| Sl. No. | Item Description |
| 1 | Excavation in trenches not exc 1.5m wide and not exc 1.5m deep for laying of GI/CI/DI pipe lines etc getting out including forming bottom surfaceto required level and gradient in soft / loose soil, complete all as specified and directed. |
| 2 | Returning and filling in excavated soil including spreading leveling, watering, well ramming in layers not exc 25 cm thick, complete all as specified and directed. |
| 3 | Removing of excavated materials not exceeding 50 Mtrs and depositing where directedat a level not exceeding 1.5 Mtrs above the starting point, complete all as specified and directed. |
| 4 | Complete, arrangement , transporting, accessories for carrying out of Chemical Analysis test including Bacteriological Examination of drinking water from following reputed Test house, The Sample of drinking water for testing shall be taken from following locations and submit the report to Engineer-in-charge on quarterly basis, complete all as specified and directed(a) Pump House No 1(b) Pump House No 2(c) Pump House No 7(d) Pump House No 8(e) Pump House No 9(f) Pump House No11(g) OP area NCs Qtr New Pump House No-13(h) Pump House No12 Map Qtr. Address of reputed laboratories are given below:-(i)The Shriram Institute for Industrial reasearch 19, University road Delhi-7(ii) Water TestingReasearch Laboratory Hisar Haryana.(iii) AFMC- PUNE (Deptt of PSM,Post Graduate Wing).(iv)Delhi Test House A- 62/3 G.T Road Karnal road Azadpur Delhi-33.(v)Any Govt laboratory as approved by GE. |
| 5 | Taking out / burning out of leakage and damaged lead joints in the existing CI mains including removing the old lead carefully with out damaging the pipe complete for 80 mm bore of pipes, complete all as specified and directed.Note :- Excavation and earth work will be measured and paid separately if repairs required to be carried out for joints only without taking out pipe. |
| 6 | All as per Srl item No. 5.00 above but 100 mm bore. |
| 7 | All as per Srl item No. 5.00 above but 150 mm bore. |
| 8 | All as per Srl item No. 5.00 above but 200 mm bore. |
| 9 | M&L for run lead joint including jointing materials such as spun, yarn etc complete for the 80 mm bore CI pipe, complete all as specified and directed. |
| 10 | All as per Srl item No. 9.00 above but 100 mm bore. |
| 11 | All as per Srl item No. 9.00 above but 150 mm bore. |
| 12 | All as per Srl item No. 9.00 above but200 mm bore. |
| 13 | Material and labour for repair of 15 / 20 /25 mm dia bore rubber gasket joints/Mechanical joints of G I pipeline including jointing materials unions, tees, bends, sockets, elbow and all others spares as required for stopping the leakage of pipeline below and taking down, complete all as specified and directed.Note :- Excavation and earth work will be measured and paid separately if repair carried out for joint only. |
| 14 | All as per Srl item No. 13.00 above but 40 mm bore. |
| 15 | All as per Srl item No. 13.00 above but 50 mm bore. |
| 16 | All as per Srl item No. 13.00 above but 80 mm bore. |
| 17 | All as per Srl item No. 13.00 above but 100 mm bore. |
| 18 | All as per Srl item No. 13.00 above but 150 mm bore. |
| 19 | All as per Srl item No. 13.00 above but 200 mm bore. |
| 20 | M&L for repairs to 80mmbore sluice valves such as replacement of unserviceable/warnout gland on stuffing box, rubber gasket of suitable size, filling or grinding to gate,replacement of worn out check nut, cleaning inside gate valve properly and remove scaling and other waste materials, replacement of worn out nut/bolts with washers,including testing of leakage and operation, complete all as specified and directed. |
| 21 | All as per Srl item No. 20.00 above but 100 mm bore. |
| 22 | All as per Srl item No. 20.00 above but 150 mm bore. |
| 23 | All as per Srl item No. 20.00 above but 200 mm bore. |
| 24 | Disconnecting and removing the unserviceable/wornout spindle from the sluice valve 80 mm dia after opening the nut and bolts and replace the same with new brass spindle of same size , length and turns including necessary fixing arrangements,testing and commissioning, complete all as specified and directed. |
| 25 | All as per Sl item No 24.00 above but 100mm dia |
| 26 | All as per Sl item No 24 above but 150mm dia |
| 27 | All as per Sl item No 24 above but 200mm diaNote for item No 05 to 27 :- The camplaints of leakage once intimated must be done/ repaired with in a period of 3 days failure to this will impose a penatly of Rs 1000/ per days of delay to the contractor. The contractor must have a team of minimum one x plumber and one helper to rectify the complaints of leakage and a supervisor to attend the office of Engr-in-charge in every 3 days and sign the site order book wrt complaints of leakages at any location, failing which a penalty of Rs 500 /- shall be imposed to the contractor. |
| 28 | S&F in replacement Cast iron sluice valve 80mm dia bore both end flanged with brass spindle and cast iron handle wheel,heavy duty , class PN-1.6 and fixing with existing pipe line including jointing material nuts, bolts, washers gasket, complete all as specified and directed. |
| 29 | All as per Srl item No. 28.00 above but 100mm bore. |
| 30 | All as per Srl item No. 28.00 above but 150mm bore. |
| 31 | All as per Srl item No. 28.00 above but 200mm bore. |
| 32 | Taking outexisting CI pipe 80mm bore (including all fittings) with spigot and socket ends and lead joints / flange joint including burning out joints and removing lead from the ground cleaning the pipes free from sedimentation/scaling etc for reusing the serviceable pipes complete all as specified and directed.Note :- Excavation and earth work will be measured and paid separately. |
| 33 | All as per Srl item No. 32.00 above but 100 mm bore. |
| 34 | All as per Srl item No. 32.00 above but 150 mm bore. |
| 35 | Laying only cast iron pipes 80mm dia (Serviceable pipes obtained from dismantling shall be reused in the work) complete all as specified and directed..Note : Joints and jointing material shall be measured and paid seperately. |
| 36 | All as per Srl item No. 35.00 above but 100 mm dia. |
| 37 | All as per Srl item No. 35.00 above but 150 mm dia. |
| 38 | M&L for CI pipe of 80mm bore with spiogt and socket ends centrifugally cast class LA suitable for lead jointslaid in trenches including necessary cut to length to match the existing fitting/pipes complete all as specified and as directed. |
| 39 | All as per Srl item No. 38.00 above but 100 mm bore. |
| 40 | All as per Srl item No. 38.00 above but 150 mm bore. |
| 41 | M&L for cutting the CI pipe 80mm dia and reducing the required length in positioning for insertion of new CI specials such as Tees/Reducers/Tail pieces/collers/sluice valve/Air release valve etc complete all as specified and directed. |
| 42 | All as per Srl item No. 41.00 above but 100 mm bore. |
| 43 | All as per Srl item No. 41.00 above but 150 mm bore. |
| 44 | M&L for CI/GI specials such as bends, tees, collars tail pieces flanges, etc complete suitable for CI/GI mains upto 200 mm bore sizes, complete all as specified and directed |
| 45 | M&L for Cast iron double flanged non slam roundtype non return valve 80mm bore with by pass arrangements heavy duty confirming to IS-5312 Part I / 84 of pressure rating PN 1.0 as in replacement complete all as specified and directed. |
| 46 | All as per Srl item No. 45.00 above but 100 mm dia bore. |
| 47 | All as per Srl item No. 45.00 above but 150mm dia bore. |
| 48 | All as per Srl item No. 45.00 above but 200mm dia bore. |
| 49 | S&F in replacement cast Iron flanged type foot valve 80 mm bore with drilled flanged end all as per IS : 4038 with Cast Iron Strainer, nuts, bolts, washers etc, complete all as specified and directed. |
| 50 | S&F in replacement cast Iron flanged type foot valve 100 mm bore with drilled flanged end all as per IS : 4038 with Cast Iron Strainernuts, bolts, washers etc, complete all as specified and directed. |
| 51 | M&L for cast iron detachable joint suitable for 80mm dia bore pipes of CI/GI/PVC Pipe including nuts,bolts and rubber ring etc conforming to IS : 8794 (CL-15), complete all as specified and directed |
| 52 | All as per Srl item No. 51.00 above but 100 mm bore. |
| 53 | All as per Srl item No. 51.00 above but 150 mm bore. |
| 54 | All as per Srl item No. 51.00 above but 200 mm bore. |
| 55 | Taking up or down steel water GI tubing 15mm dia bore and connections including clearing the pipes free from scaling for reusing the same complete all as specified and directed.Note : Excavation will be measured and paid seperately. |
| 56 | All as per Srl item No. 55.00 above but 20 mm bore. |
| 57 | All as per Srl item No. 55.00 above but 25 mm bore. |
| 58 | All as per Srl item No. 55.00 above but 50mm bore. |
| 59 | All as per Srl item No. 55.00 above but 80 mm bore. |
| 60 | All as per Srl item No. 55.00 above but 100 mm bore. |
| 61 | Relaying / refixing of old steel water tubing GI medium grade 15mm bore pipe with all newfittings such as bend, elbow, socket, nipple, tapers, reducers, unions etc as required,laid in trenches or fixed to wall etc complete all as specified and directed. |
| 62 | All as per Srl item No. 61.00 above but 20mm bore. |
| 63 | All as per Srl item No. 61.00 above but 25mm bore. |
| 64 | All as per Srl item No. 61.00 above but 50mm bore. |
| 65 | All as per Srl item No. 61.00 above but 80 mm bore. |
| 66 | All as per Srl item No. 61.00 above but 100 mm bore. |
| 67 | Supply and laying 15mm bore galvanised steel water tubing, medium grade with necesary fittings / fixtures laid in trenches or fixed to walls/ceilings, complete all as specified and directed. |
| 68 | All as per Srl item No. 67.00 above but 20mm bore. |
| 69 | All as per Srl item No. 67.00 above but 25mm bore. |
| 70 | All as per Srl item No. 67.00 above but 50mm bore. |
| 71 | All as per Srl item No. 67.00 above but 80mm bore. |
| 72 | All as per Srl item No. 67.00 above but 100 mm bore. |
| 73 | Taking up or down 150mm dia existing centrifugally cast (spun) ductile iron pressure pipes for water with socket and spigot ends suitable for rubber gasket pushon joining, complete all as specified and directed. |
| 74 | All as per Sl item No 73 above but 100mm dia. |
| 75 | Supply and laying 150mm dia centrifugally cast (spun) ductile iron pressure pipes for water with socket and spitot ends suitable for rubber gasket pushon joining confirming to IS 8329:2000 having inside cement mortar lining and outside zinc coating with finishing layer of blue epoxy in standard length, classification K-9 in standard length of 5.50/6.0 meter including push on joints with cement mortar (1:2) lining, complete all as specified and directed. |
| 76 | All as per Srl item No. 75.00 above but except pipe.Note : Serviceable pipes obtained from Sl item No 73 above shall be reused in this item. |
| 77 | Supply and laying 100mm dia centrifugally cast (spun) ductile iron pressure pipes for water with socket and spitot ends suitable for rubber gasket pushon joining confirming to IS 8329:2000 having inside cement mortar lining and outside zine coating with finishing layer of blue epoxy in standard length, classification K-9 in standard length of 5.50/6.0 mtrs including push on joints with cement mortar lining complete all as specified and directed. |
| 78 | All as per Srl item No. 77.00 above but except pipe. Note : Serviceable pipes obtained from Sl item No 77 above shall be reused in this item. |
| 79 | S&F in repairs 15mm dia bore Gun metal gate valve with iron wheel head screwed both ends for iron pipes and fixed, complete all as specified and directed. |
| 80 | All as per Srl item No. 79.00 above but 20mm bore. |
| 81 | All as per Srl item No. 79.00 above but 25mm bore. |
| 82 | All as per Srl item No. 79.00 above but 40mm bore. |
| 83 | All as per Srl item No. 79.00 above but 50mm bore. |
| 84 | S&F in repairs 15 mm bore Stop valve, cast copper alloy,screwed down high pressure with crutch or butterfly handle screwed both ends complete suitable for the of pipe, complete all as specified and directed. |
| 85 | All as per Srl item No. 84.00 above but 20 mm bore of pipe |
| 86 | All as per Srl item No. 84.00 above but 25 mm bore of pipe |
| 87 | Dismantling the water mains from the delivery lines, lifting/taking up GI/UPVC Column pipes, pumping sets including submersible cable after disconnecting pumping sets of capacity 20 HP to 25 HP, repairs tothe defective submersible cable andjointing of submersible cable by using water proofing jointing kit, transporting the pumpset to civil workshop and back to site after repairs, replacement of defective column pipes, and including Loweringof submersible pump Sets, submersible cable, column pipes, reonnecting main delivery mains as existing and testing for satisfactory running and continuous flow of water etc complete all as specified and directed at bore wells at various location in domestic area. Note :- Repair to Motor & Pumping sets shall be measured and paid seperately. Column pipes as required for replacement shall be measured and paid separately under relevant item of schedule. |
| 88 | Dismantaling the submersible pumpset of capacity 20 HP to 50 HP forservicing/repairs,replacement of defective parts, reassembling the motor properly and testing for satisfactory running, working with continuous flow of water etc including replacement of unserviceable suitable MS stud with nuts complete all as specified and directed.Note : Spare parts will be measured and paid under relevant item of schedule as \"Supply only\". |
| 89 | M&L for rewinding the Submersible motor using required SWG of PVC insulated copper wire, making winding leak proof with superior quality insulating materials, properly jointing terminals with submersible cable, etc of capacity upto 25 HP etc, complete all as specified and directed. |
| 90 | All as per item No 89 above but capacity 30 HP. |
| 91 | All as per item No 89 above but capacity 35 HP. |
| 92 | All as per item No 89 above but capacity uoto 50 HP. Note:- Motor of any site undergone repair/rewinding will be liable for repair again free of cost in case of same fault occuring during the engagement of contract period.Repair/rewinding of the motor will be measured only once for a particular site/motor.The downtime at site/time required for repair of motor if is more than 24 hrs, the contractor willbe liable to provide & install a standby motor of same capacity & descriptions & make / model No. at site during the downtime with no extra cost to the department failing to this the contractor will be liable to penalty of Rs 500/- every hour post 24 hrs repair timeline. |
| 93 | Part of Submersible pumpset of capacity 20 HP to 50 HP :- Supply only Gun metal impeller, complete all as specified and directed. |
| 94 | Supply only CI stage bowl, complete all as specified and directed. |
| 95 | Supply only Brass neck ring, complete all as specified and directed. |
| 96 | Supply only Thrust pad, complete all as specified and directed. |
| 97 | Supply only Distance sleeve, complete all as specified and directed. |
| 98 | Supply only Motor bush, complete all as specified and directed. |
| 99 | Supply only Sealing kit, complete all as specified and directed. |
| 100 | Supply only Thrust plate, complete all as specified and directed. |
| 101 | Supply only Pump coupling stainless steel with key, complete all as specified and directed. |
| 102 | Supply only Sand guard, complete all as specified and directed. |
| 103 | Supply only Stud & Nut, complete all as specified and directed. |
| 104 | M&L for dismantling the water mains from the delivery lines, lifting/taking up GI/UPVC Column pipes, pumping sets including submersible cable after disconnecting pumping sets 0.5 to 5 HP, repairs tothe defective submersible cable andjointing of submersible cable by using water proofing jointing kit, transporting the pumpset to civil workshop and back to site after repairs, replacement of defective column pipes, and including Loweringof submersible pump Sets, submersible cable, column pipes, reonnecting main delivery mains as existing and testing for satisfactory running and continuous flow of water etc complete all as directed by Engineer in charge at bore wells at various locations under GE (AF) Halwara. Note: Repair to Motor & Pumping sets shall be measured and paid seperately. Column pipes required for replacement shall be measured and paid separately under relevant item of schedule. |
| 105 | Dismantaling the submersible pumpset of capacity 0.5 HP to 5 HP forservicing/repairs,replacement of defective parts, reassembling the motor properly and testing for satisfactory running, working with continuous flow of water etc including replacement of unserviceable suitable MS stud with nuts complete all as specified and directed.Note : Spare parts will be measured and paid under relevant item of schedule as \"Supply only\". |
| 106 | M&L for rewinding of Submersible motor using required SWG of PVC insulated copper wire, making winding leak proof with superior quality insulating materials, properly jointing terminals with submersible cable, etc of capacity 0.5 to 5 HP etc, complete all as specified and directed.Note:- Motor of any site undergone repair/rewinding will be liable for repair again free of cost in case of same fault occuring during the engagement of contract period.Repair/rewinding of the motor will be measured only once for a particular site/motor.The downtime at site/time required for repair of motor if is more than 24 hrs, the contractor willbe liable to provide & install a standby motor of same capacity & descriptions & make / model No. at site during the downtime with no extra cost to the department failing to this the contractor will be liable to penalty of Rs 500/- every hour post 24 hrs repair timeline. |
| 107 | Part of Submersible pumpset of capacity 0.5 HP to 5 HP.Supply only Gun metal impeller, complete all as specified and directed. |
| 108 | Supply only Stainless steel shaft, complete all as specified and directed. |
| 109 | Supply only Thrust pad, complete all as specified and directed. |
| 110 | Supply only Distance sleeve, complete all as specified and directed. |
| 111 | Supply only Motor bush, complete all as specified and directed. |
| 112 | Supply only Pump coupling stainless steel with key, complete all as specified and directed. |
| 113 | S & F in repair MS column pipe medium grade of size 100mm dia 10\" long flanged both ends and slot made for submersible cable, complete all as specified and directed. |
| 114 | All as per item No 113 above but for 125 mm dia. |
| 115 | Opening and disassembling CF pump from electric motor 20 HP capacity, including shifting, transportation, overhauling shaft metering, welding, brazing and grinding the shaft and replacing of worn out parts and re-assembling and connecting it to the electric motor, complete all as specified and directed. Note : (i) The unit rate shall deemed to be included for minor spares such as bolts, nuts washers, oil seal, gasket, greasing etc as required.(ii) Major spares as required shall be measured and paid for separately. |
| 116 | All as per item No 115 above but 5 to 12.5 HP. |
| 117 | All as per Srl item No. 115.00 above but 0.5 to 3 HP.Note :- The rate of booster motor shall deemed to be included in quoted rate. |
| 118 | Rewinding of electric motor of capacity upto 5 HP for centrifugal non clog pumping set with supper enameled copper winding wire of existing gauge, size and weight with insulating material complete all as specified and directed. |
| 119 | All as per item No 118.00 above but capacity above 5 HP to 12.5HP |
| 120 | All as per item No 118.00 above but capacity above 12.5 HP to 20 HP Note for Srl Item No 117, 118 & 119.:- Motor of any site undergone repair/rewinding will be liable for repair again free of cost in case of same fault occuring during the engagement of contract period.Repair/rewinding of the motor will be measured only once for a particular site/motor.The downtime at site/time required for repair of motor if is more than 24 hrs, the contractor willbe liable to provide & install a standby motor of same capacity & descriptions & make / model No. at site during the downtime with no extra cost to the department failing to this the contractor will be liable to penalty of Rs 500/- every hour post 24 hrs repair timeline. |
| 121 | Supply only MS coupling with rubber bush and coupling nuts & bolts for 20 HP non clog pumping set, complete all as specified and directed. |
| 122 | Supply only Impeller GM for 20 HP CF pumping set, complete all as specified and directed. |
| 123 | Supply only Gland box for 20 HP CF pumping set, complete all as specified and directed. |
| 124 | Supply only ball bearing for 20 HP non clog pumping set, complete all as specified and directed. |
| 125 | Supply only Ball bearing of electric motor upto 12.5 HP capacity, complete all as specified and directed. |
| 126 | Supply only Gun metal bushesof pump upto 12.5 HP capacity, complete all as specified and directed. |
| 127 | Supply only MS couplingof pump upto 12.5 HP, complete all as specified and directed. |
| 128 | Supply only Ball bearing of electric motor upto 5 HP capacity, complete all as specified and directed. |
| 129 | Supply only Gun metal bushes of pump upto 5 HP capacity, complete all as specified and directed. |
| 130 | Supply only Rubber couplingof pump upto 5 HP, complete all as specified and directed. |
| 131 | S&F in replacement Butterfly valve of size 200/300 mm dia, complete all as specified and directed. |
| 132 | S&F in replacement Butterfly valve of size 150 mm dia, complete all as specified and directed. |
| 133 | S&F in replacement Butterfly valve of size 100 mm dia, complete all as specified and directed. |
| 134 | S&F in replacement Butterfly valve of size 80 mm dia, complete all as specified and directed. |
| 135 | S&F in replacement Single Phase Preventer, complete all as specified and directed. |
| 136 | S&F in replacement Shunt Capacitor suitable for Motor uoto 50 HP capacity, complete all as specified and directed. |
| 137 | S&F in replacement Hand Wheel for Actuator suitable for200mm / 150mm /100mm / 80mm dia Butterfly Valve, complete all as specified and directed. |
| 138 | S&F in replacement fully automatic star delta starter of range 17-24 relay rating, 3 phase, 415 volt, in sheet metal enclosure with Surge Protection Device, Single phase preventor 50 Hz, suitable for 20 to 50 HP capacity submersible pump set, complete all as specified and directed. |
| 139 | S&F in replacement fully automatic Auto start Direct on Line starter in SS (stainless Steel) enclosure with 230-400 V Coil Overload relay range 3.8/6.0 A Back up Fuse (A)20 Suitable for Submersible motor upto cap3 HP, complete all as specified and directed. |
| 140 | S&F in replacement fully automatic Auto start Direct on Line starter in SS (stainless Steel)enclosure with 230-400 V Coil Overload relay range 6.0/9.3/3.8 A Back up Fuse (A) 25 suitable for Submersible motor capacity 5/3.7 HP, complete all as specified and directed. |
| 141 | S&F in replacement fully automatic Auto start Direct on Line starter in SS (stainless Steel) enclosure 8.9-13.5 A with 230-400 V Coil Overload relaysuitable for CF Pump upto 10 HP, complete all as specified and directed. |
| 142 | S&F in replacement fully automatic Auto start Direct on Line starter in SS (stainless Steel) enclosure 6.0-9.3 A with 230-400 V Coil Overload relaysuitable for CF Pump upto 20 HP, complete all as specified and directed. |
| 143 | S&F in replacement single phase 1.5 HP relay 8.9-13.5 contactor rating 16 Amp SPS with 2P contactor + overload relay (Ammeter + Voltmeter) wiogh 160-220 V AC coil, complete all as specified and directed. |
| 144 | Supply only 2.5 sqmm single core cable Yellow, HRFR, PVC flexible cable, complete all as specified and directed. |
| 145 | Supply and fixing in replacement of Isolator single pole 32 Amp, complete all as specified and directed. |
| 146 | S&F in replacement MCB SPN 06 to 40 Amp 415 V including all terminals fitting etc, complete all as specified and directed. |
| 147 | S&F in replacement single core PVC insulated unsheathed stranded copper FRLS conductor of size 06 sqmm 1100 volts grade confirming to IS 694-1990, complete all as specifiedand directed. |
| 148 | All as per item No 147 here-in-before forbut Size 10 Sqmm. |
| 149 | All as per item No 147 here-in-before forbut Size 16 Sqmm. |
| 150 | S&F First Aid chart with clear glass cover & wooden frame, complete all as specified and directed. |
| 151 | All as per item No 150 but shock treatement chart. |
| 152 | Supply Only First Aid Kit box No-08 (Size : 360 mm x 150 mm x 80 mm) caintaining following items:-(a) Dettols bottle100 ml 02 bottles(b)Antiseptic Ointment 100 mg(c) Crocin tabletes 01 strips ( containings 10 Tablets each).(d) Hydrogen peroxide 50 ml 01 bottle (e) Cotten small rolls 2 Nos(f) Cotten strip small roll 04 Nos(g) Moove tube 01 Nos(h) Betadine Tube 100 mg |
| 153 | Supply only orthotodoline solution for chlorine test in 500 ML bottle, complete all as specified and directed. |
| 154 | Supply only Chlorine gas test kit up to 2 PPM, complete all as specified and directed. |
| 155 | S&F Submersible Cable 2.5 Sqmm, flat three Core, PVC Insulated & PVC Sheathed copper conductor 1100 Volts for Submersible Pump Moter, complete all as specified and directed. |
| 156 | All as per item No 155.00 here-in-before for but 4 Sqmm. |
| 157 | All as per item No 155.00 here-in-before for but 6 Sqmm. |
| 158 | All as per item No 155.00 here-in-before for but 10 Sqmm. |
| 159 | All as per item No 155.00 here-in-before for but 16 Sqmm. |
| 160 | All as per item No 155 here-in-before for but 25 Sqmm. |
| 161 | M&L for preparation, cleaning, painting of Overhead tank surfaces, out side and in side with one coat of exterior acrylic emulsion including preparartion of surfaces of RCC over head reservoir as per exixting color code, from ground level to bottom of the dome of the tank, including painting to raising/delievery/wash out/over flow CI/GI pipe line 80/100/150 mm dia with one coat of synthetic enamel paint including preparation of surfaces complete removing of all scale & dirt from bottom & walls and from mouth of circulation pipes of overhead tank of capacity 1,00,000.00 gallons at staging height exceeding 15 metre and not exceeding 21.5 metre and disinfecting the same using disinfecting chemical (chlorine) including writing date of cleaning with white colour over black colour base of synthetic enamel paint \"Pump house No-01\". Also including closing of opening at pressure release/Air passage using galvanised mild steel wire cloth,0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks,or galvanised wire staples not exceeding the total qty of 15sqm each job, complete all as specified and directed. Note :- The rate quoted shall deemed to be included the cost of neccessary scaffolding, supports etc. |
| 162 | All as per item No-161.00 as mentioned above but semi under ground sumps 50000 Gallons at 60 ft staging at pump house - 08 near Officer Gate, OP area NCEs Qtr New Pump House.No-13 and at pump house -9 Rattowal Complex. |
| 163 | All as per item No-162.00 as mentioned above but semi under ground sumps 75000 Gallons at 60 ft at pump house -7Officers Enclave. and at pump house -11 Near MES MT. |
| 164 | All as per item No-162.00 as mentioned above but semi under ground sumps 100000 Gallonscapacity of semi under ground sump staging atKK Ground Pump House No-12. |
| 165 | All as per item No-162.00 as mentioned above but semi under ground sumps 100000 Gallonscapacity of semi under ground staging atRP Area. |
| 166 | All as per item No-162.00 as mentioned above but semi under ground sumps 11000gallonscapacitymounted on multi storey Bldg at MAP Md Accn. |
| 167 | Supply, Fixing & installation in replacement of Chlorine dozing system, Non-metallic soluion tank of 100 Itrs capacity with motor driven agitator to maintan uniform suspension throughout the tank, elecrically operated chlorine dosing tank consisting Dosing tank 100 ltrs of PE/FRP MOC with PE/FRP Lid & level gauge along with single phase electric motor and agitator, 90 watts, 1440 RPM, 230 Volts, 50 cycles, 02 Amp and having speed controller to reduce speed upto 800 RPM, with shaft & blade in plasic-mounted on tank. Lid must have port hole for pouring calcium hypochlorite and waterwhen necessary. Lid must have provision for mounting dosing pump on the lid/wall incuding High pressure Single head Gear Motored adjustable Dosing Pump Set, uneffected on dry running having no loss of prime, independent of back pressure and able to handle both chemical solutions as well as suspension, 230 volts, 50 cycles, AC, 44 Rpm, 1/30 fracion HP having output 2US GPD to 40 U.S GPD complete with accessories i.e. lead tubing, connecting nuts, injecion check valve, clay weight and ferrules incuding complete installation, complete all as specifed and directed. |
| 168 | Supply only Calcium based hypochlorite (65%-70% Calsium based white to off white, free flowing, solid granular, chlorination chemical) in 45 Kg packing, complete all as specified and directed. |
| 169 | Disconnecting three phase power supply from LT panel and takikng out submersible pump motor set of capacity 20 to 50 HP alongwith column pipe and submersible cable including provision of developing of bore well for cleaning of water with help of air compressor maching of rating pressure capacity upto 250 PSI/550 cfm till the borewell found sand free and clear water is obtained from the borewell and all the blockage removed from the stainer pipes including opening upto the borewell depth upto 400 feet and reassembling all the column pipe and pump with motor duly fixed with submersible cable joints and replacement of all defective nuts/bolts/washers/gasket packing etc including lowering the electrical connections, complete all as specfied and directed. |
| 170 | S & F in replacement Ammeter 25 A for three phase submersible pump starter, complete all as specified and directed. |
| 171 | S & F in replacement Ammeter 50 A for three phase submersible pump starter, complete all as specified and directed. |
| 172 | S & F in replacement volt meter 0-500 volts for three phase submersible pump starter, complete all as specified and directed. |
| 173 | S & F in replacement volt meter 0-300 volts for three phase submersible pump starter, complete all as specified and directed. |
| 174 | Supply and fix in replacement of battery 150 AH 12 volt, complete all as specified and directed. |
| 175 | S & F in replacement MCCB 4 Pole 100 Amp breaking capacity ICU at 415 (50 KA), complete all as specified and directed. |
| 176 | S & F in replacement MCCB 4 Pole 250 Amp breaking capacity ICU at 415 (50 KA), complete all as specified and directed. |
| 177 | S & F in replacement MCCB 4 Pole 200 Amp breaking capacity ICU at 415 (50 KA), complete all as specified and directed. |
| 178 | S & F in replacement MCCB 4 Pole 160 Amp breaking capacity ICU at 415 (36 KA), complete all as specified and directed. |
| 179 | S & F in replacement MCCB 3 Pole 100 Amp breaking capacity ICU at 415 (36 KA), complete all as specified and directed. |
| 180 | S & F in replacement MCCB 3 Pole 63 Amp breaking capacity ICU at 415 (36 KA), complete all as specified and directed. |
| 181 | S & F in replacement off load change over switch AC-21 200 Amp side handle in sheet encloser, 415 V AC, 50 Hz, complete all as specified and directed. |
| 182 | S & F in replacement off load change over switch 100 A AC-23 side handle in sheet encloser, 415 V AC, 50 Hz, complete all as specified and directed. |
| 183 | S & F in replacement off load change over switch AC-21 400 Amp side handle in sheet encloser, 415 V AC, 50 Hz, complete all as specified and directed. |
| 184 | S & F in replacement power contactor 3 pole AC control AC-3 rating 32 Amps (20 HP/15KW) 415 volts including Aux contact 1 No + NC with coil voltage 380/415 volts, complete all as specified and directed. |
| 185 | S & F in replacement power contactor 3 pole AC control AC-3 rating 40 Amps (20 HP/15KW) 415 volts including Aux contact 1 No + NC with coil voltage 380/415 volts, complete all as specified and directed. |
| 186 | S & F in replacement power contactor 3 pole AC control AC-3 rating 63 Amps (50 HP) 415 volts including Aux contact 1 No + NC with coil voltage 380/415 volts, complete all as specified and directed. |
| 187 | S & F in replacement Electronic timer for three phase submersible pump starter, complete all as specified and directed. |
| 188 | S&F in replacement PVC (heavy) dutyelectric cables with copper Conductor 1100 volts cross section area 6 sqmm 3 core, complete all as specified and directed. |
| 189 | M&L for boring under road/path/hard standing to pass the Pipe linesupto 150mm dia bore with mechanical means and own arrangement of T&P, complete all as specified and directed. |
| 190 | M&L for cleanning of UG static water tank of approximate capacity up to 20000gallons indomestic area afterdewatering the tank using diesel engine pump sets and cleaning with a steel wire brush, removing mud, sludge, foreign articles, ulgi etc and sand upto bottom level and wash with bleaching powder solution and applying one coat of white wash inside of tank including writing date of cleaning with while colour over black colour base of synthatic enamel paint, complete all as specified and directed. Note :- (i) Sludge /waste material shall be thrown away from SWT premises from outside of MoD land where directed by Engr-in- charge. (ii) The cost of bleaching powder and cleaning solution shall deemed to be included in quoted rate. |
| 191 | S&F in repair copper thimbles of size 6 to 25 sqmm conductor, complete all as specified and directed. |
| 192 | S&F in repair aluminium thimbles of size 6 to 50 sqmm conductor, complete all as specified and directed. |
| 193 | S&F in replacement15mm dia bore High density polyethylene pipes(HDPE) of pressure rating 6kgf/cm2 laid in trenches / borewell, complete all as specified and directed. |
| 194 | All as per item No 193 abovebut 20 mm dia bore. |
| 195 | All as per item No 193 above but 25 mm dia bore. |
| 196 | All as per item No 193 above but 40/50 mm dia bore. |
| 197 | M&L to preparation of old painted surface of steel and applying one coat of synthetic enamel paint, complete all as specified and directed.Note : Colour of paint shall be stricity as per existing colour. |
| 198 | S&F distribution chart / electronic board for water/electrical distribution network to the writing letter locations, complete all as specified and directed. |
| 199 | M&L pressure gauge for pump at pump houses / tubewell, complete all as specified and directed. |
| 200 | M&L for writing letter or figures over RCC OH tank /sign board surface or iron surface or any other loc near pump house ( block, roman or italic not exceeding 90cm height), complete all as specified and directed. |
| 201 | Supply, fabricate and fixing in replacement Mild steel workconforming to Fe-290, E-165 as in framed grills, gratings, framed guard bars, ladder, frame work of water tanks etc or similar work as ordered and febricated from MS rolled section of any size and shape, complete all as specified and directed. Note: MS sheet where required shall be measured and paid seperately. |
| 202 | S&F in repair mild steel plate / sheet plain or chequered 3.00mm thick cut to piece as required and fixed to MS frame work be means of electric arc / gas welding, complete all as specified and directed. |
| 203 | M&L Masonary valve pit of size 1.2x1.2x1.1 m (internal size), PCC 1:4:8 type D2 using 40mm graded stone aggregate for foundation, brick wall with sub class `B’ bricks built in cement mortar 1:6, PCC 1:2:4 type B1 using 20mm graded stone aggregate for coping, rendering in cement mortar (1:4), 15mm thick including provision of MS sheet cover 2mm thick fixed to MS angle frame made out of 50x50x6mm thick with 2 coats of synthetic enamel paint over one coat of red oxide primer to steel surfaces and locking arrangementsincluding dismantling old one with necessary excavation and earth work in any type of soil, complete all as specified and directed. |
| 204 | All as per item No 203 above but Size 0.9x0.9x.86 m. |
| 205 | Supply, installation, testing and commissioning in replacement LT panel, indoor cubical type, weather and vermin proof, totally enclosed, made out of 3.15 mm thick CRCA sheet, machine preesed of suitable size, suitable to operate on 3 phase 4 wire system, 415 volts, 50 Hz with front and rear openable with locking arrangement including shutters for mounting switchgear etc, bottom gland plate with sufficient numbers of circular cable entry holes, prewired complete duly powder coated with 7 tank process, CPRI approved mounted on angle iron stand made out of angle size 50 x 50 x 6 mm grouted in PCC (1:3:6) 450mm above ground level, 400 mm below ground level comprising with following complete all as specified and directed :-(a) Bus bar strip, four pole and capacity 250 Amps copper strip size be based on 1.5 Amps per sqmm, coloured with plastic coated insulated and sleaves in four colours (Red, Yellow, blue and black) fixed on porcelain insulators with necessary nuts and bolts and washers etc.(b) Indicator with LED lamps for RYB, 3 phase with MCBs set of three-01 Set.(c) INCOMING(i) MCCB 125 Amp, 415 V, 25 KA, 4 pole with microprocessor release - 02 Nos.(ii) Panel meter of size 96 x 96 mm with LCD display, accuracy class 1.0, having parameters voltage, current, frequency, power factor, power & energy with RS 485 including suitable CT complete all as specified, duly prewired with suitable size of copper insulated FRLS wire with universal code including suitable CTs complete. |
| 206 | (d) OUTGOING(i) MCCB 100 Amp, 415 V, 25 KA, 4 pole with adjustable thermal magnetic release-02 Nos.(ii) Onload changeover switch 100 A, 4P 415 V open execution type -01. (iii) MCB SPN 32 Amp, 240 V, 10 KA, 02 Nos. (iv) MPCB 63 A -01.(v) SP preventor- 01. (vi) Automatic Star delta starter three phase 36-120A - 01 Nos. |
| 207 | M&L earthing in replacement for LT Panel / Feeder Pillars with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick burried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of the earth plate at a depth not less than 1.5 metre below ground level earth plate surrounded by 15cm thick and packed with layer of charcoal dust and common salt, earth lead GI strip 32mm x 6mm by means of bolts, nuts, check nuts and washers of galvanised iron and thimbles and other end connecions to main switch board and protected by galvanised iron, light grade, 50mm dia pipe, 20mm dia pipe for water with funnel, wire mesh, PCC chamber in cement concrete (1:3:6) using 20mm graded stone aggregate and 50mm thick RCC cover (1:2:4) type B-1 using 20mm graded stone aggregate and 8mm dia TMT bar @ 10cm c/c both way including MS frame using MS angle of size 45mmx4mmx5mm, exposed steel surfaces shall be painted with 2 coats of synthetic enamel paint over a coat of red oxide primer complete all as shown in electrical plate No-3in MES Schedule (Part-I), complete all specified and directed.Notes - (i) Outer edge of earth pit will be 1.5 metre away from the outer edge of PCC chamber. (ii) GI wire upto DBs earth connection is included in this item. (iii) Water pipe shall be provided in slantling position.(Earth strip and protection pipe upto 7.50m length is included in the quoted rate). |
| 208 | S&F in replacement LED aviation obstruction light fitting 302 LED IP 55 with all accessories, including giving power supply / connection to the light using 3 multi core copper wire of length as required, brackets for fixing arrengement etc. on over head tank, complete all as specified & directed. Note :- Payment of this item will only be made post successful testing of the obstruction light by Engr-in-charge. Rate of all accessories will deemed to be included in quoted rate. |
| 209 | Supply, fixing, testing and commssioning electonic water level indicator device sensor system with LED, 10 level showing water level in cm/mtr (before overflow) as per predetermined limits and power failure, complete with all accessories, complete all as specified and directed. |
| 210 | S&F in replacement aluminium strip of size 25mm x 3 mm with new saddle and fixing with screw for roof conductor/down conductor above ground, complete all as specified and directed. |
| 211 | S&F in replacement test point terminal block made of gun metal or phosphorus size 75mm x 75mm x25mm duly drilled and screwed including provision of nuts, bolts etc, complete all as specified and directed. |
| 212 | S & F in replacement air termination rod single pointed aluminium of dia 12mm and 300 mm long, complete all as specified and directed. |
| 213 | M&L in replacement energy saving & environmental friendly long life versatile pressure die-cast aluminium housing luminaire with heat resistant glass and suitable optics for uniform distribution of light 45/60 watt LED for bldg security lights with high efficiency electronic driver BIS approved, having IP-65/66 protection, surge protection min 2 KV power factor more than 0.9 complete operative on AC supply 140 volts to 270 volts pre-wired and product should be made in India only including GI pipe medium grade 40mm dia 1.2 mtr long bend to shape as required and fixing with two nos MS clamp of size 40x6mm for fixing of street light fitting, complete all as specified and directed. |