}

Tender For Repair/Replacement Of Lt Ug Cable, Feeder Pillar Box, Oh Lines And Allied Works Of Ph No 01 Area Under Ge Panagarh, Bankura-West Bengal

Statutory Bodies & Commissions/Committees has published Tender For Repair/Replacement Of Lt Ug Cable, Feeder Pillar Box, Oh Lines And Allied Works Of Ph No 01 Area Under Ge Panagarh. Submission Date for this Tender is 30-09-2024. Cushioning Supplies Tenders in Bankura West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

45251973
Tender For Repair/Replacement Of Lt Ug Cable, Feeder Pillar Box, Oh Lines And Allied Works Of Ph No 01 Area Under Ge Panagarh
Open Tender
Indian
West Bengal
Bankura
30-09-2024

Tender Documents

Tender Details

Tender For Repair/Replacement Of Lt Ug Cable, Feeder Pillar Box, Oh Lines And Allied Works Of Ph No 01 Area Under Ge Panagarh; 1 Disconnecting and taking out existing defective LT cables alongwith old size bricks etc of following sizes and setting aside for further disposal as diected (Note: Excavation & earthwork will be measured & paid & separately) 2 (a) 4Core 10 to 3.5 Core 35 sqmm 3 (b) 3.5 Core 70 to 95 sqmm 4 (c)3.5 Core 120 to 150sqmm 5 (d) 3.5 Core 185 to 400 sqmm 6 (e) 2 Core 10 Sqmm 7 M&L for dismantling of LT Poles 8.5mtr/9mtr including earth excavation upto 1.65 mtr for Hard dense soil, PCC demolition from foundation to upto palantimg depth and PCC coping etc, dismantling of existing accessories of Poles.i.e. Street Light alongwith Poles , PVC Junction Boxes, PVC cables of any size from Junction Boxes to Street Light etc complete all as speified and directed 8 Supply & laying in replacement including testing & commissioning ofcable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of following sizes:-Note - Excavation / earthwork, cable protection covers & sand cushioning will be measured and paid separately under respective item of sch A 9 (a) 3.5 Core 400 Sqmm 10 (b) 3.5 Core 300 Sqmm 11 (c) 3.5 Core 240 Sqmm 12 (d) 3.5 Core 185 Sqmm 13 (e) 3.5 Core 150 Sqmm 14 (f) 3.5 Core 120 Sqmm 15 (g) 3.5 Core 95 Sqmm 16 (h) 3.5 Core 70 Sqmm 17 (j) 3.5 Core 50 Sqmm 18 (k) 3.5 Core 35 Sqmm 19 (l) 4 Core 25 Sqmm 20 (m) 4 Core 16 Sqmm 21 (n) 4 Core 10 Sqmm 22 (o) 2 Core 10 Sqmm 23 Relaying serviceable LT UG cable of follwing sizescomplete all as specified and directed.Note:Excavation / earthwork, cable protection covers & sand cushioning will be measured and paid separately under respective item of sch A 24 (a) 3.5 Core 400 Sqmm 25 (b) 3.5 Core 300 Sqmm 26 (c) 3.5 Core 240 Sqmm 27 (d) 3.5 Core 185 Sqmm 28 (e) 3.5 Core 150 Sqmm 29 (f) 3.5 Core 120 Sqmm 30 (g) 3.5 Core 95 Sqmm 31 (h) 3.5 Core 70 Sqmm 32 (j) 3.5 Core 50 Sqmm 33 (k) 3.5 Core 35 Sqmm 34 (m) 4 Core 25 Sqmm 35 (n) 4 core 10 -16 Sqmm 36 (o) 2 Core 10 Sqmm 37 Excavation in trenches in Hard/Dense soil, n.exc 1.5m wide and n.exc 1.5 m depth and getting out for foundation of pole, stay, laying of cable and pipe etc complete all as specified and directed. 38 Returning and filling in, including spreading and well ramming in layers n exc 25 cm complete all as specified and directed. 39 Removing excavated material a distance n.exc 50 m & depositing where directed at a level n. exc 1.5 m above the starting point complete all as specified and directed. 40 M&L for dry sand cushioing to under ground cable in trenches incl spreading, leveling and hand punning complete all as specified and directed.Note : For measurement purpose punned thickness shall be considered. 41 Taking out old unserviceable bricks from the trench obtain during excavation for LT cables and staking aside for reuse or disposal etc complete all as specified and directed. 42 Laying only serviceable bricks for protection of cable obtained from item No 9 43 Supply and laying common fly ashbuilding sub class B old size bricks, laid in right angle over the cable, complete all as specified. 44 Supply and lay G.I pipe light grade in replacement with all fittings required for protection of under ground cable of following sizes:- 45 (a) 150 mm 46 (b) 100 mm 47 (c) 80 mm 48 (d) 50 mm 49 (e) 40 mm 50 M&L for Floor/PCC/Footpath cutting through existing PCC/floor/Footpath approx size width 15cm X 60cmdepth as required for Realying/Laying of cable/ pipe etc and making good with and including earthwork and necessary excavation, complete material required to match with the existing one or with PCC 1:2:4 type B1 complete all as specified and as directed by Engr-in-Charge. 51 M&L for drilling hole horizontally under road / pavement /hardstanding by trenchless method using machine suitable and including required size of HDPE pipe/GI Pipe etccomplete all as specified and directed.Note:- Pipes shall be measured and paid seperately 52 Supply and lay High density polyethylene pipes (HDPE) of pressure rating 6 kgf/cm2 laid in trenches:- 53 (a) 150 mm 54 (b) 100 mm 55 (c) 50 mm 56 (d) 40 mm 57 M&L for Straight through LT cable heat shirnkablejointing kit suitable forLT UG of following sizes cable complete 58 (a) 10 Sqmm 4 Core/2 Core to 16 Sqmm 4 Core 59 (b) 25 Sqmm 4 Core to 50 Sqmm 3.5 Core 60 (c) 70 Sqmm 3.5 Core to 120 Sqmm 3.5 Core 61 (d) 150 Sqmm 3.5 Core to 185 Sqmm 3.5 Core 62 (e) 240 Sqmm 3.5 Core to 300 Sqmm 3.5 Core 63 (f) 400 Sqmm 3.5 Core 64 Labour for restretching/tightening the existing LT overhead conductors & GI earth wire mounted on insulators of any type on poles manually or by mechanical means to the extent of permissible sag and tension and binding with steel wires of appropriate size complete having 5 to 7 conductors per span of approx 35-40 mtr length.All as specified and directed by Engr-in-Charge. 65 M&Lin replacementaluminium conductor steel reinforced fixing on the over head LT pole with the help of aluminium tapes/ binding wire, taking down and complete all as specified as directed by the Engr-in-Charge 66 M&Lin replacementgalvanised steel wire 4mm diafixing on the over head LT pole with the help of aluminium tapes/ binding wire, taking down and complete all as specified as directed by th Engr-in-Charge 67 Pruning/trimming of branches of trees interfering or overhanging electrical overhead lines in such a way to have a clearance of not be less than 2 mtrs from the outermost conductors on both side complete all as specified and directed by Engr-in-Charge (Span of conductor shall be measured from insulator to insulator without allowance for overlapping) All as specified and directed by Engr-in-Charge. 68 Pin type porcelain vitreous white brown or green insulator including one galvanised mild steel spindle two galvanised iron washers and one galvanised iron nut 100 mm height 65 mm dia 1100 volts grade including taking down complete all as specified and directed Make:BHEL/National 69 Shackle type porcelain vitreous white brown or green insulator including one galvanised mild steel straps washers insulators bolts washers and nut as under100 mm height 115 mm dia 1100 volts grade including taking down Engr-in-Charge Make:BHEL/National 70 M&Lfor plain concrete cement PCC 1:4:8 type D2 for base and foundation (using 40mm graded coarse aggregate) for foundation of poles including necessary form work complete all as speified and directed 71 M&Lfor PCCPCC 1:3:6 type C1 (using 20 mm graded aggregate) for coping of poles including fair finishing the exposed surfaces even and smooth without using extra cement including necessary formwork complete all as speified and directed 72 M&Lin replacementcross arms bracing supports clamps and back plate fabricated from structuralsteel sections including nuts bolts washers welding bending cold or hot drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat one umder coat and one finishing coat of paint including taking down 73 M&Lin replacementsteel tubular swaged poles complete with cast iron base plate finial taper plug bolts nuts & screws as specified type SP-31 9 mtrs long complete all as specified and directed. 74 M&Lfor preparation of existing surface of steel tubular pole by srapping down peeled off old paint, cleaning etcof length 8.5/9/11 mtrs and cross arms etc and applying one coat of aluminium coatpaint including rewriting pole Nos as directed with black paint complete all as specified and directed by Engr-in-Charge. 75 Dismantling the existing Air Circuit Breaker 630 Amps 3 phase 415 volts ACsupply including disconnection of electrical and opening the system.Servicing the complete ACB including reassembling the same after repairing / servicing, testing and commissioning etc. servicing / maintenance and calibration & testing of relay any type by injecting fault currentwith testing equipmente.g.Earth fault relay/Over current relay,etc ofbreakers installed at different power distribution sub stns. The fault level setting of these relays shall be in such a way that individual breaker will activate / trip to arrest the fault in local circuit and fault will not travel to main breakers all as specified and directed. 76 M&L for fixing of MCCBs in replacement of 63 Amps,4 Pole, 415 Volts thermal & magnetic adjustable type 0.8 to 1In, Magnetic Adjustable 5 to 10In, Breaking capacity 16 kA, 4 Pole, Ics= 100% Icu, with spreader links and Phase barriers complete all as specified and directed. 77 M&L for fixing of MCCBs in replacementof 100 Amps, 4 Pole, 415 Volts thermal & magnetic adjustable type 0.8 to 1In, Magnetic Adjustable 5 to 10In, Breaking capacity 16 kA, 4 Pole, Ics= 100% Icu, with spreader links and Phase barriers complete all as specified and directed. 78 M&L for fixing of MCCBs in replacementof 125 Amps,4 Pole, 415 Volts thermal & magnetic adjustable type 0.8 to 1In, Magnetic Adjustable 5 to 10In, Breaking capacity 16 kA, 4 Pole, Ics= 100% Icu, with spreader links and Phase barriers complete all as specified and directed. 79 M&L for fixing of MCCBs in replacementof 160 Amps, 4 Pole, 415 Volts thermal & magnetic adjustable type 0.8 to 1In, Magnetic Adjustable 5 to 10In, Breaking capacity 36 kA, 4 Pole, Ics= 100% Icu, with spreader links and Phase barriers complete all as specified and directed. 80 M&L for fixing of MCCBs in replacementof 200 Amps,4 Pole, 415 Volts thermal & magnetic adjustable type 0.8 to 1In, Magnetic Adjustable 5 to 10In, Breaking capacity 36 kA, 4 Pole, Ics= 100% Icu, with spreader links and Phase barriers complete all as specified and directed. 81 M&L for fixing of MCCBs in replacementof 250 Amps, 4 Pole, 415 Volts thermal & magnetic adjustable type 0.8 to 1In, Magnetic Adjustable 5 to 10In, Breaking capacity 36 kA, 4 Pole, Ics= 100% Icu, with spreader links and Phase barriers complete all as specified and directed. 82 M&L for fixing of MCCBs in replacementof 400 Amps, 4 Pole, 415 Volts thermal & magnetic adjustable type 0.8 to 1In, Magnetic Adjustable 5 to 10In, Breaking capacity 36 kA, 4 Pole, Ics= 100% Icu, with spreader links and Phase barriers complete all as specified and directed. 83 M&L for fixing of MCCBs in replacement of 63 Amps,3 Pole, 415 Volts thermal & magnetic adjustable type 0.8 to 1In, Magnetic Adjustable 5 to 10In, Breaking capacity 16 kA, 4 Pole, Ics= 100% Icu, with spreader links and Phase barriers complete all as specified and directed. 84 M&L for fixing of MCCBs in replacementof 100 Amps, 3 Pole, 415 Volts thermal & magnetic adjustable type 0.8 to 1In, Magnetic Adjustable 5 to 10In, Breaking capacity 16 kA, 4 Pole, Ics= 100% Icu, with spreader links and Phase barriers complete all as specified and directed. 85 M&L for fixing of MCCBs in replacementof 125 Amps,3 Pole, 415 Volts thermal & magnetic adjustable type 0.8 to 1In, Magnetic Adjustable 5 to 10In, Breaking capacity 16 kA, 4 PoleIcs= 100% Icu, with spreader links and Phase barriers complete all as specified and directed. 86 M&L for fixing of MCCBs in replacementof 160 Amps, 3 Pole, 415 Volts thermal & magnetic adjustable type 0.8 to 1In, Magnetic Adjustable 5 to 10In, Breaking capacity 36 kA, 4 Pole, Ics= 100% Icu, with spreader links and Phase barriers complete all as specified and directed. 87 M&L for fixing of MCCBs in replacementof 200 Amps,3 Pole, 415 Volts thermal & magnetic adjustable type 0.8 to 1In, Magnetic Adjustable 5 to 10In, Breaking capacity 36 kA, 4 Pole, Ics= 100% Icu, with spreader links and Phase barriers complete all as specified and directed. 88 Dismantling of Old Unserviceable/Burnt MCCBs 4 pole /3 Pole of any capacity complete all as specified and directed. 89 M&L for earthing complete with galvanized steel earth plate electrode 600 X 600 X 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.50 m deep below normal ground level, connected to galvanized iron strip 32X6mm by means of bolts, nuts and washers of galvanised iron or steel all as shown in earth plate No 3 of MES schedule 1991 part – I connected to machinery/equipment for Timer Panel etc. as required 32x6 mm dia galvanized iron with 40mm GI light Grade pipe for protection including necessary excavation and earth work, concrete pit & chamber in PCC 1:2:4 type B1 & pit cover 75mm thick in PCC 1:2:4 type B1 dully reinforced with 6mm dia bar @ 150 c/c both ways including with lifting handle and Earth lead and 20mm bore GI watering pipe medium grade,etc. complete all as specified and directed. 90 All as per item No 42.00 mentioned above but 4mm dia GI earth wire as Earth electrode complete all as specified and directed. 91 M&L for fixing only existing LT street light Pole 8.5mtr/9mtr including earth excavation upto 1.65 mtr for Hard dense soil, PCC 1:4:8 type D2 40mm graded foundation .9mX.9mX.15m and .6mX.6m X 1.5m upto planting depth, PCC coping 1:3:6 type C120mm graded aggregatefrom ground level to 30m height and 15m thick around the pole etccomplete all as specified and directed. 92 M&L for refixing the Street Lights alongwith its all accessories i.e. Street light pole 1.2 mtr of 50mm dia , existing PVC cable connection from Junction Box to Street Light Pole etc, refixing of PVC Junction boxes complete all as specified and directed 93 M&Lfor preparation of existing surface of LT Panel by srapping down peeled off old paint, cleaning etcof size upto 900mm X 400mm X 900mm (L X W X H) and applying primer on cleaned surface and applying Two coat of Siemens Grey Paintand Black paint on Angle Iron etc complete all as specified and directed by Engr-in-Charge. 94 M&Lfor preparation of existing surface of LT Panel by srapping down peeled off old paint, cleaning etcof size upto 1000mm X 400mm X 1000mm (L X W X H) and applying primer on cleaned surface and applying Two coat of Siemens Grey Paintand Black paint on Angle Iron etc complete all as specified and directed by Engr-in-Charge. 95 M&Lfor preparation of existing surface of LT Panel by srapping down peeled off old paint, cleaning etcof size upto 1200mm X 400mm X 1200mm (L X W X H) and applying primer on cleaned surface and applying Two coat of Siemens Grey Paintand Black paint on Angle Iron etc complete all as specified and directed by Engr-in-Charge. 96 S&F LT Busbar Box, made of CRCA Sheet double door outdoor type factory made and assembled of size not less than 750x400x900(LXBXH) with 3.15mm thick CRCA Sheet , shall be provided 04 Nos Busbar of 400 Amp 50 KA and shall also be provided 4 Nos 40x40x5mm thick angle iron supports up to each 0.6 Mt height duly painted with anti corrosive black paint and grouted in PCC 1:3:6 at suitable depth/floor mounting with fasteners, nut bolts etc as per site requirement complete all as directed by the Engr-in-Charge. 97 S&F LT Busbar Box, made of CRCA Sheet double door outdoor type factory made and assembled of size not less than 450x150x450(LXBXH) with 3.15mm thick CRCA Sheet , shall be provided 04 Nos Busbar of 400 Amp 50 KA and shall also be provided 4 Nos 40x40x5mm thick angle iron supports up to each 0.6 Mt height duly painted with anti corrosive black paint and grouted in PCC 1:3:6 at suitable depth/floor mounting with fasteners, nut bolts etc as per site requirement complete all as directed by the Engr-in-Charge. 98 S&F testing, commissioning and installation in replacement Multifunction Meter LED ,Accuracy Class 1, with RS 485 Parameters V,A,F,PF,kW,kVA,kVAR,kWh,kVAh,kVARh,Runhours,On Hours, Phase angle, Interrupts,THD, Events(High-Low), Neutral Current including suitable size of CTs etc complete all as specified and directed.Make: Legrand/L&T/Schneider 99 S&F in repairs flexible flat PVC insulated FRLS PVC sheathed copper couductor stranded submersible cable cores 1100 volt grade 25 Sqmm single core including jointing material and connection work, complete all as specified and as directed by Engr-in-Charge. 100 S&F in repairs, flexible flat PVC insulated FRLS PVC sheathed copper couductor stranded submersible cable cores 1100 volt grade 16 Sqmm single core including jointing material and connection work, complete all as specified and as directed by Engr-in-Charge. 101 S&F in repairs flexible flat PVC insulated FRLS PVC sheathed copper couductor stranded submersible cable cores 1100 volt grade 35 Sqmm single core including jointing material and connection work, complete all as specified and as directed by Engr-in-Charge. 102 S&F in repairs flexible flat PVC insulated FRLS PVC sheathed copper couductor stranded submersible cable cores 1100 volt grade 50 Sqmm single core including jointing material and connection work, complete all as specified and as directed by Engr-in-Charge. 103 S&F galvanised or codmium plated high tensile Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm longof 5 to 10mm dia of neck complete all as specified and as directed 104 All as per item No 56.00 mentioned above but n exc 11 to 15mm dia of neck complete all as specified and as directed 105 All as per item No 56.00 mentioned above but n exc 16 to 20mm dia of neck complete all as specified and as directed 106 M&L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32x6mm galvanised iron strip complete all as specified and as directed 107 S&F 415V 10KA C curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the DB complete with connection testing and commissioning of capacity TPN 16 To 32 AMP complete all as specified and as directed 108 S&F 415V 10KA C curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the DB complete with connection testing and commissioning of capacity TPN 40 To 63 AMP complete all as specified and as directed

Key Value

Document Fees
INR 500 /-
EMD
INR 80000.0 /-
Tender Value
INR 40 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Notice 0 KB
Click here to download tender document Tender Document 0 KB
Click here to download tender document Tender Document 0 KB
Click here to download tender document Tender Document 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail