}

Tender Document For Laboratory Equipments Biochemistry, I.H.B.T, Pathology Year, 2024-25, Ahmedabad-Gujarat

Government Departments has published Tender Document For Laboratory Equipments Biochemistry, I.H.B.T, Pathology Year, 2024-25. Submission Date for this Tender is 02-09-2024. Laboratory Equipment Tenders in Ahmedabad Gujarat. Bidders can get complete Tender details and download the document.




Tender Notice

44665534
Corrigendum : Tender Document For Laboratory Equipments Biochemistry, I.H.B.T, Pathology Year, 2024-25
Open Tender
Indian
Gujarat
Ahmedabad
02-09-2024

Tender Details

Tender Document For Laboratory Equipments Biochemistry, I.H.B.T, Pathology Year, 2024-25; 1 Acetone powder -(for Rothera test) AR/GR Quality . 250gms pack size gm 2 Total Bilirubin Liquid Stable Ready to use R1 & R2 Reagents. Colorimetric Diazo End Point 540 nm Method. Onboard Stability of Working Reagents equals to 21 days. Linearity not less than 20 mg/dL. Compatible with Erba XL series Biochemistry fully -Auto Analyser. ml 3 Direct Bilirubin Liquid Stable Ready to use R1 & R2 Reagents. Colorimetric Diazo End Point 540 nm Method. Onboard Stability of Working Reagents equals to 21 days. Linearity not less than 15 mg/dL. Compatible with Erba XL series Biochemistry fully -Auto Analyser. ml 4 Ammonium Sulphate AR / GR / Excellar Quality with All Assay Details 500 gm packs gm 5 Sodium Nitropruside. AR / GR / Excellar Quality with All Assay Details. 500 gm Packs gm 6 Sodium Hydroxide. AR / GR / Excellar Quality with All Assay Details. In Pellets or Flakes 500 gm Packs gm 7 Cleaning Solution for cuvettes. 1 x 5000 mL packs ml 8 Hand and Skin Disinfectant 100 ml should contain Chlorhexidine gluconate IP 2.5 percent v/v equivalent to 0.5 percent w/v Chlorhexidine gluconate,Ethanol IP 75 percent v/v, 500 ml bottle unit 9 Gloves -Acid proof All sizes unit 10 Battery for UPS 12 Volts unit 11 Steel Trolley 1.5 feet X 3 feet, Height 3 feet, with wheel unit 12 Centrifuge - 36 tubes • Step less speed regulator. • Safety Lid interlocks to prevent cover opening during centrifugation. • Digital speed meter and 0-60 minutes digital countdown timer. • Interchangeable Head of 36 tubes. • Tube capacity: 15 ml. • Max. Capacity of 5000 rpm without rotor and heads. • Calibration Certificate. 5 years AMC rate is provided• For imported item, Calibration certificate. unit 13 SPECTROPHOTOMETER Double beam U V Light, Wavelength 340-700nm, 6 filter position - compatible with 210 - 250 V power supply -digital display with atleast 1000 result storage capacity -aspiration and quartz square cuvette mode, 1 hour backup UPS, 6 cuvettes extra to be supplied, ISO/CE unit 14 Laboratory refrigerator (400 litres) • With transperent glass/plastic door with key lock for convenient sample viewing. • Automatical defrosting and melt water evaporation • Height- adjustable shelves • Easy accessible control panel with key switch • Easy-to-read LED temperature display • Safety device to prevent freezing • Alarms for High/Low temperature variation • Low-noise compressor unit 15 Fully Automated Biochemistry Analyser • Floor model, random accessfully programmable open system. • Throughput: More than 800 tests per hour with ISE. • Spectral range must be 340-800 nm or better • Intended use (not limited to): Estimation of Plasma glucose, S. Creatinine, S. Urea, S. GPT, S. GOT, S. ALP, S. Total Protein, S. Albumin, S. Total Bilirubin, S. Direct Bilirubin, S. Calcium, S. Sodium, S. Potassium, S. Lithium, S. Phosphorus, S. Uric acid, S. Magnesium, S. Cholesterol. S. Triglyceride, S. HDL, S. LDL • Having facility for clotdetection, bubble detection, auto dilutionandstat sample. • Capable of sampling from different types of tubes. • Continuous loading of samples. • Minimum 50 biochemistry test reagent loading capacity at a time. • The instrument should have maintenance logs and data storage facility built in quality control programs like LJ chart, Mean and SD calculation and QC data storage facility. • On-board reagent chamber refrigeration. • Bidirectional LIS compatibility. • Assay Type/Methodology: End point, Rate reaction (Fixed time), Kinetic, Single and dual reagent chemistries, Monochromatic/ Bichromatic, Linear/ Non linear with one point or multipoint calibration. unit 16 Fully Automated Biochemistry Analyser • Floor model, random accessfully programmable open system. • Throughput: More than 400 tests per hour with ISE. • Spectral range must be 340-800 nm or better • Intended use (not limited to): Estimation of Plasma glucose, S. Creatinine, S. Urea, S. GPT, S. GOT, S. ALP, S. Total Protein, S. Albumin, S. Total Bilirubin, S. Direct Bilirubin, S. Calcium, S. Sodium, S. Potassium, S. Lithium, S. Phosphorus, S. Uric acid, S. Magnesium, S. Cholesterol. S. Triglyceride, S. HDL, S. LDL • Having facility for clotdetection, bubble detection, auto dilutionandstat sample. • Capable of sampling from different types of tubes. • Continuous loading of samples. • Minimum 50 biochemistry test reagent loading capacity at a time. • The instrument should have maintenance logs and data storage facility built in quality control programs like LJ chart, Mean and SD calculation and QC data storage facility. • On-board reagent chamber refrigeration. • Bidirectional LIS compatibility. • Assay Type/Methodology: End point, Rate reaction (Fixed time), Kinetic, Single and dual reagent chemistries, Monochromatic/ Bichromatic, Linear/ Non linear with one point or multipoint calibration. unit 17 FREE T3 KIT Compatible with unicel DxI 600 Access Immunoassay System, Beckman Coulter machine ml 18 FREE T4 KIT Compatible with unicel DxI 600 Access Immunoassay System, Beckman Coulter machine ml 19 TSH KIT Compatible with unicel DxI 600 Access Immunoassay System, Beckman Coulter machine ml 20 FERRITIN KIT Compatible with unicel DxI 600 Access Immunoassay System, Beckman Coulter machine ml 21 VITAMIN B12 KIT Compatible with unicel DxI 600 Access Immunoassay System, Beckman Coulter machine ml 22 VITAMIN D3 KIT Compatible with unicel DxI 600 Access Immunoassay System, Beckman Coulter machine ml 23 HS TROPONIN-I KIT Compatible with unicel DxI 600 Access Immunoassay System, Beckman Coulter machine ml 24 HYBRITECH PSA KIT Compatible with unicel DxI 600 Access Immunoassay System, Beckman Coulter machine ml 25 FREE T3 CALIBRATOR Compatible with unicel DxI 600 Access Immunoassay System, Beckman Coulter machine ml 26 FREE T4 CALIBRATOR Compatible with unicel DxI 600 Access Immunoassay System, Beckman Coulter machine ml 27 TSH CALIBRATOR Compatible with unicel DxI 600 Access Immunoassay System, Beckman Coulter machine ml 28 VITAMIN B12 CALIBRATOR Compatible with unicel DxI 600 Access Immunoassay System, Beckman Coulter machine ml 29 VITAMIN D3 CALIBRATOR Compatible with unicel DxI 600 Access Immunoassay System, Beckman Coulter machine ml 30 FERRITIN CALIBRATOR Compatible with unicel DxI 600 Access Immunoassay System, Beckman Coulter machine ml 31 HS TROPONIN-I CALIBRATOR Compatible with unicel DxI 600 Access Immunoassay System, Beckman Coulter machine ml 32 HYBRITECH PSA CALIBRATOR Compatible with unicel DxI 600 Access Immunoassay System, Beckman Coulter machine ml 33 ACCESS SYSTEM CHECK SOLUTION Compatible with unicel DxI 600 Access Immunoassay System, Beckman Coulter machine ml 34 ACCESS SUBSTRATE 4X Compatible with unicel DxI 600 Access Immunoassay System, Beckman Coulter machine ml 35 CITRANOX Compatible with unicel DxI 600 Access Immunoassay System, Beckman Coulter machine ml 36 CONTRAD-70 Compatible with unicel DxI 600 Access Immunoassay System, Beckman Coulter machine ml 37 REACTION VESSELS Compatible with unicel DxI 600 Access Immunoassay System, Beckman Coulter machine unit 38 WASH BUFFER Compatible with unicel DxI 600 Access Immunoassay System, Beckman Coulter machine ml 39 Interleukin-6 kit Compatible with unicel DxI 600 Access Immunoassay System, Beckman Coulter machine ml 40 Interleukin-6 quality control Compatible with unicel DxI 600 Access Immunoassay System, Beckman Coulter machine ml 41 Interleukin-6 Calibrator Compatible with unicel DxI 600 Access Immunoassay System, Beckman Coulter machine ml 42 Access PCT Kit Compatible with unicel DxI 600 Access Immunoassay System, Beckman Coulter machine ml 43 Access PCT Calibrator Compatible with unicel DxI 600 Access Immunoassay System, Beckman Coulter machine ml 44 WASH 2 (Rising solution) Compatible with ESCHWEILER, Combiline Blood Gas Analyzers ml 45 BGA 3 (calibratioan solution) Compatible with ESCHWEILER, Combiline Blood Gas Analyzers ml 46 BGA 4(calibratioan solution) Compatible with ESCHWEILER, Combiline Blood Gas Analyzers ml 47 CAL 3(calibratioan solution) Compatible with ESCHWEILER, Combiline Blood Gas Analyzers ml 48 CAL4(calibratioan solution) Compatible with ESCHWEILER, Combiline Blood Gas Analyzers ml 49 PROTEN REMOVER Compatible with ESCHWEILER, Combiline Blood Gas Analyzers ml 50 PO2 MEMBRANE SHELL Compatible with ESCHWEILER, Combiline Blood Gas Analyzers unit

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 24-08-2024 02-09-2024

Key Value

Document Fees
INR 5000 /-
EMD
INR 100000.0 /-
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail