Annual Maintenance Contract Work Of Of 33/11 Kv Substations Under Ee,Edd, Bbk 1St , Barabanki., barabanki-Uttar Pradesh

Boards / Undertakings / PSU has published Annual Maintenance Contract Work Of Of 33/11 Kv Substations Under Ee,Edd, Bbk 1St , Barabanki.. Submission Date for this Tender is 10-09-2024. Clamps Tenders in barabanki Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

45073330
Annual Maintenance Contract Work Of Of 33/11 Kv Substations Under Ee,Edd, Bbk 1St , Barabanki.
Open Tender
Indian
Uttar Pradesh
Barabanki
10-09-2024

Tender Details

Annual maintenance contract Work Of Of 33/11 Kv Substations Under Ee,Edd, Bbk 1St , Barabanki. PROVIDING AND REPLACEMENT OF KV CT 600/300/5 As per RESSPO Norms. (Make GCL, BHEL, SCHEMER, L&T TOSIBA, STEL ETC. 2 PROVIDING AND REPLACEMENT OF KV CT 400/200/5 As per RESSPO Norms. (Make GCL, BHEL, SCHEMER, L&T TOSIBA, STEL ETC. 3 PROVIDING AND REPLACEMENT OF KV CT 300/150/5 As per RESSPO Norms. (Make GCL, BHEL, SCHEMER, L&T TOSIBA, STEL ETC. 4 REPLACEMENT OF DEFECTIVE 11 KV POTENTIALTRANSFORMER 5 SUPPLY & REPLACEMENTOF DEFECTIVE 11 KV PANELO/C + E/F IDMT Relay WITH RETROFITTING ARRANGEMENT 6 SUPPLY & REPLACEMENT OF DEFECTIVE 11 KV PANEL MASTER RELAY WITH RETROFITTING ARRANGEMENT 7 REPLACEMENT & SUPPLY OF DEFECTIVE HT HRC FUSE FOR PT OF APPROPRIATE RATING 8 SERVICING AND REPAIRING OF MECHANICAL SYSTEM FOR PROPER OPENING, CLOSING & TRIPPING OF 11 KV BREAKER WARRANTY PERIOD WILL BE SIX MONTH 9 REPLACEMENT AND SUPPLY OF 11 KV VCB CHARGING MOTOR OF APPROPRIATE RATING 10 REPLACEMENT AND SUPPLY OF DEFECTIVE/BURNT MCB OF APPROPRIATE RATING 11 REPLACEMENT AND SUPPLY OF DEFECTIVE/BURNT AUXILLARY SWITCH OF APPROPRIATE RATING 12 REPLACEMENT AND SUPPLY OF DEFECTIVE ANTIPUMPING RELAY 13 REPLACEMENT AND SUPPLY OF DEFECTIVE SPOUT 14 REPLACEMENT AND SUPPLY OF DEFECTIVE JAW (MALE/FEMALE) FOR 11 KV VCB TROLLEY 15 REPLACEMENT& SUPPLY OF DEFECTIVE INDICATOR 16 REPLACMENT & SUPPLY OF DEFECTIVE AMPERE METER 17 REPLACMENT & SUPPLY OF DEFECTIVE VOLT METER 18 REPLACMENT & SUPPLY OF DEFECTIVE TNC SWITCH 19 REPLACMENT & SUPPLY OF DEFECTIVE LOCAL /REMOTE SWITCH 20 REPLACMENT & SUPPLY OF DEFECTIVE BUZZER 21 REPLACEMENT & SUPPLY OFDEFECTIVECLOSING COIL (24 V D.C) 22 REPLACEMENT & SUPPLY OF DEFECTIVE TNC SWITCH 23 SERVCING AND REPAIRING OF ELECTRICAL SYSTEM FOR PROPER METERING, OPENING, CLOSING & TRIPPING OF 11 KV BREAKER INCLUDING PROVIDING OF NECESSARY INTERNAL WIRING, LUGS, FERRULES OF APPROPRIATE RATING AND COLOUR CODING AND OTHER NECESSARY ACCESSORIES. BATTRERY AND BATTERY CHARGER OVERHAULING & MAINTENANCE. WARRANTY PERIOD SIX MONTH 24 IN CASE OF EMERGENCY BREAKDOWN VCB REPAIRING ETC WORK LINE CLEANING AND FEFITTING AFTER REMOVAL OF FAULT WITH IN 1 HOUR AFTER GETTING INFORMATION AND WARRANTY PERIOD WILL BE SIX MONTH 25 PROVIDING AND ERRECTION OF PIPE EARTHING VIA 2 INCH DIA GI PIPE (3MM) UPTO 40 FEET 26 The work of safe carriage of the following material from Electricity store center Barabanki to work siteunder the jurisdiction of EDD-I Barabanki Approx. distance upto 30 Km. Including safe loading and unloading. 27 33 KV O/D VCB 1250 A 28 ACSR DOG CONDUCTOR 29 LINE ISOLATOR 800A 30 33 KV CURRENT TRANSFORMER 400/200/1 OR 200/100/1 31 11 KV POTENTIALTRANSFORMER 32 11 KV CAT-A ENERGYMETER 33 ERECTIONWORK 34 INSTALLATION OF 33 KV O/D VCB 1250 A 35 ACSR DOG CONDUCTOR 36 INSTALLATION OF New 33 Kv CONTROL PANEL 37 INSTALLATION OF 33 KV line isolator 33 KV (800 Amp.) 38 REPLACEMENTOF DEFECTIVE 33 KV CURRENT TRANSFORMER 400/200/1 39 SUPPLY & REPLACEMENTOF DEFECTIVE 33 KV PANELO/C + E/F IDMT Relay WITH RETROFITTING ARRANGEMENT 40 SUPPLY & REPLACEMENT OF DEFECTIVE 33 KV PANEL MASTER RELAY WITH RETROFITTING ARRANGEMENT 41 SUPPLY & REPLACEMENT OF DEFECTIVE 33 KV PANEL AUXILARY Relay WITH RETROFITTING ARRANGEMENT 42 REPLACEMENT & Supply OFDEFECTIVECLOSING COIL 43 REPLACEMENT & SUPPLY OFDEFECTIVETRIPPING COIL 44 REPLACEMENT & SUPPLY OF DEFECTIVE MAIN CONTACT BLOCK OF BREAKER 45 REPLACEMENT & SUPPLY OF DEFECTIVE TNC SWITCH 46 REPLACEMENTOF DEFECTIVE CONTROL CABLEFORM PANEL TO VCB 2*2.5 SQ MMARMOURED CABLE 47 REPLACEMENT OF DEFECTIVE CONTROL CABLEFORM PANEL TO VCB 4*2.5SQ MM ARMOURED CABLE 48 REPLACEMENT AND SUPPLY OF VCB CHARGING MOTOR OF APPROPRIATE RATING 49 REPLACEMENT AND SUPPLY OF DEFECTIVE/BURNT MCB OF APPROPRIATE RATING 50 REPLACEMENT AND SUPPLY OF DEFECTIVE/BURNT AUXILLARY SWITCH OF APPROPRIATE RATING 51 REPLACEMENT AND SUPPLY OF DEFECTIVE ANTIPUMPING RELAY 52 REPLACEMENT& SUPPLY OF DEFECTIVELED INDICATOR 53 REPLACMENT & SUPPLY OF DEFECTIVE AMPERE METER 54 REPLACMENT & SUPPLY OF DEFECTIVE VOLT METER 55 REPLACMENT & SUPPLY OF DEFECTIVE LOCAL /REMOTE SWITCH 56 REPLACMENT & SUPPLY OF DEFECTIVE BUZZER 57 REPLACEMENT & SUPPLY OF DEFECTIVE WTI of Power T/F 58 REPLACEMENT & SUPPLY OF DEFECTIVE OTI of Power T/F 59 REPLACEMENT & SUPPLY OF DEFECTIVE MAGNETIC OIL GAUGE OF POWER TF 60 REPLACEMENT & SUPPLY OF DEFECTIVE BUCHOLTZ RELAY 61 REPLACEMENT & SUPPLY OF DEFECTIVE MAIN CONTACT BLOCK OF TRANSFORMER 62 SUPPLY AND ERRECTION OF SILICA GEL BREATHER COMPLETE FOR 10 MVA T/F. ALL REQUIRED MATERIAL WILL BE PROVIDED BY CONTRACTOR 63 SUPPLY AND ERRECTION OF ARCHING HORN. ALL MATERIAL WILL BE PROVIDED BY CONTRACTOR. 64 SUPPLY AND ERRECTION OF COPPERMESS FOR 11 KV SIDE CONNECTION NEUTRAL. ALL MATERIAL WILL BE PROVIDED BY CONTRACTOR 65 REPLACEMENT AND SUPPLY OF DEFECTIVE BREATHER WITH SILICA GEL 66 SERVICING OF ELECTRICAL SYSTEM FOR PROPER OPENING, CLOSING & TRIPPING OF 33 KV BREAKERS INCLUDING PROVIDING NECESSARY INTERNAL WIRING, LUGS, FERRULES OF APPROPRIATE RATING AND COLOUR CODING& SERVICING MECHANICAL SYSTEM FOR PROPER OPENING, CLOSING & TRIPPING OF 33 KV BREAKERS & SERVICING 33 KV PANEL FOR PROPER OPERATION OF OPENING, CLOSING, TRIPPING, ALARM, INDICATION OF BREAKER INCLUDING PROPER INTERNAL WIRING OF PANELS AND PROPER WIRING BETWEEN PANELS, DC CHARGER, 33 KV BREAKER, 33 KV CTs, 33 KV PTs, POWER TRANSFORMER OIL TEMPRATURE INDICATOR, WINDING TEMPRATUREINDICATOR, OIL LEVEL INDICATOR, BUCHOLTZ RELAY ETC WITH PROPER CONTOL CABLE, LUGS, FERRULES OF APPROPRIATE RATING AND COLOUR. MAINTENANCE OF LIGHTING ARRANGEMENT IN SWITCHYARD & CONTROL ROOM ALSO AND OTHER IMPORTANT WORKS RELATED TO 33/11KV SUBSTAION, WARRANTY WILL BE SIX MONTH. 67 SUPPLY AND REPLACEMENT OF DAMAGED HEAVY DUTY PANTHER CONDUCTOR/ PG CLAMP IN SWITCH YARD 68 SUPPLY AND REPLACEMENT OF DAMAGED ISOLATOR JAW IN COMPLETE 69 RECTIFICATION OF POWER T/F LEAKAGE 70 Centifusing of 10 MVA T/F 71 Centifusing of 5 MVA T/F 72 Painting of All stracture of swicht yard such as terminal gantry, Bus gantry, Line Isolator, Bus Isolators, Fuse sets, CT Stractures, Breaker Stractures, LA Stractures, power transformer ((spray painting) Etc with one code of red oxide and two cote of Almuniam paint

Key Value

Document Fees
INR 3540 /-
EMD
INR 50000.0 /-
Tender Value
INR 50 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail