Tender For Electrification Work And Supply, installation, testing & commissioning Of Plant And Machinery Or Its Related Work Including 5 Year Operation And Maintenance In 03 Nos. 100 Mt Cold Room And 04 Nos. 10 Mt Ripening Chamber Etc. At Nmy Sitapur Road, Lucknow, 1 Wiring point for light with 1.5 sq. mm. FRLSH PVC insulated multistrand single core copper conductor cable in pvc conduit pipe partly concealed in the wall and partly laid in slab along with the reinforcement before concreting, complete with 14 SWG copper earth continuity wire, piano type switch & ceiling rose/angle/batten holder on 3 mm thick phenolic peminated backlight sheet etccomplete in all respect as directed including matching colour wash, but in PVC conduit with 1.5 sq. mm FRLSH PVC insulated multistrand copper conductor cable as earthwire down inside conduit. 2 Wiring point for fan/fresh air fan (light duty exhaust fan) with 1.5 sq. mm. FRLSH PVC insulated multistrand single core copper conductor cable in heavy gauge rigid steel conduit pipe partly concealed in the wall and partly laid in slab along with the reinforcement before concreting, complete with 14 SWG copper earth continuity wire, piano type switch & ceiling rose/angle/batten holder on 3 mm thick phenolic peminated backlight sheet etccomplete in all respect as directed including matching colour wash,but in PVC conduit with 1.5 sq. mm FRLSH PVC insulated multistrand copper conductor cable as earthwire down inside conduit. 3 Add for light/fan points with modular type switch in place of piano type switch 4 Supply and wiring of submain with two nos. 4 sq. mm. FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 20 mm dia heavy duty (2 mm thick) PVC conduit with one No. 2.5 sq. mm. FRLSH PVC insulated multistrand coper conductor cable earth contuiity wire drawn in conduit. 5 Supply and wiring of 3 numbers 4 sq. mm. FRLSH PVC insulated multistrand single core copper conductor cable in 25 mm dia heavy duty (2mm thick) PVC conduit with 2 nos 2.5 sq. mm. FRLSH PVC insulated multistrand copper conductor cable as earth continuity wire down in conduit. 6 Supply and fixing of electronic fan regulator (Modular) 300/400 watt, ISI marked, on the existing switch board including making connections, required material, labour T&P etc. for proper completion of work to the satisfaction of Engineer in charge of work 7 Wiring point for plug with 1.5 sq. mm. FRLSH PVC insulated multistrand single core copper conductor cable in PVC conduit conduit partly concealed in wall and partly laid in slab alongwith the reinforcement before concreting, complete with 14 SWG copper earth continuity wire and piano type switch and socket etc., complete in all respect including matching colour wash 8 Supply and fixing of 16 SWG M.S. drum duly painted including making whole in wall for exhaust fan and finishing properly complete in all respect 9 S & F Surface/Flush mounting 12 ways TPN distribution board without additional matel door without MCB complete in all respect as directed at site by Engineer in charge CAT-A 10 S & F Surface/Flush mounting 8 ways SPN distribution board without additional matel door without MCB complete in all respect as directed at site by Engineer in charge CAT-A 11 S & F Single pole MCB blinking plateCAT-B 12 S & F 6 to 32 Amp. MCB (10 KA) C Curve CAT-A 13 S & F 40 Amp. DP MCB (10 KA) C Curve CAT-A 14 S & F 63 Amp. 4 pole MCB (10 KA) C Curve CAT-A 15 As in no. 1302 (B) but in 20mm dia heavy duty (2mm thick) PVC conduit with 2 number 1.5 sq. mm. FRLSH PVC insulated 1100 V grade multistrand single core coper conductor cable as earthing continuity wire drawn inside the conduit. 16 Supply and fixing of power plug with 20 Amp./250 volts flush type modular and 5 pin 20 A/250 volts flush type universal modular socket on cancealed M.S box including supply of all material, labour T&P etc. required for proper completion of work. 17 Supply and burying of 600 mm x 600 mm x 6mm G.I. plate vertically for earthing with its top at least 3 mtrs below gound lavel complete with 20 mm dia and funnel for watering and one earthing lead of one no. 8 to 10 SWG G.I. wire in 15 mm dia G.I. pipe up to appron (and from appron to switch board the cost of G.I wire and pipe will be extra) upto switch board, 30 cm square C.I box with hinged cover masonry encloser funnel at top, alternate layers of charcole/coke and salt at 150 mm thick alround etc, as per direction of engineer incharge complete in all respect as per drawing 18 Supply and burying of 600 mm x 600 mm x 3mm copper plate vertically for earthing with its top at least 3 mtrs below gound lavel complete with 20 mm dia and funnel for watering and two earthing lead of two no. 8 to 10SWG G.I. wire in 15 mm dia G.I. pipe up to appron (from appron to switch board the cost of G.I wire and pipe will be extra) upto switch board, 30 cm C.I frame with hinged cover masonry housing alternate layers of charcole/coke and salt at 150 mm thick alround etc,complete in all respect 19 Supply and laying of 32 mm x 6 mm G.I. strip from earth electrode directly in the ground complete in all respect 20 Supply & fixing of vertical air termination final rod comprising of 300mm long X 25mm dia GI rod with one pointed prong and 100dia X 3 mm thick base plate complete in all respects. 21 Supply & fixing of horizontal air termination (roof conductor) of 25X3mm GI strip, GI clamps on surface complete in all respect as approved by engineer in charge 22 Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on side and on top. On surface the cable run shall be fixed on M. S. clamps etc. of suitable size or as directed by the engineer-incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamp etc. 501 (e) 6 sq. mm 4 core 23 501 (n)95 sq. mm 3.5 core 24 501 (q) 185 sq. mm 3.5 core 25 Supply and fixing of 40Watt LED surface mounted weather proof Luminaire with PC Housing and opal finish cover conforming to IP 65 complete in all respect. 26 Supplying and laying of 1800mmX900mmX 12mm thick chequered rubber matting of tested quality 27 Supply & fixing of 7 mtr GI Octagonal Pole of approved make(top dia 70mm, Bottom dia 130mm and base plate 12mm thik) having 3mm thikness with single arm bracket (1 Mtr length) on RCC foundationincluding the cost of foundation, foundation bolts, excavation & back filling and Required T&P completee in all respect. 28 Supply & Erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN MCCBs (Four Pole 36 KA with thermal magnatic release)Switches Complete and instrument chamber etc.complete in all respects. The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters(KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above istulated with heat shrink sleeving and mountedon non hygroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. The MCCBs shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc.The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubicle type switch board shall be of cat A & B Only. Incoming 630 Amp. MCCB-1 NoOutgoing 02Nos.MCCB 200Amp., 02NOs. MCCB 100Amp. & 01Nos. MCCB 63 AMP.Cat. B. Pannel Cubicle Type 29 Supply & Erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN MCCBs (Four Pole 36 KA with thermal magnatic release)Switches Complete and instrument chamber etc.complete in all respects. The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters(KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above istulated with heat shrink sleeving and mountedon non hygroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. The MCCBs shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc.The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubicle type switch board shall be of cat A & B Only. Incoming 200 Amp. MCCB-1 NoOutgoing 02NOs. MCCB 100Amp.+ 02Nos. MCCB 100Amp.+ 02Nos. MCB 63Amp.Cat. B. Pannel Cubicle Type 30 S/F of LED street light fitting Mandatorydriver sethaving die cost aluminium body and lenses suitable for 110 to130 watt. Conforming to IP 66 protection having co. LOGO Engravedcomplete in all respect.including labour CAT AAA.12100-14300 system lumens, high power LED with lenses, >110lm/W, PF>0.95, THD<10% at full load, CRI>70 potted driver set(not circuitory) phase to phase protection at 440V & 300V auto cut & restartfeature with 5years warantee. 31 300 mm width X 50 mm depth X 1.6 mm thickness 32 600 mm width X 75 mm depth X 2.0 mm thickness 33 Supply & fixing of CO2 type fire extinguisher 4.5kg capacity (ISI marked IS 2878 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work(Contractor should submit test certificate form manufacturer along with serial number of every extinguishers supplied.) 34 Supply & fixing of fire extinguisher ABC Type 9.00Kg capacity (ISI marked IS 15683 & TAC approved complete with initial charge and wall bracket along with supply of all materials and labour for proper completion of works(Contractor should submit test certificate form manufacturer along with serial number of every extinguishers supplied.) 35 Supply & fixing of fire bucket, round bottom made of GI sheet 9-11 litres capacity duly painted as per fire brigade design, supported on hanging bracket chained and locked initially filled with fine river sand, water as per directions of Engineer in charge SI No. 1133 36 Supply & wiring with 2 nos 1.5 sq.mm FRLSH PVC insulated 1100V grade multistrand single copper conductor cable in 20mm dia heavy (2mm thick) PVC conduit with one number 1.5mm FRLSH PVC insulated 1100V grade multistrand copper conductor cable as earth continuity wire drawn inside the conduit. 37 Supply, Installation, testing & Commisioning of Analog addressableintelligent Firm Alarm Control Panel two loop complete with central processing module, RS 232/485 Network Communication Card, 8 lines by 21 character graphic LCD display with primary power supply at 230V with 24/36 volts Sealed Maintenance FRLSLSee (SMF) batteries back up (as per IS code) complete with solid state boost/trickle automatic battery charger.Address system with 4 character zonedswitch amplifier with battery back up as per technical specifications, drawings, detail and system description etc. 38 SSupplying, installation, testing & commissioning of smoke detector with builtin LED and mounting base complete with all connections etc. as required. 39 Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in A.B.S. box with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required. 40 Supplying, installation, testing & commissioning of manual call box of ABS type in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required. 41 Supplying, installation, testing & commissioning response indicator on surface/recess MS box having two LEDs metallic cover complete with all connections etc. as required. 42 Supply, installation, testing & commissioning of Diesel Generating Set of 125 KVA rating Silent Type Radiator type, suitable for of 415V, 3 phase 4 wire, 0.8 pf. (lagging) 50c/s A.C supply complete with engine (1500 RPM) and alternator DG Set controller with accessories including residential type silencer and manual control panel fuel service tank as per standard, battery and battery charger with all associated accessories including MCCB of suitable rating & standard set of tools and anti-vibration mounting pads etc. The specification shall be as per letest CPCB norm. 43 Supply of 1200 mm dia ceiling fan complete as required Crompton or equivalent as per approved makes. 44 Supply and fixing of PUF Insulation panel of thickness of80 mm,for Cold Room walls & ceiling including Common walls inclusive of all accessories as per specification for 03 Nos of Cold Room with 100 MT capacity (Dimenssion-16.0x6.1x3.5 mtr). Make – Lloyd insulation, Sintex, Rinac, JindalOr EquivalentBNAL (PUF Panel Thickness) a) Cold Room- 80 mm (walls) 80mm (ceiling)b)Density-40 +/- 2 Kg/M3c)Closed cell content-90 - 95%d)Thermal Conductivity -0.023 W/mke)Compressive Strength - 2.1kg/m2(at10% deformation)f)Water Vapour Permeability -0.8 -.12 gms/hr m2g)Fire Resistance-Self extinguishingh)Blowing Agent-CFC Freei)Sheet -0.5 mm TCT, PPGI) 45 Supply and fixing of Cold Room Floor with, Insulation Material- PUF slabof 80mm thickness( in 2 layers of 40 mm each), Vapour Barrier, inclusive of all accessories as per specification. Make - Lloyd Insulation,Sintex, Rinac, Jindal, BNAL,Industrial Foam Or Equivalent(a)Insulation Material-PUF slabb) Density - 40 +/- 2 Kg/M3c)No. Of Layers-2 layers ( 40 mm each)d)Total Thickness-80 mme)Vapor Barrier - Tarfelt, Polythene Sheet as per dwgf) VDF floor-VDF as per dwg) Sancctioned by Mandi Parishad 46 Supply and Installation of Cold Room Doors (for positive temp) insulated type of Horizontal Manual Sliding Door, Dimensions -1200 mm x 2100mm ( clear) with Sandwich panels constructed of a core of 80 mm PUF complete with all accessories as per specification Make - Metaflex, lloyd insulation, Rinac, Hormann, Gandhi Automation Or Equivalent (a) Type of Door-Manual Sliding Doorb)Dimensions - 1200 X 2100MMc)Type of panel- Sandwich panels constructed of a core of 80 mmPUF on both sides covered with 0.6 mm galvanized steel plate finished with 20mucoating. The panels are supplied with thermal bridge-free PVC surrounding profilesd) Sealing -All round with triple rubber profile (e)Colour outside -RAL 9002 (white)f)Colour inside -Standard colour RAL 9002 (white/grey)g)Hardware-Galvanised Steelh)Track Rail -Drop/Lift rail systemi)Finish of opening-To be Includedj)Door Operation - Manual) Sannctioned by Mandi Parishad 47 Supply and Installation of Ripening Room Doors insulated type of Horizontal Manual Swing Door, Dimensions -1200 mm x 2100mm ( clear) with Sandwich panels constructed of a core of 80 mm PUF complete with all accessories as per specification Make - Metaflex, lloyd insulation, Rinac, Hormann, Gandhi Automation Or Equivalent(a) Type of Door -Manual Sliding Doorb)Dimensions-1200 X 2100MMc)Type of panel-Sandwich panels constructed of a core of 80 mm PUF on both sides covered with 0.6 mm galvanized steel plate finished with 20mucoating. The panels are supplied with thermal bridge-free PVC surrounding profilesd) Sealing -All round with triple rubber profilee)Colour outside-RAL 9002 (white)f)Colour inside-Standard colour RAL 9002 (white/grey)g)Hardware-Galvanised Steelh)Finish of opening-To be Includedi)Door Operation - Manual)Sancctioned by Mandi Parishad 48 Supply, Installation, Testing, Commissioning of Refrigeration system of suitable capacity (reference capacity 27kw for each room) complete with all spares as per specification for each of 3 no cold room be provided with Freon 404A based refrigeration system to cater to theRefrigeration design load and suitable PLC System to control and monitor the operations as per specification for each of 3 nos cold rooms..1. DESIGN TEMP: EVAPORATION -7.5 DEG C, CONDENSING 53.5 DEG C2. COMPRESSOR – SCROLL (1 PER COLD ROOM)3. AIR COOLED CONDENSER, AIR VOLUME 10400 M3/HR, FANS TO BE CONTROLLED BY TEMP CONTROLLER , SUCTION 15/8”, LIQUID 7/8”. TYPICALDIMENSIONS : 1591MM (LENGTH) X 998MM (HEIGHT) X 1000MM (DEPTH) (MAKES- BITZER, BOCK, FRASCOLD, CARRIER)4. COOLERS OF CAPACITY 27 KW (1 PER COLD ROOM. WITH 3 AXIAL FANS OF 450MM, 19200 M3/HR, FIN SPACING 4 FIN/ SQ. INCH (MAKES – LUVE, PATTON,GUNTNER, STAR COOLER) – TYPICAL DIMENSIONS : 3500MM (LENGTH) X 655MM (HEIGHT) X 675MM (DEPTH)5. VENTILATION FAN 450MM6. CONTROLS, THERMOSTAT, SOLENOID VALVE, VALVE, SIGHT GLASS7. CONTROL PANEL FOR EACH ROOM AT REAR SIDE OF COLD ROOM CONTROL PANEL (PLC CONTROLS TYPE) TO HAVE FOLLOWING FEATURES – STARTINGARRANGEMENT FOR COMPRESSOR (HP/LP/OP CUT OUT FOR EACH COMPRESSOR) CONTRACTOR FOR CONDENSER FAN, THERMOSTATIC CONTROLLER FROM DANFOSS FOR CONTROLLING THE FAN, CRANKCASEHEATER TO OPERATE WHEN COMPRESSOR IS STOPPED AND OFF WHENRUNNING. LIGHTING MAIN SWITCH ALSO IN THE PANEL. THIS WILL HAVE ALL STARTERS WITH INTERLOCKING SYSTEM. PUSH BUTTONS FOR START/STOP. HUMIDIFIER & ETHYLENE SCRUBBER SWITCHES ALSO IN THE PANEL. OVERLOAD RELAYS & FUSES, NAME PLATES Sancctioned by Mandi Parishad 49 Supply, Installation, Testing & Commissioning of Ultrasonic type humidification system in allCold roomswith automated controls capable of providing 90 - 95% RH in each room to ensure uniform humidity in the room, system should be complete with RH control sensor and digital display for monitoring and control of RH in each room, , complete with all connections in all rooms as per specification - The humidification system offered should be ltrasonic type humidification system in allCold roomswith automated controls capable of providing 90 - 95% RH in each cold room to ensure uniform humidity in the room, system should be complete with RH control sensor and digital display for monitoring and control of RH in each room, complete with all connections in all rooms as per specification 50 Supply, Installation, Testing, Commissioning of Refrigeration Systemof suitable capacity (reference capacity16.00 kw for each room) complete with all spares and suitable PLC System to control and monitor the operations as per specification for each of 4 nos ripening rooms.(1. DESIGN TEMP: EVAPORATION -5 DEG C, CONDENSING 54 DEG C2. COMPRESSOR – SEMI HERMETIC (1 PER RIPENING ROOM) 3. AIR COOLED CONDENSER, AIR VOLUME 20000 M3/HR, 10 FINS/INCH, 1 AXIAL FAN TO BE CONTROLLED BY THERMOSTATIC CONTROL UNIT WITH OUTSIDE TEMP SENSING ARRANGEMENT . TYPICAL DIMENSIONS : 1000MM (LENGTH) X 837MM (HEIGHT) X 672MM (DEPTH)(MAKES- BITZER, BOCK, FRASCOLD, CARRIER, EMERSON) 4. DUAL DISCHARGE COOLER OF CAPACITY 16KW ( 1 PER RIPENING ROOM. WITH 5 AXIAL FANS OF 450MM, AIR VOLUME 20000 M3/HR, FIN SPACING 5 FIN/SQ. INCH MAKES –LAFA LAVAL, PATTON, GUNTNER, STAR COOLER) TYPICAL DIMENSIONS : 2500MM (LENGTH) HEIGHT OF INDIVIDUAL COIL 325MM 5. VENTILATION FAN 15”, 6. CONTROLS , DRYER, THERMOSTAT, THERMOSTATIC EXPANSION VALVE, SOLENOID VALVE, VALVE, SIGHT GLASS7. SENSORS & ALLIED EQUIPMENT PER ROOM -ETHYLENE SENSOR (1), CO2 SENSOR (1), PULP TEMPERATURE (1 ), VENTILATION SYSTEM CONNECTED TO DAMPER & VENTILATION FAN (1 EACH) 8. PIPING – SUCTION 11/8” AND LIQUID LINE ½” WITH INSULATION 9. CONTROL PANEL FOR EACH ROOM AT REAR SIDE OF RIPENING ROOM, 10. CONTROL PANEL (PLC CONTROL TYPE) TO HAVE FOLLOWING FEATURES – STARTING ARRANGEMENT FOR COMPRESSOR (HP/LP/OP CUT OUT FOR EACH COMPRESSOR) CONTRACTOR FOR CONDENSER FAN, THERMOSTATIC CONTROLLER FROM DANFOSS FOR CONTROLLING THE FAN, CRANKCASE, HEATER TO OPERATE WHEN COMPRESSOR IS STOPPED AND OFF WHEN RUNNING. LIGHTING MAIN SWITCH ALSO IN THE PANEL. THIS WILL HAVE, ALL STARTERS WITH INTERLOCKING SYSTEM. PUSH BUTTONS FOR START/STOP. HUMIDIFIER & ETHYLENE GENERATOR SWITCHES ALSO IN THE PANEL. OVERLOAD RELAYS & FUSES & NAME PLATES 51 Supply, Installation, Testing & Commissioning of Ultrasonic type humidification system in allRipening roomswith automated controls capable of providing 90 - 95% RH in each Ripening room to ensure uniform humidity in the room, system should be complete with RH control sensor and digital display for monitoring and control of RH in each room, complete with all connections in all rooms as per specification - The humidification system offered should be Ultrasonic type humidification system in allRipening roomswith automated controls capable of providing 90 - 95% RH in each room to ensure uniform humidity in the room, system should be complete with RH control sensor and digital display for monitoring and control of RH in each room, , complete with all connections in all rooms as per specification. 52 Supply, Installation, Testing and Commissioning of Portable Ethylene Generator connected to an electrical plug point inside the room, the Ethylene Generator should be suitable for providing suitable levels of ethylene (as per the fruit category) in ripening rooms of volume around 60 cum by catalytic dehydration of developing liquid into ethylene gas complete with suitable developing liquid required for commercial ripening applications for each of the ripening rooms as per specification alongwith 5 ltr of developing liquid ethylene with each generator. Make- Aseko, Catalytic, American Ripener Or Equivalent(The provision for Ethylene Gas dosage for ripening in each room shall be by placing a Portable Ethylene Generator connected to an electrical plug point inside the room. The Ethylene Generator should be suitable for providing suitable levels of ethylene (as per the fruit category) in ripening rooms of volume around 58 cum by catalytic dehydration of developing liquid into ethylene gas complete with suitable developing liquid required for commercial ripening applications.)Sanctioned by Mandi Parishad 53 Supply, Installation, Testing and Commissioning of Ethylene Gas sensor complete with display in all 4 Ripening Rooms of catalytic type with measuring range upto 2000 ppm for ripening room application as per specification.Make- Aseko, Carel Or Equivalent Sanctioned by Mandi Parishad 54 Supply, Installation, Testing and Commissioning of CO2 gas sensors complete with display in all 4 Ripening Rooms of infrared type with measuring range 0 – 5%suitable for ripening application as per specification.Make- Aseko, Carel Or Equivalent Sanctioned by Mandi Parishad 55 Supply, Installation, Testing and Commissioning of Air Ventilation Systems connected with gas control system for all Ripening Roomssuitable for ripening application as per specification Sanctioned by Mandi Parishad 56 Supply, Installation, Testing and Commissioning of RipeningController systemsensors for integration and control of all ripening activities suitable for minimum 4 ripening rooms with display & all accessories (Make: Aseko, Interko, Felix Or Equivalent)Sanctioned by Mandi Parishad 57 Supply and fixing of PUF Insulation panel of thickness of40 mm having Density 40 kg/cu.m (+/- 2), 0.5 mm thick PPGI sheet, thermal conductivity [ 0.023 W/mk], for ceiling at loading, unloadingand Admin area (3.5 mtr. Hight from floor level) inclusive of all accessories and installation as per specification. Make - Lloyd Insulation, Sintex, Rinac,Jindal Or Equivalent Sanctioned by Mandi Parishad 58 Supply, Installation, Testing and Commissioning of Platform weighscale of electronic digital type of 200 kg capacityas per specifications Make - Kantawala, Swastik, Dewlite, Avery (a) Capacity 200 Kgb)Pan Size & MOC 400mm X 500mm minimum (of SS) for 200 kge)Least Count 20 gm maximum for 200 kg h)100% Tare through Keyboardi)Stamping to be provided) Sanctioned by Mandi Parishad 59 Supply, Installation, Testing and Commissioning of hand pallet truck with 2500 kg lifting capacity as per specification Make - Godrej, Voltas, Mahindra, Jay, Maini (a) Load Capacity : 2500 mmb) Fork Length : 1100 mmc) Fork Width : 150 mmd) Out Side Fork Spread : 550 mme) Inside Fork Spread : 250 mmf) Maximum Fork Height : 185 mmg) Minimum Fork Height : 75 mm)Sanctioned by Mandi Parishad 60 Supply, Installation, Testing and Commissioning of Plastic Pallet of size : 1200 x 1000 x 160 mm with 4 way entry HDPE 100% virgin material Sanctioned by Mandi Parishad 61 Supply, Installation, Testing and Commissioning of Plastic crates of outer dimensions 540mm x 357mm x 290mm (48 ltr capacity) for storage of around 20 kg vegetables (side perforated type) made of HDPE 100% virgin material as per specificationsSanctioned by Mandi Parishad 62 Providing preventive maintenance, repair, replacement for all equipment for a period of 4 years after warranty periodSanctioned by Mandi Parishad 63 Providing skilled two manpower for the Management of proposed cold room & ripening chamber facility. The agency will be responsible for the management of facility in terms of accounting and etc for the first year.Sanctioned by Mandi Parishad 64 Providing skilled two manpower for the Management of proposed cold room & ripening chamber facility. The agency will be responsible for the management of facility in terms of accounting and etc for the 2nd year Sanctioned by Mandi Parishad 65 Providing skilled two manpower for the Management of proposed cold room & ripening chamber facility. The agency will be responsible for the management of facility in terms of accounting and etc for the 3rd year Sanctioned by Mandi Parishad 66 Providing skilled two manpower for the Management of proposed cold room & ripening chamber facility. The agency will be responsible for the management of facility in terms of accounting and etc for the 4th yearSanctioned by Mandi Parishad 67 Providing skilled two manpower for the Management of proposed cold room & ripening chamber facility. The agency will be responsible for the management of facility in terms of accounting and etc for the 5th yearSanctioned by Mandi Parishad 68 Providing unskilled, skilled manpower in two shifts for the management of proposed cold room and ripening facility the agencyThe agency will be responsible for the Operation of facility for the 1st year.(Sanctioned by Mandi Parishad) 69 Providing unskilled, skilled manpower in two shifts for the management of proposed cold room and ripening facility the agencyThe agency will be responsible for the Operation of facility for the 2nd year(Sanctioned by Mandi Parishad) 70 Providing unskilled, skilled manpower in two shifts for the management of proposed cold room and ripening facility the agencyThe agency will be responsible for the Operation of facility for the 3rd year (Sanctioned by Mandi Parishad) 71 Providing unskilled, skilled manpower in two shifts for the management of proposed cold room and ripening facility the agencyThe agency will be responsible for the Operation of facility for the 4th year(Sanctioned by Mandi Parishad) 72 Providing unskilled, skilled manpower in two shifts for the management of proposed cold room and ripening facility the agencyThe agency will be responsible for the Operation of facility for the 5th year(Sanctioned by Mandi Parishad)