tender for Pump Motor Repair And Services To Hennagara Grama Panchayath Anekal Taluk - Cable 6 Sq Mm,Studs And Nuts (Bwssb Sr 2014-15), P 84 I.C-8,Bearing (Gun Metal Centrifugally Cast Aluminium, Bronze, Bearing Bush (Bwssb Sr 2014-15), P-84, I.C9,Circlips,Motor Base With Pin (Bwssb Sr 2014-15), P-84, I.C11,Transportation Of Pumping Machineries,Supplying And Drawing 3 Core Flat Pvc Shelted Submersible Pump Cable Manufactured With Electrolytic Grade Copper With Flexible Copper Conductor Confirming To Table 3 Class 5 Of Is 8130- 1984 And Virgin Pvc Insulation And Sheeated Suitable For Working Voltage Upto 1100 Volts As Per Page No. 408 Item No.30/C(A) Bwssb Sr 2014-15,Supplying And Fixing 50Mm Gi Pipe C Class Heavy Duty For Erection Of Submersible Pumpset (As Per Bwssb Store Issued Rate),Motor 50 Stage Pump 5 Hp,Digging Of Trench Of 1.00Mm Deep X 0.60 Mtr Wide Refilling The Trench To The Required Ground Level And Consolidating Etc Complete (As Per Pre Sr-2011-12 Page No.1, Item 1.2.1, In Ordinary Soil,Ug Cable Labour Charges D) 4 Core 16 Sqmm As Per Electrical Sr Pwd 2010-11 (P.68-69, I No. I Class A Pvc Cable),Refilling Available Earth Around Pipe Lines, Cable In Layers Not Exceeding 20Cms In Depth, Compacting Each Deposited Layer By Ramming After Watering With Lead Upto 50M And Lift Upto 1.5M Including Cost Of All Labour Complete As Per Specification Presr-2011-12 Page No.3, Item No.1-6.,Fabricating Supplying And Mounting Ms Box Made Out Of 16 Swg Suitable For Floor/Wall Mounting Fully Weather Proof With Provision For Better Heat Dissipation, Provided With Hinged F Ront Cover, Equipped With Tamper Proof Locking Arrangements, With Suitable Size Clamps With Necessary Cable Entry Pipe With Gland And Box Should Be Finished With 2 Coats Of Red Oxide Primer Paint And Finally Finished With Approved Colour Enamelled Metal Paint Etc Complete (Bwssb Sr 2014-15 P-524, I-39(B)),Supply And Fixing Angle Iron Frame Work Fabricated Out Of Ms Angle Iron And Ms Flat With Bolts, Washers Etc And Painted With 2 Coats Of Red Oxide And Then Two Coats Of Approved Paint 40 X 40 X 6Mm (Bwssb Sr 2014-15 P-524, I-38(A)),Supply And Fixing Miniature Circuit Breakers On Existing Mcb Distribution Board Using Necessary Fixing Materials & Wiring Complete As Per Required (Bwssb Sr 2014-15 P-519-520, I-13(D)) 40 To 63 Amps,Supply And Fixing One Of The Fuse Cut Outs Having Porcelain Base Approved Quality On The Existing Wooden Block And Wiring Complete (Bwssb Sr 2014-15 P-515, I-3(A)) 63Ams,Supplying And Fixing 50Mm Gl Union, Pwd Sr 2013-14 Page No. Xxxviii, Gi Fittings,Cable 2.5 Sq Mm,Supplying And Fixing 50Mm Gi Elbow Pwd Sr 2013-14 Page No. Xxxviii, Gi Fittings,Supplying And Fixing 50Mm Gi Nipple Pwd Sr 2013-14 Page No. Xxxviii, Gi Fittings,Supplying And Fixing 50Mm Gi Collars Ce(M)Bwssb, Letter No. Bwssb/Ce(M)Ace(M)-Iita-08-9194/2008-09,Supply And Fixing Gun Metal Gate Valve 50Mm Nominal Bore (Pre Sr 2010-11 P Iv Sl No. 134),Struck Of Motor,Threading,Cable 4 Sq Mm,Ss Adopter,Mcb 32 Ams,Mcb 63 Ams,Pump Bowls (Bwssb Sr 2014-15), P 83 I.B.1,Oil Seal (Bwssb Sr 2014-15, P 83 I.B3,Oil Seal Bush (Bwssb Sr 2014-15), P 83 I.B4,Guide Vane (Bwssb Sr 2015-15), P 83 I.B5,Impeller (Shell Mounded With Aluminium And Bronze) (Bwssb Sr 2014-15), P 83 I.B6,Discharge Outlet (D.O) D.O Steel Bush D.O Bearing (Bwssb Sr 2014-15), P 83 I.B7,D.O Bearing,Steel Bearing Bush (D.O. Steel Bush) (Bwssb Sr 2013-14), P 83 I.B8,Allen Screw,Pump Shaft Made Out Of Stainless Steel Center Less Ground With Key Way,Pump Key (Stainless Steel),Pump Coupling (Stainless Steel) (Bwssb Sr 2014-15), P 83 I.B12,Non-Return Valve (Nrv) Assembly Complete With Rubber O Ring,Cable Guad,Strainer,Upper Flange (Bwssb Sr 2014-15), P-84, I.C-3,Lower Housing (Bwssb Sr 2014-15), P-84, I.C-4,Lower Flange,Lock Ring (Bwssb Sr 2014-15), P-84, S1 C6,Carbon Housing (Bwssb Sr 2014-15), P-59, Ic-7,Thrust Bearing Block Assembly Complete With Segment Bearing Paid (Bwssb Sr 2014-15), P-59, Ic-7,Tip Carbon / Ferrodod Padding (Bwssb Sr 2014-15), P-59, Ic-7,Motor 30 Stage Pump 15 Hp,Gi Pipes 2 Inches,Gi Collar 2 Inches,Clamp Set Cup,Bends With Mrv 2 Inches,Motor 36 Stage Pump 17.5 Hp,Motor 40 Stage Pump 20 Hp,Motor 75 Stage Pump 10 Hp,Motor 50 Stage Pump 20 Hp,Motor 67 Stage Pump 10 Hp,Panel Bord 15 Hp Motor,Panel Bord 17.5 Hp Motor,Panel Bord 20 Hp Motor,Hdpe Pipe 1 1/2,Collom Pipes Pvc 1 1/4,Hdpe Pipe 1 1/4,Cpvc Pipe 1 1/5,Cpvc Pipe 2Inch,Cpvc Collar 2Inch,Copper Wire 10 Squ Mm,Aluminium Wire 16 Sqm Mm,Stage Pump 5 Hp Motor 10,Stage Pump 7.5 Hp Motor 15,Motor10 Hp 20 Stage Pump,Motor 12.5Hp 25 Stage Pump,Motor 15 Hp 30 Stage Pump,Motor 17.5 Hp( 36 Stage Pump,Motor 20 Hp ( 40 Stage Pump,Motor 20 Hp (50 Stage Pump,Intermediate Piece (I.P) With I.P. Leaded Bronze Bush (Bwssb Sr 2014.15), P 58, I . B2,Labour Charges For Erection Repaired Submersible Pumpset Along With Cable And Gi Pipes (Each Length 6M) Bswwb Sr 2014.15, P. 564, S.I. 3) (Average 40 Length 1 Point 49 X 40. 1960),Labour Charges For Lifting Of Non Functioning Submersible Pump Set Along With Cable And Gi Pipe As Per Date Rate. Bwssb Sr 2014.15, Page No. 564, Item No. 1(A) (Average 40 Length 1 Point 49 X 40 . 1960),Ug Cable D) 4 Core 16 Sqmm . As Per Electrical Sr Pwd .2010.11 (P. 68.69 I. No. Iclass A Pvc Cable),Supplying Fully Automatic Star . Delta Starter Unit Push Button Type With Suitable Wires 3 Contractors, One Adjustable Thermal Timer Mounted On A Common Base Plate Held In Steel Enclosure For Use On 400/440 Volts 3 Phase And Wired After Fixing To The Existing Wooden Board For Motor.,Supply And Fixing Hylum Brand Hand Plastic Sheet 3Mm Thick With Necessary Nitches For Fixing Switches Regulators Etc And Fixing Of Exciting Wood Or Metal Box Using Nf Screw (Bwssb Sr 2014.15 P.509, I.23) 41 X 47 . 1947 X 15