Tender For Special Rep To Bldg No Et-15 (Rangia) And Replacement Of Ascr Conductor With Ug Cable & Connected Works At Certain Unit In Changsari Mil Stn Under Ge Rangia, rangia-Assam

Statutory Bodies & Commissions/Committees has published Tender For Special Rep To Bldg No Et-15 (Rangia) And Replacement Of Ascr Conductor With Ug Cable & Connected Works At Certain Unit In Changsari Mil Stn Under Ge Rangia. Submission Date for this Tender is 26-09-2024. Wrenches and Drivers Tenders in rangia Assam. Bidders can get complete Tender details and download the document.




Tender Notice

45232126
Tender For Special Rep To Bldg No Et-15 (Rangia) And Replacement Of Ascr Conductor With Ug Cable & Connected Works At Certain Unit In Changsari Mil Stn Under Ge Rangia
Open Tender
Indian
Assam
Rangia
26-09-2024

Tender Documents

Tender Details

Tender For special REP TO BLDG No ET-15 (RANGIA) AND REPLACEMENT OF ASCR CONDUCTOR WITH UG CABLE & CONNECTED WORKS AT CERTAIN UNIT IN CHANGSARI MIL STN UNDER GE RANGIA- 1 Taking down Chowkhats or frames with shutters (without taking off shutters from the frames) not exc. 1.5 sq. m each, complete all as specified and as directed by Engineer-in-charge. 2 Taking down Chowkhats or frames with shutters (without taking off shutters from the frames) exc 1.5 sqm but not exc. 4.0 sq. m each, complete all as specified and as directed by Engineer-in-charge. 3 Demolition of Brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, complete all as specified and as directed by Engineer-in-charge. 4 Demolition of Cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for, complete all as specified and as directed by Engineer-in-charge. 5 Demolition of reinforced Cement concrete of any description and in any position not otherwise specifically provided for, complete all as specified and as directed by Engineer-in-charge. 6 Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete all as specified and as directed by Engineer-in-charge. 7 Dismantling Asbestos cement (corrugated, semi-corrugated, etc.) sheets in roof coverings, complete all as specified and as directed by Engineer-in-charge. 8 Dismantling wrought iron or mild steel work of any description not otherwise provided for, complete all as specified and as directed by Engineer-in-charge. 9 M&L for PCC 1:3:6 type C-2 (40mm graded stone aggregate) as in foundations, fillings and mass concrete including necessary formwork as required, complete all as per specified and as directed by Engineer-in-charge. 10 M&L for Reinforced Cement Concrete, M-25 (Design Mix) (20mm graded stone aggregate) in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete, complete all as specified and as directed by Engineer-in-charge. NOTE : Reinforcement & Formwork will be measured and paid separately under relevant Item. 11 M&L for Reinforced Cement Concrete, M-25 (Design Mix) (20mm graded stone aggregate) in Columns, pillars, piers, posts and struts, complete all as specified and as directed by Engineer-in-charge. NOTE : Reinforcement & Formwork will be measured and paid separately under relevant Item. 12 M&L for Reinforced Cement Concrete, M-25 (Design Mix) (20mm graded stone aggregate) in Beams, cantilevers, bressummers, lintels over 1.5m span, chajjas, complete all as specified and as directed by Engineer-in-charge. NOTE : Reinforcement & Formwork will be measured and paid separately under relevant Item. 13 M&L for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, rough finished flat surfaces of concrete, complete all as specified and as directed by Engineer-in-charge. 14 M&L for Formwork to sides of pillars, posts, struts, piers, columns and stanchions, rough finished flat surfaces of concrete, complete all as specified and as directed by Engineer-in-charge. 15 M&L for Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc., rough finished flat surfaces of concrete, complete all as specified and as directed by Engineer-in-charge. 16 S&F of TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and as directed by Engineer-in-charge. 17 S&F of TMT bars 6-8mm dia, cut to length, bent to shape required, in stirrups, spacers and binders and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and as directed by Engineer-in-charge. 18 S&F of Mild Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240, complete all as specified and as directed by Engineer-in-charge. 19 All as per Item No 18 here-in-above, but for febrication and errection only, complete all as specified and as directed by Engineer-in-charge. 20 S&F of mild steel Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165, complete all as specified and as directed by Engineer-in-charge. 21 S&F of Solid PVC Door Frame of size 50mm x 47mm made out of 5mm single side prelam PVC sheet reinforced with M.S. Square tube; complete all as specified and as directed by Engineer-in-charge. 22 S&F of Solid PVC Door Frame of size 50mm x 95mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube; complete all as specified and as directed by Engineer-in-charge. 23 S&F of Factory Made Solid PVC Moulded Door Shutter With wood free EPS, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded Prelam PVC Sheet on the front face & 2mm prelam PVC Sheet on back face; complete all as specified and as directed by Engineer-in-charge. 24 S&F of Factory made wire gauzed panel PVC moulded door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; wire gauze shall be wrapped on an additional square 8mm M.S. Solid tube and this tube shall be welded to M.S. tubes. The wire gauge shall be stretched to tighten firmly; complete all as specified and as directed by Engineer-in-charge. (Cost of wire mesh shall deemed to be included in unit quoted rate) 25 S&F of Steel windows with side hung shutters including box type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded, complete all as specified and as directed by Engineer-in-charge. 26 S&F of Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete without glazing bars, dovetailed or welded, complete all as specified and as directed by Engineer-in-charge. 27 S&F of 100 mm long Butt hinges, medium weight, cold rolled mild steel, complete all as specified and as directed by Engineer-in-charge. 28 S&F of 150 mm long Aluminium anodised, barrel tower bolts of extruded section, complete all as specified and as directed by Engineer-in-charge. 29 S&F of 150 mm long Extruded aluminium alloy handles, cast type, anodised, complete all as specified and as directed by Engineer-in-charge. 30 S&F of 250 mm long Mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate, complete all as specified and as directed by Engineer-in-charge. 31 S&F of 140 mm Overall length of cover plate double legged Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring and rubber end, fixed in floor, complete all as specified and as directed by Engineer-in-charge. 32 S&F of Mild steel 300mm long, ordinary rat tail rod pattern springs including roller and roller plate, complete all as specified and as directed by Engineer-in-charge. 33 S&F of Galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples, complete all as specified and as directed by Engineer-in-charge. 34 S&F of 3mm thick sheet glass, ordinary quality and glazing with oil putty in square not exc 0.5 sq. m in each pane, complete all as specified and as directed by Engineer-in-charge. 35 M&L for providing in patches not exc 0.50 Sqm GI wire netting 0.90mm dia and 12mm mesh lathing to wood or metal studding, joists, etc. in walls, ceilings, stanchions, beams, etc. including all laps, cutting and waste, complete all as specified and as directed by Engineer-in-charge. 36 M&L for Brickwork with Fly ash bricks, straight or curved on plan to any radius built and set in cement mortar 1:6, complete all as per specified and as directed by Engineer-in-charge. 37 M&L for Brickwork with Fly ash bricks, straight or curved on plan to any radius inhalf brick thick walls built and set in cement mortar 1:4, complete all as per specified and as directed by Engineer-in-charge. 38 M&L for Rendering 10mm thick in cement morter 1:6 on other than fair faces of brick work or concrete surfaces/ other side of lathing, finished even and smooth (without using extra cement), complete all as specified and as directed by Engineer-in-charge. 39 M&L for Rendering (Externally) 15mm thick in Cement Mortar 1:4 in two layers on other than fair faces Brick Walls/Concrete Surfaces/ other side of lathing, 5mm thick top layer mixed with WPC as per Manufactures instruction, plastered surfaces finished Even and Smooth without using Extra Cement, complete all as specified and as directed byEngineer-in-charge. NOTE: WPC shall be Measured and Paid as ‘Supply only’ under relevant Item. 40 Supply only Integral waterproofing compound, complete all as specified and as directed by Engineer-in-charge. 41 M&L for providing 75 mm thick Cement concrete type D-2, 1:4:8 (40mm graded stone aggregate) as in sub-base of floor/ path/ hardstanding/plinth protection, etc. or similar works, laid in altenate bays including use and waste of form work and finishing concrete surfaces even and rough, complete all as per specified and as directed by Engineer-in-charge. 42 M&L for providing 75 mm thick Cement concrete type C-2, 1:3:6 (40mm graded stone aggregate) as in floor/ path/ hardstanding/plinth protection, etc. or similar works, laid in altenate bays including use and waste of form work and finishing concrete surfaces even and fair, complete all as per specified and as directed by Engineer-in-charge. 43 M&L for providing 40 mm thick Cement concrete type B-1, 1:2:4 (20mm graded stone aggregate) as in base of floor/ path/ hardstanding/plinth protection, etc. or similar works, laid in altenate bays including use and waste of form work and finishing concrete surfaces even and rough, complete all as per specified and as directed by Engineer-in-charge. 44 M&L for Forming Construction (Dummy) joints 30mm deep x 10mm wide filled with sealing compound Grade A, complete all as specified and as directed by Engineer-in-charge. 45 M&L for providing Non-skid Ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm, in floors etc., laid over 20mm thick cement screed 1:6 set and jointed in neat cement slurry and pointed in white or coloured cement to match, complete all as per specified and as directed by Engineer-in-charge. 46 M&L for providing Non-skid Ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm,in vertical surface (like skirting, dado, etc.), over 10mm thick cement screed 1:3 set and jointed in neat cement slurry and pointed in white or colour cement to match, complete all as per specified and as directed by Engineer-in-charge. 47 M&L in-repair for second class hard wood plain fillets in square, rectangular or triangular in section, clean sawn, secured with nails or brads of sectional area exc. 6sqcm but not exc.13sqcm, complete all as specified and as directed by Engineer-in-charge. 48 S&F in-repair of exposed powder coated GI snap grid frame work (600x600 mm) for false ceiling comprising of wall/cleat angle of size 25x25x0.35mm and cross tee of size 24x38x0.70mm with suspended hangers of 2 mm dia. G.I. (upto 1200mm length) adjusting level fixed to any type of roof by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long with and including supplying & fixing/ laying/ inserting of pre-painted (white) 4mm thick designer classic E-boards (595x595 mm) to GI frame work, complete all as specified and as directed by Engineer-in-charge. 49 S&F of 0.50mm thick Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and as directed by Engineer-in-charge. 50 S&F of 0.50mm thick Pre-painted galvalume aluminum zinc coating GI based plain steel sheet of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and as directed by Engineer-in-charge. 51 M&L for preparing newly plastered surfaces of wall and applying two coats of distemper oil emulsion of any shade over a coat of chalk whitening and a coat of avg 1.00mm thick wall care putty including rubbing down the putty surfaces to obtained smooth finish, complete all as specified and as directed by Engineer-in-charge. 52 M&L for preparing newly plastered surfaces of wall and applying two coats of cement base paint of any shade over a coat of alkali-resistant priming paint, complete all as specified and as directed by Engineer-in-charge. 53 M&L for preparation of new or previously un-treated wooden Surfaces of any description n exc 10cm width or girth when unconnected with other painting or when painted in different tint and applying two coats of Synthetic enamel paint (1st quality) of any tint over a coat ofpink primer, complete all as specified and as directed by Engineer-in-charge. 54 M&L for preparation of new or previously un-treated steel/iron surfaces of any description, not otherwise described, over 10cm width or girth and applying two coats of Synthetic enamel paint (1st quality) of any tint over a coat ofred oxide primer, complete all as specified and as directed by Engineer-in-charge. 55 M&L for preparation of old painted steel/ iron surfaces of any description, not otherwise described, over 10cm width or girth and applying one coat of Synthetic enamel paint (1st quality) of any tint, complete all as specified and as directed by Engineer-in-charge. 56 M&L for Complete removal of existing treatment of wall and applying two coats of distemper oil emulsion of any shade over a coat of chalk whitening and a coat of avg 1.00mm thick wall care putty including rubbing down the putty surfaces to obtained smooth finish, complete all as specified and as directed by Engineer-in-charge. 57 M&L for Complete removal of existing treatment of wall and applying two coats of cement base paint of any shade over a coat of alkali-resistant priming paint, complete all as specified and as directed by Engineer-in-charge. 58 S&F of 600x450mmbevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers, complete all as specified and as directed by Engineer-in-charge. 59 M&L for point wiring with 1.5 sqmm size (nominal area) PVC insulated unsheathed single core multi stranded FRLSH copper conductor cable drawn into and incl consealed (on wall only) PVC conduit (medium grade) with fittings of adequate dia and length with all accessories and fittings like bends, elbow, crosses, etc. with PVC box of suitable size for mounting fittings like; switches, sockets, fan regulator, etc. incl 1.5 sqmm size PVC insulated multistranded FRLSH copper conductor cable as earth continuity conductor and connected to earth dolly for one light/ fan/ exhaust fan/ bell point controlled by one 1-way switch/ bell push including taking down the existing old unserviceable wiring connection with casing-capping/ conduit/ batten and switch board of any description with and including making good the disturbed surfaces (as/if requred),complete all as per specified and as directed by Engineer-in-Charge. 60 All as per Item No. 59 here-in-above, but for One 3 pin socket outlet, 5 Amps on the same board, complete all as specified and as directed by Engineer-in-charge. 61 All as per Item No. 59 here-in-above, but for One 3 pin socket outlet, 5 Amps, independent board, complete all as specified and as directed by Engineer-in-charge. 62 All as per Item No. 59 here-in-above, but for One 3 pin socket outlet, 15 Amps, independent board, with cables 4.0 sq. mm size, complete all as specified and as directed by Engineer-in-charge. 63 S&F of Switch piano, flush type single pole, One way 5/6 Amp, 220-240V, AC, complete all as specified and as directed by Engineer-in-charge. 64 S&F of Socket outlet 3/5 pin, 5/6A, flush type, 220-240V, AC, complete all as specified and as directed by Engineer-in-charge. 65 S&F of Switch socket combination 2 in 1, 3/5 pin, 15/16 Amp, flush type universal, 220-240V, AC, complete all as specified and as directed by Engineer-in-charge. 66 S&F of Switch socket combination 2 in 1, 3/5 pin, 5/6A flush type, 220-240V, AC, complete all as specified and as directed by Engineer-in-charge. 67 S&F of stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as reqd., 220-240V, AC, complete all as specified and as directed by Engineer-in-charge. 68 S&F of ceiling rose surface backelite three terminals, PVC/ polycarbonate, insulated body, complete all as specified and as directed by Engineer-in-charge. 69 S&F in-repair of Sub-main Wiring with 2-Runs of Single Core 6.0 Sq mm PVC insulated FRLSH multi-stranded 1100 Volts grade with Copper Conductor drawn through and including concealed (on wall only) PVC conduit (medium grade) ISI marked and its Accessories including 1-Run of Single Core 6.0 Sq mm PVC insulated FRLSH unsheated multi-stranded 1100 Volts grade with Copper Conductor Cable as Earth Continuty Conductor along with the Wiring and connected from DB to DB/Main Board, complete all as specified and as directed.NOTE :- (a)Cost of PVC conduit (medium grade) with all Fittings/Accessories will deem to be included in the quoted UNIT RATE.(b)Cables as mentioned in SCHEDULE ‘A’ Items and 1-Run of PVC conduit with all Fittings/ Accessories will be measured and paid as ONE UNIT.(c)Sub-main Wiring will be measured as length of PVC conduit only.Wire required for looping, etc as ordered will deem to be included in the quoted UNIT RATE. 70 S&F in-repair of Sub-main Wiring with 2-Runs of Single Core 4.0 Sq mm PVC insulated FRLSH multi-stranded 1100 Volts grade with Copper Conductor drawn through and including concealed (on wall only) PVC conduit (medium grade) ISI marked and its Accessories including 1-Run of Single Core 4.0 Sq mm PVC insulated FRLSH unsheated multi-stranded 1100 Volts grade with Copper Conductor Cable as Earth Continuty Conductor along with the Wiring and connected from DB to DB/Main Board, complete all as specified and as directed.NOTE :- (a)Cost of PVC conduit (medium grade) with all Fittings/Accessories will deem to be included in the quoted UNIT RATE.(b)Cables as mentioned in SCHEDULE ‘A’ Items and 1-Run of PVC conduit with all Fittings/ Accessories will be measured and paid as ONE UNIT.(c)Sub-main Wiring will be measured as length of PVC conduit only.Wire required for looping, etc as ordered will deem to be included in the quoted UNIT RATE. 71 S&F in-repair of Sheet Metal Enclosure MCB DB SPN, 8 way 240 volt, with rated Bus-bar, Double door type MCB DB suitable for mounting incoming and outgoingMCBs of any type, complete all as specified and as directed by Engineer-in-charge. 72 S&F in-repair of Sheet Metal Enclosure MCB DB SPN, 4 way 240 volt, with rated Bus-bar, Double door type MCB DB suitable for mounting incoming and outgoingMCBs of any type, complete all as specified and as directed by Engineer-in-charge. 73 S&F of MCB Single Pole & Neutral (SPN), C Curve, 40-63 Amps, 240 Volt for fixing on MCB DB’s, 10 KA, 50 Hz, conforming to IS/IEC 60898, connecting up and testing, complete all as specified and as directed by Engineer-in-charge. 74 S&F of MCB Single Pole (SP), C Curve, 6-32 Amps, 240 Volt for fixing on MCB DB’s, 10 KA, 50 Hz, conforming to IS/IEC 60898, connecting up and testing, complete all as specified and as directed by Engineer-in-charge. 75 S&F in-repair of surface and wall mounted LED tube light fitting (separate batten & rod will be measured as single unit) 1x 20W, (4 Feet) with aluminium housing & 6500K, 220-240 Volts, AC decorative with and including LED tube rod connecting up with three core flexible copper conductor cable of suitable size from ceiling rose to fitting, complete all as specified and as directed by Engineer-in-charge. 76 S&F in-repair of bracket suitable for LED Street light fitting/ house service bracket made out of 25mm bore (Dia) light grade GI pipe of 0.6m long, bend to required shape, including necesary clamps (Mild Steel Flat iron of 25x4mm) forfixing of building security/ street light fitting as per existing and painting the MS Flat iron with two coats of synthetic enamel paint, complete all as specified and as directed by Engineer-in- Charge. 77 S&F in-repair of energy saving new generation environmental friendly long life versatile presure die cast aluminium housing IP 66 building security light fitting luminaire with high power LEDs as light source and electronic driver of capacity 20 watts with pre wired and lens embedded PC cover having Bottom opening seperate driver compartment and Impact resistance of IK08 with necessary mounting arrangements, complete all as specified and as directed by Engineer-in-charge. 78 S&F in-repair of 1100 volts grade heavy duty cable PVC insulated aluminium stranded conductor of, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular of 16 Sqmm section, complete all as specified and as directed by engineer-in-charge. 79 M&L for earthing completewith galvanisedsteelearth plateelectrode of size 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below ground level, connected to galvanized earth wire 4.00 mm dia by means of bolts nuts check nuts & washers of galvanized iron or steel , procteded by GI pipe 15 mm bore( light grade)and watering pipe 20 mm bore GI pipe(medium grade) andchamber and coping shall be in PCC 1:3:6 type C1 using 20mm graded stone agg.50 mm thick cover of RCC 1:2:4 type B1 using 20 mm graded stone agg. reinforced with 8 mm dia MS tor bar @ 80 mm c/c both ways including excvation and earth work and removal of surplus soil complete all as shown in electrical plate no 3 of SSR PT 1, 1991 with charcoal dust and saltcomplete and earth leadconnected to earthing test point (up to main switches, DBs), including taking down the existing old damaged earthing, complete all as specified & testing on completion. NOTE:-(i)Item includes the cost of 1.5 mtr length GI pipe for protection for GI earth wire.(ii) item rates includes the cost of 7.5 mtr GI earth wire. 80 All as per Item No 79 here-in-above, but for 32x6mm earth strip procteded by GI pipe 40 mm bore( light grade), complete all as specified and as directed by engineer-in-charge. 81 Dismantling ACSR or AAC Conductors from the disturbed span including line spacer, etc., complete all as specified and as directed by Engineer-in-charge. 82 Dismantling Cross-Arms of Mild Steel Channel or Angle Sections, etc, including Mild Steel Bolts, Nuts, Washers, etc., complete all as specified and as directed by Engineer-in-charge. 83 Dismantling Insulators like Pin type, Shackle type from existing Street/ Security Light Pole of any description and any size, seggregating Seviceable Insulators and keep in safe custody for re-use, complete all as specified and as directed by Engineer-in-charge. 84 M& L for Excavation in trenches n.exc 1.5m wide and n.exc 1.5 m in depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes etc. and getting out in soft/loose soil complete all as per specified and as directed by Engineer-in-charge. 85 M&L for Returning,filling in, including spreading, leveling, watering and well ramming in layers n exc 25cm complete all as per specified and as directed by Engineer-in-charge. 86 M&L for Removing excavated material not exc. 50 m & depositing where directed at a level not exc. 1.5 m above starting point complete all as per specified and as directed by Engineer-in-charge. 87 M&L for Sand Cushioning (dry) in trenches/ducts for protection of UG Cables (below, above and around the UG Cable laid in Trenches) of 230mm Spread thickness (8 Cm in depth before laying the Cable and 15 Cm in depth after laying the Cable) and consolidated (punned) upto 180mm thickness, complete all as per specified and as directed by Engineer-in-charge.NOTE : For the purpose of Payment, Punned thickness of Sand Cushioning only will be measured and paid for. 88 Supply & Laying Fly ash Bricks, well burnt, laid breadth wise along the length of cable laid in trenches over sand cushion laid for UG cable protection, complete all as specified and as directed by Engineer-in-charge. 89 S&F of Galvanised Iron Pipe 40mm bore (dia) ‘light grade’ for protection of UG Cable, laid under Floors or Road Crossing, fixing to Pole with and including Mild Steel Clamps, Nuts, Bolts, etc., complete all as specified and as directed by Engineer-in-charge. 90 S&F of Galvanised Iron Pipe 50mm bore (dia) ‘light grade’ for protection of UG Cable, laid under Floors or Road Crossing, fixing to Pole with and including Mild Steel Clamps, Nuts, Bolts, etc., complete all as specified and as directed by Engineer-in-charge. 91 Supply & laying of LT XLPE insulated cable, sheathed, screened, PVC bedded, Galvanised Steel Strip or Wire armoured, Electic Power Cable (heavy duty) with Aluminium Conductor, 1100 Volts grade, cross-sectional area 50 Sqmm 3.5 Core, laid in Pipe/ Ducts/Trenches/ under Floor/ under Road/ fixing on pole/ above floor including Testing, complete all as specified and as directed by Engineer-in-charge. NOTE : Earthworks, Sand Cushioning, Bricks, GI Pipe, etc. will be measured and paid under appropriate Items. 92 All as per Item No. 91 here-in-above, but for cross-sectional area 16 Sqmm 4.0 Core, laid in Pipe/ Ducts/Trenches/ under Floor/ under Road/ fixing on pole/ above floor including Testing, complete all as specified and as directed by Engineer-in-charge. 93 All as per Item No. 91 here-in-above, but for cross-sectional area 10 Sqmm 4.0 Core, laid in Pipe/ Ducts/Trenches/ under Floor/ under Road/ fixing on pole/ above floor including Testing, complete all as specified and as directed by Engineer-in-charge. 94 All as per Item No. 91 here-in-above, but for cross-sectional area 10 Sqmm 2.0 Core, laid in Pipe/ Ducts/Trenches/ under Floor/ under Road/ fixing on pole/ above floor including Testing, complete all as specified and as directed by Engineer-in-charge. 95 Supply, installation, testing and commissioning of Factory made (CPRI Approved) floor mounted Outdoor cubical type LT Panel Board of size 1200 X 1000 X 600 MM fabricated out of 3.15 mm thick CRCA Sheet and angle iron 50 X 50 X 6 mm frame totally enclosed dust and vermin proof both side hinge opening arrangement on front and back, centre openable double door with locking arrangements, cable entry andexit from bottom with cable glands and gaskets, earth strip connections, Bus Bar chamber comprising 4 Nos copper strip bus bars air insulated and PVC sheathed capacity 200 Amps with colour coding mounted on DMC insulator and suitable for 200 Amps with main indication IA - 03 Nos (Make- L&T/ Siemens/ Schneider/ Legrand),Digital ammeter 0-500 Amps with selector switch (Make- L&T/ Siemens/ Schneider/ Legrand), digital voltmeter of 500Volts with selector switch (Make- L&T/ Siemens/ Schneider/ Legrand) and LED/ Neon type indicating lamps panel mounting type RYB-3 Nos (Make- L&T/ Siemens/ Schneider/ Legrand), internal wiring of suitable size to be used for incoming and outgoing connection of all switches/MCCBs & Bus-bar, including powder coat painting (RAL-7032) on the surfaces externally & internallyincluding necessary preparation of surfaces and providing PCC (1 : 3 : 6) type C-2 as in foundation all as specified and as directed, comprising of the following :-(a) Internal wiring with single core copper conductor cable/ PVC Insulated Copper Strip of suitable size incoming to bus bar and bus bar to outgoing MCCB/MCB-1Job.(b) Fine wiring with single core copper conductor cable for instruments/indicating lamps-1 Job. (c) Bus bar chamber comprising 04 Nos copper strip bus bar mounted on DMC ( Dough Moulding Compound) insulator and PVC sheathed of capacity 200 Amps with colour coding for RYB & N - 01 SetINCOMING(d)MCCB200 Amp, 4 Pole , 415 Volts rating with, overload, short circuitfault protection 3 phase with neutral link specially fixed incoming supply (Breaking capacity 35KA)Ics=100% of Icu, with Spreader terminal of both side-02 Nos. OUT GOING(e)MCCB100 Amp, 4 Pole , 415 Volts rating with, overload, short circuitfault protection 3 phase with neutral link specially fixed outgoing supply (Breaking capacity 25KA)Ics=100% of Icu, with Spreader terminal of both side-01 No.(f)MCCB63 Amp, 4 Pole , 415 Volts rating with, overload, short circuitfault protection 3 phase with neutral link specially fixed outgoing supply (Breaking capacity 25KA)Ics=100% of Icu, with Spreader terminal of both side-02 Nos.(g)MCCB40 Amp, 4 Pole , 415 Volts rating with, overload, short circuitfault protection 3 phase with neutral link specially fixed outgoing supply (Breaking capacity 16KA)Ics=100% of Icu, with Spreader terminal of both side-01 No.(h) MCB Triple Pole & Neutral (TPN) 10 Amp, 240 Volts rating specially fixed out going supply (Breaking capacity 10KA)-01 No. (Note-Fixing arrangement diagram and line diagram of the panel shall be got approved by accepting officer before panel fabrication). 96 Supply, installation, testing and commissioning of Factory made (CPRI Approved) floor mounted Outdoor cubical type LT Panel Board of size 900 X 700 X 450 MM fabricated out of 3.15 mm thick CRCA Sheet and angle iron 50 X 50 X 6 mm frame totally enclosed dust and vermin proof both side hinge opening arrangement on front and back, centre openable double door with locking arrangements, cable entry andexit from bottom with cable glands and gaskets, earth strip connections, Bus Bar chamber comprising 4 Nos copper strip bus bars air insulated and PVC sheathed capacity 200 Amps with colour coding mounted on DMC insulator and suitable for 200 Amps with main indication IA - 03 Nos (Make- L&T/ Siemens/ Schneider/ Legrand),Digital ammeter 0-500 Amps with selector switch (Make- L&T/ Siemens/ Schneider/ Legrand), digital voltmeter of 500Volts with selector switch (Make- L&T/ Siemens/ Schneider/ Legrand) and LED/ Neon type indicating lamps panel mounting type RYB-3 Nos (Make- L&T/ Siemens/ Schneider/ Legrand), internal wiring of suitable size to be used for incoming and outgoing connection of all switches/MCCBs & Bus-bar, including powder coat painting (RAL-7032) on the surfaces externally & internallyincluding necessary preparation of surfaces and providing PCC (1 : 3 : 6) type C-2 as in foundation all as specified and as directed, comprising of the following :-(a) Internal wiring with single core copper conductor cable/ PVC Insulated Copper Strip of suitable size incoming to bus bar and bus bar to outgoing MCCB/MCB-1Job.(b) Fine wiring with single core copper conductor cable for instruments/indicating lamps-1 Job. (c) Bus bar chamber comprising 04 Nos copper strip bus bar mounted on DMC ( Dough Moulding Compound) insulator and PVC sheathed of capacity 200 Amps with colour coding for RYB & N - 01 SetINCOMING(d)MCCB63 Amp, 4 Pole , 415 Volts rating with, overload, short circuitfault protection 3 phase with neutral link specially fixed incoming supply (Breaking capacity 25KA)Ics=100% of Icu, with Spreader terminal of both side-02 Nos. OUT GOING(e)MCCB40 Amp, 4 Pole , 415 Volts rating with, overload, short circuitfault protection 3 phase with neutral link specially fixed outgoing supply (Breaking capacity 16KA)Ics=100% of Icu, with Spreader terminal of both side-02 Nos.(f)MCB Triple Pole & Neutral (TPN) 10 Amp, 240 Volts rating specially fixed out going supply (Breaking capacity 10KA)-01 No.(g) Analog time switch, 415 Volts, 3 phase, 20Amps rating with connector -02 Nos. (Note-Fixing arrangement diagram and line diagram of the panel shall be got approved by accepting officer before panel fabrication). 97 M&L for taking down existing defective Street Light/Gate light/Post top/ Flood light Fitting of any Watt/Make from pole, repairing the same by opening Cover, re-wiring the Light Fitting with copper Conductor Cable of suitable size, cleaning and checking serviceability, testing and connecting up, complete all as specified and as directed. 98 Labour only for fixing Street Light/ Flood light Fitting of any Watt/Make in electric pole of any type, complete all as specified and as directed by Engineer-in-charge. 99 S&F of Energy saving new generation environmental friendly long life versatile presure die cast aluminium housing and heat resistant, IP 66 street light fitting luminaire with high power LEDs as light source and electronic driver of capacity 35/36 watts with pre wired and lens embedded PC cover having Top opening seperate driver compartment, with impact and corrosion resistant (IK-08) including thermal management in multiple optics and necessary mounting arrangements/ fixing bracket, complete all as specified and as directed by Engineer-in-charge. (NOTE- the cost of G.I. pipe bracket, bracket mounting clamp, bolts and nuts shall be paid separately) 100 All as per Item No. 99 here-in-above, but for 60 Watt LED street light, complete all as specified and as directed by Engineer-in-charge. 101 S&F in-repair of bracket suitable for LED Street light fitting/ house service bracket made out of 25mm bore (Dia) light grade GI pipe of 1.5m long, bend to required shape, including necesary clamps (Mild Steel Flat iron of 25x4mm) nut-bolts for fixing of building security/ street light fitting as per existing and painting the exposed MS portion with two coats of synthetic enamel paint, complete all as specified and as directed by Engineer-in- Charge. 102 Supply & Erecting in true vertical position of Steel Tubular Swaged Pole Type 410-SP-31 (9.00 Metre long) including Cast Iron Base Plate, Finial Taper Plug, Cap, Mild Steel Bolts, Nuts, Screws with and including applying two coats of Black Bituminous Paint Internally and Externally from bottom End of Pole upto PCC Coping and applying two Coats of Aluminium Painting over a coat ofRed oxidePrimer including necessary earthwork in excavation in any type of soil, removal of surplus soil to a distance of not exceeding 50.0m, Cement Concrete 1:3:6, type C-2 (40mm graded aggregate) as in Foundation of Poles filled upto ground level and Cement Concrete 1:2:4, Type B-1(20mm graded aggregate) as in Coping/Padestal of Poles and finishing the Concrete surfaces Fair and Even including necessary Formwork as required at Site(s), complete all as specified and as directed by Engineer-in-charge. NOTE: Earthwork, Cement Concrete, etc. will not be measured and paid separately. 103 M&L for Multistranded Copper Conductor flexible cable of3 Core 4 Sq mmsize drawn through steel tubular poles for interconnection of cable looping box to street light Fitting, Post Top Lantern &etc., complete all as specified and as directed by Engineer-in-charge. 104 S&F in-repair of Pole Box/Junction Box of size 155 X 210 X 92mm (LxBxH) made out of Polycarbonate material totally enclosed, dust and vermin proof, door pasted with rubber gasket, water tight IP 66/67 protection single leaf shutter in front having proper locking arrangements, mounted on security light pole with suitable clamps (GI Flat iron of 25x3mm), nuts, bolts, complete all as specified and directed by Engineer-in-charge.

Key Value

Document Fees
INR 500 /-
EMD
INR 98000.0 /-
Tender Value
INR 49 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Notice 0 KB
Click here to download tender document Tender Document 0 KB
Click here to download tender document Tender Document 0 KB
Click here to download tender document Tender Document 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail