}

Tender For Rate Contract For Supply Of Material Required For Day To Day Maintenance Of Split , Window Ac And Water Coolers Of Different Capacities Installed In Institutional Buildings For The Year 2024-25 In M.D.U. Rohtak, rohtak-Haryana

Boards / Undertakings / PSU has published Tender For Rate Contract For Supply Of Material Required For Day To Day Maintenance Of Split , Window Ac And Water Coolers Of Different Capacities Installed In Institutional Buildings For The Year 2024-25 In M.D.U. Rohtak. Submission Date for this Tender is 22-08-2024. Wrenches and Drivers Tenders in rohtak Haryana. Bidders can get complete Tender details and download the document.




Tender Notice

44530716
Tender For Rate Contract For Supply Of Material Required For Day To Day Maintenance Of Split , Window Ac And Water Coolers Of Different Capacities Installed In Institutional Buildings For The Year 2024-25 In M.D.U. Rohtak
Open Tender
Indian
Haryana
Rohtak
22-08-2024

Tender Details

Tender For Rate Contract For Supply Of Material Required For Day To Day Maintenance Of Split , Window Ac And Water Coolers Of Different Capacities Installed In Institutional Buildings For The Year 2024-25 In M.D.U. Rohtak-- 1 Capacitor 1.5 Mfd MakeEpcos/ GC/ Tibcon 2 Capacitor 4 Mfd MakeEpcos/ GC/ Tibcon 3 Capacitor 6 Mfd MakeEpcos/ GC/ Tibcon 4 Running capacitor Aluminium cap 36 Mfd. Epcos/ GC/ Tibcon make 5 Running capacitor Aluminium cap 45 Mfd. Epcos/ GC/ Tibcon make 6 Running capacitor Aluminium cap 45+6 Mfd. Epcos/ GC/ Tibcon make 7 Running capacitor Aluminium cap 50 Mfd. Epcos/ GC/ Tibcon make 8 Running capacitor Aluminium cap 50+6 Mfd. Epcos/ GC/ Tibcon make 9 Running capacitor Aluminium cap 60 Mfd. Epcos/ GC/ Tibcon make 10 Running capacitor Aluminium cap 60+6 Mfd. Epcos/ GC/ Tibcon make 11 Starting capacitor Aluminium cap 100-120 Mfd. Epcos/ GC/ Tibcon make 12 New fan motor for window AC 1.5 ton copper wound make and model as per existing installed AC with one year guarantee. 13 New fan motor for window AC 2.0 ton copper wound make and model as per existing installed AC with one year guarantee. 14 New fan motor Outdoor for Split AC 1.5 ton copper wound make and model as per existing installed AC with one year guarantee. 15 New fan motor Outdoor for Split AC 2.0 ton copper wound make and model as per existing installed AC with one year guarantee. 16 Bearing for AC fan motor ‘NBC’ / ‘SKF’ make as per requirement of existing installed AC. 17 Connector 32 Amp for AC voltage stabilizer three pin in bakelite. 18 Copper pipe heavy 1/4” ‘Mandev’ make. 19 Copper pipe heavy1/2” ‘Mandev’ make 20 Copper pipe heavy 3/8” ‘Mandev’ make 21 Copper pipe heavy 5/8” ‘Mandev’ make 22 Insulation rubber pipe for covering for copper pipe 5/8 ‘Malayasia’ make 23 Dead nut for Suction Valve brass ¼” 24 Dead nutfor Discharge Valve brasbrass 1/2” 25 Dead nutfor Suction Valve brasbrass 5/8” 26 Flair nut brass 1/4” 27 Flair nut brass 1/2” 28 Flair nut brass 3/8” 29 Flair nut brass 5/8” 30 Silver coated Copper thimble 32 Amp (100 piece in one Pkt.) 31 Fan blower for Window AC 1.5 make and model as per requirement of existing installed AC. 32 Fan blower for Window AC 2.0 ton make and model as per requirement of existing installed AC. 33 Fan Blade for Window AC 1.5 make and model as per requirement of existing installed AC. 34 Fan Blade for Window AC 2.0 ton make and model as per requirement of existing installed AC. 35 Fan blower for Split AC indoor 1.5 ton make and model as per requirement of existing installed AC. 36 Fan blower for Split AC indoor 2.0 ton make and model as per requirement of existing installed AC. 37 Fan blade Split AC 1.5 Ton Outdoor, make and Model, as per requirement of existing installed AC. 38 Fan blade Split AC 2.0 Ton Outdoor, make and Model, as per requirement of existing installed AC. 39 Capilary Pipe Copper Size 55 No. 40 Capilary Pipe Copper Size 60 No. 41 Filter Copper 2 Way 42 Filter Copper 3 Way 43 Pencil valve Copper 1/4 44 Brass Valve 1/4” brass 45 Brass Valve 3/8” brass 46 Brass Valve 1/2” brass 47 Brass Valve 5/8” brass 48 Copper cooling coilBlue Fins for window AC 1.5 ton as per requirement of existing installed AC. 49 Copper cooling coil Blue Fins for window AC 2.0 ton as per requirement of existing installed AC. 50 Copper cooling coil Blue Fins for split AC 1.5 ton as per requirement of existing installed AC. 51 Copper cooling coil Blue Fins for split AC 2.0 ton as per requirement of existing installed AC. 52 Copper condenser coil Blue Fins for split AC 1.5 ton outdoor unit as per requirement of existing installed AC. 53 Copper condenser coil Blue Fins for split AC 2.0 ton outdoor unit as per requirement of existing installed AC. 54 Coil Sensor. Make and model as per existing installed AC 55 Temperature Sensor. Make and model as per existing installed AC 56 New PCB for indoor split AC 1.5 ton with Display and Remote as per requirement of existing installed AC. 57 New PCB for indoor split AC 2.0 ton with Display and Remotet as per requirement of existing installed AC. 58 New PCB for Window AC 1.5 ton with Display and Remote as per requirement of existing installed AC. 59 New PCB for Window AC 2.0 ton with Display and Remotet as per requirement of existing installed AC. 60 New PCB for Inverter Indoor Split AC 1.5 ton with Display and Remote as per requirement of existing installed AC. 61 New PCB for Inverter Indoor Split AC 2.0 ton with Display and Remote as per requirement of existing installed AC. 62 New PCB for Inverter Outdoor Split AC 1.5 ton with Display and Remote as per requirement of existing installed AC. 63 New PCB for Inverter Outdoor Split AC 2.0 ton with Display and Remote as per requirement of existing installed AC. 64 New PCB for Inverter Outdoor Split AC 1.5 ton(Hot and Cold) with Display and Remote as per requirement of existing installed AC. 65 New PCB for Inverter Outdoor Split AC 2.0 ton(Hot and Cold) with Display and Remote as per requirement of existing installed AC. 66 New compressor rotary 1.5 ton GMCC/ ‘Highly’ / ‘Hitachi’’ make with one year guarantee. 67 New compressor rotary 2.0 ton GMCC/‘Highly’ / ‘Hitachi’ make with one year guarantee. 68 New compressor rotary 1.5 ton Scroll make with one year guarantee. 69 New compressor rotary 2.0 ton Scroll make with one year guarantee. 70 New compressor 1.5 ton invertor AC make as per requirement. 71 Newcompressor 2 ton invertor AC make as per requirement. 72 Refilling of R22 gas Mafron, Floron make in existing cylinder provided by the department. 73 Refilling of R32 gas Mafron, Floron make in existing cylinder provided by the department. 74 Refilling of R410 gas Mafron, Floron make in existing cylinder provided by the department. 75 Refilling of Nitrogen gas in existing cylinder provided by the department.(capacity of existing cylinder is 7 cubic meter) 76 Refilling of Oxygen gas in existing cylinder provided by the department.(capacity of existing cylinder is 7 cubic meter) 77 New DC fan motor for window AC 1.5/2.0 ton copper wound make and model as per existing installed AC with one year guarantee. 78 New DC fan motor for split ACindoor 1.5/2.0 ton copper wound make and model as per existing installed AC with one year guarantee. 79 New DC fan motor for split AC Outdoor 1.5/2.0 ton copper wound make and model as per existing installed AC with one year guarantee. 80 PVC Drain tray for Window AC 19x22x27 81 Split AC Outdoor Safety Guard 2x2 82 LPG can portable gas cartridge 83 Packing tape 2 size (50 Meter per roll) 84 Drain pipe PVC Flexible (Length6 Feet Each) 85 Drain pipe PVC 25 mm Dia. Length 10 Foot) Make - Prince 86 PVC 25 mm (1) Saddle with 2 Nails 87 PVC 25 mm Tee (1)(Make -Prince) 88 PVC 25 mm Elbow (1) (Make -Prince) 89 PVC Drain Pipe for Indoor Split AC (1.5 Foot) 90 Teflon TapeMake -3M 91 Fevi Bond Tube 92 Steel Screw for Window AC/ Split AC Outdoor 93 Rubber gutka and rubber ring / rubber ring iron clamp model as per requirement for holding fan motor (12+12+12 ) 94 Rubber gutka, rubber ring and Stud for 1.5 Ton/2.0 Ton Compressor for window/ Split AC model as per requirement. 95 Fan Motor Bush ofGun Metal and Shaft of Steel 96 Welding Rod Copper 97 3 Pin Top 16 Amp. 98 AC Plug and Socket Metal Clad Protected 20 Amp 2 Pole (Plug and Socket Set) 99 SPN 40 Amp. Make L &T/Havells/Indoasian 100 TPN 63 Amp. Make L &T/Havells/Indoasian 101 TP 63 Amp. Make L &T/Havells/Indoasian 102 25 Amp Contactor Single Phase Make : L & T 103 Cap Case Batton 50 mm50 mm X 1.5 mm x 2 m Make Precision (L= 6 Feet) 104 PVC Gitti 6 mm. (50 Pcs per Pkt.) 105 Black Screw 1.5 106 Split AC Outdoor Stand 107 Fastener for Split AC Outdoor 8 mm 108 Four Core Wire 2.5 mm. (90 Meter) Make: Havells 109 Single Core 2.5 mm (90 Meter) Make: Havells 110 Remote for existing 1.5 / 2.0 ton window / split AC make ‘Blue Star’ / ‘Hitachi’ / ‘Voltas’ / .Samsung’ 111 M Seal (1 Kg, Each Packet) 112 Cable Tie 75 mm 113 Pencil Cell Type: AAA Make: Duracell 114 PVC TapeMake- Steelgrip,Anchor, Girish 115 New compressor reciprocating 1.1 ton Kirlosker, ‘copeland’ Make with one year guarantee. Old scrapcompressor should not be retained by department. So rates will be quoted by discounting the cost of old compressor. Model No. KCG-513 116 Refilling of R22 gas Mafron, Floron make in existing cylinder provided by the department. 117 R 134 A Gas Mafron, Floron make in existing cylinder provided by the department. 118 Thermostat Copper Make Godrej, Anapurna 119 Capilary Pipe Copper Size 50 No. 120 Filter Copper 3 Way MakeVijay 121 Running capacitor Aluminium cap 45 Mfd. Epcos/ GC/ Tibcon make 122 Running capacitor Aluminium cap 36 Mfd. Epcos/ GC/ Tibcon make 123 Capacitor 4 Mfd MakeEpcos/ GC/ Tibcon 124 Starting capacitor Aluminium cap 100-120 Mfd. Epcos/ GC/ Tibcon make 125 Box Type Relay32 Amp. 126 New fan motor for water cooler 150 Ltrs. copper wound make and model as per existing installedwater cooler with one year guarantee.Old scrap of Motor should not be retained by department. So rates will be quoted by discounting the cost of old Motor. 127 Fan Blade Aluminium 128 Welding Rod Copper 129 LPG can portable gas cartridge 130 Fan Motorrubber ring 131 Fan Motor stand 132 Copper condenser coilfor water cooler 150 Ltrs.as per requirement of existing installed water cooler. Old scrap Coil should not be retained by department. So rates will be quoted by discounting the cost of old condenser coil. 133 Copper pipe heavy 1/4” ‘Mandev’ make. 134 Copper pipe heavy1/2” ‘Mandev’ make 135 Copper pipe heavy 3/8” ‘Mandev’ make 136 Silver coated Copper thimble 32 Amp (100 piece in one Pkt.) 137 Steel Screw for water cooler body 138 Cable Tie 75 mm 139 Drain pipe PVC Flexible of 1.25 Dia. (Length6 Feet Each) 140 Drain Pipe Ring (Dia-1.25) 141 3 Core x 2.5 mm sq copper cable (100 Mtr.) 142 Refilling of Nitrogen gas in existing cylinder provided by the department.(capacity of existing cylinder is 7 cubic meter) 143 Refilling of Oxygen gas in existing cylinder provided by the department.(capacity of existing cylinder is 7 cubic meter) 144 Pencil valve Copper 1/4 145 PVC TapeMake- Steelgrip,Anchor, Girish

Key Value

Document Fees
INR 1000 /-
EMD
INR 37540.0 /-
Tender Value
INR 18.77 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail