart in duplicate all as directed and specified.Note : The contractor should also make and provide a record of discharge, draw down and depth to water level duly recorded in duplicate for official information and record. 100 Material & Labour for sanitary sealing of tube well with PCC (1:2:4) type B1 of suitable size using 20 mm graded aggregate of size 1mx1mx1m with embedded gravel feed pipe of GI medium grade 80 mm bore 2 m long with cap complete all as specified and as directed 101 Testing of raw water & treated water from approved Govt lab for potability by doing chemical (specially for iron (Fe), fluroide (F) and arsenic (As)) and bacteriological analysis as per norms of WHO and submission of test reports to the entire satisfaction. 102 Supply & Fix mild steel well clamp suitable for 200 mm dia MS column pipe made out of 12 mm thick MS plate fabricated to shape, including drilling holes, nuts, bolts, washers etc complete all as specified as per IS 226: 1975 complete all as specified and as directed 103 Supply & Fix centering guide suitable for 150 mm dia screen pipe with sizes as per IS 2800 Part I complete all as specified and as directed 104 Fixing cost for MS reducer, bail plug, well cap, MS strip for centering , MS Iron clamps, electric logging and sample strata box complete all as specified and as directed 105 Water test analysis (chemical & biological) for bore well instalation conforming to relevant IS Codes complete all as specified and as directed 106 Supply, installation, testing and commissioning of silent type Diesel Engine driven Generating set ISI marked Water cooled type,BHP 200 @ 1500RPM415 volts, 3 phase 4 wire (Engine as per IS: 10001/10002 and alternator as per IS: 13364) complete with foundation as per manufacturers recommendation, standard AMF panel with necessary protection and meters including sound proof canopy of capacity 160 KVAincluding the following: -Note : DG Set should be as per CPCB IV or latest higher specification. (a) ENGINE Diesel engine prime mover of suitable BHP to drive 160 KVA alternator with the following: - 107 Sr. Item No. 15.089(Contd/....)(i)Fuel level indicator(ii)Fuel tank of suitable capacity for storing minimum 8 hrs consumption capacity at 75% load.(iii) Fuel inlet arrangement from outside the acoustic enclosure with locking arrangement.(iv) Robust, MS base frame with anti vibration damper pads(v)Continuous 10% overload capacity in every 12 Hrs running.(vi) Self starting with and including suitable maintenance free battery of suitable AH rating as per OEM specification including charging circuit.(vii) Mechanical or Electronic governor as per OEM specification (b) ALTERNATOR160 KVA at 0.8 PF (lag), 415 volt, 3 phase, 4 wire, 50 Hz, 1500 RPM copper wound with the following: -(i) Self regulated brushless self excitation.(ii)Automatic voltage regulator with band of voltage regulation: + 2.5% of rated voltage.(c)AMF CONTROL PANEL Factory fabricated free standing AMF panel with suitable size copper bus bar with the following: -(i) MCCB 4 pole, 415 Volt, 3 phase of 250 Amps, 25 KA as per OEM. (ii) Internal wiring with suitable size copper conductor(iii) Start and Stop push button(iv)Digital voltmeter with selector switch (v) Digital frequency meter (vi)Digital ammeter with 3 Nos CT and selector switch(vii) Digital power factor meter (viii)Three phase energy meter (ix)Tripping arrangement with hooter for High engine temp, Low lub oil pressure, High lub oil temp, Low and high engine speed etc as per manufacturers design. (d) ACOUSTIC ENCLOSURE It should be compact, modular construction and approved by ARAI (nodal agency of CPCB) with the following: -(i) Overall noise level less than 75 dB measured at 1 mtr distance in free field condition.(ii) Inside illumination provide with 2 Nos 1 x 9 watt LED light fitting or as per manufacturers design. Note: - (i) The cost of foundation for installing the DG Setas per manufacturers recommendation and is deemed to be included in the quoted rate.(ii) First filling of fuel (DHPP(N) for 12 hours load test purpose including arrangement of artificial load shall be provided and cost deemed to be included in the quoted rate.(ii) Any accessories not mentioned but included in manufacturers standard modules are deemed to be included in the quoted rate. 108 Supply & fixing 45W LED street light fitting with pressure die-cast housing with toughened glass and individual LEDs with secondary optics and IP 66 protection complete all as specified and as directed. 109 Supply and install hot dip galvanized steel (IS 5986 Gr FeE 510E) octagonal pole 7.0 meters long, top dia 70mm, bottom dia 130mm having thickness 3mm having door opening of size 500mm above 500 mm from ground level, with CI base plate of size 240x240x16mm having PCD 220mm, foundation J bolts M20x700mm (570+130of J), nuts and screws and having hot dip galvanized single plain arm bracket 1000mm overhang fixed on top with bolts including connection cable from junction box to light fitting @ 6Rm/Each pole complete all as specified. Note:-(a) Earthwork and PCC will be measured and paid under appropriate items in of Schedule A/BOQ. PCC for fundation of pole shall be as per manufacturs instruction.(b)Volume occupied by Steel Pole shall be deducted to derive the quantity of PCC. 110 Supply & installation of Galvanized Steel High Mast lighting system for 16 meter hight mast in two shafts with 20 sided polygon cross section, (top 150 mm & bottom 360 mm bore, min) and sheet thickness 3mm for top & 4mm for bottom (min), size of base plate should be 540 mm dia, 25 mm thick (min), hot dip galvanised (confirming to IS 4270)and suitable for wind velocitty as per IS 875, Part-III with all its standard accessories including head frame, luminaries carriage suitable to install 09 Nos 250 Watts light fittings and double drum winch with 3 Nos steel wire rope system of min 6 mm dia, 4.0 sq mm 5 core trailing cable with copper conductor, connectors, integral power tool motor of suitable capacity with raising/lowering manual system comprising of handle, junction box, lightning finial, anchoringfoundation bolts of sizes M25X 750mm, AOL fixing arrangement andother accessories.(Rates of Excavation, RCC foundation as per the approved design of OEM are exclusive of above item which will be measured and paid separetly ). Note :- Material Specifications a) Mast & pole shaft- BSEN 10025, ASTM A572, IS 5986 b) Foundation : IS 2062/E250Ac) Base Plate : IS 2062 d) Galvanisation : IS:4759/2629 & ASTM A123 111 Supply and fix cable route indicator oval shaped of size 200x150x6mm thick made out of Cast Iron with letter embossed as LT UG Cable fixed to 25x25x6mm mild steel angle iron 450mm long embedded in PCC block of size 200x200x200mm in PCC 1:3:6 type C1 using 20mm graded stone aggregate and including painting two coats of synthetic enamel paint over a coat of redoxide zinc chrome premier on exposed steel surfaces complete all as specified and as directed 112 Supply, install, test & commissioning of factory fabricated indoor Main LT Panel panel weather & vermin proof IP 65 Classdouble door totally enclosed on 40 mm x40 mmx 6 mm thick angle iron frame, Cubicle modular made out of 3.15 mm thick CRCA sheet with epoxy powder coated dip coated primer duly painted with rust proof Siemens gray structural RAL 7032 paint, 6mm thick fiber sheet for mounting MCB/MCCBs and other accessories earth bus strip etc & with all interconnections, risers, internal wiring, labels, terminal blocks etc. complete as required and connection with existing PVC/XLPE insulated cable with provision of joints, lugs, gland, etc all as specified & directed and consisting of the following including necessary PCC work for foundation excavation & earthwork etc complete., suitable for operation 3 Phase, 4 wire, 440 volt, 50 Hz, AC system & consisting of following accessories:- Incoming:1 No. of 1000 Amp 4PACB of 65 KA Breaking capacity with single phase to ground fault relay. Metering for incoming:Digital VAF + PF meter, Cl 1 (L&T 4110 series) flush mounting type with CTs as required. RYB Phase indicator LED type with protection MCB - 01 Set Bus Bars: Electrolytic high conductivity Aluminium three phase and neutral busbars rated at 1500 Amps, insulated with heat shrinkable coloured PVC sleeves & clip on shrouds for joints. Outgoing : (a) 03 No.160A TPN MCCB of 25 KAbreaking capacity. (b)1Nos 320 A TPN MCCB of 36 KAbreaking capacity (c) 05 Nos 63A. 25 A TPN MCCB of 16 KAbreaking capacity 113 Supply, install, test and commisioning of factory fabricated LT panel, outdoor type mounted on 50 mm x 50 mm x 6 mm thick angle iron frame, cubicle modular made out of 3.15 mm thick CRCA sheet with epoxy powder coated after dip coated primer duly painted with rust proof Siemens gray structural RAL 7032 paint, 6 mm thick fibre sheet for mounting MCBs/ MCCBs and other accessories, earth bus strip etc & connection with existing PVC/XLPE insulated cable with provision of joints, Lugs, glands etc all as specified & directed and consisting of the following including necessary PCC work for foundation excavation & earthwork etc complete, suitable for operation 3 Phase, 4 wire , 440 volt, 50 Hz AC system & consisting of following accessories complete all as specified & as directed.:-(a) Aluminium bus bar 200 Amps rating, 4 Pole, 415 volts, TPN, colour coated with PVC/epoxy insulation & mounted insulator - 1 set of TPN (RYBN) (b) RYB Phase indicator LED type with protection MCB - 1 set (c) CRCA sheet chamber for bus bar, MCCB/ MCB, Meter etc complete(d) MCCB 4 Pole with thermal-magnetic release, 63 Amps TPN, 25 KA, 415 volt, AC, 50 Hz with necessary connection control wiring & accessories etc complete all as specifed & directed -1 No (incoming) 114 Sr Item No. 15.095 Contd/.... (e) MCCB, 415 Volts, 10 Amps, 16 KA, AC, 50 Hz, 3 Pole,TP with thermal & magnetic setting including necessary connections - 3 Nos (outgoing) (f) MCCB, 415 Volts, 20 Amps, 16 KA, AC, 50 Hz, 3 Pole,TP (relay range 30-63) with thermal & magnetic setting including necessary connections complete with earth fault protection - 3 Nos (outgoing) (g)MCCB, 415 Volts, 16 Amps, 16 KA, AC, 50 Hz, 3 Pole,TP (relay range 20-32) with thermal & magnetic setting including necessary connections complete with earth fault protection - 3 Nos (Outgoing) (h) MCCB, 415 Volts, 32 Amps, 16 KA, AC, 50 Hz, 3 Pole,TP (relay range 20-32) with thermal & magnetic setting including necessary connections complete with earth fault protection - 1 Nos (Outgoing) ((j) Digital multifunction meter with all electrical parameters like V, A, F, PF, KW, KVA, KWh, etc. - 1 No. (k) Control wiring with FR grade PVC insulated copper cable of suitable rating with necessary CTs & locking arrangement with DC panel lock Note :Panel shall be IP 54 Class CPRI approved and contractor shall submit CPRI Test Certificate to the Engineer-in-Charge(LT panel-01) 115 Supply, install, test and commisioning of factory fabricated LT panel, outdoor type mounted on 50 mm x 50 mm x 6 mm thick angle iron frame, cubicle modular made out of 3.15 mm thick CRCA sheet with epoxy powder coated after dip coated primer duly painted with rust proof Siemens gray structural RAL 7032 paint, 6 mm thick fibre sheet for mounting MCB/MCCBs and other accessories, earth bus strip etc & connection with existing PVC/XLPE insulated cable with provision of joints Lugs gland etc all as specified & directed and consisting of the following including necessary PCC work for foundation excavation & earthwork etc complete, suitable for operation 3 Phase, 4 wire , 440 volt, 50 Hz AC system & consisting of following accessories complete all as specified & as directed.(Installed at Sub Stn -3):- 116 Sr. Item No. 15.096 Contd/...(a) Aluminium bus bar 300 Amps rating, 4 Pole, 415 volts, TPN, colour coated with PVC/epoxy insulation & mounted insulator - 1 set of TPN (RYBN) (b) RYB Phase indicator LED type with protection MCB - 1 set (c) CRCA sheet chamber for bus bar, MCCB/ MCB, Meter etc complete(d) MCCB 4 Pole with thermal magnetic release, 160 Amps TPN, 36 KA, 415 volt, AC, 50 Hz with necessary connection control wiring & accessories etc complete all as specifed & directed -1 No (incoming) (d) MCB, 415 Volts, 16 Amps, 10 KA, AC, 50 Hz, 3 Pole,TP with thermal & magnetic setting including necessary connections - 4 No (outgoing) (e) MCB TP, 415 Volts, 10 Amps, 10 KA, AC, 50 Hz, 3 Pole,TP with thermal & magnetic setting including necessary connections - 2 No (outgoing) (g) MCB, , 20 Amps, 16 KA, AC, 50 Hz, 3 Pole,TP with thermal & magnetic setting including necessary connections - 1 No (outgoing) (h) MCB, 415 Volts, 32 Amps, 16 KA, AC, 50 Hz, 3 Pole,TP with thermal & magnetic setting including necessary (l) Digital multifunction meter with all electrical parameters like V, A, F, PF, KW, KVA, KWh, etc. - 1 No. (m) Control wiring with FR grade PVC insulated copper cable of suitable rating with necessary CTs & locking arrangement with DC panel lock Note :Panel shall be IP 65 Class CPRI approved and contractor shall submit CPRI Test Certificate to the Engineer-in-Charge (LT panel -02). 117 Supply, install, test and commisioning of factory fabricated LT panel, outdoor type mounted on 50 mm x 50 mm x 6 mm thick angle iron frame, cubicle modular made out of 3.15 mm thick CRCA sheet with epoxy powder coated after dip coated primer manual type control, rust proof Siemens grey, structural RAL 7032, 6 mm thick fibre sheet for mounting MCB/MCCBs and other accessories, earth bus strip etc & connection with existing PVC/XLPE insulated cable with provision of joints Lugs gland etc all as specified & directed and consisting of the following including necessary PCC work for foundation excavation & earthwork etc complete, suitable for operation 3 Phase, 4 wire , 440 volt, 50 Hz AC system & consisting of following accessories complete all as specified & as directed.(Installed at Sub Stn -3):- (a) Aluminium bus bar 300 Amps rating, 4 Pole, 415 volts, TPN, colour coated with PVC/epoxy insulation & mounted insulator - 1 set of TPN (RYBN) (b) RYB Phase indicator LED type with protection MCB - 1 set (c) CRCA sheet chamber for bus bar, MCCB/ MCB, Meter etc complete(d) MCCB 4 Pole with thermal magnetic release, 63 Amps TPN, 36 KA, 415 volt, AC, 50 Hz with necessary connection control wiring & accessories etc complete all as specifed & directed -1 No (incoming) 118 Sr. Item No. 15.097 Contd/....(d) MCB, 415 Volts, 16 Amps, 10 KA, AC, 50 Hz, 3 Pole,TP with thermal & magnetic setting including necessary connections - 1 No (outgoing) (e) MCB TP, 415 Volts, 10 Amps, 10 KA, AC, 50 Hz, 3 Pole,TP with thermal & magnetic setting including necessary connections - 4No (outgoing) (g) MCB, , 20 Amps, 16 KA, AC, 50 Hz, 3 Pole,TP with thermal & magnetic setting including necessary connections - 1 No (outgoing) (h) MCB, 415 Volts, 32 Amps, 16 KA, AC, 50 Hz, 3 Pole,TP with thermal & magnetic setting including necessary-2nos(outgoing) (l) Digital multifunction meter with all electrical parameters like V, A, F, PF, KW, KVA, KWh, etc. - 1 No. (m) Control wiring with FR grade PVC insulated copper cable of suitable rating with necessary CTs & locking arrangement with DC panel lock Note : Panel shall be IP 65 Class CPRI approved and contractor shall submit CPRI Test Certificate to the Engineer-in-Charge (LT panel -03). 119 Supply, install, test and commisioning of factory fabricated LT panel, outdoor type mounted on 50 mm x 50 mm x 6 mm thick angle iron frame, cubicle modular made out of 3.15 mm thick CRCA sheet with epoxy powder coated after dip coated primer manual type control, rust proof Siemens grey, structural RAL 7032, 6 mm thick fibre sheet for mounting MCB/MCCBs and other accessories, earth bus strip etc & connection with existing PVC/XLPE insulated cable with provision of joints Lugs gland etc all as specified & directed and consisting of the following including necessary PCC work for foundation excavation & earthwork etc complete, suitable for operation 3 Phase, 4 wire , 440 volt, 50 Hz AC system & consisting of following accessories complete all as specified & as directed.(Installed at Sub Stn -3):-(a) Aluminium bus bar 200 Amps rating, 4 Pole, 415 volts, TPN, colour coated with PVC/epoxy insulation & mounted insulator - 1 set of TPN (RYBN) (b) RYB Phase indicator LED type with protection MCB - 1 set 120 Sr. Item No. 15.098 Contd/....(c) CRCA sheet chamber for bus bar, MCCB/ MCB, Meter etc complete(d) MCCB 4 Pole with thermal magnetic release, 63 Amps TPN, 36 KA, 415 volt, AC, 50 Hz with necessary connection control wiring & accessories etc complete all as specifed & directed -1 No (incoming) (d) MCB, 415 Volts, 16 Amps, 10 KA, AC, 50 Hz, 3 Pole,TP with thermal & magnetic setting including necessary connections - 1 No (outgoing) (e) MCB TP, 415 Volts, 10 Amps, 10 KA, AC, 50 Hz, 3 Pole,TP with thermal & magnetic setting including necessary connections - 3No (outgoing) (g) MCB, , 20 Amps, 16 KA, AC, 50 Hz, 3 Pole,TP with thermal & magnetic setting including necessary connections - 1 No (outgoing) (h) MCB, 415 Volts, 32 Amps, 16 KA, AC, 50 Hz, 3 Pole,TP with thermal & magnetic setting including necessary-2nos(outgoing) (l) Digital multifunction meter with all electrical parameters like V, A, F, PF, KW, KVA, KWh, etc. - 1 No. (m) Control wiring with FR grade PVC insulated copper cable of suitable rating with necessary CTs & locking arrangement with DC panel lock Note :Panel shall be IP 65 Class CPRI approved and contractor shall submit CPRI Test Certificate to the Engineer-in-Charge (LT panel -04). 121 Supply, install, test and commisioning of factory fabricated LT panel, outdoor type mounted on 50 mm x 50 mm x 6 mm thick angle iron frame, cubicle modular made out of 3.15 mm thick CRCA sheet with epoxy powder coated after dip coated primer duly painted with rust proof Siemens gray structural RAL 7032 paint, 6 mm thick fibre sheet for mounting MCB/MCCBs and other accessories, earth bus strip etc & connection with existing PVC/XLPE insulated cable with provision of joints Lugs gland etc all as specified & directed and consisting of the following including necessary PCC work for foundation excavation & earthwork etc complete, suitable for operation 3 Phase, 4 wire , 440 volt, 50 Hz AC system & consisting of following accessories complete all as specified & as directed.(Installed at Sub Stn -3):- 122 Sr. Item No. 15.099 Contd/....(a) Aluminium bus bar 200 Amps rating, 4 Pole, 415 volts, TPN, colour coated with PVC/epoxy insulation & mounted insulator - 1 set of TPN (RYBN) (b) RYB Phase indicator LED type with protection MCB - 1 set (c) CRCA sheet chamber for bus bar, MCCB/ MCB, Meter etc complete(d) MCCB 4 Pole with thermal magnetic release, 100Amps TPN, 36 KA, 415 volt, AC, 50 Hz with necessary connection control wiring & accessories etc complete all as specifed & directed -1 No (incoming) (e) MCB TP, 415 Volts, 16 Amps, 10 KA, AC, 50 Hz, 3 Pole,TP with thermal & magnetic setting including necessary connections - 3No (outgoing) (g) MCB, , 20 Amps, 16 KA, AC, 50 Hz, 3 Pole,TP with thermal & magnetic setting including necessary connections - 1 No (outgoing) (h) MCB, 415 Volts, 32 Amps, 16 KA, AC, 50 Hz, 3 Pole,TP with thermal & magnetic setting including necessary-1nos(outgoing) (l) Digital multifunction meter with all electrical parameters like V, A, F, PF, KW, KVA, KWh, etc. - 1 No. (m) Control wiring with FR grade PVC insulated copper cable of suitable rating with necessary CTs & locking arrangement with DC panel lock Note :Panel shall be IP 65 Class CPRI approved and contractor shall submit CPRI Test Certificate to the Engineer-in-Charge (LT panel -05). 123 Supply, install, test and commisioning of factory fabricated LT panel, outdoor type mounted on 50 mm x 50 mm x 6 mm thick angle iron frame, cubicle modular made out of 3.15 mm thick CRCA sheet with epoxy powder coated after dip coated primer duly painted with rust proof Siemens gray structural RAL 7032 paint, 6 mm thick fibre sheet for mounting MCB/MCCBs and other accessories, earth bus strip etc & connection with existing PVC/XLPE insulated cable with provision of joints Lugs gland etc all as specified & directed and consisting of the following including necessary PCC work for foundation excavation & earthwork etc complete, suitable for operation 3 Phase, 4 wire , 440 volt, 50 Hz AC system & consisting of following accessories complete all as specified & as directed.(Installed at Sub Stn -3):- 124 Sr. Item No. 15.100 Contd/....(a) Aluminium bus bar 500 Amps rating, 4 Pole, 415 volts, TPN, colour coated with PVC/epoxy insulation & mounted insulator - 1 set of TPN (RYBN) (b) RYB Phase indicator LED type with protection MCB - 1 set (c) CRCA sheet chamber for bus bar, MCCB/ MCB, Meter (d) MCCB 4 Pole with thermal magnetic release, 320Amps TPN, 36 KA, 415 volt, AC, 50 Hz with necessary connection control wiring & accessories etc complete all as specifed & directed -1 No (incoming) (e) MCB TP, 415 Volts, 16 Amps, 10 KA, AC, 50 Hz, 3 Pole,TP with thermal & magnetic setting including necessary connections - 1No (outgoing) (g) MCB, 32Amps, 16 KA, AC, 50 Hz, 3 Pole,TP with thermal & magnetic setting including necessary connections - 3 No (outgoing) (h) MCB, 415 Volts, 250 Amps, 25 KA, AC, 50 Hz, 3 Pole,TP with thermal & magnetic setting including necessary-1nos(outgoing) (l) Digital multifunction meter with all electrical parameters like V, A, F, PF, KW, KVA, KWh, etc. - 1 No. (m) Control wiring with FR grade PVC insulated copper cable of suitable rating with necessary CTs & locking arrangement with DC panel lock Note :Panel shall be IP 65 Class CPRI approved and contractor shall submit CPRI Test Certificate to the Engineer-in-Charge (LT panel -06 FOR FIRE FIGHTING). 125 Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure complete all as specified and as directed 126 Supply and installation of 11 KV, single phase, out door oil cooledCT/PT combination with CT of ratio 400/5 Amp, class 1.0 / 5P10, burden 15 VA and PT of ratio 11 KV/rt3/110V/rt3/110V/ rt3, class 0.5-3, Burden 50 VA - 50 VA including other accessories & connecting complete all as specified and as directed 127 Supply Installation,testing & comissioning ofintregral LED 4ft luminaire of CRCA / extruded aluminium housing and PC diffuser (Diffuser-Non yellowing type). The luminaire should have a 20 Watt LED with colour consistency SDCM< 5,CRI> 80 and colour temperature - 4000 to 6500K, Luminaire shall be desihned to emit at least 2000 nominal lumens at a system efficacy of at-least 120 lumen/watt, power consumption should not be more than 20W (+5%). the life of fixture (including Driver): 50000 burning Hrs.@ L70B50 Lumen maintenance @ design ambient temp 50 deg C. The electronic driver used shall have a power factor >0.95 and THD < 10% suitable for an operating voltage range of 150-270V AC current Ripple<5% internal surge protection should be minimum 2.5KV, electrical insulation class should be Class I &driver should be of class B serviceablility.The luminaire should be at least IP 20 & IK02 rated. The luminaire driver shall be of the same make/manufacturer as that of LED luminaires. Luminaire manufacturer must have in house NABL accredited lab conduct LM79, type test as per IS10322 & FAT before dispatch as per IS 10322. the contractor must submit the NABL accredition certificate for luminaire manufacturer along along with sample approval. the LED Luminaire & Its driver both should be BIS registered successful bidder shall submit the following reports before supply of sample approval LM79 issued by NABL accrediated lab, LM80 issued by LED manufacturer type test certificate for luminaire as issued by NABL accrediate lab, RoHS compliance issued by LED luminaire manufacturer, BIS certificate for LED Luminaire & Driver, the quoated rate shall deem to be inclusive of replacement warranty on all LED luminaries & accordingly the contractor shall submit OEM certificate to GE regarding same before placing the Order complete all as specified and directed. 128 Supply Installation, testing & comissioning of Integral / batten LED 2ft, 10 watt 220 V, luminaire made of CRCA/ extruded aluminium housing and PC diffuser (Diffuser-Non yellowing type). The luminaire should have a LEDs with colour consistency SDCM ≤ 5, CRI ≥ 80 and CCT of 6500K. Luminaire shall be designed to emit at least minimum 2000 system lumens at a system efficacy of at-least 120 lumen/watt. Power consumption should not be more than 10W (± 5%). The Life of fixture (Including Driver):50000 burning Hrs. @ L70B50 Lumen maintenance @ design ambient temp 45 deg C. The electronic driver used shall have a power factor 0.95 and THD ≤10%, suitable for an operating voltage range of 140-270V AC, Current Ripple ≤ 5%, Internal surge protection should be minimum 2 KV, electrical insulation class should be Class I & driver should be of Class B serviceability. The luminaire shall be IP20 & IK02 rated.The luminaire driver shall be of the same make/manufacturer as that of LED luminaires. Luminaire manufacturer must have in house NABL accredited lab conduct LM79, type test as per IS10322 & FAT before dispatch as per IS 10322. the contractor must submit the NABL accredition certificate for luminaire manufacturer along along with sample approval. the LED Luminaire & Its driver both should be BIS registered successful bidder shall submit the following reports before supply of sample approval LM79 issued by NABL accrediated lab, LM80 issued by LED manufacturer type test certificate for luminaire as issued by NABL accrediate lab, RoHS compliance issued by LED luminaire manufacturer, BIS certificate for LED Luminaire & Driver, the quoated rate shall deem to be inclusive of replacement warranty on all LED luminaries & accordingly the contractor shall submit OEM certificate to GE regarding same before placing the Order complete all as specified and directed. 129 Supply & Fix LED building security light fitting of minimum capacity 25 Watt, including LED lamp complete with body robust, corrosion resistant, superior finish and without any cracks or through holes, made in a single piece, high pressure die castaluminium alloy, monolithic construction totally enclosed, dust and water proof with minimum IP65 protection as per IS-10322-1982(Part-I) with latest amendments and input voltage range 140-300 VAC, frequency 50-60Hz, P.F should be more than 0.9 with THD(I) less than 10%, cool white color and. Fitting should be provided with min 4 KV surge protection, constant current constant voltage driver, high voltage withstanding capacity upto 300 VAC and also have double phase protection, no load, open circuit and short circuit protection, Light fitting suitable for ambient temperature from minus 10 degree Centigrade to 50 degree Centigrade and humidity level 10% to 90% RH. Covers should be polycarbonate/toughened glass to ensure minimum IP65 degree protection. The lumen output shall not be less than be 110 lumens per watt, life should not less than 40Khr, color index 6000K and must be certified by the relevant test report Fitting should fixed on pole using and including 1.2m long 32/40mm dia GI pipe light grade bend to shape and fixed using two nos clamps fabricated using MS Flat iron 40x5mm including necessary nut bolts and washers and making electrical connection using 1.5sqmm, 3 core multi-stranded copper conductor PVC insulated and over all PVC sheathed cable form light fitting to junction box complete all as specified and directed . 130 Supply and fixing MCB DB 4 way TPN sheet metal enclosure suitable for fixing MCB of appropriate capacity as incomer and SP for outgoing ,415 volts, 50 Hz, with IP-43 protection, double door with 100 Amps standard bus bar of suitable size and common neutral link all enclosed in standard sheet flush mounting complete all as specified and directed.(Note: (i) MCB SP/MCB shall be measured and paid seperately under appropriate items of this schedule.(ii) Copper thimble shall be used for connection of cable. 131 Supply and fixing MCB Distribution board, 240 volts single pole andneutral,double door, sheet steel, enclosure powder coated with 100 Amps rated busbar with neutral link, 12 ways, fixed on wall duly grouted in solid block wall or on wooden board with electrical connection complete all as specified and directed. 132 Supply and fixing MCB Distribution board, 240 volts single pole andneutral,double door, sheet steel, enclosure powder coated with 100 Amps rated busbar with neutral link, 10 ways, fixed on wall duly grouted in solid block wall or on wooden board with electrical connection complete all as specified and directed. 133 Supply and fixing MCB Distribution board , 240 volts single pole andneutral ,double door, sheet steel, enclosure powder coated with 100 Amps rated busbar with neutral link, 8 ways , fixed on wall duly grouted in solid block wall or on wooden board with electrical connection complete all as specified and directed. 134 Supply and fixing MCB Distribution board , 240 volts single pole andneutral ,double door, sheet steel, enclosure powder coated with 100 Amps rated busbar with neutral link, 4 ways , fixed on wall duly grouted in solid block wall or on wooden board with electrical connection complete all as specified and directed. 135 Supply and fixing blanking plate suitable for fixing in MCB DB complete all as specifified and directed. 136 Material & Labour for submain wiring with PVC insulated unsheathed copper conductor multi stranded FRLS type 1100V grade 2 x 2.5 sqmm completedrawn in new PVC concealed conduitand its accessories along with 1x 2.5 sqmm PVC insulated unsheathed copper conductor multi strandedFRLS type cable for continuous earth wire and duly connected to common earth dollycomplete all as specified and directedNote :- Cutting chases for concealed sub main wiring for the following points and making good in cement mortar is deemed included in unit rate 137 Material & Labour for submain wiring with PVC insulated unsheathed copper conductor multi stranded FRLS type 1100V grade 2 x 6 sqmm completedrawn in new PVC concealed conduitand its accessories along with 1x 6 sqmm PVC insulated unsheathed copper conductor multi strandedFRLS type cable for continuous earth wire and duly connected to common earth dollycomplete all as specified and directedNote :- Cutting chases for concealed sub main wiring for the following points and making good in cement mortar is deemed included in unit rate 138 Material & Labour for submain wiring with PVC insulated unsheathed copper conductor multi stranded FRLS type 1100V grade 4 x 6 sqmm completedrawn in new PVC concealed conduitand its accessories along with 1x 6 sqmm PVC insulated unsheathed copper conductor multi strandedFRLS type cable for continuous earth wire and duly connected to common earth dollycomplete all as specified and directedNote :- Cutting chases for concealed sub main wiring for the following points and making good in cement mortar is deemed included in unit rate 139 Supply and installation of High intensity, energy saving, long range, directional controlled, manually swiveble, LED search light, beam range >700 meters, 1x300W in multi circuit SMD LED, Effciency > 100 lm/w, PF>0.95, CCT 5500K - 6500K, Optical grade PMMA-PC lens, anti-UVoxidation, narrow beam 8 degree, die cast LM6 body with air fins, fully powder coated, working voltage 100 - 300v, 50Hz, constant current, reflector / lens efficiency > 90%, minimum lux level at 10meter - 6000 with circle of approx 500mm,IP-66, confirming to LM79, LM80, IS:10322 / BIS. The above search - light to be installed on UDCA stand (1 Meter above from roof) & the operating lever (Hydraulic) of UDCA shall be in shoulder height to enable to rotate the luminaire easily frominside of the watch tower at 3600 horizontally & 450 vertically with built-in locking knob. All bushes of UDCA shall be made by gun metal, hardware shall be in S.S. and other metal parts would be Zinc electroplated / powder coated for outdoor installations and having 3 fountain loles at bottom alongwith complete stand and moving mechanism complete all as specified and as directed. 140 Material & Labour forconcealed Point wiring with 1.5 Sqmm (nominal cross-sectional area) FRLSH PVC insulated & unsheathed 1100 volts grade multi stranded copper conductor single core cable drawn through in and including stove enamelled steel ERW conduit of adequate size with and including flameproof flexible metallic conduit required for connecting flame proof light fittings/ switches/socket/DBs for insertion of wiring, with all flame proof conduit fittings and accessories such as bends, tees, reducers, elbows, junction boxes etc (all flameproof), and including Polytetrafluoroethylene (PTFE) (Teaflon) type sealing proof joint etc complete including FRLSH PVC insulated & unsheathed single core multistranded copper conductor cable of size 1.5 Sqmm green in colour as earth continuity conductor connected to common earth and earth dolly for Five light point controlled by one, one way flame proof rotary switch. Note: (all Control switches and sockets to be provided outside on the wall of building). 141 Material & Labour forconcealed Point wiring with 1.5 Sqmm (nominal cross-sectional area) FRLSH PVC insulated & unsheathed 1100 volts grade multi stranded copper conductor single core cable drawn through in and including stove enamelled steel ERW conduit of adequate size with and including flameproof flexible metallic conduit required for connecting flame proof light fittings/ switches/socket/DBs for insertion of wiring, with all flame proof conduit fittings and accessories such as bends, tees, reducers, elbows, junction boxes etc (all flameproof), and including Polytetrafluoroethylene (PTFE) (Teaflon) type sealing proof joint etc complete including FRLSH PVC insulated & unsheathed single core multistranded copper conductor cable of size 1.5 Sqmm green in colour as earth continuity conductor connected to common earth and earth dolly for Four light point controlled by one, one way flame proof rotary switch. Note: (all Controll switches and sockets to be provided outside on the wall of building). 142 Material & Labour forconcealed Point wiring with 1.5 Sqmm (nominal cross-sectional area) FRLSH PVC insulated & unsheathed 1100 volts grade multi stranded copper conductor single core cable drawn through in and including stove enamelled steel ERW conduit of adequate size with and including flameproof flexible metallic conduit required for connecting flame proof light fittings/ switches/socket/DBs for insertion of wiring,with all flame proof conduit fittings and accessories such as bends, tees, reducers, elbows, junction boxes etc (all flameproof), and including Polytetrafluoroethylene (PTFE) (Teaflon) type sealing proof joint etc complete including FRLSH PVC insulated & unsheathed single core multistranded copper conductor cable of size 1.5 Sqmm green in colour as earth continuity conductor connected to common earth and earth dolly for three light point controlled by one, one way flame proof rotary switch. Note: (all Controll switches and sockets to be provided outside on the wall of building). 143 Material & Labour forconcealed Point wiring with 2.5 Sqmm (nominal cross-sectional area) FRLSH PVC insulated & unsheathed 1100 volts grade multi stranded copper conductor single core cable drawn through in and including stove enamelled steel ERW conduit of adequate size with and including flameproof flexible metallic conduit required for connecting flame proof light fittings/ switches/socket/DBs for insertion of wiring,with all flame proof conduit fittings and accessories such as bends, tees, reducers, elbows, junction boxes etc (all flameproof) , and including Polytetrafluoroethylene (PTFE) (Teaflon) type sealing proof joint etc complete including FRLSH PVC insulated & unsheathed single core multistranded copper conductor cable of size 2.5 Sqmm green in colour as earth continuity conductor connected to common earth and earth dolly for flameproof , one independent Plug in switch socket 3 pin (2P+E) 16 Amps. 144 Supply and Fixing Flameproof rotary switch weatherproof 16 Amps, single pole with separate terminal chamber made in die cast Aluminium alloy LM6 with IP66 ingress protection with all stainless steel and painted with epoxy based powder coated structured paint having temp class T6 certified by CIMFR (Central Institute of Mining and Fuel Research) & PESO (Petrolium and Explosives Safety Organization) suitable for 230 Volt, 50 Hz complete all as specified and as directed.NOTE:5/4 Nos flame proof lights shall be controlled by one flame proof rotary switch. 145 Supply and Fixing Flameproof switch socket & plug combined, weatherproof 16/20 Amps DP with 3 pin plug top with separate terminal chamber made in die cast Aluminium alloy LM6 with IP66 ingress protection with all stainless steel and painted with epoxy based powder coated structured paint having temp class T6 certified by CIMFR (Central Institute of Mining and Fuel Research) & PESO (Petrolium and Explosives Safety Organization) complete all as specified and as directed. 146 Supply and Fixing Flameproof / weather proof MCB Distribution board SPN 12 way made in die cast Aluminium alloy LM6 with IP65 ingress protection with all stainless steel and painted with epoxy based powder coated structured paint having temp class T6 certified by CIMFR (Central Institute of Mining and Fuel Research) & PESO (Petrolium and Explosives Safety Organization) complete with and including internal bus bar & wiring up to terminal complete all as specified and as directed. 147 Supply and Fixing Flameproof / weather proof MCB Distribution board SPN 10 way made in die cast Aluminium alloy LM6 with IP65 ingress protection with all stainless steel and painted with epoxy based powder coated structured paint having temp class T6 certified by CIMFR (Central Institute of Mining and Fuel Research) & PESO (Petrolium and Explosives Safety Organization) complete with and including internal bus bar & wiring up to terminal complete all as specified and as directed. 148 Supply & Fix Surge protection device (SPD) single phase and neutral, 16 KA, T1+T2- limp 8 kA per pole complete fixed in distribution board and making connections complete all as specified and directed. (for flameproof SPN DBs). 149 Supply and Fixing Flameproof, weatherproof LED wellglass lightcapacity not less than 30Watt having flying saucer design with 120 degree beam angle lens , 65000 K with 120 Lumen/watt & LED driver made in die cast Aluminium alloy LM6 with IP65 ingress protection with all stainless steel and painted with epoxy based powder coated structured paint having temp class T6 certified by CIMFR (Central Institute of Mining and Fuel Research) & PESO (Petrolium and Explosives Safety Organization) complete all as specified and as directed. 150 Supply and Fixing Flameproof, weatherproof LED tube light 1x18/20 watt 4 feet including tube rode 18/20 watt and cable entries and stopping plugs, made in die cast Aluminium alloy LM6 with IP65 ingress protection with all stainless steel and painted with epoxy based powder coated structured paint shade as per IS:5-631 having temp class T6 certified by CIMFR (Central Institute of Mining and Fuel Research) & PESO (Petrolium and Explosives Safety Organization) complete all as specified and as directed. 151 Supply & laying 100 micron (0.1 mm) sizecopper strip suitable for anti static flooringof explosive stores URP or , ESH type where directed &connected to main earth lead complete all as specified.

Key Value

Document Fees
INR 3000 /-
EMD
INR 1500000.0 /-
Tender Value
INR 106.25 Crore /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Notice 0 KB
Click here to download tender document Tender Document 0 KB
Click here to download tender document Tender Document 0 KB
Click here to download tender document Tender Document 0 KB
Click here to download tender document Tender Document 0 KB
Click here to download tender document Tender Document 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail