|
| 1 | Excavation in trenches in soft/loose soil not exceeding 1.50 mtr wide and not exceeding 1.50 mtr in depth for laying of cables and gettingout complete all as specifiedand as directed. by Engineer-in-Charge. |
| 2 | Returning, filling in, including spreading, leveling watering and well ramming in layers not exceeding 25 cms thick each layer compete all as specified and as directed. by Engineer-in-Charge |
| 3 | Removal of surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point completeall as specified and as directed. by Engr-in-charge. |
| 4 | Material and labour for sand cushioning with a layer of sand 8cm thick before laying of cable and 15 cm thick after laying of cable in trenches and punned down complete all as specified.Note : Punned down thickness of 18cm shall be measured for payment. |
| 5 | Supply & laying old size sub class \"B\" bricks laid flat in trenches over the cable with the length of brickperpendicular to the directionof cable length, adjacent/abutting each othercomplete all as specified and as directed. by Engineer-in-charge. |
| 6 | Material and labour for boring hole under the road / pavement / hard standing with the help of trenchless technology using ultra sound technique and necessary machine including DWC pipe of 150mm dia suitable for SN8working pressure as per IS - 16098, not less than one metre below ground level complete all as specified & directed by Engineer-in-charge |
| 7 | Material and labourfor PCC (1:4:8)type D-2 using 40 mm graded stone aggregatein foundation of electric pole, platforms etc. including necessary form work and fare finish to exposed surfaces without using extra cement etc. complete all as specified |
| 8 | Material and labour for PCC (1:3:6) type C-2 using 40 mm graded crushed stone aggregate as in foundation of stay / coping of poles including necessary form work and fare finish to exposed surfaces without using extra cement etc. complete all as specified |
| 9 | Supply, laying, jointing and testing 1100 volts grade LT underground XLPE insulated, PVC sheathed (heavy duty) electric strip/ wire armoured electric cable of size 6 Sqmm 2 core with stranded aluminium conductor, laid in trenches, in floor, in duct, through pipes or along the polecomplete all as specified and as directed.Make of cable:- Havells/ CCI/ Gloster/ Polycab. |
| 10 | All as per Srl Item No. 9.00 here-in-before but of size 10 sqmm 2 core.Make of cable:- Havells/ CCI/ Gloster/ Polycab. |
| 11 | All as per Srl Item No. 9.00 here-in-before but of size 16 sqmm 2 core.Make of cable:- Havells/ CCI/ Gloster/ Polycab. |
| 12 | All as per Srl Item No. 9.00 here-in-before but of size 16 sqmm 4 core.Make of cable:- Havells/ CCI/ Gloster/ Polycab. |
| 13 | All as per Srl Item No. 9.00 here-in-before but of size 25 sqmm 3.5 core.Make of cable:- Havells/ CCI/ Gloster/ Polycab. |
| 14 | All as per Srl Item No. 9.00 here-in-before but of size 35 sqmm 3.5 core.Make of cable:- Havells/ CCI/ Gloster/ Polycab. |
| 15 | All as per Srl Item No. 9.00 here-in-before but of size 50 sqmm 3.5 core.Make of cable:- Havells/ CCI/ Gloster/ Polycab. |
| 16 | All as per Srl Item No. 9.00 here-in-before but of size 70 sqmm 3.5 core.Make of cable:- Havells/ CCI/ Gloster/ Polycab. |
| 17 | All as per Srl Item No. 9.00 here-in-before but of size 120 sqmm 3.5 core.Make of cable:- Havells/ CCI/ Gloster/ Polycab. |
| 18 | All as per Srl Item No. 9.00 here-in-before but of size 185 sqmm 3.5 core.Make of cable:- Havells/ CCI/ Gloster/ Polycab. |
| 19 | Supply and fixing in replacement for pre-stressed concrete poles LT 9 Mtr long 102 mm x 172 mm at top and 102 mm x 279 mm at bottom class-10, complying with requirement of IS-1678-1998, fixed truly in vertical position, painting of pole with two coats of synthetic enamel paint with black and white strips of 30 cm each upto 1.5 mtr height from top of PCC coping and numbering of poles all as specified and as directed. by Engineer-in-Charge.Note : Cost for PCC in foundation & coping of poles and earth work to be measured & paid separately |
| 20 | Taking down existing light any type incl with pipe bracket and clamp from existing pole and refixing LED street light luminaire 45 watt or any other wattage at new PCC pole fixing on incl fixing of pipe bracket and clamps, nut bolts complete all as specified & directed by Engineer-in-Charge. |
| 21 | Supply and fixing LED street light luminarie 60 watt in epoxy / powder coated pressure die-cast aluminium housing with, heat resistant toughened clear glass/polycarbonate cover fixed with SS screws controlled with potted CVCC type, BIS marked electronic driver duly enclosed, of approved brand only in housing having protection against over voltage, short circuit and open circuit and surge protection against lightening of 4 KV minimum in circuit and 10 KV outside the fixture, can with stand 440 V AC Class-1 protection for LED and control gear compartments with high power LED chips of rating 2.5 to 3 watt (minimum) (make Osram/Nishia/ Cree/ Philips) with colour temperature 5700 K (Max) and with secondary optics lenses to minimize glare and for better distribution of light suitable for voltage 220 Volt, power factor 0.95 (minimum) having efficacy 100 lumens/ watt complete all as specified and as directed.Notes : (i) All LED fitting shall be made in India only. (ii)Contractor shall be provided 2 years written manufacturer’s warranty for the LED fixture complete including driver from the certified date of completion. (iii) Contractor shall be produce LM-79 & LM-80 report of NABL accredited laboratory from manufacturer\"s local office.(iv) Payment of lights shall be released only after contractor provides documents mentioned at SI No. (ii) &(iii).Make:- Philips/ Havells/ CG/ Bajaj. |
| 22 | Material and labour for cross arms, bracings, brazing stiffners, supports, clamps and back plated fabricated from structural steel section including nuts, bolts and washers, welding, bending, cold or hot drilling holes of any shape and size as directed incl two coat of aluminium paint (under and finishing coat) over a coat of red oxide or primer complete all as specified and as directed. |
| 23 | Supply and fixing bracket made out of 25mm dia GI light grade pipe (IS-1239), 1.2 metre long and bent to shape at 120 degree angle at the middle or as directed, fixed with clamps nuts and bolts, washer incl two coat of Aluminium paintcomplete all as specified.Note : Clamps, nut, bolts and washers will be measured and paid separately. |
| 24 | Supply and fixing factory made junction box of size 250 x 300 x 125mm approx or next higher size available suitable for street light fixed on pole, made out of thermoplastic having front hinged shutter with lockable arrangements, outdoor type, weather proof incl fixing clamp duly painted two coats over a coat of red oxide primer, having the provision to connect incoming and outgoing cable of size 25 sqmm 2 core and one number MCB SP, 10 KA, C -curve, 6 Amps, 240 volts and earthing plug complete all as specified and as directed. by Engineer-in-Charge.Note : MS Clamps, nuts, bolts required to fixing on pole shall be measured and paid separately. |
| 25 | Supply and fixing 1100 volt grade core PVC insulated PVC sheathed with stranded copper conductor 1.0 sqmm 3 core wire, ISI marked drawing through 20mm diaor next higher size steel conduit fixed with clamp for connection purpose complete all as specified and as directed. by Engineer-in-ChargeNote:- Clamp shall be measured and paid separately. |
| 26 | Earthing completewith galvanised steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground vertically at a depth not less than2.25 metres below normal ground level with top edge of the plate at a depth not less than 1.5 metres belownormalgroundlevel,connected with and including GI strip 32x6mmin andincluding GI pipe 40mm bore light grade (IS-1239) as protection pipe (from top of earth plate up to the test point) by means of GI bolts, nuts, check nuts and washers of GI and thimbles, earth plate surrounded by packed layers of charcoal dust and common salt 15cm thick, all around includingtop and bottom and watering pipe 20mm bore of GI pipe light grade with funnel and wire mesh, PCC chamber of size 300x300x300mm(top of chamber minimum 15 cm above the normal ground level (1:3:6) using 20mm graded stone aggregate and RCC cover (1:2:4) type B-I using 20mm graded crushed stone aggregate of 25mm thick with 2 nos MS handles of 12mm dia including necessary excavation/ earth work in any type of soil/rock and as shown in Electrical plate No. 3 of SSR Part-I (2009) testing on completion complete all as specified. |
| 27 | Earthing completewith galvanised steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground vertically at a depth not less than2.25 metres below normal ground level, from top of earth plate up to the test point with top edge of the plate at a depth not less than 1.5 metres belownormalgroundlevel,connected with and including GI wire 4mm in andincluding GI pipe 15 mm bore light grade as protection pipe by means of GI bolts, nuts, check nuts and washers of GI and thimbles, earth plate surrounded by packed layers of 15 cms thick charcoal dust and common salt 15cm thick, all around including top and bottom and watering pipe 20mm dia bore of GI pipe light grade with funnel and wire mesh, PCC (1:3:6) chamber of size 300x300x300mm (top of chamber minimum 15 cm above the normal ground level using 20mm graded stone aggregate and RCC cover (1:2:4) type B-I using 20mm graded crushed stone aggregate of 40 mm thick with 2 nos MS handles of 12mm dia of size 300mm x 300 mm in angle iron frame of size 40mm x 40mm x 6mm thick including necessary excavation/ earth work in any type of soilall as shown in Electrical plate No. 3 of SSR Part-I (2009) testing on completion complete all as specified. |
| 28 | Supply and fixing GI pipe 80 mm bore light grade (ISI marked) for protection of cable including bends or any other fitting complete for fixing alongGI pipe along wall/ pole/laid under the road/ floor complete all as specified and as directed. by Engineer-in-Charge. |
| 29 | Supply and fixing GI pipe 50 mm bore light grade (ISI marked) for protection of cable including bends or any other fitting complete for fixing alongGI pipe along wall/ pole/laid under the road/ floor complete all as specified and as directed. by Engineer-in-Charge. |
| 30 | Supply and fixing GI pipe 40 mm bore light grade (ISI marked) for protection of cable including bends or any other fitting complete for fixing alongGI pipe along wall/ pole/laid under the road/ floor complete all as specified and as directed. by Engineer-in-Charge. |
| 31 | Supply and fixing GI pipe 25 mm bore light grade (ISI marked) for protection of cable including bends or any other fittingcomplete for fixing alongGI pipe along wall/ pole/laid under the road/ floor complete all as specified and as directed. by Engineer-in-Charge. |
| 32 | Supply and fixing timer switches astro type (Having longitude and latitude of Indian cities in memory) 250 V single phase of 20 Amp rating with 3 pole contactor fitted inside steel enclosure inclMCB TPN 32Amp, one MCB SP 32 Amp to override timer complete with fixing clamp all as directed.Make:- Schneider/ ABB/ Legrand. |
| 33 | Taking down cross arms, channels, angle iron, clamps, nut, bolts, stay wire, stay assembly, GI wire,anti climbing devices, danger notice boards etc complete for re-use at siteall as specified and as directed. by Engineer-in-Charge |
| 34 | Taking down service wires of size 2.5/ 4sqmm 2 core or any size upto 16sqmm complete for taking credit of UNSV wire and re-using for fixing serviceable calbe all as specified and as directed.Note:- The decision of GE regarding serviceability condition of cable will be final. |
| 35 | Dismantling insulators any type, any size from existing LT poles street light feeders complete all as specified and as directed. |
| 36 | Dismantling old LT PCC/ steel tubular poles complete uprooting from foundation for taking credit complete all as specified and as directed. |
| 37 | Dismantling of old ACSR or AAC conductors for taking credit all as specified and as directed.. |
| 38 | Taking out old unserviceable/ serviceable cable of any sizes and type from trench & pole including disconnecting all electrical connections and removing unserviceable cable from site to take credit and re-using serviceable cable complete all as specified and as directed.. |
| 39 | Supply, install, testing and commissioning of LT Panel, outdoor cubicle type weather andvermin prooftotally enclosed made out of 3.15 mm thick CRCA sheet powder coated machine pressed of 1500mm x 1200mm x 600mm min size, suitable to operate on 3 phase 4 wire system , 415volts, 50 Hzdouble door with front and rear openablewith locking arrangement incl legs of panel with angle iron of size 50 x 50 x 6mm,1000mm long inner shutters for mounting switchgears etc, independent bottom gland plate for each incoming & outgoing cable of suitable size as per switchgear rating, having apron on 3 sides of panel from base to ground level of min. height 400mmprewired complete duly powder coated with 7 tank process comprising with following complete all as specified:-(i) Bus bar ,four pole of capacity 400 Amps copper stripbased on 1.5 Amps per sqmm, coloured with heat shrinkable / plastic coated insulatedsleeves in four colours (Red, Yellow , blue and black ) fixed on porcelaininsulators with necessary nuts and bolts and washers etc .Make of LT panel:- ABB/ L&T/ Siemens.(ii) INCOMING : -(a) MCCB 250 Amp, 415 V, 36 KA, 4 pole with adj thermal adj. magnetic release -01 Nos.(ICS=100% ICu)(b) Multi function meter to display Amp, Voltage, PF etc -1 No with set of CT\"s.(c)Energy meter with LCD display showing KWH, KVAh - 01 Nos(d)Indicator with neon lamps for RYB-01 set |
| 40 | (iii) OUTGOING:-(a) MCCB 160 Amp, 415 V, 25 KA, 4 pole with adj thermal magnetic release -01 Nos.(ICS=100% ICU)(b) MCCB 100 Amp, 415 V, 16 KA, 4 pole with adj thermal magnetic release -01 Nos.(ICS=100% ICU)(c) MCCB 40 Amp, 415 V, 16 KA, 4 pole with adj thermal magnetic release -01 Nos.(ICS=100% ICU)(d) MCB TPN 32 Amp, 415 V, 10 KA, C-Curve - 01 Nos.(e) MCB SPN 40 Amp, 230 V, 10 KA, C-Curve - 14 Nos. f) Spare space for MCCB 100 Amp |
| 41 | Supply, install, testing and commissioning of LT Panel, outdoor cubicle type weather andvermin prooftotally enclosed made out of 3.15 mm thick CRCA sheet powder coated machine pressed of 1600mm x 1200mm x 600mm min size, suitable to operate on 3 phase 4 wire system , 415volts, 50 Hzdouble door with front and rear openablewith locking arrangement incl legs of panel with angle iron of size 50 x 50 x 6mm,1000mm long inner shutters for mounting switchgears etc, independent bottom gland plate for each incoming & outgoing cable of suitable size as per switchgear rating, having apron on 3 sides of panel from base to ground level of min. height 400mmprewired complete duly powder coated with 7 tank process comprising with following complete all as specified:-(i) Bus bar ,four pole of capacity 300 Amps copper stripbased on 1.5 Amps per sqmm, coloured with heat shrinkableplastic coated insulated sleeves in four colours (Red, Yellow, blue and black ) fixed on porcelaininsulators with necessary nuts and bolts and washers etc .Make of LT panel:- ABB/ L&T/ Siemens.(ii) INCOMING : -(a) MCCB 160 Amp, 415 V, 25 KA, 4 pole with thermal adj. magnetic release -01 Nos.(ICS=100% ICU) |
| 42 | (b) Multi function meter to display Amp, Voltage, PF etc -1 No with set pf CT\"s of suitable rating(c)Energy meter with LCD display showing KWH, KVAh - 01 Nos(d)Indicator with neon lamps for RYB -01 set(iii) OUTGOING:-(a) MCCB 40 Amp, 415 V, 16 KA, 4 pole with thermal magnetic release -07 Nos.(ICS=100% ICU)(b) MCB SPN 40 Amp, 230 V, 10 KA, C-Curve - 13 Nos.(c) MCB TPN 32 Amp, 415 V, 10 KA, C-Curve - 01 Nos |
| 43 | Supply, install, testing and commissioning of LT Panel, outdoor cubicle type weather andvermin prooftotally enclosed made out of 3.15 mm thick CRCA sheet powder coated machine pressed of 1400mm x 1200mm x 600mm min size, suitable to operate on 3 phase 4 wire system, 415volts, 50 Hzdouble door with front and rear openablewith locking arrangement incl legs of panel with angle iron of size 50 x 50 x 6mm,1000mm long inner shutters for mounting switchgears etc, independent bottom gland plate for each incoming & outgoing cable of suitable size as per switchgear rating, having apron on 3 sides of panel from base to ground level of min. height 400mmprewired complete duly powder coated with 7 tank process comprising with following complete all as specified:-(i) Bus bar ,four pole of capacity 200 Amps copper stripbased on 1.5 Amps per sqmm, coloured with heat shrinkableplastic coated insulatedsleeves in four colours (Red, Yellow, blue and black ) fixed on porcelaininsulators with necessary nuts and bolts and washers etc.Make of LT panel:- ABB/ L&T/ Siemens. |
| 44 | (ii) INCOMING : -(a) MCCB 100 Amp, 415 V, 16 KA, 4 pole with thermal magnetic release -01 Nos.(ICS=100% ICU)(b) Multi function meter to display Amp, Voltage, PF etc -1 No with set of CT\"s of suitable rating.(c)Energy meter with LCD display showing KWH, KVAh - 01 Nos(d)Indicator with neon lamps for RYB -01 set(iii) OUTGOING:-(a) MCCB 40 Amp, 415 V, 16 KA, 4 pole with thermal magnetic release -03 Nos.(ICS=100% ICU)(b) MCB SPN 40 Amp, 230 V, 10 KA, C-Curve - 07 Nos.(c) Spare space for 100A, 415V, 4 Pole MCCB |
| 45 | Supply, install, testing and commissioning of LT Panel, outdoor cubicle type weather andvermin prooftotally enclosed made out of 3.15 mm thick CRCA sheet powder coated machine pressed of suitable size having depth 550 mm min, suitable to operate on 3 phase 4 wire system , 415volts, 50 Hzdouble door with front and rear openablewith locking arrangement incl legs of panel with angle iron of size 50 x 50 x 6mm,1000mm long inner shutters for mounting switchgears etc, independent bottom gland plate for each incoming & outgoing cable of suitable size as per switchgear rating, having apron on 3 sides of panel from base to ground level of min. height 400mmprewired complete duly powder coated with 7 tank process comprising with following complete all as specified:-(i) Bus bar ,four pole of capacity 200 Amps copper stripbased on 1.5 Amps per sqmm, coloured with heat shrinkableplastic coated insulatedsleeves in four colours (Red, Yellow, blue and black ) fixed on porcelaininsulators with necessary nuts and bolts and washers etc .Make of LT panel:- ABB/ L&T/ Siemens. |
| 46 | (ii) INCOMING : -(a) MCCB 100 Amp, 415 V, 16 KA, 4 pole with adj thermal magnetic release -01 Nos.(ICS=100% ICU)(b) Multi function meter to display Amp, Voltage, PF etc -1 No with set of CT\"s of suitable rating.(c)Energy meter with LCD display showing KWH, KVAh - 01 Nos(d)Indicator with neon lamps for RYB , -01 set(iii) OUTGOING:-(a) MCCB 63 Amp, 415 V, 16 KA, 4 pole with fixed thermal magnetic release -01 Nos.(ICS=100% ICU)(b) MCCB 40 Amp, 415 V, 16 KA, 4 pole with fixed thermal magnetic release -01 Nos.(ICS=100% ICU)(c) MCB TPN 40 Amp, 415 V, 10 KA, C-Curve - 01 Nos.(d) MCB SPN 40 Amp, 230 V, 10 KA, C-Curve - 06 Nos |
| 47 | Supply, install, testing and commissioning of LT Panel, outdoor cubicle type weather andvermin prooftotally enclosed made out of 3.15 mm thick CRCA sheet powder coated machine pressed of suitable size having depth 550mm min, suitable to operate on 3 phase 4 wire system, 415volts, 50 Hzdouble door with front and rear openablewith locking arrangement incl legs of panel with angle iron of size 50 x 50 x 6mm,1000mm long inner shutters for mounting switchgears etc, independent bottom gland plate for each incoming & outgoing cable of suitable size as per switchgear rating, having apron on 3 sides of panel from base to ground level of min. height 400mmprewired complete duly powder coated with 7 tank process comprising with following complete all as specified:-(i) Bus bar ,four pole of capacity 200 Amps copper stripbased on 1.5 Amps per sqmm, coloured with heat shrinkableplastic coated insulated and sleeves in four colours (Red, Yellow, blue and black ) fixed on porcelaininsulators with necessary nuts and bolts and washers etc .Make of LT panel:- ABB/ L&T/ Siemens. |
| 48 | (ii) INCOMING : -(a) MCCB 100 Amp, 415 V, 16 KA, 4 pole with fixed thermal magnetic release -01 Nos.(ICS=100% ICU)(b) Multi function meter to display Amp, Voltage, PF etc -1 No with set of CT\"s of suitable rating.(c)Indicator with neon lamps for RYB -01 set(iii) OUTGOING:-(a) MCCB 40 Amp, 415 V, 16 KA, 4 pole with fixed thermal magnetic release -01 Nos.(b) MCB TPN 40 Amp, 415 V, 10 KA, C-Curve - 01 Nos.(c) MCB SPN 40 Amp, 230 V, 10 KA, C-Curve - 05 Nos.(d) Spare space for 63A, 415V , 4 Pole MCCB |
| 49 | Supply, install, testing of Feeder pillar, outdoor cubicle type weather andvermin prooftotally enclosed of min. size 450mm x 450mm x 300mm made out of 3.15 mm thick CRCA sheet machine pressed of suitable size, suitable to fix on wall and suitable to operate on 3 phase 4 wire system , 415volts, 50 Hzsingle door with frontopenablewith locking arrangement, incl legs of panel made up of angle iron of size 50 x 50 x 6 mm, 1000mm long inner shutters for mounting switchgears etc, independent bottom gland plate for each incoming & outgoing cable of suitable size as per switchgear rating, prewired complete duly powder coated with 7 tank process comprising with following complete all as specified:-(i) Bus bar four pole of size 25 x 6mm , coloured with plastic coated insulated and sleaves in four colours (Red, Yellow, blue and black) fixed on porcelaininsulators with necessary nuts and bolts and washers etc (ii) Multifunction meter to display voltage, current, PF-01 No with CT\"s set of suitable rating. |
| 50 | (iii) INCOMING : -(a) MCCB 40 Amp, 415 V, 16 KA, 4 pole with fixed thermal magnetic release -01 No.(b)Indicator with neon lamps for RYB-01 set(iv) OUTGOING:-(a) MCB DP 40 Amp, 230 V, 10 KA, C-Curve - 8 Nos.Notes for Srl item No. 39.00 to 44.00.(i) All LT panels/feeder pillars shall have sliding bolt on rear and front door of panel.(ii) All door of panel should have minimum three nos. of hinges on leaf of door.(iii) All MCCBs should provided with phase extendes/ spreader links / spacer on both ends.(iv) Make of MCCBs : Havells/ Legrand/ Siemens/ ABB/ Schneider.(v) All MCCB shall have Ics=100% Icu.(v) The size mentioned of LT panel are minimum. However, no cost effect will be paid if higher size of panel is reqd to accommodate all accessories/ switcher. |
| 51 | Supply and fixing Heat shrinkable end joint kit suitable for 1100V XLPE/ PVC cable of size150-185 sqmm 3.5 core complete all as specified and as directed..Make : Denson / 3M/Raychem |
| 52 | Supply and fixing Heat shrinkable end joint kit suitable for 1100VXLPE/ PVC cable of size95-120 sqmm 3.5 core complete all as specified and as directed..Make : Denson/ 3M/ Raychem |
| 53 | Material and labour for fixing a PVC sleeve on 4 core of cable and connected the same to electrical system with new aluminium lugs of proper size complete all as specified and as directed..Note : Each sleeve length should not be less than 0.5mtr and rate quoted inclusive of new lugs and heating arrangement |
| 54 | Material and labour for fixing a PVC sleeve on 2 core of cable and connected the same to electrical system with new aluminium lugs of proper size complete all as specified and as directed..Note : Each sleeve length should not be less than 0.5mtr and rate quoted inclusive of new lugs and heating arrangement |