| 1 | xx |
| 2 | Wiring for light point/ fan point/ exhaust fan point/ call bell pointwith 1.5 sq.mm FRLS PVC insulated copper conductor singlecore cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthingthe point with 1.5 sq.mm FRLS PVC insulated copper conductorsingle core cable etc. as required.Group C |
| 3 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, singlecore cable in surface/ recessed medium class PVC conduit as required. Make-L&T/Finolex/Polycab2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 4 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 5 | 2 X6sq. mm + 1 X 6 sq. mm earth wire |
| 6 | 4 X6sq. mm + 2 X 6 sq. mm earth wire |
| 7 | 4 X 10sq. mm + 2 X 6 sq. mm earth wire |
| 8 | Supplying and fixing suitable size GI/PVC box with modular plate and cover in front on surface or in recess, including providing and fixing . 3 pin 5/6 A modular socket outlet and . 5/6 A modular switch, connections etc. as required |
| 9 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.Make-L&T/LEGRAND/ABB |
| 10 | Supplying & fixing suitable size GI/PVC box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, “C” curve including connections, painting etc. as required. Make-L&T/LEGRAND/ABB |
| 11 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole Make L&T/ABB/C&S/Legrand/Hagger/Seimens/Schneider |
| 12 | Double Pole |
| 13 | Triple Pole MCB Make-L&T/ABB/C&S/Legrand/Hagger/Seimens/Schneider |
| 14 | FP MCB 40/63 A Make-L&T/ABB/C&S/Legrand/Hagger/Seimens/Schneider |
| 15 | 4 Way Enclosure Metal Box |
| 16 | 2 Way Enclosure Metal Box |
| 17 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)4 way, Double door |
| 18 | 8 way (4 + 24), Double door |
| 19 | Supplying and fixing following way, type singlepole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)6 way, Double door |
| 20 | 12 way, Double door |
| 21 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required. |
| 22 | Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. |
| 23 | Providng and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing along with exixting surface/recessed conduit/submain wiring/cable as required. |
| 24 | Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt) as required |
| 25 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 meter below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50 mm) |
| 26 | Supplying and fixing of 230VAC 1Ph.300 mm ,900 rpm Wall Fan Make-ORIENT/CG/USHA/Bajaj |
| 27 | Supplying and fixing of 230VAC 1Ph. 1400mm dia Ceiling Fan (High Speed).(Make: Usha / Crompton / Bajaj ) |
| 28 | Supplying and fixing of 230VAC 1Ph.Two module steeped type fan electronic regulatorMake-L&T/LEGRAND/ABB |
| 29 | Supplying,Cutting of hook , painting and fixing ofMS Down rod conduit pipe forinstallation of ceiling fan upto 5 to 8 feet |
| 30 | Supplying and fixing of 230VAC 1Ph. 300 mm exhaust Fanwith sweep feature.Make: Usha / Crompton / Orient |
| 31 | Supplying and fixing of 230VAC 1Ph. Mirrar light . ( Make: Usha / ORIENT / CG) |
| 32 | Supplying ,fixing Connecting & Testing ,20W LED batten Make-Philipse/Syska/Wipro/CG |
| 33 | Supplying Installation, testing and commisioning of following Energy Efficieny recess mounted LED Luminarie suitable for 36w,2X2 Grid Ceiling having flat diffuser & constant current electronic driver complete with all accessories & lampsincluding making hanging arrangement using chain etc. and connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc as reqd. (Make Philips Cat No-(Make Philips Cat No-RC375B LED 365 865/840 PSU W60L60 52 WH/ Equivaent inWipro)Make-Phillipse/Wipro/CG/Polycab |
| 34 | Repairing of existing old wiring/ board/main switch any loose electrical system ,Shadeling of cable andDismentaling of old unused electrical installation as per the site requirenmen and engineer incharge instructions. |