}

Tender For Annual Maintenance Of 11Kv Substation Equipment And Associated Works In Anupuram Township For The Year 2024 - 2025., Chengalpattu-Tamil Nadu

Government Departments has published Tender For Annual Maintenance Of 11Kv Substation Equipment And Associated Works In Anupuram Township For The Year 2024 - 2025.. Submission Date for this Tender is 26-08-2024. Tanks and Cylinders Tenders in Chengalpattu Tamil Nadu. Bidders can get complete Tender details and download the document.




Tender Notice

44490154
Corrigendum : Tender For Annual Maintenance Of 11Kv Substation Equipment And Associated Works In Anupuram Township For The Year 2024 - 2025.
Open Tender
Indian
Tamil Nadu
Chengalpattu
26-08-2024

Tender Details

Annual Maintenance Of 11Kv Substation Equipment And Associated Works In Anupuram Township For The Year 2024 - 2025. Annual Maintenance Of 11Kv Substation Equipment; 1 Maintenance of following 11 kV Panel as per detailed Specification and as directed by Engineer-in-charge 2 Cubical Switchboards having number of vertical sections upto 8. 3 Cubical Switchboards having number of vertical sections more than 8 and upto 12. 4 Cubical Switchboards having number of vertical sections more than 12 and upto 16. 5 Cubical Switchboards having number of vertical sections upto 2 6 Maintenance of following 11 KV Circuit Breaker as per detailed specification and as directed by the Engineer-In-Charge. 7 Maintenance of 11kV, Vacuum Circuit Breaker 8 Vacuum integrity test for 11kV Vacuum Circuit Breaker 9 Testing of all types of Numerical and Electromagnetic protection relays using 3Phase Current injecting calibration kit, as per the detailed specification and as directed by the Engineer-in-Charge. 10 Maintenance of following 11 kV / 433Volts Distribution Transformer as per detailed Specification and as directed by Engineer-in-charge 11 Distribution Transformer of capacity 500 kVA to 7 MVA (Refer Sec VI (MNC), Clause No.18.1). 12 Distribution Transformer of capacity 250 kVA upto 400 KVA (Refer Sec VI (MNC), Clause No.18.1). 13 Overhauling and Maintenance of Distribution Transformer at Site, including draining of oil, opening of transformer top cover, supply, replacement of all gaskets, oil seals, O rings, Oil filtration, arrangement of all required special tools & equipments as per the detailed specification and as directed by the Engineer-in-Charge. 14 11KV/433V Upto 500KVA, ONAN, DistributionTransformer 15 11KV/433V above 500kVA and upto 1500KVA, ONAN, DistributionTransformer 16 Supply and replacement of 1 Kg Silicagel breather container made out of Aluminium top and bottom, transparent tubular container with clear view oil cup including silicagel and necessary coupling arrangementas per the detailed specification and as directed by the Engineer in Charge. 17 Supply and replacement of Silicagel in Breathers of Transformers/Bus ducts/Storage Tanks as per the detailed Specification and as directed by the Engineer-in-charge. 18 Reconditioning of Silicagel in Breathers of working Transformers and Bus ducts (Refer Sec VI (MNC), Clause No.20). 19 Transformer oil sample collection at site, Transporting to NABL Accredited testing laboratory, Carrying out the tests mentioned as per the detailed Specification, submission of test reports and as directed by Engineer-in-charge. 20 Collection of Transformer oil samples and Conducting Break Down Voltage test at Site. (Refer Sec VI (MNC), Clause No.20.3). 21 Collection of Transformer Oil in 20 litre container from sub-store electrical, transportation to various substations within a range of up to3kms and topping up of into the Transformers as per the detailed Specification and as directed by the Engineer-in-Charge. (Oil will be issued as a free issue item by the Department) 22 Operation of filtration plant for Reconditioning of Transformer oil in Transformers / storage Tank / Drums. (Refer Sec VI (MNC), Clause No. 20.1). 23 Maintenance of 415 Volts Power control centres / LT panels, Busducts, TPN switch Fuse Units and ACBs (Refer Sec VI (MNC), Clause No.17.2). 24 415 Volts PCC Panel consisting of3 Nos of ACBs and Cubical Switchboards having number of vertical sections upto 10. 25 415 Volts PCC Panel consisting of5 Nos of ACBs and Cubical Switchboards having number of vertical sections upto 6. 26 415 Volts PCC Panel consisting of10 Nos ACBs, Cubical Switchboards having number of vertical sections upto 10 and 2 Nos Bus Ducts. 27 415 Volts PCC Panel consisting of7 Nos ACBs, Cubical Switchboards having number of vertical sections upto 10 and 2 Nos Bus Ducts. 28 415 Volts PCC Panel of Tower Blocks consisting of 3 Nos of ACBs and Cubical Switchboards having number of vertical sections upto 4. 29 Maintenance of 415 Volts Distribution Centres, LT panels / TPN switch Fuse Units (Refer Sec VI (MNC), Clause No.17.2). 30 Cubicle switch boards having number of vertical sections up to 3 31 Cubicle switch boards having number of vertical sections more than 3 32 Maintenance of 415 Volts DG AMF Panel as per detailed Specification.(Refer Sec VI (MNC), Clause No.17.2). 33 380 kVA, AMF Panel with 2 Nos ACBs and Cubical Switchboards having number of vertical sections upto 5. 34 180 / 250 kVA AMF Panel with 2 Nos Contactors and Cubical Switchboards having number of vertical sections upto 5. 35 Maintenance of 415 Volts Feeder Pillar (Refer Sec VI (MNC), Clause No.17.2). 36 Maintenance of Feeder Pillar (Type-A) 37 Maintenance of Feeder Pillar (Type-B) 38 Top up of Diesel to the DG Set diesel tanks using the available empty Diesel drums (200 Ltr capacity) including transportation of empty drums to the fuel filling station (Petrol bunk), filling diesel to the empty drums and toping up the same to the diesel tanks of the DG sets, located at various places within the range of 10 kms inside the Township as per specification and as directed by the Engineer-in Charge. 39 Maintenance of 2.2 kVA Portable Genset as per the detailed specification and as directed by Engineer-in-charge 40 Supply, replacement of 12 Volts, Heavy duty DG Starting Batteries including supply of 2 Nos Copper terminal clamps and Installation, Testing as per the detailed specification and as directed by Engineer-in-charge 41 Maintenance of Batteries, Battery banks & Battery Charger etc., 42 Curative discharge and charge on VRLA Battery Banks of voltage more than 48 V & up to 110 V. (Including hourly recording of all cell voltages) (Refer Section VI (MNC), Clause No. 8.0.) 43 Maintenance of Battery chargersas per the detailed specification and as directed by the Engineer-In-Charge. (Refer Sec VI (MNC), Clause No. 8.0). 44 Maintenance of Lead Acid Batteries including Supply of distilled water and top up, cleaning and recording of readings as per detailed Specification. 45 Maintenance of 110 Volt, VRLA type sealed maintenance free Lead Acid Battery bank as per the detailed specification. 46 Supply, Replacement of Panel board components including removal of faulty components, as per the detailed specification and as directed by the Engineer-in-Charge. 47 Panel LED Indication Lamp Dia 22.5 mm, of colour Red / Yellow / Green / Amber suitable for operating to 24V to 240V AC/DC. 48 Panel LED Indication Lamp Dia 22.5 mm, of colour Blue / White suitable for operating to 24V to 240V AC/DC. 49 Providing set of 3 Nos of LED Indication lamp (Red, Yellow, Blue) with inscription plate on lamp, required 1.5 Sq.mm FRLS Copper wire, Din rail and copper lugs etc, as per the detailed specification. 50 230Volts, 60 / 80 watts Panel mounting Space Heater. 51 Thermostat 25-85 deg suitable for panel mounting 52 Panel door lock suitable for existing panel door. 53 Supply, installation, testing and commissioning of the following SDFU with factory made enclosure with 3Nos Fuse links on MS frame work as per the scope of work. (MS item will be measured separately). (Refer Sec VI, Clause No.14.1). 54 SDFU TPN 63A, DIN FUSES with 3Nos 63A HRC fuse links, Sheet steel enclosure FN Cat No:SK90484 55 SDFU TPN 125A, DIN FUSES with 3Nos 125A HRC fuse links, Open Execution FN Sheet steel enclosure FN Cat No:SK90486 56 SDFU TPN 250A, DIN FUSES with 3Nos 250A HRC fuse links, Sheet steel enclosure FN Cat No:SK90489 57 Supply, installation, testing and commissioning of the following manual on load Change over Switch - disconnector with factory made sheet steel enclosure mounted on MS frame work as per the scope of work. (MS item will be measured separately). 58 FP 63A, 415V, AC 23A mounted in a Sheet steel enclosure 59 FP 125A, 415V, AC 23A mounted in a Sheet steel enclosure 60 FP 250A, 415V, AC 23A mounted in a Sheet steel enclosure 61 Replacement of 415 Volts SDFU/MCCBs in the existing LT Panel, including removal of existing SDFU/MCCB, suitable modification of Aluminium busbars, fasteners, FRPpartitioning, Testing and Commissioning as per the detailed specification. Note: Requied 415 Volts SDFU / MCCB will be supplied by department as Free Issue, all other consumables will be supply and installation. 62 400/250 Amps TPN/4 Pole SDFU/MCCBs 63 125/63 Amps TPN/4 Pole SDFU/MCCBs 64 Supply, replacement of following components including removal of existing components etc. as per the detailed specification and as directed by Engineer-in-charge. 65 2 - 20 Amps, HRC Fuse Links Type HG Offset Staggered 66 Push Button Flush Head, (Green/Black/Yellow/White/ Blue/Orange) with 2 Nos Auxiliary block. 67 Push Button Mushroom Head (Push Turn, Colour Red, Cat.No: HH55C1) with 2 Nos Auxiliary block. 68 Cleaning of Electrical equipments, utilities, LT Panels, trenches, surfaces, floors, roof tops, various rooms / bays,premises, etc. in and around various Sub-Stations and Feeder Pillars as per the detailed specification. 69 Switchgear Room Size upto:50 Sq.mtr, including HT Panel , LT Panel etc. 70 Switchgear Room Size upto:100 Sq.mtr, including HT Panel , LT Panel, Battery charger etc. 71 Switchgear Room Size upto:200 Sq.mtr, including HT Panel , LT Panel, Battery charger etc. 72 Transformer Bays of size: upto 25 Sq.mtr, including Transformer. 73 Transformer Bays of size: upto 50 Sq.mtr, including Transformer. 74 DG rooms of size upto 70 Sq.mtr, including DG Sets, AMF Panels and Street light control panel. 75 Auxiliary Distribution Panel room of size Up to 50 Sq.mtr including Distribution panel. 76 Cleaning of Indoor Cable trenches upto 1.2 mtrwidth (Refer Sec VI (MNC), Clause No.26). 77 Substation Switchgear room floor cleaning & Moping. 78 Feeder Pillar room upto 3 Sq.mtr, all around Feeder Pillar 5 Sq.mtr, all around Earth pit 4 Sq.mtr and cleaning of Feeder pillar. 79 Surveillance visit for Switchgear rooms, Transformer bays and DG rooms etc., including recording load parameters, abnormalities, etc., as per the detailed specification and as directed by the Engineer-In-Charge. 80 Maintenance of Earth Pits including supply of Sodium Bentonite, and measurement of Earth Pit Resistance as per the specification and as directed by the Engineer in Charge. (Refer Sec VI (MNC), Clause No.2). 81 Maintenance of Earth Pits and measurement of Earth Pit Resistance as per the specification. (Refer Sec VI (MNC), Clause No.2). 82 Demolition of Earth Pit chamber, transporting and storage of masonry debris in specific location with a maximum lead of 3 Kms. approximately including excavation and re-filling and as directed by Engineer-in-charge. 83 Supply and replacing following earth pit chamber parts after removing and disposing off old/damaged part as per drawing No. IGC/ESD/5060/1008/1.(Refer Sec VI (MNC), Clause No.2.0). 84 RCC Top Cover alone 85 RCC Ring Collar alone 86 RCC Ring with Cover 87 Supply and replacing of RCC Cable Identification marker for HT Cable / LT Cable / Cable Joint as per drawing and inscription as directed by Engineer-in-Charge and as per detailed specification. 88 Supply and installation of 8 SWG copper wires in built in trench as per the detailed specification.(Refer Sec VI, Clause No.12.8) 89 Supply and replacement of 7/11 SWG (7 strand 11SWG) G.I Stay wire on HT Structures and Poles of 11KV Feeder No. 1 and 2, including removal of existing stay wire, fasteners etc., as per detailed specification and as directed by the Engineer-in-Charge. 90 Cleaning and water washing of Solar Photo Voltaic Panel, cleaning with solvent and removal of vegetation growth, dry leaves all around the Solar PV panel system as per the detailed specification. 91 Removal of existing blue metal stones from the transformer bay, cleaning using suitable oil removing agent followed by water washing, drying and refilling back into the transformer bay as per the detailed Specification and as directed by the Engineer-in-Charge 92 Supply and Painting with One coat of Synthetic enamel paint on metallic surfaces of electrical equipments, and other required surface at all levels with primer and following paint (Asian or approved brand, colour and manufacturer) to give an even shade including preparation of the surfaces, scaffolding complete all as per specifications and as directed by the Engineer-in-Charge. (Refer Sec VI (MNC), Clause No.3). 93 Painting of 415V Switchboards with Two coats of synthetic enamel Paint including supply of paints and required consumables (Refer Sec VI (MNC), Clause No.3). 94 Cubicle switch boards having number of vertical sections upto 3 (Refer Sec VI (MNC), Clause No.3) 95 Cubicle switch boards having number of vertical sections above 3 and up to 6 (Refer Sec VI (MNC), Clause No.3). 96 Cubicle switch boards having number of vertical sections above 6 (Refer Sec VI (MNC), Clause No.3). 97 Painting of Distribution Equipments with ONE Coat of Primer, TWO Coat of Synthetic Enamel Paint including supply of paint & primer and required consumables .(Refer Sec VI (MNC), Clause No.3). 98 Upto 750 kVA Transformer 99 Above 750 kVA and upto 1500 kVA Transformer 100 Feeder Pillars - Type - A 101 Feeder Pillars - Type-B 102 Lettering the Substation/Feeder pillar etc., in following size and shape with synthetic enamel paint of different background colours, letter colour & size of letter as directed by Engineer in Charge. (Refer Sec VI (MNC), Clause No.10.3). 103 With in 200 mm dia/ (225x100mm area) Single letter of approved font and colour. (Measurement shall be paid for each letter as 1 No). 104 300 mm size single letter of approved font and colour. (Measurement shall be paid for each letter as 1 No). 105 Lettering on electrical equipments with in the area of 500 x 100mm without background colour, multiple letters, size and colour as directed by Engineer in Charge. (Refer Sec VI (MNC), Clause No.10.3). 106 Supply and Installation of following general electrical items as per the detailed specification (Refer Sec VI (MNC), Clause No.5). 107 water proof stickers of 250 x 50 mm size with messages as directed by Engineer in charge 108 Supply and Installation of MS Brackets, Supports, Frame work, Clamps, Base Channels, etc. fabricated out of angle / Channel / Rods etc. The rate quoted shall include the cost of fabrication / welding, cleaning and painting/ galvanising as follows including supply of required, fasteners, nuts, washers, etc.(Refer Sec VI, Clause No.11). 109 MS fabrication 1 coat primer & 2 coats synthetic enamel paint. 110 Labour charges for cleaning the existing sunshade tops, roof terraces, canopy / sunshade tops in staircases by removing the unwanted materials, debris and dry leaves etc., including removing the vegetation growth along with roots, applying suitable chemicals, plugging the holes using CM 1:3, collecting and disposing the waste materials by suitable means at places shown within 2 KM lead all as directed by Engineer-in-charge. 111 Non-Residential buildings 112 Clearing light jungle area, bulb weeds, grass including removal all unwanted plants, branches, twigs, wild growth etc. Complete, and disposing the same 100 meters away manually or burning them without disturbing other areas etc., complete all as directed by the Engineer-in-Charge. Contractor must inform the Engineer-in-charge and prior permission shall be obtained from him for burning the wild growth. (Refer Sec VI (MNC), Clause No.7.3). 113 Trimming Tree Branches near & around the Street Light Luminaries / ABC Spun Poles including disposal of removed branches to location within 3 kms,as specified by Engineer-in-Charge. Each street light pole will be considered as 1 No. for measurement. (Refer Sec VI (MNC), Clause No.7.1). 114 Annual Maintenance work (12 Visit per year), and Rectification of repair worksin the Dump waiter at panchasharam guest building as per the detailed specification and as directed by the Engineer-in-Charge. 115 Carrying out Tap changing operations in distribution Transformer including measurement of winding resistance before and after tap changing as per detailed Specification and as directed by the Engineer-In-Charge. 116 Carrying out Breakdown Maintenance /Trouble shouting /Renovation & Modification works in 11 kV / 415 V Distribution System as per detailed Specification and as directed by the Engineer-In-Charge. 117 Shifting of following Heavy Electrical equipment including safe loading, transportation and unloading. (Refer Sec VI (MNC), Clause No.31). 118 Equipment weighing upto 100 kgs within a distance of 500 meters 119 Equipment weighing upto 100 kgs for a distance more than 500 meters and upto a distance of 5 kms 120 Equipment weighing more than 100 kgs and upto 500 kg within a distance of 500 mtrs. 121 Heavy Electrical equipment (more than 500 kgs and upto 5 Tons) within a distance of 1 kms 122 Heavy Electrical equipment (more than 500 kg and upto 5 Tons) within a distance of 5 kms. 123 Shifting of oil filtering machine/transformers of capacity more than 100 kVA within a distance of 500 m. 124 Shifting of oil filtering machine/transformers of capacity more than 100 kVA distance of more than 500m and upto 5Km. 125 Supply, replacement of Rewireable Porcelain Fuse Unit complete set in the existing feeder pillar as per the detailed specificationand as directed by the Engineer in Charge. 126 415 Volts, 63Amps 127 415 Volts, 100Amps 128 Loading, Transportation, Unloading at site, installation, Testing and Commissioning of one number PVC/HRPVC/XLPE insulated, PVC sheathed armoured power cable of 11kV grade, the following sizes of cable direct in ground including excavation, sand cushioning, protective covering, with two sides with chamber burnt/cement brick & top PCC slab, RCC route marker and refilling the trench etc as required. (Note: Cable will be issued free of cost by the department). (Refer Sec VI, Clause No.3) 129 Above 3C x 120 sq.mm but not exceeding 3C x 240 sq mm 130 Loading, Transportation, Unloading at site, installation, Testing and Commissioning of 11kVolts Grade XLPE/HRPVC insulated, Stranded Aluminium conductor cables of following sizes in built-in trenches, on walls, poles and through embedded pipes including supply of GI spacer, clamps etc and as per the detailed specification (Note: Cable will be issued free of cost by the department).(Refer Sec VI, Clause No.3) 131 3 Core X above 120 to up to 240 Sq.mm 132 Loading, Transportation, Unloading at site, Laying, Testing and Commissioning of one number PVC/HRPVC/XLPE insulated and PVC sheathed Stranded Aluminium/copper conductor power cable of 1.1 KV grade of following sizes direct in ground including excavation, sand cushioning, protective covering with chamber burnt/cement bricks on sides & top, refilling the trench and providing RCC route indicator etc as required (Note: Cable will be issued free of cost by the department).(Refer Sec VI, Clause No.3) 133 3/3.5/4 Core X upto 25 Sq.mm 134 3/3.5/4 Core X above 25 to 3/3.5/4 Core X up to 120 Sq.mm 135 3/3.5/4CX Above 120 Sq.mm but not exceeding 3.5/4CX 240 Sq.mm 136 3/3.5/4 Core X Above 240 Sq.mm to 3/3.5/4Core X 400 Sq.mm 137 Loading, Transportation, Unloading at site, installation, Testing and Commissioning of 1100 Volts Grade PVC/HRPVC/XLPE insulated, Stranded Aluminium/copper conductor cables of following sizes in built-in trenches, on walls, poles and through embedded pipes including supply of GI spacer, clamps etc and as per the detailed specification (Note: Cable will be issued free of cost by the department).(Refer Sec VI, Clause No.3) 138 3/3.5/4core X Upto 25 Sq.mm 139 3/3.5/4Core X above 25 & up to 120 Sq.mm 140 3/3.5/4Core X above 120 & up to 240 Sq.mm 141 3/3.5/4Core X above 240 & up to 400 Sq.mm 142 Retrieval of the already laid one number PVC/HRPVC/XLPE insulated and PVC sheathed power cable of 11 KV grade of following sizes laid direct in ground including retrieval of end termination, excavation of trenches, retrieving of bricks, back filling and Re - laying the same cable direct in ground by using retrieved bricks including transportation of cables, excavation and backfilling of soil, supply of sand, shortage bricks etc as per the detailed specification. (Refer Sec VI, Clause No.7) 143 3 Core Above 120 & Upto 240 Sq.mm 144 Retrieval of the already laid one number 11kV (E), 3 Core, Aluminium Conductor, XLPE insulated Power cables of following sizes in built-in trenches, on walls, poles and from embedded pipes including removal of GI spacer, clamps etc and relaying the same cable in built-in trenches, on walls, poles and through embedded pipes using the retrieved Spacer & clamp & supplying the shortage Spacer & clamp if any as per the detailed specification. (Refer Sec VI, Clause No.7) 145 3 Core Above 120 & upto 240 Sq.mm 146 Retrieval of the already laid one number PVC/HRPVC/XLPE insulated and PVC sheathed power cable of 1.1 KV grade of following sizes laid direct in ground including removal of end termination, excavation of trenches, retrieving of bricks, back filling and Re - laying the same cable direct in ground by using retrieved bricks including transportation of cables, excavation and backfilling of soil, supply of sand & shortage bricks etc as per the detailed specification. (Refer Sec VI, Clause No.7) 147 3/3.5/4 Core upto 25 sq.mm 148 3/3.5/4 Core Above 25sqmm & upto120 Sq.mm 149 3/3.5/4 Core Above 120sqmm & upto 240 Sq.mm 150 3/3.5/4 Core Above 240sqmm & upto 400 Sq.mm 151 Retrieval of the already laid one number 1100 Volts Grade XLPE/HRPVC insulated, Stranded Aluminium conductor cables of following sizes in built-in trenches, on walls, poles and from embedded pipes including removal of GI spacer, clamps etc and relaying the same cable in built-in trenches, on walls, poles and through embedded pipes using the retrieved spacer & clamp & supplying the shortage spacer & clamp if any as per the detailed specification. (Refer Sec VI, Clause No.7) 152 Upto 3/3.5/4 C X 25 Sq.mm 153 3/3.5/4 Core Above 25 & upto 120 Sq.mm 154 3/3.5/4 Core Above 120 & upto 240 Sq.mm 155 3/3.5/4 Core Above 240 & upto 400 Sq.mm 156 End Termination of the following sizes of Aluminium Conductor PVC Insulated and sheathed armoured UG Cable using Single Compression, Heavy Duty, Gland connecting the cable to the equipment such as Switches/Panel Boards etc. using Comet or equivalent make Aluminium crimping lugs as directed by Engineer-in-Charge. The rate shall include the cost of supply of Cable Gland and Lugs. The Contractor shall arrange for making holes wherever necessary for fixing cable gland. (Refer Sec VI, Clause No.10.1). 157 4 C X 10 Sq.mm 158 4 C X 16 Sq.mm 159 3.5 C / 4 C x 25 Sq.mm 160 3.5 C / 4 C x 35 Sq.mm 161 3.5/4C x 50/70 Sq.mm 162 3.5 C x 95 / 120 Sq.mm 163 3.5 C x 185 Sq.mm 164 3.5 x 240 sq.mm 165 3.5 x 400 Sq.mm 166 Removal of termination of armoured cables of following sizes from electrical equipment or reconnecting of removed termination as per the detailed specification and as directed by Engineer-in-Charge. 167 Sizes upto 4C X 25 Sq.mm (Refer Sec VI, (MNC), Clause No.27.0) 168 Sizes above 3.5/4C X 25 Sq.mm and upto 3.5/4C X 70 Sq.mm. (Refer Sec VI, (MNC), Clause No.27.0) 169 Sizes above 3.5/4C X 70 Sq.mm and upto 3.5/4C X 95/120 Sq.mm 170 Sizes above 3.5/4C X 120 Sq.mm and upto 3.5/4C X 185 Sq.mm 171 Sizes above 3.5/4C X 185 Sq.mm and upto 3.5/4C X 240 Sq.mm 172 Sizes above 3.5/4C X 240 Sq.mm and upto 3.5/4C X 400 Sq.mm 173 Assisting in cable straight through or transition jointing of following size of cables by providing minor excavation, transportation of gas cylinder, jointing materials & tools, dressing the cable wherever required after job completion etc as per site condition and as directed by the Engineer-in-charge. (Refer Sec VI, Clause No.10.4) 174 Voltage grade upto 1.1 kV & size upto 120 Sq.mm 175 Voltage grade upto 1.1 kV of size exceeding 120 Sq.mm and upto 240 Sq.mm 176 Voltage grade upto 1.1 kV of size exceeding 240 Sq.mm and upto 400 Sq.mm 177 Assisting in cable straight through or transition jointing of following size of cables by providing temporary shelter, minor excavation, transportation of gas cylinder, jointing materials & tools, dressing the cable wherever required after job completion etc as per site condition and as directed by the Engineer-in-charge. (Refer Sec VI, Clause No.10.4) 178 Voltage grade upto 11 kV of size exceeding 120 Sq.mm and upto 240 Sq.mm 179 Supply, installation, testing and commissioning of the following Raychem make Heat Shrinkable Cable Straight Through Jointing Kits (Crimping type) for 3.5 Core Aluminium Conductor, 1.1 kV (E), PVC/XLPE insulated cables of following sizes as specified. Excavation will be measured separately (Refer Sec VI, Clause No.10.6). 180 Straight Through Joint (Crimping type) for 4 Core, 10 - 16 Sq. mm 181 Straight Through Joint (Crimping type) for 3.5 Core, 25- 50 Sq. mm 182 Straight Through Joint (Crimping type) for 3.5 Core, 70-95 Sq. mm 183 Straight Through Joint (Crimping type) for 3.5 Core, 120 - 185 Sq. mm 184 Straight Through Joint (Crimping type) for 3.5 Core, 240 Sq. mm 185 Straight Through Joint (Crimping type) for 3.5 Core, 400 Sq. mm 186 Supply, installation, testing and commissioning of the following Raychem make Heat Shrinkable Cable Straight Through Jointing Kits (Mechanical Connector type/Crimping type) Rayfit tubing for 3 Core Aluminium Conductor, 11 kV (E), XLPE insulated cables of following sizes including excavation of soil, backfilling etc as specified. (Refer Sec VI, Clause No.10.6). 187 Straight Through Joint (Crimping type) for 3 Core x 185 Sq. mm 188 Supply, installation, testing and commissioning of Raychem make the following Heat Shrinkable Cable End Termination without gland for 3 Core Aluminium Conductor, 11 kV, XLPE insulated cables of following sizes. (Refer Sec VI, Clause No.10.5). 189 3 Core x 185 Sq.mm XLPE (Indoor) 190 HT/LT Cable Fault Tracing and Locating by using TNEB Cable Fault Identification Kit including HT/LT Cable Route Tracing, Transportation from chennai to Kalpakkam/Anupuram Township and back to chennai and Transporting the kit within Kalpakkam/Anupuram Township 191 Cutting, Grinding, painting the grinded edges and positioning of 6mm thick chequered plates including transportation of chequered plates with in townships including supply ofgas cylinder, consumables etc, as per the detailed specification and as directed by Engineer In Charge. 192 Excavation in hard soil including refilling with excavated earth and disposing surplus earth at places as directed with in a lead of 10 Mtrs. and initial lift upto 1.5 Mtrs. including neat banking as per detailed specification. (Refer Sec VI, Clause No.2)

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 22-08-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 26-08-2024

Key Value

Document Fees
Refer document
EMD
INR 134600.0 /-
Tender Value
INR 67.30 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail