}

Re E-Tender For Procurement Of Consumable Items For Two Years From The Date Of Award Of Contract (Aoc), kolkata-West Bengal

Government Departments has published Re E-Tender For Procurement Of Consumable Items For Two Years From The Date Of Award Of Contract (Aoc). Submission Date for this Tender is 17-09-2024. Cosmetics Tenders in kolkata West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

44768680
Corrigendum : Re E-Tender For Procurement Of Consumable Items For Two Years From The Date Of Award Of Contract (Aoc)
Open Tender
Indian
West Bengal
Kolkata
17-09-2024

Tender Documents

Tender Details

RE E-TENDER FOR PROCUREMENT OF CONSUMABLE ITEMS FOR TWO YEARS FROM THE DATE OF AWARD OF CONTRACT (AOC)- 1 A thermal shield for a newborn infant, a double layer of PE/PUR wrapping Simple tool of pre-formed foam which acts as a barrier against heat loss for heat loss prevention or hypothermia, applicable for use in all settings where birth may take place Impaired heat production in preterm and ill newborn infants lose heat by conduction, evaporation, convection and radiation. Sizes are available according to the corpulence of the baby: Small, Medium and Large. 2 AC Lens • Material: PMMA • Optic Size: 6.00 mm • Overall Langth: 12.75 mm • A-Constant: 114.9 3 Accessories of Nerve Stimulator N.S Needles with continuous plexus and peripheral nerve blocks (compatible with approved machine) - Metalic Stylet allowing stimulation - Perineural Polyurethane Catheter 25mm, 35mm, 50mm, 100mm - 10X15 adhesive transparent dressing 4 Accessories of Nerve Stimulator(to use in o.t)Cerebral Stimulator –Nerve Stimulator – Cable Wire 5 Accessories of Nerve Stimulator(to use in o.t)Cerebral Stimulator –Nerve Stimulator – N.S Needle 6 ACCESSORIES OF USG - GEL HYPOALLERGIC 250 ML CONTAINER WITH NOZZLE 7 ACT tube for ACT management for CPB 8 Aortic Punch Precisely engineered scissor cut blade. Single use Aorta/vein punch provided clean accurate incisions for miocardial revascularization. Large finger ring for greater control and accuracy. Easyly cuts through thick calcified tissue. 9 Basic Set – Procedure pack contains essential items needed for a number of common procedures including Lumber Puncture, Spinal Anaesthesia, Epidural Anaethesia, Liver Biopsy, Paediatric Surgery, Oncology etc. (also offers custom made service) i. Tray ii. Syringe Luerslip iii. Aperture Drape iv. Galipot v. Prep Forceps vi. 4 Ball Swab (small) vii. 2 Ball Swab (large) viii. 1 Filter Needles 5 um ix. 3 Hypodermic Needles 18G, 21G & 25G x. 1 Outer Wrap 75 X 70 cm xi. Absorbent Towel 33 X 38 cm 10 Bioprosthetic Heart Valve for Mitral / Aortic Position * Triple Composite Design Valve. * Sewing ring is made of Polyester with markers for helping in sutures. * Low pressure glutaraldehyde fixation. * Flexfit stent of reduce leaflet stress. * Mitral Retchating system failitates insertion into mitral annules and avoids suture looping. * Low Profile hieght of 9 mm. * Intra & Supra Annulur implatability * No + 1 Regurgitation * Sizes Mitral : 25mm to 33mm Sizes Aortic : 19mm to 25mm 11 Blood Cardioplegia Device - Paediatric – Heat exchanger pleatal type. Priming volume of heat exchanger : <30 ml . Integrated heat exchanger with bubble trap. Assemble with Class VI Implant tested tubing. High cooling eficiency. Eassy set up and priming. Outlet comnnection 1/4 built in bridge for choice of 100 % blood and 100 % cardiopledgia solution delivery. Extra 1/4 tube and 1/4 x 1/4 luer lock connector, 2 length of tube. 12 Bone Graft Substitutes with Antibiotics 1. BONE SUBSTITUTE HYDROXYAPATITE GRANULE / BLOCKS MATERIALS. 2. ANTIBIOTICS MAY BE MIX WITH HYDROXYAPATITE SEPARATLY 13 Bridge Dressing for bridging the wound where the wound location is not suitable for dressing for VAC Unit 14 Bubble Trap (Adult) : Polycarbonate,Polyester, Filter Port - 170um, Blood port - 3/8 (9.5mm) , Vent port - female luer , Priming Volume - 150ml, Max.Blood Flow 6.5L/min. 15 Bubble Trap (Paediatric) : Polycarbonate,Polyester, Filter Port - 170um, Blood port - 1/4 (6.4mm) , Vent port - female luer , Priming Volume - 50ml, Max.Blood Flow 1.6L/min. 16 CDC Guided Peripheral IV Securement Device with component: 1 No 2% Chlorohexidine Gluconate & 70% Isopropyl Alcohol wipe as per CDC recommendations, 1 No Sterile Gauze piece,1 No Latex Free Synthetic Poly-isoprene Based texture Surface Material Of Tourniquet,1 No Transparent Semi Permeable polyurethane film with Reinforcement of Waterproof Soft cloth and Pattern Coated Adhesive for Higher Sweat Transfer Rates Dressing. Size - 7 cm X 8.5 cm - 9 cm. 17 Cuff Manometer (Cuff Inflator Pressure Gauge): 1. Allows controlled initial cuff inflation. 2. Intermittend pressure monitoring facility. 3. Instant visual confirmation of intra-cuff pressure. 4. Simple operation of pressure adjustment without need for disconnection or introduction of syringe into system. 5. Solid green zone indicates ususal cuff pressure range for tracheal & tracheostomy tubes. 6. Connecting tube is supplied with the gauge for convenient positioning. 7. Portable gauge and clips easily into pock. 18 Custom Pack for Membrane Oxygenator (Neonatal) - Class VI implanted tubing. Non-kinking transparent clear tubing. Should be Clear and Colour strip. Component include Gas line filter. Pre by pass filter. 19 Custom Pack for Membrane Oxygenator (Paediatric) - Class VI implanted tubing. Non-kinking transparent clear tubing. Should be Clear and Colour strip. Component include Gas line filter. Pre by pass filter. 20 CVC 9.5 Fr., Silver Ion Impregnated Thermosensitive Polyurethane Penta Lumen Adult CVC with Anti Kinking Nitinol Guide Wire. Size - 14 G / 16 G/ 18 G/ 18 G/ 18 G 21 CVC Catheter Fixation Device - (Epidural, CVC, Arterial) * Infection Free Painless Suture Less Catheter Fixation Device. 22 CVC Pediatric set Oximetry Catheter of size - 5.5 Fr. Having optical cable to monitor SCVO2 with CCO Monitor for Neonatal and Pediatric Patients. 23 Dark Goggles (Adult size) with side covering 24 Dark Goggles (Paediatric size) with side covering 25 Diathermy Pad Foam and woven backing material Bipolar model. Upright and horizontal shape. The patent shape outline design make the adhearence to be more close and comfortable on body joint anf lift bones. The conductive gel covers over the edge of metal foil. It can avoid the burned hurt which because by the connection of metal foil and skin. 26 Disposable Fluid warmer Tubing, * Blood and IV Fluid warmer set with Injection port. 27 Disposable Neonatal Blood Exchange Set with Accessories 28 DISPOSABLE SUCTION POD STABILISATION SYSTEM FOR CABG, THE POD SHOULD ROTATE 3600 29 Ear Speculas Specification : a. Troeltschs ear specula, adult size, set of 3. b. Troeltschs ear specula, infant size, set of 3. 30 Epidural anaesthesia kit containing 18G/16G Touhy needle (80-100 mm length, graduated at 10 mm intervals, snap lock wing), LOR syringe-10 ml, Epidural catheter-clear nylon/ polyurethane/ polyamide material, closed round soft tip with multiple lateral eyes within 4 mm of tip, length 90-100 cm, Radiopaque line, size as per needle gauze (Latex, PVC & DEHP free), Threading Assist Guide provided to fit securely into the needle & assist easy advancement of catheter, luer lock connector, Easy fixation device with 0.2-micron filter. 31 Epidural anaesthesia kit containing 18G/16G Touhy needle (80-100 mm length, graduated at 10 mm intervals, snap lock wing), LOR syringe-10 ml, Epidural catheter-clear nylon/ polyurethane/ polyamide material, closed round soft tip with multiple lateral eyes within 4 mm of tip, length 90-100 cm, Radiopaque line, size as per needle gauze (Latex, PVC & DEHP free), Threading Assist Guide provided to fit securely into the needle & assist easy advancement of catheter, luer lock connector, Easy fixation device with 0.2-micron filter. 32 ET tube holder with bite blocker 33 Eye Pad With Out Adhesive. • Gauze or nonwoven covered outside, cotton inside. • Size: Standard size in Oval Shape to cover the eye. • Individual pack in sterile packaging, ETO (EO) Sterile Eye Pad. • Without Adhesive. 34 Femoral Arterial - 15F to 22F (Straight) 35 Femoral Venous - 17F, 19F, 21F & 23F 36 Foldable Lens (Phaco) • Single piece Foldable Lens • Material is UV Block incorporated ensuring adequate UV protection • Optics are YAG Laser friendly • Non-lonic nature of materials ensures resistance to deposits thus lowering the incidence of PCO • Material: Acrylic Hydrophilic • Optic Type: Biconvex • A-Constant: 118.0 • Optic Size: 6.0 mm • Overall Langth: 12.5 mm 37 Foldable Lens (Phaco) of different IOL powers: + 1 D to + 25 D • Single piece Foldable Lens • Material is UV Block incorporated ensuring adequate UV protection • Optics are YAG Laser friendly • Non-lonic nature of materials ensures resistance to deposits thus lowering the incidence of PCO • Material: Acrylic Hydrophobic • Optic Type: Biconvex • A-Constant: 118.0 / 118.5 • Optic Size: 5.5 mm / 6.0 mm • Overall Langth: 12.5 mm 38 Head Lights Specification : a. Combination of xenon bulb and LED bulbs. b. 18 lumens, xenon: 7.5 lumens, LED. c. 90 degree tilting head. d. Water resistant. e. Push button switch. f. Unbreakable poly carbonate lens. g. Weights less than 5 Oz with batteries. h. Runs on alkaline batteries. 39 INSTRUMENT TRAY E. I. 30 C. M. X 25 C. M. WITH COVER STAINLESS STEEL IS 3257, IS 3424 40 Intra abdominal pressure monitoring kit 1. Intra abdominal pressure monitoring kit with transducer compatible 2. with present interface cable or without transducer with sleeved syringe. 41 Intubating stylate – small, malleable, aluminium tubating stylets. Each stylet is enclosed in a PVC sheath having blunt ends to reduce the risk of trauma . 42 Intubating stylet – large, malleable, aluminium tubating stylets. Each stylet is enclosed in a PVC sheath having blunt ends to reduce the risk of trauma . 43 Intubating stylet – medium, malleable, aluminium tubating stylets. Each stylet is enclosed in a PVC sheath having blunt ends to reduce the risk of trauma . 44 Jobson Horne Probes Specification : a. Double ended – Serrated tip & smooth ring, length 140 mm. b. Made up of good quality rust free stainless steel materials. 45 Measuring Tape (MUAC) 46 Measuring Tape (WC) 47 Mono leaflet Mechanical Prosthetic Mitral / Aortic Valve with elevated pivot guards • Mono leaflet Rotatable or Tilting disc Rotatable • Swing Ring Hence-25 alloy • Disc made of UHMPE • Swing Ring made of Polyester 48 Mouth Gag 49 Moving Front Chemical Indicators To Verify All Parameters Of Steam Sterilisation To Gather i.e. Time, Temperature & Equality Of Steam Read Out Indications After Accept Or Reject Process & Allows To Differentiate All The Parameters 50 MOX (Connector) with pressure gauge 51 MOX-26 OXYGEN PRESSURE REDUCING VALVE 52 Multiple Clip Applicator - Should be 20 titanium clips of different sizes with precise angled jaws. Anti drop rachet. Latteral Transverse inner grooves. 53 NEONATAL/INFANT RESUSCITATOR SET COMPLETE IN A CARRYING CASE (FOR LABOUR ROOM, MOBILE VANS AND PAEDIATRIC WARDS & O.T.S) 1. Silicone Manual Resuscitators Autoclavable Reusable, Non- Rcbreathing valve, 360 degree swiveling patient connector, Autoclavable Oxygen Reservoir. 1.5 mtr. Oxygen tubing. 2. Should have two silicone manual resuscitator for Neonate of 200ml. to 250m1. and for Infant of 550 ml to 650ml with size of 0, l, 2 & 3 face masks. Silicone manual resuscitator. 3.Should be supplied with carrying cum storage bag 54 Non-invasive Skin Closure Strips With Sterile Breathable Non- Oven Rayon Backed Miroporous Material With Filaments For High Tensile Strength, Containing Hypoallergenic Adhesive To Reduce Skin Trauma & Scars Chances Of Infection Leading To Optimum Cosmetic Outcomes. Size - ¼” X 3”/6 mm X 75 mm 55 Non-invasive Skin Closure Strips With Sterile Breathable Non- Oven Rayon Backed Miroporous Material With Filaments For High Tensile Strength, Containing Hypoallergenic Adhesive To Reduce Skin Trauma & Scars Chances Of Infection Leading To Optimum Cosmetic Outcomes. Size - ¼” X 1½”/6 mm X 38 mm 56 Non-invasive Skin Closure Strips With Sterile Breathable Non- Oven Rayon Backed Miroporous Material With Filaments For High Tensile Strength, Containing Hypoallergenic Adhesive To Reduce Skin Trauma & Scars Chances Of Infection Leading To Optimum Cosmetic Outcomes. Size - ¼” X 4”/6 mm X 100 mm 57 Non-invasive Skin Closure Strips With Sterile Breathable Non- Oven Rayon Backed Miroporous Material With Filaments For High Tensile Strength, Containing Hypoallergenic Adhesive To Reduce Skin Trauma & Scars Chances Of Infection Leading To Optimum Cosmetic Outcomes. Size - ½” X 4”/12 mm X100 mm 58 O2 Recovery Kit for tracostomy with separet valves and star lumen crush technology o2 tube 59 Otoscope Specification : a. All Plastic Moulded Head. b. 2.5v Halogen Bulb. c. Acrylic viewing window built into instrument. d. Swiveling viewing window built into instrument. e. Four (4) Reusable Specula of the diferent sizes. 60 Oximetry CVC Catheter 16/20 CM for ScvO2 Monitoring (Disposable single Use) 61 OXYGEN CYLINDER - FINE ADJUSTMENT VALVE ONLY 62 OXYGEN CYLINDER FLOW METER (FINE ADJUSTMENT VALVE AND GAUGE) 63 OXYGEN CYLINDER KEY FOR VALVE BULL NOSE TYPE 64 P. V. C TUBING 3/4 X 10 MTR STERILE 65 PACING WIRE SUTURE (Atrium / Ventricle) 66 Paediatric Cuff endotrachealTube, Size - 2.5, 3, 3.5,4, 4.5, 5.1. Internal and external diamiter should be mentioned.2. Material shoul be latex free PVC medical grade.3. Low Pressure high volume cuff.4. Printed pilot balloon.5. Smooth Murphy eye.6. Radio opaque line.7. Vocal cord guide mark.8. Misting can be clearly seen. 67 Pain relief detachable silicon implantable catheter 6.6Fr with Antikinking Sleeve sitimplant titanium device with Peel away desilet, compatible with MRI frequency-height (8mm-11mm) & weight (3.5g-10.5g) with tunnellisation needle and Teflon coating Nitinol Guide wire, Bloodless access & vein lifting device. 68 PC IOL (RIGID) • Material: PMMA • Optic Size: 6.0 mm • Overall Langth: 12.5 mm • Power: +2.00 to 35.000 (0.50 Steps) • A-Constant: 118.2 • Optical Clarity to ensure high contrast sensitivity. 69 Pediatric Shunt, Size - 3, 3.5, 4 & 5 mm, * Shunt should be made by PTFE. * Shunt length should be 10cm,* Shunt should be used in Cardiac Procedures. 70 Pediatrics Endotoxin (96 hours ) Filter with Triple Layer extension tube with Clamp, for Air Eliminating 0.22um, Priming volume: 0.8ml Flow rate : 7 ml/min. 71 Percutaneous Dilation Tracheostomy 7, 8, 9 mm 1. Should have scalpel with number 15 blade 2. Should have an introducer needle 3. Should have a 10ml syringe for aspiration 4. Should have 14Fr pre-dilator 5. Should have extra long guide wire 6. Should have a well marked extra length guiding catheter 7. Should have a hydrophilic graduated single stage dilator 8. Should have a cuffed sub-glottic tracheostomy tube 9. Should have a tracheostomy tube obturator 10. Should have a flexible inner cannula 11. Should have swabs for cleaning 12. Should have a tracheostomy tube holder 13. Should have FDA/CE approval 72 PIN INDEX VALVE FOR O2 AND N2O FOR ANAESTHETIC APPARATUS 73 Porcine Bioprosthetic Heart Valve • Both Aortic / Mitral Position. • Aortic Position – Sizes 19 to 29mm, • Mitral Position – sizes 25 to 33 mm.• It should have anticalcification treatment. • Profile height 9 mm-11 mm radioopaque marker for future valve in valve. 74 Positive Airway Pressure System : 1. 22mm OD patient end to accommodate mounthpiece. 2. Scalloped ambient air inlet with gaps to resist occlusion. 3. Pressure port with white sealing cap, to allow connection to a gauge for easy monitoring. 4. Gas inlet port to allow connection to O2 source with a flow meter. 5. Can be used in conjunction with aerosol medication (e.g nebulizer) via 22mm connection. 6. Available with a disposable manometer. 7. Transparent design for visual monitoring of contaminants. 75 Prosthetic Knitted Dacron Bifurcated Graft, Size: D - 14 x 7 mm, 16 x 8mm, 12 x 6mm, 18 x 9mm, 20 x 10mm L- 45cm, * Gelatin impregnated. 76 Prosthetic Knitted Dacron Graft, Size : D - 8 to 14 mm L - 60 cm, * Gelatin impregnated. 77 Prosthetic Knitted Dacron Graft, Size: D - 16 to 32 mm L - 20/25/30cm, * Gelatin impregnated. 78 PTFE (Compressed) Felt Pledgets Size - 9.5 x 4.8 mm * Thickness should be 1.65 mm, * Pledgets should be buttreness under suture of tearing through tissue. 79 PTFE membrance patch for reconstraction in congenital cardiac surgery 80 PTFE vascular graft of different sizes (5mm to 8mm) - Plain 81 PTFE vascular graft of different sizes (6mm to 8mm) – Ring Reinforce 82 Radial or Femoral Arterial Sensor /Finger Cuff (Disposable single Use) 83 Rechargeable Surgical Clipper With Fixed Head & Cutting Disposable Blade Run Time Of 160 Minutes, Rechargeable With Lithium Ion(Li-Ion) Battery With Drop In Charger With Or Without A Cord & Single Used 36.4mm Width Blade Snap On & Pop Off Easily 84 RETRACTOR, ABDOMINAL DOYENS SIZE 8 CM. 85 Reusable Arm for Vaccum Stabilization & Positioning system: - 360° articulation maximizes vessel access and stabilization. Universal swivel mounts on retractor to provide procedural versatility. Dynamic tissue adherence ensures superior stabilization on the beating heart. Advance vaccum stabilization & positioning minimizes tissue trauma. 86 Reusable Introducer : 1. Reusable Introducer to have a coude/angled tip to easily identify tracheal rings in difficult intubatiions. 2. Clear gratuaded markings to indicate intubation depth. 3. Size : 15CH, 60 cm 4. Should be Latex free. 87 REUSEABLE LARYNGEAL MASK AIRWAY, SIZES - 1, 1.5, 2, 2.5, 3 & 4 1. It should be anatomically curved/straight 2. It should be made of Silicon/PVc 3. It should be 100% sterilizeable 4. It should have colour coded pilot balloon to identify mask size 5. It should have depth marks for monitoring correct position 88 REUSEABLE PROSEAL LARYNGEAL MASK AIRWAY, SIZES - 2, 3 & 4 89 SF IOL • Material: Acrylic • Single / Multi piece • Optic Design: Equiconvex • Optic Size: 6.50 mm • Overall Length: 13.50 mm • Haptic Angle: Modified C • Dialling Holes: 2 Eyelets • A-Constant: 118.2 90 Silicon Aircufe Tracheostomy Tube - Size - 6mm/7mm/8mm 91 Silicone Cuffed Tracheostomy tube for Paediatric. Size - 2.5 mm / 3 mm / 3.5 mm / 4 mm / 4.5 mm / 5 mm / 5.5 mm 92 Single Ball Spirometer, single ball spiro with lower inspiration capicity from 200 cc - 1200 cc 93 Single Use Bougie 94 STERILIZING DRUMS, FOR USE IN STERILIZERS AND FOR STRONG STERILIZED DRESSINGS. IMPROVED PATTERN. MADE OF EXTRA HEAVY STEEL WITH DOME SHAPED TOP AND BOTTOM AND CHROME PLATED. ABSOLUTELY DUST PROOF. HASPS LOCK THE JACKET TIGHTLY IN ORDER 235 IN. DIAM. X 120.65 MM. HEIGHT [STERILIZER, SHALLOW (DRESSING DRUM)],IS3831 95 STERILIZING DRUMS, FOR USE IN STERILIZERS AND FOR STRONG STERILIZED DRESSINGS. IMPROVED PATTERN. MADE OF EXTRA HEAVY STEEL WITH DOME SHAPED TOP AND BOTTOM AND CHROME PLATED. ABSOLUTELY DUST PROOF. HASPS LOCK THE JACKET TIGHTLY IN ORDER 235 IN. DIAM. X 241 MM. HEIGHT [STERILIZER, SHALLOW (DRESSING DRUM)],IS3831 96 STERILIZING DRUMS, FOR USE IN STERILIZERS AND FOR STRONG STERILIZED DRESSINGS. IMPROVED PATTERN. MADE OF EXTRA HEAVY STEEL WITH DOME SHAPED TOP AND BOTTOM AND CHROME PLATED. ABSOLUTELY DUST PROOF. HASPS LOCK THE JACKET TIGHTLY IN ORDER 285.75 IN. DIAM. X 241 MM. HEIGHT [STERILIZER, SHALLOW (DRESSING DRUM)],IS3831 97 STERILIZING DRUMS, FOR USE IN STERILIZERS AND FOR STRONG STERILIZED DRESSINGS. IMPROVED PATTERN. MADE OF EXTRA HEAVY STEEL WITH DOME SHAPED TOP AND BOTTOM AND CHROME PLATED. ABSOLUTELY DUST PROOF. HASPS LOCK THE JACKET TIGHTLY IN ORDER 336.55 IN. DIAM. X 241 MM. HEIGHT,IS3831 98 STERILIZING DRUMS, FOR USE IN STERILIZERS AND FOR STRONG STERILIZED DRESSINGS. IMPROVED PATTERN. MADE OF EXTRA HEAVY STEEL WITH DOME SHAPED TOP AND BOTTOM AND CHROME PLATED. ABSOLUTELY DUST PROOF. HASPS LOCK THE JACKET TIGHTLY IN ORDER 381 IN. DIAM. X 279.4 MM. HEIGHT,IS3831 99 SUTURE MATERIAL, STERILISED CHROMIC CATGUT NO SIZE - 3 LENGTH MIN 152 CMS 100 Swivel Connector having 360 degree rotating connector for ET Tube 101 Synthetic fiberglass cast material - 4 102 Synthetic fiberglass cast material - 5 103 Tracheal Access device with Suction port. Size: 6, 6.5, 7, 7.5, 8, 8.5, 9 mm. 1. It should have a Low pressure-High volume / low pressure-low Volume Reverse cuff, whose inverted profile allows pooling and easy removal of secretion from the above the cuff while leaving the tube in-situ. 2. Low pressure high volume smooth tapered soft seal cuff made from velvet soft PVC material, for minimal risk of trauma. 104 Tracheostomy tube with suction port Sizes 6, 7, 7.5, 8, 8.5, 9, 10 mm. 1. Made of thermo-sensitive clear PVC that softens at body temperature to conform to patient anatomy. 2. Integral suction lumen allows removal of pooled secretions. 3. Clear suction line for removal of pooled secretions. 4. Profile Low Pressure-High Volume Soft Seal® with reduced bulk and smooth transition to tracheostomy tube to improve ease of insertion. 5. 15 mm connector located on the tube, not the inner cannula. 9. Smooth inner cannula (available separately). 10. Available in sizes ranging from Single-use. 11. Should have FDA/CE approval 105 Tricuspid Rigid Annuloplasty Ring - Assorted Sizes Rigid ring for durable repair Complete or Open Ring conforms s to Tricupsid annulus Marking for anatomic orientation, US-FDA / CE Approved. 106 Twin Flow Polyurathane Radiopaque Peripherally Inserted Central catheter with Neocath Split Introducer for Premature Babies & Neonates Medication & Nutrition. 107 Umbilical Artery & Venous catheter in fully radio-opaque polyurethane with a distal eye and lateral eye, rounded distal tip Actual distance from the distal tip is printed numerically from 4 to 20cm Proximal extension tubes(PUR) Length:5cm, with clamp Reduce the number of peripheral routes required subsequently Size: 2.5 Fr, 3.5 Fr, 4 Fr, 5 Fr, 8 Fr & Length: 30 - 40 cm. 108 Umbilical Tape Sterile prepackaged hypoallergenic nonwoven material 109 Uncuffed Fenestrated Tracheostomy Tube Kit . It should have multiple fenestrations . The Kit should also contain 2 inner cannulas (1 fenstrated &1 non fenestrated), cleaning brush, Strap and decannulation cap. 110 Uncuffed fenestrated Tracheostomy Tube Kit : 1. Should have uncuffed tracheostomy tube kit. 2. Should have 2 fenestrated inner cannulae that has a pull ring that aids which aids in smooth insertion and removal from tube, minimizing patient trauma. 3. Should have a cleaning brush to clean the tracheostomy tube and inner cannula. 4. Should have a tracheostomy tube holder. 111 Vascular loop, silicon, length 15-20 cm, assorted size 112 VIDEO LARYNGOSCOPE WITH DISPOSABLE BLADES, SIZE -1, 2, 3, 4. 1. Monitor size should be at least 2 2. It should be supplied with Channeled and Non-Channeled blade 3. Blade size should be 1,2 & 3 cm. or 2,3 &4 cm. (any three size) 113 Weighing Machine FOR Baby 114 Weighing Machine for Blood donors 115 Adhesive Elastic Bandage (10cm X 4 mtr.) 116 Advance vaccum stabilization: Stabilizer with ball attachment , suction 360 degree articulation maximizes vessel access and stabilization , Malleable footprint. 117 Angioplasty, Peripheral stent of different size- 4,4.5,5.• Catheter length 135cm.•Stent length should be 20,30,40,60,80,& 100 118 Bain Circuit : Jackson Rees modifications of Ayres T-Piece system with 15 & 10 ML corrugated tube with a 500 ML antistatic rebreathing Bag and a bag bleed valve. 119 Bulldog Clamp (Micro), Curved 3.5 cm lengths, Single use bulldog clamps are a lightweight radiopaque plastic construction. Colour coded according to clamp size and pressure. Atraumatic Jaw designs. Parallel clamp designed for maximum occlusion and atraumatic pressure. Latex-safe. 120 Bulldog Clamp (Micro), Curved 4 cm lengths, Single use bulldog clamps are a lightweight radiopaque plastic construction. Colour coded according to clamp size and pressure. Atraumatic Jaw designs. Parallel clamp designed for maximum occlusion and atraumatic pressure. Latex-safe. 121 Bulldog Clamp (Micro), straight 3.5 cm lengths, Single use bulldog clamps are a lightweight radiopaque plastic construction. Colour coded according to clamp size and pressure. Atraumatic Jaw designs. Parallel clamp designed for maximum occlusion and atraumatic pressure. Latex-safe. 122 Bulldog Clamp (Micro), straight 4 cm lengths, Single use bulldog clamps are a lightweight radiopaque plastic construction. Colour coded according to clamp size and pressure. Atraumatic Jaw designs. Parallel clamp designed for maximum occlusion and atraumatic pressure. Latex-safe. 123 CANNULA, AORTIC ARCH CANNULA WITH METAL LEGS, 124 CANNULA, DISPOSABLE THORACIC DRAINAGE WITH TROCAR 125 CATHETER, AORTIC BALLOON VALVOPLASTY CATHETER 126 CATHETER, PULMONARY BALLOON ANGIOPLASTY CATHETER 127 Central Venous Catheter : 24G Radiopaque polyurethane peripherally inserted central venous catheter for premature neonates weighing <1KG 128 Central Venous Catheter : 28G Radiopaque polyurethane peripherally inserted central venous catheter for premature neonates weighing <1KG 129 Circular Stapler for End to End Anastomosis With different staple height. Size : 24/25/28/29/31/33/34 mm various type of tissue thickness starting from 1.00 mm to 2.5mm. Open staple leg length should be approx 3.0 to 5.5 mm. Non slip gripping surface. Assorted Sizes.should have 2 rows/3 rows 130 CLIPS, TOWEL HOLDING, CROSS ACTION IS 4066:1967 131 Convective Warmer System, N.B.:*Should deliver warm air uniformly to the patient through disposable plastic blankets.* Should have 4 set temperatures: Ambient, 36 OC, 40 OC, 44 OC.* Should have hose end temperature control system.*Hose must have four rectangular openings at the end to allow air flow in case blanket is causing occlusion. * Should have short warm up time.*Should be quiet and light weight.*Can be mounted to the infusion pole or bed rails or placed on the floor.*Should display actual temperature of air being delivered to the patient.* Must meet all convective warming standards.*Should have safety alarms such as over temperature, under temperature and hose disconnect. 132 Endoscopic Universal Cutter cum Stapler, Size : 30 mm Powered Endocutter with dual safety system that includes a manual over ride system, can accomodate all sizes of cartridges. Articulating , Shaft length -4.4 to 6 cm Firing stroke indicator and must have interchangable 6 rows of staple. 133 Expandable Biliary Metal Stent - Special design for low migration. Non-traumatic ends of the stent. Highly flexible delivery system with 180cm working length. Lower shortening, Markers at the middle and both ends. Stent dia : 10 mm, Stent Length : 60mm,80mm,100mm, Delivery system dia : 7F/8F (uncovered ) 134 Flow Fluid Warmer system , * Delivers blood and intravenous fluid to the patient atnormothermic temperature at wide range of flow rates from gravity flow rates to 50-5,000 ml/hr.*Keeps blood and fluids warm between 37–42°C. *Dedicated disposable triple lumen tubing that eliminates patient line cool down of infusate. *Single step programming of warmer. *Easy to setup and easy to use.* Displays set point of recirculating reservoir. *Audible and visual alarms if reservoir temperature reaches 43.9 OC. * Meets all AABB standards for blood warming. *Disposables must be latex free . *Should have built in safety audio and visual alarms for Check disposables, Add recirculating solution and Over Temperature.* Built in over temperature test button and alarm test button 135 Forceps, Sponge Holding, S.J. Curved, 23.5 cm 136 Forceps, Tissue, Judd-Allis, 19cm IS 7388 137 Intra-Aortic Balloon Catheter, *Catheter Size should be- 7.5Fr. * Balloon Sizes should be -34cc & 40cc. * Should be Balloon Length 221mm to 258mm. * Catheter Shaft should be Design : Co-Lumen. * Catheter Length of Proximal marker 6mm (Approx). * Outside Balloon coating should be –Silicone. * Guide wire Construction –SS with PTFE. * Guide Wire Size -0.025” * Balloons catheter should be FDA & CE Certified. 138 LANCET Disposable, Sterile, Individually wrapped, stainless steel, Provides quick, clean puncture, Straight side easily spreads blood on glass slide, Precision engineering, accuracy within 1/100mm in thickness, permanently sealed, Designed for one time use 139 PULSE OXYMETER WITH ACCESSORIES 140 PULSE OXYMETER WITH CAPNOMETER 141 SCISSORS, C.O.F., ROUND POINTS S.J.S.S. 12.5 CM 142 SCISSORS, C.O.F., ROUND POINTS S.J.S.S. 15 CM 143 SCISSORS, C.O.F., ROUND POINTS S.J.S.S. 20 CM 144 SCISSORS, C.O.F., ROUND POINTS S.J.S.S. 22 CM 145 STERILISER, HIGH PRESSURE DRESSING STERILIZER, HORIZONTAL VACUUM MODEL, TO STERILIZE DRESSINGS ETC. AT 1.4 KG. PRESSURE (1270 C) 250 MM. OR MORE VACUUM OBTAINED, STERILIZING CHAMBER MADE OF HEAVY GAUGE STEEL TINNED INSIDE DOOR AND FLANGES, ETC., MADE OF GUNMETAL / MILD STEEL / SS316. STRONG STEEL BOILER FOR GENERATING STEAM, BUILT BELOW STERILIZER, MOUNTED ON ALUMINIUM ENAMELED TUBULAR STEEL STAND, STERILIZER FITTED WITH PROTECTED WATER GAUGE, SAFETY VALVE, PRESSURE GAUGE, VACUUM GAUGE, STEM EJECTOR FOR PRODUCING VACUUM, ETC., AND WITH ALL NECESSARY INLET AND OUTLET COCKS WITH INSULATED HANDLES. DOOR, COCKS, VALVES AND OTHER FITTINGS, NICKEL PLATED. HAS ARRANGEMENT FOR SUBMITTING, THE DRESSINGS, ETC., TO A VACUUM BOTH BEFORE AND AFTER STERILIZATION. INTERNAL DIMENSIONS 900 MM. DEEP X 400 MM. DIA. (WITHOUT DRESSING DRUMS). IS 3829 Part 1 N.B.:THERE SHOULD BE A PLATE ON THE BODY OF THE STERILIZER IN WHICH THE MANUFACTURER SHOULD CERTIFY THAT “TESTED UNDER HYDRAULIC PRESSURE UPTO 2.45 KG.” IS 3829 Part 1 146 STERILIZER, HIGH PRESSURE DRESSING STERILIZERS HIGH PRESSURE DRESSING STERILIZER, UP-RIGHT MODEL, TO STERILIZE DRESSING ETC., AT 1.05 KG. PRESSURE (1210 C) WITH GUN-METAL FITTINGS. CONTAINER MADE OF HEAVY STEEL, TINNED INSIDE, COVER ON STRONG HINGE. COVER CLOSED BY SCREWS. FITTED WITH PROTECTED WATER GAUGE, SAFETY VALVE, PRESSURE GAUGE, ETC. AND WITH ALL NECESSARY INLET AND OUTLET COCKS WITH INSULATED HANDLES. COCKS VALVES AND OTHER FITTINGS NICKEL PLATED. INTERNAL DIMENSIONS 500 X 300 MM. DEEP DIA. (WITHOUT DRESSING DRUMS). ADDITIONAL TEMPERATE GAUGE SHOULD BE PROVIDED. N.B.- THERE SHOULD BE A PLATE ON THE BODY OF THE STERILIZER IN WHICH THE MANUFACTURER SHOULD CERTIFY THAT “TESTED UNDER HYDRAULIC PRESSURE UPTO 2-10 KG.” IS 3829 : Part 3 147 Syringe, Disposable hypodermic syringe 20ml 148 THERMOSENSETIVE POLYURETHANE ANTIMICROBIAL PAEDIATRIC TRIPLE LUMEN CENTRAL VENOUS CATHETER IMPREGNATED WITH RIFAMICIN & MICONAZOLE WITH NITINOL GUIDE WIRE -4.5FR- 6CM/12.5CM-20G/23G

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 04-09-2024 REVISED TECHNICAL DATA SHEET Other 17-09-2024
2 04-09-2024 CORRIGENDUM-1 BOQ 17-09-2024
3 11-09-2024 CORRIGENDUM 2 Other 17-09-2024

Key Value

Document Fees
Refer document
EMD
INR 100000.0 /-
Tender Value
Refer document

Attachment

FileName File Description File Size
Click here to download tender document Tender Notice 0 KB
Click here to download tender document Tender Document 0 KB
Click here to download tender document Tender Document 0 KB
Click here to download tender document Tender Document 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail