}

Bids Are Invited For 1. 415V, Utilization Category Ac-23A, 630A Local Isolator Cabinet In Sheet Steel Enclosure Complete With 630A, 3 Pole Load Break Switch. 2. Shall Be With Side Operated Handle, Padlocking Facility, Pre-Break Micro Switch Having 1No+1, Damanjodi-Odisha

Boards / Undertakings / PSU has published Bids Are Invited For 1. 415V, Utilization Category Ac-23A, 630A Local Isolator Cabinet In Sheet Steel Enclosure Complete With 630A, 3 Pole Load Break Switch. 2. Shall Be With Side Operated Handle, Padlocking Facility, Pre-Break Micro Switch Having 1No+1. Submission Date for this Tender is 27-08-2024. Miscellaneous Fasteners Tenders in Damanjodi Odisha. Bidders can get complete Tender details and download the document.




Tender Notice

44915194
Bids Are Invited For 1. 415V, Utilization Category Ac-23A, 630A Local Isolator Cabinet In Sheet Steel Enclosure Complete With 630A, 3 Pole Load Break Switch. 2. Shall Be With Side Operated Handle, Padlocking Facility, Pre-Break Micro Switch Having 1No+1
Open Tender
Indian
Odisha
Damanjodi
27-08-2024

Tender Details

Bids Are Invited For 1. 415V, Utilization category AC-23A, 630A Local Isolator Cabinet in sheet steel Enclosure complete with 630A, 3 Pole load break switch. 2. Shall be with side operated handle, padlocking facility, pre-break micro switch having 1NO+1NC contact. 3. Micro switch contacts shall be wired to 4 sq mm TB for external termination. 4. Provision of Padlock system having sufficient space to lock the Isolator at OFF position by minimum two agencies at a time. 5. Complete with both power & control circuit wiring with all insulators, bus bars and control terminal blocks. 6. Detachable bottom gland plate for entry of cables from bottom. 7. Front door shall be hinged and inter-locked with the isolator in ON position. The front door should have a minimum 3 mm thickness Perspex/Triplex window for observation of position of contacts. 8. Isolator should confirm to IEC 60364 standard. 9. The dimensional drawing of the local isolator cabinet or product catalogue showing mounting arrangement of the components should be enclosed along with the offer. 10. Isolator cabinet should be provided with rain canopy. 11. Any isolator parts should not be made of aluminium/aluminium alloy. 12. Isolator cabinet shall be metal enclosed suitable for wall fixing using 4 welded fixations, dust and vermin proof and shall be provided with degree of protection as IP-55. 13. Provision for three distinct parallel busbar per phase for termination of three nos of 240 sqmm Aluminum cables for incoming and two distinct busbar per phase for termination of 120 sqmm copper cable. 14. All hardware used in Isolator cabinet shall be corrosion resistant. 15. Minimum clearance between the live parts and detachable bottom cable gland plate shall be 400mm. 16. Cabinet should be painted with alkaline resistant Epoxy paint. 17. Isolator cabinet shall have provision for earthing at two separate and distinct points. 18. Each isolator cabinet should be supplied with panel keys. 1. 415V, Utilization category AC-23A, 40A Local Isolator Cabinet in sheet steel Enclosure complete with 40A, 3 Pole load break switch. 2. Shall be with side operated handle, padlocking facility, pre-break micro switch having 1NO+1NC contact. 3. Micro switch contacts shall be wired to 4sqmm TB for external termination. 4. Provision of Padlock system having sufficient space to lock the LIC at OFF position by minimum two agencies at a time. 5. Complete with both power & control circuit wiring with all insulators, bus bars and control terminal blocks. 6. Detachable bottom gland plate for entry of cables from bottom. 7. Front door shall be hinged and inter-locked with the isolator in ON position. The front door should have a minimum 3 mm thickness Perspex/Triplex window for observation of position of contacts. 8. Isolator should confirm to IEC 60364 standard. 9. The dimensional drawing of the local isolator cabinet or product catalogue showing mounting arrangement of the components should be enclosed along with the offer. 10. Isolator cabinet should be provided with rain canopy. 11. Any isolator parts should not be made of aluminium/aluminium alloy. 12. Isolator cabinet shall be metal enclosed suitable for wall fixing using 4 welded fixations, dust and vermin proof and shall be provided with degree of protection as IP-55. 13. All hardware used in Isolator cabinet shall be corrosion resistant. 14. There shall be sufficient clearance between the live parts and detachable bottom cable gland plate. 15. Cabinet should be painted with alkaline resistant Epoxy paint. 16. Isolator cabinet shall have provision for earthing at two separate and distinct points. 17. Each isolator cabinet should be supplied with panel keys. 1. 415V, Utilization category AC-23A, 160A Local Isolator Cabinet in sheet steel Enclosure complete with 160A, 3 Pole load break switch. 2. Shall be with side operated handle, padlocking facility, pre-break micro switch having 1NO+1NC contact. 3. Micro switch contacts shall be wired to 4sqmm TB for external termination. 4. Provision of Padlock system having sufficient space to lock the LIC at OFF position by minimum two agencies at a time. 5. Complete with both power & control circuit wiring with all insulators, bus bars and control terminal blocks. 6. Detachable bottom gland plate for entry of cables from bottom. 7. Front door shall be hinged and inter-locked with the isolator in ON position. The front door should have a minimum 3 mm thickness Perspex/Triplex window for observation of position of contacts. 8. Isolator should confirm to IEC 60364 standard. 9. The dimensional drawing of the local isolator cabinet or product catalogue showing mounting arrangement of the components should be enclosed along with the offer. 10. Isolator cabinet should be provided with rain canopy. 11. Any isolator parts should not be made of aluminium/aluminium alloy. 12. Isolator cabinet shall be metal enclosed suitable for wall fixing using 4 welded fixations, dust and vermin proof and shall be provided with degree of protection as IP-55. 13. All hardware used in Isolator cabinet shall be corrosion resistant. 14. Minimum clearance between the live parts and detachable bottom cable gland plate shall be 200mm. 15. Cabinet should be painted with alkaline resistant Epoxy paint. 16. Isolator cabinet shall have provision for earthing at two separate and distinct points. 17. Each isolator cabinet should be supplied with panel keys. 415V, Utilization category AC-23A, 400A Local Isolator Cabinet in sheet steel enclosure complete with 400A, 3 Pole load break switch with side operated handle, padlocking facility, pre-break micro switch having 1NO+1NC contact, complete with both power & control circuit wiring with all insulators. Bus bars and control terminal blocks, detachable bottom gland plate for entry of cables from bottom. Front door shall be hinged and inter-locked with the isolator in ON position. The front door should have a minimum 3 mm thickness Perspex/Triplex window for observation of position of contacts. Note: 1. Isolator should confirm to IEC 60364 standard. 2. The dimensional drawing of the local isolator cabinet or product catalogue showing mounting arrangement of the components should be enclosed along with the offer. 3. Isolator cabinet should be provided with rain canopy. 4. Any isolator parts should not be made of aluminium/aluminium alloy. 5. Isolator cabinet shall be metal enclosed suitable for wall fixing using 4 welded fixations, dust and vermin proof and shall be provided with degree of protection as IP-65. 6. All hardware used in Isolator cabinet shall be corrosion resistant. 7. Minimum clearance between the live parts and detachable bottom cable gland plate shall be 300mm. 8. Cabinet should be painted with alkaline resistant Epoxy paint. 9. Isolator cabinet shall have provision for earthing at two separate and distinct points. 10. Each isolator cabinet should be supplied with two panel keys. Total Quantity : 45

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail