Construction Of Model Storage Facilities For Seized Narcotics Drugs And Psychotropic Substances, Dhanbad, dhanbad-Jharkhand

Government Departments has published Construction Of Model Storage Facilities For Seized Narcotics Drugs And Psychotropic Substances, Dhanbad. Submission Date for this Tender is 10-08-2024. Footwears Tenders in dhanbad Jharkhand. Bidders can get complete Tender details and download the document.




Tender Notice

44556638
Construction Of Model Storage Facilities For Seized Narcotics Drugs And Psychotropic Substances, Dhanbad
Open Tender
Indian
Jharkhand
Dhanbad
10-08-2024

Tender Details

Construction of Model Storage Facilities for Seized Narcotics Drugs and Psychotropic Substances, Dhanbad-Earthwork in excavation in foundation trenches in ordinary soil (vide classification of soil item-A) and disposal of excavated earth as obtained to a distance upto 50 M. including all lifts, levelling, ramming the foudation trenches, removing roots of trees, shrubs all complete as per approved design, building specification and direction of E/l. 2 Extra for earth work in hard soil as per specification and direction of E/I (Vide classification of soil item_B) 3 Earth Filling in foundation trenches and plinth in layers not exceeding 150mm thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation of foundation trenches withina lead of 50Mand lift of 1.5M all complete as per building specification and direction of E/I. (mode of measurement compacted volume) 4 Supplying and stacking of good earth at site including royalty and carriage upto 5 k m lead complete (earth measured in stacks will be reduced by 20%for payment). 5 Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials, labour, royalty and taxes all complete as per building specification and direction of E/l (Mode of measurement complacted volume). 6 Providing designation 75B one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/l. 7 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering .all work up to plinth level:1:2:4 (1Cement ;2 coarse sand (zone-III):4 grade stone aggregate 20 mm normal size) 8 Providing and laying damp-proof course 50 mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5 mm nominal size). 9 Providing designation 75 B brick work in C.M. (1:6) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/l. 10 Providing designation 75B brick work in C.M. (1:3) in superstructure with approved quality of clean coarse sand of F.M. 2 to2.5 including providing 10 mm thick mortar joints cost of screening materials , scafolding , raking out joints to 15mm depth curing, taxes and royalty all complete as per building specification and direction of E/l. 11 Providing and laying in position specified grade ofreinforced cement concrete,excluding the cost of centering,shuttering ,finising and reinforcement- all work up to plinth level,1:1.5:3(1 cement : 2 coarse sand: 4 graded stone aggregate 20mm normal size). 12 Reinforced cement concrete work min wall (any thikness), including attached pilasters,buttresses,plint and string courses,fillets,column,pillars,piers,abutments,posts and struts etc. above plint level up to floor five level, excluding cost of centering, shuttering ,finishing and renforcement: 1:1.5:3( 1 cement : 1.5 coarse sand (zone-III) :3 grade stone aggregate 20 mm normal size). 13 Reinforced cement concrete work in beam, suspended floors,roofs having slope up to150 landings,balconies,shelves, chajjas,lintels, bands, plain window sills,staircases and spiral stair cases above plinth level up to floors five level,excluding the coast ofcentering,shuttering,finishing and reinforcement ,with 1:1.5:3(1 cement :1.5 coarse sand (zone III) :3 graded stone aggregate 20 mm normal size). 14 Centering and shuttering including strutting,propping etc.and removel of form for. 15 Foundation 16 Column 17 linten beams - 18 Roof slab 19 Providing, hoisting and fixing above plinth level up to floor five level precast Reinforced cement concrete in shelves, including setting in cement mortar 1:3 (1cement : 3 coarse sand), cost of required centering, shuttering and finishing with neat cement punning on exposed surfaces but , excluding the cost of reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III): 3 graded stone aggregate 20 mm nominal size). 20 Providing TMT reinforcement of 8mm dia rods as per approved -do-TMT Fe 500(only valid for tata,sail,jspl,electrosteel,bokaro and vizag) 21 Providing TMT reinforcement of 10mm, dia rods as per approved -do-TMT Fe 500(only valid for tata,sail,jspl,electrosteel,bokaro and vizag) 22 Providing TMT reinforcement of 12mm,16mm & 20mm dia rods as per approved -do-TMT Fe 500(only valid for tata,sail,jspl,electrosteel,bokaro and vizag) 23 Providing 12mm thick cement plaster (1:3)with clean coarse sand of F.M. 1.5 and including cost of screening, curingwith all leads and lifts of water, scaffolding, taxes and royalty all complete as per building specification and direction of E/I 24 Providing 12mm cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. 25 Providing 6mm thick cement plaster (1:4) in ceiling with clean coarse sand of F.M. 1.5 -do- 26 Providing 1.5 mm. cement punning including curing carrage of water withall leads and lifts as per buildingspecification and direction of E/I 27 Making 6mm X 6mm grooves in plaster surface over wall truely horizontal or vertical as specified at regular intervals at all heights including cleaning, finishing, scaffolding and curing with all leads and lifts of water all complete as per building specification and direction of E/I. 28 Water proofing for Old and New Roof Slab Providing and laying water proofing treatment on roof slab by applying two Component, factory designed, ready to use, acrylic modified flexible material applied wth brush, roller or spray for water proofing coating as Per ....Mier specificatIons with following steps (a)surface preparation -Providing and cleaning o1 concrete ...lece le remove dust, oil, grease including removal of existing loose paint r coating, and cement laitance by cleaning with comer..ed air 8 water let including all materials, labour, tools complete Ponding test to be done after plugging all outlets and to be checkedtrodentify seepage eakage On identification of seeps cem t be done with non shrink expanding admixt e a Ind, t 1MYK c g / Dr Fout/Fosroc or equive teems such as those betwe be chamfered with 15 1 41 admixed with ac Fixit or equivalent slum, of acrylic concretein baserovtartg and repaving of all c arapet wall and the roof slab et 50 mm fillet of mortar (Cement sand mer of Sika/ Fosroc/MYK SchomberglDr chamfering a prime coat shall be given with the Repairing surface irregularities, damaged ad cracks if any, with an acrylic polymer modified repair moile, including a coat of bonding agent of the same with cement slurry inctC01; all material, labour, tools complete (b)1st Coat - APOrlit coat of two component acrylic modified, ready to use. flexible come s material on surface saturated dry roof and inside wall of Par ll upto 600 mm by brush or roller After 1st coat re. pgplaisesd c@lot,h5t: kla9y,sw,nheincothaet rost, itahyee r of application , 45 still green 1st coat purpose of measure he entire treated surface will be measured 4, (c) 2nd Coat -To apply g02 coat of two component acrylic rnorAdmir* ready to use, flexible come tonal right angle to the 140,af,•:,-- over the glass fibre laid surface*d alepld be * applied VW Sgmt/coat For the purpose of rnikeSCiretfleritthe entireteaterfstiface will be measured After three days of drying the 2nd coat , the rain water outlets to be plugged and ponding test to be done for 48 hours to identify seepage, leakage from soffit and found necessary rectification to be done as per satisfaction of E/C The waterproof coating to be protected from damage before screed over it Water proofing Brand - Sika Topseal 109hi / Fosroc Brushbond RI. Dr Feet Picliflin 2K 1 MYK Actuate TG Product Performance Chemical Base F. A Acrylic copolymer, Part B: Specially graded cementitious powder -D011,4 1.6 fief, (mixed density) at 427°C Tensile Strength -2 N/mm2 atter 28 days (with Fibre cloth) (According to ASTM D 2370) Pullout Bond Strength -2 N/mm2 (concrete failure) (According to ISO4624) Slant-Shear Bond Strength -4 N/mm2 (According to FIP 5 15) Elongation at Break -35% without Fibre Cloth and 20% with Fibre Cloth (According to ASTM D 2370) (d) Protection of treated surface with PCC •- The treated surface should be covered with 25mm/50mm PCC of M-20 grade(1.1.5 3) with proper slope ( 1 120) towards the rain outlets in alternatepanels of 2 mt x 2mt keeping 6 mm gap between the panel joint Integral water proofing admixture conforming to IS 2645 @ of 100 ml per bag of of cement to be added in the screed concrete (paid separately for this items) All corners shall be chamfered with 150mm X 150 mm fillet The rainwater outlets shall be just leveled with the screed concre toe ure smooth discharge of water - the peripheral gaps be en p pi o and concrete surface should be packed pro with n c e and tiurpheral mouth to be sealed with ure Pvt Ltd. / MYK Schomb Fixit/Fosroc For the purpose of measurement the ed surface will be measured ensitive epoxy putty o (e)Groove of PC should be filled with Polysulphide Sealant. (Paid Separate* d - Sika India Pvt Ltd / MYK Schomberg / Dr FixitiFosroc W for five years 29 Covering of treated surface with PCC .- Providing 25 mm thick Cement Alf, Concrete M20 1:1. :3) maintaining slope in alternate 2 mt x 2 mt panels with aaprove. of stone chips of 20 mm to 6 mm size graded and cleaned sand 2.5 to 3 including screening,shuttering,and mixing cement concret . fixer with admixture of integral water proofing and placing in posi . ing curing,taxes and royality all complete as per building specifi nd direction of Ell. Panels that has been left shoul be casted next dysThere should be 6 mm gap between Panels .Brand Sika _Plastocrate Aus,MYK proof WP10, Fosroc- Conplast X421 lc& Dr Fixit Pidiproof LW+ 30 Providing and filling of 6 mm thick Groove between 25 mm PCC Panels with Polysulphide Sealant (Poring Grade)as Per drawings and technical specifications and direction of E in Charge (with 18% GST Polysulphicle Fosroc-Thoflex 600.Dr Fixit Pidiseal PS(42P) !MraYndK -Seikaal PS or Euivalent 31 Making plinth protection 50mm thik of cement concrete1:3.:6 (1 cement :3 coarse sand :6 grade stone aggregate 20 mm normal size) over75 mm thik ded dry brick ballast 40mm normal size well rammed and cansoldiated and grouted with fine sand includingnessesary excavation leving and dressing & finishing the top smooth. 32 Providing and laying Doublecharge vitrified floor tiles in different sizes(thickness to be specified by the manufacturer) with water absorptionless than 0.08% and conforming to IS: 15622 / ISO 13006 of approvedmake, in all colours and shades, laid on 20mm thick cement mortar 1:4(1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm . 33 Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.Glazed Vitrified tiles Matt/Antiskid finish of size 600X600 34 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 35 Granite of any colour ,18 mm thick (slab area above 0.50 sqm) 36 Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. 37 Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. 38 Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : New work (two or more coats) over and including water thinnable priming coat with cement primer 39 Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm 40 Lettering with black japan paint of approved brand and manufactured 41 Suppling, fitting and fixing good quality, well dressed and well seasoned sal wood work in chaukhat in doors, windows, skylight, fanlights and celetial windows openings, including wedge over clamps all complete including application of two coats of wood preservative of approved quality on the surface butting walls and lintels all complete as per building specification and direction of E/l 42 Supplying, fitting and fixing 35mm thick solid core type decorative double leaf flush door shutter with both sides decorative veneered with black board core bended with high quality phenol formal dehydes synthetic resin of standard make with Aluminium fittings such as hinges, tower bolts, handle, cleats and sand blocks and taxes all complete as per building specification and direction of E/l. 43 Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardwares and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Three track three panels sliding window with fly proof S.Swire mesh (Two nos. glazed & one no. wire mesh panels)made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.75 sqm). 44 Structural steel work in single section ,fixed with or without connecting plate,including cutting,hoisting,fixing in position and applying a primer coat of approved steel primer all complete 45 Providing two coats of synthetic enamel paint of approved shade and make over steel surface including cleaning the surface thoroughly, scaffolding and taxes all complete as per building specification and direciton of E/l. 46 Carriage Of Materials 47 Bricks=8 km(7+1) 48 Sand=30 km 49 Stone chips =20 km 50 Supplying and fixing C.I. cover without frame for manholes : 560 mm diameter C.I. cover (medium duty) the weight ofthe cover to be not less than 58 kg 51 Making soak pit 2.5 m diameter 3.0 m deep with 45x45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter and 1.20 m long complete as per standard design.with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 52 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge 150 mm nominal size dia 53 Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. 54 Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. 55 Supplying, filling, spreading & leveling coarse sand of size ange 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer for all leads & lifts, all complete as per direction of Engineer -in- charge. 56 Cost of Drilind 200 mmx165mmx125 mtr.deep bore well in all kind of Soil and rock in rural area for instalation of pump set with Hydrolic DTH Rig machine all complete including all materials, tools,driling rig,air compressureand equipmentsas well as fule, lubricantsand cost of transportation of rig machine annd other vehical up to Site. Basic Rates 57 From 0 - 50 meter 58 From 51 - 125 meter 59 Supply of 200mm dia X 2.00m long UPVC casing pipe conferming to IS : 12818 : 2016 (CML No. 5543459) latest revision including carriage. 60 Supplying all materials, labours, equipments for lowering blue UPVC casing pipes as casing for protecting the sides from falling during the process of drilling all complete including carriage of materials to work site. 61 Supplying all tools, equipments and labour and doing washing, flushing and development of drilled tube well to give clean and clear water all complete as per direction of E/I. 62 Supplying 100mm dis submersible pump sets confirming to 8034 and motor confirming to IS 9283 pump shall be suitable for various delivery head and discharge with stainless steel pump shaft and polypropylene/noryl impeller. Motor suitable for working on 415 + 10, 3HP, 50 Hz, AC supply with cable guard, thurst carbon/fiber bearing to withstand entire hydraulic thurst, water proof winding shall be provided. The pump set shall be suitable for diret coupling Pump shall have suitable outlet as per manufacturers design. Anti thurst stream lined non return valve shall be provided with pump, 3 meter submersible copper conductor cable in single/double run shall be provided with each pump. Submersible pump set 100mm dia (with Polypropylene/ Noryl Impeller) up to 20 stages 2 HP 63 PVC/XLPE insulated PVC sheathed heavy duty, armoured electrical cable with aluminium conductor for working voltage up to and including 1100 volts.(Conforming to IS:1554, part-1)6sq.mm, 2 core. 64 63 amp. Four pole, on load change over switch in sheet enclousre with side handle operation. 65 Medium density polyethylene pipe (MDPE pipe) in standard length with necessary Jointing material like mechanical connector i.e., thread/insert joint / quick release coupler joint / compression fitting joint or flanged joints confirming to ISO: 4427 : 1996MDPE pipe of material grade PE-80 PN16 (dia in mm) 40 mm dia 66 Polythene water storage tank of mark with cover and suitable locking system in double layer confirming to IS: 12701-1996 with latest revision. 67 Providing & fixing brass stop cock of approved quality all complete as per specification and direction of E/I. (A) Brass stop cock 68 (c) 25 mm dia 69 (d) 32 mm dia 70 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes joining of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of E/I. (Approved Brand - ASTRAL/ SUPREME) Concealed work including cutting chases and making good the wall etc.. 71 15mm dia 72 20mm dia 73 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 74 25 mm dia 75 32 mm dia 76 Supplying, fitting and fixing 40 mm high viterous white glazed earthen ware I.W.C. with p trap of Parry Hindustan or any other I.S.S. make including supplying & fixing 15 litres C.I. mosquito proof low down flushing cistern of approved make with complete fittings with C.I. handle and R.S. or bracket with telescopic flush pipe with brass coupling and plumbers joints spindle stop cock of approved quality weight not less than 450 grms. , 15 mm P.V.C. alkathene pipe 45 cm long with brass coupling at both ends and white/ black plastic solid state seal and lead of commander/ cuckoo or other I.S.S. make with hinges or screw etc. painting pipe and cistern etc. with 2 coats of approved paint over a coat of red oxide primer etc. all complete as per specification and direction of E/l. (B) E.W.C. With S trap(b)12.5 lit. low level P.V.C. cistern 77 Supplying, fitting and fixing flat back or angular, lipped front viterous white glazed earthenware urinal of Hindustan Parry or any other approved I.S.S. make with all fittings with C.I. or R.S. brackets, standard size G.I. flush pipe with fitting clamps, 15 mm C.I. body brass spindle stop cock of approved quality weight not less than 400 grms. , 15 mm P.V.C. alkathene pipe 450 mm long with brass coupling at both ends and doing plumber joints including painting of exposed part with 2 coats of approved paint over a priming coat of red oxide, cutting wall and floor, making good the same etc. all complete as per specification and direction of E/l.(A) Flat back or standing corner ( 450 mm x 350 mm ) 78 Supplying, fitting and fixing viterous white glazed earthen ware wash hand basin of Parry or Hindustan or any other I.S.S. approved make supported on pointed c.l. or R.S. brackets 32m C.I. brass waste 15mm dia C.I. body brass spindle stop cock of approved quality of weight not less than 350grms., 32mm P.V.C. waste pipe 750mm long with brass coupling at one end and making plumber joints etc. all complete as per specification and direction of E/l. 79 Providing and fixing lead connection pipe with heavy quality brass coupling 2 Nos. at both ends etc. all complete as per specification and direction of E/l .(ii) 15 mm dia and 45 cm long 80 Providing and fixing N.P/C.P brass/P.V.C porcelain shower rose of 15mm inlet etc. all complete as per specification and direction of E/l (c) 150 mm dia P V C shower 81 Providing and fixing male ended 15 mm dia brass bib cock of approved quality ( wt not less than 350 gms ) with extra socket all complete as per specification and direction of E/l . 82 Providing and fixing 15mm size C.P brass pillar cock (Weight not less than 350 gms) C.I body brass spindle pillar cock of approved quality as per spcification and direction of E/l. (b) C.I. body brass spindle 83 Supplying, fitting and fixing the following items complete with all materials as per specification and direction of E/l. 84 Glass shelf with C.P brass raili)600 x 125 mm glass shelf complete 85 Mirrors of 4 mm thick plate glass bevelled edge mirror including C.P brass revolving fittings, 3 mm plywood board and C P hinges to fix with mirrori) 600x450 mm 86 i) C.P brass towel rail 20 mm x 600 mm with bracket container 87 ii) C.P brass shop dish container medium quality with screw and hinges etc. 88 (iii) C.P brass liquid shop container 89 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 90 (a) 100 mm dia 91 (b) 80 mm dia 92 (c) 50 mm dia 93 Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design:Inside dimensions 600x 850 mm and 45 cm deep for pipe line with three or more inlets :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 94 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Singlesocketed pipes.110 mm dia 95 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Singlesocketed pipes.75 mm dia 96 Providing & supplying in standard lengths High density polyethylene pipe (HDPE pipe) confirming to IS 4984 / 14151/ 12786 / 13488 (latest revision with necessary jointing material like mechanical connector i.e., thread / insert joint / quick release coupler joint / compression fitting joints or flanged jointsecluding coupler / specials and taxes) grade PE 80-PN10 97 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 98 75 mm Coupler 99 110 mm Coupler 100 75 mm Single pushfit Coupler 101 110 mm Single pushfit Coupler 102 75 mm Single tee with door 103 110 mm Single tee with door 104 75 mm Single tee without door 105 110 mm Single tee without door 106 75 mm Bend 87.5° 107 110 mm Bend 87.5° 108 75 mm Shoe (Plain) 109 110 mm Shoe (Plain) 110 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm 111 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1KV grade of size exceeding 95 sqmm but not exceeding 185 sq mm direct in ground including excavation, sand cushioning, protective covering and refiling the trench etc as required. 112 PVC / XLPE insulated PVC sheathed heavy duty, armoured electrical cable with aluminium conductor for working voltage up to 1100 volts. (Conforms to IS : 1554, part-1) 120 sq mm, 3.5 core 113 Supplying and making cable route marker with cement concrete 1:2:4 (1cement: 2coarse sand : 4graded stone agreegate 20mm nominal size) of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickness of 10 cm including inscription duly engraved as required. 114 Providing & fixing M.V. danger notice plate of 250 mm X 150 mm, made of mild steel, at least 2mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 115 Earthing with copper plate 600mmx 600mmx 3mm thick including acessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc.(but without charcoal or cock and salt) complete etc. as required. 116 S/L 8 SWG G.I. wire in ground :- Supplying and laying 8 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including soldering etc. as required. 117 Providing & laying earth connection from earth electrode with 4mm dia copper wire in 15mm dia G.I. pipe from earth electrode, as required. 118 S/F rewireable double pole/TP&N switch disconnector:- Providing and fixing following DP/TP&N sheet metal switch disconnector fuse unit in the existing metal board with rewireable type fuses, including drilling holes in metal board. Making connection etc. as required. 119 16 amps, double pole 120 32 amps, double pole 121 63 amps, double pole 122 32 amps, TP&N 123 63 amps, TP&N 124 Providing and fixing following rating and breaking capacity MCCB with thermomagnetic release and terminal spreaders in existing cubical panel board including drilling holes in cubical panel, making connections etc. as required. 125 25 - 100 amps, 10 KVA fixed thermal setting 126 25 - 100 amps, 16 KVA fixed thermal setting 127 125 amps, 16 KVA fixed thermal setting 128 Providing and fixing following capacity bus bar chamber with 4 strips of length 300 mm made of copper suitable for following capacity complete with all accessories including connections, earthing the body etc. as required 100 amps 129 Providing and fixing following capacity 2pole / 4 pole ON / OFF - load changeover switches with side handle operation, in sheet enclosoure in existing metal board including drilling holes in metal board, making connection, earthing the body etc. as required. 130 32 amps, 2 pole 131 63 amps, 2 pole 132 Providing and fixing following ways surface / recess mounting, vertical type 415 volts, TPN MCB DB of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incommer) as required. 133 4 way ( 8 + 12 ), double door vertical type 134 8 way ( 8 + 24 ), double door vertical type 135 Supplying and fixing 6 amps to 32 amps rating, 240 volts, 10 KA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCBs DB complete with connections, testing and commissioning etc. as required. 136 6/32 amps, single pole 137 40 amps, single pole 138 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 139 Supplying and fixing following rating, four pole ( three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having sensitivity current 30 mili amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 140 16/25 amps 141 40 amps 142 Wiring for light point / fan point / exhaust fan point / call bell point with 1.5 sqmm FR PVC insulated copper conductor single core in surface / recessed PVC conduit, with modular switch, modular plate suitable GI box etc as required. 143 Group A 144 Group B 145 Group C 146 Wiring for twin control points with 1.5 sq mm FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit, 2 way with modular switch, modular plate, suitable GI box etc. as required. 147 Wiring for light/power plug with 2 X 4 sq mm FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit, along with 1 nos 4 sq mm FR PVC insulated copper conductor single for loop earthing etc as required. 148 Wiring for light/power plug with 4 X 4 sq mm FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit, along with 2 nos 4 sq mm FR PVC insulated copper conductor single for loop earthing etc as required. 149 Wiring for Circuit / sub main wiring along with earth wire with following sizes of FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit as required. 150 2 X 1.5 sq mm + 1 X 1.5 sq mm earth wire 151 2 X 2.5 sq mm + 1 X 2.5 sq mm earth wire 152 2 X 4 sq mm + 1 X 4 sq mm earth wire 153 2 X 6 sq mm + 1 X 6 sq mm earth wire 154 2 X 10 sq mm + 1 X 6 sq mm earth wire 155 Supplying and fixing stepped type electronic fan regulator on the existing modulat plate & switch box including connections but excluding modular plate etc. as required. 156 Supplying and fixing modular blanking plate & switch box excluding modular plate etc. as required. 157 Supplying and fixing following size / modules, GI boxes along with modular base & cover plate for modular switches in recess etc as required. 158 1 or 2 Module 159 4 / 5 Module 160 6 Module 161 8 / 9 Module 162 12 Module 163 Supplying and fixing suitable GI box with modular plate and cover in front on surface of in recess, including providing & fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch connection, painting etc. as required (For light plugs to be used in non residential buildings) 164 Supplying and fixing suitable GI box with modular plate and cover in front on surface of in recess, including providing & fixing 6 pin 15/16 amps modular socket outlet and 15/16 amps modular switch connection, painting etc. as required (For light plugs to be used in non residential buildings) 165 Supplying and fixing 2 pin 5 amp. Ceiling rose on the existing junction box / wooen block including connection etc. as required. 166 Supplying and fixing Batten / angle holder including connection etc. as required. 167 Supplying and fixing ding dong sound call bell single phase 230 voltscomplete as required. 168 Supplying, Installation, testing & commisioning of following size ceiling fan 3 blades confirming to IS:374:2019 including the wiring down rods of standard length up to 30 cm with 1.5 sq mm FR PVC insulated copper wire suitable for 230V 50HZ, single phase supply etc. complete as required. 1200 mm (48) 169 Installation of exhaust fan up to 450 mm sweep in the existing opening including making the hole to suit the size of the above fan making good the damage, connection, testing , commissioning etc. as required. 170 15 (450 mm ) metal exhaust fan 171 S.I.T.C. of flowing rating reccess / surface mounted LED round / Square shade down light luminaire with pressure die cast housing for single phase supply voltage. Luminaire shall be confirming to IS: 10322 part-5 / section-2 or IEC:62722 with all neccssary accessories as required. 18/20 W LED Round Down light 172 Approved make wall mounted decorative lamp with nickel / chrome finish with opal glass of lamp type E27 / E22 LED 7/9 W X 2 IS: 10322 part 5 173 S.I.T.C. of flowing rating reccess / surface mounted LED round / Square shade down light luminaire with pressure die cast housing for single phase supply voltage. Luminaire shall be confirming to IS: 10322 part-5 / section-2 or IEC:62722 with all neccssary accessories as required.90/100 W LED flood light 174 2.0 Tr 5 star split AC (inverter type) IS-1391-Part-1 175 Copper tube of size 3/8 for split ac unit1/1.5/2/3 tr capacity including nitride rubber insulation 176 Drain Pipe for AC 177 Outdoor stand for 2.0tr split AC 178 5 KVA online UPS three phase input and three phase output power system of input, voltage range 360V/380v/400v/485v AC, frequency range 40HZ-60HZ +/- 10%, output voltage range 415v +/- 1%, frequency range 50HZ +/- 1% power factor 0.8/3:1, Harmonic distortion- <2% THD(Linear load) : 5% THD (Non- linear Load) 179 MS battery rack suitable for 15-20 UPS battery installation. 180 100Ah tubular lead acid battery with 36 month replacement gurantee, IS:1652:1991 181 Trenching in ordinary soil up to a depth of 60 cm including removal and stacking of serviceable materials and then disposing of surplus soil, by spreading and neatly levelling within a lead of 50 m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or / and manure before and after flooding trench with water (excluding cost of imported earth, sludge or manure). 182 Supplying and stacking sludge at site including royalty and carriage upto 5 km complete (sludge measured in stacks will be reduced by 8% for payment). 183 Supplying and stacking at site dump manure from approved source, including carriage upto 5 km complete (manure measured in stacks will be reduced by 8% for payment) :2.4.3 Screened through sieve of I.S. designation 4.75 mm 184 Uprooting weeds from the trenched area after 10 to 15 days of its flooding with water including disposal of uprooted vegetation. 185 Spreading of sludge, dump manure and/or good earth in required thickness as per direction of officer-in-charge (cost of sludge, dump manure and/ or good earth to be paid separately). 186 Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge 187 Preparation of beds for hedging and shrubbery by excavating 60 cm deepand trenching the excavated base to a further depth of 30 cm, refilling theexcavated earth after breaking clods and mixing with sludge or manure inthe ratio of 8:1 (8 parts of stacked volume of earth after reduction by 20% : one part of stacked volume of sludge or manure after reduction by 8%),flooding with water, filling with earth if necessary, watering and finally finedressing, leveling etc. including stacking and disposal of materials declaredunserviceable and surplus earth by spreading and leveling as directed,within a lead of 50 m, lift up to 1.5 m complete (cost of sludge, manure or extra earth to be paid for separately) 188 Providing and displaying of Phoenix palm having ht. 75 cm to 90 cm with 10 to 15 or more leaves, well developed, fresh and healthy in 25 cm size of Earthen pot/Plastic pot & as per direction of the officer-in-charge. 189 Providing and stacking of Polyalthia longifolia (Ashok) of height 180-195 cm. in gunny bag of size 30 cm as per direction of the officer-in-charge. 190 Supply and stacking of plant Bauhinia tomentosa (yellow) of height 60-75 cm. in earthen pots of size 20 cm as per direction of the officer-in-charge 191 Def PRIME SRD+GG CL-C BIS KL 192 LIFEGUARDR(4 KG CLEAN AGENT TYPE FIRE EXTINGUISHER) 193 CP PLUS IP DOME CAMERA 194 CP PLUS IP BULLET CAMERA 195 32 CH NVR 200 MBPS 2 SATA 196 HARD DISK 10TB Enterprises 24*7 Surveillance (WD) PURPLE 197 HARD DISK 4TB Enterprises 24*7 Surveillance (WD) PURPLE 198 CP PLUS POE With Gigabit 199 LG Monitor 18 200 CAT6 CABLE DLINK 305 MTR (23AWG SOLID) (in Bundle) 201 D-LINK 6U RACK 202 D-LINK RJ 45 Connector (in Box) 203 Vault safe locker 204 Add 18 % GST (in Basic Rate must fill 12) 205 Add 1% Labour Cess (in Basic Rate must fill 1)

Key Value

Document Fees
INR 10000 /-
EMD
INR 135000.0 /-
Tender Value
INR 67.49 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail