}

Tender For Construction Of Esm Complex At Faridabad, faridabad-Haryana

Statutory Bodies & Commissions/Committees has published Tender For Construction Of Esm Complex At Faridabad. Submission Date for this Tender is 25-09-2024. Hosiery Tenders in faridabad Haryana. Bidders can get complete Tender details and download the document.




Tender Notice

45038423
Tender For Construction Of Esm Complex At Faridabad
Open Tender
Indian
Haryana
Faridabad
25-09-2024

Tender Documents

Tender Details

Tender For Construction Of Esm Complex At Faridabad; 1 SCHEDULE `A PART - I Building is not prepriced by MES and prepriced rates indicates0.00 under column 5 signifies this fact only. 2 Construction of Defence Institutional Complex (DIC)complete withpermanent specification as specified and as shown in drawings. 3 NOTE: Schedule ‘A’ Part IIto IX under Ser No 2.01 to 2.08 are Prepriced by MES. 4 Lump sum price worked out by the Contractor for “ SITE CLEARANCE, EXCAVATION AND EARTH WORK” as listed in Schedule ‘A’Part II 5 Lump sum price worked out by the Contractor for “INTERNAL ELECTRIFICATION” as listed in Schedule ‘A’Part III 6 Lump sum price worked out by the Contractor for “INTERNAL WATER SUPPLY as listed in Schedule ‘A’Part IV 7 Lump sum price worked out by the Contractor for SEWAGE DISPOSAL” as listed in Schedule ‘A’Part V 8 Lump sum price worked out by the Contractor for AREA DRAINAGE” as listed in Schedule ‘A’Part VI 9 Lump sum price worked out by the Contractor for “ROAD PATH AND CULVERT ” as listed in Schedule ‘A’Part- VII 10 Lump sum price worked out by the Contractor for“EXTERNAL WATER SUPPLY” as listed in Schedule ‘A’Part - VIII 11 Lump sum price worked out by the Contractor for“EXTERNAL ELECTRIFICATION, DG SET AND LIFT” as listed in Schedule ‘A’Part - IX 12 SCHEDULE `A PART - X MISC ITEMS (B/R & E/M)is not prepriced by MES and prepriced rates indicate 0.00 under column 5 signifie this fact only. 13 INTERNAL ELECTRIFICATION 14 S & F TV socket Jack RJ-45 type complete all as specified and as directed. 15 S & F indoor decorative LED battens integrated type 20 watts 4 feet white fixture and extruded aluminium body, suitable for LED tube 20 Watts, bi pin holder, connector block, incl LED rod 20 watts with all accessries internally wired and connected up with three core copper conductor complete all as specified and as directed. 16 S & F indoor decorative LED battens integrated type 10 watts 2 feet white fixture and extruded aluminium body, suitable for LED tube 10 Watts, bi pin holder, connector block, incl LED rod 10 watts with all accessries internally wired and connected up with three core copper conductor complete all as specified and as directed. 17 Supply and fixingElectric storage type water heater(Geyser) BEE 5 star rated, storage vertical type 25 litres capacity with stainless steel tank ,double insulated with outer cover of fiber glass (plastic ) rated at 240V single phase AC including necessary fitting and fixtureand 2 Nos of 450 mm stainless steel pipe for cold & hot water connection complete including fixing with clamps, brackets, screws etc. and also connecting up complete all as specified and as directed. 18 Supply and fixingceiling fan five star 1400 mm sweep, 230 volts (single phase) and provisioning of flexible copper cord three core PVC sheathed of size 23/0.0076 of required length from ceiling rose or connector to ceiling fan for giving connectioncomplete all as specified and as directed by the Engineer-in-Charge. 19 Supply and fixing Plastic body exhaust fanof size 300 mm sweep, 1400 RPM, 230 volts single phase AC supply with louvers complete with, bolt, nuts and washers, suitably embedded in the wall including making suitable opening and provisioning of flexible copper cord three core PVC sheathed of size 23/0.0076 for giving connectionfrom suitable electric point to exhaust fan complete all as specified and as directed by the Engineer-in-Charge. 20 Supply and fixing Metal body exhaust fanof size 450 mm sweep, 1400 RPM, 230 volts single phase AC supply with louvers complete with, bolt, nuts and washers, suitably embedded in the wall including making suitable opening and provisioning of flexible copper cord three core PVC sheathed of size 23/0.0076 for giving connectionfrom suitable electric point to exhaust fan complete all as specified and as directed by the Engineer-in-Charge. 21 S&F sheet metal enclosures Vertical type double door (VTPN) MCCB incomer, withacrilic door, cement spill protector for MCCB Triple pole and neutral, 4 ways, IP-43 protection, with 200 amps rated bus bar with four pole MCCB of 125 Amp breaking capacity 16 KA , 415 Volts complete all as specified and as directed 22 S&F MCB TPN63 Amps, C curve type 10 KA Breaking capacity 240 Volts complete all as specifird and as directed. 23 S&F MCB SP 6 to 32 Amps, C Curve type 10 KA breaking capacity 240 Volts complete all as specifird and as directed. 24 S&F MCB SPN 40 Amps, C Curve type 10 KA breaking capacity 240 Volts complete all as specified and directed. 25 EXTERNAL ELECTRIFICATION 26 Supply, Installation, testing and Commissioning of transformer step down outdoor type 11 KV, 433 volts three phase 50 Hz, 100KVA (Level-III) capacity core type double copper wound coil immeresed, naturally cooled oil natural air natural (ONAN) , with external cooling tubes / fins , delta connection on primary side (HV side) and star connected to secondary side (LV side) in accordance with vector group Dyn11 with neurtal brought out on secondary side (LV side) and having seven tap positions on HV side for voltage variation from +5% to -10% in steps of 2.5% for HV side to be changed by the mains of hand operated off load tap changing gear. Max losses at 75 °CTemp rise at 50% of load shall not exceeds 392 watts and at 100% load shall not exceed 1365 watts. 27 The max temperature rise should not increase 40°C in oil (measured by thermameter) and 45°C in HV/LV windings (measured by resistance method) after continous full load run on an ambient temperature of 40°C. The transformer shall be IS 1180 (Part-1 2014) and ammended upto date including initial filling of transformer oil confirming to IS- 335 and shall comprise of following : (a) Three nos porcelain bushing suitable for 11 KV on HV side complete with brass/copper rod , nuts/washers and cable box .(b) one cable box on LT side (Secondary side) consisting of four nos porcelain bushings with copper rods complete withnuts/washerswith cable glands suitable for taking out of LT 1100 Volts grade XLPE armoured cables including jointing materials complete. (c) Oil conservator with filler type drain valve and oil temerature gauge. (d) Dehydrating breather with first fill of dehydrating agent ( Silica Gel) . 28 (e) Expansion ventthermometer pocket on tank cover , oil level gauge , oil drain filter, filter valve, lifting lugs/jacks , oil filling hole with cap/plug with connection plate complete , air release valve plug and 04 nos plain solid caste stell deattachable rollers. (f) 01 No dial type thermometer vapour pressure type having range 0°C to 120°C . (g) Two earthing terminals on tank cover to facillitate fixing of 32/6 mm GI earth strips for body earthing.(h) Rating plate and terminal marking plate(j) Extra bushing for neutral in the LT cable box for providing independent set of earthing for Neutral.Note : Quoated rate shall be inclusive of providing T&P required for testing and commissioing of transformer 11/0.433KV ,100 KVA ratingto the propsed location by providing hydra and tractor trolley complete. 29 Supply , fabrication, Testing and Commissioning (including CPRI type test certified ), Outdoor type, floor mounted , cubicle type LT panel board suitable for 415 volts, 3 phase 4 wire 50 Hz AC supply system having busbar chamber with insulated for the Panel shall be dust and vermin proof IP-66 class protection and made of 3 mm, CRCA MS sheet,double door,front and Back opening with proper locking arrangement ,lifting lugs,rubber gasket on front and back to make it dust and vermin proof , and 50x50x6MM thick MS angle iron, frame work , copper busbar 300 Amps for 3 phase 4 wire system, powder coated finish over two coat of redoxide primer, including internal wiring with PVC insulated strandedFRLS, copper conductor cable , IS-694 marked , 1100 volts grade of appropriate size (but not less than 4.0 Sqmm ), PCC foundation for mounting of Panel and comprising of following: 30 INCOMING:-(i) MCCB 4-Pole200 Amp 415 volts AC, 25KA rupturing capacity adjustable thermal type -01 No (incoming)(ii) Analog type Voltmeter 0-500volts square 96mm flush pattern with rotary selector switch - 01 Set(iii) Analog type Amp meter square 96mm flush pattern having range 0-200 Amp with 3 way rotary selector switch and CTs of Suitable range - 01 No(iv) Indicating lamp, LED type (Red ,Yellow, Blue) - 01 No(v)Copper bus bar 300 Amp with insulator - 04 Nos(vi) Connection and internal wiring complete - 01 Job 31 OUTGOINGS:-(i) MCCB TPN 63 Amp 415 volts AC, 16KA rupturing capacity-03No (ii) MCB SPN 20 Amp 415 volts AC, 10KA rupturing capacity-01 No (iii) All incoming & out going feeders shall be connected by cable gland plates/glands (iv) The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint. 32 M&L for LT Pole box for security/Street light weather proof made out of PVC fire retardant non fusing sock and dust proof one piece molded SMC base and SMC cover with hinged door all mounting type comprising of aluminium 25Ampbus bar with MCB SP 10 amp of size 300x200x100mm, fixed on pole with MS clamps 20x3mm with necessary nuts, washers and incl applying two coats of synthetic enamel paint over red oxcide primer on steel surface/clamps and embrossing/painting of danger sign ofsize not less than 10cmsX7.5 cms with letter and conventional skill and bones in signal red colour on front face of kisko box complete all as directed. 33 Supply and fixing lightening arrester expulsion type complete with all fittings transmission class discharge capacity up to10 kilo ampere HT 11KV, 65KAstation class and shall comply with the requirements of routine test as a specified in the relevant IEC: 99-4 and IS- 3070 (Part-III) complete all as specified and directed by engineer in charge 34 EXTERNAL WATER SUPPLY 35 M&L construction of brick masonary valve pit/ chamber of size internal dimension of 900X900X1200 mm size (Type B:) in PCC block masonry built in CM(1,6) with MS cover 3 mm thick and angle iron frame 40 x 40 x 5 mm with locking arrangement including excavation and earth work in any type of soil, PCC (1:4:8) type D-2 for foundation, PCC bed/coping in cement concrete (1:2:4) type B1,plastering 15 mm thick in CM (1:4), painting with one coat of red oxide primer and 2 coats of bituminous black paint on all steel surface all as specified and directed by Engr-In-Charge. 36 AIR CONDITIONING AND REFRIGERATION 37 Supply and install wall mounted inverter type split unit indoor/outdoor complete of capacity 2 TR with cordless remote control unit with inbuilt air ionizer and plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2 complete all as specified and directed by engineer-in-charge. 38 DG SETS 39 Supplying, installing, commissioning and testing silent Diesel engine driven Ea Generating Set 415 volts 3 phase 4 wire 100 KVA/80KW capacity mounted Aesthetic weather proof as per CPCB (Central Pollution Control Board) - IV norms, as per latest IS norms & noise level shall not exceed 75 db at a distance of 2 metre conforming to Engine BS-5514, ISO 3046 and Alternator BS 5000, IS 4722, IS 13364 (Part 1&11) Genset ISO 8528 complete with relay panel and switch gear for automatic starting on main failure control panel having meter relay and comprising of the following:(A) Diesel Engine: Diesel Engine developing not less than 125 BHP at NTP, 1500 RPM turbocharged cooled engine inclusive of the following standard accessories 40 (a) Radiator cooling system(b) Spider coupling guard(c) Flywheel to suit flexible coupling/closed coupled(d) Fly wheel housing complete with starter gear ring and coupling (e) Fuel houses (f) Air cleaner(g) Fuel and lub oil filter(h) By pass filter(i) Coolant inhabitor(k) Fuel pump PTR type/in line monoblock fuel injection pump(1) Water pump(m) Lub oil pump(n) Electric starter 12 volts DC(0) Industrial silencer(p) Control push pull(q) Lub oil cooler 41 (B)Alternator: Alternator suitable for continuous operation generating 100 KVA/80 KW at 1500 rpm 415 volts at NTP 0.8 power factor 3 phase 50 Hz, self excited & regulated with ball/roller bearings conforming to IS-4722. (C)Fuel tank suitable capacity to run 24 hrs made out of 14 SWG MS sheet powder coated with inlet and outlet connection and fuel level indicator. (D) Base frame fabricated from MS channel of suitable size and machined to ensure perfect alignment.(E) One Nos battery of 12 volts each 100 AH lead acid type(F)Supply, installation, testing and commissioning of AMF (Automatic Main Failure) panel suitable for generating set for capacity 100 KVA grouted in the floor with PCC/RCC foundation factory made indoor cubical type front operatable fabricated from MS sheet (1.6 mm) of suitable size comprising power contractors ML-30 or equivalent capacity of 42 other bus chamber copper bus bar of current rating 400 Amps with high insulation & instantaneous tripping device suitable for complete panel over current 0.5 Amps, electronic letch circuit with tripping indication of each shape of fault and provisions of reset facilities complete protection of AMF panel, painted with powder coating of following features:- (a) 3 Phase MVR relay unit for main power contractor built with single phase protection both on LV/HV side, 3 phase low voltage cut off at 200 volts reverse phase protection, 3 phase high voltage cut off 460 volts unbalance voltage tripping, separate indication lights for each tripping and 3 phase mains on front panel having 2 NO/NC 6 Amps interlocking auxilary contacts - 01 No. (b) Description all as per Srl item No (F) (a) herein before but of 3 phase AVR relay unit for generator supply contactor with same specifications as above- 01 No. 43 (c)Self sequential starting relay unit 24 volt DC with dual interlocking timer for self on, self off (3sec-15 sec) adj independently with another timer for set fails to start alarm with self power contactor 24 volts DC 25 Amps-01 No. (d) Electronic timer 220 volts 50 Hz ON relay (10 sec-40 sec) Adj to restore commercial supply from main power contactor with 1 No/NC auxiliary contact 6 Amps, 18 volts, 500 ohms-01 No.(e) Description all as per Serial item No (H) (d) above but OFF relay for fuel cut off operation for solenoid valve with fuel power contactor 24 volt DC, 25 Amps-01 No. (f) Battery charging unit 24 volt 10 Amps consisting of step down transformer with primary tap selector, bridge rectifier alongwith shunt capacitor having digital battery voltmeter (0-30) volts of 3.5 digit LED/LCD/FND display panel mounting type also featuring trickle/boost & off facility - 01 set. 44 (g) Digital 4 digit frequency meter (30-70) Hz having LED/LCD/FND display panel mounting mains operated - 01 No.(h)MCCB, 4 pole, 200 A, 35 KA with adjustable over load & adjustable short circuit.Note :-The quoted rates includes the DG Set foundatiion as per manufacturers instruction and as specified by Engineer-in-Charge. 45 LIFT 46 Design ,Supply installation, erection and commissioning and testing of passenger Lift of capacity 8 person (544 kg) with microprocessor controller variable voltage variable frequency (VVVF) best having selective collection control center opening steel power operated car and landing door system speed 1.5 m per second serving ground floor to upper floor G+2(upto 2 floor)infrared screen sensor to since the complete lift opening overload warning indicator intercom system with signal automatic push operation with /without attendant having suitable car/cage size to house the door and stainless steel handle on all sides of cage floor announciator with music arrival Chrome full length car operating panel emergency lift car cage made out of min 18 SWG stainless steel (moon Rock finish) as well as cage roof covered with stainless steel sheet of suitable size cage floor made iron stainless steel chequered plate 5 mm thick travel guide rails for operation on 415volts 3 phase 50 Hz AC including the following:- 47 (a) Cage with a four number LED 9 watt and cabin fan one number 300 mm sweep with grill (b)Machine guide rail in T section with longue & groove arrangementfor smooth operation of car and counter weight.© Landing - 03 Nos (G+2) (d) Rated speed -1.5 m per second (e) Rated load 8 passenger -544 kgs(f)Nos of opening & Stops - 3/3 (Three stops and three openings)(g) Electric motor AC 415 volts, 3 phase 50 c/ss of suitable capacity electric cableing (FRLS) including all necessary PVC conduits of suitable size control panel and MCB(h) Type of operations- Single automation post button(j) Type ofcontrol -microprocessor variable voltage and variable frequency (VVVF) 48 (k) Type of signal system- Hall button with digital hall position indicator digital car postition indicator in car. All fixtures in stainless steel face plate (2mm Thick) (i)Provision of travelling cables with copper conductor junction boxes wiring having copper conductor cables with provision of suitable size of GI/PVC through and others accessories complete (m)Automatic rescue device battery operated to bring the car cage to the nearest floor and auto opening for evacuation of passenger in the event of power failure and also to operate alarm and emergency light having power backup for a period of minimum 1 hr (60 minutes) with battery charge of adequate capacity for battery charging within 2 hours after it use.(n) Earthing connection of the machine drive motor and control panel shall be done to the earth during earthing and Earth strip shall be measured and paid for seperately. 49 (o)RCC/ PCC foundation and all specified and directed complete with suitable size MS ISMB bolts grouting plates etc.(p)Provision of hoist way and governors rope with governor(q)Provision of buffer springs as per manufacturers design(r)Car cabin will have VVVF drive with power doors(s)Provision of dust proof inspection box on Car top(t)Provision of inverter of adequate capacity to operate the car cabin fan car light emergency light and alarm bell, intercom with battery backup for minimum 1 hour in event of electric breakdown and with battery charging system complete all specified and directed by engineer-in-charge.(u)Provision of any other components not considered above and required at the time of execution for smooth functioning of lift as a whole.(v)Provision of suitable cap CVT for the new microprocessor controller to safe guard the electronic circuit and enable smooth functioning of lift in case of voltage fluctuation in the system 50 (w)Provision of safety guarding eqpt such as two knobs with switches controller guarding pit pulley guarding ,pit ladder fascia plate 2 cover free space between car cabin and host way and rain switches etc.(x)Provision of Fireman switch complete at ground floor fitted inbox having stainless steel face plate 2 mm thick and covered with glass cover.Safety Measures:(i) Overload relays(ii)Contactor and fuses(iii)Electrical terminals high quality(iv)Limit switch with accessories on each door /cage(v)Gravity counter vate limit switches for top most position.(vi)Break motor of suitable size with men release management.(vii)Phase sequence character and single phase preventer 51 Note :(i)Press and speak system to be connected with existing machine room independently.(ii)Existing intercom in the cabin machine room shall be connected with existing communication network as desired(iii)DOs and Dont steel plate have to be installed inside the car cabin. 52 Supply ,Installingand Testing &Commissioning Servo controlled voltage stablizer 3 phase 50 Hz, 30 KVA rating static IGBT-Type voltage regulation Air cooled ,Indoor Type with Input Correction voltage352 to 477V out of voltage 415V +/- 1% rate/speed of correction 3000V/Sec complete with 20m seconds i.e within one wave form.The static stabilizer to give a reak time correction and other fittings/accessores complete as per standard manufacturing . 53 Supply installed test and commissioning of LT panel indoor type cubical, type factory fabricated out of MS of 2 mm thick dust vermin proof, weather proof, IP- 54 grade of protection fabricated on 50x50x5 mm thick MS angle iron frame both side opening and locking arrangement including providing bus bar chamber of capacity 100 ampere rating for 415 V 50Hz system including interconnection with solid conductor/strips/wires/cable with hot shrinkcolour coded sleeves with RYB colour and suitable adopter boxes with spreader links for connecting cables with switch terminals (Where necessary) complete with following:- (Lift Panel Type III ) (ground)INCOMING & OUTGOING(a) MCCB 63 Amps 4 Pole 16KA(b) Voltmeter 0-500 volt(c) Amperemeter 0-200 Amp(d) LED Indicator Set 54 AREA DRAINAGE 55 S&F SRFC drain covers with perforated holes factory made of size 500mm x 1000mm and minimum 75 mm thickness, set in cement mortar 1:4 complete all as specified and as directed.

Key Value

Document Fees
INR 3000 /-
EMD
INR 525000.0 /-
Tender Value
INR 4.50 Crore /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Notice 0 KB
Click here to download tender document Tender Document 0 KB
Click here to download tender document Tender Document 0 KB
Click here to download tender document Tender Document 0 KB
Click here to download tender document Tender Document 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail