}

Tender For Wks Services For Improvement To Certain Smqs At Af Stn Jodhpur (Ph-Ii), jodhpur-Rajasthan

Statutory Bodies & Commissions/Committees has published Tender For Wks Services For Improvement To Certain Smqs At Af Stn Jodhpur (Ph-Ii). Submission Date for this Tender is 22-10-2024. Paver Blocking Tenders in jodhpur Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

45232258
Corrigendum : Tender For Wks Services For Improvement To Certain Smqs At Af Stn Jodhpur (Ph-Ii)
Open Tender
Indian
Rajasthan
Jodhpur
22-10-2024

Tender Details

Tender For Wks Services For Improvement To Certain Smqs At Af Stn Jodhpur (Ph-Ii)- 1 Taking down chowkats or frames with shutters (without taking off shutters from the frames) not exceeding 1.5 sqm each complete all as specified and directed 2 Taking down chowkats or frames with shutters (without taking off shutters from the frames) exc 1.5 sqmbut not exc 4 sqmeachcomplete all as specified and directed 3 Taking down shutters of any description exc 1 sqm and n exc 2 sqm complete all as specified and directed 4 Taking up or down steel tubing 15mm bore and connections includingremoving from sitecomplete all as specified and directed 5 Taking up or down steel tubing 20 mm bore and connections including removing from sitecomplete all as specified and directed 6 Supply and laying 15mm bore tubes, galvainzed steel, medium grade, with all fittings and fixed complete on walls (concealed type) and ceilings or laid in floors complete all as specified and directed.Note: Cutting chases and making good shall be measured and paid seperately 7 Supply and laying 20 mmbore tubes, galvainzed steel, medium grade, with all fittings and fixed complete on walls and ceilings or laid in floors complete all as specified and directed. 8 Supply and laying 32 mm bore tubes, galvainzed steel, medium grade, with all fittings and fixed on walls and ceilings or laid in floors complete all as specified and directed. 9 Cutting chases in stone / concrete block walling, pinning in making good to facingand pointing in CM 1:3 to ends or edge of landing steps, cills,sunshades shelves lintels , conealed water tubing etc and like girthnot exceeding 10 cm complete all as specified and directed 10 Taking down cement or cement lime plaster, any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed 11 M&L for rendering 15 mm thick in CM 1:4 on stone masonry surfaces finished even and smooth without using extra cement complete all as specified and directed. 12 M&L for rendering 15 mm thick in CM 1:6 on stone masonry surfaces finished even and smooth without using extra cement complete all as specified and directed. 13 M&L 5 mm thick plastering in CM 1:3 finished even and smooth w/o using extra cement on concrete surface of ceilings/chajja complete all as specified and directed 14 M&L forpreparation of new plastered surfaces of wall andapplying 1-2 mm thickwall care putty on plastered surrfaces making smooth surface and applying two coats of oil bound distemper over a coat of alkali-resiatant primercomplete all as specified and directed 15 M&L for preparation of new decorated plastered or unplastered surfaces of walls applying two coats of cement base paint, white or tinted,over a coat of alkali resistant primer on wall surfaces complete all as specified and directed 16 M & L for three coat of white wash on new surface of ceiling including preparation of new surfaces complete all as specified and directed 17 M&L for preparation of old plastered orunplastered surfaces of walls including brooming down or steel wire brushing ; scraping down smooke soot, moulds, moss and efflorescents salts and trading oil and greasy spots and applyingone coat of white wash complete all as specified and directed 18 M&L for preparation of old plastered or unplastered surfaces of ceilingincluding brooming down or steel wire brushing ; scraping down smooke soot, moulds, moss and efflorescents salts and trading oil and greasy spots and applying one coat of white wash complete all as specified and directed 19 M&L for complete removal of old treatment by mechanical meansfrom wallsand applying 1-2 mm wall putty & sanding-smoothiningplastered surfaces prepatatory to distempering and applying two coats of oil emulsion distemper white or tinted over one coatofprimer by pump roller applicatorcomplete all as specified and directed 20 M&L for preparation of old plastered orunplastered surfaces of walls and applying two coats of oilemulsion distemperwhite or tinted over a layer of wall putty including removing existing nails, if any, any Nos and filling the disturbed surface/holes making smooth surface complete all as specified and directed 21 M&L for preparation of old decorated plastered or unplastered surfaces of walls applying one coat ofcement base paint, white or tinted complete all as specified and as directed 22 M&L for preparation of old painted steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying one coat of synthetic enamel paint complete all as specified and directed 23 M&L for preparation of old painted wooden surfaces of any description, over 10 cm in width or girth, not otherwise described and applying one coat of synthetic enamel paint complete all as specified and directed 24 Demolition of brick work or stone masonary built in cement mortarcompletecomplete all as specified and directed 25 M&L for PCC 1:3:6 Type C1 20 mm graded aggregate block masonarywith solid blocks exc 10 cm in widthand setting in cement mortor 1:6complete all as specified and directed 26 S&F 18mm thick solid PVC board plain colour (any colour as approved by GE) sheet having density of 600 kg/CBM of densityas in kitchen cabinets including powder coated M.S W hinges 50mm x 58 mm x 19mm with screw complete all as specified and directed 27 S&F 75mm size Brass handles, cast type, polished bright for kitchen cabinets complete all as directed 28 S&F pressed steel frames105 X 60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc completeall as specified and directed 29 S&F pressed steel framesof size 125 X60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etccomplete all as specified and directed 30 S&F factory made steel windows with side hung shutters including projecting type hinges with steel handle and steel peg stay complete with glazing bars dovetailed or welded complete all as specified and directed 31 S&F factory made steel windows with side hung shutters including projecting type hinges with steel handle and steel peg stay complete without glazing bars complete all as specified and directed 32 S&F Framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors;ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed 33 S&F 35 mm thick factory made second class hard wood plain framed panelled shutter (two panel with lock rail and panel of 9 mm BWP commerical ply or 12 mm veneered particle board with commercial veneering on both face .The size of rail and stile as per IS: 1003 (Part-1) kiln seasoned and chemically pressure treated complete all as specified and directed 34 S&F 35 mm thick factory made , second class hard wood skeleton shutters, open rebated and prepared to receive glass, gauze etc (without sash bars ) edges of framing plain chamfered or rounded fitted with cut and mitred beads for securing glass etc sizes of members of shutters as specified in SSR Part-I section 8 clause 8.24 (a) kiln seasoned and chemically pressure treated supplied and fitted to chowkats complete all as specified and directed 35 S&F Fiber Glass Reinforced plastic (FRP) Door Frames of cross section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminte shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame including fixing with using anchor bolt as per manufacturing instructions complete as specified by the manufacturerand as directed Make: Rajshree / Sintex / Duroplast / Accucel / (Accura - Polytech) 36 S&F 30 mm thick Fiberglass Reinforced Plastic (F.R.P.) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF)/Polystyrene foam to be used as filler material through out the hollow panel, casted monolithically with testing parameters of F.R.P. laminate conforming to table 3 of IS: 14856 complete all as specified by the manufacturer as directed Make: Rajshree / Sintex / Duroplast / Accucel / (Accura - Polytech) 37 M&L for framed work as in door or gates of angle or other section with gusset plate rails braces, chajja, cooler stand, window etc complete drilled for fixing of steel sheeting or other covering . Doors etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings(exclusive of steel sheeting or other covering running rails and guides) and hanging also fastening and fixing complete grade Fe-290 (Gde E-165) complete all as specified and directed 38 S&F factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 45 x 85 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/lugs/SS dash fasteners of required dia and length complete as per direction.(M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. 39 S&F providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 35mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moistureproof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, Including stainless steel butt hinges and necessary S.S screws all as per direction . 40 M&L for preparation of new steel surfaces of any description, over 10 cm in width or girth, not otherwise described priming with red oxideand applying two coats of synthetic enamel paint complete all as specified and directed 41 M&L for preparation of new wooden surfaces of any description, over 10 cm in width or girth, not otherwise described priming coat with pink primer and applying two coats of synthetic enamel paint complete all as specified and directed 42 Cutting holes in brick walls in cement mortar for insering holdfasts and making good dismantled portion incement mortar 1:3 or cement conrete 1:2:4 type B-1 as required exc half brick but notexc one brick complete all as specified and directed 43 S&F 200 mm long aluminium, anodized, barrel tower bolts of extruded section and fixed all as specified and directed 44 S&F 300 mm long aluminium alloy anodized silding door bolt with haspstaple (bolt type ) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding boltsof extruded sections or cast aluminiumalloy complete all as specified and directed 45 S&F for 100 mm long butt hinges, medium weight stainless steel complete all as specified and directed 46 S&F aluminium handles, cast type, anodized, of size 150mm complete all as specified and directed 47 S&F 300 mm, mild steel, ordinary rat tail rod pattern springs including roller and roller plate completeall as specified and directed. 48 S&F floor door stopper overall length of cover plate 150 mm long of aluminium alloy body and tongue, anodized, with hard drawn steel spring, fixed in floor complete all as specified and directed 49 Resecuring or easing & adjusting without taking down shutters of any description exc 1 sqm and n exc 2 sqm each complete all as specified and directed 50 S&Fin repairs aluminium handles, cast type, anodized, of size 150mm complete all as specified and directed 51 S&F in repairs 300 mm long aluminium alloy anodized silding door bolt with haspstaple (bolt type ) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding boltsof extruded sections or cast aluminiumalloy complete all as specified and directed 52 S&F in repairs 200 mm long aluminium, anodized, barrel tower bolts of extruded section and fixed complete all as specified and directed. 53 Welding in repairs exc 2.5 cm & n exc 5 cm in length & thickness of metal n.exc 6 mmcomplete all as specified and directed 54 S & F stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of apreture 1.4 mm & fixed with stainless steel wire staples fixed complete all as specified and directed. 55 S & F in repair stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of apreture 1.4 mm & fixed with stainless steel wire staples fixed complete all as specified and directed 56 M&L for hacking out old broken glass (any thickness, size, quality or description) from metal frame glazed with putty including punching or drilling out old glazing pin/spring, clips and providing new ones complete all as specified and directed. 57 S&F sheet glass 3 mm thick, ordinary quality and glazing with oil putty or wooden beads supplied with shutters in square n.exc. 0.5 sqm in each pane complete all as specified and directed 58 S&F in repairs vitreous china wash basin, white, flat back, size 550 x 400mm including brackets, cutting for and pinning in ends of brackets or erecting stand, brass chromium plated perforated waste coupling/ fittings 32 mm dia with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed and PVC waste pipe of 32mm bore and of suitable length,15mm borepillar tap, cast copper alloy with capstan heads, chromium plated, screwed down high pressure, with or without lettered ‘Hot’ or ‘Cold’ with long screwed shanks and fly nuts, screwed for iron pipecomplete all as specified and as directed 59 S&F in repair single mirror bath roomcabinet moulded body and framed (made from strong and fine quality ABS plastic ) with hinged door of size 16 x 12 x 6 white or ivorycolour fixed on wall with appropriate rawl plugs complete all as specified and directed .Make : Prayag/Polytuff 60 S&F 500 litres capacity rotational moulded polyethylenewater storage tank white coloured(cylindrical vertical with closed top), hoisted and fixed in position all as specified in SSR Part-I, connecting up pipes including 20 mm bore plastic ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic plastic ball screwed for iron pipe and fixed. (Minimum weight of ball valve - 210 gms)complete all as specified and directed 61 S&F in repair sink with drainage board made of stainless steel 1.00mm thick kitchen or laboratory with plugs, washers and wastes, including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915 mm x 460 mm, bowl size 410mm x 330 mm x 160 mm and PVC waste pipe of 32mm bore of suitable length completeall as specified and directed 62 S&F in repairs stainless steel plate rack, thickness of sheet 0.63mm thick SS(AISI 304) of standard pattern of size 750 x 600 x 250mm complete all as specified and directed 63 S&F in repairs, EWC vitreous china wash down water closet pan (pedestal pattern), white, with and including plastic water closet seat, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device fixed complete all as specified and as directed 64 S&F in repair brass chromium plated health faucet of 15 mmbore including PVC connetionpipe of suitable length complete all as specified and directed 65 S&F in repair stainless steel toilet paper holder chromium plated (CP)fixed to walls with CP brass screws complete all as specified and directed 66 S&F in repairs vitreous china squatting pan, ‘Orissa’ pattern, size 580 mm x 440 mm, white with integral foot rests, including PVC P trap, embedded and set in PCC 1:5:10 type E-2 and making good to floor including removing rubbish complete all as specified and directed 67 S&F in repairs PVC valveless, syphonicaction type, flushing cistern, low level, dual type 10 litres capacity, white, with inlet, ball valve, float and handle including brackets complete all as specified and directed 68 S&F in repair 15 mm bore bib taps, cast copper alloy, chromium plated, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed (Minium weight 15 mm-450 gms) 69 S&F in repair, 15 mm bore stop valve, fancy type, chromium plated, screwed down, high pressure with crutch or butter fly handle, screwed both ends for iron pipe or for unions (Minium weight 15 mm-400 gms) complete all as specified and directed 70 S&F in repairs 15 mm bore stop valve, fancy type, chromium plated with long shank and cup (concealed type), screwed down, high pressure with crutch or butter fly handle, screwed both ends for iron pipe or for unions complete all as specified and directed(Minium weight 15 mm-450 gms) 71 S&F in repairs 20 mm dia gun metal globe or gate valve with iron wheel head screwed both ends for iron pipes complete all as specified and directed(Minium weight 15 mm-450 gms) 72 S&F in repairsbrass chromium plated shower rose of 125 mm size with swivel joint including fixing to steel pipe or union complete all as specified and directed (Minium weight 15 mm-235 gms) 73 S&F in repairs PVC connection 15 mm size withPTMT nuts of length 450 mm complete all as specified and directed 74 S&F in repairs CP tubular towel rail, 20 mm dia, D type, 60 cm long between flanges complete all as specified and directed 75 S&F in repair CP grating 100 mm dia complete all as specified and directed 76 S&F in repairs stainless steel soapdish made of stainless steel 1.00mm thick, approximate size 100x75mm fixed withplugs with chromium plated brass screws complete all as specified and directed 77 S&F in repair glass corner shelf (set of three)fixed with and including chromium plated brass screws and wooden/plastic cleatscomplete all as specified and directed 78 Dismantling of cast iron or reinforced concrete drain pipe, jointed in cemented mortar and taking out of trenches or in vertical position of internaldia 100 mm & lessincluding fittings complete all as specified and directed 79 S&F PVC (SWR) gully traps of size 125/110 mm,setting and jointing with solvent cement complete all as specified and directed 80 S&FPVC (SWR) pipes 110 mm dia single socketed, in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed Note: Rate quoted shall include execution of necessary earthworkviz excavation, RfR, removal as directed andnothing extra shall be paid on this account 81 S&FPVC (SWR) pipes 110 mm dia single socketed, in any length with rubber ring joints fixed in walls with and including fixing MS clamps of size 25x3 mm complete all as specified and directed 82 S&F PVC (SWR) pipes 75 mm dia single socketed, in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed Note: Rate quoted shall include execution of necessary earthworkviz excavation, RfR, removal as directed andnothing extra shall be paid on this account 83 S&FPVC (SWR) pipes 75 mm dia single socketed, in any length with rubber ring joints but fixed in walls with and including fixing MS clamps of size 25x3 mmcomplete all as specified and directed 84 S&F PVC (SWR), junction single, (Single T) with door 110 mm dia equal or unequal complete all as specified and directed 85 All as per item No.84 but 75 mm dia 86 S&F for PVC (SWR) door bends 110 mm dia complete all as specified and directed 87 All as per item No.86 but 75 mm dia 88 S&F for PVC (SWR) vent cowl 110 mm dia complete all as specified and directed 89 S&F for PVC (SWR) vent cowl 75 mm dia complete all as specified and directed 90 S&F PVC (SWR) junction double, (double T), equal or unequal provided with access door 110 mm diacomplete all as specified and directed 91 S&F forPVC (SWR), 75mm dia of floor trap, with grating including jointing with solvent cement complete all as specified and directed . 92 Demolition of any old unserviceableroof tiles/ padding etc. as in roof treatment including existing water proofing treatment of any description to expose the RCC Slab of roof complete all as specified and directed . 93 Wire brushing and cleaning top surfaces of terrace or cement concrete including dismantling existing old roof treatmentand junction of parapets complete all as specified and directed 94 M&L10 mm thick screed bed with CM 1:3with water proofing compound @ 3% by weight of cement surfaces finish even and smoothusing without extra cement applied on padding concrete when concrete is stilll green complete all as specified and directed Note: Water proofing compound shall be measured and paid seperately 95 M & L prepration of surface and providing Waterproofing membrane moisture cured, Polyurethane elastomeric liquid membrane waterproofing coating cold applied with brush/roller, with an elongation of >500% and tensile strength of 2 MPa as per ASTM D 412, 90 % Solid Content, shore A Hardness of min 50 as per ASTM D 2240, The system includes final base preparation as per note given below, PU primer application at8Sqm/L andapplying Home Sheild PU ELASTOSEAL NON-UV 1K or approved equivalent in two coats at 1.8 kg per Sqm providing 1.5 mm DFT, complete as per Manufacturer specifications, Waterproofing membrane to be terminated on parapet wall in a V groove of size 25 mm x 25 mm atleast 300mm aboveFFL whichshould be sealed with Polymer Mortar complete all as specified and directed for work in building/structure of any height, Completed as per manufacturer instruction.Make : Berger, Sika, Fosroc, STP, PIDLITE, Dr. FIXITNote: Surface Preparation:(i) The surface to be treated should be sound and free from all types of dirt, dust and debris. Clean surface by brushing, scraping or chipping to eliminate all defective materials and foreign matter. Proper surface preparation needs dry mechanical grinding to expose base Substrate. Making of angle fillets(75mmx75mm) all around the periphery of the wall with polymer modified mortar using SBR Latexii) All construction joints and cracks >1mm shall be treated by cutting V groove and filling with polymer modified SBR Latex and reinforced with geotextile membrane dipped in PU liquid Membrane before the 1st coat application. 96 M&L APP modified membrane minimum weighting 3 Kg/Sqm and minimum 3mm thickwith polysternon woven polyster reinforcement ( weight not less than 150 gms/sqm )shall be laid by torch application method and overlapped by 100 mmin all sides including applying evenly a tack coat of industrial bitumen 85 / 25 @ 1.20 Kg Sqm per including cleaning of surface complete all as specified and directed.(Accessible roofs) 97 M&L PCC tiles 25cm x 25cmx 22mm thick, with grey cement and pigments machine pressed; set jointed and pointed in neat cement slurry in floors, and cut and polished including 20 mm thick screed bedding layer in C:M 1:3 complete all as specified and directed 98 Supply only integral water proofing compound ISI marked complete all as specified and directed 99 M&L PCC 1:3:6 type C-0 (using 12.5 mm graded stone aggregate) as in roof padding (average thikness 50mm thick) complete all as specified and directed 100 M&L for water proofing treatment of sunken floor of WCs bathroom etc by applying of the following procedure :-(i) Cleaning of sunken floor surface with mechanical means i.e wire brush / air blower etc and remove all loose/unsound material dirt dust etc. (ii)Applying cement slurry mixed with acrylic based polymer modified cementious composite compund coating Hydroproof Xtra of FOSROC /Equivalent of Dr Fixit of Pidilite industries Ltd in the ratio 1:2:4 (one part of acrylic polymer : two part of water and four part of cement) (iiii) First layer of cement slurry @0.444 kg /sqm mixed with acrylic based modified cementious composite compund @0.222 litre/sqm and allow it to air dry for 4 hour.(iv) Second layerof cement slurry @0.222 kg /sqm mixed with acrylic based modified cementious composite compound @0.111 litre/sqm and allow it to air dry for 4 hour followed with water curing for 48 hours (v) 200 micron thick polythen film shall be pasted with help of adhesive over treatment complete all as specified and directed. Note:- Joints of WC/Trap/Soil waste shall be properly sealed with sealing compund . Testing of all traps and joints and sunken slab shall be done as per IS-1742 before filling and tiling work as directed by Engineer-in-Charge. 101 M&L for plain cement conrete 1:5:10 type E-2 (using 20 mm graded broken bricks aggregate ) as in foundation and mass concrete complete all as specified and directed 102 Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing from site and rubbish off the premises complete all as specified and directed 103 M&L for joint freenon skid ceramic tiles, coloured, 7 to 8 mm thick in floors etc. area of each tile exc. 0.06 sqm but n. exc. 0.11 sqm, set & jointed in neat cement slurry & pointed in white or coloured cement to match over and including 15mm thick screed bed in CM 1:6 complete all as specified and directed 104 M&L for joint freenon skid ceramic tiles, coloured, 7 to 8 mm thick in floors (square/rectangular) area of each tile exc. 0.18 sqm but n. exc. 0.36 sqm, set & jointed in neat cement slurry & pointed in white or coloured cement to match over and including 15mm thick screed bed in CM 1:6 complete all as specified and directed 105 M&L for glazed ceramic tiles, coloured, 450 x300 x 7mm thick on vertical surfaces such as skirtings, dados and risers to steps etc, set & jointedin neat cement slurry & pointed in white or coloured cement to match over and including 10mm thick rendering in CM 1:4 on stone or brick masonry surfaces complete all as specified and directed 106 M&L for glazed ceramic tiles, coloured, 600 x 600 x 7mm thick on vertical surfaces such as skirtings, dados and risers to steps etc, set & jointedin neat cement slurry & pointed in white or coloured cement to match over and including 10mm thick rendering in CM 1:4 on stone or brick masonry surfaces complete all as specified and directedNote: Skerting shall be fixedflushed with plaster 107 M&L for machine cut kota stone slab flooring 20 -25 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigmenst to match the shade of the slab including rubbing and polishingincluding 20 mm screed bed or bedding layer in cement mortar 1:4 complete all as specified and directed 108 M&L for Kota stone slab 20-25 mm thick in riser/tread (one piece slab for each tread/risers) including grooving in edge (two lines), set & jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10 mm thick renedering in CM 1:4 on stone masonary surfaces complete all as specified and directed 109 M&L for Granite stone as in cooking platform (of any type),18mm to 20mm thick machine cut one stone,including 25 x 25mm granite leaping with round edge fixed at external face of platform to splash out water etc bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing over 20 mm thick Screed bed or bedding layerin CM 1:6 complete all as specified and directed 110 M&L Greenmarble work 18 to 20mm thick (table rubbed and mirror polished) in one piece of stone in steps, jambs, pillars, window cills and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade of marble over 15 mm thick Screed bed or bedding layerin CM 1:4 complete all as specified and directed. 111 Demolition of cement concrete (unreinforced) in ground floors and pavings n. exc. 15 cm thickness (below or above ground level)complete all as specified and directed 112 M&L for 25 mm thick PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate in sub floors complete all as specified and directed 113 M&L 75 mm thick PCC 1:4:8 type D2 using 40mm graded stone aggregate in sub base of floor complete all as specified and directed 114 M&L 75 mm thick PCC (1:3:6) type C2 (using 40mm graded stone aggregate) as in plinth protection finished surface even and fair without using extra cement complete all as specified and directed 115 M&L for providing and laying 60 mm thick factory made chamefered edge cement concrete paver block of M-35 grade with approved colour design & pattern as in footpath, parkslawns, drive ways or light traffic parking etc of required strength thickness & size shape made by table vibratory method using PU mould laid in required colour & pattern over and including 50 mm thick compacted bed of fine river/ manufacturing sand comapcting and proper embedding / laying of interlocking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator filling the joints with sand and cutting of paver blocks as per required size and pattern finishing and sweeping extra sand complete all as specified and directed 116 Demoliton of reinforced cement concrete of any description for roofs, floor (Other than ground floor), beams, staicases, landing, chajjas and similar work complete all as specified and directed 117 M&L RCC Nominal mix Type B 1, 1:2:4 (20 mm graded aggregate) for slabs supported on walls, beams and colimns in floor, roofs, landings, balconies, deck slab and in shelves and the like complete all as specified and directed. 118 S & FPre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering / chajja /cladding to wall, fixed with self tapping screws complete all as specified and directed. 119 S&F MS TMT bars 10mm dia and over, cut to length, bent shape required, including cranking , bending, hooking etc and binding with MS wire 0.9mm dia (annealed) complete all as specified and directed. 120 M&L for Formwork to soffits of suspended slabs for rough finished surfaces of concrete such as roof slabs, floor slabs, landing and similar work: not exc 200 mm thick (horizontal or sloping)complete all as specified and directed 121 M&L for Formwork to edges of concrete flats, treads, breaks in floors, concrete railings, opening in concrete walls, floor and roofs n.exc 20 cm wide and sides of RCC /PCC bands in walls, horizontal or sloping and similar work exc 10 cm but n.exc 20 cm wide for rough finished complete all as specified and directed. 122 S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings, directions of Engineer-in-Chargeall as specified and as directed Note :- S& F of 4mm thick glass & SS wire meshpayment will be made separately 123 S&F Aluminium windowshutters powder coated of any colour ( thickness of powder coating not less than 50 micron), side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) completeallasspecified and directed 124 S&FAluminium deco grill size 100mm x 100mm and 10mm dia powder coated (Minium thickness of powder coating not less than 50 mocron)of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening complete all as specified and directed 125 M&L 4 mm thick sheet glass, ordinary quality n exc 0.5 sqm in each pane complete all as specified and directed. 126 S&F louvers type aluminium ventilator aluminium frame size 63.50 x 38.10 mm, thickness 1.28 mm including metalic louvers slits to hold glass strip of size as per opening andincluding 4.0mm thick pin head glass as per size & louvers ventilator complete all as specified and directed. 127 S&F in repairs 25mm dia stainless steel SS Grade - 304, 1mm thick curtain rod with and including stainless steel brackest fancy type end caps, stops etc complete all as specified and directed 128 M&L for providing and injecting chemical emulsion for post construction anti termite treatment along external wall where the apron is not provided using chemical emulsion at the rate of 7.5 ltr per sqm of the vertical surface of the sub structure to a depth of 300 mm including excavating channel along the wall and rodding etc complete all as specified and directed 129 M&L Removing building materials etc. (other than spoil payable under respectiveitems) to a distance ofexc 3.00 KM (outer side MD land as per discretion of contractor) beyond the lead included in the rates, including loading, unloading and stacking at the destination complete all as specified and directedNote: No extra lead shall be paid beyond 3.0 KM, all debris shall be reomved at the discretion of contractor) 130 E/M Works 131 Taking down carefully copper/aluminum point wiring (Light/ fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc, stacking at site for reuse or removing materials to store for keeping in for taking credit and making good the disturbed surfaces / walls/ floors etc complete all as specified and directed 132 M&L for channel or grooves cutting upto a depth of 2.5 cm and width not exc 15cm into brick/concrete/stone masonary walls, with or without reinforcement and trimming surface as required, including concealing PVC conduit 20/25mm dia with required accessories (like junction boxes/bends etc) and making good by plastering in CM1:4 , applyingof approved quality white putty for making good with smooth finish to match with the existing specification of wall surface all specified and directed . 133 M&L for point wiring with 1.5 Sqmm, multi-stranded copper conductor single core, FRLSH, PVC insulated and unsheathed cable for phase and neutral, including 1.5 Sq. mm PVC insulated unsheathed multistranded copper conductor single core cable as earth continuity conductor (in green color) connected to common earth dolly, drawn in surface/concealed conduit heavy duty (HMS Grade), GI terminal boxes not less than 1.0mm thick fixed flush to wall surface, covered with & including 3 mm thick plastic laminated sheet top cover or including modular plates of required size for mounting switch and sockets etc. complete all as specified and directed for following : -Note : Quoted rates shall deem toincluded cost of PVC conduit, modular plate for mounting switches, sockets & regulators as required at site. 134 One light / fan point controlled by one switch one way. 135 One light point controlled by two Nos 5 Amps switch two way 136 One 3 pin 5 Amp switch & socket outlet on same board with other switches. 137 One 3 pin 5 Amp switch & socket outlet on Independant board. 138 One bell point controlled by one switch 5 Amps bell push. 139 All same as per item ser No 132 here-in-above but wiring using 2.5 sqmm multi-stranded copper conductor, single core, FRLSH, PVC insulated and unsheathed cable, including 2.5 Sq. mm PVC insulated unsheathed multistranded copper conductor single core cable as earth continuity conductor (in green color) connected to common earth dolly for 6 pin, 15/16 Amps socket outlet on independant board. 140 All same as per item ser No 132 here-in-above but wiring using 4.0 sqmm multi-stranded copper conductor, single core, FRLSH,PVC insulated and unsheathed cable, including 4.0 Sq. mm PVC insulated unsheathed multistranded copper conductor single core cable as earth continuity conductor (in green color) connected to common earth dolly for two pin earth metal clad plug & socket point for AC/Geysers. 141 S&F switch modular single pole one way 6 Amps 230 volt 1 module complete all as specified and directed 142 S&F switch modular single pole two way 6 Amps 230 volt 1 module complete all as specified and directed 143 S&F switch modular single pole one way 16 Amps 230 volt 1 module complete all as specified and directed 144 S&F Socket modular 6 Amp 2/3 pin combined two module complete all as specified and directed 145 S&F Socket modular 6&16 Amp 2/3 pin combined two module complete all as specified and directed 146 S&F Bell Push modular single pole one way 6 Amps 230 volt 1 module complete all as specified and directed 147 S&F Stepped type modular electronic fan regulator, socket size, two module, flush type 230V AC complete all as specified and directed 148 S&F Ceiling rose surface bakelite 65x50mm three terminal complete all as specified and directed 149 S&F Lamp holder insulated PVC/Polycarbonate/bakelite body, fixed on PVC round or square box using necessary screw & gutti complete all as specified and directed. 150 S&F electronic Bell Bul-Bul music, 230 volt, single phase complete all as specified and directed 151 Taking down carefully Ceiling fan/Exhaust fan by disconnecting electrical connections, unsecrewing from position, dismantling blades, stacking carfully at site for reuse of serviceable fans complete all as directed and specified. 152 Taking down carefully Electric geyser by disconnecting electrical connections & water connections unsecrewing from position, stacking carefully at site for reuse of serviceable geyser complete all as specified and directed. 153 Taking down carefully Enegry meters by disconnecting electrical connections, stacking carfully at site for reuse of serviceable meters or deposit to E/M store if new meter provided against replacement complete all as specified and directed 154 Fixing only light fitting any type, connecting up with twin core PVC insulated and PVC sheathed flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. Note :Serviceable light fittings taken down against item No 130 shall be used at site as directed by Engr-in-charge. 155 Supply and fixing LED light fitting wall /roof mounted, Aluminium housing, 1 x 20 watt including LED tube with driver complete suitable body robust, corrosion resistant, superior finish and without any cracks or through holes. The system wattage of fitting should not be more than 20 watt ± 10%, surge protection of minimum 2 kV power factor should be more than 0.90 cool white colour, total harmonic distoration (THD) should not be more than 15%, lumen output should not be less than 90 lumens per watt, total input voltage range 140-280 V AC, colour rendering index should not be less than 80, corelated colour should be minimum 6000 degree kelvin complete all as specified and directed. 156 Supply and fixing LED light fitting wall /roof mounted, Aluminium housing, 1 x 9/10 watt including LED tube with driver complete suitable body robust, corrosion resistant, superior finish and without any cracks or through holes. The system wattage of fitting should not be more than 10 watt ± 10%, surge protection of minimum 2 kV power factor should be more than 0.90 cool white colour, total harmonic distoration (THD) should not be more than 15%, lumen output should not be less than 90 lumens per watt, total input voltage range 140-280 V AC, colour rendering index should not be less than 80, corelated colour should be minimum 6000 degree kelvin complete all as specified and directed. 157 Supply and fixing Building security light fittings, with pressure die cast aluminium housing, suitable for 25 W LED,complete pre-wired, including lamp and suitable bracket for fixing light on wall or any indicated locaction complete all as specified and directed Make:Havells Cat No: ENDURAPEARLSL25W or equivalent model approved makes. 158 S&F LED light fitting 1 x 10W bulkhead luminaires includingLED light, driver holder, perfect interior and exterior application connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. 159 M&L for cutting holesthrough wall of 300mm diameter for preaparing opening for fixing exhaust fan 300mm sweep, making good to damaged surface of wall, make a smooth circular surface and match with specification of existing wall complete all as specified and directed 160 Hanging only ceiling fans, 1200mm sweep, complete with three blade, down rod, accessories and making connection from ceiling rose or connector to fan using three core 0.75sqmm copper stranded conductor PVC insulated and PVC sheathed flexible wire and including minor repair of ceiling fans (like replace of rusted nut bolts, denting of blade, cleanig of dust etc) complete all as specified and directed. NOTE:Fan taken down against item No 145 shall be refixed under this item after completion ofcivilrepair work 161 Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor(BLDC) connecting up including provision of flexible PVC conduit from ceiling rose or connector to fan to cover PVC cable including marking of MES number and fixed in position as recommended by manufacturer complete all as specified and directed. 162 Fixing only exhaust fan 300mm sweep, Steel/PVC body AC single phase 230V of size 300m using 4 Nos 10mm x 100mm long wall fasteners, nut and washers and connecting up using flexible three core 0.5sqmm copper stranded conductor PVC insulated and PVC sheathed flexible wire through PVC flexible conduit from ceiling rose/connector to fan and including minor repair of fans (like replace of rusted nut bolts, denting of blade, cleanig of dust etc) complete all as specified and directed. NOTE: Exhaust Fan/wall fans taken taken down against item No 145 shall be used after complete civilrepair work 163 Fixing only and connecting electric meters upto 100 amps with necessary incomming and outgoing copper cable using suitable size copper alloy thimbles/lugs and numbering of connected married accomodation number complete all as specified and directed. Note : Serviceable meter taken down against item No 146 shall be refixed under this item 164 Installation ofElectric Storage type water heater (Geysers) 25/50 Ltr capacity with standard fixing accessories including suitable size wall fastener bolts & Nuts, gutties etc complete all as specified and directed. NOTE:Serviceable geyser obtained against item No 147 shall be refixed under this itemafter cleaning and necessary minor repairs. 165 S & F Exhaust fan 300 mm sweep, copper wounded, four blade, metal body, BEE approved/ISI marked, air delivery shall not be less than 230 CFM, mounted in suitable opening arrangement with louvers shutters, suitable for operation on 240 volt, single phase, 50 cycle per second, AC supply and connecting up using flexible cord wire 3 core using PVC flexible conduit from ceiling rose or connector to fan to cover PVC cable including marking of MES number and fixed in position as recommended by manufacturer complete all as specified and directed. 166 M&L for Sub main wiring comprising two runs of 6.0 Sq.mm main Phase-Neutral supply cable alongwith one run of single core 6.0 Sq.mm for continuous earth wire in green colour as per IS, single core FRLS PVC insulatedflexible multistranded copper conductor 1.1 KV grade drawn through & including PVC grey conduit heavy duty with necessary accessories (like bend, juction boxes etc) including taking down old unsv submain wiring complete all as specified and directed (for SMQ)Note: Two runs of cable, one run of earth wire, conduit shall be measured as one RM unit 167 Supply and replace sheet metal enclosures with socket plug top, and MCBs single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB upto 16 Amps, 240 Volt capacity fixed flush to wall surface including making good to damaged surface of wall to match with existing specification and tested on completion including taking out old complete all as specified and directed 168 Supply and replace sheet metal enclosure distribution board for 240 volts, 12 way horizontal type, double door, single pole and neutral with 200 Amps rated neutral copper bus bar for housing MCB and blank plates and fixed flush in wall surface, and tested on completion including taking out old complete all as specified and directed 169 M&L for MCB SPN/DP RCBO 40Amps 240 volts, 30 mA capacity and 10 kA rupturing capacity providing in DB complete including connection & testing complete all as specified and directed Make- Havells cat part no-DHCEACSN2030040 or equivalent as per approved makes 170 Supply and fixing MCB single pole 6-32 Amps, 240 volts, 10 kA rupturing capacity providing in DB complete including connection & testing complete all as specified and directed 171 M&L for wiring with TV coaxial RG-06, electrolytic grade solid annealed copper conductor having single strand of 0.7 mm dia, PVC insulated, aluminium foiled and aluminium wire braided, overall PVC sheathed cable complete including concealed PVC conduit 20mm dia from TV Socket to dish antena on roof of building complete all as specified and directedNote : 20mm conduit pipe inside building shall be concealed in wall surface and from external surface duly fixed with GI Saddles is deemed to be included in this quoted rates. 172 Supply, installations, testing and commissioning factory made indoor cubical type panel box for fixing energy meter, 4 each separate compartment for each energy meter, fabricated using 2.0mm thick MS sheet, duly provided with 8 mm thick flame proof backelite/hylem sheet for mounting Enegry meters in each compartment, and provision pre-wiring and fixing of incomming and outgoing control MCCB/MCBs, each meter compartment shall provided with front opening hinged door with internal or external locking arrangment. MS box duly paintedwith two coats of powder coated Semense gray paint over a coat of red oxide primer. The meter box shall designed and fabricated for fixing 01 x MCCB 100 Amps 4 pole as incommer and vertical or horizontal copper busbar chamber for taking connection to incommer MCB of each meter by using 10 Sqmm, PVC insulated multistranded copper conduction wire single core in proper color codes complete all as specified and directed including fixing of following items :-(a) MCCB 100 Ams, 4 pole, 16 kA,(Ics=100 % of Icu) -as incommer(b) Copper Busbar 200 Amps duly sleeve insulated for set of 3 phase, 4 wire system - 01 Set(c) 2 runs of PVC insulated single core multistraded FRLS grade copper wire for conncetion from busbar to input supply of Each energy meter by using necessary copper alloy lugs/thimbles.(d) MCB SPN 63 Amps on each meter incomming pre-wired-4 Nos (One incomming each meter)(e) MCB SPN 40 Amps on each meter outgoing pre-wired-4 Nos (One outgoing on each meter)(f)LED Indicator lamp (R,Y,B)- Set of Three.Note : Quoted rate includes the cost of all necessary clamp, wall fasters for fixing meter box on wall surface and re-fixing energy meters & making all incomming and outgoing electrical connections with existing input cable and outgoing wires. 173 Material and labour for earthing complete with Galvanized Steel earth plate electrode 600 x 600 x 6mm thick buried directly in ground (earth pit not less than 2.25 M deep below ground level) with top edge of the plate not less than 1.5 M below normal ground level and filled with 15cm thick alternate layers of charcoal and salt, connected & including GI wire earth lead 4.0mm dia by means of bolts, nuts, check nuts and washers made of galvanized iron protected by 15mm dia GI Pipe (light grade). Earth plate shall be surrounded by alternate layers of charcoal or coke and common salt in 15cm thick in layers & 15cm of widht all around of earth plate including 20mm dia GI light grade pipe for watering and including funnel, wire mesh, necessary earth work in any type of soil, Pre-cast RCC cover duly reinforced with 8mm dia TMT Bar @150 mm c/c both ways, one lifting handle made of 8 mm dia TMT bar embedded in cover slab, Earth Pit of PCC (1:3:6) type C2 (using 20mm graded crushed store aggrgate)complete all as specified and as shown in electrical plate No-3 of SSR Part-I including testing on completion.Note:- (i)PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) The unit rate includes earthing lead & protection pipe upto 7.5 metre from top of earth plate. 174 Schedule of Credit Rs. 425352.50

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 03-10-2024 Amendment in critical date in tender document Date 12-10-2024
2 11-10-2024 amendment in tender document Other 15-10-2024
3 11-10-2024 amendment in critical date in tender document Date 15-10-2024
4 15-10-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 22-10-2024

Key Value

Document Fees
INR 2000 /-
EMD
INR 572000.0 /-
Tender Value
INR 4.97 Crore /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail