}

Tender For Work Related To Electrification (Running Contract) Under The Honorable Mp/Mla Fund And Other Deposit Scheme Under Power Distribution Division-Iii (Bisauli), Badaun., budaun-Uttar Pradesh

Boards / Undertakings / PSU has published Tender For Work Related To Electrification (Running Contract) Under The Honorable Mp/Mla Fund And Other Deposit Scheme Under Power Distribution Division-Iii (Bisauli), Badaun.. Submission Date for this Tender is 21-08-2024. Conductor Tenders in budaun Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

44446426
Corrigendum : Tender For Work Related To Electrification (Running Contract) Under The Honorable Mp/Mla Fund And Other Deposit Scheme Under Power Distribution Division-Iii (Bisauli), Badaun.
Open Tender
Indian
Uttar Pradesh
Budaun
21-08-2024

Tender Details

tender for Work related to electrification (running contract) under the Honorable MP/MLA Fund and other deposit scheme under Power Distribution Division-III (Bisauli), Badaun, Running Contract for hon,ble Sansad Nidhi/Vidhayak Nidhi and other Deposit Works under EDD-III (Bisauli), Budaun. Sl. No. Item Description 1 The work of safe carriage of the following material from Nawada store center to work site under the jurisdiction of EDD-III (Bisauli), Budaun. Approx. distance upto 60 Km. Including safe loading and unloading. 2 PCC Pole 8.5 meter long. 3 STP 11 Mtr Long 4 Line material i.e., cross arm/ conductor/ pin insulater/stay/earthing rod/Disc Fitting/Disc Insulators/11 KV XLPE Cable etc. 5 11/0.4 KV 1 Phase 10/16 KVA T/F 6 11/0.4 KV 3 Phase 25 KVA T/F 7 11/0.4 KV 3 Phase 63 KVA T/F 8 11/0.4 KV 3 Phase 100 KVA T/F 9 11 KV Pilfer proof Metering cubical and CT PT Unit 10 33 KV Pilfer proof Metering cubical and CT PT Unit 11 Erection of new PCC Single/Double pole in H.T/L.T lines including fitting of all accessories as per RESSPO Norms. 12 PCC Pole 8.5 Mtr Long Single Pole 13 PCC Pole 8.5 Mtr Long Double Pole 14 ST Pole 11 Mtr Long Single Pole. 15 ST Pole 11 Mtr Long Double Pole. 16 Grouting with 1:4:8 mixture in size(450x450x1500mm.) including cost of cement/C.C. & sand Required as per RESSPO Norms. 17 PCC Pole 8.5 Mtr Long Single Pole 18 PCC Pole 8.5 Mtr Long Double Pole 19 ST Pole 11 Mtr Long Single Pole. 20 ST Pole 11 Mtr Long Double Pole. 21 The work of Driving the earthing electrode and making connections with 6 S.W.G. GI wire as per RESSPO Norms. 22 Laying, Stringing & Sagging of Following Conductor complete in all respect. 23 ACSR Weasal Conductor 24 ACSR Dog Conductor 25 3 Phase Arial Bunched Conductor 26 1 Phase Arial Bunched Conductor 27 After Mounting of CT PT unit on double pole, laying of 50 Mtr 11 KV 3cx70 sq mm cable in single circuit on river sand form Double Pole to meetering room complete in all respect. Alongwith filling of 04 nos cable jointing kits 28 After Mounting of CT PT unit on double pole, laying of 50 Mtr 33 KV 3cx120 sq mm cable in single circuit on river sand form Double Pole to meetering room complete in all respect. Alongwith filling of 04 nos cable jointing kits. 29 Under ground laying of Following cable in Single circuit on river sand to Double pole situated at both sides of road complete in all respect. Minimum depth should be 0.75 Mtr and cable should be covered by bricks from three sides. Alongwith filling of 04 nos cable jointing kits. 30 LT Cable Size 1x240 sqmm 31 11 KV XLPE Cable Size 3x70 sqmm 32 11 KV XLPE Cable Size 3x120 sqmm 33 11 KV XLPE Cable Size 3x185 sqmm 34 33 KV XLPE Cable Size 3x120 sqmm 35 33 KV XLPE Cable Size 3x185 sqmm 36 33 KV XLPE Cable Size 3x300 sqmm 37 Under ground laying of Following cable in Single circuit by drill method to Double pole situated at both sides of NH/SH/Railway Crossing complete in all respect. Alongwith filling of 04 nos cable jointing kits. 38 11 KV XLPE Cable Size 3x70 sqmm 39 11 KV XLPE Cable Size 3x120 sqmm 40 11 KV XLPE Cable Size 3x185 sqmm 41 33 KV XLPE Cable Size 3x120 sqmm 42 33 KV XLPE Cable Size 3x185 sqmm 43 33 KV XLPE Cable Size 3x300 sqmm 44 The work of digging of pits, erection of Stay Clamp, Insulator etc. 45 Grouting of stays, 1:4:8 cc ratio (600x600x300mm.) as per RESPO norms. 46 Installation of 11 KV Pilfer Proof Metering Cubicle in metering room complete in all respect 47 Installation of 33 KV Pilfer Proof Metering Cubicle in metering room complete in all respect 48 Mounting of Following Capacity Transformers as per norms complete in all respect - 49 10/16 KVA T/F 50 25 KVA T/F 51 63 KVA T/F 52 100 KVA T/F 53 Fixing of Distribution Box complete in all respect 54 Guarding at road crossing complete in all respect 55 11 KV VCB incoming/outgoing loading/unloading and installation 56 The following Decentralized material shall be provided by the contractor for execution of work as per RESPO Norms (the material shall be purchased from approved vendor of Discom). 57 11 KV F Clamp 58 Holding Clamps forTop Channel, T Off Channel, V Type X-Arm 59 Nut & Bolts 60 Stay Clamp 61 Safe back carriage of Scrap (if any) from work site to Nawada store Budaun approx distance upto 60 Km including safe loading & unloading.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 02-08-2024 DATE EXTENSION1 Date 05-08-2024
2 05-08-2024 DATE EXTENSION8 Date 13-08-2024
3 13-08-2024 DATE EXTENSION9 Date 21-08-2024

Key Value

Document Fees
INR 3540 /-
EMD
INR 20000.0 /-
Tender Value
INR 20 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail