| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 26-09-2024 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 01-10-2024 |
| 2 | 19-09-2024 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 26-09-2024 |
| Sl. No. | Item Description |
| 1 | Excavation in trenches in soft / loose soil nexc 1.5 mtr wide and not exc 1.5 mtr in depth etc complete and getting out in soft soil inciuding trimming sides and bottom of trenches complete all as specified and directed by Engr-in- charge. |
| 2 | Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft soil, complete all as specified and directed by Engr-in-charge. |
| 3 | Returning filling in trenches including watering and well ramming in layer not exc 25 cm thick in soft/ loose soil complete all as specified and directed by Engr-in- charge. |
| 4 | Removing excavated surplus soil to a distance not exc 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed by Engr-in-charge. |
| 5 | M&L for manual Boring of holes under road, pavement, Hard standing by trenchless technique, for passing GI/CI/DI pipe upto 100mm dia, complete all as specified and directed by Engr-in-charge. |
| 6 | Taking up U/S CI/DI water main(incl all fitting) with spigot & socket /MS pipe or any other type of pipe or lead joint incl burning out joint & recovering lead from pipe upto 150mm bore for laying /rerouting of serviceable pipe after cleaning complete all as specified and directed by Engr-in-charge. |
| 7 | All as per Item No 6 Above but 200 mm dia, complete all as specified and directed by Engr-in-charge. |
| 8 | S&F ofDI pipes of size 100mm bore with spigot and socket end centrifugally cast class \"K- 7\" , in any length laid in trenches/on surface/ over masonary pillar and connection to old or new position, complete all as specified and directed by Engr-in-charge.Note: DI fitting /lead joint / Tyton joint will be measured and paid seperately all the dismanted / demolished /taking down material shall be reused or removed from site. |
| 9 | All as per Item No 08 Above but 150 mm dia, complete all as specified and directed by Engr-in-charge. |
| 10 | All as per Item No 08 Above but 200 mm dia, complete all as specified and directed by Engr-in-charge. |
| 11 | S&F of Cast iron pipes of size 80mm bore with spigot and socket ends centrifugally cast. Class LA, in any length, laid in trenches/floor, complete all as specified and directed by Engr-in-charge. Note: DI fitting /lead joint / Tyton joint will be measured and paid seperately. All the dismanted / demolished /taking down material shall be reused or removed from site. |
| 12 | All as per Item No 11 Above but 100 mm dia, complete all as specified and directed by Engr-in-charge. |
| 13 | All as per Item No 11 Above but 150 mm dia, complete all as specified and directed by Engr-in-charge. |
| 14 | All as per Item No 11 Above but 200 mm dia, complete all as specified and directed by Engr-in-charge. |
| 15 | S&Fin replacement of DI/CI bend any type radius and angle tapers any type straght bend increacing decreacing or double socket etc) tee pipe single branch y junction double branch cross(all socket and spiogat collars caps and plug for the pipe socket & spiogat of the following size upto 150 mm dia complete all as specified and directed by Engr-in-charge.Note: Lead /gasket for fitting shall be measured and paid separately. |
| 16 | M&L for cutting of existing CI/DI pipe line in position for rectifying leakage and reducing to required length, in position, for insertion of collars or other fittings including necessory exvation and earthwork, dewatering etc,if any involed for 80mm bore of pipes complete all as specified and directed by Engr-in-charge.Note for item no: 10, 11, 12 & 13:S&F of insertion of fittings /pipes pieces etc shall be measured & paid for separately. |
| 17 | All as per item No: 16 above but of 100m bore pipe, complete all as specified and directed by Engr-in-charge. |
| 18 | All as per item No: 16 above but of 150m bore pipe, complete all as specified and directed by Engr-in-charge. |
| 19 | All as per item No: 16 above but of 200m bore pipe, complete all as specified and directed by Engr-in-charge. |
| 20 | M&L in replacement of ruber gas ket joint/ tyton jointfor CI/DI pipe of size100 mm bore, complete all as specified and directed by Engr-in-charge. |
| 21 | M&L in replacement of ruber gas ket joint/ tyton jointfor CI/DI pipe upto size 150 mm bore, complete all as specified and directed by Engr-in-charge. |
| 22 | S&F in replacement of pig lead slab of superior quality for CI/ MS pipe lineall as specified and directed by Engr-in-charge. |
| 23 | S&F in replacement of Spun yarn for CI/ MS pipe line all as specified and directed by Engr-in-charge. |
| 24 | S&F of DI/CI MJ collar suitable for 80mm Dia, ISI marked including nut, bolt, washer and gasket of suitable & size of any quantity as per site requirment, for leakage repair in CI/DI pipe, complete all as specified and directed by Engr-in-charge.Note: Excavation & other CI/DI fittings will be measured & paid Saperately in respective item. |
| 25 | All as above item No: 24 but of size 100mm dia |
| 26 | All as above item No: 24 but of size 150mm dia |
| 27 | All as above item No: 24 but of size 200mm dia |
| 28 | S&F of CI/DI leakage clampssuitable for 80/100mm Dia, ISI marked including nut, bolt, washer and gasket of suitable & size of any quantity as per site requirment, for leakage repair in CI/DI pipe, complete all as specified and directed by Engr-in-charge.Note: Excavation& other CI/DI fittings will be measured & paid Saperately in respective item. |
| 29 | All as above item No:28 but of size 150mm dia |
| 30 | All as above item No:28 but of size 200mm dia |
| 31 | M&L for welding of MS flange on MS pipe upto 200mm dia including making grooves/bore for nut bolts in flangecomplete all as specified and directed by Engr-in-charge. |
| 32 | Taking out existing U/S NRV of size 50-200 mm borecomplete all as specified and directed by Engr-in-charge. |
| 33 | Suply and fixing of cast iron NRV flanged end of size 200 mm dia with all fitting and accessories,complete all as specified and directed by Engr-in-charge. |
| 34 | All as per item no: 33 above but 150 mm dia, complete all as specified and directed by Engr-in-charge. |
| 35 | All as per item no: 33 above but 100 mm dia, complete all as specified and directed by Engr-in-charge. |
| 36 | All as per item no: 33 above but 80 mm dia, complete all as specified and directed by Engr-in-charge. |
| 37 | Suply and fixing in replacement of Brass/gun metal NRV threaded end type of size 50 mm dia with all fitting and accessories,complete all as specified and directed by Engr-in-charge. |
| 38 | Taking down carefully cast iron sluice valve of size 200 mm bore from CI water mains, dismantling parts and reassembling, replacement of ss spindle for sluice valve, class PN 1.6, and repacking stuffing box of sluice valve spindle, refacing, regrinding and refixing in original position including provision of nuts, bolts, washers, rubbers gaskets etc complete all as specified and directed by Engr-in-charge. |
| 39 | All as above item No: 38, but for 150mm dia sluice valve, complete all as specified and directed by Engr-in-charge. |
| 40 | All as above item No: 38, but for 100mm dia sluice valve, complete all as specified and directed by Engr-in-charge. |
| 41 | All as above item No: 38, but for 80mm dia sluice valve, complete all as specified and directed by Engr-in-charge. |
| 42 | Taking out existing U/S CI sluice valve of any size any pattern up to 200 mm borecomplete all as directed. |
| 43 | S&F of Cast iron sluice valve of size 80 mm dia Stainless steel stemPN- 1.6 ( Flanged) conforming to IS 14846 hand wheel operated,complete all as specified and directed by Engr-in-charge. |
| 44 | All as per Item No 43 Above but 100 mm dia,complete all as specified and directed by Engr-in-charge. |
| 45 | All as per Item No 43 Above but 150 mm dia, complete all as specified and directed by Engr-in-charge. |
| 46 | All as per Item No 43 Above but 200 mm dia, complete all as specified and directed by Engr-in-charge. |
| 47 | Supply and laying in replacement of galvanised steel water tubing medium grade in trenches / wall /floor with all fittings , connections as required at site of size 15 mm bore, complete all as specified and directed by Engr-in-charge. |
| 48 | All as per Item No 47 Above butBore of pipe 20 mm, complete all as specified and directed by Engr-in-charge. |
| 49 | All as per Item No 47 Above butBore of pipe 25 mm, complete all as specified and directed by Engr-in-charge. |
| 50 | All as per Item No 47 Above but Bore of pipe 50mm, complete all as specified and directed by Engr-in-charge. |
| 51 | All as per Item No 47 Above but Bore of pipe 80mm, complete all as specified and directed by Engr-in-charge. |
| 52 | All as per Item No 47 Above but Bore of pipe 100mm, complete all as specified and directed by Engr-in-charge. |
| 53 | S&F in replacement of Stop valve gun metal valve with iron handle screwed both ends for iron pipe and fixed of size 15 mm bore, complete all as specified and directed by Engr-in-charge. |
| 54 | All as per Item No 53 Above butBore of pipe 20mm, complete all as specified and directed by Engr-in-charge. |
| 55 | All as per Item No 53 Above butBore of pipe 25mm, complete all as specified and directed by Engr-in-charge. |
| 56 | All as per Item No 53 Above but Bore of pipe 50mm, complete all as specified and directed by Engr-in-charge. |
| 57 | S&F in replacement of GI socket of 15 mm ISI marked complete all as specified and directed by Engr-in-charge. |
| 58 | All as per Item No 57 Above butBore of pipe 20mm, complete all as specified and directed by Engr-in-charge. |
| 59 | All as per Item No 57 Above butBore of pipe 25mm, complete all as specified and directed by Engr-in-charge. |
| 60 | All as per Item No 57 Above but Bore of pipe 50mm, complete all as specified and directed by Engr-in-charge. |
| 61 | S&F in replacement of GI union of 15 mm ISI marked complete all as specified and directed by Engr-in-charge. |
| 62 | All as per Item No 61 Above butBore of pipe 20mm, complete all as specified and directed by Engr-in-charge. |
| 63 | All as per Item No 61 Above butBore of pipe 25mm, complete all as specified and directed by Engr-in-charge. |
| 64 | All as per Item No 61 Above but Bore of pipe 40 mm, complete all as specified and directed by Engr-in-charge. |
| 65 | All as per Item No 61 Above but Bore of pipe 50 mm, complete all as specified and directed by Engr-in-charge. |
| 66 | S&F in replacement of GI nipple of 15 mm, 6 \" longISI marked complete all as specified and directed by Engr-in-charge. |
| 67 | All as per Item No 66 Above butBore of pipe 20mm, complete all as specified and directed by Engr-in-charge. |
| 68 | All as per Item No 66 Above butBore of pipe 25mm, complete all as specified and directed by Engr-in-charge. |
| 69 | All as per Item No 66 Above but Bore of pipe 40 mm, complete all as specified and directed by Engr-in-charge. |
| 70 | All as per Item No 66 Above but Bore of pipe 50 mm, complete all as specified and directed by Engr-in-charge. |
| 71 | S&F in replacement of GI elbow of 15 mm medium grade ISI marked complete all as specified and directed by Engr-in-charge. Make- Unik/Tata/Jindal |
| 72 | All as per Item No 71 Above butBore of pipe 20mm, complete all as specified and directed by Engr-in-charge. |
| 73 | All as per Item No 71 Above butBore of pipe 25mm, complete all as specified and directed by Engr-in-charge. |
| 74 | All as per Item No 71 Above but Bore of pipe 40 mm, complete all as specified and directed by Engr-in-charge. |
| 75 | All as per Item No 71 Above but Bore of pipe 50 mm, complete all as specified and directed by Engr-in-charge. |
| 76 | S&F in replacement of GI Reducer of 20x15 mm medium grade ISI marked complete all as specified and directed by Engr-in-charge. |
| 77 | All as per Item No 76 Above but Bore of pipe 25x20 mm complete all as specified and directed by Engr-in-charge. |
| 78 | All as per Item No 76 Above but Bore of pipe 40x25 mm complete all as specified and directed by Engr-in-charge. |
| 79 | All as per Item No 76 Above but Bore of pipe 50x40 mm complete all as specified and directed by Engr-in-charge. |
| 80 | All as per Item No 76 Above but Bore of pipe 50x25 mm complete all as specified and directed by Engr-in-charge. |
| 81 | S&F in replacement of GI Tee of 15mm medium grade ISI marked complete all as specified and directed by Engr-in-charge. |
| 82 | All as per Item No 81 Above butBore of pipe 20mm, complete all as specified and directed by Engr-in-charge. |
| 83 | All as per Item No 81 Above butBore of pipe 25mm, complete all as specified and directed by Engr-in-charge. |
| 84 | All as per Item No 81 Above but Bore of pipe 40 mm, complete all as specified and directed by Engr-in-charge. |
| 85 | All as per Item No 81 Above but Bore of pipe 50 mm, complete all as specified and directed by Engr-in-charge. |
| 86 | S&F Dead plug of size 15mm to 50mm dia complete all as specified and directed by Engr-in-charge. |
| 87 | Dismounting of monoblock 5 HP pumpand motor from foundation including disconnecting all electric connection suction / delivery line connection andtransporation to pumping set civil work shop and return to store after repair including Re- assembing of motor and testing and commissioning complete all as specified and directed by Engr-in-charge. |
| 88 | Taking out the pump from the motor and rewinding of5 HP motor with super enamelled copper wiresame gauge & size includinng all insulating material i.e. sleeves stick and insulation sheet and replacement of the following parts complete all as specified and directed by Engr-in-charge:- (a) Replacement of driving and non driving end ball bearing-02 Nos. (b) Balanceing of rotor including straightening of strip -02 Job.(c) Replacement of bearing bush upper and lower-02 Nos.(d) Repair to pump & its seals etc-1 Nos |
| 89 | Taking out existing U/S valve chamber incl brick work & PCC work complete all as specified and directed by Engr-in-charge. |
| 90 | M&L for construction of valve chambers with MS cover 3 mm thick of valve pit of size 900x900x900 MM( internal dimensions) including necessary excavation, earth work 150 mm thickPCC 1:4:8 Type D2 as in foundation, PCC 1:2:4 Type B1 in coping plastering 15 mm thick in cm 1:4,and angle iron frame50x50x06 mm and locking arrangement including painting with coat of synthetic enameled paint over a coat of redoxide primer after preparation of surface complete all as specified and directed by Engr-in-charge. |
| 91 | Removing of u\s leakage tank from roof /Surface and disconnecting all fitting and fixture. Up to 1000 ltr from 5000 ltr. complete all as specified and directed by Engr-in-charge. |
| 92 | Supply and fixing of rotational moulded polyethy lene water storage tank (cylindrical vertical with closed top ) hoisted and fixed in position all as specified in SSR part I. of size 1000 Ltrs complete all as specified and directed by Engr-in-charge. |
| 93 | All as per item No 92 but 500 ltr,complete all as specified and directed by Engr-in-charge. |
| 94 | Removing of the existing u/s float valve from the tank of any capacity, complete all as specified and directed by Engr-in-charge. |
| 95 | Supply and fixing of PVC float valves ( Ball valve) high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed, of size 15 mm dia.including all fittings, complete all as specified and directed by Engr-in-charge. Make- prayag or equivalent make |
| 96 | All as per item No 95 but 20 mm dia, complete all as specified and directed by Engr-in-charge. |
| 97 | All as per item No 95 but 25 mm dia, complete all as specified and directed by Engr-in-charge. |
| 98 | M&Lfor minor reparing / rectified and attending the complaint of pipe line leakage and reparing of any size by highly skilled trades man and making functional including all GI fittings like elbow, socket, Tee, Nipple, bend, union etc and making new threads as required at site including excavation,return refilling and removing soil & earth work etc. complete all as specified and directed by Engr-in-charge. |
| 99 | S&F in replacementof PVC insulatedcopper conductor cable flat/round 3 core 4 sqmm 1100 volt, complete all as specified and directed by Engr-in-charge. |
| 100 | S&F in replacement PVC insulatedcopper conductor cable flat/round 3 core 6 sqmm 1100 volt, complete all as specified and directed by Engr-in-charge. |
| 101 | S&F copper lugs size varying from 6 sq mm to 35 sqmm for jointing cable, complete all as specified and directed by Engr-in-charge. |
| 102 | S&F Aluminium lugs size varying from 25 sq mm to 95 sqmm for jointing cable, complete all as specified and directed by Engr-in-charge. |
| 103 | Supply only Chlorine Testing kit with coloured ample complete with all testing fitments and OT solution in Rexene finish box complete all as specified and directed by Engr-in-charge. |
| 104 | M&L for Removal of the existing paint from the pumping set & LT panel of any sizeby the hand scrapping and painting gray colour for the motor, Blue colour for pumps and black colour for the pump base& grey for LT panel with two coat of synthetic enamel paint and rewriting the SM NO. complete all as specified and directed by Engr-in-charge. |
| 105 | M&L for Removal of the existing paint from the suction and discharge pipe line upto 200mm dia by the hand scrapping and painting black colour for the suction line and discharge line with two coat of synthetic enamel paint, all as specified and directed by Engr-in- charge. |
| 106 | S&F in replacement Nut, bolt, washer of different size ISI marked, complete all as specified and directed by Engr-in-charge. |
| 107 | S&F in replacement lather gasket ISI marked, complete all as specified and directed by Engr-in-charge. |
| 108 | Supply in repair of grease for pump servicing and filling of gland dori in pumpISI marked,complete all as specified and directed by Engr-in-charge. |
| 109 | Testing of Raw Water/Treated water for bacteriological analysis, Chemical analysis & dissolved salts i.e. manganese, arsenic, nitrates, Fluoride etc, parameters confirming as per IS:10500-2012from any Govt. Approved/recognized Lab as approved by the GE complete all as specified and directed by Engr-in-charge.Note:- 1) Contractor has to collect samples from various pump houses & borewells in Vayusenabad on alternately basis from different sources as directed by Engr-in-charge.2) Contractor will be responsible to carry out the sample & submitreport timely. |
| 110 | M&L in replacement for panel inbuilt change over switch 160A, 4 pole, open execution, Phase Barriers & Handle with door interlock kit is integral part of the Changeover Switch, complete all as specified and directed by Engr-in-charge. |
| 111 | M&L in replacement for panel inbuilt change over switch 100A, 4 pole, open execution, Phase Barriers & Handle with door interlock kit is integral part of the Changeover Switch, complete all as specified and directed by Engr-in-charge. |
| 112 | M&L in replacement for MCCB 3 pole 160 amps, thermal adjustable magnetic type, 36 KA complete all as specified and directed by Engr-in-charge. |
| 113 | M&L in replacement for MCCB 4 pole 160 amps, thermal adjustable magnetic type, 25 KA complete all as specified and directed by Engr-in-charge. |
| 114 | M&L in replacement for MCCB 3 pole 100 amps,thermal adjustable magnetic type, 35 KA complete all as specified and directed by Engr-in-charge. |
| 115 | M&L in replacement for MCCB 4 pole 100 amps,thermal adjustable magnetic type, 35 KA complete all as specified and directed by Engr-in-charge. |
| 116 | M&L in replacement for MCCB 3 pole 63 amps,thermal adjustable magnetic type, 35 KA complete all as specified and directed by Engr-in-charge. |
| 117 | M&L in replacement for MCCB 4 pole 250 amps,thermal adjustable magnetic type, 50 KA complete all as specified and directed by Engr-in-charge. |
| 118 | M&Lin replacement of ampere meter digital type, 415V suitable for existing panel CT operated of range 0-100 as required complete all as specified and directed by Engr-in-charge. |
| 119 | M&Lin replacement of ampere meter digital type, 230V suitable for existing panel CT operated of range 0-100, complete all as specified and directed by Engr-in-charge. |
| 120 | M&Lin replacement of voltmeter digital type, 415V suitable for existing panel CT operated of range 0-500, complete all as specified and directed by Engr-in-charge. |
| 121 | M&Lin replacement of LED indicator lamp, complete all as specified and directed by Engr-in-charge. |
| 122 | M&Lin replacement of panel mounted ON/OFF push button with contact block, complete all as specified and directed by Engr-in-charge. |
| 123 | M&L in replacement of CT50/5 complete all as specified and directed by Engr-in-charge. |
| 124 | S&F in replacement of LT panel connetor suitable for stater & MCCB connection made of heavy duty plastic with ss nut & bolt suitable for upto 50Amp, 215volts as per site requirement complete all as specified and directed by Engr-in-charge. |
| 125 | Supply only Calcium based granule Chlorine (calcium hypochlorite) having chlorine content upto 68% disinfect for water treatment complete all as specified and directed by Engr-in-charge. |
| 126 | Taking down carefully copper/aluminium point wiring (light, Fan, Socket or power) fitting such as switches, ceiling roses, pendents, regulators, sockets etc complete removing material to store for keeping in safe custody and making good disturbed surfaces of walls, floors etc complete all as specified and directed by Engr-in-charge. |
| 127 | Material & Labour for concealed point wiring with single core PVC insulated and unsheathed 1100 volts grade cable with multistranded copper conductor of size 1.5 Sqmm nominal area drawn through & including non metallic rigid PVC conduit (circular/flat pvc conduit), medium duty not less than 20 mm dia concealed in wall/fixed on wall/ceiling with GI saddles , GI screws , rawl plugs with all fittings including tees , junction boxes including fixing GI gang box of any module not less than 3.15mm thickness flushed in wall with hylem cover sheet of suitable size for mounting switches , sockets & regulators & drawing through continuous earth wire of PVC insulated unsheathed 1100 volts grade cable with copper conductor solid conductor of size 1.5 sqmmcomplete all as specified and directed by Engr-in-charge.Note: Cost for cutting chases in any type of wall/ceiling and supply & flushing conduit pipe, junction box, tee, PVC flexible pipe and GI gang box ( any qty, Nos & module) and making good to match the existing surface shall be deemed to be included in the quoted rate. |
| 128 | For one light point controlled by one single pole switch & socket. |
| 129 | For one fan point controlled by one single pole switch. |
| 130 | For one 3 pin sockets outlet 5 Amps on the same board with other switches with cable of size 1.5 sqmm |
| 131 | For 3 pin socket outlet 5 Amps independent with cable 1.5 Sqmm size |
| 132 | For one 3 pin sockets outlet 15 Amps idependent with cables 2.5sqmm size |
| 133 | Supply and Fixing ofmodular switches 1 way, 6 Amp 1 module complete all as specified & directed by Engineer - In-Charge. |
| 134 | Supply and Fixing of modular Socket, 6A - 2/3 pin combined 2 module, complete all as specified and directed by Engr-in-charge. |
| 135 | Supply and Fixing ofmodular switches 1 way, 16 Amp 1 module complete all as specified and directed by Engr-in-charge. |
| 136 | Supply and Fixing ofmodular Socket 6A/16A - 2/3 pin combined 2 module, complete all as specified and directed by Engr-in-charge. |
| 137 | S&F ofstepped type electronic fan regulator flush type 1 module, complete all as specified and directed by Engr-in-charge. |
| 138 | Supply & Fixing ofCeiling Rose, 3 phase polycarbonate isolated body including hylem/plastic round shape junction box cover & brass screw nuts, complete all as specified and directed by Engr-in-charge. |
| 139 | Supply and fix in replacement of factory made epoxy polyster powder coated distribution board SP&N 8 way fabricated from minimum 1.6 mm thick CRCA sheet with double door (IP-43 protection) fixed flush to wall and standard DIN rail, earth bar and cable ties for cable management, suitable for one incomingand 6 outgoings complete all as specified and confirming to IS: 8623 complete all as specified and directed by Engr-in-charge.Note: Cutting on wall and taking out old one and then flushing new DB and making all the connection as before and any accessories required to fix the DB including making good the disturbed surface is deemed to be included in quoted rate. |
| 140 | S&F in replacement of SPN MCB,32Amp , B Curve, 10 KA , complete all as specified and directed by Engr-in-charge. |
| 141 | S&F in replacement of SP MCB,6-32Amp , B Curve, 10 KA , complete all as specified and directed by Engr-in-charge. |
| 142 | S&F in replacement of TP MCB,63Amp , C Curve, 10 KA , complete all as specified and directed by Engr-in-charge. |
| 143 | S&F in replacement of Wiring for circuit/submain wiring alongwith earth wire in PVC conduit pipe with wire of2x4.0 sq. mm + 1x2.5 sq. mm earth wire of FR is PVC insulated copper conductor, single core cable in surface/recessed as required, complete all as specified and directed by Engr-in-charge. |
| 144 | M&L for cutting of grass, trimming of trees, removing stone, glass, metals etc by deploying sufficient no of labour as or when required and removing & disposing dry leafs, shurbs, branches etc. away from pumphouse, complete all as specified and directed by Engr-in-charge.Note: contrctor has to provide cutting tools, shovel, trowel, axe, gloves etc |
| 145 | S&F in replacement of fountain water submerged fountain light of 18/20watt, of IP66 protection, in SS casing, remote controlled, RGB colour changing/RGB controller, complete all as specified and directed by Engr-in-charge. |
| 146 | S&F in replacement of SMPS enclosed in sheet metal box with fuse of suitable capacity and of suitable rating as per site forfountainlight of 18/20watt, complete all as specified and directed by Engr-in-charge. |
| 147 | S&F in replacement of Fountain nozzels (SS/heavy duty plastic)as per site requirement, including repairing/replacement of PVC pipe upto 63mm dia, solvent, insulation tape etc. per fountain, complete all as specified and directed by Engr-in-charge. |
| 148 | S&F in replacement of Submersible cable 2 core 1.5sqmm for fountains, complete all as specified and directed by Engr-in-charge. |
| 149 | S&F in replacement sheet metal enclosed Three phase Direct on line starter of capacity 5 HP overload relay range 9-14 Amp complete all as specified and directed by Engr-in-charge. |
| 150 | Supply and fix in repair of rubber coupling suitable for 20/40 HP pump set as per existing pattern complete all as specified and directed by Engr-in-Charge. |
| 151 | S&F in repair of MS/GI Flange of size 50 to 200 mm and fixing of new one MS/GI Flange at same location where MS/GI Flange is taken out including nuts bolts etc all as specified and directed. |
| 152 | Supply and fixing in repair of pre-fabricated MSstructural steel (IS marked) work consisting of channels / angles /flats/ round bars/MS pipe &other sections etc of various sizes and shape, cut / weld / drilled holes etc hot / cold in position for cross arms with FI clamps (full, half D and earth clamp etc) incl necessary MS bolts, nuts etc and painting for hanging strcture for repair bay all as directed by Engr in Charge. |
| 153 | M&L in Repair of RustedCI Tail Piece of size 80mm to 200 mm at same location where CI Tail Pieceis taken outcomplete all as specified and directed by Engr-in-charge. |
| 154 | M&L for demolition of cement concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) for HDPE tank foundations, complete all as specified and directed by Engr-in-charge. |
| 155 | M&L for hard core of broken stone or boulders of gauge n.exc. 63mm deposited spread and levelled in layers n.exc. 15 cm thick watered and rolled/ rammed to a true surface complete all as specified and directed by Engr-in-charge. |
| 156 | M&L for Cement concrete in foundations, filling and mass concrete of Type C2 (1:3:6), (40 mm graded aggregate) for 5000Ltrs HDPE tank foundation, motor foundation etc. complete all as specified and directed by Engr-in-charge. |
| 157 | M&L for servicing of Solar water heater upto 500LPD (both vaccum tube type & flat plate collector) at various locations at Tech area & VSB area along with descaling the whole system by revolving liquid descaling agent in the copper tubes of solar water heater upto the satisfaction of JE E/M or not less than one Hour by deploying pressure pump & other equipment including plumbling work & removing minor leakage, unbalanced system defect etc, complete all as specified and directed by Engr-in-charge. |
| 158 | S&F in replacement of solar water heater collector tank ofcapacity 500LPD (heat exchanger type)inner tank made of SS, insulated with polyurethane & glass wool, anti corrosion body alongwith provision for mounting thermostat and heating element upto 3 KW all asper site to get incorporated in existing sytem, complete all as specified and directed by Engr-in-charge. |
| 159 | S&F in replacement of flat panel collector of size 2.17 sqm, working pressure 5Kg/sqcm, collector frame made of extruded aluminium 1.4mm thick, EPDM Utype gasket for lass (Beeding & sealing gasket made of EPDM rubber with brass adopter union type duly approved BIS, with absorber plate made of copper fins ultrasonically welded with copper tube, high efficicient absorption rate of 95% with black powder coating for frame & for glazingwater proof construction, case insulation made of PU which toughens the case and prevent heat loss, colleter made of polypropylene to prevent corrosion of size1992mmx1090mmx94mm having of copper tubingsuitable for solar plant of capacity 500 LPD complete all as specified and directed by Engr-in-charge. |
| 160 | S&F in replacement of thermostat suitable for 500LPD solar water heater model as per site requirement, complete all as specified and directed by Engr-in-charge. |
| 161 | S&F in replacement of Evacuted vaccum tube of 58mm dia, 100mm long, suitable for Evacuted vaccum tube solar collectorwater heater, complete all as specified and directed by Engr-in-charge. |
| 162 | S&F in replacement of 58mm dia silicon gasket as per site requirement complete all as specified and directed by Engr-in-charge. |
| 163 | S&Fin replacement of auto make up tank of 5ltrs capacity made of SS tank suitable to mount on existing sytem, complete all as specified and directed by Engr-in-charge. |
| 164 | S&F in replacement of flexible multilayer composite pipe (Model 2025)for hot/cold water connection in solar collector plate of size 25mm dia, 200mm long including necessary SS clamps, complete all as specified and directed by Engr-in-charge. |
| 165 | S&F in replacement of flexible multilayer composite connector (Model 2025)for hot/cold water connection in solar collector plate of size 25mmx20mm dia including necessary SS clamps, complete all as specified and directed by Engr-in-charge. |
| 166 | S&F in replacement of 20mm brass swing type NRV, including necessary fittings, complete all as specified and directed by Engr-in-charge. |
| 167 | S&F in replacement of 3KW SS heating element suitable for solar tank as per site requirement & model, complete all as specified and directed by Engr-in-charge. |
| 168 | S&F in replacement of hot/cold water vent pipe of 20mm dia all as per site requirement complete all as specified and directed by Engr-in-charge. |
| 169 | Supply & laying/fixing in replacement of 3 layered (outer green coloured UV stabilized, middle black coloured UV stabilized and innermost layer white coloured with anti-microbial property) fusion welded PP-R (polypropylene Random Co-Polymer) pipes, ISI marked including plain PP-R fittings and brass threaded PP-R fittings such as flanges, elbow, bend, sockets, tee etc. as required at site and testing of joints complete all as specified and as directed of size (a) PN-16, 32mm OD (SDR– 7.4) including all fittings complete all as specified and directed by Engr-in-charge. |
| 170 | All as per above item No: 169, but 25mm dia, complete all as specified and directed by Engr-in-charge. |
| 171 | All as per above item No: 169, but 20mm dia, complete all as specified and directed by Engr-in-charge. |
| 172 | S&F in replacement of PPR gate valve (brass insert) of size 32 mm dia including connection and testing complete all as specified and directed including taking out old unserviceable gun metal gate valve 50mm dia complete all as specified and directed by Engr-in-charge. |
| 173 | All as per above item No:172, but 25mm dia, complete all as specified and directed by Engr-in-charge. |
| 174 | All as per above item No: 172, but 63mm dia, complete all as specified and directed by Engr-in-charge. |
| 175 | S&F in replacement of Hot water pipe PUF insulation of GI/PPR pipe size 25mm complete all as specified and directed by Engr-in-charge. |
| 176 | M&L for disconnecting unserviceable solar water heater sytem including 4 nos of flat plate collector, hot water collector tank of 500LPD weighing approx 90/100kg tank, solar plate stand posts etc. including plumbing items and lowering down from rooftop of 4 storeyed bluildingand shifting to another 4 storeyed bluilding in other location by deploying suitable no of labour, T&P and transportation mode, complete all as specified and directed by Engr-in-charge. |
| 177 | M&L for brassing & gas welding of SS water tank & testing by filling water for 2 days as required on site complete all as specified and directed by Engr-in-charge. |
| 178 | M&L for disconnecting unserviceable solar water heater, hot water collector tank of 500LPDlowering it from stand after disconnecting water pipe line. unwraping corroded/damaged SS tank covering & insulation including replacing old insulation with new Aluminium sheet 10mm thick with rivets & screw as required at site & refixing, commissioning and testing of tank complete all as specified and directed by Engr-in-charge. |
| 179 | S&L in replacement of GI union with brass union 20mm dia between solar plates, complete all as specified and directed by Engr-in-charge. |
| 180 | S&F in replacement of Bib taps, cast copper alloy chromium plated 15mm dia with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed, complete all as specified and directed by Engr-in-charge. |
| 181 | M&L for periodically cleaning of solar flat plate collector with water & detergent properly and wiping it with cotton cloth & drying the plate glass, glass should crystal clear so that proper sunlight could be absorbed by plate, each solar heating system is of 500LPD with 4 Nos (2.15 mtx1.5mtr) flat plate collector once in every month, complete all as specified and directed by Engr-in-charge. |
| 182 | Painting of Solar structure with two coat of enamel paint with one coat red oxide complete all as specified and directed by Engr-in-charge. |
| 183 | S&F in replacement 150 WattLED floodlight made up of pressure die cast aluminium housing with toughened glass and high power LEDs and secondary lenses with IP66 protection, complete all as specified and directed by Engr-in-charge. |
| 184 | S&F in replacementwith Powder coated pressure die cast aluminium compact LED Street light/building lighting of 45 watt with toughened glass and high power LEDs with option of secondary optic with IP65 protection complete all as specified and directed by Engr-in-charge. |
| 185 | S&F in replacement of Lead Acid battery 150Ah, 12Volt, complete all as specified and directed by Engr-in-charge. |
| 186 | Supplying and laying in replacement ofsynthetic Rubber insulated mats 2 mm thick for voltage upto 3.3 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m complete all as specified and directed by Engr-in-charge. |
| 187 | M&L for making new ferrule in CI/DI pipe of any size, Straight plain brass ferrules (or connecting screws) screwed both ends and fixed of size 25mm dia including all fitiings, complete all as specified and directed by Engr-in-charge. |
| 188 | M&L for Cutting holes into or through cement concrete slabs, chajjas, etc. reinforced or otherwise is cut throughn exc 100 sqcm, complete all as specified and directed by Engr-in-charge. |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail