Tender For Day To Day Complaints Of External Elect Supply And Allied Works Flaming Arrow Bde At Nams- 1 Day to day attending complaints & maintaining the electric supplyGE NAMS Arearound the clock (24 Hours) comprising the followingelectrical distribution net work / transformers / LT panelsby contractor/his rep with fwg networks:-(i) Feeder No-1 emanating from MRS to TOP I,Appx length – 0.3 Km.(ii) Feeder No-2 emanating from MRS to AD feeder,Appx length = 4.8 Km, LT Panels , LT overhead lines appx – 2.50 km and 02 No transformer. (iii) Feeder No 03 emanating from TOP I Sub stationto Old Officer colony Feeder,Appx length = 3 Km along with 08 transformers with GOD s of different capacities , LT Panels , LT overhead lines appx – 4.5 km. (iv) Feeder No 04 emanating from TOP I Sub stationto Back Feeder Appx length = 3 Km alongComplete upto end point.(v) Feeder No 05 emanating from TOP I Sub stationto Old Mehta colony Appx length = 2 Km complete upto end point(vi) Feeder No 6 emanating from TOP I Sub stationto Mech FeederAppx length = 3 Km complete upto end point(vii) Feeder No 7 emanating from 66 KV MRS to Lower Line Offr Qtr - Approx 5.5 Km Complete upto end point.(Viii) Feeder No 8 emanating from 66 KV MRS to Khetrapal Sub stationAppx length = 2.5 Km complete upto end points 2 (ix) Feeder No 9 emanating from TOP II Sub stationto CP -6 baffle range Appx length = 4 Km complete upto end points.(x) Feeder No 10 emanating from 66 KV Sub stationto New Red Colony, New Kathania & NOC-I Appx length = 2.5 Km complete upto end points.Preodicity- round the clock.(B) Nature of work to be done(i) Maintaining the serviceability and attending break down complaints of electric supply of all the feeder including of New ASR Cantt areamentionedunder Sl 1.0(i) to 1(x) here in before .(ii) Attending the complaint ofexternalelectric supply – from sub station to main board / DB of the occupant.(iii) Periodical maintenance/complaints of all the feedersmentionedhere-in-before which includes – (a)Replacement ofoverheated jumper / blown off jumpers .(b) Replacement of blown off fuses .(c ) Periodical complaints of LTpanels .(f) Complaint to be attended within 1 to 2 hrs otherwise penaltyto be made at @ Rs. 500/- per complaint.(g) Complaint Register & complaint slip shall be provide by the contractorwihout any extra cost paid to himand maintained by the SBA on duty/ Contractor rep present at Complaint cell in supervison ofJEEM and signature of JE / Engr in charge will be taken on each complaint after completion of complaint on daily basis 3 Note :- No extra cost shall be paid to the contractor for complaint register and complaint slip.Note – (i) Timeconsumingjobs such as replacement ofdefective cable by extension of loop and periodicaltrimming of trees / branches along the over head lines shall be measured and paid separately .(ii) Before attending any complaints of external elect supply contractor or his rep shall ensure that proper shut down has been taken in physical presense on permit slip and will be lifted on the same permit by the physical reportingat Sub station with proper time and signature.Note . No shut down given/ lifted on mobile phone. Shut down shall be given / lifted only after physical reporting of electrician at power house(v) All safetyprecaution will be taken by the Contractor/his rep.incase of any physical injury / any mishappning contractor is responsible for all the medical treatmentand compansation to the individual . No extra cost paid to the contractor for the same.(vi) Contractor will provide shut down permit book for taking shut down permit from the JE/ Engr-in-Charge on duty. No extra cost will be paid for the same.(vii) Contractor has to deposit all the stores in advance for attending day to day complaints and late hours complaints. (vii) Tinned copper fuse wire and self adhesive insulation tapes to be used in complaints shall be measured and paid seperately as supply only. 4 Excavation in trenches n .exc 1.5 mtr wide and not exec 1.5 mtr in depth for foundation etc or for laying pipe lines and cables and getting out as in looses/soft soil complete all as specified. 5 Returning filling in including spreading leveling, watering and well ramming in layer not exe. 25 cm in soft/ loose soil, complete all as specified and directed. 6 Removing excavated material to a distance not exc 50m and depositing where directed at a level n.exc 1.5 mtr above the starting point complete all as specified. 7 Supply,laying & fixing double wall corrugated (DWC) pipes made of high density polythyline (HDPE) with all accessories i.e. all type of joints,Sockets,Elbows,bends and End caps as size of DWC pipe is 63mm O/D and 50 mm Inner dia allas specified and directed by Engr in Charge.of fwg sizes. 8 Description all as per srl item No 5.00 here-in-before but of size 76mm outer dia and 63mm inner dia. 9 Description all as per srl item No 5.00 here-in-before but of size 90mm outer dia and 76mm inner dia. 10 M&L for in replacement of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured heavy duty electric power cable 1100 volts with stranded aluminium conductor of size 240 Sqmm 3.5 core laid in trenches or under road complete all as specified and as directed. (Note: Excavation, cable protection work will be measure & paid separately) 11 Description all as per srl item No 8.00 here-in- before but of size 120 Sqmm 3.5 core. 12 Description all as per srl item No 8.00 here-in- before but of size 95 Sqmm 3.5 core. 13 Description all as per srl item No 8.00 here-in- before but of size 50 Sqmm 3.5 core. 14 Description all as per srl item No 8.00 here-in- before but of size 35 Sqmm 3.5 core. 15 Description all as per srl item No 8.00 here-in- before but of size 25 Sqmm 4 core. 16 Description all as per srl item No 8.00 here-in- before but of size 16 Sqmm 4 core. 17 Excavating and relaying cables LT loops near the poles LT Panels transformers, cutting the damages/burnt parts of cable and reconnecting its into positions complete with thimbles, nut bolts, sleaves all as specified and directed by Engineer-in-Charge. 18 Excavating and relaying high tension cables loops near the poles , transformers, cutting the damages/burnt parts of cable and reconnecting its into positions complete with thimbles, nut bolts, sleaves all as specified and directed by Engineer-in-Charge. 19 Replacement ofpin type porcelainwhite, brown or green insulator including one galvanized mild steel spindle,two galvanisediron washers & one galvanised nut 100mm height, 65mm dia for working pressure 1100 volts grade.all as specified and directed by Engr-in charge 20 S & F in shackle type,vitreous Insulator incl one galvanised mild steel spindle, two galvanised iron washerrs and one galvanised iron nut, 100 mm height, 115 mm dia ,suitable for 1100 Volt and as directed by engineer in charge. 21 Supply and spraying anti vegetation chemical liquid of 1ltrs bottle mixed with water (water to be measured seperately) as per direction of Engr in charge 22 Supply and fixing in replacement of disc type insulator, porcelain, vitreous white, brown or green insulators for working pressure 11000 Volts of 145 mm height 255mm dia ball and socket type Single Disc assembly for tension with tension clamp for conductors including bolts, nuts & washers. 23 Supply & fixing in replacementPin typetype polymer/ porcelain insulator including onegalvanised mild steel straps, washers and nut,size 150mm height and 150mm dia suitable for 11000 Volts including removal of existing insulators complete all as specified and directed. 24 Supply and fixing in replacement ofmale female contacts ofgang operative switchmade out of brass and rated capacity 200 amps ,make matching withthe existing switchcomplete all as specified and directed . 25 Supply and fixingin replacement of copper ribbon suitable for 200 amps rated capacity gang operative switch, 45 CM long complete all as specified and directed . 26 M&L for CRC 226 (500 ml) grease/Liquied suitable for VCB mechanism and air break switchescomplete all as specified and as directed by Engr-in-Charge 27 S&F in replacement air break switch insulator, 200 Amp, 11 kv complete all as specified and as directed. 28 Material and Labour straight through joint kit ofheats shrinkable suitable for120 sqmm to 185 sqmm HT3 core 11000 volts XLPE cable type complete all as specified and directed. 29 Material and Labour in replacement for Out door End temination kit ofheats shrinkable suitable for95 sqmm to 120 sqmm HT3 core 11000 volts XLPE cable type complete all as specified and directed. 30 Taking out carefully manually by excavation of existing HT cable of any sizeupto transfromer with loops and relaying with old retrieved cable cover complete the same after repair of cutting the damages / burnt parts of cable and reconnecting its into originalpositions complete with cable joints all as specified and directed by Engineer-in-Charge.Note:-(i) Unit rate shall include in excavation and returning filling. 31 Taking out carefully manually by excavation / Pulling of cable with rope of existing LT cable of size 10 Sqmm to 95 Sqmm with loops and relaying with existing DWC piperepair/ cutting the damages / burnt parts of cable and reconnecting into originalpositions complete with cable joints all as specified and directed by Engineer-in-Charge.Note:-(i)LT Cable Joint will bemeasured and paid sepearetly. (ii) Unit rate shall include for excavation and returning filling. 32 Taking out carefully manually by excavation / Pulling of cable with rope of existing LT cable of size 120 Sqmm to 240 Sqmm with loops and relaying with existing DWC piperepair/ cutting the damages / burnt parts of cable and reconnecting into originalpositions complete with cable joints all as specified and directed by Engineer-in-Charge.Note:-(i)LT Cable Joint will bemeasured and paid sepearetly. (ii) Unit rate shall include for excavation and returning filling. 33 Labour for cleaning away all grass vegetation, scaling shrubs bushes under growth roots and trees not exceeding 30cm girth and removing rubbish aroung LT Panel, transformer, sub stations, LT Poles, under over head lines complete all as specified and as directed. 34 S&F in replacement for heat shrinkable straight through joint for LT PVC/XLPE insulated armoured cable of size50 Sqmm 3.5/4 core complete all as specified and as directed. 35 Description all as per srl item No 32.00 above but LT cable size of 95 to 120 Sqmm 36 Description all as per srl item No 32.00 above but LT cable size of 150 to 185 sqmm 37 Description all as per srl item No 32.00 above but LT cable size of 240 to 300 sqmm 38 Supply and replacementHT bush rod suitable for indoor / outdoor type 315 to 630 KVA transformer complete with brass stud, brass nuts, brass cup and packing gasket complete all as spd and directed. 39 Description all as per Srl item No 36.00 here-in-before but suitable for 100 to 250 KVA transformer. 40 Supply and Fix high grade PVC LT overhead phase to phase line spacer suitable for4 lines/wires, suitable for verticale and horizontal line complete all as specified and as directed. 41 S&F in replacement HT Jumpers wire not less than 95 Sqmm HT single core from top disc insulator to GOD and disc to disc in any lenth with complete nuts & thimbles all as required at site. 42 M&L for in replacement of aluminium cable lugs/thimbles long barrel type ofsuitable for XLPE armoured heavy duty electric power cable 1100 voltsaluminium conductor of size 25 Sqmm 3.5/4 core bolt dia M14 including jointing/crimping and testing complete all as specified and as directed. 43 Description all as per srl item No 40.00 here-in- before but of size 35 Sqmm 3.5 core. 44 Description all as per srl item No 40.00 here-in- before but of size 50 Sqmm 3.5 core. 45 Description all as per srl item No 40.00 here-in- before but of size 70Sqmm 3.5 core and bolt dia M16. 46 Description all as per srl item No 40.00 here-in- before but of size 95 Sqmm 3.5 core and bolt dia M16. 47 Description all as per srl item No 40.00 here-in- before but of size 120 Sqmm 3.5 core and bolt dia M16. 48 Description all as per srl item No 40.00 here-in- before but of size 150Sqmm 3.5 core and bolt dia M20. 49 Description all as per srl item No 40.00here-in- before but of size 185 Sqmm 3.5 core and bolt dia M20. 50 Description all as per srl item No 40.00 here-in- before but of size300 Sqmm 3.5 core and bolt dia M20. 51 M&L cross arms bracings supports clamps and back plates fabricated from structural steel sections including nut bolts washers welding bending cold and hot drilling holes for bolts in any shape or size as inticate or directed and inclusive of one primer coat one under coat and one finishing coat of aluminium paint complete all as specified and directed 52 Supply and laying or fixingin replacement 1100 Volts grade heavy duty cable with PVC insulated aluminium standard conductor served with an inner sheathing of PVC tape and over all PVC Sheathed in service connections , one twin core 10 Sqmm cable standard conductor cable flat or circular all as specified and directed by Engineer- in- Charge. 53 Material and labour for ACSR conductor any size drawn straight horizontal on over head lines on existing poles including binding with insulators weight of conductor shall be measured straight horizontal distance between centre of two adjacent HT/LT poles and calculating weight of conductor of size length by adding 3% extra for sag jointingjumpers etc complete all as specified and directed 54 M&L for earthing complete with galvanized iron or steel plate electrode 600 mm x 600 mm x 6.00 mm thick buried directly in ground vertically in pit of depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides with mixture of charcoal andcommon salt in alternate layers and electrode connected to galvanized iron strip 32 x 6 mm dia as earthing lead by means of GI bolts, nuts, check nuts and washers, earth strip protect0ed by galvanized steel pipe 40 mm bore (light grade) connected to machinery/ equipment all as shown in electrical plate No. 3 of SSR-2010 Part I and including necessary excavation and earth work in any type of soil, 20mm bore light grade GI pipe for watering, funnel, wire mesh, PCC (1:3:6) type C-1 chamber, MS cover of thickness 5mm openable type and having suitable locking arrangementand MS frame of suitable size made of angle iron 50 x 50 x 60 mm, complete all as specified. Note: (i) The unit rate includes earth lead and protection pipe up to maximum 7.5 metre from earth plate to earth point/test point. (ii) Earth pit shall be constructed minimum 0.5 metre away from earth. 55 S & F in replacement of MCCB four pole 100 Amps with breaking capacity 16KA , 415 Volts, fixed thermal & magnetic release including making all incoming/ outgoing connections fixed & MCCB matching with the existing slots complete all as specified and directed by Engineer in Charge. 56 Description all as per srl item No 53.00 but160 Amps with breaking capacity 25 KA. 57 S & F in replacement of MCCB four pole 250 Amps with breaking capacity 36 KA , 415 Volts, adjustable thermal & fixed magnetic release Ics=100% including making all incoming/ outgoing connections fixed & MCCB matching with the existing slots complete all as specified and directed by Engineer in Charge. 58 Description all as per srl item No 55.00 but315 Amps with breaking capacity 36 KA. 59 S & F in replacement of MCCB four pole 400 Amps with breaking capacity 35/36 KA , 415 Volts, Microprocessor releaseIcs=100% inbuilt adjustable overload, short circuit, ground fault including, spreader terminal including all incoming/ outgoing connections fixed & MCCB matching with the existing slots complete all as specified and directed by Engineer in Charge. 60 Description all as per srl item No 57.00 but600 Amps with breaking capacity 36 KA. 61 M&L for repairing the existing LT panel/Feeder Piller Box/APFC Panel any type or size by taking proper shutdown for power house and disconnecting and re-connecting cables connection both in coming and outgoing using appropriate size of thimbles, making proper welding, drilling for smooth functioning of panel/feeder door, replacement of unserviceable aluminium bus bar of suitable capacity/size as per existing including bakelite insulators, cable glands, terminals, base plate, necessary nuts, bolts & washers, locking arrangement complete all as specified and directed.Note 1.Necessary accessories like MCCB/MCB, CT coil, ammeter, voltmeter, indication lamp, selector switch etc shall be measured and paid seperately as supply & fixing under respctive item.2.Necessary items like nut, bolt washer, thimbles, hinges, locking arrangement welding machine/tools as required and same shall be deemed to be included in the item rate quoted 62 Supply and laying GI steel tubing, 80mm bore, light grade with all fittings, laid in trenches / under roads / along pole / wallfor protection ofCable / GI wire / GI strip etc complete all as specified and directed. 63 Supply and laying GI steel tubing, 50mm bore, light grade with all fittings, laid in trenches / under roads / along pole / wallfor protection ofCable / GI wire / GI strip etc complete all as specified and directed. 64 Supply onlytinned copper fuse wire 22 SWG to 35 SWG 5 Ampere to 24 Ampere (14 sizes ),each roll weight from 125 to 150 gm , sutable for fuse wire complete all as specified and as directed. 65 Supply only medium voltage fire resistant high quality PVC self adhesive electrical insulaiontape (Red, Yellow, Blue & Black) high quality size minimum 18mm width and 07 mtr long complete use in respect of Item No 01 above complete all as specified & directed. 66 Supply onlyhigh voltage fire resistant, flame retardantself adhesive electrical insulaiontape suitble for 11KV (RYB), high quality self melgamate size minimum 38mm width and 09 mtrlength use inrsspect of Item No 01 above complete all as specified & directed by Engr-in-charge. 67 Supply and fill up transformer oiltopping uphaving dielectric strength not less than 60 KV at 4 mm gap conforming to IS complete all as specified and directed. 68 S&F in replacement of ON load change over switch with sheet metal enclosure, 415 V, 4 pole of capacity 160 Amps including connecting up incoming and outgoing cables with suitable lugs and testing complete all as specified & directed. Make:Havells/Standard/Indiasian/Schnider/L&T 69 M&L for replacement of Existing Unserviceable LT feeder pillar box out door type with new supply, installation, commisioning and testing LT feeder pillar box out door typedouble door and single shutter front open including locking arrangement system made out of MS sheet of 3.15 mm CRCA sheet of size 0.6x0.6x0.3 mtr and double door,canopy,dust proof, bottom cable entry plate and gland for cable size150/120/95/70/50/25/16/10 sqmm 3.5 core suitableMS angle iron 40x40x5 mm with aluminium busbar size 600Ampssystemmounted on hygroscopic insulators bus bar includingsuitable nut, Bolt and Washer(16 Nos) , & including powder coated paintwithand providing necessary foundation/plateform of the feeder pillar height 1.5 feet from groundwith PCC 1:2:4 type B2 including provision of for incomong and outgoing cable gland, thimbling for old / new cables as per site requirement and proper finshing as per existing surface complete all as specified and directed by Engr- in- Charge. Note: Drawing for LT feeder piller box shall be got approved by GE before fabrication. 70 Material and labour for locating the fault in Servo voltage stablizer of Capacity 400 to 500 KVA any make of 440 Volts, repair/ replacement of defected items, drying moisture from Voltage stablizer and top up of Oil complete of system and restand the elect supply complete all as specified and as directed.(FCAB Sub Stn)Note :- (i) All tools and plant including blower/ gas cylinder, spray for cleaning bus bar , spray for bus bar insulation , cleaning clothes , emergency lighting arrange in power house for repair work and other equipment will be arranged by the contractor with no extra cost paid to contractor.(ii) One Voltage stablizer will be catered as on Job (iii) Contractor shall deposit / Procure all the material in advance to avoid any late night fault/ after market hours / non availability of material in market. The elect supply shall be restore within 8-12 hours from the time of tripping / fault in day or night in the FCAB Sub/stn, failing this a panelty of Rs 2000/- per complaint / fault will be imposed on the contractor from contractor dues.(iv) Minimun one Voltage stablizershall be produce to contractor for restand/ repair for one visit. Contractor will not demand all stablizer repair in one visit. Visit and Repair charges of electrician and helper are included in the quoted rate. no extra charges paid to contractor.(V) Volt meter,Amp meter,DC/AC wiring kit,Control card and any type indicator replace measure and paid in quoted rate no extra charge paid to contractor. (vi) Voltage stablizer Oil replace measure and paid saperately 71 Supply & fixing earth strip continuity conductor on main earthing lead fixed toPanel/pole or buried in ground or at any other situation for loop earthing extra as required (beyond 7.5 M) of GI Strip 25x3 mmall as specified 72 M&L for Boring of holes under road, pavement, hard standing by trenchless ultra sound technology/mannual all as per site requirment complete all as specified & directed.