}

Shifting Of Pump Set And Other Allied E/M Accessories For New Pump Room At Shiekh Sarai Ph-Ii Bps In G.K. Constituency Ac-50., Delhi-Delhi

Boards / Undertakings / PSU has published Shifting Of Pump Set And Other Allied E/M Accessories For New Pump Room At Shiekh Sarai Ph-Ii Bps In G.K. Constituency Ac-50.. Submission Date for this Tender is 20-08-2024. Air Circulators Tenders in Delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

44729950
Shifting Of Pump Set And Other Allied E/M Accessories For New Pump Room At Shiekh Sarai Ph-Ii Bps In G.K. Constituency Ac-50.
Open Tender
Indian
Delhi
Delhi
20-08-2024

Tender Details

Shifting of Pump Set and other allied E/M accessories for New Pump Room at Shiekh Sarai PH-II BPS in G.K. Constituency AC-50. Constituency Ac-50. , Supply Of Vacuum Pump Set In Standard Construction With Bronze Impeller, Stainless Steel Shaft, Ci Body, Complete With Base Frame, Coupling, Coupling Guard Etc. Make:- Kirloskar/Djb Approved. Supply Of Squirrel Cage Induction Motor Tefc, 5 Hp 1500 Rpm, Suitable To Operate 400±10% Volts, 3 Phase 50Hz Ac Supply. Make: Kirloskar / Jyoti / Crompton/Djb Approved. , Supply Of 40 Mm Dia. G.I. Medium Class Pipe , Pipe Fittings Like Socket , Elbow , Tee , Union , X-Nipple , Gm Gate Valve 40 Mm Dia. ( 4 Nos.) 15 Mm Dia. ( 1 No) With Required Fittings And Base Frame , 500 Ltr Pvc Tankto Be Placed On Roof. Make:- Pipe : Jindal / Isi Marked ,Fittings:- R- Brand / Isi Maked,Gate Valve:- Sant/Leader/Isi Marked. , Dismantling Of Old Pump Set After Disconnecting From Suction And Delivery Pipeline, Decoupling With Motor, Removing Of Electric Connections From Motor I/C Taking Out Old Pump And Motor Lt Panel From Existing System & Shifting To Newly Made Pump House Etc., Closing Of Suction & Delivery Line With The Help Of Suitable Size Dead Flange. , Dismantling And Taking Out M S Base Frame From Rcc Foundation After Cutting Of Nut Bolts, Breaking The Damaged Rcc Foundation Of The Old Pump Set By The Help Of Concrete Breaker And Labour. Also Taking Out Malba From The Pump House By Manual Labour & Dumping The Same As Per Directions. , Internal / External Electrification For Following Works:- Internal Electrification Of The Pump House As Detailed Light Point / Fan Point / Exhaust Fan Point With 1.5 Sq Mm Pvc Insulated Copper Conductor Cable In Recess Surface As Required. (Sor Item Code: 31.1.3) , 5 / 6 Amp. 3 Pin Socket Plug Point. (Sor Item Code: 31.23.4) , 15 / 16 Amp. 3 Pin Socket Plug Point. (Sor Item Code: 31.23.5) , Providing & Fixing 20 W Led Fittings Including Making Connection As Required. (Sor Item Code: 19.1.1), Make:- Havells / Phillips / Bajaj , Providing & Fixing Of Gi Bracket Of 32 Mm Dia., Suitable Bend & Shifting Including Fixing Of Bracket With Ms Clamp On Wall By Grouting Of Both And Wiring As Required. , Providing & Fixing Of Mcb Db 63 Amp. Capacity In Sheet Metal Enclosure Made Out Of 16 Swg M.S. Sheet Duly Painted Having Insulator, Aluminum Link As Required. Make:- Ge / Crompton / Havells , Supply Of Ceiling Fan 1200Mm Sweep. (Sor Item Code: 20.1.2) Make:- Bajaj/Crompton/Havells , Exhaust Fan 380 Mm. (Sor Item Code: 20.2.2) Make:- Bajaj/Crompton/Havells , Supply Of 70 Watt Led Street Light Make:- Bajaj/Crompton/Havells , Supply Of Air Circulator Of 450 Mm Sweep. (Sor Item Code: 20.3.1) Make:- Bajaj/Crompton/Havells , Supplying & Laying 25 Mm X 5 Mm Gi Strip At 0.50 Mtr. Below Ground As Strip Earth Electrode Including Connection / Terminating With Gi Nut, Bolt, Spring, Washer Etc As Required. ( Jointing Shall Be Done By Overlapping & With 2 Sets Of Gi Nut Bolt & Spring Washer Space That 50 Mm) , Supply Of Ci Sluice Valves Non Rising With Ss Spindle Isi Pn 1.0 Is 14846 Flanged End Of Following Sizes Make:- Kirloskar/Ivc/Djb Approved I) 200 Mm Dia. , Ii) 150 Mm Dia. , Supply Of Ci Non Return Valve Without Bypass Swing Type Is:5312 Flange End Of 150 Mm Dia. (Sor Item Code: 4.9.7) Make:- Kirloskar/Ivc/Djb Approved , Supply Of Ci Foot Valve Swing Type With Strainer Is-4038 Flanged Of 200 Mm Dia. (Sor Item Code: 4.11.3) Make:- Kirloskar/Ivc/Djb Approved , Pipes & Special S/O M.S. Pipe Of Dia. 200 Mm. , S/O M.S Flange Of Dia. 200 Mm. , S/O M.S. D.F.90° Bend Of 200 Mm Dia. , S/O M.S. D.F.90° Bend Of 150 Mm Dia. , S/O M.S. Pipe Of 150 Mm Dia. , S/O M.S Flange Of Dia. 150 Mm. , S/O M.S All Flanged 150X150x150mm Dia. Tee. , Welding And Fitting Of Above Item As Per Site Requirement. , Supply Of Pvc Insulated Un Armoured Single Core Flexible Copper Cable For Working Voltage Up To 1.1 Kv As Per Is:694/2010 Of Size 50 Mm2. Make : Grandley / Gloster/Havells/Djb Approved , Supply Of Pvc Insulated Pvc Sheathed Armoured Aluminium Conductor Power Cable 1.1 Kv As Per Is-1554 ( Part-I) Of 3½ Corex 120 Mm² (Sor Item Code: 18.2.6) Make : Grandley / Gloster/Havells/Djb Approved , Making Of Rcc Foundation For 2 Nos. P/Sets & 01 No. Vacuum Pump Setwith All Material Like Steel, Cement, Concrete, Foundation Bolt & All Other Related Civil Work Required To Complete The Pump House As Per Site Requirement. , Supply Of Ms Base Frame, Flexible Tyre Coupling, Coupling Guard Suitable For Above Pump Sets. , Dol Starter Up To 5 H.P For 2 Nos Charging /Dewatering Purpose. P/Set Having 2 No. Mcb Tp 16 Amps Make:- Siemens/L&T/Abb/Schneider, 1 No. Contactor 16 Amps Tp 230 Vac Make:- Siemens/L&T/Abb/Schneider, 1 No. Overload Relay 2.8 - 4 Amps Make:- Siemens/L&T/Abb/Schneider, 1 No. Single Phase / Phase Reversal Protection Make:- Minilec / L&T / E1 , 2 Set Start / Stop Pb Make:- Siemens/L&T/Abb/Schneider , 2 Set On / Off / Trip Indication Make:- Teknic / L&T / Abb / Schneider. Power Factor Section Of 50 Kvar Apfc System Having :- 1 No. Mccb Tp 160 Amps Thermal Magnetic 36 Ka For Apfc Section Isolation Make: - Siemens/L&T/Abb/Schneider, 1 No. Microprocessor Based Apfc Relay 6 Steps Make:- Epcos / L&T / Abb / Beluk , 4 Nos. Capacitor Heavy Duty Mpp 10 Kvar 415 Vac Make:- Epcos / L&T / Abb / Beluk , 4 Nos. Capacitor Duty Contactor Suitable For 20 Kvar Or Higher 220 Vac Make:- Siemens/L&T/Abb/Schneider , 4 Nos. Mcb Tp 40 Amps Make:- Siemens/L&T/Abb/Schneider , 4 Nos. Auto / Manual Selector Switch With Led Indication Make:- Teknic / L&T / Abb / Schneider , 8 Set Start / Stop Pb In Manual Mode Make:- Teknic / L&T / Abb / Schneider , 2 Nos. Capacitor Heavy Duty Mpp 5 Kvar 415 Vac Make:- Epcos / L&T / Abb / Beluk , 2 Nos. Capacitor Duty Contactor Suitable For 10 Kvar Or Higher 220 Vac Make:- Siemens/L&T/Abb/Schneider, 2 Nos. Mcb Tp 20 Amps Make:- Siemens/L&T/Abb/Schneider, 2 Nos. Auto / Manual Selector Switch With Led Indication Make:- Teknic / L&T / Abb / Schneider , 4 Set Start / Stop Pb In Manual Mode Make:- Teknic / L&T / Abb / Schneider. Miscellaneous Material Having 1 No. Bus Bar With Heak Shrinkable Sleeves Make: - Hindalco / Ec Grade With Certificate, 1 No. Powder Coated Panel Enclosure With Accessories Make: - Djb Approved, 1 No. Control Wire. Make:- Djb Approved , 1 No. Power Wire. Make:- Djb Approved , 1 No. Dismantling Of Existing Panel, 1 No. Delivery And Installation Of New Panel, 1 No. Lugs / Glands As Required For Connections. Lighting Section Having 4 Nos. 10 Amps Sp Mcb For Lights/Fans Etc Make:-Siemens/L&T/Abb/Schneider , Co2 Type Fire Extinguisher Isi Marked Conforming To Is: 15683, Complete With Delivery Hose Horn, Wheel Type Release Valve, Locking Arrangement, Operation Manual And Bracket, Operating Temperature:-300 C To +600 C Of 4.5 Kg: Life Guard Make , Fabrication / Supply Of Retro Reflective Sign Board Made Out Of 40 X 40 X 6Mm Ms Angle Iron Frame & 2 Mm Thick Ms Sheet & 50 Mm Dia. Gi Pipe For Supporting The Board. The Size Of Board 4 Mtr. X 1Mtr. Including Grouting Of Board In Proper Way. The Board Shall Be Duly Painted & Matter To Be Written As Per The Direction Of Engineer In Charge. , Supply Of 3Mm Thick High Voltage Insulation Mats, Size 1M X 2M. , Installation, Testing & Commissioning Of All Above E&M Equipments, After Shifting From Old Pump Room To New Pump Room & Laying Of Pipe Line, Cable, Job Also Includes Cost Of Packing, Cartage, Painting, Rubber Packing, Watch & Ward & Freight, And Minor Item/Jobs Like Reducer, Taper, Nut Bolts Etc. Required For Shifting Old Pump Room To New Pump Room To The Satisfaction As Per The Instruction Of Engineer In Charge.

Key Value

Document Fees
INR 500 /-
EMD
INR 40100.0 /-
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail