}

Tender For Making Illumination Arrangement And Mise Works At Aug. Of Sheherabazar Water Supply Scheme Raina-I Block Under Central Mechanical Division P.H.E. Dte. Purba-Bardhaman. Sl. No. Item Description 1 Supply & Delivery Of Following Materials At, purba-West Bengal

Government Departments has published Tender For Making Illumination Arrangement And Mise Works At Aug. Of Sheherabazar Water Supply Scheme Raina-I Block Under Central Mechanical Division P.H.E. Dte. Purba-Bardhaman. Sl. No. Item Description 1 Supply & Delivery Of Following Materials At. Submission Date for this Tender is 29-08-2024. Prime Mover Tenders in purba West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

44770043
Tender For Making Illumination Arrangement And Mise Works At Aug. Of Sheherabazar Water Supply Scheme Raina-I Block Under Central Mechanical Division P.H.E. Dte. Purba-Bardhaman. Sl. No. Item Description 1 Supply & Delivery Of Following Materials At
Open Tender
Indian
West Bengal
Purba
29-08-2024

Tender Details

tender for Making illumination arrangement and mise works at Aug. of Sheherabazar water supply scheme RAINA-I BLOCK under Central Mechanical Division P.H.E. Dte. Purba-Bardhaman. Sl. No. Item Description 1 Supply & delivery of following materials at below mention sites :- 2 GRP street light pole in conical shape using thermoset resign having minimum 65% glass content with following specifications :Length – 7 mtr.Top I.D – 85 + 2 mm.Bottom I.D – 176 + 2 mm. Thikness – 5 + 0.5 mm. Type – Non buried (above ground)The above pole is provided with suitable size MS base plate, foundation bolt & nut set, internal junction box & MS ring arm[Make -Fibro Plastichem / EPP/ PHE approved](Test certificate will be submitted at the time of delivery) [Installation will be done based on the site condition] 3 16 sq. mm 2 core 1.1 KV grade XLPE insulated Al. armoured Cable conforming to IS:7098 (Part-I) 2011 with upto date amendments. [Make- Gloster/ Mescab/ Currency/ Crystal/ Polycab/ PHED approved Make] 4 100W LED flood light luminarie with IP 65 protection.[Make: Philips (Type- BVP)/ Havells/ PHED approved make] 5 40W LED Decorative Post top for 3600light with IP 65 protection for gate light. [Make: Havells (Type- RUBYPT40W) / Philips/ PHED approved make] 6 GRP street light pole foundation work : 7 Making RCC foundation (as per drawing & measurement provided by GRP Pole manufacturer) for pole erection by using suitable reinforcement & concrete grade M20 inlcuding making provision looping cable line, excavation & refilling of earth pit with shifted soil & ramming properly as per specification & direction of EIC . 8 Al. ar. Cable laying work : 9 Laying of one no 16 sq.mm. PVC Al. Ar. cable in underground trenche 460mm. wide X 760mm. average depth, with brick protection on the top of the cable with 8 (eight) nos. bricks per mtr, including filling the space between the brick & cable & also the trench with shifted soil, levelling up & restoring surface duly rammed. 10 Laying 16 sq.mm. PVC Al. Ar. Cable through pump house wall including supply of sockets for clamping and grouting the above cable in each pole foundation (Approx 10 mtr length) 11 Supply & delivery of outdoor type Kiosk box (Size: 10x 6x12) with suitable gauge M.S. sheet along with hinged type front door with locking arrangement including M.S leg angle frame covered consisting 3 way Aluminium busbar 63 amp. fixed on a Porcelain material and grouting its legs in rick piller. 12 Installation of above supply Kiosk bok (item no.-3, c) and making brick/PCC foundation (Size: 14x 10x 18) with supplying bricks/stonechips, sand, cement etc including plastering and neat cement & making electrical connection complete as per direction EIC 13 LED set fitting & electic connection work : 14 Supply & drawing of 2 X 2.5 sq. mm and1 x 1.5 sq. mm (for earthing) FR PVC insulated 1.1 KV grade single core copper cable (PHED. approved make) from pole junction box to LED fixture at the top of the pole and making electrical connection complete 15 Erection of GRP pole on RCC foundation with help of MS base plate, foundation bolts, nuts, washers etc. and fitting & fixing of four (4) nos. flood light luminaris on pole ring arm with necessary inter connection and jointing of cable and testing complete of entire set as per direction EIC 16 Supplying and fixing GI/PVC water proof type looping cable boxof required size comprising with one 250 volt, 15amp kit kat fuse unit, one NL on porcelain insulator with locking arrngement fitted on brick wall with proper clamping arrangement for gate light 17 Fixing outdoor type gate light fitting on gate with supply upto 50 mm dia GI pipe as required length and making electrical connection by Al. armoured cable from loop box to light fiting (without controlling switch) laying over CC foundation including clamping & other necessary materials required to complete electrical connection. 18 Earthing of Loop Box by spike earhing (20mm X 2 mtr.) with drawing 8 SWG GI wire as per IE rule. 19 Supply & fitting G.I angle with wire net fencing arrangement for Gate light 20 Supply & fitting fixing 16 Amp. SPN MCB (Make-Havells/ Siemens/ ABB/L&T) with enclosure & 16 Amp Piano key type Switch with pvc boxinside the pump house wall and making connectin with supply cable for operating the compund light with supply necessary materials all complete as per direction of EIC. 21 INSTALLATION OF VOLTAGE STABILIZER 22 Supply and delivery at site the following items:(Approve make of P.H.E Dte.) 23 Supply and delivery at site A.C. 3 ph.Oil cooled type Voltage Stabilizer suitable for unbalanced input voltage (Make: AE/Sen & Pandit / Opto Elec. / ECS/Fizi/other Approved Make)a) Input:250-500 V 3ph. 50HZ, 4 wireb) Output, 415V + 1% 3ph.,50HZ.c) Capacity: 25KVA.d) Auto manual switch IS - 9815 (I). e) Raise/lower push Button.f) Single lamps to indicate and limits of input.g) Voltmeter for input and output Voltage. (Manufacturing test certificate should be produced at the time of delivery)h) With U/V.O./V.O./L protection with contractor at output side, input MCB & Ammeter etc. ( TC /GC Needed ) [Installation will be done based on requirement and suitability of the site condition] 24 Change over switch 100 Amps 415V, 50 Hz, 4pole onload.Make: Havells/ standard/Approve make of P.H.E. Dte.) 25 100 Amp. Re-wireable type TPN main switch (CONFORMS: IS/IEC600947-1&3). (Make: Approve make of P.H.E. Dte.) 26 100 Amp. 4 way Copper busbar chamber box by 16 SWG sheet steel enclosure including porcelain chair etc.. (Make: Approve make of P.H.E. Dte.) 27 25 sq.mm 3.5 core 1.1KV PVC/XLPE insulated aluminium armored cable.(Make: Approve make of P.H.E. Dte.) 28 Making brick built foundation with supplying of all required materials suitable for the above Voltage stabilizer by (4:1) cement mortar including holding down foundation bolts (if req.) & plaster with neat cement finish as direction of E.I.C. 29 Installation of the above stabilizer on the foundation including all connection complete,drawing the cable properly on GI cable tray on wall /as per direction of EICalong with supplying all necessary item including testing complete. 30 Making joints of the cable by supplying compression type gland thimple,socket etc.as per requirement and as per direction of EIC. 31 AT NEWLY BUILT PUMP HOUSE SHYAMSUNDAR P.H-1 32 Supply, delivery at site and storage wall mounted made of sheet steel fabricated 2 mm for load bearing & 1.6mm for non load bearing, indoor type, dust & vermin proof, lP-54 degree of protection,powder coated painted with rubber gaskets cover, front lockable hinged door with all ,Switchgear and other items duly wired up and tested as per specification.: Incomer: (A) 100 Amps, TPN MCCB with adjustable OL, 36 KA, necessary accessories with suitable SPD (i.e., Ammeter, Voltmeter, CTS,UV/OV protection & Switches), (B) Outgoing:- 15- 25 HP, TP Star-delta Starter withother accessories - 1 Nos., (Suitable size capacitor bank to improve PF from o.85 to 0.98) (C) 0.5 HP ,3 PH,415V,Clorinator feederwith necessary accessories & level controller-1 no(D) Yard lighting feeder with necessary accessories & time switch - 1 No. (E) Automatic operation feeder with PLC operated .( Panel make ,All spare & components as per vendor list of phed). 33 Installation of above MCC panel along with main switch, change over etc all electrical equipment with in the pump house, drawing the cable properly on wall as per direction of EIC as per layout and IE rules and all connection with supply necessary materials, cable etc to complete the work, making arrangement with supply & fitting of materials for taking power with in the pump house from WBSEDCL end as per direction of EIC. 34 Supply, delivery and storage at siteof automatically controlled diaphragm type chlorinator dosing pump with flow rate 100 LPH and maximum pressure of 10Kg/CM2 with all accessories for pump & motor, foundation bolt, suction and discharge Flange and with storage tank of dosing solution of 100Ltr. Capacity and the prime mover to be coupled with pump of 0.5 H.P. 3 Phase, 1450 RPM squirrel cage TEFC induciton motor, Motor will be IE2/IE3 (Make of Machine : Swelore/Any other approved, Make of Motor : ABB / CGL /KEC / Any other approved make) 35 Installtion and commissioning of above supplied chlorinator with all accessories, PVC tank and drawing of power line as per IE rules by supplying of necessary wire and continuous earthing. This include the cost of all necessary CC foundation [at least 200mm height] with concrete mixture [sand, cement, stone chips] and neat cement finish by supplyig of all required materials and testing the entire set as per direction of EIC [power will be feed from PLC Panel of pumping machinery] 36 Distribution wiring in 1.1KV. Grade, (2X1.5mm2) single core stranded FR PVC insulated & unsheathed copper wire (approved make) in suitable size PVC casing capping (Precision make) with (1.5 Sqmm) single core stranded FR PVC insulted & unsheathed copper wire for ECC, including necessary PVC clips, fittings etc. to light/fan point with piano key type switch (anchor make) fixed on pvc/sheet steel fabricated switch board with Perspex/bakelite top cover on wall including necessary connections and making earthing attachment and mending good damages to building works. [PVC casing-capping and Switch board both on surface] 37 a) average run 4. 5 mtr. - 38 Supply, delivery and storage at site Full Bore Electromagnetic Flowmeter DN 200,Protection IP 68 (Minimum inbuild 20 meter cable,factory potted) ,Full bore type Electro Magnetic Flow meter with smart Transmitter (Volume Flow rate output : 4-20mA HART Output and totalizer pulse output:0.05 cum/Pulse) with LCD 4 line backlit display ,calibration lab as per ISO 17025,Accuracy .5% +/- 2mm/sec,measuring,reference & empty pipe detection electrode with Polyurethane/Hard rubber liner,supply: 24 v DC or 230VAC. [Make- Endress+ Hauser(India) Pvt.Ltd/ Approved Make] 39 Magnetic Flow Meter DN80 40 Magnetic Flow Meter DN200 41 Installation of above mentioned full bore electromagnetic flowmeter (DN80) with laying of cable (DEPT.SUPPLY) and suppling of other fixing material all complete as per direction of EIC. 42 Installation of above mentioned full bore electromagnetic flowmeter (DN200) with laying of cable (DEPT. SUPPLY) and suppling of other fixing material all complete as per direction of EIC. 43 Add. GST@18% 44 Add. Cess@1%

Key Value

Document Fees
Refer document
EMD
INR 36300.0 /-
Tender Value
INR 17.58 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail