}

Dr.B.R.Ambedkar Memorial Hospital Raipur (C.G.) Invites E-Tender For Supply Of Implant Ctvs 2024 Item On Rate Contract Basis To Hospital For A Period Of One Year. Tender Document Containing The Detailed Terms Conditions May Be Viewed And Obtained From Htt-Chhattisgarh

Government Departments has published Dr.B.R.Ambedkar Memorial Hospital Raipur (C.G.) Invites E-Tender For Supply Of Implant Ctvs 2024 Item On Rate Contract Basis To Hospital For A Period Of One Year. Tender Document Containing The Detailed Terms Conditions May Be Viewed And Obtained From Htt. Submission Date for this Tender is 20-09-2024. Uniform Tenders in Chhattisgarh. Bidders can get complete Tender details and download the document.




Tender Notice

44836772
Dr.B.R.Ambedkar Memorial Hospital Raipur (C.G.) Invites E-Tender For Supply Of Implant Ctvs 2024 Item On Rate Contract Basis To Hospital For A Period Of One Year. Tender Document Containing The Detailed Terms Conditions May Be Viewed And Obtained From Htt
Open Tender
Indian
Chhattisgarh
20-09-2024

Tender Documents

Tender Details

Dr.B.R.Ambedkar Memorial Hospital Raipur (C.G.) Invites E-Tender For Supply Of Implant Ctvs 2024 Item On Rate Contract Basis To Hospital For A Period Of One Year. Tender Document Containing The Detailed Terms Conditions May Be Viewed And Obtained From Https://Eproc.Cgstate.Gov.In-1 ADJUSTABLE NOVA CLIP Adjustable Spring clip,Latex Free, Light weight,Adjustable Occlusive force settings,Radopaque components,Should be compatible with fogarty clip applicators Each 2 ARTERIAL FILTER ADULT 40 m Polyster screen filter,Max. blood flow 6 L/min.,Priming volume of 100 ml.Excellent air handling,Excellent visibility & easy priming Each 3 ARTERIAL FILTER INFANT 40 m Polyster screen filter,Max. blood flow 3 L/min.Priming volume of 28 ml.,Excellent air handling,Excellent visibility & easy priming Each 4 ARTERIAL FILTER PEDIATRIC 40 m Polyster screen filter,Max. blood flow 3 L/min.,Priming volume of 28 ml.Excellent air handling,Excellent visibility & easy priming Each 5 BULLDOG CLAMP WHITE BULLDOG CLAMP MEDI CURVED 45 Degree WHITE,Lightweight, cost-effective, plastic construction,Single-use, sterile packaged,Atraumatic – jaw designs Each 6 BULLDOG CLAMP YELLOW BULLDOG CLAMP MEDI CURVED 45 Degree YELLOW,Lightweight, costeffective, plastic construction,Single-use, sterile packaged,Atraumatic – jaw designs Each 7 BULLDOG CLAMP WHITE BULLDOG CLAMP MEDI STRAIGHT 90 DEGREE WHITE,Lightweight, costeffective, plastic construction,Single-use, Each 13 13 sterile packaged,Atraumatic – jaw designs 8 BULLDOG CLAMP YELLOW BULLDOG CLAMP MEDI 90 DEGREE YELLOW Each 9 C.V.C. 1LUMEN 22GA X 13CM,C.V.C 2L, 4FR X 6CM,C.V.C 2LUMEN 7FR X 16CM,C.V.C 3LUMEN 4.5FR X 6CM C.V.C 3L 5.5FR X 8CM,C.V.C 4LUMEN 8.5FR X 10CM,C.V.C 4L, 8.5FR X 13CM,C.V.C 4L, 8.5FR X 16CM,C.V.C. 3L, 4.5FR X 6CM,C.V.C 3LUMEN 7FR X 10 CM,C.V.C. 3L, 7FR X 13 CM,C.V.C. 3L, 7FR X 16 CM Central Venous Catheter made of specially formulated and biocompatible Polyurethane material provides strength during insertion and also softens at body temperature to conform to the body tissues and reduces the risk and vascular trauma.,Specially designed soft & beveled tip for smooth & easy insertion of catheter,Soft Flexible J -Tip Guide wire prevents the vessel perforation and also provides good torque to ensure firm insertion,Sufficiently radio - Opaque material of catheter with clear, definite marking facilitates correct placement of catheter tip,Sterile ready for use & Individually tray packed Each 10 CAUTERY TIP CLEANER Intended to assist in cleaning and removing of material from cautery tips during surgical procedures,Strongly adheres to both disposable and reusable drapes, Radiopaque,Sterile Each 11 CHEST DRAINAGE BOTTEL 500ML Closed System with separate filling / vacuum port 500ml,Ensures that sterility is not lost while filling water in the product,Pre -connected Patient Line,Over - flow design,Absolutely Transparent,Rigid Reservoir assures ZERO - COLLAPSABILITY during vacuum,Sloped bottom, yet standing flat Each 14 14 12 CHEST DRAINAGE BOTTLE 1200ML Closed System with separate filling / vacuum port 1200ml,Ensures that sterility is not lost while filling water in the produc,Pre-connected Patient Line,Overflow design,Absolutely Transparent,Rigid Reservoir assures ZEROCOLLAPSABILITY during vacuum,Sloped bottom, yet standing flat. Each 13 CHEST DRAINAGE BOTTLE 2000ML Closed System with separate filling / vacuum port 2000ml,Ensures that sterility is not lost while filling water in the product,Pre-connected Patient Line,Overflow design,Absolutely Transparent,Rigid Reservoir assures ZEROCOLLAPSABILITY during vacuum,Sloped bottom, yet standing flat Each 14 EMBELECTOMY CATHETER 2FR (Ballon Sizes of catheter : 4mm-20mm. Catheter Size 2Fr) EMBELECTOMY CATHETER 3FR (Ballon Sizes of catheter : 4mm-20mm. Catheter Size 3Fr) EMBELECTOMY CATHETER 4FR (Ballon Sizes of catheter : 4mm-20mm. Catheter Size 4Fr) EMBELECTOMY CATHETER 5FR (Ballon Sizes of catheter : 4mm-20mm. Catheter Size 5Fr) EMBELECTOMY CATHETER 6FR (Ballon Sizes of catheter : 4mm-20mm. Catheter Size 6Fr) Radiopaque for visibility under fluoroscopy. Long shelf life for sterility. ,Constructed of peelable material for introduction and passage through vessels that may be difficult to navigat, Colour coding for catheter size identification,Smooth tapered tip facilitating intro-ducting Each 15 ENDOBRONCHIAL TUBE 28FR LEFT,ENDOBRONCHIAL TUBE 28FR RIGHT,ENDOBRONCHIAL TUBE 30FR LEFT, Each 15 15 ENDOBRONCHIAL TUBE 30FR RIGHT,ENDOBRONCHIAL TUBE 32FR LEFT,ENDOBRONCHIAL TUBE 32FR RIGHT,ENDOBRONCHIAL TUBE 35FR LEFT,ENDOBRONCHIAL TUBE 35FR RIGHT,ENDOBRONCHIAL TUBE 37FR LEFT,ENDOBRONCHIAL TUBE 37FR RIGHT,ENDOBRONCHIAL TUBE 39FR LEFT,ENDOBRONCHIAL TUBE 39FR RIGHT, Endobronchial tubes to meet the demanding needs of the clinician. Ensures that the needs of smaller patients are met while providing a softer, straighter tube with a simple cap design, Should be available in both left and right orientations.,Extension tubes and pilot balloons are imprinted with Tracheal (clear) or Bronchial (blue) to differentiate the appropriate lumen and cuff. 16 EPTFE VASCULAR PATCH 0.4MM Made from a microporous sheet material that offers greater suture retention strength while allowing for host tissue incorporation,Special microporous biomaterial features solid nodes and thin fibrils of expanded polytetrafluoroethylene (ePTFE) to minimize foreign body response,Pre -configured patches require little or no trimming before implantation but they can easily be cut and shaped to size without fraying,Synthetic patch materials for successful in surgery for the repair of septal defects and for patch grafting. Each 17 EPTFE CARDIO PATCH 0.4MM Made from a microporous sheet material that offers greater suture retention strength while allowing for host tissue incorporation,Special microporous biomaterial features solid nodes and thin fibrils of expanded polytetrafluoroethylene (ePTFE) to minimize foreign body response,Pre -configured patches require little or no trimming before implantation but they can easily be cut and shaped to size without fraying,Synthetic patch materials for successful in surgery for the repair of septal defects and for patch grafting. Each 18 EPTFE CARDIO. PATCH 0.6MMMade from a microporous sheet material that offers greater suture retention strength while allowing for host tissue incorporation,Special microporous biomaterial features solid nodes and thin fibrils of expanded polytetrafluoroethylene (ePTFE) to minimize foreign body response,Pre -configured patches require little or no trimming before implantation but they can easily be cut and shaped to size without fraying,Synthetic patch materials for successful in surgery for the repair of septal defects and for patch grafting. 19 PTFE FELT (4X4) inch Each 20 SAUVAGE PATCH (4X4) Filamentous Knitted Polyester Fabric,Dimension 10.2 cm x 10.2 cm, double veloure dacron patch Each 21 INTER CORONARY SHUNT 1.00MM, 1.25MM, 1.50MM, 1.75MM,2.00MM, 2.25MM, 2.50MM, 2.75MM,3.0MM Disposable Coronary Shunt is used in off pump Coronary Artery Bypass Grafting operation,to Insure that there would be enough blood flow to the distant part of the heart,Disposable Coronary Shunt is made up of sillicon Tube(1),Sprin(2),connecting lin(3) and a piece of button for fixation(4) tip should be pointed tipe which helps to easy application (5) Transparent body. Each 22 MISTER BLOWER Advanced fluid/gas mixing technology for controlled delivery of CO2 and saline during off -pump surgery,Consistent & predictable blood clearing mist,Improved visibility at anastomosis and surgical site,Class VI implant tested tubing, DEHP Fre Only blower cannula without tubing and set available Each 23 MEASURED VOLUME SET Super smooth kink resistance tubing to ensure uniform flow rate.,Flexible, Transparent & soft cylindrical measured volume chamber with sharp and easy piercing Spike.,Smooth Roller Clamp to Facilitate easy, safe control and adjustment of fluid rates,Sterile / Each 17 17 Disposable / Individually Packe 24 A. Adult Oxygenator : 1. Priming volume should not be more than 185ml. 2. Blood flow range should be 0.5 to 6 ltrs./min. 3. Oxygenator should be coated with PH.I.S.I.O. Coating. 4. Membrane type should be Polypropelene. 5. 1/4 Suction Connection to Reservoir should have Minimum four numbers. 5. Venous Inlet of Reservoir Should have 360 rotation & Luer 1/2 x 3/8 Connector facilities. 7. Recirculation line Should have One Way Valve. 8. Cardiopledgia Port Should have Spring Valve Connection. 9. Carbon -di -oxide escape Port of Oxygenator must be With Side Luer Port to measure Carbon -di -oxide Preassure. 10. Reservoirs Blood Level Marking Should have up to minimum 20ml. 11. Dynamic operating volume should not be more than 420ml. 12. Heat exchanger surface should not be less than 0.40 m². 13. Membrane Surface area should be more than 1.38 m². 14. Heat exchange should be made by polyeurethane . 15. Blood storage capacity of hard shell reservoir should be approx 4500ml. 16. Minimum operating volume of reservoir should be 150ml. 17. Reservoir and oxygenator module should have rotatable connection. 18. Venous reservoir filter should be more than 40 µm polyster outer screen & 120µm inner polyster net. 19. Hard shell reservoir should have cardiotomy filter and de -foaming part. 20. Supplier should have proper authorization system complies with EN - ISO -13485:2012/AC -2012. 21. Supplier should provide with compatible stand. 22. Supplier should provide Certificate of Ethical collaboration in healthcare licensed by Eucomed . 23. Oxygenator can be used in both semi Each 18 18 adult and adult patients. 24. Venous inlet of the reservoir should be top of the reservoir. 25. Water inlet outlet port should be attached with the oxygenator module not the reservoir. 25 B. Paediatric Oxygenator : 1. Priming volume should not be more than 88ml. 2. Blood flow range should be 0.1 to 2.5 ltrs./min. 3. Oxygenator should be coated with PH.I.S.I.O. Coating. 4. Membrane type should be Polypropelene. 5. Venous Inlet of Reservoir Should be connected top end of Reservoir. 6. Heat exchanger surface should not be less than 0.05 m². 7. Membrane Surface area should be more than 0.60 m². 8. Heat exchange should be made by polyeurethane. 9. Blood storage capacity of hard shell reservoir should be approx 1500ml. 10. Minimum operating volume of reservoir should be 30ml. 11. Reservoir and oxygenator module should have rotatable connection. 12. Venous reservoir filter should be more than 40 µm. 13. Hard shell reservoir should have cardiotomy filter and de -foaming part. 14. Venous reservior inlet should have both 1/4 & 3/8 port. 15. Supplier should have proper authorization system complies with EN - ISO -13485:2012/AC -2012. 16. Supplier should provide with compatible stand. 17. Supplier should provide Certificate of Ethical collaboration in healthcare licensed by Eucomed . Each 26 B. Neonatal Oxygenator : 1. Priming volume should not be more than 35ml. 2. Blood flow range should be 0.1 to 1.5L/min. 3. Oxygenator should be coated with PH.I.S.I.O. Coating. 4. Membrane type should be Polypropelene. Each 19 19 5. Venous Inlet of Reservoir Should be connected top end of Reservoir. 6. Heat exchanger surface should not be less than 0.03 m². 7. Membrane Surface area should be more than 0.20 m². 8. Heat exchange should be made by polyeurethane. 9. Blood storage capacity of hard shell reservoir should be approx 500ml. 10. Minimum operating volume of reservoir should be 10ml. 11. Reservoir and oxygenator module should have rotatable connection. 12. Venous reservoir filter should be more than 40 µm. 13. Oxygenator inlet and outlet connection should have 3/16 connection site. 14. Hard shell reservoir should have cardiotomy filter and de -foaming part. 15. Supplier should have proper authorization system complies with EN - ISO -13485:2012/AC -2012. 16. Supplier should provide with compatible stand. 17. Supplier should provide Certificate of Ethical collaboration in healthcare licensed by Eucomed . 27 2.A Custom tubing pack Adult with arterial filter : 1. Class VI implant tested tubing. 2. Non -kinking, transparent, clear tubing, 3. Option of clear or colour stripes red/blue/green/yellow. 4. Pump head should be silicon made. 5. It should be bio compatible. 6. Arterial filter should be attached with the AV Loop of custom pack. 7. Arterial filter should be PH.I.S.I.O. Coating. 8. Arterial filter pore size should be 40µm. 9. Arterial Filter inlet & outlet port should be 3/8. 10. Maximum Blood flow should be upto 7 LPM. 11. Supplier should provide with arterial filter compatible stand. Each 28 B. Custom tubing pack Paediatric with Arterial filter etc

Key Value

Document Fees
INR 1000 /-
EMD
INR 100000.0 /-
Tender Value
Refer document

Attachment

FileName File Description File Size
Click here to download tender document Tender Notice 0 KB
Click here to download tender document Tender Document 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail