Bids Are Invited For Custom Bid for Services - Regular Electrical and civil works At Erpl Allahabad Pump Station - MANPOWER COMPONENT: Wages of one (01) unskilled man powers to be paid monthly for maintaining lawns, gardens, housekeeping of station etc. It includes minimum basic wages (including additional payment for PF,ESI and Bonus) - (Fixed item) MANPOWER COMPONENT: Providing one set of liveries to one manpower in one year (A)Cotton uniform: Two sets of shirt and trousers. (B)One pair of Safety shoes (Karam FS 05 or Bata Industrial Endura LC/ST equivalent; Standard: Conforming to IS 15298:2011 & DGMS and two pair of socks (C) One No. Full Sleeve Sweater for winter season.- (Fixed item) MANPOWER COMPONENT: Overhead cost per month to contractor for providing one (01) no.s of unskilled manpower including profit for maintaining lawns, garden etc. (Quotable item) SAFETY EQUIPMENT: RUBBER HAND GLOVES: Rubber hand gloves suitable for 11/6.6 KV operation with ISI mark-(Quotable item) SAFETY EQUIPMENT: Supply and installation of 11/6.6 KV Discharge Rod-(Quotable item) LT Cable joint (1.1 KV)-Making straight through joints on Al/Cu conductor XLPE/PVC insulated armoured cable including the supply of required materials such as cable jointing kit (of heat shrinkable sleeve type of Raychem/Mseal/3M), materials, labour, tools and tackles, consumables etc, as per drawings, specification and directions of Site Engineer/Engineer-in-Charge Power cables LT: OD upto 20 mm (Quotable item) Power cables LT: OD above 20 mm and upto 40 mm-(Quotable item) Supplying, installation, testing of Gl earthing electrode, including the supply and installation of the cover, charcoal/special backfill etc. and construction of chamber, complete as per drawings, specifications and directions of the Site Engineer, Including the cost of all labour, tools, materials etc. complete in all respects (Quotable item) EARTH STRIP/WIRE/ROPE/CABLE-Supply, installing and testing of earthing strip/wire/rope/cable for completely making the earthing grid system by supplying, lay rig the 61/ Cu strip and making all the necessary welding joints, connecting to the earthing electrodes and existing earthing grid etc., complete as per drawings, specifications and directions of the Site engineer/Engineer-in-charge, including the cost of all labour, tools, materials, etc. complete in all respect 40 mm X 5 mm Ga, earthing strip- (Quotable item) Copper cable as per specifications-10 Sq.mm- (Quotable item) FLAMEPROOF LED WELL GLASS FITTING 125 W, Supply, installation, testing & commissioning of Exd (Flameproof) Well Glass Light Fixture with provision of Cable Entries: 2 Nos. x 3/4 ET, Cable Glands: 2 Nos. x 3/4 ET (Max. OD 20mm)- Exd(A/B), Double Compression type, Brass Nickel Plated with PVC Hood. Blanking Plug: 1 No. x 3/4 ET-Exd, Brass Nickel Plated. Gasket: Neoprene, Hardware: SS 304, Earthing: External 2 Nos. (M6), Internal 1 No. (MS), and as per attached detailed technical specification- (Quotable item) PVC Conduit pipes-Supply, installation, fixing in position, PVC conduit pipes, of ISt marked, in concrete, brick work etc. during or after construction by making grooves in the wall, ceiling etc. cutting threads and jointing the pipes with PVC couplers, providing necessary tees, bends, junction boxes etc. with 12 SWG GI wire Inside conduit without joint for cornicealed wiring including making good the concrete, brick work, surfaces etc. complete as per drawings and direction of Site Engineer/Engineer-in-charge including cost of all labour, materials etc.-25 mm (Quotable item) TRANSFORMER OIL: Centrifuging, filtering and dehydrating of the transformer oil of transformer to improve insulation level to the value recommended as per the relevant ISS and the manufacturers recommendations and as per specifications and directions of the Site Engineer/Engineer-in-Charge including supply of labour, tools and materials and all services rendered complete -(Quotable item) Overhauling and painting of WAC, SAC, WC B Cold Storage of different make & different capacities located at various location within the Station premises, Station township and air monitoring stations, job includes removal of machines from location, dismantling, cleaning, washing, chemical cleaning of condenser & cooling coil, overhauling, lubrication of blower motor, checking, repair/rectification/replacement of effective control component. Painting of all metal part and chassis cover internal painting with primer & outer painting with synthetic enamel paint Cleaning of coil & condenser to be done with wire brush. Delective/damage insulation to be replaced. All the electrical wires must be dressed properly. Defective wires to be replaced including supply of wires. Defective/damage asbestos sheet to be replaced. Asbestos sheet shall be provided by the owner. Cleaning/replacement of filter by Nylon filter. Re-assembly of machine, shifting to location & testing of machine. Job complete in all respect including men & material and as per direction and instruction of Site Engineer/Engineer-in- Charge- (Quotable item) Gas charging of air conditioner upto 1.5ton capacity with job involved transportation of machine to vendors works. Checking of all components for leak by charging co2 gas & finally evacuating the compressor completely & charges of refrigerant gas - 22. A- (Quotable item Overhauling of exhaust/air circulator fans of various types/sizes makes and its bearings including removal from site, cleaning, greasing after degreasing, assembling and fixing in position, testing and commissioning including transportation from site to workplace and back all complete with labour and materials as per directions of Engineer-in-Charge: including supply and fixing of bearings of SKF make (02 Nos. bearings)-(Quotable item) REWIINDING OF FANS Rewinding of ceiling/pedestal/exhaust/air circulator fans of all types/sizes/make including 1-phase and 3-phase type exhaust fans max. upto 2.2 KW capacity and supply of super enameled winding wire (Devi Dayal make, 151 marked insulation materials required). This also includes replacement of single/double bearing SKF make/bushes (as per original make) and overhauling of fan and all jobt related to complete this work in totality. This also includes removal of fans from site, installation and commissioning after testing of rewound fans and replacement of condenser, if required. This also includes transportation from site after dismantling to Contractors workshop and back to site. Note: Contractor has to give guarantee for rewinding of above items for a period of six months and if winding is burnt again within six months of working of fans, it has to be rewound again of Contractor. The burnt winding shall be kept by Contractor (Quotable item) Supply, fixing in position, installation, connection, testing and commissioning of the following LED Light Fittings rated for 240V, 50Hz, 1-phWC fo the make of Philips/Osram/Havells/Wipro/Bajaj/Eveready/SY SKA/Oreva/Crompton or equivalant indian make). Item includes Installation & Connection of Lighting Fixture on Existing Poles/HMT/FLT, Metallic Structures, Walls, Buildings, Roofs, Sheds and other facilities upto a height of 30m, removal of the, Complete in All respect with Materials, Transportation, Labor, Tools etc.: 90W, LED Street Light Fighting weatherproof, 230V AC, 50Hz (Quotable item) Cable Laying - Laying of all type of cables LT (PVC / XLPE / Armoured/Unarmoured/Power/ Control/ Signalling) in trenches, in cable racks, in trays, in protective pipes, poles, columns, in conduits, in panels and on structures etc.; including the supply and installation of all required materials such as fixing clamps, screws, cable straps, tags, etc. as required (other than the supply of the conduits, cables, pipes, cable racks, trays, poles, structures and panels) complete in all respect, including cost of all labour, tools, consumable materials, etc. and cutting the cables in required lengths as per drawings, specification and directions of Site Engineer / Engineer-in-Charge Power cables LT: OD upto 20 mm (Quotable item) Power cables LT: OD above 20 mm and upto 40 mm (Quotable item) Excavating trenches of required width in all kinds of soil for pipes, cables, etc. including excavation for sockets, and dressing of sides, ramming of bottoms, upto specified depth, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cman depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil, all work up to any lead & lift as directed by the Engineer-in Charge: Trench depth upto 1.5m Pipes, cables etc. not exceeding 80 mm dia. (Quotable item) Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 Itr/10 sam over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture. - (Quotable item) Lettering with black lapan paint of approved brand and manufacture. (Note: Unit EA shall mean PER LETTER PER CM HEIGHT). (Quotable item) Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering-All work up to plinth level :1:1.5:3 (1 cement: 1.5 coarse sand (zone-III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources)-(Quotable item) Repair to plaster of thickness 12 mm to 20 mm in patches of area up to 2.5 SQM including cutting the patch in proper shape, raking out joints, preparing and plastering the wall surface etc. complete, including disposal of rubbish at unobjectionable area outside Ownders premises, all complete as per directions of the Engineer-in-Charge :With cement mortar 1:4 (1 cement : 4 fine sand) - (Quotable item) Cleaning of terrace/ loft water storage tank (inside surface area) up to 2000 litre capacity at all heights with coconut brushes, duster etc., removal of silt, rubbish from the tank and cleaning the tank with fresh water disinfecting with bleaching powder @ 0.5gm per litre capacity of tank, including marking the date of cleaning on the side of tank body with the help of stencil and paint and disposing of malba, all complete as per the directions of Engineer-inCharge. [Note: The old date already written on tank should be removed with paint remover or black paint and if date is not written with the stencil or old date is not removed deduction will be made @ Rs. 0.10 per litre if during cleaning any G.I. fittings or ball cock is damaged that is to be repaired by the Contractor at his own cost and nothing extra will be paid on this account] - (Quotable item) Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead :For thickness of tiles 10 mm to 25 mm- (Quotable item) Providing and laying Glazed Vitrified Tiles (Matt/ Antiskid finish) of specified sizes (thickness to be specified by the Manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacture, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 Kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only. Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, levelling system and rubber mallet for placing the tiles gently and easily :Size of Tile 600 x 600 mm- (Quotable item) Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS:1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :125 mm- (Quotable item) Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS:6315, having brand logo embossed on the body/ plate with double spring mechanism and door weight up to 125 Kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per directions of the Engineer-in-Charge. :With brass cover plate minimum 1.25 mm thickness- (Quotable item) Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber/ neoprene gasket etc. complete as per the architectural drawings and directions of the Engineer-in-Charge. [Note: Cost of aluminium snap beading shall be paid in basic item] :With float glass panes of 4.00 mm thickness- (Quotable item) Supplying at site, steel structural items such as steel plates, bars, MS gratings, chequered plates, angles, beams channels, commercial quality heavy pipes, C.I. Rollers, bolts & nuts, washers, grouting bolts, padding plates etc., fabrication and erection of saddle supports and other type of supports for pipes manifolds and valves, fabrication and erection of platforms walkways, stairways etc., sand blast/ power brush cleaning, priming and painting the finished structures including supply of all other inputs such as labour, materials, consumable etc. necessary to perform and complete the work in all respect, in accordance with drawings, specifications and instructions of the Site Engineer / EIC. - (Quotable item Providing and fixing 15mm diameter C.P. brass tap as per following with C.P. brass flange including cutting & making good the walls wherever required, etc. complete in all Total Quantity :