}

Bids Are Invited For Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Rr Site 5 And 6; Non Radiation Area Shifting Of Piping Material From Welding Shop To Site And Erection Of Pipe And Pipe Fittings For Details Refer Bo, Kota-Rajasthan

Department Of Atomic Energy has published Bids Are Invited For Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Rr Site 5 And 6; Non Radiation Area Shifting Of Piping Material From Welding Shop To Site And Erection Of Pipe And Pipe Fittings For Details Refer Bo. Submission Date for this Tender is 30-08-2024. Carbon Steel Pipe Tenders in Kota Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

44665455
Bids Are Invited For Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Rr Site 5 And 6; Non Radiation Area Shifting Of Piping Material From Welding Shop To Site And Erection Of Pipe And Pipe Fittings For Details Refer Bo
Open Tender
NCB
Rajasthan
Kota
30-08-2024

Tender Details

Bids Are Invited For Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site 5 and 6; Non Radiation Area Shifting of piping material from welding shop to site and erection of pipe and pipe fittings for details refer BOQ item No 1 in scope.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site 5 and 6; Non Radiation Area Fabrication and erection including welding of structure including material handling from welding shop to site for details refer BOQ i.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site 5 and 6; Non Radiation Area Dismantling of pipe and structural steel items viz pipelines platform ladder hand railing etc for details refer BOQ item No 3 in scop.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site 5 and 6; Fabrication of pipe clamp set for on line leak rectification in system piping for details refer BOQ item No 4 in scope of work and 01 bid quantity is eq.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site 5 and 6; Shifting of material from CMM store to Operating Island or deposition of scrap to CMM store for details refer BOQ item No 5 in scope of work and 01 bid .. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site 5 and 6; Non Radiation Area SW or FW welding of SS to SS pipe and pipe fittings with GTAW process for details refer BOQ item No 6 in scope of work and 01 bid qua.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site 5 and 6; Non Radiation Area SW or FW welding of CS to CS pipe and pipe fittings with GTAW or SMAW process for details refer BOQ item No 7 in scope of work and 01.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site 5 and 6; Non Radiation Area BW or NW for Alloy to CS pipe or Alloy to Alloy pipe and pipe fittings by GTAW or SMAW process for details refer BOQ item No 8 in sco.. , Repair, Maintenance, details refer BOQ item No 8 in sco.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site 5 and 6; Non Radiation Area BW or NW welding of CS to CS piping by GTAW or SMAW process for details refer BOQ item No 9 in scope of work and 01 bid quantity is e.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site 5 and 6; Non Radiation Area BW or NW welding of SS to SS piping with GTAW process for details refer BOQ item No 10 in scope of work and 01 bid quantity is equal .. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site 5 and 6; Non Radiation Area BW or NW welding of CS to SS piping with GTAW process for details refer BOQ item No 11 in scope of work and 01 bid quantity is equal .. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site 5 and 6; Non Radiation Area Dye Penetrant Test of weld joints for details refer BOQ item No 12 in scope of work and 01 bid quantity is equal to 3200 ID; As per S.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site 5 and 6; Non Radiation Area Red oxide primer coating on fabricated steel structures for details refer BOQ item No 13 in scope of work and 01 bid quantity is equa.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site 5 and 6; Non Radiation Area Supply and installation of Pin Type Anchor Bolts with nut and size M10X75 mm for details refer BOQ item No 14 in scope of work and 01.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site 5 and 6; Non Radiation Area Supply and installation of Pin Type Anchor Bolts with nut and size M12X100 mm for details refer BOQ item No 15 in scope of work and 0.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site 5 and 6; Non Radiation Area Supply and installation of Pin Type Anchor Bolts with nut and size M16X100 mm for details refer BOQ item No 16 in scope of work and 0.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site 5 and 6; Pre Heat treatment of welding joint with induction coil heating method for details refer BOQ item No 17 in scope of work and 01 bid quantity is equal to.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site 5 and 6; Post Weld Heat treatment of welding joint with induction coil heating method for details refer BOQ item No 18 in scope of work and 01 bid quantity is eq.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site 5 and 6; Radiation Area Shifting of piping material from welding shop to site and erection of pipe and pipe fittings for details refer BOQ item No 19 in scope of.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site 5 and 6; Radiation Area Fabrication and erection including welding of structure including material handling from welding shop to site for details refer BOQ item .. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site 5 and 6; Radiation Area Dismantling of pipe and structural steel items viz pipelines platform ladder hand railing etc for details refer BOQ item No 21 in scope o.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site 5 and 6; Radiation Area SW FW welding of SS to SS pipe and pipe fittings with GTAW process for details refer BOQ item No 22 in scope of work and 01 bid quantity .. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site 5 and 6; Radiation Area SW or FW welding of CS to CS Site 5 and 6; Radiation Area SW or FW welding of CS to CS pipe and pipe fittings with GTAW and SMAW process for details refer BOQ item No 23 in scope of work and 01 b.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site 5 and 6; Radiation Area BW or NW welding of CS to CS piping by GTAW or SMAW process for details refer BOQ item No 24 in scope of work and 01 bid quantity is equa.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site 5 and 6; Radiation Area BW or NW welding of SS to SS piping with GTAW process for details refer BOQ item No 25 in scope of work and 01 bid quantity is equal to 7.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site 5 and 6; Radiation Area BW or NW welding of CS to SS piping with GTAW process for details refer BOQ item No 26 in scope of work and 01 bid quantity is equal to 1.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site 5 and 6; Radiation Area Dye Penetrant Test of weld joints for details refer BOQ item No 27 in scope of work and 01 bid quantity is equal to 1200 ID; As per Scope.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site 5 and 6; Radiation Area Red oxide primer coating on fabricated steel structures for details refer BOQ item No 28 in scope of work and 01 bid quantity is equal to.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site 5 and 6; Radiation Area Supply and installation of Pin Type Anchor Bolts with nut size M10X75 mm for details refer BOQ item No 29 in scope of work and 01 bid qu.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site 5 and 6; Radiation Area Supply and installation of Pin Type Anchor Bolts with nut size M12X100 mm on concrete structures for details refer BOQ item No 30 in sco.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site 5 and 6; Radiation Area Supply and installation of Pin Type Anchor Bolts with nut and size M16X100 mm for details refer BOQ item No 31 in scope of work and 01 bi.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site 5 and 6; Radiation Area Pre Heat treatment of welding joint with induction coil heating method for details refer BOQ item No 32 in scope of work and 01 bid quant.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site 5 and 6; Radiation Area Post Weld Heat treatment of welding joint with induction coil heating method for details refer BOQ item No 33 in scope of work and 01 bid.. Total Quantity :

Key Value

Document Fees
Refer document
EMD
INR 447680.0 /-
Tender Value
INR 2.23 Crore /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail