Lte For Store Rooms And Repairs Of Existing Stores At Cycle Velodrome At Sai Ns Nis Patiala. -Supplying chemical emulsion in sealed containers including delivery as specified. 2 Chlorpyriphos emulsifiable concentrate of 20% 3 Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : 4 Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: 5 With Chlorpyriphos E.C. 20% with 1% concentration 6 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 7 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) 8 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: 9 Cement mortar 1:4 (1 cement : 4 coarse sand) 10 12 mm cement plaster of mix : 11 Cement mortar 1:4 (1 cement : 4 coarse sand) 12 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wallsurface to prepare the surface even and smooth complete. 13 Two coats 14 Painting with synthetic enamel paint of approved brand andmanufacture to give an even shade : 15 Two or more coats on new work 16 12 mm cement plaster of mix : 17 Cement mortar 1:4 (1 cement : 4 coarse sand) 18 Distempering with 1st quality acrylic distemper, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats whereverrequired, to achieve even shade and colour. 19 Two Coats 20 Renewing glass panes, with putty and nails wherever necessaryincluding racking out the old putty: 21 Float glass panes of nominal thickness 4 mm(weight not less than 10kg/sqm) 22 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : 23 For shutters of doors, windows & ventilators includingproviding and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) 24 Powder coated aluminium (minimum thickness of powder coating 50 micron) 25 Providing and Fixing ACP sheet for Door of approved quality with the spectification confirming to IS complete as per direction of Engineer in Charge. 26 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 27 Thermo-Mechanically Treated bars of grade Fe-500D or more. 28 Electrical Work 29 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 30 Group A 31 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 32 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 33 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 34 Single pole 35 Triple pole and neutral 36 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 37 32 mm 38 providing and fixing following capacity TP&N Disconnector fuse switch unit inside the existing panel board with ISI marked marked HRC fuses including drilling holes in cubical panel,making connections,etc.as required. 39 64 A TP&N 40 Providing and fixing following rating,20 W LED Light complete with connections,testing and commissioning etc. as required. 41 Providing and fixing 300 mm exhaust with complete installation and commissioning 42 providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubical panel,making connections,etc.as required. 43 63 A TP&N 44 Supplying and Fixing Following way Single Pole and neutral,sheet steel,MCB distribution Board, 240V on surface/recess,complete with tinned copper bus bar,neutral bus bar,din bar,interconnections,powder painted including earthing etc.as required.(But without MCB/RCCB/Isolator) 45 6 way , double door => Limited