E-TENDER FOR COMPREHENSIVE A.M.C. INCLUDING OPERATION & MAINTENANCE 11KV/0.433KV ELECTRICAL SUB-STATION WITH D.G SETS WORK FOR 5 YEARS AT INDIAN INSTITUTE OF MANAGEMENT LUCKNOW, NOIDA CAMPUS, PLOT NO-B-1, SECTOR-62, NOIDA-201 307 (UP); 1 OPERATION & MAINTENANCE 2 Operation and maintenance of the 11KV/ 0.433KV electrical substation 1&2 with allComponents. 3 Operation and day-to-day maintenance of 5 Nos. D.G Sets (2 no. 500 KVA and 2 no. 250 KVA DG Sets & 1 No. 320 KVA DG sets.) 4 Maintenance of the internal electricalInstallation of all the buildings in the campus. 5 Maintenance of the ElectricalFitting/Installation on all side roads, compounds. 6 PREVENTIVE MAINTENANCE - The schedule for Preventive maintenance of substation consisting of 5 Panel 11 KV HT Board, 3 Nos. 1000 KVA Transformers, Bus Ducting, LT Panels, Earth sets and cable terminations etc. While all specialized tools/plants/instruments required for preventive maintenance are included, any material required for repair/replacement of any items is not included, for which additional payment will be made after verifying the rate. The entire job will be done under the supervision of a qualified/ licensed Engineer and work will be done as per the manufacturer’s recommendations and best engineering practice. 7 Electrical Substation 8 Servicing of 5 Panel 11 KV HT Panel including general cleaning, relay lubrication as per manufacturers recommendations and meter/ relayTesting and calibration with primary/ secondary injection test. 9 TransformerOilfiltration,dehydrationandtopping up Buckholtz Relay testing, checking of LT/ HT earth terminations, Di-electric testing,insulation testing, general servicing ofTransformer. 10 Transformer Oil Topping, Supply and topping up oil. 11 LT Sub Panel (Power/light supply panel & AC plant panel) – cleaning, tightening of bolts examination of insulation and checking of proper termination of bus ducting of the all building &street light panel at Noida Campus 12 LT Bus Ducting – Opening, cleaning, tightening of bolts examination of insulation and checking of proper termination of bus ducting of the entire substation. 13 LT Panel – Capacitor panel servicing: Opening, cleaning, tightening of all bolts, checking proper termination of all cables, checking working of indication and measuring instruments. 14 Servicing and relay testing of all ACB’s of LT panels and servicing of all MCCB’s/ Switches and ensuring proper contact cleaning and termination of cables (once six months beforeDue date). 15 Identifying the earth electrodes of all transformer neutrals, DG set neutrals, Body earthling and providing new earth pit covers and taking earthTesting measurements of all earth tests. And all building panel point. With required man power. 16 GI Plate earting of size 600x600x3mm earthing with top funnel 1.25 inch GI pipe earth electrode with GI nut bolt and washer with earth pitt cover complete as per CPWD specifications 17 Suppllying and laying of GI strip 25x3mm and connecting the same with eath pit and upto the required site as per requirement 18 Suppllying, Installation and testing of spares FRCD of bus coupler for CNCS 1600AMP ACB (make L&T) 19 Painting of substation equipment’s to include HT Panels, Transformers, Bus-Ducting, LT Panels, Capacitor Panels, DG Set Acoustic enclosure and substationoutdoorwiremeshfencingafterThoroughly cleaning the surface of all equipment’s with superior paint as approved. 20 Painting of substation walls/ ceiling & with OilBound Distemper. Fancy Jal of substation-01 &02 21 Road/ Compound Lights/ Garden Lights 22 Painting of all poles, marking, cleaning of all fittings, and repair of Central Switchgear of Pole.( once in a Year ) 23 Proper setting of loose electrical wires and cleaning of electrical installations inside the panel rooms (once in a year) 24 Providing and making route marker sign plates for HT lines from meter panel to buildings and substation at every 10 meter interval with height1.5 feet. 25 Providing & fixing 33 KV rubber mat 914.4 mm wide and 15 mm thick to withstand 11 KVDielectric strength. 26 Supply & installation of exide battery heavy duty 180AH (12 vlot) with brass terminal complete connection for DG sets 27 Replacement of incomer power supplyincomer switch (DTH 800MCCB 415 VOLT 50 KA ) of 500 KVA DG Setat substation-01 28 Procurement of ON LINE UPS 1 KVA with inbuilt Batterysystem for power supply of PLC panel at substation -01 29 Replacement of Under Voltage Relay & Timer Switch in main LT panel at Substation -01 30 Supply and installation of 400 AMP three pole 50KA MCCB make (L&T) 31 Supply and installation of 200 AMP three pole 50KA MCCB make (L&T) 32 Supply and installation of 800 AMP three pole 50KA MCCB make (L&T) 33 Supply and installation of 630 AMP three pole 50KA MCCB make (L&T) 34 Supply & replacement of damaged LT ACB Front Fascia. 35 Servicing of Geyser 25 Liter at IPMX Hostel/MDP/Faculty Housing/other locations at Campus 36 Repairing &Replacement ofElement, relay, thermostate, seal packing of Geyser 25 Litre(Make: bajaj/other make) 37 Repairing, servicing of water cooler including gas charging, olp, relay, filter, gate valve replacement. 38 Repairing of Fly catcher machine including tube replacement. 39 Repairing and Rewinding of Motor of pedestal fan(12 inch),Lift fan & Exhaust fan(washroom) 40 Repairing, rewinding, servicing, shaft replacement of 2 HP/3HP/5 HP pump/motors of STP,Pump House & other locations. 41 Repairing & servicing of mercury heater including tube replacement, mercury holder and other works. 42 Earthing with copper earth plate 600 mm x 600 mm x 6 mm thick including accessories and providing masonry enclosure with cove plate having locking arrangement and watering pipe of 2.7 metere long with charcoal/coke and salt as required. 43 Supply & laying 25 mm x 5 mm copper strip at 0.50 meter below ground as strip earth electrode including connection/termination with nut,bolt,spring,washer etc as required. 44 Supply and fixing of Exhaust fan in PLC panel