}

Tender For Infrastructure Development Of Indumati Market At Bansberia Dist Hooghly, Hooghly-West Bengal

Government Departments has published Tender For Infrastructure Development Of Indumati Market At Bansberia Dist Hooghly. Submission Date for this Tender is 04-10-2024. Uniform Tenders in Hooghly West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

45078152
Tender For Infrastructure Development Of Indumati Market At Bansberia Dist Hooghly
Open Tender
Indian
West Bengal
Hooghly
04-10-2024

Tender Details

Tender For Infrastructure Development Of Indumati Market At Bansberia Dist Hooghly- 1 Civil 2 Dismantling all types of masonry excepting cement concrete plain or reinforced, stacking serviceablematerials at site and removing rubbish as directed within a lead of 75 m. 3 Dismantling all types of plain cement concreteworks, stacking serviceable materials at site andremoving rubbish as directed within a lead of 75m.In ground floor including roof.(a) upto 150 mm. Thick 4 Dismantling R.C. floor, roof, beams etc. Including cutting rods and removing rubbish as directedwithin a lead of 75 m. including stacking of steel bars.(a) In ground floor including roof. 5 Clearing compound premises of shurbs, plants, jungles etc. by cutting and removing as directed (Specific permission of Engineerin-Charge prior to execution will beecessary).(Payment to be made on area cleared) 6 Earth work in excavation of foundation trenches or drains. in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing. Spreading or stacking the spils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches. leveling. dressing and ramming the bottom. bailing out water as required complete 7 Depth of excavation not exceeding 1500mm 8 Depth of excavation for additional depth beyond 1500mm and upto3000 mm. but not requiring shoring 9 Earth work & filling in foundation trences or plinth with good earth in layers not exceeding 150 mm. including watering and raming etc. layer by layer complete.(Payment to be made on basis of measurement of finished quantity of work). 10 With earth obtained from excavation of foundation. 11 Filling in foundation or plinth by silver sand in layers not by thorough saturation with water, ramming completeexceeding 150 mm as directed and consolidating the sameincluding the cost of supply of sand. (Payment to be madeon measurement of finished quantity) (B) Do - by fine sand 12 Pre-constructional antitermite measures :-Anti termite treatment to the top surface of the consolidated earth within plinth walls with chemical emulsion by admixing chloropyrofos emulsifiable concentrates ( 1% concentration) with water by weight at the rate of 5 Litres per sq. m. of the surface before sand bed or sub-grade is laid. Holes upto 50 mm. to 75 mm. deep at 150 mm. centre to centre both ways shall be made with 12 mm, diameter mild steel rod on the surface to facilitate saturation of the soil with the chemical emulsion. The work shall be carried out as per specification described in para 6.4 of code IS-6313 (part -II) 1981. (Mode of measurment will be per Sq.M of plan area of plinth treated.) 13 Anti-termite treatment to the outside of foundations with chemical emulsion by admixing chloropyrofos emulsifiable concentrates (1%concentration) with water by weight including cutting shallow channel by excavating soil along and close to the wall face ensuring uniform dispersal of the chemical emulsion to a depth of 300mm. from the ground level by rodding with 12mm. dia. M.S. rod at 150mm.interval in the channel. 1.75 litres of chemical emulsion per metre length shall be used and a balance quantity of 0.5 litres of the chemical emulsion perrunning metre shall then be used to treat the back fill earth by directing the spray of the imulsion towards the wall surface. The entire work is to be carried out as per specification laid down in para 4.3.1.1 of code IS-6313 (Part-III) 1981. 14 Supplying and laying Polythene Sheet (150gm / Sq.M) over damp proof course or below flooring or roof terracing or in foundation or in foundation trenches. 15 Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints withlocal sand. 16 Cement concrete with graded stone ballast ( 40 mm size excluding shuttering)In ground floor 1:3:6 proportion[Pakur Variety 17 Ordinary cement concrete(mix 1:1.5:3)with graded stone chips(20 mm size ) excluding shuttering and reinforcement if any ifany in ground froor as per relevant Is code . 18 Controlled Cement concrete with well graded stone chips (20 mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 300 Kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. In ground floor and foundation.[using concrete mixture] M 25 GradePakur Variety 19 ground floor 20 1 st Floor 21 2ndFloor 22 Hire and labour charges for shuttering with centering and necessary stagingupto 4 m using approved stout props and thick hard wood planks of approvedthickness with required bracing for concrete slabs, beams and columns,lintels curved or straight including fitting, fixing and striking out aftercompletion of works (upto roof of ground floor)(c) Steel shuttering or 9 to 12 mm thick approved quality ply board shutteringin any concrete work 23 ground floor 24 1 st Floor 25 2nd Floor 26 Reinforcement for reinforced concrete work inthe all sorts of structures including distribution bars, stirrups, binders etc. including supply of rods , initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge balck annealed wire at every intersection, complte as per drawing and directionThormal-Mechanically Treated bars of grade Fe-500D or moreFor Works in Foundation and upto roof of ground floor upto 4m 27 SRMB, ELEGANT STEEL, CAPTAIN,BALAJI SHAKTI,HEXA,RUNGTA STEEL,ADHUNIK,SUPER SHAKTI,SALUJA GOLD,RASHMI TMT,SEL,SEL TIGER 28 Foundation & upto roof of Ground floor / upto 4 M 29 1 st Floor 30 2nd Floor 31 Brick work with 1st class bricks in cement mortar (1:6) 32 In foundation and plinth 33 In superstructure, ground floor 34 1 st Floor 35 2nd Floor 36 125mm thick brick work with 1st class bricks in cement mortar(1:4) in different floors. Inclusive of using approved H.B netting in every third layer . 37 Ground Floor 38 1 st Floor 39 2nd Floor 40 Labour for Chipping of concrete surfacebefore taking up Plastering work. 41 Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course,scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] 42 (2) With 1:6 Cement morter 43 (a) 15 mm thick plaster ( External) 44 (i) Ground Floor 45 1 st Floor 46 2nd Floor 47 (i) With 1:6 cement mortar 48 (b) 20 mm thick plaster( Internal) 49 (i) Ground Floor 50 1 st Floor 51 2nd Floor 52 (i) With 1:4 cement mortar 53 10 mm thick plaster (Ceiling) 54 (i) Ground Floor 55 1 st Floor 56 (2) With 1:4 Cement morter 57 (a) 15 mm thick plaster ( External) 58 Artificial stone in floor, dado, staircase etc with cement concrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners and application of cement slurry before flooring works using cement @ 1.75 kg/sq.m all complete including all materials and labour. In ground floor.3 mm. thick toppingUsing grey cement : 59 (iii) 35 mm. thick 60 Neat cement punning about 1.5mm thick in wall, dado, windowsill, floor etc.NOTE:Cement 0.152 cu.m per100 sq.m. 61 18 mm. to 22 mm. thick, kota stone slab set in 20 mm thick (avg) cement mortar (1:4) in floor, stair & lobby including pointing in cement slurry with admixture of pigment matching the stone shade, including grinding & polishing as per direction of Engineer - in charge to match with the existing work. [Slurry for bedding @ 4.4 kg/Sq.m and pointing @2.0 kg/Sq.m] 62 Extra cost of labour for prefinished and premoulded Nosingto treads of steps, railing, window sill etc. of Kota Stone. 63 Extra cost of labour for grinding Kota Stone Floor in treadsand riser of Steps. 64 Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile &finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by syntheticadhesive & grout materials etc .With Sand Cement Mortar (1:4) 20 mm thick & 2 mm thickcement slurry at back side of tiles using cement @ 2.91Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m.(a) Area of each tile upto 0.09 Sq.m (i) Coloured decorative 65 (A) Floor 66 (B) Wall 67 (b) Rendering the surface of walls and ceiling with white cement based wall putty of approved make and brand(1.5mm thick) 68 Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturers specification and as per direction of theEIC. 69 In Ground Floor: (b) Two Coats 70 1stFloor: (b) Two Coats 71 2ndFloor: (b) Two Coats 72 Applying Interior grade Acrylic Primer of approved quality and brandon plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparingthe surface throughly, complete as per manufacturers specification andas per direction of the EIC. (In Ground Floor) 73 In Ground Floor: (b) Two Coats 74 1stFloor: (b) Two Coats 75 2ndFloor: (b) Two Coats 76 Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturers specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. Therate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer.a) Normal Acrylic Emulsion 77 In Ground floor (Two Coat) 78 1stFloor: (b) Two Coats 79 2ndFloor: (b) Two Coats 80 Acrylic Distemper to interior wall, ceiling with a coat of solvent basedinterior grade acrylic primer (as per manufacturers specification)including cleaning and smoothning of surface.Two Coats 81 In Ground floor (Two Coat) 82 1stFloor: (b) Two Coats 83 2ndFloor: (b) Two Coats 84 (a) Supplying, fitting and fixing steel rolling shutter profile type with 18 B.G . of approved type steel latche section 75mm wide, fitted withcoil wire spring to necessiate the fitting of required Nos. of C.I. Pulleys on heavy type solid drawn seamless steel tube complete withlocking arrangements both inside and outside specially builtup side guide channels including providing a hood for the steel rolling shutter in the room, painting two coats of approved aluminium paint over a coat of red lead primer complete. 85 Collapsible gate with 40mm x 40mm x 6mm Tee as top and bottom guide rail, 20mm x 10mm x 2mm vertical channels 100mm apart infully stretched position 20mm x 5mm M.S. flats as collapsible bracings properly rivetted and washered including 38mm steelrollers including locking arrangements, fitted and fixed in position with lugs set in cement concrete and including cutting necessaryholes, chasing etc. in walls, floors etc. and making good damages complete. 86 (i) Ground Floor 87 1 st Floor 88 2nd Floor 89 Supplying, fitting and fixing Stainless Steel railing consist of 38mm dia and 900mm height vertical balustrade at every two alternative steps, 50mm dia top rail, 3 (three ) nos 19mm dia horizontal Strainless steel pipe and base/cover plate with Strainless Steel GRADE 304 containing 7.5% nickle (Interior Grade) Brushed/Mat finish, complete as per direction of the Engineer-in- charge.Weight of Strainless Steel railing per metre 6.5 Kg (approx) 90 M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor.(i) Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr. 91 (i) Ground Floor 92 (ii) 1stFloor 93 M.S.round or square bar grating of windows wtc. Fitted &fixed in holes of window frame & with intermediate flat bar stiffner ( with necessary holes for the grating bars & with the ends turned & fixed to timber frame with necessary screws ) complete as directed. 94 (i) Ground Floor 95 a) Priming one coat on steel or other metal surface with synthetic oilbound primer of approved quality including smoothening surfaces by sandpapering etc. 96 (A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : 97 (b) On steel or other metal surface : 98 (iv) Two coats (with any shade except white) 99 Supplying, fitting and fixing fibre reinforced polymer (FRP) Composite door frame as per approved section with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to safisfy IS: 4020 door testing performance criteria..66mm x 90mm 100 Supplying, fitting & fixing fibre reinforced polymer (FRP) Composite doorshutters as per approved design with glass fibre reinforced plastic moulded skinsand a special sandwich core, so as to impart monolitaheic composite structure asper approved technology of Department of Science and Technology (DST) tosatisfy IS:4020 door testing performance criteria.In ground floor. (i) 32 mm thick 101 Supplying, fitting & fixing Zn-Al alloy (55% Al & 45% Zn) coating of 150 grams per sq. metre (followed by colour coated on both side) steel sheet work having minimum yieldstrength of 550 Mpa of trapizoidal profile of approved make (excluding the supporting frame work) fitted and fixed with 55 mm & 25 mm self tapping screw, EPDM Washer 16 mm dia & 3 mm th. washer etc. complete with 150 mm end lap and one corrugation minimum side lap. (Payment to be madeon area of finished work). 102 M.S. structural works in roof trusses with tubular sections conforming to IS: 806-1968 & IS: 1161- 1998 cnnected to one another with bracket, gusset cleats as per design, direction ofEngineer-in-charge complete including cutting to requisite size, fabrication with necessary metal arc welding conforming to IS: 816-1969 & IS: 9595 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete.The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour reqired for the work including all incidental chages such as electricity charges, labour insurance charges etc. Payment to be made on the basis of calculated weight of structural tubular memebrs as specified in relevent IS code in finished work. Payment for gusset, bracket, cleat may be made by adding the actual weight of such items with weight of finished structural members. The rates are considered for a height of erection 8 m. / 2nd floor level from the ground. Add 1.5 % extra over the rate for each additional floor or 4m. beyond the initial 8 m. or part thereof.i) For trusses spanning up to 12.00 m 103 Supplying,Fitting & Fixing UPVC pipes A- Type and fittings confirming to IS : 13592 - 1992 with all necessary clamps nails,including making holes in wall, Floor etc. cutting trenches in any soil through masonry concrete structures etc. if necessary and mending good damags including joining with jointing materials (Spun Yarn,Valamoid/Bitumen/M-Seal etc.)Complete. 104 A) UPVC Pipes 105 (ii) 110 mm dia 106 © Bend 87.5 degree 107 (ii) 110 mm dia 108 (d) Shoe 109 (ii) 110 mm dia 110 25mm. thick damp proof course with cement concrete with stone chips (1:1.5:3) [with graded stone aggregate 10 mm nominal size] and admixture of water proofing compound asper manufacturers specification followed by two coat of polymer based paint, (1st coat after 4 to 5 days of concrete laying and 2 nd coat just before brick masonry work) asdirected (cost of water proofing compound & polymer based paint to be paid separately).( Chequering not required over concrete or painted surface).[Note: - Waterproofing as per item 9, polymer based paint asper item 8 (a) of subhead C of Section (C). 111 Supplying best Indian sheet glass panes set in putty and fitted and fixedwith nails and putty complete. (In all floors for internal wall & upto 6m height for external wall)(i) 3 mm thick (weighing 7.4 kg/Sq.m) 112 Supplying & laying 3mm thick pre-fabricated plastomeric water proofing membrane conforming to EN 12311-1 & ASTMD 5147, manufactured with atactic poly propylene(APP) modified premium grade asphalt , specially reinforced with non-woven polyester core with polyester reinforcement@160 gms per sqm & both faces covered with thermo-fusible polyethylene film /MineraL on top face over a coat of primer @ 0.40 lit/sqm of manufacturers specification onsmooth,clean dry surface prepared wherever required.Lap joint shall be provided of 75 mm in longitudinal & 100 mm intransverse direction and fused using LPG/ Propane torch employing extra care ensuring full bondage, complete removal of entrapped air and sealing edges into grooves inappropriate manner as per direction of Engineer -in-charge all complete including materials,labour and applicable taxes. (Payment shall be made on the basis of finished surface area.). Membrane Property: Softening Point > 150 deg C, Cold Flexibility < -6 deg C, Tensile Strength, N/cm : 600(longitudinal), 450 (transverse), Tearing Strength, N: 300 (longitudinal), 200 (transverse) 113 Sanitary & Plumbing 114 Supplying, fitting and fixing PVC pipes of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew,reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paintin any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting willbe made seperately) 115 20 mm 116 25 mm 117 32 mm 118 40 mm 119 Supplying, fitting and fixing 10 litre porcelain low-down cistern ofapproved make with either side or bottom inlet, side overflow, bracketscomplete with all internnal PVC fittings.White 120 Supplying P.V.C. water storage tank of approved quality with closed topwith lid (Black) - Multilayer(c) 1500 litre capacity 121 Labour for hoisting plastic water storage tank.(i) Upto 1500 litre capacity. 122 Wash basin vitreous china of approved make (without fittings)supplied,fitted and fixed in position on 75mm X 75 mm X 75 mm woodblocks and C.I. brackets including two coats of painting of C.I. brackets.(iii) 630 mm X 450 mm size 123 Supplying, fitting and fixing bib cock or stop cock.(ii) Chromium plated Bib Cock long body with wall flange with aerator(Equivalent to Code No. 512 & Model - Tropical / Sumthing Special ofESSCO or similar brand) 124 Supplying,fitting and fixing approved brand P.V.C. CONNECTOR whiteflexible, with both ends coupling with heavy brass C.P. nut, 15 mm dia.(iii) 600 mm long 125 Supplying,fitting and fixing approved brand 32 mm dia.P.V.C. waste pipe,with PVC coupling at one end fitted with necessary clamps. 126 Supplying, fitting and fixing complete Bottle waste trap (Heavy Quality)(a) Chromium plated Bottle trap 32 mm with 190 mm long connecting pipeand wall flange (Equivalent to Code No. 545 & Model - Tropical /Sumthing Special of ESSCO or similar brand). 127 Supplying, fitting and fixing pillar cock of approved make.a) (i) CP Pillar Cock - 15 mm. (Equivalent to Code No. 507 & Model -Tropical / Sumthing Special of ESSCO or similar brand). 128 Supplying, fitting and fixing E.W.C. in white glazed vitreous chinaware of approved make complete in position with necessary bolts, nuts, etc.(a) With P trap 129 Supplying, fitting and fixing E.W.C. in white glazed vitreous chinaware of approved make complete in position with necessary bolts, nuts, etc.(b) With S trap 130 Electrical 131 Fixing only single/twin florescent light fitting complete with all accessories Directly on wall/ceiling with HW block and suitable size MS fastener, Ceiling plate, nipples etc. as required 132 Supply & Fixing 240 V, 2 nos. 6A, & 2 nos. 20A plug socket with separate 2 nos. 6 A & 2 nos. 20A Piano key type switch, indicator & 20A switch type SP MCB (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 240x200x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required 133 Supplying and Drawing 1.1 KV single core stranded FR PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required 134 2x36/0.3 (2.5 sqmm) + 1x22/0.3 (1.5 sqmm) as ECC 135 2x84/0.3 (6 sqmm) + 1x56/0.3 (4 sqmm) as ECC 136 Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded FR PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to light/fan/call bell points with Piano key type switch (Anchor make) fixed on sheet metal (16 SWG) switch board with bakelite/perspex (wall matching colour) top cover (3 mm thick) flushed in wall incl. mending good damages to original finish(2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC) 137 Average run 9 mtr 138 Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded FR PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit FR (Precision make), with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm)single core stranded FR PVC insulated & unsheathed copper wire as ECC, to 5A 3 pin flush type plug socket & Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall incl. bakelite/Perspex (wall matching color) top cover 3 mm thick and incl. painting the MS box and mending good the damages to original finish 139 On Board 140 Supplying & Fixing of Box type fan clamp of 150mm dia & 80mm depth made of 16 SWG CRCA sheet with one end duly sealed by cover, properly welded, incl. S&F 12mm dia 600mm long MS rod duly bent by heat treatment at the centre position of rod to grip fan bobbin properly, incl. binding the rod and fan box with reinforcement by 22 SWG steel binding wire, incl. supplying & covering the box with alkathene sheet, placed in order to prevent concrete from entering the box. 141 Supplying and fixing 415V, TPN SFU with sheet steel enclosure on flat iron/angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating. (All L&T make) 142 63 AMP 143 Supplying & fixing sheet metal (16 SWG) Iron Clad Busbar chambers on angle iron frame on wall, incl. earthing attachment and painting as required ( Alluminiuam). 144 4 bars,415 V, 100/125 A Dimension of Al. bars [85mm long] Dimension of Sheet Metal Box.300x150mm 145 Supplying and fixing 2 WayMCB SS enclosure with IP-20/30 protection, powder coated provision for two/four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment 146 Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthingattachment. 147 2+6 way 148 Supplying and fixing 240V MCB Isolator on din rail of existing DBs and necessary connection. 149 40 Amp 150 Supplying and fixing 6-32 A 240 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection 151 Excavation of soil for installation of Earth Electrode and filling & ramming for soft Soil. 152 Earthing with 50mm dia G.I. pipe (TATA-M) 3.64mm thick * 3.04 Mtrs. Long and 1*4 WG wire (4 Mtr. Long) 13mm dia * 80mm long G.I. bolts double washers incl. S&F dia pipe protection (1Mtr long) to be filled with bitumen partly under the G.L. and partly above G.L. driven to an average depth of 3.65Mtrs .below the G.L. and restoring the surface duly remmed 153 Extra treatment of soil by using salt and charcoal for pipe electrode as required. 154 Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe 155 Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 50 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete withGI bolts, nuts, washers, spacing insulators etc. as required 156 Connecting the equipments to early busbar incl. S&F No. 8 SWG G.I. wire onwall /floor with stapels as per G.S. 157 Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required 158 32 mm dia 159 Ground Floor Common Passage 35 nos Platfrom 160 Fixing only starters (for motor control) on flat iron frame / angle iron frame on wall.On flat ironframe (for lower rating) 161 Direct on Line starter for motor (upto 5 HP) 162 Fixing only single/twin florescent light fitting complete with all accessories Directly on wall/ceiling with HW block and suitable size MS fastener, Ceiling plate, nipples etc. as required 163 Supply & Fixing 240 V, 2 nos. 6A, & 2 nos. 20A plug socket with separate 2 nos. 6 A & 2 nos. 20A Piano key type switch, indicator & 20A switch type SP MCB (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 240x200x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required 164 Supplying and Drawing 1.1 KV single core stranded FR PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required 165 2x36/0.3 (2.5 sqmm) + 1x22/0.3 (1.5 sqmm) as ECC 166 2x56/0.3 (4 sqmm) + 1x36/0.3 (2.5 sqmm) as ECC 167 2x84/0.3 (6 sqmm) + 1x56/0.3 (4 sqmm) as ECC 168 Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded FR PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to light/fan/call bell points with Piano key type switch (Anchor make) fixed on sheet metal (16 SWG) switch board with bakelite/perspex (wall matching colour) top cover (3 mm thick) flushed in wall incl. mending good damages to original finish(2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC) 169 Average run 9 mtr 170 Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded FR PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit FR (Precision make), with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm)single core stranded FR PVC insulated & unsheathed copper wire as ECC, to 5A 3 pin flush type plug socket & Piano Keytype switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall incl. bakelite/Perspex (wall matching color) top cover 3 mm thick and incl. painting the MS box and mending good the damages to original finish 171 On Board 172 Supplying and fixing 415V, TPN SFU with sheet steel enclosure on flat iron/angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating. (All L&T make) 173 100AMP 174 Supplying & fixing sheet metal (16 SWG) Iron Clad Busbar chambers on angle iron frame on wall, incl. earthing attachment and painting as required ( Alluminiuam). 175 4 bars,415 V, 200 A Dimension of Al. bars [85mm long] Dimension of Sheet Metal Box.300x150mm 176 Supplying & Fixing of Box type fan clamp of 150mm dia & 80mm depth made of 16 SWG CRCA sheet with one end duly sealed by cover, properly welded, incl. S&F 12mm dia 600mm long MS rod duly bent by heat treatment at the centre position of rod to grip fan bobbin properly, incl. binding the rod and fan box with reinforcement by 22 SWG steel binding wire, incl. supplying & covering the box with alkathene sheet, placed in order to prevent concrete from entering the box. 177 Supplying and fixing 240/415 V 63 Amp MCB Isolator ondin rail of existing DBs and necessary connection. 178 Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment ( Make: L&T) 179 4 way Enclosure (LTTD04N) 180 Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthingattachment. 181 2+6 way 182 Supplying and fixing 240V MCB Isolator on din rail of existing DBs and necessary connection. 183 40 Amp 184 Supplying and fixing 6-32 A 240 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection 185 Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter: 23 cm (9) 186 Supply & Fixing louver shutter on wall with necy. bolts & nuts (6 mm dia x 62 mm long) For Al 187 30 cm Exhaust fan (12) 188 Excavation of soil for installation of Earth Electrode and filling & ramming for soft Soil. 189 Earthing with 50mm dia G.I. pipe (TATA-M) 3.64mm thick * 3.04 Mtrs. Long and 1*4 WG wire (4 Mtr. Long) 13mm dia * 80mm long G.I. bolts double washers incl. S&F dia pipe protection (1Mtr long) to be filled with bitumen partly under the G.L. and partly above G.L. driven to an average depth of 3.65Mtrs .below the G.L. and restoring the surface duly remmed 190 Extra treatment of soil by using salt and charcoal for pipe electrode as required. 191 Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe 192 Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 50 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete withGI bolts, nuts, washers, spacing insulators etc. as required 193 Connecting the equipments to early busbar incl. S&F No. 8 SWG G.I. wire onwall /floor with stapels as per G.S. 194 M.S. structural works in columns, beams etc. with simple rolled structural members (e.g. joists, angle, channel sections conforming to IS: 226, IS: 808 & SP (6)- 1964 connected to one another with bracket, gussets, cleats as per design, direction of Engineer-incharge complete including cutting to requisite shape and length, fabrication with necessary bolting, metal arc welding conforming to IS: 816- 1969 & IS: 1995 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour required for the work including all incidental chages such as electricity charges, labour insurance charges etc.I) For structural members of specified sections weighing less than 22.5 Kg./m.Supplying, fitting and fixing boiling water resistant ply conforming to IS: 303- 1989 bonded with phenol formaldehyde synthetic resin of approved make and brand fitted and fixed as per design as per approval and direction of Engineer-in- Charge.[excluding the cost of supporting frame work and teak wood batten/Lipping] In Ground Floor ( Size 1mtr x1mtr) 195 Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required 196 32 mm dia 197 Laying of cable as below, after cutting floor/pavement/wall/ and making holes incl., embedding the cable at an average depth as below and mending good the damages to original finish incl. removing the rubbish 198 From 2.5 sqmm to 35 sqmm at an average depth of 75 mm in floor/pavement/wall etc. 199 Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below 200 For 4 core 201 upto 16 sqmm 202 Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials 203 4 core16 sqmm cable 204 First Floor 205 Fixing only single/twin florescent light fitting complete with all accessories Directly on wall/ceiling with HW block and suitable size MS fastener, Ceiling plate, nipples etc. as required 206 Supply & Fixing 240 V, 2 nos. 6A, & 2 nos. 20A plug socket with separate 2 nos. 6 A & 2 nos. 20A Piano key type switch, indicator & 20A switch type SP MCB (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 240x200x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required 207 Supplying and Drawing 1.1 KV single core stranded FR PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required 208 2x36/0.3 (2.5 sqmm) + 1x22/0.3 (1.5 sqmm) as ECC 209 2x56/0.3 (4 sqmm) + 1x36/0.3 (2.5 sqmm) as ECC 210 3x80/0.4 (10 sqmm) + 2x84/0.3 (6 sqmm) as ECC 211 Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded FR PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to light/fan/call bell points with Piano key type switch (Anchor make) fixed on sheet metal (16 SWG) switch board with bakelite/perspex (wall matching colour) top cover (3 mm thick) flushed in wall incl. mending good damages to original finish(2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC) 212 Average run 9 mtr 213 Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded FR PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit FR (Precision make), with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm)single core stranded FR PVC insulated & unsheathed copper wire as ECC, to 5A 3 pin flush type plug socket & Piano Keytype switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall incl. bakelite/Perspex (wall matching color) top cover 3 mm thick and incl. painting the MS box and mending good the damages to original finish 214 On Board 215 Supply & Fixing 240 V, 25A Modular type socket, 25 A, Modular type starter (Brand approved by EIC) with 25A Modular switch type DP MCB (C-Curve) and 6 Module GI Modular type switch board with 6 Module top cover plate flushed in wall incl. S&F switch board and cover plate andmaking necy. connections with PVC Cu wire and earth continuity wire etc. 216 Supplying & Fixing of Box type fan clamp of 150mm dia & 80mm depth made of 16 SWG CRCA sheet with one end duly sealed by cover, properly welded, incl. S&F 12mm dia 600mm long MS rod duly bent by heat treatment at the centre position of rod to grip fan bobbin properly, incl. binding the rod and fan box with reinforcement by 22 SWG steel binding wire, incl. supplying & covering the box with alkathene sheet, placed in order to prevent concrete from entering the box. 217 Supplying and fixing 415V, TPN SFU with sheet steel enclosure on flat iron/angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating. (All L&T make) 218 125AMP 219 Supplying & fixing sheet metal (16 SWG) Iron Clad Busbar chambers on angle iron frame on wall, incl. earthing attachment and painting as required ( Alluminiuam). 220 4 bars,415 V, 200 A Dimension of Al. bars [85mm long] Dimension of Sheet Metal Box.300x150mm 221 Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthingattachment. 222 2+6 way 223 Supplying and fixing 240V MCB Isolator on din rail of existing DBs and necessary connection. 224 40 Amp 225 Supplying and fixing 2 WayMCB SS enclosure with IP-20/30 protection, powder coated provision for two/four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment 226 Supplying and fixing 240/415 V 63 Amp MCB Isolator ondin rail of existing DBs and necessary connection. 227 Supplying and fixing 6-32 A 240 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection 228 Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment ( Make: L&T) 229 4 way Enclosure (LTTD04N) 230 Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter: 23 cm (9) 231 Supply & Fixing louver shutter on wall with necy. bolts & nuts (6 mm dia x 62 mm long) For Al .30 cm Exhaust fan (12) 232 Excavation of soil for installation of Earth Electrode and filling & ramming for soft Soil. 233 Earthing with 50mm dia G.I. pipe (TATA-M) 3.64mm thick * 3.04 Mtrs. Long and 1*4 WG wire (4 Mtr. Long) 13mm dia * 80mm long G.I. bolts double washers incl. S&F dia pipe protection (1Mtr long) to be filled with bitumen partly under the G.L. and partly above G.L. driven to an average depth of 3.65Mtrs .below the G.L. and restoring the surface duly remmed 234 Extra treatment of soil by using salt and charcoal for pipe electrode as required. 235 Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe 236 Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 50 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete withGI bolts, nuts, washers, spacing insulators etc. as required 237 Connecting the equipments to early busbar incl. S&F No. 8 SWG G.I. wire onwall /floor with stapels as per G.S. 238 Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required 239 32 mm dia 240 Laying of cable as below, after cutting floor/pavement/wall/ and making holes incl., embedding the cable at an average depth as below and mending good the damages to original finish incl. removing the rubbish 241 From 2.5 sqmm to 35 sqmm at an average depth of 75 mm in floor/pavement/wall etc. 242 Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below 243 For 4 core 244 upto 35 sqmm 245 upto 16 sqmm 246 Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials 247 3½ core 35 sqmm cable 248 4 core16 sqmm cable 249 Laying on Pole with Clamps, Fixing of Cable along the lenth of O.H. pole incl. S & F MS pole clamps fabricated from 25 mm x 6 mm MS flat incl. painting 250 Non Schedule Items 251 Supply of 40 watt TRIMLINEis a robust and high performance batten. This LED luminairecomprises of extruded channel in thermally conductive material.High translucent serrated milky white diffuser is used to get glarefree and smooth light distribution. Efficacy : 100 lumen/watt Model No.CCS-100-40-40-SL-DP-NWH 252 Supply of 10 Watt STUD Compact modern Design utility bulkhead with high energy savings.Model No.LBHP-10-CDL 253 Supply of45 watt FREEDOM NEO LED streetlight made up of pressure die cast housingwith toughened glass and high power LEDs with secondary optics with IP65 protection. External SPD can be ordered separately. Efficacy ≥ 110LPW. Model No.LSTS-45-CDL-M 254 Supply of 240V 300 mm(1400 RPM) heavy duty exhaust fan. Color-Grey)(Make: Orient ) 255 Supplying of one no 4 core 16 sqmm Alluminiuam armoured cable. 256 Supplying of one no 4 core 35 sqmm Alluminiuam armoured cable. 257 Laying of cable as below, after cutting floor/pavement/wall/ and making holes incl., embedding the cable at an average depth as below and mending good the damages to original finish incl. removing the rubbish.From 2.5 sqmm to 35 sqmm at an average depth of 75 mm in floor/pavement/wall etc. 258 Supplying, Installation and commissioning of 5HP capacity Submersiable Pump Mortor set of following specification , Model No - CORA 18C/12G+UMAI100-3.7/22 2.5 SQMM](Make: KSB or equivalent) [A] including supplying and fixing of necessary flat cable, and25 mm dia GI pipe for hanging of the said pumpPWD 2017 PAGE NO F-6/11. the above items is including supplying and ficing of necessary accessrioes and connection complete in all respect. 259 Supply of5 HP DOL Starter. Model No-IHADOAJ1*Make-Havells or equivalent. 260 Supply of 2 Core 4 Sq mm Alluminium XLPE /PVC Armoured cable for 16 A DP main switch to Out side DP Main Switch and Out Side DP Main Switch to Different Wall Bracket Light Point. 261 Laying of cable2 core 4 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting 262 Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables of 2 core 4 sqmm 263 Finishing the end of 2 core 4 sqmm XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials 264 Supplying & Fixing GI waterproof type looping cable box size 200x150x100 mm deep having 4 mm thick comprising of one 250 V 15 A kit-kat fuse unit, one NL on porcelain insulator, one compression type brass cable gland for upto 2- core 16 sqmm PVC/A cable and having lined with rubber gasketted GI top cover with brass machine screws etc., earthing terminal with lug, on steel tubular pole near base, including S&F 40x6 mm thick, MS clamp with bolts, nuts etc. including painting with anticorrosive paint 265 Supplying & Fixing CRC sheet metal (16 SWG) JB-cum- Switch Board of the following sizes complete with three no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. bakelite / Perspex/coloured Perspex (wall matching colour) top cover 3 mm thick flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works. Supply & Fixing 240 V 16A Piano key type switch (Brand approved by EIC) on existing sheet metal switch board having bakelite/perspex top cover by screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required 266 Fixing only outdoor / street light type fluorescent light fitting or MV light fitting complete with all accessories to be fixed /projected from the wall of the building incl. making holes/providing clamping arrangement & necy. GI reducer as required. S&F 40 mm GI pipe (ISI-Medium) quality 1.5 mts. average length having suitable bend S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall incl. painting etc. 267 GST @18% 268 labour welfare cess @ 1% 269 Service Connection Charges by WBSEDCL

Key Value

Document Fees
INR 10000 /-
EMD
INR 403324.0 /-
Tender Value
INR 2.01 Crore /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail