Tender For Repair To Pump Motor Sets, Starter, Valves, Cables, Panels And Connected Works At Pump House At Mil Stn Kanasar, kanasar-Rajasthan

Statutory Bodies & Commissions/Committees has published Tender For Repair To Pump Motor Sets, Starter, Valves, Cables, Panels And Connected Works At Pump House At Mil Stn Kanasar. Submission Date for this Tender is 05-10-2024. Footwears Tenders in kanasar Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

45234835
Tender For Repair To Pump Motor Sets, Starter, Valves, Cables, Panels And Connected Works At Pump House At Mil Stn Kanasar
Open Tender
Indian
Rajasthan
Kanasar
05-10-2024

Tender Documents

Tender Details

Tender For Repair To Pump Motor Sets, Starter, Valves, Cables, Panels And Connected Works At Pump House At Mil Stn Kanasar- 1 M&L for disconnecting suction/delivery lines and coupling, taking down from foundation base frame, opening including dismantling of centrifugal pump set of capacity 10 HP and replacement of worn out spare part and re-assembling and installing, commissioning & testing in same location complete all as specified & as directed.Note : (i) The spare parts required to be replaced shall be measured and paid for separately as Supply only under the relevant item of this Schedule.(ii) Unit rate shall be deemed to include for all minor spares/extras. 2 Supply only the following spare parts for centrifugal pump set of capacity 10 HP against serial item No. 1.00 here-in-before as per existing make, complete all as specified & as directed.Note : All spare parts shall be fixed in the pumps only after prior inspection & approval of AGE. 3 SS Pump shaft. 4 CI Impeller complete with impeller key. 5 Shaft sleeve bronze with locking screw & lock nut. 6 Wearing ring (DE &NDE) CI 7 Set ofO ring 8 CI gland cap with eye bolt complete. 9 GM gland sleeve bush. 10 M&L for disconnecting suction/delivery lines and coupling, taking down from foundation base frame, opening including dismantling of centrifugal pump set of capacity 20 HP and replacement of worn out spare part and re-assembling and installing, commissioning & testing in same location complete all as specified & as directed.Note : (i) The spare parts required to be replaced shall be measured and paid for separately as Supply only under the relevant item of this Schedule.(ii) Unit rate shall be deemed to include for all minor spares/extras. 11 Supply only the following spare parts for centrifugal pump set of capacity 20 HP against serial item No. 3.00 here-in-before as per existing make, complete all as specified & as directed.Note : All spare parts shall be fixed in the pumps only after prior inspection & approval of AGE. 12 SS Pump shaft. 13 CI Impeller complete with impeller key. 14 Shaft sleeve bronze with locking screw & lock nut. 15 Wearing ring (DE &NDE) CI 16 Set ofO ring 17 CI gland cap with eye bolt complete. 18 GM gland sleeve bush. 19 M&L for disconnecting suction/delivery lines and coupling, taking down from foundation base frame, opening including dismantling of centrifugal pump set of capacity 25 HP and replacement of worn out spare part and re-assembling and installing, commissioning & testing in same location complete all as specified & as directed.Note : (i) The spare parts required to be replaced shall be measured and paid for separately as Supply only under the relevant item of this Schedule.(ii) Unit rate shall be deemed to include for all minor spares/extras. 20 Supply only the following spare parts for centrifugal pump set of capacity 25 HP against serial item No. 5.00 here-in-before as per existing make, complete all as specified & as directed.Note : All spare parts shall be fixed in the pumps only after prior inspection & approval of AGE. 21 SS Pump shaft. 22 CI Impeller complete with impeller key. 23 Shaft sleeve bronze with locking screw & lock nut. 24 Wearing ring (DE &NDE) CI 25 Set ofO ring 26 CI gland cap with eye bolt complete. 27 GM gland sleeve bush. 28 M&L for disconnecting suction/delivery lines and coupling, taking down from foundation base frame, opening including dismantling of centrifugal pump set of capacity 40 HP and replacement of worn out spare part and re-assembling and installing, commissioning & testing in same location complete all as specified & as directed.Note : (i) The spare parts required to be replaced shall be measured and paid for separately as Supply only under the relevant item of this Schedule.(ii) Unit rate shall be deemed to include for all minor spares/extras. 29 Supply only the following spare parts for centrifugal pump set of capacity 40 HP against serial item No. 7.00 here-in-before as per existing make, complete all as specified & as directed.Note : All spare parts shall be fixed in the pumps only after prior inspection & approval of AGE. 30 SS Pump shaft. 31 CI Impeller complete with impeller key. 32 Shaft sleeve bronze with locking screw & lock nut. 33 Wearing ring (DE &NDE) CI 34 Set ofO ring 35 CI gland cap with eye bolt complete. 36 GM gland sleeve bush. 37 M&L for disconnecting suction/delivery lines and coupling, taking down from foundation base frame, opening including dismantling of centrifugal pump set of capacity 50 HP and replacement of worn out spare part and re-assembling and installing, commissioning & testing in same location complete all as specified & as directed.Note : (i) The spare parts required to be replaced shall be measured and paid for separately as Supply only under the relevant item of this Schedule.(ii) Unit rate shall be deemed to include for all minor spares/extras. 38 Supply only the following spare parts for centrifugal pump set of capacity 50 HP against serial item No. 9.00 here-in-before as per existing make, complete all as specified & as directed.Note : All spare parts shall be fixed in the pumps only after prior inspection & approval of AGE. 39 SS Pump shaft. 40 CI Impeller complete with impeller key. 41 Shaft sleeve bronze with locking screw & lock nut. 42 Wearing ring (DE &NDE) CI 43 Set ofO ring 44 CI gland cap with eye bolt complete. 45 GM gland sleeve bush. 46 M&L for disconnecting suction/delivery lines and coupling, taking down from foundation base frame, opening including dismantling of centrifugal pump set of capacity 2 HP and replacement of worn out spare part and re-assembling and installing, commissioning & testing in same location complete all as specified & as directed.Note : (i) The spare parts required to be replaced shall be measured and paid for separately as Supply only under the relevant item of this Schedule.(ii) Unit rate shall be deemed to include for all minor spares/extras. 47 Supply only the following spare parts for centrifugal pump set of capacity 2 HP against serial item No. 11.00 here-in-before as per existing make, complete all as specified & as directed.Note : All spare parts shall be fixed in the pumps only after prior inspection & approval of AGE. 48 SS Pump shaft. 49 CI Impeller complete with impeller key. 50 Shaft sleeve bronze with locking screw & lock nut. 51 Wearing ring (DE &NDE) CI 52 Set ofO ring 53 CI gland cap with eye bolt complete. 54 GM gland sleeve bush. 55 M&L for disconnecting suction/delivery lines and coupling, taking down from foundation base frame, opening including dismantling of centrifugal pump set of capacity 5 HP and replacement of worn out spare part and re-assembling and installing, commissioning & testing in same location complete all as specified & as directed.Note : (i) The spare parts required to be replaced shall be measured and paid for separately as Supply only under the relevant item of this Schedule.(ii) Unit rate shall be deemed to include for all minor spares/extras. 56 Supply only the following spare parts for centrifugal pump set of capacity 5 HP against serial item No. 13.00 here-in-before as per existing make, complete all as specified & as directed.Note : All spare parts shall be fixed in the pumps only after prior inspection & approval of AGE. 57 SS Pump shaft. 58 CI Impeller complete with impeller key. 59 Shaft sleeve bronze with locking screw & lock nut. 60 Wearing ring (DE &NDE) CI 61 Set ofO ring 62 CI gland cap with eye bolt complete. 63 GM gland sleeve bush. 64 M&L for taking down defective induction motor of following capacity from the foundation, disconnecting the electric connections, coupling pully and transporting to work shop for repair, cutting down and removing existing burnt out copper winding, cleaning of slots and rewinding with solid copper conductor (winding wire) complete including varnishing, drying, ovening, overhauling, greasing and fixing in the same position, making necessary electric connection and testing of induction motor complete all as specified and as directed. Make of winding wire: CHETAK/ DEVIDAYAL/ FINOLEX/ ASIAN/EMGEE 65 2 HP capacity, 3 phase, 415 Volt, 50Hz 66 5 HP capacity, 3 phase, 415 Volt, 50Hz 67 10 HP capacity, 3 phase, 415 Volt, 50Hz 68 15 HP capacity, 3 phase, 415 Volt, 50Hz 69 20 HP capacity, 3 phase, 415 Volt, 50Hz 70 25 HP capacity, 3 phase, 415 Volt, 50Hz 71 40 HP capacity, 3 phase, 415 Volt, 50Hz 72 50 HP capacity, 3 phase, 415 Volt, 50Hz 73 S&F 15mm bore Gun metal gate valve (ISI marked) with iron wheel head, screwed both ends for iron pipe, including dismantling & taking out old unserviceable gate valve of 15 mm bore, complete, all as specified & directed. 74 S&F 20mm bore Gun metal gate valve (ISI marked) with iron wheel head, screwed both ends for iron pipe, including dismantling & taking out old unserviceable gate valve of 20mm bore, complete, all as specified & directed. 75 S&F 25mm bore Gun metal gate valve (ISI marked) with iron wheel head, screwed both ends for iron pipe, including dismantling & taking out old unserviceable gate valve of 25mm bore, complete, all as specified & directed. 76 S&F 50mm bore Gun metal gate valve (ISI marked) with iron wheel head, screwed both ends for iron pipe, including dismantling & taking out old unserviceable gate valve of 50mm bore, complete, all as specified & directed. 77 S&F Power Contactor 18 Amp, 3 Pole, 415 Volt, 50 Hz, type MNX-18, conforming IS/IEC 60947-4-1 complete with all accessories including disconnecting & taking down old existing unserviceable contactor complete all as specified and directed. 78 S&F Power Contactor 25 Amp, 3 Pole, 415 Volt, 50 Hz, type MNX-25, conforming IS/IEC 60947-4-1 complete with all accessories including disconnecting & taking down old existing unserviceable contactor complete all as specified and directed. 79 S&F Power Contactor 32 Amp, 3 Pole, 415 Volt, 50 Hz, type MNX-32, conforming IS/IEC 60947-4-1 complete with all accessories including disconnecting & taking down old existing unserviceable contactor complete all as specified and directed. 80 Supply and fixing overload relay range 20-33 Amps direct mounting on MNX power contactor complete including taking down old unserviceable relay complete all as specified & directed. 81 Supply and fixing overload relay range 24-40 Amps direct mounting on MNX power contactor complete including taking down old unserviceable relay complete all as specified & directed. 82 Supply and fixing overload relay range 36-60 Amps direct mounting on MNX power contactor complete including taking down old unserviceable relay complete all as specified & directed. 83 S&F electronic type Single Phase Preventer in existing panel boards (max 600 Volt & min 380 Volt) three phase 415 Volts variation voltage 4% triping time 2-5 second maximum including disconnecting & taking down old unserviceable Single Phasing preventer, complete all as specified & directed. 84 Supply and fixing in replacement of electronic star delta timer ranging from 3 sec to 120 sec, 24-240 VAC/DC type with 1 NO (Star) + 1 NO (Delta) contact arrangement complete all as specified & directed. 85 Supply and fixing in replacement of front mounting Add on auxilary contact block type MNX contactor with 2 NO + 2 NO contact arrangement complete all as specified & directed. 86 S&F Power Contactor 3 Pole, LC1D 09 type, 220 Volt, 50 Hz, complete with all accessories including disconnecting & taking down old existing unserviceable contactor complete all as specified and directed.Make : Schneider Cat Part NO. LC1D 09 or equivalent in L&T/HPL/Havells 87 S&F Power Contactor 3 Pole, LC1D 12 type, 220 Volt, 50 Hz, complete with all accessories including disconnecting & taking down old existing unserviceable contactor complete all as specified and directed.Make : Schneider Cat Part NO. LC1D 12 or equivalent in L&T/HPL/Havells 88 S&F Power Contactor 3 Pole, LC1D 18 type, 220 Volt, 50 Hz, complete with all accessories including disconnecting & taking down old existing unserviceable contactor complete all as specified and directed.Make : Schneider Cat Part NO. LC1D 18 or equivalent in L&T/HPL/Havells 89 S&F Power Contactor 3 Pole, LC1D 80 type, 220 Volt, 50 Hz, complete with all accessories including disconnecting & taking down old existing unserviceable contactor complete all as specified and directed.Make : Schneider Cat Part NO. LC1D 80 or equivalent in L&T/HPL/Havells 90 Supply & fixing cast iron body sluice valve heavy duty class ‘PN-1.6’ of 80mm bore, ISI marked with IS 14846, both flanged ends and drilled, high tensile stainless steel spindle, CI gate with brass ring, non rising type, cast iron wheel handle, cast iron cap, with 3mm thick neoprene rubber gasket joint and nuts, bolts (high tensile), washers etc, and testing, including dismantling & taking out old unserviceable sluice valve of 80 mm bore, complete all as specified & directed. 91 Supply & fixing cast iron body sluice valve heavy duty class ‘PN-1.6’ of 100mm bore, ISI marked with IS 14846, both flanged ends and drilled, high tensile stainless steel spindle, CI gate with brass ring, non rising type, cast iron wheel handle, cast iron cap, with 3mm thick neoprene rubber gasket joint and nuts, bolts (high tensile), washers etc, and testing, including dismantling & taking out old unserviceable sluice valve of 100mm bore, complete all as specified & directed. 92 Supply & fixing cast iron body sluice valve heavy duty class ‘PN-1.6’ of 150mm bore, ISI marked with IS 14846, both flanged ends and drilled, high tensile stainless steel spindle, CI gate with brass ring, non rising type, cast iron wheel handle, cast iron cap, with 3mm thick neoprene rubber gasket joint and nuts, bolts (high tensile), washers etc, and testing, including dismantling & taking out old unserviceable sluice valve of 150mm bore, complete all as specified & directed. 93 S&F in replacement of mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, bolts and washers of any sizes complete all as specified & as directed. 94 M&L for galvanized steel water tubing medium grade of 15mm bore (ISI marked) with & including all fittings and fixed complete to walls and ceiling or laid in floors, including taking up or down old unserviceable steel water tubing of any type and connections of 15mm bore, complete all as specified and directed. 95 M&L for galvanized steel water tubing medium grade of 20mm bore (ISI marked) with & including all fittings and fixed complete to walls and ceiling or laid in floors, including taking up or down old unserviceable steel water tubing of any type and connections of 20mm bore, complete all as specified and directed. 96 M&L for galvanized steel water tubing medium grade of 25mm bore (ISI marked) with & including all fittings and fixed complete to walls and ceiling or laid in floors, including taking up or down old unserviceable steel water tubing of any type and connections of 25mm bore, complete all as specified and directed. 97 M&L for galvanized steel water tubing medium grade of 40mm bore (ISI marked) with & including all fittings and laid in trenches, including taking up or down old unserviceable steel water tubing of any type and connections of 40mm bore, complete all as specified and directed.Note :- Excavation & earthwork shall be measured & paid for separately. 98 M&L for galvanized steel water tubing medium grade of 50mm bore (ISI marked) with & including all fittings and laid in trenches, including taking up or down old unserviceable steel water tubing of any type and connections of 50mm bore, complete all as specified and directed.Note :- Excavation & earthwork shall be measured & paid for separately. 99 M&L for galvanized steel water tubing medium grade of 80mm bore (ISI marked) with & including all fittings and laid in trenches, including taking up or down old unserviceable steel water tubing of any type and connections of 80mm bore, complete all as specified and directed.Note :- Excavation & earthwork shall be measured & paid for separately. 100 M&L for galvanized steel water tubing medium grade of 100mm bore (ISI marked) with & including all fittings and laid in trenches, including taking up or down old unserviceable steel water tubing of any type and connections of 100mm bore, complete all as specified and directed.Note :- Excavation & earthwork shall be measured & paid for separately. 101 M&L for Earthing to Transformer / GOD switch / equipments / panels etc with & including galvanised mild steel earth plate electrode of size 60cm x 60cm x 6mm thick buried vertically in ground (earth pit not less than2.25 m below normal ground level) with top edge of the earth plate at a depth not less than 1.5 m below ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15cm on all sides, connected to & including galvanized mild steel strip 32x6 mm as earth lead, including nuts, bolts, check nuts & washers of galvanized iron or steel and riveted/ welded to earth plate at one end and other end of strip connected to transformer / GOD / Panel / equipment body / test point with two Nos nuts bolts or welding with steel structure, GI earth strip encased in and including 40mm bore GI light grade pipe with all fittings from upper edges of earth plate upto 7.5 metre above ground level fixed with and including 25x3mm flat iron clamps, bolts, nuts and washer and also including providing watering pipe 20mm bore GI pipe medium grade from earth pit to top of electrode and including funnel, wire mesh, copper lugs etc complete with earth pit in PCC 1:3:6 type C1 using 20mm graded crushed stone aggregate and 40mm thick RCC (1:2:4 type B1) cover complete all as specified and shown in electrical plate No 3 of SSR Part-I including necessary excavation and earthwork in any type of soil, returning, filling in approved soil and disposal of surplus soil to a distance not exc 50mincluding dismantling & taking out old existing unserviceable earthing complete all as specified and as directed.Note : PCC chamber shall be constructed at least 1.5 mtr away from the earth electrode and pipe for watering shall be provided in slanting manner. 102 Supply and fixing non return valve (NRV) of size 80mm bore, cast iron body, as per IS 5312 (ISI marked), heavy duty, class ‘PN-1.6’, gun metal seat, both ends flanged and drilled, including nuts, bolts, washer and neoprene rubber gasket joint including dismantling & taking out old unserviceable non return valve of 80mm bore complete all as specified and as directed. 103 Supply and fixing non return valve (NRV) of size 100mm bore, cast iron body, as per IS 5312 (ISI marked), heavy duty, class ‘PN-1.6’, gun metal seat, both ends flanged and drilled, including nuts, bolts, washer and neoprene rubber gasket joint including dismantling & taking out old unserviceable non return valve of 100mm bore complete all as specified and as directed. 104 Supply and fixing non return valve (NRV) of size 150mm bore, cast iron body, as per IS 5312 (ISI marked), heavy duty, class ‘PN-1.6’, gun metal seat, both ends flanged and drilled, including nuts, bolts, washer and neoprene rubber gasket joint including dismantling & taking out old unserviceable non return valve of 150mm bore complete all as specified and as directed. 105 Supply & fixing Ammeter Digital type, 0 to 100 Amp range, flush mounting type, three Phase, 415 Volt, AC with CTs of ratio 100/5 Amp in all three phases including dismantling and taking down old unserviceable complete all as specified and as directed. 106 Supply & fixing Voltmeter Digital type, 0 to 600 Volt range, flush mounting type, three phase, 415 Volt, AC including dismantling and taking down old unserviceable complete all as specified and as directed. 107 Supply and fixing in replacement voltage selector switch 415 volts, 50 Hz rotary type consisting of O, RY, YB and BR complete all as specified as directed. 108 Supply and fixing in replacement ammeter selector switch rotary type consisting of O, R, Y and B complete all as specified as directed. 109 S&F in replacement of indicator lamp LED type, 230 Volts, AC (Different colours for indicating R, Y, B phases) with holder complete all as specified and directed. 110 S&F MCCB 4 Pole 63 Amps, adjustable thermal magnetic having, breaking capacity 16 KA, 415 Volt and connections, including disconnecting & taking down old unserviceable MCCB, complete all as specified and directed. Make : L&T/C&S/Havells/HPL. 111 S&F MCCB 4 Pole 100 Amps, adjustable thermal magnetic having, breaking capacity 25 KA, 415 Volt and connections, including disconnecting & taking down old unserviceable MCCB, complete all as specified and directed. Make : L&T/C&S/Havells/HPL 112 S&F MCCB 4 Pole 200 Amps, adjustable thermal magnetic having, breaking capacity 25 KA, 415 Volt and connections, including disconnecting & taking down old unserviceable MCCB, complete all as specified and directed. Make : L&T/C&S/Havells/HPL 113 S&F MCCB 4 Pole 250 Amps, adjustable thermal magnetic having, breaking capacity 25 KA, 415 Volt and connections, including disconnecting & taking down old unserviceable MCCB, complete all as specified and directed. Make : L&T/C&S/Havells/HPL 114 Collecting raw water and treated water sample from UG Sump of Main Pump House respectively and testing of both for chemical and bacteriological analysis from Govt/ NABL accredited laboratory monthly or whenever required or ordered by Engineer - in-Charge. 115 Collecting raw water and treated water sample from borewell and RO plant respectively and testing of both for chemical and bacteriological analysis from Govt/ NABL accredited laboratory monthly or whenever required or ordered by Engineer- in-Charge. 116 M&L for preparation of old painted exposed surface of centrifugal pump set of capacity 5 HP, with suction line from UG sump to pump set and delivery pipe line and outlet pipe line from pump set to wall/pit as observed inside pump house, operating valves (Non return valves/ sluice valves/ Gate valves) any size by removing dust, dirt, oil, grease etc and painting with two coats of synthetic enamel paint of superior quality as per existing colour or as appropriate colour using spray gun machine and writing SM/MES No to pump sets with white paint complete all as specified and directed.Make : Asian paint/Burger/Nerolac 117 M&L for preparation of old painted exposed surface of centrifugal pump set of capacity 10 HP, with suction line from UG sump to pump set and delivery pipe line and outlet pipe line from pump set to wall/pit as observed inside pump house, operating valves (Non return valves/ sluice valves/ Gate valves) any size by removing dust, dirt, oil, grease etc and painting with two coats of synthetic enamel paint of superior quality as per existing colour or as appropriate colour using spray gun machine and writing SM/MES No to pump sets with white paint complete all as specified and directed.Make : Asian paint/Burger/Nerolac 118 M&L for preparation of old painted exposed surface of centrifugal pump set of capacity 12.5 HP, with suction line from UG sump to pump set and delivery pipe line and outlet pipe line from pump set to wall/pit as observed inside pump house, operating valves (Non return valves/ sluice valves/ Gate valves) any size by removing dust, dirt, oil, grease etc and painting with two coats of synthetic enamel paint of superior quality as per existing colour or as appropriate colour using spray gun machine and writing SM/MES No to pump sets with white paint complete all as specified and directed.Make : Asian paint/Burger/Nerolac 119 M&L for preparation of old painted exposed surface of centrifugal pump set of capacity 20 HP, with suction line from UG sump to pump set and delivery pipe line and outlet pipe line from pump set to wall/pit as observed inside pump house, operating valves (Non return valves/ sluice valves/ Gate valves) any size by removing dust, dirt, oil, grease etc and painting with two coats of synthetic enamel paint of superior quality as per existing colour or as appropriate colour using spray gun machine and writing SM/MES No to pump sets with white paint complete all as specified and directed.Make : Asian paint/Burger/Nerolac 120 M&L for preparation of old painted exposed surface of centrifugal pump set of capacity 25 HP, with suction line from UG sump to pump set and delivery pipe line and outlet pipe line from pump set to wall/pit as observed inside pump house, operating valves (Non return valves/ sluice valves/ Gate valves) any size by removing dust, dirt, oil, grease etc and painting with two coats of synthetic enamel paint of superior quality as per existing colour or as appropriate colour using spray gun machine and writing SM/MES No to pump sets with white paint complete all as specified and directed.Make : Asian paint/Burger/Nerolac 121 M&L for preparation of old painted exposed surface of centrifugal pump set of capacity 40 HP, with suction line from UG sump to pump set and delivery pipe line and outlet pipe line from pump set to wall/pit as observed inside pump house, operating valves (Non return valves/ sluice valves/ Gate valves) any size by removing dust, dirt, oil, grease etc and painting with two coats of synthetic enamel paint of superior quality as per existing colour or as appropriate colour using spray gun machine and writing SM/MES No to pump sets with white paint complete all as specified and directed.Make : Asian paint/Burger/Nerolac 122 M&L for preparation of old painted exposed surface of centrifugal pump set of capacity 50 HP, with suction line from UG sump to pump set and delivery pipe line and outlet pipe line from pump set to wall/pit as observed inside pump house, operating valves (Non return valves/ sluice valves/ Gate valves) any size by removing dust, dirt, oil, grease etc and painting with two coats of synthetic enamel paint of superior quality as per existing colour or as appropriate colour using spray gun machine and writing SM/MES No to pump sets with white paint complete all as specified and directed.Make : Asian paint/Burger/Nerolac 123 Supply and fixing in replacement hard teak wood display board double door type made of size 1200 mm x 900 mm with frame duly painted with suitable double coat paint complete with inside rexine for fixing of papers with movable glass fittings & locking arrangement complete all as specified and directed. 124 M&L for disconnecting all electric/water supply connections from the electric panel/water pipe line, lifting of submersible pump set of capacity 15 HP from the bore well for repairs of submersible pumpset with the help of electric hoist / manually chain pully block including opening of flanged joints of column pipe and stacking it in safe custody for reuse as required complete all as specified and directed. 125 M&L for Lowering of vertical type submersible pump set of capacity 15 HP into the bore after repair upto 190 metre below ground level with the help of chain pully block including new rubber gasket between flange joints with nuts, bolts, washers of column pipe (3 metre length) making electrical connections, testing and commissioning of pump set for satisfactory operation complete all as specified and directed. 126 M&L for dismantling of submersible pumpset capacity 15 HP including repair and maint, greasing, oiling and assembling, testing and commissioning complete all as specified and directed. Note : (i)Spare parts for submersible pump 15 HP capacity as required are measured and paid seperately. (ii) Spare parts required for replacement of existing worn out parts shall be measured and paid separately under item No 69.01 toto 69.07Labour for replacement/fixing of the supply only and minor parts such as Nuts and bolts items shallbe deemed to be included in the unit rate quoted against this item. 127 SS Rotor Sleeve suitable for submersible pump set of 15 HP. 128 GM Housing Bush suitable for submersible pump set of 15 HP. 129 Thrust bearing suitable for submersible pump set of 15 HP. 130 Water seal suitable for submersible pump set of 15 HP. 131 GM Impeller suitable for submersible pump set of 15 HP. 132 Shaft sleeve suitable for submersible pump set of 15 HP. 133 Neck Ring suitable for submersible pump set of 15 HP. 134 Disconnecting & taking down the existing unserviceable water tank and Supply and fixing 1000 Litre capacity Rotational moulded polyethylene water storage tanks double layered (cylindrical vertical with closed top) ISI marked, hoisted & fixed in position & making necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc. complete as specified in SSR Part-I and as directed. 135 M&L for name board with green acrylic radium sheet for pump house/ installation with suitable sheet of size 1.20 mtr x 0.90 mtr with suitable stainless steel frame workwith pedestal of dimension 2.5 mtr x 1.20 mtr, 40 mm dia stainless steel rod including suitable size & shape of letters printed on both side with necessary earth work, PCC foundation etc including painting/framing work complete all as specified and directed.Note:- (i) Size and shape of letters and other things should be as per sample kept in AGE office sample room.(ii) The cost of above item deemed to be inclusive in qouted rates of this item. 136 Supply & installation of Smart Integrated All in one Solar Street Light with Built in Mono Crystalline Panel, Lithium Ferro Phospate (LiFeP0 4) Battery, MPPT Charge Controller and PIR Sensor with Colour Temperature 6000-6500 K having capacity 20 Watt ,IP 65, 120 lumens/watt, min 12.8 Volt/ 21 AH lithium ferrous phopshate battery, 40 W (monocrystalline) 18 Volt Solar panel, LED life 50000 hours including bracket made out of suitable size of GI tubing medium grade and fixed with clamps nuts and bolts, washer, suitable length MS tubular pole medium grade with painting as per manufacturer recommendation, testing & commissioning complete including taking down old unserviceable lighting system complete all as specified and directed.Make : Bajaj Cat Part No. BSZSL 20 W LED, Surya, Orient, Crompton, PhilipsNote: (i) Contractor has to furnish a replacement warranty of 05 years for solar street light fittings complete including lamps from the date of completion of contract. The product will be replaced free of cost in the following case :-(a) Manufacturing defects.(b) Failure due to mechanical and electrical impact.(c) Drop in lumen (or lux at 1 m) below 90% of claimed values of lumen (or lux at 1 m) of the LED /Luminaries. 137 M&L for PCC 1:4:8 type D2 using 40 mm graded crushed stone aggregate as in foundations, filling and mass concrete complete all as specified and as directed. 138 M&L for PCC 1:3:6 type C2 using 40 mm graded crushed stone aggregate as in foundations of poles/struts etc. filling and mass concrete complete all as specified and as directed. 139 M&L for PCC 1:2:4 type B1 using 20mm graded crushed stone aggregate as in coping of poles/ struts including necessary formwork as required complete all as specified and as directed. 140 Supply, installation, testing and commissioning factory made and tested (CPRI type test certified) LT feeder pillar box (KIOSK), indoor type (cubical type), floor mounted, suitable for 415 volts 3 phase & neutral, 4 wire, 50 Hz AC supply system having bus bar chamber with insulated aluminium bus bars suitable capacity in colour code RYB with 3 phase & neutral installed on porcelain insulators with bus bar chamber shall be provided with inspection covers, each MCCB/cubical switch independent opening. The panel shall be dust & vermin proof, protection class IP-65 and made out of CRCA sheet of 3mm thick, powder coated finish on outside & inside surfaces (approved shade), double door (front & rear), in two shalves with provision of rubber beading and front opening type with aprons for cable entry, with double door shutter & locking arrangement {including provn of 65mm Godrej (Freedom) lock with 2 keys}, dange notice board in front and rear sidesand MS angle iron frame work (made out of 40mmx40mmx5mm thick), frame legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, legs grouted in PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) including internal wiringwith PVC insulated, solid copper conductor, FRLS cables, IS-694 marked of adequate size but not less than 6 sqmm with proper ferrule & cable gland inlcuding taking down old unserviceable LT panel complete and also comprising of the following:- 141 (Description of serial item No. 76.00 Contd….)(a) MCCB, 4 Pole, 250 Amps, rupturing capacity 25 KA, Ics=100% Icu, 415 Volt grade, AC, 50 Hz, adjustable Thermal - Magnetic setting - 01 No. (Incoming).(b) Bus bar electrolytic grade aluminium and supported on Non-hygroscopic, non carbonising, corrosion resistance SMC insulators 400 Amp, 4 pole, not less than 30cm long mounted on insulators for incomming supply - 01 No. (Incoing).(c) MCCB, 4 Pole, 100 Amps, rupturing capacity 25 KA, Ics=100% Icu, 415 Volt grade, AC, 50 Hz, adjustable Thermal - Magnetic setting - 03 Nos (Outgoing).(d) MCCB, 4 Pole, 63 Amps, rupturing capacity 25 KA, Ics=100% Icu, 415 Volt grade, AC, 50 Hz, adjustable Thermal - Magnetic setting - 01 Nos (Outgoing).(e)MCB 63 Amp rating, TPN, rupturing capacity 10 kA, ‘C’ Series - 03 No (Outgoing)(f) MCB 32 Amp rating, DP, rupturing capacity 10 kA, ‘C’ Series - 03 No (Outgoing)(g) MCB 32 Amp rating, SP, rupturing capacity 10 kA, ‘C’ Series - 04 No (Outgoing)(h) Digital Volt meter, Digital Amp meter with built in selector switch including necessary CTs (set of three) - 1 Set.(j)Neon Indicator lamps Set RYB, “LED” type (set of three) - 04 Set(k) Star-delta starter suitable for 10 HP, 20 HP and 40 HP pump set alongwith suitable size of contactor (Main, star and delta) alongwith add on block if desired, overload relay, Single Phasing preventor and timer (suitable for 10 HP, 20 HP and 40 HP respectivily) - 03 No. (Outgoing)(l) On Load Changeover switch 200 Amps, 4 Pole, 415 volt, 50 Hz, sheet steel enclosure with front handle - 01 (Outgoing) 142 Notes for serial item No. 76.00 Contd :- (i)Vertical height of legs of LT panel base frame shall be not less than 45cm from top of nearest road level / PCC floor finish. Legs shall be grouted in PCC (1:2:4) type B1 (using 20mm graded crushed stone aggregate). (ii) The contractor shall produce and get the detailed drawings of LT Panel approved from AGE before fabrication and placing the order to the approved manufacturer. (iii) The quoted rate shall deemed to include supply & provision of built in flush type locks (with 02 keys) of superior quality as directed by Engineer in Charge. (iv) MS frame work shall be painted with two coats of synthetic enamel paint of approved tint over a coat of red oxide primer. (v) Cost of MS frame work, painting, platform, MCCB spreaders, cable glands, locking arrangement with lock and key and any minor addition/alteration where required at site (the decision of AGE will be final and binding regarding extent to which the change can be considered as minor addition/alteration) shall be deemed to be included in the quoted rates.(vi) Wiring complete with multistranded copper conductor PVC insulated unsheathed cable of suitable size in rigid steel conduit stove enameled complete from starter to pump terminal box.(vii) Rates quoted is deemed to be inclusive of PCC foundation/pedestrian and connected earth work. 143 M&L for disconnecting suction/delivery lines and coupling, taking down from foundation base frame, opening including dismantling ofMain fire pump set split casing type of capacity 100 HP and replacement of worn out spare parts and re-assembling, to be installed in same location,commissioning & testing complete all as directed.Note : (i) The spare parts required to be replaced shall be measured and paid for separately as Supply only under the relevant item here in after.(ii) Unit rate shall be deemed to include for all minorspares/extras. 144 Supply only the following spare parts of Main fire pump set split casing type of capacity 100 HP against serial item No. 77.00 here-in-before as per existing make complete all as specified and directed. 145 Bronze Impeller complete with impeller key. 146 Shaft sleeve bronze with locking screw & lock nut. 147 Wearing ring (DE &NDE) Bronze 148 Set ofO ring 149 CI gland cap with eye bolt complete. 150 GM gland sleeve bush. 151 De-watering the existing RCC semi underground water reservoir of 450000 Gallon capacity, cleaning all internal surfaces of roof, walls, & floors, all accumulated silt, mud, etc including grass, vegetation etc or any other deposited material inside the water reservoir including lifting the materials from the reservoir and getting out from the reservoir without any damage to reservoir including removing sludge, silt, mud, etc to a distance exc 50m but not exc. 250m from the outer edge of the reservoir and depositing where directed outside the reservoir, scrubbing with water using jute/bushes and washing the surfaces with mixture of bleaching powder & fresh water, finally washing the surfaces with fresh water and treating all internal surfaces with one coat of white wash complete and writing capacity of reservoir, date of cleaning & due date of next cleaning in thick synthetic enamel paint on outer surface of reservoir in block capital letters of height 25cm complete all as directed. 152 De-watering the existing RCC semi underground water reservoir of 525000 Gallon capacity, cleaning all internal surfaces of roof, walls, & floors, all accumulated silt, mud, etc including grass, vegetation etc or any other deposited material inside the water reservoir including lifting the materials from the reservoir and getting out from the reservoir without any damage to reservoir including removing sludge, silt, mud, etc to a distance exc 50m but not exc. 250m from the outer edge of the reservoir and depositing where directed outside the reservoir, scrubbing with water using jute/bushes and washing the surfaces with mixture of bleaching powder & fresh water, finally washing the surfaces with fresh water and treating all internal surfaces with one coat of white wash complete and writing capacity of reservoir, date of cleaning & due date of next cleaning in thick synthetic enamel paint on outer surface of reservoir in block capital letters of height 25cm complete all as directed. 153 Note for serial item No. 79.00 to 80.00 Contd... :- (i) The sludge may be including water slush type of solids and the contractor shall not have any claim whatsoever on this account. (ii) The mixture of bleaching powder & water for cleaning shall be prepared by mixing 250 gm of bleaching powder in 10 litres of fresh water. (iii) All inlets/outlets/over flow/wash out connections shall be cleaned. Any leakage in joints shall be made good as directed and quoted rate also includes this aspect.(iv) The existing water, water used for cleaning etc shall be bailed out at the nearest open drain available.(v) Any damage occurred to the assets during cleaning etc shall be made good by the contractor at his own cost. (vi) All protective & safety measures for workmen against Honey Bee, insects, creatures, gases, height etc shall be responsibility of the contractor. The quoted rate shall be deemed to include for this provision. (vii) The contractor must carried out all the process in such a way that the complete inside cleaning process as mentioned above must be finished instipulated time decided by Engineer-in-charge to produce minimum disturbance to regular water supply to connected area. If contractor fails to restore the water supply within stipulated time, as decided by Engineer-in-charge, the penal recovery of Rs - 2000.00 per day will be recovered from contractors dues. (viii) All the equipment/material required for cleaning of tank / sump such as sludge pump/Raw water pump/DG Set with connecting cable will be brought by the contractor and no extra cost will be paid in this effect.(ix) Removal of Algae, Calcinations etc from the walls with rotary cleaner/scrubber machine/wire brushes etc. (x) Tank to be sterilized and disinfected with the help of UV lamp for min 01 hr to make bacteria free. (xi) Walls and ceiling to be sterilized with Anti Bacterial Solution (using 15 % by Volume of H2O2/silver ion) for making it bacteria free.(xii) Complete removal of remaining sludge, accumulated mud, silt, sand with the help of vacuum cleaners. 154 Supply and fixing in replacement of PVC insulated 3 core, 4 sqmm copper multistranded PVC sheathed submersible flexible cable ISI marked and confirming to IS:694 and connecting to submersible pump and to LT Panel complete all as specified and directed. 155 Supply and fixing in replacement of PVC insulated 3 core, 6 sqmm copper multistranded PVC sheathed flexible cable ISI marked and confirming to IS:694 and connecting to pump set and to LT Panel complete all as specified and directed. 156 Supply and fixing in replacement of PVC insulated 3 core, 10 sqmm copper multistranded PVC sheathed flexible cable ISI marked and confirming to IS:694 and connecting to pump set and to LT Panel complete all as specified and directed. 157 S&F in replacement of MS pipe 80mm bore heavy duty Class C (ISI Marked) for pumping set suction line/ discharge water line includingwith necessary fittings sch as bend, elbow, tee, socket including cutting, threading, welding etc and replacement of wornout, MS nut, bolts, washers & sockets flange etc including complete painting with two coat of bituminous paint over a coat of zinc chrome primer complete all as specified and directed. 158 S&F in replacement of MS pipe 100mm bore heavy duty Class C (ISI Marked) for pumping set suction line/ discharge water line includingwith necessary fittings sch as bend, elbow, tee, socket including cutting, threading, welding etc and replacement of wornout, MS nut, bolts, washers & sockets flange etc including complete painting with two coat of bituminous paint over a coat of zinc chrome primer complete all as specified and directed. 159 M&L for taking out existing flange joint of 80mm dia & make new flange joint complete with rubber or fibre board gaskets, tightening by existing nut bolts complete with welding as desired testing for flange joints etc complete all as specified & as directed. 160 M&L for taking out existing flange joint of 100mm dia & make new flange joint complete with rubber or fibre board gaskets, tightening by existing nut bolts complete with welding as desired testing for flange joints etc complete all as specified & as directed. 161 Excavating in trenches, not exc 1.5 metre wide and not exc 1.5 metre in depth, for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. laying cables, pipes, etc. not exc 10 Sqm on plan & not exc 1.5m in depth and getting out in soft/loose soil complete all as specified and as directed. 162 Returning, filling in, including spreading, leveling watering and well ramming in layers not exc 25 cm thick in soft/loose soil complete all as specified and as directed. 163 Removing excavated soil/material to a distance not exc 50 metre and depositing where directed at a level not exc 1.50 metre above the starting point complete all as specified and as directed. 164 Supply and fixing in replacement fully automatic star delta starter (FASD) suitable for pump set upto 15 HP complete all as specified and directed.Make : Havells/ L&T/ Shakti/ Siemens 165 Supply and mixing (day to day operation) NSF certified food grade RO antiscalant for effective in controlling deposition of organic/ inorganic scalants and such as calcium carbonate, calcium sulphate, Barium sulphate, strontium sulphate, calcium flouride, iron, colloidal material, silica and other organic contaminants. Antiscalant should be effective over a wide pH range. complete all as specified and directed. 166 Supply and fixing in replacement superior quality micro filter jambo of existing size 6 inch/ 24 inch as per existing filter complete all as per speicified and directed. 167 Supply and fixing in replacement stainless steel pipe 50mm dia (SH 40S, grade TP 316 L) including fittings such union, elbow, tee, sockets etc low corrosive, high resistant to rusting and corrosion, can withstand high pressure including cutting, threading, welding and testing satisfactorily as per existing complete all as per speicified and directed. 168 Supply and fixing in replacement stainless steel pipe 25mm dia (SH 40S, grade TP 316 L) including fittings such union, elbow, tee, sockets etc low corrosive, high resistant to rusting and corrosion, can withstand high pressure including cutting, threading, welding and testing satisfactorily as per existing complete all as per speicified and directed. 169 Supply and fixing in replacement rotameter/flow meter suitable for RO Plant of capacity 10000 Litre/Hour as existing in RO panel or Raw water line complete all as specified and directed. 170 Cleaning of water tank 50000 ltrs at RO plant, removing sludge / sand / dirt by means of manual / sludge removing pump, cleaning the sumps with bleached water and washing with sodium hydrochloride liquid, drying and applying one coat of lime wash internally and spraying anti bacteria liquid, writing date of cleaning on outer wall of sump with white paint on black base for following capacity of sumps complete all as specified and directed.Note - (i) Sludge / sand / dirt shall be disposed off from the sump at a distance beyond 150m as directed by Engineer-in- Charge.(ii) Cost of all T&P such as ladder etc is deemed to be included in rate quoted. 171 Supply and fixing in replacement CPVC pipe 50mm dia ISI marked including fittings such union, elbow, tee, sockets etc, resistant to corrosion, can withstand high pressure including cutting, jointing and testing satisfactorily as per existing complete all as per speicified and directed. 172 Supply and fixing in replacement anti scaling dosing pump as per existing size and capacity installed at RO Plant complete all as per specified and directed. 173 Supply and fixing in replacement low pressure cut out switch as per existing installed at RO Plant complete all as per specified and directed. 174 Supply and fixing in replacement high pressure cut out switch as per existing installed at RO Plant complete all as per specified and directed. 175 Supply and fixing in replacement Multi port valve as per existing installed at RO Plant complete all as per specified and directed. 176 Supply and fixing pressure guage assembly 0 to 100 Psi or 7 kg/cm2 as per existing installed at RO Plant including taking down old one all as per specified and directed. 177 M&L for replacement single headed fire hydrant valve made out of brass / GM and 63mm bore, all as per IS-5290 type B complete all as directed connected and testing complete all as specified and directed.Make:- Minimex/ Safex/ Newage/ Agni 178 M&L for replacement double headed fire hydrant valve made out of brass / GMand 63mm bore, all as per IS-5290 type B complete all as directed connected and testing complete all as specified and directed. Make:- Minimex/ Safex/ Newage/ Agni 179 S&F in replacement double door hose box suitable for having 02 Nos, 15 to 30 metre long, 63mm bore hose pipes made out of 18 guage MS sheet with 4mm thick glass complete with frame door etc and duly painted of desired colour etc complete all as specified and directed.Note : Hose pipe will be measured and paid separately under this item.Make:- Minimex/ Safex/ Newage/ Agni 180 S&F in replacement of RRL hose Pipe, class ‘A’ conforming to IS 636, 15 metre long, 63mm dia with gun metal male/ female couplings including branch pipe gun metal 63mm and brass nozzle of suitable size complete all as specified and as directed. Make : Newage/ Dunlop/ Cosmos/ Minimex/ Safex/ Agni 181 Supply and fixing in replacement Base board, printed circuit board with micro controller as per existing for diesel engine pump auto panel, suitable for diesel engine pump of capacity 75 KW complete all as specified and directed. 182 Supply and fixing in replacement SMPS (Switch board power supply) type automatic battery charger of capacity 12 Volt, 10 Amp as per existing for diesel engine pump auto panel, suitable for Diesel engine pump of capacity 75 KW complete all as specified and directed. 183 Supply and fixing in replacement 12 VDC type 10 Amp, 250 Volt, 2.5 VA, DIN mounting, screw connectors, mixed contact relay compatible for hard-wired logic automated system to complement the functions of PLCs for diesel engine pump auto panel, suitable for Diesel engine pump of capacity 75 KW complete all as specified and directed. Make : Schnieder RXZE2M114 / L&T/C&S. 184 Supply and fixing in replacement cast steel ball valveASME B16.5 Class-150 (Drilled)with both ends flanged three piece design of size 25mm as per existing including nuts, bolts and washers complete all as specified and directed.Make : Sant/Kirloskar/L&t/Venus 185 Supply and fixing in replacement UPS of capacity 600 VA for Building Management system complete all as specified and directed. 186 Supply and fixing in replacement Y type strainer in suction line of dia 100mm both ends flanged with all fittings and nuts, bolts of desired size as per existing complete all as specified and directed. 187 M&L for replacement of MS fire pipe leakage of 80/100/150 mm pipe under floor in bldg with arc welding including patch up MS piece plate with 5 mm thickness including painting with synthetic enamel paint and necessary earth work, excavation, returning filling and making good the floor complete all as specified and directed. 188 M&L for testing Jockey pump, Main fire pump and Diesel engine driven pump of fire fighting room according to pressure setting of each pump set as desired by authorised OEM complete for both manual and auto operation complete all as specified and directed. 189 De-watering the existing RCC water tank of 325 KL capacity and cleaning all internal surfaces of roof, walls & floor, remove scales, mud & other foreign material, scrubbing with water using jute/ bushes and washing the surface with mixture of bleaching powder & fresh water finally washing the surface with fresh water and treating all internal surfaces with Two coats of white wash complete all as specified and directed. 190 Supply & fixing butterfly valve class ‘PN-1.6’ with SS-304 disc of 150mm bore, ISI marked, both flanged ends and drilled, gear operated having nitrile lining with 3mm thick neoprene rubber gasket joint and nuts, bolts (high tensile), washers etc, and testing, including dismantling & taking out old unserviceable butterfly valve of 150mm bore, complete all as specified & directed. 191 Supply & fixing butterfly valve class ‘PN-1.6’ with SS-304 disc of 200mm bore, ISI marked, both flanged ends and drilled, gear operated having nitrile lining with 3mm thick neoprene rubber gasket joint and nuts, bolts (high tensile), washers etc, and testing, including dismantling & taking out old unserviceable butterfly valve of 200mm bore, complete all as specified & directed. 192 M&L for painting of electrical operated fire pump of horizontal split casing type with TEFC motor class F insulation of capacity 100 HP, 3 Phase, 415 volts, including suction and discharge pipe line and air cushion vessel with drain and safety valves of appx length 2.5 mtr long and 250mm dia MS pipes, foundation frame and painting of all valve controls (all types of valves and pipe lines in fire fighting room) with scrapping the existing paint with wire brush and painting with two coats of synthetic enamelled spray paint of existing colour of superior quality after making good to existing painted surfaces complete all as specified and directed. 193 M&L for painting of Diesel Engine driven pump of split casing type of capacity 75 KW with connected pipe lines, foundation frame and all control valves with scrapping the existing paint with wire brush and painting with two coats of synthetic enamelled spray paint after making good to existing painted surfaces complete all as specified and directed. 194 Material and labour for painting of Jockey pump with TEFC squirrel cage motor class F insulation of cap 20 HP with connected pipelines, foundation frame and all control valves by scrapping the existing paint with wire brush and painting with two coats of synthetic enamelled spray paint after making good to existing painted surfaces complete all as specified and directed. 195 M&L for painting of hose box double door type as existing colour with two coats of synthetic enamel paint by spray painting of asian make and removal of existing paint by hand scrapping preparing the surfaces by sand paper and cleaning the surface and making good damaged surface by denting, welding, grinding all as required for completion of job complete all as specified and directed. 196 M&L for painting of fire hydrant post 80 mm dia with double headed fire hydrant valve as existing colour with two coats of synthetic enamel paint by spray painting of Asian make and removal of existing paint by hand scrapping preparing the surfaces by sand paper and cleaning the surface and making good damaged surface by denting,welding,grinding all as required for completion of job complete all as specified and directed. 197 Disconnecting and dismantling the electric motor of defective Jockey pump set of capacity 20 HP, 03 Phase, 415 volts from the system, shifting to civil workshop and removing burnt out windings, cleaning the slots, rewinding with super enamelled copper winding wire as per existing gauge and size, varnishing and drying complete, reassembling with pump, replacing the ball bearings as per existing size and make, transporting to site and refixing at original position, and connecting the pump set electrically and mechanically, testing for satisfactory working all as directed. Note : Dead flanges with nuts, washers and gaskets etc shall be provided by the contractor and unit rate quoted shall deemed to include the cost of the same. 198 Disconnecting the defective Jockey pump set of capacity 20 HP,from the system,shifting to civil workshop, dismantling the pump and removing defective/worn out parts like ball bearings, impeller nut, gland packing shaft sleeves, GM bushes, gaskets set, GM impeller and reassembling the pump by replacing the unserviceable parts with new ones, transporting to site and refixing at original position and connecting the pump set electrically and mechanically, testing for satisfactory working complete all as specified and directed.Note: Cost of minor spares like washers grease, cotton waste, gasket set, gland packing etc shall be deemed to include in the unit rate quoted and shall not be paid extra. 199 M&L for painting of OH tank of capacity 20000 gallon upto 18 metre staging height with Apex paint of make Asian/Burger/Dulko including scrabbing of old paint and making smooth the surface complete all as specified and directed. Note - (i) Painting to be done on outer surface of OH Tank from ground level to dome portion including stair case.(ii) Cost of required T&P shall be included in the quotated rates. 200 Supply and fixing with replacement of ladder inside the UG sump etc made out of MS channel, angle iron, flat iron of any size including drilling of holes with and including nuts, bolts and washers etc, as required, including painting with two coats of synthetic enamel paint over a coat of red oxide paint complete all as specified and directed. 201 M&L for painting of Raising main, Delivery main, Over flow and wash out pipe line (Height of OHT approx 21.0m) as per colour code as directed by Engineer-in-chargeincluding scrapping of pipe before painting and painting with two coats of synthetic enamel paint over a coat of red oxide paint and making the arrow to show the direction and writing the Raising main, Delivery main, Over flow and wash out on the pipe line complete all as specified and directed.Note : (i) The contractor must cater for all safety arrangement i. e. safety belts/ helmet / safety harness, shoes etc for working man power and inspecting staff and no extra cost will be paid in this effect.(ii) The T&P and other necessary equipment shall be arranged/brought by contractor to complete the job at site and no extra cost shall be paid to the contractor in this effect. 202 Supply and fixing in replacement of stainless steel wire mesh of width upto 6 feet suitable on wooden frame for pump houses including drilling of holes with and including nuts, bolts and washers etc, as required,complete all as specified and directed. 203 S&F electric shock treatment chart printed on A0 size paper duly plastic laminated and fixed inside a wooden/PVC photo frame of 50mm width with 3mm sheet glass and 6mm plybood backing and suitable hanging arrangement to wall with hooks/steel chain etc, including taking down old U/S one complete all as specified and directed. 204 S&F First aid chart printed on A0 size paper duly plastic laminated and fixed inside a wooden/ PVC photo frame of 50mm width with 3mm sheet glass and 6mm plywood backing and suitable hanging arrangement to wall with hooks/steel chain etc, including taking down old U/S one complete all as specified and directed.

Key Value

Document Fees
INR 500 /-
EMD
INR 59800.0 /-
Tender Value
INR 29.90 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Notice 0 KB
Click here to download tender document Tender Document 0 KB
Click here to download tender document Tender Document 0 KB
Click here to download tender document Tender Document 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail