}

Tender For Certain Mw And Rw At Mil Stn Sri Ganganagar, ganganagar-Rajasthan

Statutory Bodies & Commissions/Committees has published Tender For Certain Mw And Rw At Mil Stn Sri Ganganagar. Submission Date for this Tender is 28-09-2024. Road Repair Tenders in ganganagar Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

45128819
Corrigendum : Tender For Certain Mw And Rw At Mil Stn Sri Ganganagar
Open Tender
Indian
Rajasthan
Ganganagar
28-09-2024

Tender Details

Tender For Certain Mw And Rw At Mil Stn Sri Ganganagar; 1 Surface dressing exc (not exceeding) 15 cm deep and getting out soft/loose soil complete all specified and directed by Engineer-in-Charge 2 Excavation in trenches not exceeding 1.5 Mtr wide and not exceeding 1.50 Mtr in depth for foundation, etc., not exceeding 10 Sqm on plan in soft /loose soil; & getting out complete all as specified and directed by Engineer - in -Charge. 3 M&L for PCCas in foundation type D-2 1:4:8 (40mm graded stone aggregate) complete all as specified and directed by Engineer - in -Charge. 4 M&L for Reinforced Cement concrete (design mix) M-25 using 20mm graded stone aggregate in foundations, footings, plinth beams etc complete all as specified and directed by Engineer - in -Charge. 5 M&L for Reinforced Cement concrete (design mix) M-25 in columns, pillars, piers, posts and struts complete all as specified and directed by Engineer - in -Charge. 6 M&L Reinforced Cement concrete (nominal mix) 20mm graded stone aggregate inslabs supported on walls, beams and columns , in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed by Engineer - in -Charge. 7 M&L MS TMTbars as in reinforcement 10 mm dia and over cut to length bent to shape required incl cranking bending spirally for hooping for cols, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90 mm dia using TMT bars complete all as specified and directed by Engineer - in -Charge. 8 M/L MS TMT bar 8 mm dia cut in shape length incl cranking bending etc and binding with and incl MS wire not less than 0.9 mm complete all as specified and directed by Engineer - in -Charge. 9 Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams;and similar work; vertical or to better for flatrough finished surface of concrete etc complete all as specified and directed by Engineer - in -Charge. 10 Formwork to sides of pillars, posts, struts, piers, columns and stanchions for square, rectangular or polygonal rough finished surface complete all as specified and directed by Engineer - in -Charge. 11 M&L for Damp Proof course, 40mm thick in PCC 1:2:4 type B-0 (using 12.5 mm graded crushed stone aggregate to horizontal or vertical surfaces including mixed with water proofing compound as per manufacture instructions including necessary form work complete all as specified and directed by Engineer - in -Charge.NOTE : Supply only WPC to be measured and paid separately. 12 Supply only integral water proofing compound ISI marked complete all as specified and directed by Engineer - in -Charge. 13 M&L brick work with Fly Ash bricks straight or curved on plan exceeding 6.0m mean radius built in cement mortar 1:6 all as specified and directed by Engineer – in – Charge. 14 M&L brick work with Fly Ash old size bricks straight or curved on plan exceeding 6.0m mean radius built in cement mortar 1:6 all as specified and directed by Engineer – in – Charge. 15 M&L brick work with Fly Ash bricks straight or curved on plan exceeding 6.0m mean radius in half brick thick walls built in cement mortar 1:6 all as specified and directed by Engir – in – Charge. 16 M&L, 15mm thick rendering/plastering 15 mm thick on any face of brick wall or concrete surface consisting in two layers i.e. First laye 10 mm thick in cement mortar (1:4) and second (top layer) layer 5 mm thick in cment mortar (1:4) including mixing of liquid WPC in mortar @ asper manufacturer instruciton per bag of cment of 50 Kg, finisied even and smooth without using extra cement complet all as specified and as directed by the Engineer in charge (Note WPC shall be measured & paid separately as supply only) in CM 1:4 on fair faces of brick or concrete wall surfaces finished even and smooth without using extra cement complete all as specified and directed by Engr-in-charge. 17 M&L rendering 15mm thickin CM 1:6 on faces of brick work or conc work finished even & smooth w/o using extra cement complete all as specified and directed by Engr-in-charge. 18 M&L 5mm thick rendering in CM 1:3 to brick / concretesurface of ceilling surfaces finished even & smooth without using extra cement complete all as specified and directed by Engr - in -Charge. 19 M & L Preparation of new plastered surfaces of wall and applying two coats of cement base paint laid over & including 3 mm thick wall putty over one coat of alkali resistantprimer complete all as specified and directed by Engr - in -Charge. 20 M&L for preparation ofnewly plastered surface of wall any description and applying twocoats of oil emulsion distemper laid over & including 3 mm thick wall putty over a coat of chalk whiting layer on plastered surfaces preparatory to distempering complete all as specified and directed by Engr - in -Charge. 21 M&L two coat of cement base paint over chalk whitening wash to new plastered wall surface incl preparation of surface completeall as specified and directed by Engr-in-charge. 22 M&L for three coat of white wash on ceiling on new plastered surface including prepration all as specified and directed by Engr-in-charge. 23 M&L for painting two coats of synthetic enamel paint over a coat of red oxide primer on steel surfaces complete all as specified and directed by Engr-in-charge. 24 M&L hardcore of gauge n exc 63 mm, (broken stone or boulders) deposited, spread and levelled in layers n exc 15 cm thick, watered and rammed to a true surface all as specified and directed by Engr-in-charge.(Broken bricks) 25 M&L 75 mm thick PCC (1:4:8) type D-2 (using 40 mm graded stone aggregate) as in sub base flooring complete all as specified and directed by Engineer - in -Charge. 26 M&L for Virified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over & including 15mm thick screed in CM 1:6 complete all as specified and directed by Engineer - in -Charge. 27 M&L 450x300 x7/600x300x7 mm thick glazed ceramic coloured tiles as in vertical sufaces such as skirting or dado set & jointed in neat cement slurry & pointed in coloured cement to match the shade of tiles and laid over & including 10mm thick backing coat in CM 1:4 complete all as specified and directed by Engineer - in -Charge. 28 M&L providing 75 mm thick cement concrete type 1:3:6 (20 mm graded) C-2 as in Plinth protection finished even & smooth w/o using extra cement complete all as specified and directed by Engineer - in -Charge. 29 S&F factory made fiber glass reinforced plastic (FRP) Door frames of three legged of cross section 90mmx45mm having single rebate of 32mmx15mm to receive shutter of 30mm thickness. The laminate door frame molded with fire retardant grade unsaturated polyster resin and chopped mat. door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. the frame shall be covered with fiberglass from all sides. M S stay shall be provided at the bottom to steady the frame complete all as specified and directed by Engineer - in -Charge. 30 S&F factory made 30mm thick fiber glass reinforced plastic (FRP paneled DoorShitter ofrequired colour and approved brand and manufacture made with fire-retardant grade unsaturated polyster resin. Moulded to 3mm thick FRP laminate for forming places for fixing of fittings cast monolithically with 5mm thick FRP laminate for panels and conforming to IS 14856-2000 including 03 x 100mm longbutt hinges, heavyweight, cold rolled mildsteel, 150 mm long aluminium handle cast type anodised, 01 x aluminium anodised barrel tower bolts of extruded section 150mm long complete all as specified and directed by Engineer - in -Charge. 31 M&L anodised aluminium frames for doors, windows withone or moe rebates including jointing cleats for fixing etc.including power coating minimum thickness of power coating shall be 50 micron as per the specification) complete all as specified and directed by Engineer - in -Charge. 32 S&F powder coated aluminiumwindowsand ventilator shutters,side hung type, without sash bars aluminium saction weighing 0.55 kg/RM including necessary jointing cleats, glazing clips, rubber packing, powder coated aluminium snap beading, screws, powder coated aluminium fitting such as peg stay 150mm long (1 no) hinges type B21 100 mm long (2 No) suitable handle (1No) including aluminium grill and wire mesh complete all as specified and directed by Engineer - in -Charge. 33 S & F for 5.5mm thick sheet glass(tinted),selected quality and glazing with necessory arrangement in square exc 0.5 sq. m in each pane complete all as specified and directed by Engineer - in -Charge. 34 S&F Aluminum alloy wire cloth , 0.45 mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples complete all as specified and directed by Engineer-in- charge. 35 S & F rotational moulded polythylene water storage tank (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part -I (1000 Ltrs) capacity complete all as specified and directed by Engineer - in -Charge. (Note PVC tank shall be ISI marked & having two layer) 36 Supply and fixingball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed for bore dia of pipe 20mm complete all as specified and directed by Engineer - in -Charge. 37 S&F steel water tubing galvanised 20mm bore, medium grade with all fittings fixed to wall and ceiling or in floor complete all as specified and directed by Engineer - in -Charge. 38 S&F steel water tubing galvanised 15 mm bore, medium grade with all fittings fixed to wall and ceiling or in floor complete all as specified and directed by Engineer - in -Charge. 39 S&F, CP 15mm bore bib taps cast copper alloy with crutch or butterfly handles, screwed down complete all as specified and directed by Engineer - in -Charge. 40 Supply and fix CP stop valves cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends Bore of pipe in 20mm,complete all as specified and directed by Engr-in-charge. 41 Supply and fix, CPstop valves, cast copper alloy 15 mm bore screwed down high pressure with crutch or butter fly handle for iron pipe or for union and complete all as specified and directed by Engineer - in -Charge. 42 Supply and fix CP Angle stop valves of any type concealed/exposed, cast copper alloy 15 mm bore screwed down high pressure with crutch or butter fly handle for iron pipe or for union and complete all as specified and directed by Engineer - in -Charge. 43 S&F 20mm bore ball brass valve high pressure, with polythelene float and flynut complete, screwed to iron pipe complete all as specified and directed by Engineer - in -Charge. 44 Supply and fixCounter top/counter sunk vitreous china wash hand basin white flat back of size 550mm X 400mm, fixed on coloured granite and fixed to wall, inlcuding of 15mm size pillar tap, cast copper alloy, with capstan head, chromium plated, screwed down high pressure, with or without letter Hot or cold with long scrwed shanks and fly nuts, 32mm dia brass chromium plated waste fittings 450mm long, stainless steel bottle trap and 40mm dia waste pipe complete all as specified and directed by Engineer in Charge 45 S&F PVC Connection 15mm size with PTMT nuts of length 450 mm complete all as specified and directed by Engineer - in -Charge. 46 S&F vitreous china squatting pan ORISSA pattern white, of size 580x440mmwith integral foot rest, CI P trap etccomplete all as specified and directed by Engineer - in -Charge. 47 S&F vitreous China wash down water closet pan (pedestal pattern) white complete, including white seat cover with hinging arrangement, (excluding fixing bolts, flushing cistern and flush pipe) all as specified and directed (10 ltr capacity) all as specified and directed by Engr-in-charge. 48 S&F PVC valveless syphonic action type flushing cistern low level white with inlet ball valve float and handle including brackts all as specified and directed (10 ltr capacity) all as specified and directed by Engr-in-charge. 49 M & L granite (of any type)work16 to 20 mm thick(table rubbedand polished) in cooking platforms and like in cement mortar 1:4including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including 15mm of screed bed in CM 1:6. complete all as specified and directed by Engineer - in -Charge. 50 S&F 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed by Engineer - in -Charge. 51 S&F Tubular towel rail, 20 mm dia. D type, 60 cm long between flanges Brass Chromium plated complete all as specified and directed by Engineer - in -Charge. 52 S&F Towel Ring of aluminium fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 90gms)complete all as specified and directed by Engineer - in -Charge. 53 S&F stainless steel CP Health faucet fixing in pipe etc. complete all as specified and directed by Engineer - in -Charge. 54 S&FUrinal partitions slabs of 15 mm thick toughned glass terminating about 40cm above floor line, complete all as specified and directed by Engineer - in -Charge. 55 S&F Glass shelf assembly fixed in repair complete all as specified and directed by Engineer - in -Charge. 56 S&F, 100 mm dia (spun) cast iron soil waste pipe and vent pipes in any length with or without ears with cement joints laid in trenches or in floors all as specified and directed by Engr-in-charge. 57 M&L for 75mm dia (spun)cast iron sand cast waste and vent pipes in any length with or without ears with cement jointed fixed to wall complete 58 M&L for 100mm dia cast iron Bends complete all as specified and directed by Engineer - in -Charge. 59 M&L for 75mm dia cast iron Bends complete all as specified and directed by Engineer - in -Charge. 60 S&F Vitreous China Urinals, bowl type ( back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2 , securing urinal to plugs with and including 60 mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. ( Exclusive of fixing supply pipe to flushing cistern , trap and waste pipe) including CP Urinal spreaderfor fixing with 15mm diapipe.(Minimum weight 60gms) complete all as specified and directed by Engineer - in -Charge. 61 S&Fgratings 100 mm dia of PTMTfixed in repairs.(Minimumweight25 gms ) complete all as specified and directed by Engineer - in -Charge. 62 M&L for PCC 1:3:6 type C-2 using 40mm graded stone aggregates concrete bed to drain pipes for 100mm boreincluding packing under, and haunching against the sides of pipes after they are laid andall as specified and directed by Engr-in-charge 63 M&L for concrete bed to drain pipes for 150mm boreincluding packing under, and haunching against the sides of pipes after they are laid andall as specified and directed by Engr-in-charge 64 M&L 100mm bore (internal dia) salt glazed stone ware drain pipe, grade ‘A’, laid on concrete bed to required slope, jointed and tested complete all as specified and directed by Engineer - in -Charge. (concrete bed & packing under hanching shall be measured and paid for separately). 65 M&L 150mm bore (internal dia) salt glazed stone ware drain pipe, grade ‘A’, laid on concrete bed to required slope, jointed and tested complete all as specified and directed by Engineer - in -Charge.(concrete bed shall be measured and paid for separately). 66 M&L pre-cast cover slab for 65mm thicknesstype B1 (1:2:4) using 20mm graded stone aggregate complete all as specified and directed by Engineer - in -Charge. 67 M&L Cutting for 150 mm bore pipe into existing manhole for connecting new drain making good to pipe and rendering cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished and reforming benching as required complete all as specified and directed by Engineer-in-charge. 68 S & F Cast iron floor trap 75mm dia of outlet with grating including jointing to waste pipe fixed in cement concrete type B-1(1:2:4) complete all as specified and directed by Engineer - in -Charge. 69 S&F 100 mm bore cast iron Traps ‘P’ or ‘S’complete all as specified and directed by Engineer - in -Charge. 70 Returning, filling in, including spreading, leveling, watering and well ramming in soft/loose soil in layer not exceeding 25 cm thick complete all as specified and directed by Engineer - in -Charge. 71 Removal of excavated material to a distance not exceeding 50m and deposited where directed at level not exceeding 1.5m above the starting point complete all as specified and directed by Engineer - in -Charge. 72 Excavtion in soft/loose soil, PCC bed, brick work in manhole, laying ofSGSW pipe RCC NP3 150 mm diameter Pipes laid on150 mm thick bed with excavation in any type of soil, including manholes/drop manhole of standard size made of Brick masonry/ RCC/Precast RCC with SFRC ventilating cover and frame. Includes all items and activities to execute and make sewer line functional., return fillin complete all as specified and directed by Engineer - in -Charge. 73 M&L for construction ofSeptic tank (10 to 25 user),RCC Septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 type D-2 using 40mm graded stone aggregate below foundation, RCC M-30 Design Mix in Walls , Base Slab , Baffle walls and Roof Slab including beams etc with Vent shaft , manhole openings with cover connection etc., complete with effective depth of 1.5 metre and overall depth of 3 metre for complete all as specified and directed by Engineer - in -Charge. 74 M&L for construction of Soakage well, excavation, in any type of soil, foundation in PCC 1:3:6, type C-2 using 40mm graded stone aggregate walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 1.8 M dia X 4.5 M effective depth complete all as specified and directed by Engineer - in -Charge. 75 Demolition of RCC of any descrition such as Kitchen chimney, chajja, shelves, OHT Tanks. or in similar work etc and in any position not other wise specially provided for complete all as specified and directed by Engineer in Charge (reinforcement cut as required to facilitate demolition) complete all as specified and directed by Engineer-in-charge 76 M&L for reinforced cement concrete type B1 1:2:4 (20 mm graded aggregate) as in slab supported on walls, beam and column in floors, roofs ,landings, balconies, deck slab, parapet walls and in shelves and etc and setting in mortar complete with joints to match complete all as specified and directed by engr in charge 77 Formwork to sides and soffits of floor or roof beams, beam haunch ings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc. complete all as specified and directed by Engr in charge 78 Dismantling of brick work or stone/boulder masonry built in cement mortar including all quoins, arches , pillars etc but excluding ashlar facings, dressed stone work and precast concrete articles complete all as specified and directed by Engr in charge 79 M&L brick work with sub class B bricks straight or curved on plan exceeding 6 mtr mean radius in cm 1:6 etc complete all as specified and directed by Engineer - in -Charge. 80 Dismantling of brick tiles and mud phuska or terracing tiles single layer on roofincludingmud phuska also taking down existing APP membrane & disposal of retrieved material upto a distance n.exc 100m where directed, complete all as specified and directed by Engr in charge 81 M&L for Roof treatment to RCC roofas follows :- (a) Cleaning the roof surfaces thoroughly using wire brushes to remove sharp projections,cleaning joints,washing,drying and removing all dirt/dust to receive concrete padding/ plaster etc complete all as specified and directed by Engineer - in -Charge. (b) Providing 15 mm thick screed bed or bedding layer of cement mortar (1:4)with WPC , finished even and smooth without using extra cement.(c) Providing one coat of approved bituminous primer @ 100 gms per sqm, over dried plastered surface. (d) Laying 3 mm thick APP based polymeric membrane,minimum weighing 3 Kg/Sqm reinforced withnon woven polyster fabric (weight not less than 150 gms/Sqm) by torch application. The overlapping while torching shall be 75 mm on longitudinal direction and 100 mm on the transverse direction complete all as specified and directed by Engineer-in-Charge.Makes:-STP, Dr Fixit, SikaNotes: (i) All joints and change in directions should be covered with cement mortar (1:3) mixed with SBR latex @ 200 ml/bag of cement/ as per site requirement and cured well before laying membrane by torching.(ii) All angles and abuttments should be sealed well with extra care to ensure full bondage. (iii) Water proofing treatment shall be got carried out by approved authorised applicator of manufacturer only.The name of firm shall be got approved from GE before carrying out the work. (iv) The independent testing of membrane for technical parameters given in particular specificationsshall be carried out from Govt approved labs having fascilities for testing of membrane. (v) The guarantee of treatment shall be for minimum 10 yearsreckoned from date of completion of whole work 82 S&F heat resistance tiles ofsize 300x300x8-10mm thick on roof slab of any colour approved over and laid including 15mm thick in CM 1:4.Techinical specification of roof tilescomplete all as specified and directed by Engineer - in -Charge. 83 M&L PCC 1:2:4,type B1 using 20 mm graded stone aggregate as in roof/roof kerbs / benching / coved fillets etc rounded or chamfered on edges, complete all as specified and directed by Engineer - in -Charge. 84 Taking down cement plaster or cement lime plaster on PCC/stone surface/brick surfaces including raking out joints hacking for key scrubbing down with water etc complete all as specified and directed by Engineer - in -Charge. 85 M&L for preparation of old surface including brooming down or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and removing all dirt and dust by watering making surface even and smooth and then applying two coats of cement base paint over over3 mm thick wall putty well prepared old decorated plastered surface etc all as specified and directed by Engineer - in -Charge. 86 M & L for preparation of old decorated wall surfacesby brooming down or steel wire brushing,scrapping down smoke soot,moulds,moss and efflorescent salts and trading oil and greasy spotsand then applying two coat of oil bounddistemper over3 mm thick wall puttycomplete all as specified and directed by Engineer - in -Charge. 87 M & L forold decorated ceiling surfacesby brooming down or steel wire brushing,scrapping down smoke soot,moulds,moss and efflorescent salts and trading oil and greasy spotsandthen applyingtwo coats of white washcomplete all as specified and directed by Engineer - in -Charge. 88 Taking up or down GI tubing 15 mm bore pipe including cleaning for re-fixing or removal to store complete all as specified and directed by Engineer - in -Charge. 89 Ditto- but refixing 15 mm dia ,old steel tubing and connections in new or old possition (wall,ceiling and floors etc) complete all as specified and directed by Engineer - in -Charge. 90 Taking up or down GI tubing 20 mm bore pipe including cleaning for re-fixing or removal to store complete all as specified and directed by Engineer - in -Charge. 91 Ditto- but refixing 20 mm dia ,old steel tubing and connections in new or old possition (wall,ceiling and floors etc) complete all as specified and directed by Engineer - in -Charge. 92 Dismantling PVC water tanks and removing for capacity exceedin 250 litres & not exceeding 500 litres etc., complete all as specified and directed by Engineer - in -Charge. 93 S&F gun metal globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed of 20 mm bore,all as specified and as approved by Engineer-in-Charge. 94 Demolition and breaking up or taking down PVC/AC/CI/SSW 100mm bore pipe drain pipes,set in cement mortar including PCC haunching and bedding, all as specified and as approved by Engineer-in-Charge. 95 S&F 110mm bore PVC (SWR) pipessingle socketed in any length with rubber ring joints fixed to wall complete all as specified and as approved by Engineer-in-Charge. 96 S&F 110mm bore PVC (SWR) bend, any radius with access door complete all as specified and as approved by Engineer-in-Charge. 97 S&F 110mm bore PVC (SWR) vent cowl complete all as specified and as approved by Engineer-in-Charge. 98 S & F Stack clamps out of 50mm by 5 mm flat iron and 16mm dia round iron stays for 100mm bore of pipe, including bolts and nuts and securing ends of stays to wall or roof etccomplete all as specified and directed by Engineer - in -Charge. 99 M&L providingreinfoced cement concrete (nominal mix) in cement concrete 1:2:4 Type B1(20mm graded aggregate)as chajjasetcand similar workcomplete all as specified and directed by Engineer-in-Charge.(Note : The rate quoted shall be deemed to include use and waste of necessary form work) complete all as specified and directed by Engineer - in -Charge. 100 M&L 9 mm thick, 5 ply Veneered decorative plywood, grade I (with BWR resin) decorative veneers on both facesas in cup board shutter/ shelves/ cabinet including shutter frame etc, complete all as specified and directed by Engineer - in -Charge. 101 S&F 25 mm size magnetic catches with Plastic body and striking plate including letting in and fixed complete all as specified and directed by Engineer-in-Charge. 102 S & F Stainless steel fancy type 200 mm handle complete all as specified and directed by Engr In charge 103 S & FTelescopic Ball bearingChannelchromium plated of size 500 mm (when closed) fix to kitchen basket complete all as specified and directed by Engr In charge 104 S& F Auto Closing Concealed Hinges for Half Overlay Doors with 95 Degree Opening Angle complete all as specified and directed by Engr in charge 105 S & F Continuous (piano) hinges, (width of flap 40mm when open)mild steel, bright finish or electro galvanisedcomplete all as specified and directed by Engr In charge 106 S & F Machine cut kota stone slab flooring 18-20mm thick (minimum size 55cms x 55cms) over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing, mirror polishing including 15mm of screed bed in CM 1:6 complete all as specified and directed by Engr In charge 107 M & L machine cut kota stone slabs as in vertical surfces such as risers of steps 18-20mm thickover cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing, mirror polishing also moulding edges laid, over & including 10mm of backing coat in CM 1:4, complete all as specified and directed by Engineer-in-Charge. 108 Excavating post holes (or similar holes) each n.exc. 0.5 cum getting out returning filling, in and ramming earth with earth around in layers not exc. 25 cm includingwatering and removing surplus soil to a distance n.exc. 50m and making good surface in soft loose soil complete all as specified and directedbyEndineer -in -Charge. 109 M&L PCC 1:3:6 (40mm graded stone aggregate) type C2,in foundation of posts and strutscomplete all as specified and directedbyEndineer -in -Charge. 110 M&L PCC 1:3:6 (40mm graded stone aggregate) type C2,for filling of post hole complete all as specified and directedbyEndineer -in -Charge. 111 S & F for steel work in tubular trusses ,channels ,purlines, crange gantries, rails including special shaped washer, platesnuts and bolts, gusset plates, cleats,including necessary drillingetc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 including dismantling of framed trusses complete all as specified and directedbyEngineer -in -Charge. 112 S &F pre- painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by Engineer - in -Charge. 113 S &F pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by Engineer - in -Charge. 114 S&F for hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and clountersunk for balusters running bars, for doors, balusters, nosing to steps including embneding in concrete and screwing etc wid ties for roof including securing bolts, posts and struts in fencing including cutting tops shape as directed, drilling holes, notching for wire etc flat iron fillets (for securing wire mesh etc) including all necessary drilling, bolting or reveting etc, and similar work conforming to Fe-290 or Fe-165. complete all as specified and directedbyEndineer -in -Charge. 115 Cutting holes in brick walls in cement mortar exc. Half Brick but n. exc one brick for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 complete all as specified and as directed by Engineer-in-Charge. 116 M&L 15mm thick rendering in CM 1:4 to brick / concretre wall surface finished even & smooth without using extra cement complete all as specified and directed by Engineer – in – Charge. 117 S&F sinks made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes, including bedding in cement mortar on to dwarf wall or including fixing cantilever brackes and connection union pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm including 40mm dia waster fittings, brass chromium plated for glazed ware sinks, basins etc with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other and fixed complete all as specified and directed by Engineer – in – Charge. 118 S&Fstainless steel wire cloth 0.36mm nominal dia of wire and average width of apertue 1.40mm and fixed with stainless stell wire, staples complete all as specified and directed by Engineer – in – Charge. 119 S&F50mm bore dia High density polyethylene (HDPE) pipes of pressure rating 6kgf/sq cm complete all as specified and directed by Engineer – in – Charge. 120 M&L for framed work such as grills, gratings, etc with ends of bras shouldered and / or riveted, or forged into spikes; framed guard bars ; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks, portions framed and hung as gates, including pintle hinges, stops hand-made slidign bolts, etc and similar work conforming to Fe 290 Ged-E-165 complete all as specified and directed by Engineer – in – Charge. 121 M & Lfor concealed conduit point wiring complete for light/ fan on independent /combine boardwith cable 1.5 sqmm (Nominal area) FRLSPVC insulated multistranded unsheathed copper conductor,drawn in and includingPVC Concealed conduitpipe medium grade 20 mm dia, pipe hooks , elbows, juction covers and junction boxes , aftercutting in wall chasing for conduits and sinkings for modular metal flush boxes suitable lengthandthickness for mounting, switches, sockets,fan regulatorwith modular cover plate with frame and making the gooddisturbed surfaces of wallin CM 1:3 with white wash or existing colour including provision ofcontinuousearth continuity conductoralong with point wiring of 1.5 sqmm copper PVC insulated cable for one light/ fan point controlled by one switchand connected to commonearth dolly, complete all as specified anddirecedby the Engineer in charge 122 S & F switch piano flush type 5/6 Amps single pole one way complete all as specified and directed by Engineer - in -Charge. 123 S & F ceiling rose surface bakelitethree terminals complete all as specified and directed by Engineer - in -Charge. 124 S & F light fitting with LED lights fitting 1x 20W, 220V,AC , 50 Hz , 6500K decorative box type aluminium housing with driver, holder includingLED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete, and all other accessories including connection with flexiblecable copper conductortwin coreof size 23/.2 mm upto ceiling rose/connector complete all as specified and directed by Engineer - in -Charge. 125 Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed by Engineer - in -Charge. 126 S & F angle holder insulated body with back plate for conduit fittings complete all as specified and directed by Engineer - in -Charge. 127 S&F LED lamp 9W for angle holder complete all as specified and directed by Engineer - in -Charge. 128 S & FWater tight bulk head fitting (New pattern),comprision of connector, weather proof enamelled gallery ,including 10 watt LED llight with separate driverall as specified and directed by Engineer - in -Charge. 129 Material and labour Sub main wiring alongwith earth wire of size 2 x 4.0 sqmm + 1 x 4.0 sqmm earth wire ISI marked FRLSH PVC insulated multi stranded copper conductor , single core cable drawn in and including PVC concealed conduit ISI marked medium grade of adequate size with all conduit accessories medium grade ISI marked as specified and directed by Engineer - in -Charge.Note: (i) Two run of PVC wire and one run of earth wire, 1 run of conduit will be measured as one length. 130 S&F security light fitting LED TYPE 25 watt with all necessary acessories, Clear transparent acrylic cover, prewire suitable to operated on 230 volt 50 HZ AC & Supply and fixing to wall / on pole including fixing arrangement with suitable galvanized iron pipe 35 mm bore “light grade” brackets 2 mtr length bent to shape to obtained required shape including clamps, nuts / bots / washers etc connecting with suitable flexible copper wire of size 23/0.0076 complete all as specified and directed by Engineer - in -Charge 131 S&Fsteelbody exhaust fan of 300mm sweep , 240 volt , 5 star rating complete with louvers and shutter and mounted in suitable opening arrangement in wall and connecting up including 3 core PVC insulated PVC sheathed copper conductor flexible cable 24/0.2mm from ceiling rose to fan complete including breaking of brick wall and making a hole for fixing of exhaust fan including grouting of bolts and making good to disturbed wall in CM (1:4) white washing matching with existing color etc complete all as specified and directed by Engineer - in -Charge 132 S&F Heavy duty metal body exahust fan of 250mmsweep ,240 volt,copper winding, complete with louvers and shutter and mounted in suitable opening arrangement in wall and connecting up including 3 core PVC insulated PVCsheathed copper conductorflexible cable 24/0.2mm from ceiling rose to fan complete including breaking of brick wall and making a hole for fixing of exhaust fan including grouting of bolts and making good to distubed wall in cement mortar (1 :4) white washing matching with existing colour etc complete all as specified and directed by Engineer - in -Charge. 133 S & F in repairs sheet metal enclosure for double door DBs made out of CRCA mild steel sheet surface with insulated material like polyester with epoxy powder coated surface mounted SPN 4 ways, 240 Volts, ISI marked 200 amps bus bar stove enameled dust and vermin proof suitable for incorporation MCBs and isolators etc complete all as specified and directed by Engineer - in -Charge. 134 S & FMCB ‘C’ series type suitable for 240 volts,10 KA,AC supply SPN 32 Amps , with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed by Engineer - in -Charge. 135 S & FMCB ‘B’ series type suitable for 240 volts,10 KA,AC supply6Amps , single pole (SP) with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed by Engineer - in -Charge. 136 M & L for Earthing complete with GI earth plate electrode 60 cm x 60 cm x 6 mmthick burried directly in ground (earth pit not less than 2.25 Mtr deep below ground level ) with top edge of plate not less than 1.5 Mtr below ground level , connecting to GI earth lead 4 mm dia GI earth wire ,by means of bolts,nuts and washers of GIand protection by provisionof GI medium grade pipe 15 mm bore including provision of concrete pit in PCC (1:2:4) type B1 using 20 mm grade stone aggregate with 40 mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4 gs /Sqmm ) and frame of angle iron 25mmX25mmX6mm with lugs 02 Nos and with 6 mm dia MS bar handle made to shape ,GI light grade 20mm bore pipe for watering perforated at the bottom 1.75 meter long placed ontop edge of earth plate common salt and charcoal filling test point made out of 40 mmX 8 mm FI with fixing arrangement ,funnel, wire mesh and earth work inhard dense soil ,returning filling in and removal of surplus soil to a distance not exceeding50 mtrs all as per electric plate no.3 of SSR part 1 and connecting to earth test point including taking out unserviceable earthing with all acessories all as specified or indicated including testing on completion all as specified and directed by Engr -In - Charge 137 Supply and lay jointing and testing and commissioning in replacement of 10 Sqmm x2 core XLPE insulated, screened , PVC bedded galvanised steel strip or wire armoured electric power cable heavy duty multi stranded aluminium conductor & PVC sheathed LT cable 1100 V grade conforming to IS-7098 laid in trenches/ducts/fixed on poles wall/laid under roads/paths/drain/culverts or passing through pipes complete all as specified and directed by engineer in charge. 138 Supply and lay GI pipe 40 mm bore light grade for cable protection in walls trenches or any situation including clamp nut bolt etc complete all as specified and directed by Engineer-in-Charge. 139 Supply and filling in Sand for Cable protection complete all as specified and directed by Engineer-in-Charge. 140 Supply and lay standard size bricks subclass B typecomplete all as specified and directed by Engineer-in-Charge. 141 Supply and laying GI pipe medium grade ISI marked 25mm dia including all fittings in old/new position complete all as specified and directed by Engineer-in-Charge. 142 Supply and Fixing GI pipe medium grade ISI marked 20mm bore including all fittings on wall or laid on floor in old/new position as directed by Engineer-in-Charge 143 Supply and Fixing GI pipe medium grade ISI marked 25mm bore including all fittings on wall or laid on floor in old/new position complete all as specified and directed by Engineer-in-Charge. 144 M & L cutting existing GI water turbing of size 25 mm bore for alternation or addition including screwing/threading and jointing with suitable size GI socket complete all as specified and as directed by Engineer-in-Charge. 145 Note :(i) Amount ofcredit for retrieved materials is mentionedin Sch A Section-II of tender documents in pdf form which will be deducted while acceptance of tender offline.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 21-09-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 28-09-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 64000.0 /-
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail