}

Tender For Provision Of Certain E/M Works At Afs Bidar, bidar-Karnataka

Statutory Bodies & Commissions/Committees has published Tender For Provision Of Certain E/M Works At Afs Bidar. Submission Date for this Tender is 26-09-2024. Cleaning Consumables Tenders in bidar Karnataka. Bidders can get complete Tender details and download the document.




Tender Notice

45089672
Tender For Provision Of Certain E/M Works At Afs Bidar
Open Tender
Indian
Karnataka
Bidar
26-09-2024

Tender Documents

Tender Details

Tender For Provision Of Certain E/M Works At Afs Bidar; 1 S&F Mild steel perforated cable tray of size 300mm x 100mm (WxH) of suitable length industrial type open slot wiring raceway duct including specials, cable management channel cord track to hide cable wires for run electric cable to further distribute with deskes, shelves and DBs, panels for necessary cable protection ,cable tray should be made out of min 2mm thick Rolled sheet steel,the tray should be fabricated and fabrication process shall include pressing,punching, slotting,drilling,welding etc and shall be free from burr & sharp edges.After fabrication,the trays shall be Hot Dip Galvanized as per IS 2629-1989 and coverage as per IS 4759-1984.Min 610 gms/Sqm for trays minimum thickness of zinc deposits on all points shall be 75 microns including taking down old cable tray complete all as specified and as directed . 2 S&F PVC FRLS type heavy duty to sustain cable load of standard slot perforated cable tray industrial type size not less than 10 x 30cm ( H x W) of suitable length including with specials for cable ducts/wiringchannels/ cablesopen slot wiring raceway duct, cable management channel cord track to hide cable wires for run electric cable to further distribute with deskes, shelves and DBs, panels including taking down old cable tray complete all as specified and as directed . 3 All as per Item No.2 above above here in before but size not less than 10 x 20cm ( H x W) cable ducts/wiring channels/cables open slot wiring raceway duct, cable management channel cord track to hide cable wires for run electric cable to further distribute with deskes, shelves and DBs, panels complete all as specified and as directed . 4 All as per item No.02 above here in beore but size not less than 10 x 10cm ( H x W) cable ducts/wiring channels/cablesopen slot wiring raceway duct, cable management channel cord track to hide cable wires for run electric cable to further distribute with deskes, shelves and DBs, panels complete all as specified and as directed . 5 All as per item No. 02 above here in before but size not less than 5 x 10cm ( H x W) cable ducts/wiring channels/cablesopen slot wiring raceway duct, cable management channel cord track to hide cable wires for run electric cable to further distribute with deskes, shelves and DBs, panels complete all as specified and as directed . 6 All as per item No.02 above here in before but size not less than 2.5 x 5cm ( H x W) cable ducts/wiring channels/cablesopen slot wiring raceway duct, cable management channel cord track to hide cable wires for run electric cable to further distribute with deskes, shelves and DBs, panels complete all as specified and as directed . 7 Concealed Point wiring for one light point/fan point /bell point controlled by one switch (using red, black and green colour wires as colour coding) complete with 1.5 Sqmm (nominal cross section area)single core FRLSH PVC insulatedunsheathed and multi strand copper conductor cable 1100 volt (ISI marked)through and including concealed PVC 20mm dia (light duty) conduit and conduit accessories including 2mm thick galvanised steel pressed sunken box suitable modular switch socket (Min 60mm deep, suitable length) concealed in wall, including inner and outer plates (cover plate) suitable for fixing the modular switches / socket / regulator etc, including provn of 1.5 Sqmm single core FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. and incl taking down oldpoint wiring complete all as specified and as directed. 8 All as per Item No.07 above here in before but for One three pins 5 Amps switch socket outlet point on independent board 9 All as per Item No.07 above here in before but for One three pins 5 Amps switch socket outlet point on same board with other switches 10 All as per item No.07 above here in before but in existing conceales for 15 amps socket outlet with 2.5 Sqmm Copper incl 2.5 Sqmm PVC insulated copper conductor cable as earth continuity conductor and connecting to common earth dolly complete all as specified and directed. 11 All as per item No.07 above here in before but for 15 amps socket outlet with 4 Sqmm Copper incl 4.0 Sqmm PVC insulated copper conductor cable as earth continuity conductor and connecting to common earth dolly using color code as per IS and all as specified complete all as specified and directed. 12 Modular switch 5/6Amps, single pole, two way (1 module) complete all as specified and as directed. 13 Modular Socket outlet multipurpose type 6 Amp, flush type (2 module) complete all as specified and as directed . 14 Modular Socket outlet multipurpose type 6/16 Amp, flush type (2 module) complete all as specified and as directed . 15 Modular switch 6/16Amps, single pole, one way (1 module) complete all as specified and as directed . 16 Ceiling rose 3 terminals/phase type, fabricated of PVC/Polycarbonate, isolated bodycomplete all as specified and as directed . 17 Submain wiring comprisingsingle core 2 Runs of 10 sqmm nominal cross sectional areamultistranded copper conductor cable, PVC insulated unsheathed 1100 Volts gradedrawing in and including suitable dia of PVC conduits and conduit fittings/concealed conduit complete,including provision of 1 x 10 sqmm nominal cross sectional areamultistranded copper conductor cable PVC insulated unsheathed 1100 volts grade as earthwirecomplete including taking down old sub main wiring complete all as specified and as directed.Note :- Extra length of cables/ wire required for connection to MCBs shall not be measured and the rate quoted by contractor for per unit shall be deemed accordingly 18 All as per item No.17 above here in before but 2 Runs of 6 sqmm and one run of 6 sqmm as earth wire complete all as specified and as directed. 19 All as per item No.17 above here in before but 2 Runs of 4 sqmm and one run of 4 sqmm as earth wire complete all as specified and as directed. 20 All as per item No.17 above here in before but 4 Runs of 6 sqmm and two runs of 6 sqmm as earth wire complete all as specified and as directed. 21 All as per item No.17 above here in before but 4 Runs of 10 sqmm and two runs of 10 sqmm as earth wire complete all as specified and as directed. 22 Cutting chases, pinning in, making god to facings where reuired and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc ; and cutting chases for concealed water tubing or concealed wiring etc, and making good, cutting not exc 10 cm girth in brick walls complete all as specified and as directed. 23 Supply and laying or fixing or passing through pipe, 1100voltsgrade heavy dutycableof size 2 core 10 sqmm nominal cross section in service connections of PVC insulated aluminium multi standard conductor served with an inner sheathing of PVC tape andoverall PVC sheathed including taking down old service connection complete all as specified and as directed . 24 All as per Item No.23 above here-in-before but 2 core 6 sqmmcomplete all as specified and directed. 25 MCCB TPN4 pole 63 Amps 415 Volts of braking capacity 16 KAcomplete taking down old unserviceable one and making necessary connections as existing ls with CTC solutions complete all as specified and directed. 26 MCCB TPN 4 pole 100 Amps 415 Volts of braking capacity 16 KAcomplete taking down old unserviceable one and making necessary connections as existing ls with CTC solutions complete all as specified and directed. 27 MCCB TPN 4 pole 125 Amps 415 Volts of braking capacity 16 KAcomplete taking down old unserviceable one and making necessary connections as existing ls with CTC solutions complete all as specified and directed. 28 MCCB 125 Amp 4 pole 25 KAin existing panel board connecting with proper sizelink set, incoming, out going cable electrically connected and making necessary modification in existing panel as required at sitecomplete all as specified and as directed. 29 Refixing by re use serviceable light fitting and fixtures along with fixing accessories with exisitng surface complete all as specified and directed. 30 Refixing by re use serviceable MCCBs / AC Box / nato switch / DOL starter / DBs along with lugs / thimbles along with connecting accessories like neautral link, bus bar,glands complete all as specified and directed 31 Refixing/relaying of cable in cable duct/tray/on channel/on wall by using fixing arrangement to fix properly with existing surface complete all as specified and directed. 32 Taking down the wall/hanger fan 3 Phase 415 volt unscrewing and servicing/overhauling the same duly oiling and varnishing the winding and fixing its original position by replacing nut,bolt and washers and suitable electric cord wiring upto DOL starter and painting with one coat of synthetic enamel paint with existing colour complete all as specified and directed. 33 Taking down the wall/hanger fan 3 Phase 415 volt unscrewing and servicing/overhauling the same duly oiling and re- winding the same and fixing its original position by replacing nut,bolt and washers and suitable electric cord wiring upto DOL starter and painting with one coat of synthetic enamel paint with existing colour complete all as specified and directed. 34 Taking out the AC of any capacity by disconnecting chiller/condensor pipe, electric connection and servicing the AC duly cleaning,overhuling of indoor/out door units by using brush,AC cleaning material, brazing the units if any leakages and refixing the same its original posision complete all as specified and directed. 35 M&L for filling refregent gas into the serviceable AC of any capacity and type duly carried out leak testingto its serviceability after fixing all serviceable accessories with the existing unit complete all as specified and directed. 36 M&L for replacing copper pipe such as chiller/condensor line with new copper pipe by wrapping with heavy duty insulation and making connections with AC indoor and out door units in all respects its serviceability complete all as specified and directed. 37 M&L for PVC pipe of size 50 mm dia including with all fitting and provn of tee/bends to each AC drain pipe for AC drain water to flow and channeling the pipe to out side of the Hanger area drain duly fixing with saddles/clamps and fixing accessories complete all as specified and directed. 38 M&L for PVC pipe of size 15 mm dia including with all fitting and provn of tee/bends to each AC drain pipe for AC drain water to flow and channeling the pipe to out side of the Hanger area drain duly fixing with saddles/clamps and fixing accessories complete all as specified and directed. 39 M&L for replacing insulators with new for existing earth strip of any size by fixing interval of 1 mtr with nut,bolt and washers complete all as specified and directed. 40 M&L for copper earth strip of size 32x6 mm thick including provn of insulators,nut,bolt and washers of intervals of 1 mtr length includinh taking down old earth strip complete all as specified and directed. 41 S&F sheet metal enclouser VTPN/HTPN DB having facility to fix MCCBincomer upto 125 Amps and MCBs in outgoing, TPN 4 ways, Double door type complete fitted with bus bars, neutral links, IP-43 protection Isolated Neutral bar,door earthing,cement spill protector,insulated bus bar assembly and blanking plates including making good disturbed surfaces after taking out old unserviceable DB complete all as specified and directed. 42 S&F sheet metal enclouser TPN DB having facility to fix MCCBincomer upto 125 Amps and MCBs in outgoing, TPN 8 ways, Double door type complete fitted with bus bars, neutral links, IP-43 protection Isolated Neutral bar,door earthing,cement spill protector,insulated bus bar assembly and blanking plates including making good disturbed surfaces after taking out old unserviceable DB complete all as specified and directed. 43 S&F sheet metal enclouser TPN DB having facility to fix MCCBincomer upto 125 Amps and MCBs in outgoing, TPN 4 ways, Double door type complete fitted with bus bars, neutral links, IP-43 protection Isolated Neutral bar,door earthing,cement spill protector,insulated bus bar assembly and blanking platescomplete all as specified and directed. 44 S&F sheet metal enclouser SPN DB having facility to fix MCB in incomer and MCBs in outgoing, SPN 8 ways, Double door type complete fitted with bus bars, neutral links, blanking plates including making good disturbed surfaces after taking out old unserviceable DB complete all as specified and directed. 45 S&F sheet metal enclouser SPN DB having facility to fix MCB in incomer and MCBs in outgoing, SPN 8 ways, Double door type complete fitted with bus bars, neutral links, blanking platescomplete all as specified and directed. 46 S&F sheet metal enclouser SPN DB having facility to fix MCB in incomer and MCBs in outgoing, SPN 4 ways, Double door type complete fitted with bus bars, neutral links, blanking plates including making good disturbed surfaces after taking out old unserviceable DB complete all as specified and directed. 47 S&F PVC enclouser SPN DB 2 way having facility to fix MCB DP/SPN 2 ways complete fitted with bus bars, neutral links including provision of MCB DP 6-16A including making good disturbed surfaces after taking out old unserviceable DB complete all as specified and directed. 48 S& F in replacement ofMCBSP 240 Volts, of 6-32 amps current rating and 10 KA breaking capacity, B series type complete all as specified and directed. 49 S& F in replacement ofMCB, DP, 240 Volts, of 32-63 amps current rating of 10 KA complete all as specified and directed. 50 LED tube light fixture environmental friendly energy efficient of 18/20W LED 6500K and above (4) including electric connection with PVC copper flexible twin core cable, 1.0 sqmm from ceiling rose to light fitting includinh taking down old light fitting completeall as specified and as directed . 51 LED street light luminarie 35 watts with IP66 complete with pressure dia cast aluminium housing with GI pipe bracket made out of 25 mm dia medium grade pipe (60 cm long) bend to shape including fixing arrangement to wall with MS flat 25x3mm-2 Nos by nut, bolts and washers including electric connection with PVC copper flexible twin core cable 1.0 sqmm from ceiling rose to light fitting completeall as specified and as directed . 52 S & FLED high bay light fitting 120 watt with housing IP-65 and IK 07, circular high pressure die cast aluminium housing and manufacture logo embossed on the housing amd high transmittance tempered glass cover, optic lens plate having NB and WB optics, system efficacy >120 lumens / watt, xitanium driver - IP66 complying to IEC 61347-2-13 certification like CE ENEC, ROHS, with rated life of 50000 hrs for drover at TC- 800 C along with all safety features, thermal protection, protection against input over voltage < 320 volt AC for 48 hrs, driver failure rate 0.2% per 1 Khr @ TC 70-800 C , wattage 120 watt, internal wiring - teflon SDCM < 5, CCT-5700,CRI > 80, THD < 20 at max load, third harmonics < 20%, PF > .95 colour temperature 6500Kincluding taking down existing oldlight fittingscomplete all as specified and as directed. 53 M&L Tripod Earthing Completewith 3 numbers of Chemical earthing (maintenance free) using corrosion resistant earth electrode copper cladded, copper coating thickness of 250 microns, 17.20 mm dia, high tensile low carbon COPPER BONDED RODS WITH 99.9% with 25KA current discharge testfrom CPRI of length 3.0m as per UL 467, with suitable compressive coupler planted at depth not less than 3.0m of bore 100mm below gorund level and duly covered with low resistant superior conductive powdered non corrosive, highly hydrous earth enhancing material all as directed including connecting upto common bus bar grid of size 25 x 3 mm to achieve optimum low earth resistance on inspection/ testing including dismantling old earthing complete all as specified and as directed. 54 Supply and laying XLPE insulated, armouredheavy duty electric cable with aluminium conductor, 1100 volts grade cable cross-sectional area 6 sq. mm 4 core and including provision aluminium lugs to bothe ends for cable connections and taking down old cable, complete all as specified and as directed. 55 All as per item No.54 herein before but the size cross-sectional area 10 sq. mm 4 core 56 All as per item No.54 herein before but the size cross-sectional area 16 sq. mm 4 core 57 All as per item No.54 herein before but the size cross-sectional area 25 sq. mm 4 core 58 All as per item No.54 herein before but the size cross-sectional area 35 sq. mm 3.5 core 59 All as per item No.54 herein before but the size cross-sectional area 50 sq. mm 3.5 core 60 All as per item No.54 herein before but the size cross-sectional area 95 sq. mm 3.5 core 61 Supply and laying XLPE insulated, armouredheavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 sq. mm 2 core including provision of gland plates, gland and aluminium lugs to both ends of cable connections complete all as specified and as directed. 62 S&F in replacement ofof coupler plates for cable trays made out of 3mm thick steel sheet andplates shall have 8 holes(4holes & 4slots)suitable with tray dimensions complete all as specified and as directed. 63 S&F in replacement ofDOL starter MK-1 upto 5 HP 3 Phase 415 volt with necessary fixing arrangement including taking down the old one complete all as specified and directed. 64 Excavation in trenches not exceeding 1.5m wideand not exceeding 1.5m in depth for taking out / for layingunder ground cables / pipes etc and getting out in soft/loose soil complete all as specified and as directed. 65 Returning, filling in soil, including spreading, levelling, watering and well ramming in layers not exc 25 cm thick complete all as specified and as directed . 66 Removal of surplus excavated material ( soils) to a distance not exc., 50mand depositing where directed at a level not exc 1.5m above the starting point complete all as specified and as directed. 67 Supply and spreading natural river sand in trenches for cushioning of under ground cable complete all as specified and as directed.Note: Punned thickness will be measured and paid for purpose of the payment. 68 Supply and laying unreinforced pre cast concrete cable cover class LV, Type I, flat, size 250mm x 150mm x 40mm for cable protection complete all as specified and as directed. 69 S&F GI Steel tubing light grade of 100mm dia with fittings in trenches/wall/poles for cable protection complete all as specified and directed. 70 S&F GI Steel tubing light grade of 50mm dia with fittings in trenches/wall/poles for cable protection complete all as specified and directed. 71 Supply, fixing, testing and commissioning ofLT feederpillar box cubicle, outdoor type floor mounted , made out of CRCA sheet 3 mm thick and angle iron of suitable size weather proof/vermin proof shuuter type with locking arrangement pre wired with aluminium bus bar 500 Amps for phases and aluminium bus bar 300 Amps for neutralincluding suitable CTs etc., and powder coated painting suitable for accommodate with and including the following :-(a) MCCB, 4 Pole, 415 Volts, 250 Amp, 35 KA breaking capacity -01 No (b)MCCB, 4 Pole, 415 Volts, 63 Amp, 25 KA breaking capacity -07 No(c) Astronomical time switch complete withh all accessories in built panel- 01 No(d) Digital Voltmeter 0-500 volts with selector switch - 01 No (e) Digital Ammeter 0-60 Amp with selector switch - 01 No(f) Indicator lamp LBD type (R,Y,B) complete - 01 Set (g) MCB DP 6-40A , 415V, 50 Hz, 16 KA -24 Nos 72 S&F AC control timer for 02 Nos ACs with tempaerature LCD digital display heavy duty 30-30 Amps relay output time can be set 1 Hr to 12 Hrs temp can be set 0 degree to 80 degree Celcius high temp and low temp alarm facility fully messaging display and wall mounted metallic body with powder coated with isolated rugged power supply ISO9001, CE certified and MSME regt co complete all as specified and as directed.Make: Dynamaic Model CAPSOLE or equivalent as approved by GE. 73 S&F voltage stabilizer for window/Split AC capacity upto 1.5 Ton (working voltage range 170-270 volt) having LED indicator built in thermal overload protection low and high voltage cut off ntial time delay system complet all as specified and directed. 74 M&L for fabrication of MS structure with using heavy duty MS pipe of size 100 mm dia for communication tower, fabrication of MS channel of angle size not less than 75mmx75mmx6 mm thick of adequate length to hold the communication antenas and boxes with necessay hold fast, nut, bolts and washers, grouting nuts,supporting basement channels duly grouting with existing PCC foundation and welding/jointing and clamping 02 more channels of size 50x50x 5 mm thick join one to another of 03 Nos of pipes 100 mm dia heavy duty of length 4 mtr each to strengthen the structre to hold the equipment and antena complete all as specified and directed. 75 Sub main wiring with 2 runs of 6 sqmm, single core, PVC insulated, unsheathed FRLS, 1100 volts grade, multi stranded with copper conductor drawn through and including suitable size of ERW steel conduit pipe and accessories and one run of 6 sqmm, single core, PVC insulated, unsheathed FRLS, 1100 volts grade, multi stranded with copper conductor for earth continuitycomplete all as specified and as directed. 76 Point wiring with 1100 V grade 1.5 Sqmm single core PVC insulated unsheathed cable, copper conductor multistrandedpassing through and including heavy duty PVC conduit with all accessories, surface type on wall/ roof/ floor with concealed MS box / Surface type MSbox as required at site with laminated top cover duly earthed with 1.5 sqmm multistranded PVC insulated copper conductor cable forone 5 pin switch socket outlet 05 Amps on Independent boardcontrolled by one switch complete all as specified and as directed. 77 S & F wall mounted fan 450mm sweep with three blade and accessories 230 v, 1400 RPM complete all as specified and as directed. Make : Havells model Airboll Hi speed white series FHWABHSWHT18 or equivalent model in Bajaj / Usha / Crompton 78 Supply, install, connect, test and commissioning of inverter type Air conditioner Hi wall comprising of units Indoor & outdoor complete with cordless remote control unit, within built in airioniser, Plasma filter for better indoor air quality, leakage detector etc with minimum 5 star rating and EER 3.2 of capacity 2.0 TR, inclusive of suction and discharge lines of suitable sizeand length of copper tube, necessary brazing and providing nitrile tubing over gas circulating copper tubes and neatly tying the ends with PVC insulating tape and mounting on suitable bracket, suitable drain pipe for disposal of wastewater upto ground level and testing, neatly finishing the disturbed surfaces of walls to match with the surroundings complete all as directed. 79 S & F single pole and neutral enclosure with a twopin and earth plug and socket complete with one MCB SP 20 Amps 240 V completeall as specified and as directed. 80 Supply, install, connect, test and commissioning of voltage stabilizer of 5.0 KVA capacity for automatic operation, single phase naturally air cooled, indoor type & designed for input variation between 170V to 260V with output volatge stabilized at 230V with accuracy of ± 2.5% with high& low voltage cut out & time delay including electric connection complete all as specified and as directed. 81 Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (in vertical position) earth pit not less than 2.25m below normal ground level with the top edge of the earth plate not less than 1.5m (B.G.L.) and connected to galvanized earth lead wire 4mm by means of bolts, nuts, check nuts, and washers of galvanized iron including PCC (1:2:4) type B1 precast RCC cover slab with suitable handle made out of 8 mm dia round bar, including necessary excavation and earth work in any type of soil, 20 mm dia med grade galvanized steel tube for watering with one end fixed with cast iron funnel and wire mesh, 15mm bore light grade galvanized steel tubing for drawing earth lead GI strip protection & common salt, charcoal in alternate layers etc. complete all as shown in EP No 3 of SSR Part 1 and testing on completion complete all as specified and as directed. Note:The GI earth wire and 15 mm dia bore light grade GI pipe upto 7.5 m deemed to be included in the rate quoted by the contractor. 82 Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (in vertical position) earth pit not less than 2.25m below normal ground level with the top edge of the earth plate not less than 1.5m (B.G.L.) and connected to GI earth strip 32X6mm by means of bolts, nuts, check nuts, and washers of galvanized iron including PCC (1:2:4) type B1 precast RCC cover slab with suitable handle made out of 8 mm dia round bar, including necessary excavation and earth work in any type of soil, 20 mm dia med grade galvanized steel tube for watering with one end fixed with cast iron funnel and wire mesh, 40mm bore light grade galvanized steel tubing for drawing earth lead GI strip protection & common salt, charcoal in alternate layers etc. complete all as shown in EP No 3 of SSR Part 1 and testing on completion complete all as specified and as directed. Note:The GI strip and 40 mm dia bore light grade GI pipe upto 7.5 m deemed to be included in the rate quoted by the contractor. 83 Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4mm dia galvanised iron or steel wire complete all as specified and as directed. 84 Copper Strip of size 20x3.0 mm complete including cut to length and size to match the existing system and fixing the same to the wall / roof / terrace laid in suitable size HDPE/PVC conduit along with clamps/saddles along with fixing materials complete all as specified and directed. Note : provision ofearth strips to the technical buildingsof any height(Apprx Upto 35 mtrs height) is deemed to be included in the quoted rate 85 Repair/maintenanceof the exsting earthing to using adequate chamical like mag sulphate, copper sulphate and BFC to obtain desited earth value complete all as specified and directed. 86 M&L forRCC earth pit cover of size 400x400x40mm withPCC 1:3:6 type C-1 using 20mm graded agreegate with necessary form work forexisting earth pitfordifferent locations complete all as specified and directed. 87 Earthing pit display board made out of 3 mm thick MS sheet of size 30 x 35 cm welded to 75 cm long 25 x 25 x5 mm thick MS angle iron grouted in PCC 1:3:6 (using 20 mm graded stone aggregate ) to a depth of 20 cm below GL and including applying two coats of synthetic enamel paint of approved coloured over a coat of red oxide primer on all expoxed steel surface and writing the letters on the plate for showing the following details complete all as specified and directed.(a) Earthing Pit No., (b) Date of Measurement(c) Next Due Date(d) Standard Value 88 Test point terminal block made of heavy duty PVC box and use testing metal as earth strip copper and screwed including 3 nos. 8mm dia 25mm long hex. head screw for testing purpose complete all as specified and directed. 89 Supply, install, connect, test and commissioning of flame proof / weather proof with fire retardant paint split unit indoor and out door complete with cordless remote control unit with in built in air ioniser, Plasma filter for better indoor air quality, leakage detector etc.,of energyefficient rating of capacity 2.0 ton with Eco friendly refrigerant R-32/407/410 A and necessary fixing arrangements for indoor / outdoor such as outdoor stand copper pipe leak detection and rectification after installation and should compliance to CIMFR specifications complete all as specified and as directed. 90 Fixing only split AC out door and indoor unit using necessary indoor unit back plate, outdoor channels, nut,bolt and washers and making necessary electric connection, copper pipes with suitable pipe insulation along with copper nut,bolt and wshers and checking and testing the existing AC unit duly replacing capacitor and filling the refrigentgas make its serviceability complete all as specified and as directed. 91 Supply, install, connect, test and commissioning offlame proof voltage stabilizer of 4.0 KVA capacity for automatic operation, single phase naturally air cooled, indoor type & designed for input variation between 170V to 260V with output volatge stabilized at 230V with accuracy of ± 2.5% with high& low voltage cut out & time delay including electric connection complete all as specified and as directed.

Key Value

Document Fees
INR 500 /-
EMD
INR 90000.0 /-
Tender Value
INR 45 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Notice 0 KB
Click here to download tender document Tender Document 0 KB
Click here to download tender document Tender Document 0 KB
Click here to download tender document Tender Document 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail