| 1 | Supply only refrigerant gas R-22 /32 or exisiting gas complete all as specified and directed by Engineer in Charge. |
| 2 | Supply only refrigerant gasR-407c complete all as specified and directed by Engineer in Charge. |
| 3 | Supply only refrigerant gasR-410 complete all as specified and directed by Engineer in Charge. |
| 4 | Supply only refrigerant gasR-134a complete all as specified and directed by Engineer in Charge. |
| 5 | Supply and fix in replacement of existing unserviceable outdoor unit of split type AC of 1.5 TR, Min 5 star rating, 4 in 1 invertor type capacity with compressor , copper condensor coil, fan motor completeetccomplete all as specified and directed by Engineer in Charge. |
| 6 | Supply and fix in replacement of existing unserviceable outdoor unit of split type AC of 2.0 TR, Min 5 star rating, 4 in 1 invertor type capacity with compressor , , copper condensor coil, fan motor etccomplete all as specified and directed by Engineer in Charge. |
| 7 | S & F in repair Starting Relay of for 2.0/1.5 Ton capacity Window/Split type AC\"s all as directed by Engineer in Charge. |
| 8 | S & F in repair Overload protector SR 1622 forWindow/Split type AC\"s all as directed by Engineer in Charge. |
| 9 | S & F in repair Starting capacitor of 80 to 100 MFDforWindow/Split type AC\"s complete all as specified and directed by Engineer in Charge. |
| 10 | S & F in repair Starting capacitor of 100 to 120 MFDforWindow/Split type AC\"s complete all as specified and directed by Engineer in Charge. |
| 11 | S & F in repair Running capacitor of 36 MFDforWindow/Split type AC\"s complete all as specified and directed by Engineer in Charge. |
| 12 | S & F in repair Running capacitor of 45/50 MFDforWindow/Split type AC\"s complete all as specified and directed by Engineer in Charge. |
| 13 | S & F in repair Thermostatic switch forWindow/Split type AC\"s complete all as specified and directed by Engineer in Charge. |
| 14 | S & F in repair Selector switch of rotary type forWindow/Split type AC\"s complete all as specified and directed by Engineer in Charge. |
| 15 | S & F in repair in replacementof double shaftor as per site requirment Blower fan motor suitable for 1.5/2.0 Ton capacity Window AC\"s complete as per existing make complete all as specified and directed by Engineer in Charge. |
| 16 | S & F in repair of Fan blade for 1.5/2Ton capacity Split type AC as per existing make and model complete all as specified and directed by Engineer in Charge. |
| 17 | S & F in repair of Air filter for window/split type AC 1.5/2 Ton as per existing make and model complete all as specified and directed by Engineer in Charge. |
| 18 | S & F in repair of Front grill for window type AC as existing make and modelcomplete all as specified and directed by Engineer in Charge. |
| 19 | Taking down carefully old burnt/unserviceable rotary compressor unit of 1.5 ton capacityand replacing the same with new rotarycompressor (i.e as per site requirenment) including necessary accessories i e capillary tube including strainer and mounting materials,etc, welding, brazing, leak testing, vaccumissing and charging the refrigerant gas to the required pressure and weight, reinstalling the AC unit on the same place including testing and commissioning complete to any make of AC all as directed by Engr-in-charge. |
| 20 | All as per Item No-19 here-in-before but of 2.0 Ton capacity reciprocation compressor complete all as specified and directed by Engineer in Charge. |
| 21 | All as per Item No-19 here-in-before but of 3.0 Ton reciprocation compressorcomplete all as specified and directed by Engineer in Charge. |
| 22 | Cleaning the unit with CTC except evaporator and condensor and leak testing the system with CO2 gas and detecting the leakwithNitrogen gas and repairing, brazing and sealing the leakage including charging the refrigerant R-22 gas to the required pressure and weight of gas for 1.5/2.0 Ton capacity window/split type AC of any make complete all as specified and directed by Engineer in Charge. |
| 23 | All as per Item No-22 here-in-before but of3.0(Multi unit)/5.0 Ton capacity window/split type AC complete all as specified and directed by Engineer in Chartge.Note: Gas charging will be measured against relevant item of this schedule |
| 24 | Servicing and overhauling the 1.5/2.0/3.0 Ton capacity (Window/Split) AC with water, chemical air clearner, filter and drying, checking the bolt and nut connections, filling, refixing /shifting/electrical loose connections and testing complete all as directed |
| 25 | S & FEvaporating coil made out of 25 SWG copper tubing having 30/34G aluminium fins per length for window AC\"s of 1.5/2.0 Ton capacity including taking out the unserviceable evaporating coil complete all as specified and directed by Engineer in charge. |
| 26 | S & FCondensor coil made out of 25 SWG copper tubing having 30/34G aluminium fins per CM length for window AC\"s of 1.5/2.0 Ton capacity indlcuding taking outthe unserviceable condensor coil complete all as specified and directed by Engineer in charge. |
| 27 | S & F Indoor unit of Split type AC of 1.5 TR, Min 5 star rating, 4 in 1 invertor type capacity suitable to existing Outdoor Unit including the necessary connections and testing complete all as specified and directed by Engineer in Charge. |
| 28 | All as per Item No-27 above but forSplit AC 2.0 TR capacity complete all specified and directed by Engineer in Charge. |
| 29 | Dismantling the water cooler and repairing the body by welding, brazing, riveting where required and making good of stand and bottom portion painting the body on external surfaces with one coat of synthetic paint over a coat of primer of same colour by machine spray and reassembling and installing in original position and testing complete all specified and directed by Engineer in Charge. |
| 30 | Cleaning all the parts, condensor unit and capillary tubes and checkng the leakage of gas with CO2 and brazing, rectifying the leakge, including charging the refrigerant gas to required pressure and weight fixing back to the original positon, testing comissioning complete for any make and any capacity of water cooler complete all as specified and directed by Engineer in Charge. |
| 31 | S & F inrepairs Relay Assembly for 40/80 Ltrs capacity Water Coolers of any make complete all as specified and directed by Engineer in Charge. |
| 32 | S & F inrepairsThermostatic Switch for 40/80 Ltrs capacity Water Coolers of any make complete all as specified and directed by Engineer in Charge. |
| 33 | S & F inrepairscopper wounded condenser fan Motor Single phase, 230V for 40/80 Ltrs capacity Water Coolers of any make complete all as specified and directed by Engineer in Charge. |
| 34 | S & F inrepairs Fan motor blade of any size/ model suitable for Water Coolers of any make complete all as specified and directed by Engineer in Charge. |
| 35 | S & F inrepairs Float valve 15 MM bore with brass spindle and PVC ball complete fof water cooler and PVC tanks Coolers of any make complete all as specified and directed by Engineer in Charge. |
| 36 | S & F inrepairs Push/lift tap 15 mm bore chromium plated for 40/80 Ltrs capacity Water Coolers of any make complete all as specified and directed by Engineer in Charge. |
| 37 | S & F inrepairs Overload protector 1022/522, for 40/80 Ltrs capacity Water Coolers of any make complete all as specified and directed by Engineer in Charge. |
| 38 | S & F inrepairs Starting/running Capacitor 60/80 Mfd, for 40/80 Ltrs capacity Water Coolers of any make complete all as specified and directed by Engineer in Charge. |
| 39 | Removing of defective condenser fan motor from water cooler rewinding of fan motor with same gauge and turns and weight of copper enameled wire and replacement of bearing and refixing, testing and commissioning of water coolers of any make complete all as specified and directed by Engineer in Charge. |
| 40 | Supply and fix in replacement of PVC water tank of minimum Three layers of cpacity 5000 ltrs, by disconnecting existing tank water connections remove it from PCC plinth and fixing of New PVC tank with all necessary water connections complete all as specified and directed by Engr in charge. |
| 41 | Taking out old burnt/unserviceable compressor unit ofwater cooler and repalcing the same with newcompressor of existing unit includingnecessary nuts, bolts, mounting materials, welding, brazing, leak testing and charging the refrigerant gas, R-22to the required pressure and weight, reinstalling in the same place including servicing, testing and commissioning complete to any make of water cooler of 40/80 Litre Capacity water cooler complete all as specified and directed by Engineer in Charge. |
| 42 | Taking out old burnt/unserviceable compressor unit ofwater cooler and repalcing the same with newcompressor of existing unit includingnecessary nuts, bolts, mounting materials, welding, brazing, leak testing and charging the refrigerant gas, R-22to the required pressure and weight, reinstalling in the same place including servicing, testing and commissioning complete to any make of water cooler60/120, 150/150 Litre Capacity water cooler complete all as specified and directed by Engineer in Charge. |
| 43 | S & F in drain tray and PVC flexible pipe and connecting to inlet pipe for 40/80 ltrs capacity of water cooler, including holdingclamps complete all as specified and directed by Engineer in Charge. |
| 44 | Servicing the water cooler of any make including cleaning the water tank, and the side body by washing, rubbing down including removing all the dust, dirt complete all as specified and directed by Engineer in Charge. |
| 45 | S & F inrepairs submersiable water pump motor as per existing capacity complete for desert coolers of any make complete all as specified and directed by Engineer in Charge. |
| 46 | S&F in repelcement Renewal of Fan motor withnew fan blade comple of desert cooler single phase, 215 Volts, AC, 50 Hz complete for desert coolers of any make complete for capacity 3000/4000 CUM complete all as specified and directed by Engineer in Charge. |
| 47 | S & F inrepairs Fan blade of desert cooler Metallic/PVC as per existing model complete for desert coolers of any make complete for capacity 3000/4000 CUM complete all as specified and directed by Engineer in Charge. |
| 48 | S & F inrepairs KHAS-KHAS grass (One set of three) as approved by Engr-in-charge, complete for desert coolers of any make complete for capacity 3000/4000 CUM complete all as specified and directed by Engineer in Charge. |
| 49 | S & F inrepairs PVC water tube and distribution with 3 way PVC connection,PVC bends assembly complete, for desert coolers of any make complete all as specified and directed by Engineer in Charge. |
| 50 | S & F inrepairs Caster wheels (Set of Four) complete, for desert coolers of any make complete for capacity 3000/4000 CUM complete all as specified and directed by Engineer in Charge. |
| 51 | S&F in repairs front grill of desert cooler of capacity 3000/4000 Cum of any make complete all as specified and directed by Engineer in Charge. |
| 52 | S&F in repairs switch assemblyfor desert coolers of capacity 3000/4000 Cum of any make complete all as specified and directed by Engineer in Charge. |
| 53 | S&F in repairs Capacitor of 4/5 MFD capacity suitable for fan motor of desert coolers of capacity 3000/4000 CFM of any make complete all as specified and directed by Engineer in Charge. |
| 54 | M&L for wiring to desert coolers with PVC insulated multistranded, copper conductor single core of size 1.5 Sqmm including PVC clamps, brackets as required and connection, water pump, control switches including taking down old wiring complete all as specified and directed by Engineer in Charge. |
| 55 | Supply and fix in repairs connection wire of 3 core copper wire PVC insulated of size 4 Sqmm for any capacity window type/Split type AC, water coolers/desert coolers complete all as specified and directed by Engineer in Charge. |
| 56 | S&F in repairs plug top 3 pin 5 Amps for desert cooler/water coolers/refrigerator complete all as specified and directed by Engineer in Charge. |
| 57 | S&F in repairs 3 pin industrial plug top suitable for industrial metal clad socket, single phase, 230 Volts, AC including reconnecting complete all as specified and directed by Engineer in Charge. |
| 58 | S&F in repairs copper tube of size 3/8\" / 5/8\" dia includng necessary soldering, flaring and connecting and testing in between indoor to out door units of split type AC 1.5 Ton complete all as specified and directed by Engineer in Charge. |
| 59 | All as per Item No 58 here-in-before but size of copper tubing 1/2\" / 1/4\" dia complete all as specified and directed by Engineer in Charge. |
| 60 | S&F in repairs nitrile rubber insulation pipes of suitable size for suction (discharge pipe) felt for split type AC 1.5 / 2.0/3.0 Ton copper tube as in inlet/outlet to out door unit complete all as specified and directed by Engineer in Charge. |
| 61 | S & Fix in repairs remote control assembly set suitable for split type AC 1.5 / 2.0/3.0 Ton capacity of any make complete all as specified and directed by Engineer in Charge. |
| 62 | S&F in repairs indoor blower motor for split type AC as per existing model, sample complete all as specified and directed by Engineer in Charge. |
| 63 | Taking down carefully existing serviceable split type AC unit of 1.5/2.0 TR capacity and shiftting to in another location and refixing in any position and height complete with all connected work like making holes, fixing mounting bracketsand all other requiredaccessories including making good the distrubed surfaces complete all as specified and directed by Engineer in Charge.Note :- Quoted rates deemed to included necessory core cutting on walls |
| 64 | S&F in repairs capillary tube including strainer suitable for split type AC 1.5/2.0 TR capacity with necessary brazing, leak testing complete all as specified and directed by Engineer in Charge. |
| 65 | S&F in repairs voltage stabilizer single phase, 230 Volts, AC, 50 Hz of capacity 4 KVA wall mounting typewindow type AC with low and high cut off and intelligent delay input voltage 160 Volts to 260 Volts complete all as specified and directed by Engineer in Charge. |
| 66 | All as per Item No-65 here-in-before but 5 KVA capacity voltage stabilizer complete all as specified and directed by Engineer in Charge. |
| 67 | Repair to stabilizer of 4KVA/5KVA capacity of Transformer including spares partsas required functional testing & reinstallaing after necessary repairscomplete all as specified and directed by Engineer in Charge. |
| 68 | Taking out unserviceable 1 Pole contactor from the split type AC and replacing the same asexistingwith new contactor suitable for 240V, 50Hz coil complete all as specified and directed by Engineer in Charge. |
| 69 | S&F in repairs 2 Pole contactor from the split type AC and replacing the same with new contactor suitable for 240V, 50Hz coil complete all as specified and directed by Engineer in Charge. |
| 70 | S&F in repairs drain pipefrom AC units complete all as specified and directed by Engineer in Charge. |
| 71 | S&F Brass Valves (set of 2 Nos) suitable for split type AC of capacity 1.5/2TR as per existig type including necessary brazing and sealing the leakage, Leak testing , charging the Refrigerant gas up to required pressure including taking down the unserviceable brass valves complete all as specified and directed by Engineer in Charge.Note :- Gas charging will be measured and paid under relevant item of this schedule. |
| 72 | S&F in repairs copper cable of size 3 core 2.5 Sqmm, PVC insulated sheathed, multistranded copper conductor complete all as specified and directed by Engineer in Charge. |
| 73 | Material and Labour for sub main wiring with 2 runs of 4 Sqmm single core PVC insulated unsheathed FRLS cable 1100 Volts grade multistranded with copper conductor drawn through and including non metallic rigid PVC conduit ISI marked 25 mm dia including conduit accessories concealed/surface type on walls, roof,floors etc including one run of 4.0 Sqmm PVC copper conductor as earth continuity wire includingtaking downunserviceable sub main wiring including conduitcomplete all as specified and directed by Engineer in Charge.Note : 2 Runs of 4 sqmm cable 1 run of 4 sqmm cable and 1 run of PVC conduit shall be measured as one unit for the purpose of payment. |
| 74 | All as per srl item No.91 here-in-before but with 2 runs 6 sqmmincluding 1 run of 6 sqmm PVC copper conductor FRLS cable as earth continuity wire in not less than 25mm dia PVC conduit.Note : 2 Runs of 6 sqmm cable 1 run of 6 sqmm cable and 1 run of PVC conduit shall measured as one unit for the purpose of payment. |
| 75 | S&F in repairs non metallic PVC conduit 20 mm dia inclusive of boxestees, bends, elbows, reducers, tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc complete all as specified and directed by Engineer in Charge. |
| 76 | S&F in repairs metallic AC earth plug and socket with sheet metal enclosure with MCB SP 20Ato 32 A complete all as specified and directed by Engineer in Charge. |
| 77 | Supply only capacitor 2.5 mfd suitable for ceiling fan and testing complete all as specified and directed by Engineer in Charge. |
| 78 | Supply only capacitor 3.5/ 4.0 mfd suitable for Exhaust fan/Wall mounted fan/Air Circulator Fan complete all as specified and directed by Engineer in Charge. |
| 79 | Taking down unserviceable desert cooler and supply, installation, testing, commissioning of New desert cooler of capacity 4500 Cum per hour made out of 01 mm thick galvanised steel sheet with complete fully exhaust fan 450 mm sweep, 1400 rpm motor and suitable capacity submersible pump and wood wool fitted in frame made from 25x25x3 mm angle iron and 25x25 mm size MS wire mesh net of 14swg dia fitted on both sides for supporting woodwool including suitable size top and bottom water tray made of 1.00 mm GIsheet 1000 watts speed control electronic regulator, suitbale size connection cable 3 core with copper conductor with moulded plug top, fan blade and all fixingaccessories complete all as specified and as direcd. Note : All electrical equipments shall be of BSI/ ISI Marks. |
| 80 | M&L fortaking down,repair of existing unserviceable of PCB of window/ spilt AC of 1.5/2.0/3.0 TR by replaceing its unsv parts make it fully functional and refixing the same on existing location complete all as specified and directed by Engineer in Charge. |
| 81 | M&L fortaking down,repair of existing unserviceable of PCBof invertor spilt AC of 1.5/2.0/3.0 TR by replaceing its unsv parts make it fully functional and refixing the same on existing location complete all as specified and directed by Engineer in Charge. |
| 82 | S & F in repalcement of existing unserviceable/burnt with New PCB of window/spilt AC of 1.5/2.0/3.0 TR of same makeby replaceing its unsv parts make it fully functional and refixing the same on existing location complete all as specified and directed by Engineer in Charge. |
| 83 | S & F in repalcement of existing unserviceable/burnt with New PCB of invertor type spilt AC of 1.5/2.0/3.0 TR of same makeby replaceing its unsv parts make it fully functional and refixing the same on existing location complete all as specified and directed by Engineer in Charge. |
| 84 | Supply and fix in replacement of existing unserviceable outdoor unit of split type AC of 1.5 TR ,with newone existingcapacity and makewith compressor , copper condensor coil, fan motor etccomplete all as specified and directed by Engineer in charge. |
| 85 | Supply and fix in replacement of existing unserviceable outdoor unit of split typw AC of 2.0 TR ,with newone existingcapacity and makewith compressor , copper condensor coil, fan motor etc complete all as specified and directed by Engineer in charge. |
| 86 | S & F in replacment Indoor unit of Split type AC of 1.5 TR with existing capacity and makecapacity suitable to existing Outdoor Unit including the necessary connections and testing etc complete all as specified and directed by Engineer in charge. |
| 87 | All as per Item No-86 above but forSplit AC 2.0 TR capacity complete all as specified and directed by Engineer in Charge. |