| 1 | Schedule \"A\" Part-I(BUILDING WORK) |
| 2 | Construction of PAR Hut complete all as specified and asshown on drawing. |
| 3 | Construction of POL store room complete all as specified and asshown on drawing. |
| 4 | Schedule \"A\" Part-II (PARKING SHED) |
| 5 | Lump sum price worked out by contractor for \"PARKING SHED ” as listed in Schedule ‘A’ Part- II. |
| 6 | Schedule \"A\" Part - III(INTERNAL ELECTRIC SUPPLY) |
| 7 | Lump sum price worked out by contractor for\"“INTERNAL ELECTRIC SUPPLY ” as listed in Schedule ‘A’ Part- III. |
| 8 | Schedule \"A\" Part - IV (INTERNAL WATER SUPPLY) |
| 9 | Lump sum price worked out by contractor for\"INTERNAL WATER SUPPLY ” as listed in Schedule ‘A’ Part- IV. |
| 10 | Schedule \"A\" Part- V(ROAD/ PATH/ CULVERT/ HARDSTANDING) |
| 11 | Lump sum price worked out by contractor for\"ROAD/ PATH/ CULVERT/ HARDSTANDING\" as listed inSchedule \"A\" Part- V. |
| 12 | Schedule \"A\" Part- VI(SEWAGE DISPOSAL) |
| 13 | Lump sum price worked out by contractor for\"(SEWAGE DISPOSAL\" as listed inSchedule \"A\" Part- VI. |
| 14 | Schedule \"A\" Part- VII(EXTERNAL ELECTRIFICATION) |
| 15 | Lump sum price worked out by contractor for\"EXTERNAL ELECTRIFICATION\" as listed inSchedule \"A\" Part- VII. |
| 16 | Schedule \"A\" Part-VIII(ALUMINIUM PARTITION) |
| 17 | Lump sum price worked out by contractor for\"ALUMINIUM PARTITION\" as listed inSchedule \"A\" Part-VIII. |
| 18 | Schedule \"A\" Part-IX(EXCAVATION AND EARTH WORK) |
| 19 | Lump sum price worked out by contractor for\"EXCAVATION AND EARTH WORK\" as listed inSchedule \"A\" Part-IX. |
| 20 | Schedule \"A\" Part-X(FLAME PROOF ITEMS) |
| 21 | Lump sum price worked out by contractor for\"FLAME PROOF ITEMS\" as listed inSchedule \"A\" Part-X. |
| 22 | Schedule \"A\" Part -XI(MISCELLANEOUS ITEMS) |
| 23 | Material and labour for point wiring complete, stranded copper conductor1.5 Sqmm nominal area PVC insulated FRLS 1100 volts grade electrical cable in and including concealed PVC medium grade conduit and 20 mm dia including provn of appropriate size of modular metal flush boxes concealed with modular natural/ white finish front plate with base plate for the mounting of modular switches and sockets 1.5 sqmm stranded copper conductor PVC sheathed cable earth wire to common earth and connected to earth dolly complete all as specified for following: |
| 24 | All as per Srl item No 11.01 above for one light /fan point controlled by one way switch |
| 25 | All as per Srl item No 11.01 above for one 3 pin socket outlet 6 amps on independent board |
| 26 | All as per Srl item No 11.01 above for one 3 pin socket outlet 6 amps pointon same board |
| 27 | All as per Srl item No 11.01 above one 3 pin socketoutlet , 15 amps on independent board with cable 2.5 Sqmm and 2.5 Sqmm as earth wire. |
| 28 | Supply & fixing LED tube light fitting, 40W, 4 feet long, complete with all accessories internally pre-wired and including connecting up with three core twisted flexible copper conductor cable with suitable size completeall as specified and directed. |
| 29 | Supply and fixing 3mm thick high quality, durable Acrylic panel sheet and glazing with rubber beads, clips etc complete all as specified and directed. |
| 30 | Supply and fix air cooled, Inverter type split unit air conditioner electric driven single phase copper condenser of capacity of 2.0 TR, BEE 5 star rated complete all as specified and directed by Engr-in-Charge. |
| 31 | Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor wall mounted type & designed for input variation between 130 V to 300 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA complete all as specified and directed by Engr-in-Charge. |
| 32 | S&F switch flame proof,zone I & II, Gas Group II A/ II B,weather proof rotary type with termination box in LM6 10A single pole 250 V complete all as specified and directed |
| 33 | Supply & fix flame proof,zone I & II, Gas Group II A/ II B, weather proof exhaust fan 300mm sweep, cast iron body, grey finished including suitable size louver complete all as specified and directed. |
| 34 | Supply & fix flame proof,zone I & II, Gas Group II A/ II B, weather proof DB SPN 220 volts 4 way with busbar in cast aluminium LM-6 enclosure operated externally spring type knob complete with suitable incoming and outgoing cable entries with cable glands suitable for hazardous area and confirming to IS-2147/62 neoprene gasket degree of protection IP 65 suitable forMCB SPN 25 Amps -01 No. as incomer (b)MCB SP 6 Amps - 2 Nos as outgoing complete all as specified and directed. |
| 35 | Supply and fixing polyethylene septic tank (cylindrical) of overall size 2.8 (length) x 1.00 mtr dia of wall thickness 10 mm with 3 Nos chambers, 2 nos manholes of dia 110 mm size with 30-35 per day flushing capacity of teracota colour complete includingexcavation in any type of soil, PCC 1:4:8 below foundation, vent shaft, connection etc complete all as specified. (unit rate of this item includes of cost of excavation, earth wor and PCC in foundation) complete all as specified and as directed by Engineer-in-Charge. |