| 1 | Taking down carefully copper/aluminium point wiring (light/fan/Bell/ socket or power point) complete inclusive of all fittings, removing materials from site and making good disturbed surfaces of floors /walls/ceiling etc all as directed. |
| 2 | Materials and labour for concealed point wiring with 1.50 Sq.mm. PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volts grade, single core, laid in and including PVC conduit not less than 20mm dia with all assessories such as junction box, MS coupling, unions bench, reducers, elbow, sealing conduit etc on wall surfaces/ roof and,including 1.50 Sq.mm PVC insulated, unsheathed multistranded copper conductor FRLS cable(green colour) 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly for one light/fan/socket point controlled by oneswitch complete all as specified and directed. |
| 3 | Materials and labour for concealed power point wiring with 2.5 Sq.mm. PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volts grade, single core, laid in and including PVC conduit not less than 20mm dia with all assessories such as junction box, MS coupling, unions bench, reducers, elbow, sealing conduit etc on wall surfaces/ roof and, including including 2.50 Sq.mm PVC insulated, unsheathed multistranded copper conductor FRLS cable(green colour) 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly for one 3/5Pin 6/16 Amps socket outletindependent board complete all as specified and directed. |
| 4 | Supply and fix in replacement of MCB SP 6 to 32 Amps 10KA ‘B’ curve 240 voltsMake complete all as specified and as directed. Make : Standard/Ship/Havell’s./Indo Asian |
| 5 | Supply and fix in replacement MCB SPN 40 Amps 10 KA ‘B’ curve 240 volts complete all as specified and as directed.Make : Standard/Ship/Havell’s./Indo Asian |
| 6 | Supply and fix in replacement of MCB TPN 63 Amps 10 KA ‘C’ curve 415 volts omplete all as specified and as directed.Make : Standard/Ship/Havell’s./Indo Asian |
| 7 | Supply and fixing in replacement of sheet metal enclosures DB’s when MCBs to be used for 240 volts, 4 way SPN, double door with 200 Amps rated bus bar including earth and neutral link complete all as specified and as directed. |
| 8 | Supply and fixing in replacement of sheet metal enclosures DB’s when MCBs to be used for 240 volts, 8 way SPN, double door with 200 Amps rated bus bar including earth and neutral link complete all as specified and as directed. |
| 9 | Supply and fixingin replacement of sheet metal enclosures DB’s when MCBs to be used for 415 volts, 4 way TPN, vertical type, double door with 200 Amps rated bus bar including earth and neutral link complete all as specified and as directed. |
| 10 | Material and Labour in replacement for submain wiring with two runs of single 4 sqmm PVC insulated unsheathed multistranded 1100 vols grade with copper conductor drawn through and including in steel conduit medium grade ISI marked and its accessories including one run of single core 4 sqmm PVC insulated unsheated multistranded 1100 volts grade with copper conductor cable as earth contuinity conductor along with the wiring and connected from DB to DB/ main board completeall as specified and as correct. |
| 11 | Material and Labour in replacement for earthing complete with copper earth plate electrode 600mm x 600mm x 3.15 mm thick buried directly in ground earth pit not less than 2.25 mtr below normal GL with the top edge of the plate not less then 1.5 mtr below the normal GL connected to 20X3mm copper strip as earth lead by means of bolts, nuts, check nuts and washer of brass and protected by 40 mm GI pipe (light grade) and watering pipe 20mm bore GI pipe (light grade) including GI wire meshed funnel and chamber PCC (1:4:8) type D2 using 40mm grade stone aggregate, coping shall be (1:3:6) type CI using 20mm stone aggregate with RCC 1:2:4 type B1 (using 20mm graded stone aggregate) pit cover re-inforced with 8mm dia at 80mm c/c both way in lieu of CI pit cover with angle iron frame, including excavation and earth work in any type of soil and removal of surplus soil of earth complete all as shown in electrical plate of SSR Part I and as specified including charcoal dust, common salt complete and earth lead connected to earthing test point all as specified and testing of earthing on completion. NOTE 1. The unit rate includes for protection pipe and copper strip 20X3mm from top of earth plate up to 7.5 meter above ground level. |
| 12 | Supply and fix in replacement of modular switch6 amp 230 V AC one way, one module complete all as specified |
| 13 | Supply and fix in replacement ofmodular switch 15/20 amp 230 V AC one way, with indicator one module complete all as specified |
| 14 | Supply and fix in replacement ofModualr Socket 6A, 2/3 pin two module combined complete all as specified. |
| 15 | Supply and fix in replacement of Modular socket, 16A, 2/3 pin, two module complete all as specified. |
| 16 | Supply and fix in replacement ofmodularfan regulatorstep type, 120W, 2 module complete all as specified |
| 17 | Supply and fix in replacement ofwhite colour plates withframe formodular switchof 01module complete all as specified |
| 18 | Supply and fix in replacement ofwhite colour plates withframe formodular switchof 03module complete all as specified |
| 19 | Supply and fix in replacement ofwhite colour plates withframe formodular switchof 04module complete all as specified |
| 20 | Supply only in replacement ofwhite colour plates withframe formodular switchof 06module complete all as specified |
| 21 | Supply and fix in replacement ofwhite colour plates withframe formodular switchof 08module complete all as specified |
| 22 | Supply and fix in replacement ofceiling rose surface bakelite 65 x 50mmthree terminals complete all as specified.Make : Havells/SSK/Leader |
| 23 | Supply and fix in replacement ofswitch piano flush type 5 Amp single pole one way complete all as specified.Make : Havells/SSK/Leader |
| 24 | Supply and fix in replacement ofswitch piano flush type 15 Amp single pole one way complete all as specified.Make : Havells/SSK/Leader |
| 25 | Supply and fix in replacement ofswitch piano 5 Amp flush type single pole two way complete all as specified.Make : Havells/SSK/Leader |
| 26 | Supply and fix in replacement ofsocket outlet 5 pin 5 Amps flush type multi purpose complete all as specified.Make : Havells/SSK/Leader |
| 27 | Supply and fix in replacement ofsocket outlet multipurpose 2 in one, 6 pin 15A mps flush type.Make : Havells/SSK/Leader |
| 28 | Supply and fix in replacement ofangular lamp holder insulated body with back plate suitable for pendent fittings complete all as specified.Make : Havells/SSK/Leader |
| 29 | Supply and fix in replacement of call bell single phase 240 volt complete all as specified. |
| 30 | Supply and fix in replacement ofbell push flush type 5 Amps complete all as specified.Make : Havells/SSK/Leader |
| 31 | Supply and fix in replacement offan regulator electronic step type and making connection. Make : Rallison/Leader/Bajaj |
| 32 | Supply and fix in replacement of single pole and neutral enclosure with a two pin and earth plug and socket complete with one single MCB 20 Amp complete all as specified Make :Standard/Havells/Ship |
| 33 | Supply and fix in replacement ofLED Lamp 9 watt complete all as specified.Make : Philips/Bajaj/Wipro |
| 34 | Supply and fix in replacement ofLED Lamp 5 watt complete all as specified.Make : Philips/Bajaj/Wipro |
| 35 | Supply and fix in replacement ofLED Lamp 12 watt complete all as specified.Make : Philips/Bajaj/Wipro |
| 36 | Supply and fix in replacement of LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. Make Philips / Bajaj/Havells |
| 37 | Supply and fix in replacement of LED tube light fitting 1 x 18 Watt, wall mounted LED batten with polycarbonate housing & integrated electronic driver LUMILINEBS18WLED865SPCWH of Make Philips / Bajaj/Havells complete all as specified and directed. |
| 38 | Supply and fix in replacement ofLED Tube light fitting new e-Lite LeD Curve. high lumen batten with efficacy of 100 Lumens. Available in10W LED 600 K LheXBXPnin1W010complete all as specified.Make : Crompton Greaves/Philips/Bajaj/Wipro |
| 39 | Supply and fix in replacement ofLED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified.Make : Crompton Greaves/Philips/Bajaj/Wipro |
| 40 | Supply and fix in replacement ofLED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified. Make : Crompton Greaves/Philips/Bajaj/Wipro |
| 41 | Supply and fixin replacement plug top 3 pin, 5 Ampscomplete all as specified and as directed. |
| 42 | Supply and fix in replacement plug top 3 pin, 15 Ampscomplete all as specified and as directed. |
| 43 | Supply and fix in replacement ofround shape 12 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete complete all as specified and directed, |
| 44 | Supply and fix in replacement ofround shape 6 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete complete all as specified and directed. |
| 45 | Supply and fix in replacementof single corewire 2.5 Sqmm multi-strand PVC insulated copper conductor FRLS cable including connections of cable with MCBs or bus bars complete all as specified and directed. |
| 46 | Supply and fix in replacementof single corewire 1.5 Sqmm multi-strand PVC insulated copper conductor FRLS cable including connections of cable with MCBs or bus bars complete all as specified and directed. |
| 47 | Supply and fix inreplacement of capacitor AC 230 volts 2.5 MFD complete all as specified and directed. |
| 48 | Supply and fix in replacementof LED Tube rod for double/single side 15 Wcomplete all as specified and directed. Make Havells/Bajaj/Crompton |
| 49 | Supply and fix in replacementof LED Tube rod for double/single side 18 Wcomplete all as specified and directed. Make Havells/Bajaj/Crompton |
| 50 | Supply and fix in replacementof LED Tube rod for double/single side 20 Wcomplete all as specified and directed. Make Havells/Bajaj/Crompton |
| 51 | Supply only PVC Casing and Capping 20 mm ISI Marked. all as specified and directed. |
| 52 | Supply only tape insulation 10 mtr long all as specified. |
| 53 | Supply and fix in replacementof , Post Top,energy saving,environmental friendly,long life aesthetically designed with symmetrical light distribution,spun aluminium landscape luminaire with high power LEDs as light source CORAL (OPAL) - IP 65 CORALMINIPT15WLED757PSYMTOPCMake : Havells or equivalent |
| 54 | Attending of day to day electrical complaints pertaining to internalelectrification received through telephone/ Armaan or in person on detailment at MES Service centre located at Suranussi Areaby locating and rectification of fault from and including electric meter/DB onwards in respect of sub main/point wiring including provisioning of small pieces of electric cable of size 1.5/2.5 Sqmm to 10 Sqmm single core copper conductor and length not increasing 0.50 mtrs and fixtures for power and light socket/light, fan and bell etc complete and carrying out repairs to the extent of tightening of loose connections, disconnection anddismantling of faulty wires, battens, conduits, boxes, main switches, MCB\"s, DB\"s and other E/M fixturesincluding providing necessary screws / nuts / bolts / nailsfor the rectification of defect and refixing of existing dismantled serviceable items and replacement of defective items with new ones complete all as specified and directed. Note - (i) Cost of labour (two Electrian and two helper detail for contractor daily basis at 9:00 hrs AM to 1700 hrs PM till complection of contract apprx nine months)for the fixing/replacement of unserviceable item shall deemed to be included in item and cost of store replaced shall be measured as supply only against relevant Items.(ii) Complaint pertaining to location and rectification of fault in more than one length of point wiring/sub main wiring/DB\"s/fitting or fixtures etc shall be considered as an independent complaint. Similarly complaint pertaining to replacement oftwo fixtures in one Qtr will also be measured and paid as one complaint.(iii) Replacement of more than two fixtures/itemsbut multipleof three fixtures or part thereof in one Qtr/Bldg will be measured as an additional complaint.(iv) In case a Qtr/room is found locked when tradesman is detailed to attend the complaint, the complaint shall be treated as one till its completion.(v) Necessary tools for tradesman shall be provided by the contractor.(vi) Transportation for tradesman and normal stores required for complaints shall be arranged by the contractor.(vii) Complaints of normal nature shall be attended and rectified within 8Hrs of receipt of complaint. However, complaints of emergent naturei.e no light, short circuit, earth fault etc shall be attended immediately onreceipt of complaint round the clock. (viii) Bldgs requiring rewiring of small qty of point wiring if ordered will be measured and paid separately under respective items below(ix) Contractor will deposit all the items to EM Store in advance and unsv items will be collected by the contractor as schedule of credit(x) Electrician will report to AGE EM complaint cell at 9 O\"Clock to 1700 hrs daily for collecting of complaints. Complaint received on Armaan application will be done in the same day and after completion of complaint Electrician will report to Armaan Cell for uploading the completion report.(xi) Contractor deploy local electrician for the job so that urgent nature of complaintlike no light, short circuit and earth fault will also done on Holidays/ Sunday. |