}

Tender For Repairs/ Replacement And Day To Day Maintenance Of Gi/Di/Ppr Pipe Line Distribution System, Borewellstesting Of Water And Cleaning Of Oht & Ug Sump And Testing Of Water At Cdm Otm Areas, Dhruva At Cdm Area Under Age E/M No Iand Misclenious Repa, secunderabad-Telangana

Military Engineer Services has published Tender For Repairs/ Replacement And Day To Day Maintenance Of Gi/Di/Ppr Pipe Line Distribution System, Borewellstesting Of Water And Cleaning Of Oht & Ug Sump And Testing Of Water At Cdm Otm Areas, Dhruva At Cdm Area Under Age E/M No Iand Misclenious Repa. Submission Date for this Tender is 10-10-2024. clocks Tenders in secunderabad Telangana. Bidders can get complete Tender details and download the document.




Tender Notice

45231026
Corrigendum : Tender For Repairs/ Replacement And Day To Day Maintenance Of Gi/Di/Ppr Pipe Line Distribution System, Borewellstesting Of Water And Cleaning Of Oht & Ug Sump And Testing Of Water At Cdm Otm Areas, Dhruva At Cdm Area Under Age E/M No Iand Misclenious Repa
Open Tender
NCB
Telangana
Secunderabad
10-10-2024

Tender Details

REPAIRS/ REPLACEMENT AND DAY TO DAY MAINTENANCE OF GI/DI/PPR PIPE LINE DISTRIBUTION SYSTEM, BOREWELLSTESTING OF WATER AND CLEANING OF OHT & UG SUMP AND TESTING OF WATER AT CDM OTM AREAS, DHRUVA AT CDM AREA UNDER AGE E/M NO IAND MISCLENIOUS REPAIRS TO ELECTRIC SUPPLY SYSTEM, CAPACITOR PANEL, HIGH MAST, AMF PANEL AND ALLIED WORKS AT VARIOUS LOCATION OF AGE EM II OF GE (UTILITY) SEC’BAD- 1 M&L attending repair/rectification ofexternal water supply complaints of GI/CI/DI Pipe lines, sluice valves, gate valves of any type and size, no water supply and other water related complaints including transportation from complaint cell to complaint locations and back to complaint cell along with necessory T&P as required at site underCDM areas and the following type of complaints all as specified and directed. (Note :-Contractor should visit the site to understand site condition/distance between the complaint cell to the AOR before coating the rates. No claim in this regard will be entertained during execution stage). 2 Repairs and checking any type of leakages in GI/CI/DI/PP-R Pipe lines, sluice valves, gate valves of any type and size, no water supply and other water related complaints as directed. 3 All as per item No 1 here-in-before but for GI/PP-R pipe line of size20 mm dia to 40 mm bore. 4 All as per item No 1 here-in-beforebut for GI/CI/ PP-R pipe line of size 50 mm dia to 80 mm bore. 5 All as per item No 1 here-in-beforebut for GI/CI/PP-Rpipe line of size 90 mm dia to 150 mm bore. 6 All as per item No 1 here-in-before but for GI/CI/DI pipe line of size 200 mm dia to 300 mm bore. 7 M&L for attending break down of water supply pipe line at Military area / Military Roads /civil Roads /PWD Roads /Cantt board roadsand repair s to CI/DI/PPR/MSwater mains of size 80 mm to 400 mm bore at a given notice including necessary excavation in mud, in any type of soil , PCC,RCC, hard rock etcby manual or using special T&P such as JCB etc.De-watering from the trenches by using pump sets, rectification of leakages, fixing of CI specials such as collars, bends/tail peaces etc and making joints complete all as specified and as directed including making good of disturbed surfaces..Notes for Sl item No 1.01 to 1.06:-(a)The contractor will be alloted complaints at MES complaint cell on daily basis on all working days including Sundays and holidays and sufficient tradesman / resources will be deployed by him/her for completion of day to day comaplaints within 12 hours from the time of reporting. Any delay beyond above mentioned time limit without intimation of genuine cause, penalties will be recovered twice of the quoted rate for each un-attended complaint. (b)A detailed log book of complaints with completion/non-completion remarks from users/MES will be maintained by the contractor and the same will be updated on daily basis in consulatation with JE E&M/Engr-in-Charge. (c)The contractor will make suitable arrangment for emergency complaints and will notify authorised representive /Engr-in-Charge about extraordinary circumstances for probable non-completion or delay in rectification of complaints beyond stated time limit set for disposal of complaint.In case of any dispute the decision of accepting officer will be final and binding in this regard. 8 (d)The contractor will intimate MES authority well in advance if electric shutdown is required during rectification of complaints.(e)The quoted rate is deemed to be inclusive of transportation and other expenses required for the resource deployment at the complaint site around scattered Military station at Secunderabad.(f)The contractor will maintain location wise record of each spare/fittings utilized as per inventry format given by AGE E/M, Secunderabd and the same shall be submitted to E/M No Istore yard on daily basis.(g)The stationery required for the job work such as complaint slip books, gate pass book, job card and T&P shall be arranged and maintained by the contractor.(h) The cost of excavation / earth work and repairs to damaged roads, LT UG/HT cables, existing structure etc shall be deemed to be included in the quoted unit rate and no extra payment shall be allowed on this account.(j) Spares/GI fittings required to be replaced and shall be measured and paid separately under respective items. 9 Supply and Fixing of GI fittings 15mm bore, medium grade, ISI marked, smooth finished and make embosed on fittings complete all as specified and directed for the following fittings:- 10 Union 11 All equal Tee 12 Socket 13 Hex Nipple 14 Nipple 75mm Long 15 Nipple 100mm Long 16 Nipple 150mm Long 17 Elbow 18 All as per item No2 above but for 20mm bore. 19 Union 20 All equal Tee 21 Socket 22 Hex Nipple 23 Nipple 75mm Long 24 Nipple 100mm Long 25 Nipple 150mm Long 26 Nipple 200mm Long 27 Reducer 20mm x 15mm. 28 Elbow 29 All as per item No 2 here-in-before but for 25 mm bore. 30 Union 31 All equal Tee 32 Socket 33 Hex Nipple 34 Nipple 75mm Long 35 Nipple 100mm Long 36 Nipple 150mm Long 37 Nipple 200mm Long 38 Reducer 25mm x 15mm. 39 Reducer 25mm x 20mm. 40 Elbow 41 All as per item No2 here-in-before but for 40 mm bore. 42 Union 43 All equal Tee 44 Socket 45 Hex Nipple 46 Nipple 75mm Long 47 Nipple 100mm Long 48 Nipple 150mm Long 49 Nipple 200mm Long 50 Reducer 40mm x 25mm. 51 Reducer 40mm x 20mm. 52 Elbow 53 All as per item No2 here-in-before but for 50 mm bore. 54 Union 55 All equal Tee 56 Socket 57 Hex Nipple 58 Nipple 75mm Long 59 Nipple 100mm Long 60 Nipple 150mm Long 61 Nipple 200mm Long 62 Reducer 50mm x 20mm. 63 Reducer 50mm x 25mm. 64 Elbow 65 Taking up defective cast iron /GI water mains (including all fittings), with spigot and socket ends and lead joints including burning out joints and recovering lead from ground, cleaning the pipes free from sedimentation/scaling etc for reusing the serviceable pipes complete all as specified and directed for the following sizes:- 66 100mm bore. 67 150mm bore. 68 200mm bore. 69 Re-laying only cast iron /GI pipes obtained from in item No.7.00 above including laying level or to falls, in trenches, on the ground or on supports complete all as specified and directed for the following sizes:- 70 100mm bore. 71 150mm bore. 72 200mm bore. 73 Taking up or down GI/PVC/PP-R water tubing and connections including cleaning the pipes free from scaling for reusing the same in repairs / alteration or removable to store etc to water pipes and connections complete all as specified and directed for the following sizes:- 74 20 mm bore. 75 25 mm bore. 76 40 mm bore. 77 50 mm bore. 78 80 mm bore 79 Re-laying /refixing or reroutingof GI/PVC/PP-R old water tubing and connection in new or old position including fittings with old/new bends, elbows, socket nipples, tapers, and reducers etc as per site requirement (floors, walls and ceilings) complete all as specified and directed. 80 20 mm bore. 81 25 mm bore. 82 40 mm bore. 83 50 mm bore. 84 80 mm bore. 85 Supply, lay and fixing steel water tubes,medium grade, galvanised with all fitting laid in trenches/walls as in repairs complete all as specified and directed forfollowing bore of pipes :- 86 20 mm bore. 87 25 mm bore. 88 40 mm bore. 89 50 mm bore. 90 80 mm bore. Note :- Excavation and Earth work shall be measured saperately. 91 Supply and fix gun metal gate valve, ISI marked connected with iron wheel head, screwedat both ends for iron pipes and fixed including taking down of unserviceable gate valve complete all as specified and directed for the following sizes:- 92 20 mm bore. 93 25 mm bore. 94 40 mm bore. 95 50 mm bore. 96 M&L cutting of road / hard standing up to not exc 60 cm in width and60 cm depthfor laying of water pipe line complete all as specified and as directed. 97 Supply and fix 40mm dia Non Return Valve, ISI marked connected withscrewedat both ends for iron pipes and fixed including taking down of unserviceable NRVcomplete all as specified and directed :- 98 Supply and fix 50mm dia Non Return Valve, ISI marked connected withscrewedat both ends for iron pipes and fixed including taking down of unserviceable NRVcomplete all as specified and directed :- 99 Excavation in trenches not exc 1.5m wide and not exc 1.5m depth for laying of pipe lines, valve chambers, man holes for foundation of PCC/steel poles, laying cable tenches etc including forming bottom surface to required level and gradient and getting out in hard /dense soil complete all as specified and directed. 100 Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cms thick in soils complete all as specified and directed. 101 Removing excavated soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed. 102 S&F in replacementof DI D/F Gate valve (Soft Sealed) Resilient Seated Soft Sealing gate valves( Sluice valvesRAISING TYPE) with body bonnet of ductile cast ironof grade GGG-40/SG- 400/15 or GGG-50/SG-500/7 or equivalent grade as per IS 3896 - Part 2- 1985 and subsequent revisions, Wedge fully rubber lined with EPDM Food grade qualityand Seals of NBR and the valve should be vacuum tight and 100 % leak proof with face to face dimension as per BS 5163-89/IS 14846-2000/DIN 3202 F 4. andValves should be electrostatic powder coating both inside and outside pocket less body passage class PN 1.6 including all jointing materials (Gasket, Nut bolts etc)connecting and testing complete all as specified and directed. 103 80 mm bore. 104 100 mm bore. 105 150 mm bore. 106 200 mm bore. 107 M & L for dismantling of defective sluice valve for repairssuch as repacking stuffing box of sluice valve spindle, refacing, grinding, stuffing and threading of spindle, replacement of worn out check nut, repairs to gate assembly replacement of jointing materials such as rubber sheets, nuts, bolts & washers, gland rope in new one and refixing in its original position, testing on completion etc complete all as specified and directed of following sizes:- 108 80 mm bore. 109 100 mm bore. 110 150mm bore. 111 200mm bore. 112 250mm bore. 113 Burning out lead joints of the existing CI mains in position, including removing old lead carefully without demaging the pipe etc complete all as specified and as directed for the following sizes:- 114 80 mm bore. 115 100 mm bore. 116 150 mm bore. 117 200 mm bore.Note:- Exavation and earth work shall be measured and paid seperatelyunder the relevent Sch A item. 118 M&L for lead joint for CI/DI pipe includingspun yarn etc for spigot & socket pipes and fitiings complete all as specified and as directed for the following sizes:- 119 80 mm bore. 120 100 mm bore. 121 150 mm bore. 122 200 mm bore. 123 M&L Rubber Gasket joints (Tyton joints) including rubber ring suitable for spigot and socket CI/DI pipe and fittings complete all as specified and as directed for the following sizes:- 124 200mm bore. 125 150mm bore. 126 100mm bore.Note:- Excavation and earth work shall be measured and paid separately. 127 M&L for CI fittings for spigot and socket pipes such as bends (any type, radius and angle), tapers any type (straight, bend, increasing, decreasing or double socket etc), tee pieces, angle branch, cross (all sockets or socket & spigot collars, caps and plugs for joining up to 150 mm bore CI pipe as in repairs complete all as specified and directed. 128 M&L for Construction of brick masonry valve chamber of size 1000 x 1000 x 1000 mm (Internal dimenssions) with PCC foundation 1:4:8 type D2 using 40 mm graded stone aggregate 150 mm thick, 150 mm wide off sets allround over 100 mm thick hard core, brick masonry walls built in CM 1:6, 50 mm thick PCC 1:2:4 Type B1 coping finished even and smooth, rendering 10 mm thick in cement mortar (1:6) finished even and smooth, with out using extra cement internally and 150mm below GL externally and top of floor including excavation, earth work in hard/dense soil, 5 mm thick MS sheet cover fixed on 50 mm x 50 mm x 6 mm thick angle iron frame with hold fasts embedded in PCC coping with locking arrangement, mild steel handle and painting to steel surfaces with two coats of synthetic enamel paint over one coat of red oxide primer including disposal of surplus soil to a distance not exceeding 50 m etc complete all as specified and directed. 129 S&F Ductile iron pressure pipes 200 mm bore class K7, centrifugally cast with spigot and socket ends conforming to IS 8329/2000 with cement mortar lining inside the pipes and outside zinc coating suitable for push-on-joint (rubber gasket D jointing) inany length including DI specials as required at site confirming to IS 8329/2000 and all jointing materials and making good for disturbed surfaces of roads, path ways etc while laying the pipe line at site, site clearance for the route of pipe line, welding, cutting the existing CI/DI/MS pipe line of any size up to 150 mm bore for inserting branch connections etc complete including taking down old unserviceable CI pipes all as specified and directed. 130 All as per item No. 26 above but ductile iron pressure pipes 150 mm bore class K7, 131 All as per item No. 26 above but ductile iron pressure pipes 100 mm bore class K7, Notes for item No. 26 to28:- (a) DI pipe shall be laid in trenches at a depth of 0.7 to 1.0 m below the existing GL(b)Lead Joints / D-Joints will be measured and paid separately. (c) The contractor is responsible for obtaining the approval from Police Department for Traffic Diversion and related works if required in consultation with the MES deparatment.(d) Contractor is responsible for repair/replacement of any damages to the existing structures, Under Ground HT/LT/OFC Cables etc during the course of execution. 132 M&L ductile iron specials and fittings class K9 such as bends (any type, radius and angle) tapers any type, (straight, bend, increasing, decreasing or double socket etc) tee pieces, single branch. Y junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs suitable for DI pipes offlanged/socket ends of sizes 100mm bore to 300 mm bore as in repairs complete all as specified and directed . 133 Disconnecting the suction and delivery pipe line and electric connections of submersible pump set of 7.5 HP / 5 HP and removing it from its original position alongwith pipes and fittings carefully including chain pulley with tripod and transporting the same to the work shop (situated within the twin cities) for repair and refixing the same in its original position after repairs including connecting up of water and electric connections including testing andcommissioning complete all as specified.Note:- Expendable stores like cotton waste / cleaning materials, lubricants, gland packing, metal filling, machining and transportationfrom site to work shop and back are deemed to be included in rate quoted. ii) Labour element is included in unit rate quoted. 134 M&L for Lowering of submersible pump set of any capacity including all pipes and fittings complete with chain pulley and tripod after cleaning/repairing bymeans into openbore well and connecting electrical and water connections including testing on full load complete all as specified and directed. 135 M&L for rewinding ofthesubmersible motor with PVC insulated conductor with super enamelled copper conductor with ‘F’ class heavy grade insulation weight and turns to achieve its full efficiency inclduing tying the winding and connecting the coils and brining the connections as that of exisitng one including applying insulating varnish, heating and backing the windings thoroughly for submersible motor of above 5 HP and up to 7.5 HP capacity including taking down old unserviceable existing copper winding complete all as specified and directed. 136 All as per item No 32 above butfor thesubmersible motor above 3 HP and up to 5 HP capacity. 137 M&L disconnecting and removing the water and electric connections carefully from the existing submersible pump sets of capacity up to 7.5 HP for inspection, repairs and reassembling the pump and motor as per the original assembly after repairs / replacing the worn out unserviceable parts with new parts as ordered, including cleaning replacing the minor items like packing bolts, nuts, washers and MS clamps etc and applying one coat of approved hammertene spray paint on exposed steel surfaces, making the pump and motor fully serviceable including matching etc and testing the both after refixing and commissioning the pump set for satisfactory operatrion on its full loadcomplete all as specified and directed.Notes:- (a) The spares required for repair the pump sets will be measured and paid seperetely under respective item.(b) Expendable stores like cotton waste/cleaning materials, lubricants, gland packing, metal filling and transportation from site to work shop and back shall be deemed to be included in rate quoted.(c) Labour elements shall deemed to be included in unit rate. 138 Supply only the following spares for repairs of submersible pump set of 7.5 HP capacity complete all as specified and directed. 139 Motor bearing bush (LB) 140 Thurst bearing set 141 PVC Impeller 142 S.S Sleeves 143 Stage casing 144 Stage casing sleeves 145 Suction bush 146 Pump shaft 147 Pump coupling 148 Sand guard 149 Oil seal 150 Support plate MS with GInut bolt and washer 151 M&L disconnecting and removing the water and electric connections carefully from the existing submersible pump sets of capacity up to 5 HP for inspection, repairs and reassembling the pump and motor as per the original assembly after repairs / replacing the worn out unserviceable parts with new parts as ordered, including cleaning replacing the minor items like packing bolts, nuts, washers and MS clamps etc and applying one coat of approved hammertene spray paint on exposed steel surfaces, making the pump and motor fully serviceable including matching etc and testing the both after refixing and commissioning the pump set for satisfactory operatrion on its full loadcomplete all as specified and directed.Notes:- (a) The spares required for repair the pump setswill be measured and paid seperetely under respective item.(b) Expendable stores like cotton waste/cleaning materials, lubricants, gland packing, metal filling and transportation from site to work shop and back shall be deemed to be included in rate quoted.(c) Labour elements shall deemed to be included in unit rate. 152 Supply only the following spares for repairs of submersible pump set of 5 HP capacity:- 153 Motor bearing bush (LB) 154 Thurst bearing set 155 PVC Impeller 156 S.S Sleeves 157 Stage casing 158 Stage casing sleeves 159 Suction bush 160 Pump shaft 161 Pump coupling 162 Sand guard 163 Oil seal 164 Support plate MS with GInut bolt and washer 165 S&FMJ collar double ended flanged ISI embossed pressure 1.6 including jointing such as rubber gasket, nuts and bolts, washers materials etc complete including replacement of unserviceable sluice valves of any typecomplete all as specified and directed for the following sizes:- 166 80 mm bore. 167 100 mm bore. 168 150 mm bore. 169 200 mm bore. 170 300 mm bore 171 Opening Mono block pump set 5 HP capacity for inspection, repairs and reassembling the pump and motor as per the original assembly after repairs / replacing the worn out unserviceable parts with new parts as ordered including cleaning, replacing the minor items like packing bolts, nuts washers and MS clamps etc and applying one coat of approved hammertene spray paint on exposed steel surfaces, making the pump and motor fully serviceable including machining etc and testing the both after refixing and commissioning for satisfactory operatrion on its full load complete all as specified and directed. 172 Supply only the following spares for repairs of Mono block pump set upto 5 HP capacity:- 173 Ball bearing drive end 174 Ball bearing for non driving end 175 GM bush 176 CI impeller 177 MS pump shaft 178 Gland cover 179 Opening Mono block pump set 7.5 HP capacity for inspection, repairs and reassembling the pump and motor as per the original assembly after repairs / replacing the worn out unserviceable parts with new parts as ordered including cleaning, replacing the minor items like packing bolts, nuts washers and MS clamps etc and applying one coat of approved hammertene spray paint on exposed steel surfaces, making the pump and motor fully serviceable including machining etc and testing the both after refixing and commissioning for satisfactory operatrion on its full load complete all as specified and directed. 180 Supply only the following spares for repairs of Mono block pump set of 7.5/10 HP capacity:- 181 Ball bearing drive end 182 Ball bearing for non driving end 183 GM bush 184 CI impeller 185 MS pump shaft 186 Gland cover 187 S&F DOL starter 3 phase 415 Volts, 7.5 HP capacity rating 14 Amps, relay range 9 to 14 Amps, MK-1, including connecting up of incoming and outgoing connections and testing commissioning, including removingthe existing unserviceable one complete all as specified and directed. 188 S&F single phase preventor, SPPR type 360/380/415 volts suitable upto 7.5 HP pump including connecting up of wire / cable testing complete including removing the existing unserviceable one all as specified and directed.L&T Cat Part No CS81809OOOO orequivalent make in IndioAsian/Leagrand/ HPL. 189 S&F in repairs CI foot valve leather sheet type / flange type suitable for 80 mm dia GI suction heavy duty includung replacement of nuts, bolts washers, gaskets and flanges etc. complete all as directed and specified by Engr-in-charge. 190 Supply and lay submersible copper conductor cable 1100 volts grade PVC insulated, flexible, PVC sheathed with multistranded copper conductor of size 3 core 4 Sq mm cutting to required length connecting with necessary end ferrules / water proof joints including removing the existing unserviceable cable complete all as specified and directed 191 Supply and lay submersible copper conductor cable 1100 volts grade PVC insulated, flexible, PVC sheathed with multistranded copper conductor of size 3 core 6 Sq mm cutting to required length connecting with necessary end ferrules / water proof joints including removing the existing unserviceable cable complete all as specified and directed 192 Flushing/de-silting of accumulated soilfrom inside the borewell up to 250 mm dia and depth up to 150 meter by using air compressor/ special equipmentsof existing borewellsincluding surgingand flushing the bore at a pressure of 7 Kg / Sq cm complete with compressed air andflushing the sand, mud etc from the bore well till discharge of the fresh water, including testing of watersamples for chemical and bacteriological tests and yield testing for 4 hours complete all as specified and directed . Note: The rate shall be inclusive of hiring of Air compressor /special equipment, diesel, tools and Accessories including transportation and skilled man power to execute the work. 193 Supply & ReplacePVC pipe 6 kg/cm2of size 250 mm dia heavy duty screwed and socketed type to borewell confirming to IS complete all as specified and directed.Make : Sudhakar 194 M & L for GI pipe heavy grade 50mm dia, cut into 3.0 mtr length including providing of threading on both sides and lowering into the existing bore well along with existing GI pipe for increasing the length of the borewell pipe as in repairs complete all as specified and directed. 195 Supply & fixing HDPE heavy duty column pipe internal dia 50mm PN 16kq/Sqmm including necessary all fixings 196 M&L for removing submersible pump motor set of capacity up to 7.5 HP stuck inside the borewell of depth up to 100 meterbyflushingthe existing borewells of any size with drilling compressor mounted on truck at a pressure of 7 Kg / Sqcm with compressed air andflushing the sand, mud including flushing out tree roots etc from the bore well till removing of the stuck motor and then clear the bore by using Rod drilling using Bore well drilling machine from any kind of obstruction, reinstall the motor and coloumn pipe , necessary electric connection and testingcomplete all as specified and directed .Note : Rate quoted by the contractor is deemed to be inclusive of Flushing by using suitable compressor, rod drilling for clearing of bore well, Removingthe submersible pump set stuck inside the bore well and reinstall the same after repair including removing and refixing of coloumn pipe, electrical connections, testingetc as required. 197 Testing of borewell water from various location and submit the report to AGE E/M office. The vaious parameters studied are colour, taste, odour,Ph, turbidity,total dissolved solids, total suspended solids, total hardness , calcium hardness, magnesium hardness, copper ,iron,chlorides, sulphates, nitrates etc complete all as specified and directed 198 Reboreing/re-Drillingof existing borewell up to 250 mm dia, from the existing depth, at any type of strataby mud flash rotating equipment,from the Existingdepth to 100 Meters . Notes:- (i) Water injection charges if required (ii) Transport Charges , (iii) , Vehicle settlings & Flishing charges (iv)Expendable stores like cotton waste / cleaning materials, (v)Labour element. should beincluded in unit rate quoted. 199 100 Mtr to 200 Meters 200 M&L for cleaning of existing column pipes (3 Mtr length ) duly scraping, cleaning and painting complete through anti corrosive black bituminous paint all as per directed by engr-in-charge 201 Supply and replace heavy duty long socket suitable for 50 mm dia heavy duty GI pipe complete all as specified and directed 202 Design, fabrication, supply and errecting connecting and testing totally enclosed LT Cubical DOL starter panel board of size not less than 75cmx60xcmx30cm, 3 Phase 4 wire system indoor type 2mm ,double door front and back openeing type sloped canopy(Hood) on top extended , cable alley, provision of knock out type plates for various sizes of cable up to 25 Sqmm 4 Core in and out, CPRI approved factory made fabricated out of 2 mm thik CRCA sheet duly treated through 7 tank pre treatment process and painted with epoxy power coated mat finish of SIEMENTS GREY structral RAL 7032 shade colour, built in industrial type locking arrangement on front and back and pre wired with PVC insulated multi stranded copper conductor for controls ,Panel mounted on suitable size of angle iron frame thick duly painted & it shall be fixed from 45cm of ground level and embeded in PCC 1:3:6 type C1, 20cm below ground level and 15cm above ground level including taking down old unserviceable and consisting the following provisions:- 203 (a)MCB 6-40Amps, Triple Pole AC 415 Volts, 50Hz,10/16kA -01 No (selection of MCB rating with respect to pump set capacity).(b)3-ph,415volts, 50Hz,DOL starter suitable for pump set capacity above 7.5Hp to 10 Hp(as required) with suitablerelay , contactor, WithDryRun,Locked Rotor and Short Circuit protection Mobile ,Voltage and current based protection for all faults with individual protection enable/Disable features,inbuilt hour based and real time clock based timersAvailable in hindi,Gujarati,Marathi,Tamil,Telugu,Kannada,Inbuilt hour based and Real Time Clock based timers with time compensation feature With LineVoltage,PhaseCurrent,PowerFactor,Power,Malayalam,Bengali,Oriya,Punjabi and English languages with Energy metering and total run time information -01Nos(c)Single phase preventor (to-from prevent phase loss & phase failure)-01Nos(d)Indicator lamp set of 3 - 01 Set(e)Rotatory type selector Switch(f) Digital Type multi dislay volt Meter 0-500 Volts with selector switch (g)Digital type multi display meter 3 Ph Ampere meter 0-100 Amps with selector switch Make : MCB: L&T/Havells/Siemens, DOL starter: L&T/BCH, Single phase preventor: Minilec/GIC 204 Supply and fix Aviation obstruction light LED type SIMILER TO XGP400 IXLED-K2/RD 240 VOLT, incl fixing the lights with clamps, nuts,bolts etc complete all as specified and directed Note: Rate inclusive of fixing the light on the 22 mtr overhead tank. 205 Supply & lay heavy duty PVC insulated multi stranded copper conductor 3 core of size 2.5 Sqmm with 20 mm upvc conduit pipe 230 volts, 50 HZincl clamping of conduict on overhead tank of 22 mtr complete all as specified and directed. 206 Supply and fix 01 Mtr length, 15mmcopper Air termination rods lightning arrester is made out from Gun metal with 4 Spikes Incl nuts , bolts , pcc as required on site and taking down old unsv onecomplete all as specified and directed Rate inclusive of fixing the rod on the 22 mtr overhead tank. 207 Supply and fix galvanized earth strip 32 mm x 6 mm for earthing from earth plate to equipment incl insulators clamps etc complete all as specified and as directed.Rate inclusive of fixing the strip on the 22 mtr overhead tank. 208 M & L for maintenence free safe earthing electrode (SEE) designed pipe in pipe technology, set of 3 Nos earth pit duly inter connected with copper earth strip 25 mm x 3 mm, each earth pit having outer pipe of size76.3mm diaand inner pipe of size42.4 mm dia, each GI pipe have 2 mtrlongduly zinc and alloy coated having zinc coating (80-100) microns to whole length of pipe and alloy coating 250-300 micronto upper 300mm length of pipe, inside filled with crystal conductive compound (CCC) having anti corrosive and conductive properties to provide annular space of earth electrode and externalblack fill compound two bag of25 kg mixed with soil all arround the earth pipeforretainingmoisture, reduce the soil resistivity and dissipation of fault current, connected to earthing test point including excavation, earth work, PCC pit, RCC cover 50 mm thick, lifting rod 8mm dia, GI protection pipe 40 mm dia lightgrade for protection of inter connecting earthing strip from mechanical protection andtesting on completion, complete all as specified and directed. 209 M & L for maintenence free safe earthing electrode (SEE) designed pipe in pipe technology, Only 1 No earth pit duly connected with copper earth strip 25 mm x 3 mm, earth pit having outer pipe of size76.3mm diaand inner pipe of size42.4 mm dia, each GI pipe have 2mtrlongduly zinc and alloy coated having zinc coating (80-100) microns to whole length of pipe and alloy coating 250-300 micronto upper 300mm length of pipe, inside filled with crystal conductive compound (CCC) having anti corrosive and conductive properties to provide annular space of earth electrode and externalblack fill compound two bag of25 kg mixed with soil all arround the earth pipeforretainingmoisture, reduce the soil resistivity and dissipation of fault current, connected to earthing test point including excavation, earth work, PCC pit, RCC cover 50 mm thick, lifting rod 8mm dia, andtesting on completion, complete all as specified and directed. 210 Supply, install ,testing and commissioning ofChlorine Dosing System :- High Pressure single head adjustable chlorine dosing system including following accessories : Prepartion tankcapacity 100 ltrs. FRP dosing tankconsisting of water inlet line, outlet with Y strainer. Drain, Overflow,Conical bottom for sludge deposition, Pot hole with cover, Level gauge. Agitatorsingle flange mounted motor with plastic shaft and impeller and Service tank net capacity 100 ltrs. of FRP dosing tank consisting of water inlet line, Injector Dosing pup inlet arrangement, Drain, Overflow level gauge, inspection port. Agitatorflange mounted motor with plastic shaft and impeller. Provision of mounting lid and including drilling in existing CI/DI pipe of any dia including making necessary water and electricconnection including taking down old existingchlorine dosing system complete all as specified and directed .Note: Rate quoted by the contractor inclusive of all arrangement required for functioning of dising system including making hole on exixting CI/DI/MS/GI pipe line,connecting pipes/valves , necessary wiring and 15 Amps socket pointetc as required. 211 Supply only calcium Hypochlorite having 60%-70% available chlorine content in granular form (calcium based granular disinfectant) for water treatment (Drinking water and swimming pool) packed in 45 Kgs/50 kgseach drum complete all as specified and as directed. 212 Supply and fix 25mm Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule all as specified and directed 213 Supply and fix 20mm Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule all as specified and directed 214 M&L for cleaning of under mentioned RCC over head reservoir, under ground sump/semi under ground sump of any size and any height of staging by using mechanical means and scientific cleaning by carry out the following 7 stages of cleaning process for disinfection of surfaces:-(a) Cleaning of all external surfaces with hot water and Odor removal.(b) The inner surface of the walls and ceilings of the tank shall be cleaned with the pressure jet pump after dewatering in the tank.(c) After through cleaning of the tank, removal of algal calcination and other dust particles with high pressure including hot water treatment @50 degree centigrade.(d) Vacum cleaning and sludge shall be removed by using pump and the sludge has to be disposed off at a places as directed.(e) After removing the sludge from tank, the floor and inner surfaces of the tank shall be cleaned by using an industrial vaccum cleaner and the tank shall be made fully dust free and disinfection with bio-degradable chemical/anti bacterial spray and surfaces to be proven non toxic.(f) After the treatment as mentioned at (e) above, the inner surfaces of walls and ceiling shall be traeated with UV Radiation/Ozonization with UV rays.(g) After complete treatment is carried out, all inlet, over flow, delivery, wash out pipes, ladder and doors shall be painted with two coats of synthetic enamel black paint after thorough cleaning the surface and also the surfaces of sluice valves shall be painted with P.O. Red paint and writingcapacityof tank, date of cleaning and due date of cleaning on waqlls as specified and as directed.(h) The wire mesh of ventilaters of the tank shall be replaced with new GI wire mesh. 215 Over head tank of 100000 Gallons capacity at Dhruva Enclave. 216 Over head tank of 150000 Gallons capacity at Dhruva Enclave. 217 Semi under ground sump of 11000 Gallons capacity at CDM/OTM. 218 M & L for Water level indiactor, ISI marked suibale for 1.5/1.0 Lakh Gallon Over head water tank made out of MS sheet not less than 3.15 mm thick duly framed with Angle iron 50mmx50mmx5mm, painted withtwo coat synthetic enamelled white paint over a coat of red oxide primer, embossing /paste of water scale with red colour radium tapeincluding sutable fixing arrengement, wire rope, float , scale etc as in repairs complete all as specified and directed. 219 ELECTRIC SUPPLYM&L for attending, repair and rectification of external LT electric supply complaints on up to 1100Volts grade, over head/underground system alongwith necessary T&P, safety devices as per site requirement for the following type of complaints complete all as specified and directed:- 220 Replacement of worn out jumpers, jointing and tightening with new ACSR conductor.Note:- Single phase/two wire or 3 phase/4 wire system will be considered as one job for payment purpose. 221 Disconnecting from over head conductor, cutting worn out portion of LTcables of any type and size, carry out repairs including taking out cables from under ground loop line and rejoining the same to restore electric supply.Note :- (i) LT Jointing Kits, Cable protection Pipe if required at site will be measured and paid separately.(ii) Quoted rate is deemed to be inclusive of cutting and removing the pole coping and inserting the cable alongwith protection pipes. 222 Taking down old unsv Street light / flood lightfittings in any position of any capacity forRepair by replacement of unsv spares ( SPD / Driver / Mcpcb etc ) and re-fixing the same in existing location.Note:- Spares for repair of street light fittings will be measured and paid under respective items.Notes for Item Nos 1.01 to 1.04 :-(a)The contractor will be allotted complaints at MES complaint cell on daily basis on all working days and sufficient resources will be deployed by him/her for completion of day to day complaint within 24 Hrs from the time of reporting. Any delay beyond above mentioned time limit without intimation of sufficient cause, penalties will be recovered twice of the quoted rate for each un-attended complaint. (b)A detailed log of complaints with completion/non-completion remarks from users/MES will be maintained by the contractor and the same will be updated on daily basis in consultation with Engr-in-Charge or JE E&M as detailed.(c)The contractor will make suitable arrangement for emergency complaints and will notify auth rep/Engr-in-Charge about extraordinary circumstances for probable non-completion or delay in rectification of complaints beyond stated time limit set for disposal of complaint.In case of any dispute the decision of accepting officer will be final and binding in this regard.(d)The contractor will intimate MES authority well in advance if electric shutdown is required during rectification of complaints.(e)The quoted rate is deemed to be inclusive of transportation and other expenses required for the resource deployment at the complaint site around scattered Military station at Secunderabad.(f)The contractor will maintain location wise record of each spare utilized as per inventory format given by AGE E/M, Secunderabd and the same shall be submitted to E/M No II store on daily basis. 223 M&L for ACSR conductor, steel reinforced for LT over head lines on poles including streching tightining of poles insulator with binding wire of suitable size with insulator/streching of ACSR conductor including disconnecting/taking out old existing unsv ACSR conductors complete all as specified and directed. 224 Supply & Replace MCCB along with both side spreader link and nut bolts of appropriate size(Conforms to IEC:60947-II/IS:13947-II) in exisitng LT Panel box/Feeder Pillar boxes (KIOSK),in MCCB DBsof capacity 315-400 Amps, 4 Pole, 35 KA, 415 Volt including disconnecting/taking out existing old unsv/burned MCCB complete all as specified and directed. 225 All as per item No 73 here in before but of capacity 250 Amps, 4 pole, 25 KA 226 All as per item No 73 here in before but of capacity 200 Amps, 4 pole, 25 KA 227 All as per item No 73 here in before but of capacity 160 Amps, 4 pole, 16KA 228 All as per item No 73 here in before but of capacity 125 Amps, 4 pole, 16 KA 229 All as per item No 73 here in before but of capacity 100 Amps, 4 pole, 16 KA 230 S&F MCB, SPN 10-32 Amps, 415 Volts with breaking capacity 6KA, including disconnecting/taking out existing old unsv/burned Isolator complete all as specified and directed. 231 S&F MCB, TPN 10-32 Amps, 415 Volts with breaking capacity 6KA, including disconnecting/taking out existing old unsv/burned Isolator complete all as specified and directed. 232 S&F MCB, SP 10-32 Amps, 415 Volts with breaking capacity 6KA, including disconnecting/taking out existing old unsv/burned Isolator complete all as specified and directed. 233 Supply and fixing of automatic street light switch using infrared sensor based nature switch for automatic switching of street lights.Nature switch operation should bebased on natural light lux level. Required illuminance level for switching on is < 30 Lux and for switching off >10 lux. The sensor should also have part night operation facility of min 4 hrs to max 12 hrs.The sensor along with suitable power contactors incoming outgoing MCBS SP andand automanual (sensor bypass selection option should be enclosed in a pole /wall mountable enclosure made of rust proof electric shock proof termite proof and FR grade SMC Box conforming to IP54 single phase load of 8 KW with circuit wiringmin 10 sq mm copper wire 63 Ampscontactorans suitable MCBs atboth positions at incoming and out goings of breaking capacity 10 KA complete including necessary clamp (2 sets) / anchor bolt(4 nos)for fixing on pole / walllcomplete all as directed including taking down old one .Model no Swadeep-02 EC 8KW 1P or equivalent from Havells/Legrand . 234 Supply and fixing of automatic street light switch using infrared sensor based nature switch for automatic switching of street lights.Nature switch operation should bebased on natural light lux level. Required illuminance level for switching on is < 30 Lux and for switching off >10 lux. The sensor should also have part night operation facility of min 4 hrs to max 12 hrs.The sensor along with suitable power contactors incoming outgoing MCBS SP andand automanual (sensor bypass selection option should be enclosed in a pole /wall mountable enclosure made of rust proof electric shock proof termite proof and FR grade SMC Box conforming to IP54 three phase load of 12 KW with circuit wiringmin 10 sq mm, 3 nos contactor each of 40 - 50 amps, incoming outgoing MCB (3 nos) rating 40 amps of breaking capacity 10 KA complete including necessary clamp (2 sets) / anchor bolt(4 nos)for fixing on pole / walllcomplete all as directed including taking down old one Model no Swadeep-02 EC 12KW 3P or equivalent from Havells/Legrand . 235 Supply, lay, commissioning and testing of cable jointing Kit for 1100 V grade cable for outdoor End termination heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size16 to 50 Sqmm, complete all as specified and directed. 236 All as per item No 79 above but suitable foraluminium conductor cable of sizefrom 70 sqmm, 3.5 Coreto 95 Sqmm, 3.5 Core 237 All as per item No 79above but suitable foraluminium conductor cable of sizefrom 120 sqmm, 3.5 Coreto 150 Sqmm, 3.5 Core 238 All as per item No 79 above but suitable foraluminium conductor cable of sizefrom 185 sqmm, 3.5 Coreto 240 Sqmm, 3.5 Core 239 Supply and lay in trenches/fixed to walls/poles etc connecting buy using lugs, testingand commissioning XLPE insulated and PVC sheathed heavy duty LT 1100 Volts grade armoured under ground cable with stranded aluminium conductor 4 Core 10 Sqmm complete all, as specified and directed Note :- Earth work excavation, sand cushioning and brick protection shall be measured and paid separately. 240 All as per item No:80 above but 2 Core 10 Sqmm 241 All as per itemNo:80 above but 4.0 Core 25 Sqmm 242 All as per itemNo:80above but 3.5 Core 35 Sqmm 243 All as per item No:80 above but 3.5 Core 50 Sqmm 244 All as per itemNo:80 above but 3.5 Core 70 Sqmm 245 All as per itemNo:80 above but 3.5 Core 95 Sqmm 246 All as per itemNo:80 above but 3.5 Core 150 Sqmm 247 All as per itemNo:80 above but 3.5 Core 185 Sqmm 248 Taking out and Relaying of LT cable of size 10sq mm to 50 Sqmm 2/3.5 coreafter carrying out necessary Repair such as joining with Epoxy joint and laid with sand Cushioning and brick protection and making connection By using Lugsall as specified and directed by ingr in charge. Note: ( Earth work , sand Cushioning, brick protection, Lt Joints shall be measured and paid separately under Relevent Item) 249 Taking out and Relaying of LT cable of size 70 sq mm to 150 Sqmm 3.5 coreafter carrying out necessary Repair such as joining with Epoxy joint and laid with sand Cushioning and brick protection and making connection By using Lugsall as specified and directed by ingr in charge. Note: ( Earth work , sand Cushioning, brick protection, Lt Joints shall be measured and paid separately under Relevent Item) 250 Taking out and Relaying of LT cable of size 185 sq mm to 300Sqmm 3.5 coreafter carrying out necessary Repair such as joining with Epoxy joint and laid with sand Cushioning and brick protection and making connection By using Lugsall as specified and directed by ingr in charge. Note: ( Earth work , sand Cushioning, brick protection, Lt Joints shall be measured and paid separately under Relevent Item) 251 Supplying, erecting and fixing steel tubular swaged poles with cast iron base plate of size 300mm x 300mm x 6mm, finial taper plug, bolts, nuts & screws for type 410 SP-31 (9.0 mtrs long)including painting with two coats of aluminium paint over one coat of red oxide primer on all exposed surfaces and tarring with black bituminous paints to embedded portion in PCC and providing 3 Nos of 30cm wide circular bands with black & yellowpaint starting from plinth level at a gap of 30 cm in between 2 bands and numbering of poles, in yellow paint over black painted back ground at a height of 2m from bottom of pole with 5 cm large bold letters 2 (inch) wide including taking down old unserviceable PCC poles of any type complete all as specified and directed.Note: Excavation, earth work, PCC in foundation and coping shall be measured and paid separately under relevant item of this schedule. 252 Restreching/Restringing, tightening and repair to overhead line ACSR conductor of any size on LT poles including necessary Aluminium binding wire connectors PVC sleeves for jumper, fixing of insulators and prunning of tree complete all as specified and directed. Notes: (i) The distance between pole to pole in one span (contains 2/4/6 runs) i.e one span will only be considered for payment purpose. (ii) No Extra conductor will be measured for binding to insulators / jumpering etc. 253 Excavation in trenches, exc 1.5 mdepth but n.exc 3 mtr for foundation of PCC/Steel pole, laying of cable in trenches etc and getting out in Hard / Densesoil complete all as specified and directed. 254 Spreading riddled earth ( after preparation of excavated earth) inCable duct forcushioning of cable laid in trenches complete all as directed by Engineer-in-ChargeNote:- Punned thickness 18 CM( 6.25 Cm below cale and 11.75 cm above cale)will be measured for payment purpose. The earth removed during excavation to be used as rddled earth after crushing and sieving. Quoted rate inclusive of all arrangement as mentioned. 255 Supply and Laying bricks, common burnt clay building bricks, sub class B of size 210 x 110 x 70 mm laid across in trenches for cable protection complete all as specified and directed. 256 Laying only old Brick in trenches for Under Ground Cable Protection (Serviceable Materials obtained from Item here-in-before), complete all as directed. 257 Supplying and laying reinforced precast concrete cable cover class LV , Type 1 flat with size 250mmx150 mm x 40mm all asspecified and directed by Engr-in-Charge. 258 M&L PCC 1:4:8 type D2 using 40 mm graded stone aggregate for filling & foundation of pole & mass complete all as directed 259 M&L PCC 1:3:6 type C2 using 40 mm graded stone aggregate for filling & foundation of pole & stay complete all as directed 260 M&L PCC 1:2:4 type B1 using 20 mm graded stone aggregate for coping of pole complete all as directed 261 Cutting the existing road/PCC surface straight by manual, depth and width not less than 1 mtr below ground level for passing of underground cable and filling back with excavated soil upto 75% road portion and 25% shall be made with cement concrete 1:2:4 (using 20 mm graded aggregate stone complete all as specified and directed. 262 M&L for road crossing/drain crossing by adopting trench less tunneling work through specified pipe jacking method by erecting the equipment to true to the allignment and gradient by haidrolic pipe jacking technique complete including tunneling, excavation in any type of soils including hard rock, HDPE / GIpipe medium dutyduty of size 100 mm diain any length including jointing materials to carry LT UG cables of size upto 240 Sqmm and necessary conveyance charges of machinery and other required materials in co-ordination with the concerned authorites complete all as specified and as directed.nOTE ; PIPE WILL BE MEASURED AND PAID SEPARATELY UNDER RELIVENT ITEMS 263 M&L for replacement of broken earth pit made out of PCC 1:2:4 type B1 using 20 mm graded crushed stone aggregate, 20 mm thick and earth pit cover made out of RCC 1:2:4 type B1, cover reinforced with 8 mm dia MS deformed bars @ 100 mm centre to centre both ways with hook made out of 8 mm dia bar, watering arrangement with funnel and wire mesh and including reconnecting of earth lead of any type with new nuts, bolts and washers etc as required at site complete all as specified and directed. 264 M&L for painting the existing LT steel poles of 9.0 Mtr long including cross arms, clamps, street light junction boxes etc with 1 coats of aluminium paintincluding throughly cleaning the existing surface, writing of pole numbers in yellow circle 15 cm with black paint on poles. Painting the poles up to 1.5 Mtr height with alternate bands 30 cm height (3 Nos black and 2 Nos Yellow) from ground level, complete all as specified and directed. 265 M&L for Painting the existing LT PCCpoles with 1 coats of synthetic enamole base paintincluding painting of cross arms, clamps, etc with one coat of aluminium paint and providing alternative band of 30 cm width (3 black and 2 yellow) from bottom of pole to 1.5 metres height , writing of pole numbers in yellow circle15 cm with black paint on poles complete all as specified and directed. 266 Advance Maintenance Free G.I. SAFE EARTHINGElectrodewith PIPEof not less than 50 mm outer dia) and two meterlength, The electrode should be ofgalvinised (80 -100 micron) along with earth lead as Galvanised steel strip of size 32 X6 mm7.5 m . The GI Electrode shall be pre-filled with Cristaline Conductive Material (CCM) . The GI electrode shall be surrounded with 25 kg BackFill compoundto provide maximum contact between the electrode and Back Fill Compound. The earting pitcover should be factorty built (sizeTOP- 10 Inch, Bottom -13 Inch, Height 10.25 Inch ) made of heavy duty Polypropylenecomplete all as specified and directedmakeASHLOK/INDELEC/JMV /TERCEL/TRUE POWER 267 Trimming/pruning and removing of tree branches or any other foreign objects from HT/LT over head conductor and clearing the OH Line of any type and size for one span of any length in 2 way /4 way/6 way conductor system. Notes: (i) Insulators of any type, connectors and ACSR conductor of any size required at site will be measured and paid separately under relevant item of this schedule. (ii) The contractor is responsible for provision of Necessary T & P and safety equipments to complete the job. 268 Cutting unaxious green growth and grass by manual labour or by machine at all 11 KV Electric Installation premisses/around 2/4 Pole structure/along the boundary fencing and removing rubbish from the site of work complete all as specified and directed. 269 S&F LED street light fitting 90 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete, lighting source and lens embedded PC cover having TOP OPENING seperate driver compartment with IP66 protection and impact resistance of IK07 with 10 KVBuilt-in-Surge Protection Device,road way light fitting with high power LED as light source of capacity 90 watts with suitable drivers etc and connecting with 1.5 Sqmm copperconductor PVC insulated three core weather proof cable etc, fixing to wall/pole, complete all as specified and directed. Note :(i) LEDs used should be the make of Cree/Osram/Lumilieds/Nitchia.(ii) Contractor has to produce LM-79/LM-80 certificate alongwith purchase vouchers.(iii) Surge protection of the drive should be 10 KV 270 All as per item No 102 above but 100 watts.Make :Bajaj / Havells /SURYA / Wipro/crompton/philips/halonix/luker. 271 All as per item No 102 above but 120 watts.Make :Bajaj / Havells /SURYA / Wipro/crompton/philips/halonix/luker. 272 All as per item No 104 above but 150 watts.Make :Bajaj / Havells /SURYA / Wipro/crompton/philips/halonix/luker. 273 All as per item No-102 above but 200 watts.Make :Bajaj / Havells /SURYA / Wipro/crompton/philips/halonix/luker. 274 S&F LED flood light 100 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrossion resistant complete with driver and lamp die-cast aluminium IP66 flood light, suitable for highlighting architectural facade and general purpose lighting, with high power LED as light source of capacity 120 watts with suitable drivers etc and connecting with 4.0 Sqmm aluminium conductor PVC insulated twin core weather proof cable etc, fixing to wall/pole complete all as specified and directed.Make :Bajaj / Havells /SURYA / Wipro/crompton/philips/halonix/luker.Note :(i) LEDs used should be the make of Cree/asram/Lumilieds/widchia (ii) Contractor has to produce LM-79/LM-80 certificate alonwith purchase vouchers and Guarantee certificate from Manufacturer. (iii) Surge protection of the driver should be 10 KV 275 All as per item No 103 above but 120 watts. 276 All as per item No 103 above but 150 watts. 277 All as per item No 103 above but 200 watts. 278 Supply, fixing, connecting and testingpost top light fitting in spherical shape polycarbonate PMMA clear diffuser and IP65 protection, new generation energy saving and environmental friendly long life aesthetically desinged aluminium decorative luminaires with high power LED as light source of capacity1X35/40 watts, fixed to Pole/Wall in any position including taking down old existing street light fitting of any type and capacity complete all as specified and directed. 279 Supply only LED Driver of similer wattage with operating voltage inputac 85- 300 volt , pf> .95 asper IS 15885 with inbuilt surge protectionof minimum 5 kvand BIS crtifiedsuitable for60 watts LEDstreet light fittings of any makecomplete all as specified and directed. 280 Supply only LED Driver of similer wattage with operating voltage inputac 85- 300 volt , pf> .95 asper IS 15885 with inbuilt surge protectionof minimum 5 kvand BIS crtifiedsuitable for70/72 watts LEDstreet light fittings of any makecomplete all as specified and directed. 281 Supply only LED Driver of similer wattage with operating voltage inputac 85- 300 volt , pf> .95 asper IS 15885 with inbuilt surge protectionof minimum 5 kvand BIS crtifiedsuitable for90 watts LEDstreet light fittings of any makecomplete all as specified and directed. 282 Supply only LED Driver of similer wattage with operating voltage inputac 85- 300 volt , pf> .95 asper IS 15885 with inbuilt surge protectionof minimum 5 kvand BIS crtifiedsuitable for100/110/120 watts LEDstreet light fittings of any makecomplete all as specified and directed. 283 Supply only LED Driver of similer wattage with operating voltage inputac 85- 300 volt , pf> .95 asper IS 15885 with inbuilt surge protectionof minimum 5 kvand BIS crtifiedsuitable for100 watts LED floodlight fittings of any makecomplete all as specified and directed. 284 Supply only LED Driver of similer wattage with operating voltage inputac 85- 300 volt , pf> .95 asper IS 15885 with inbuilt surge protectionof minimum 5 kvand BIS crtifiedsuitable for120 watts LED floodlight fittings of any makecomplete all as specified and directed. 285 Supply only LED Driver of similer wattage with operating voltage inputac 85- 300 volt , pf> .95 asper IS 15885 with inbuilt surge protectionof minimum 5 kvand BIS crtifiedsuitable for150 watts LED floodlight fittings of any makecomplete all as specified and directed. 286 Supply only LED Driver of similer wattage with operating voltage inputac 85- 300 volt , pf> .95 asper IS 15885 with inbuilt surge protectionof minimum 5 kvand BIS crtifiedsuitable for200 watts LED floodlight fittings of any makecomplete all as specified and directed. 287 Supply and fixingsteel light bracket made out of 40 mm bore mild steel GI light grade tubing over all length 1.5 mtr bend to shape as directed including providing two Nos MS flat iron 40x6 mm clamp of appropriate size with nut bolts and washer duly painted with two coat of synthetic enamel paint over a coat of primer (GI surface shall not be painted) complete all as specified. 288 S&F PVC insulated unsheathed/sheathed cable with stranded Aluminium conductor 1100 Volts grade, flat twin core service cable of size 4 Sqmm conforming to IS:694/1990 with latest amendments ISI including disconnecting/taking out existing unsv/damaged old service cable complete all as specified and directed. 289 All as per item No 114 above but of size 6 Sqmm complete all as specified and directed. 290 All as per item No 114 above but of size 10 Sqmm complete all as specified and directed. 291 S&F hot press moulded SMC junction/terminal box of size with internal diamensions of 300 x 200 x 1055 mm with hinged door, incl provision of 2 way connector 415 Volts made out of polycarbonate or bakelite and 1 No MCB of 6 Amps with DIN bar, drilling holes for cable connections, connecting incoming and or out going cables by providing suitable of size of cable lugs/glands, fixed on pole by means of clamps made out of MS flat iron of size 25mm x 3 mm 2 Setincluding dismantling of old unserviceable all as specified and as directed. 292 Supply and laying GI tubing light grade of size 40 mm for cable protection on road/drain/floor/pole including necessary clamps 40x4mm. 293 Supply and laying GI tubing light grade of size 50 mm for cable protection on road/drain/floor/pole including necessary clamps 40x4mm. 294 Supply and laying GI tubing light grade of size 80 mm for cable protection on road/drain/floor/pole including necessary clamps 40x4mm. 295 Supply only of aluminium cable lugs of following sizes :- 296 16to 25 Sqmm Size 297 35to 50 Sqmm Size 298 70to 95 Sqmm Size 299 120to 150 Sqmm Size 300 185to 240 Sqmm Size. 301 S&FMCCBboxFACTORY FABRICATED Powder coated Suitable for fixing at WALLincluding two set of clampscomprisinf with the following i) MCCB100 Amps 16 KA FP WITH BOTH SIDE SPREADER LINK. 302 Supply and fixon wall with necessary arrangements busbar chamber 100 amps 4 way4 polewall mounted IP -31 , made out of 1.6 mmthick CRCA sheet epoxy powdwer coated single layer operational voltage 440 Volt , Short circuit current capacity 25 KA for 1 Secondincluding necessary cable connectionscompleteall as specified and directed.Note: Quoted rates inclusive of necessary fixing arrangement and cable connections , cable glands as required for proper fixing / functioning of Bus Bar Chamber. 303 Supply and fixon wall with necessary arrangements busbar chamber 200 amps 4 way4 polewall mounted IP -31 , made out of 1.6 mmthick CRCA sheet epoxy powdwer coated single layer operational voltage 440 Volt , Short circuit current capacity 25 KA for 1 Secondincluding necessary cable connectionscompleteall as specified and directed.Note: Quoted rates inclusive of necessary fixing arrangement and cable connections , cable glands as required for proper fixing / functioning of Bus Bar Chamber. 304 Dismentling ofdamage / broken coping of PCC/steel pole of any size anf and removing the debries from site complete all as specified and directed 305 Supply and fixing lantren of dia 60 CMfor fixing of flood light,cap type to be fixed on the top of 9 m SP-31 / 11 m SP-55Steel pole , made of MS pip medium gradedia greater than the top dia of the pole of length 0.35 M supported by MS flat iron of size 50X6 mm 8 nosincluding two coat of aliminium painting over a coat of redoxide primer complete all as directed 306 Dismantling LT steel tubuler pole of any height by taking out from PCC foundation complete and shifting to other location as directed including fixing the pole in true vertical position including excavation and earth work, PCC 1:4:8 type D2 (using 40mm graded stone aggregate) as base concrete and PCC 1:3:6 type C2 (using 20mm graded stone aggregate) in both foundation and coping of poles all as specified in SSR Part I-2009 and applying two coats of aluminium paint to pole surface complete all as directed by Engineer-in-Charge. 307 Supply anfd fix locally availablegate / gurden lightlight best qualitymetal Silver / metal blackDecorative Exterior of size not less than 300 mm X220 mm with and including LED bulb 9 wattsuitable for outdoor installationandsuitable for fixing in 40/50 mm dia GI pipe including necessary connections complete all as specified and directedincluding taking down old one . 308 Supply anfd fix locally availablegate / gurden lightlight best quality Black Color Steel Shade With Fiber Glass Outdoor Gate Lampof size not less than 360 mm X250 mm with and including LED bulb 9 wattsuitable for outdoor installationandsuitable for fixing in 40/50 mm dia GI pipe including necessary connections complete all as specified and directedincluding taking down old one . 309 Material and labour for Taking down UNSV LED Lights and removing Carbon from its connector joints incl replacement of Connecting wire with new PVC sheated weatherproof 3Xsingle core cable for electrical connection and refixing the fittingafter repair to its original/New location or as directed by engr-in-charge.(connecting wire will be measured and paid separately only) 310 S&F LED High Bay light 90 W lumanaries with with high luminous efficacy,IP 65 protected, front toughened glass with discrete high lumen LED along with Reflector including dismantling of old unserviceable fitting all accessories complete all as directed. 311 Supply anfd fix locally available Acrylic glob light best quality clear with and including LED bulb 9 watt of 200 mm dia complete suitable for fixing in 40/50 mm dia GI pipe including necessary connections complete all as specified and directed including taking down old one . 312 Supply anfd fix locally available Acrylic glob light best quality clear with and including LED bulb 9 watt of 300 mm dia complete suitable for fixing in 40/50 mm dia GI pipe including necessary connections complete all as specified and directedincluding taking down old one . 313 Material and Labour for drawing two runs ofPVC insulated unsheathed single core multi stranded copper conductor FRLS cable of size 1.50 sq mm with one run of PVC insulated unsheathed single core multi stranded copper conductor FRLS cable of size 1.50 sq mm including 20mm dia PVC conduitof dia 20 mm medium gradeexclusive of boxes but inclusive of all tees, bends, elbow, reducers etc and fixing accessories such as couples, lock nuts, saddles, pipe hooks, clampsetc complete all as specified 314 M&L for Servicing ofACB Breaker indoor/outdoor type of any make/model/capacity, checking of switching ON/OFF& tripping system, Spring charge Motor working system,checking of all electrical mechanical components of AMF panel and Setting the same for proper working of Breaker, testing of operation manually and auto mode complete all as directed by Engr-in-charge. Note:-All the mechanical parts are thoroughly cleaned by suitable cleaning agent & moving parts are properly lubricated 315 Supply&Fixing heavy duty box type capacitors 5kVAR in existing panel including including necessary wiring & misc accessroies for satisfactory completion of job taking down old unserviceable one complete all as directed by Engineer-in-Charge. 316 Supply&Fixing heavy duty box type capacitors 10kVAR in existing panel including including necessary wiring & misc accessroies for satisfactory completion of job taking down old unserviceable one complete all as directed by Engineer-in-Charge. 317 Supply&Fixing ofcapacitor duty contactor suitable for capacitor rating 5 kVAR ,50Hz,440v,3-ph,3-pole in existing panel including including necessary wiring & misc accessroies for satisfactory completion of job taking down old unserviceable one complete all as directed by Engineer-in-Charge. 318 Supply&Fixing ofcapacitor duty contactor suitable for capacitor rating 10 kVAR ,50Hz,440v,3-ph,3-pole in existing panel including including necessary wiring & misc accessroies for satisfactory completion of job taking down old unserviceable one complete all as directed by Engineer-in-Charge. 319 Supply&Fixing of Auto/Manual selector swtich in existing panel including including necessary wiring & misc accessroies for satisfactory completion of job taking down old unserviceable one complete all as directed by Engineer-in-Charge. 320 Supply, Installation, test and Commissioning suitable size factoryfabricated, out door type,LT FEEDER PILLAR BOX made out of 3.15 mm thick CRCA Sheet of suitable size with projected Globe roof for rain water protection Dust and Vermin Proof ,Double door withboth side opening including Neoprene Rubber Gasket,, suitable for 440 Volt 3 Phase 4 Wire System ,including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate comp-lete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and embededwith 50X50X6mm Mild Steel Angle Iron Frame and 600 mm above the Normal Ground Level comp -lete withinternal connection with suitable size of cable ,cable lugs,and cable glandsPCC Foundation in Cement Concrete 1:3:6 (20mm Graded Stone Aggregate) and Test-ing after Installation complete all as specified and comprising of the following :–(a) Aluminium bas bar 200amps - 04 Nos, supported with suitable size of heavy duty porcelin stand lock with suitable sizeof brass nut, bolts and washer with heat shrinkable PVC sleeving.The bar shall be colour coded (red, yellow and blue) for three phases and black for neutral.b) MCCB 100amps ,415 volt ,16 KA Breaking capacity4 pole Electromagnetic releaseduly connected to Bus Bar AsIN COMING- 01 NosMake Legrand model no: 420015/ Equivalent from Schinder/L&T/Hagar

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 03-10-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 10-10-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 90000.0 /-
Tender Value
INR 45 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail