}

Tender For Construction Of Integrated Tourism Development And Beautification Works At Bhagwan Parshuram Mandir At Jalalbad Distt. Shahjahanpur (U.P.), 1 Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) / Manual Means In Foundation Tre, bareilly-Uttar Pradesh

Government Departments has published Tender For Construction Of Integrated Tourism Development And Beautification Works At Bhagwan Parshuram Mandir At Jalalbad Distt. Shahjahanpur (U.P.), 1 Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) / Manual Means In Foundation Tre. Submission Date for this Tender is 09-08-2024. Septic Tank Tenders in bareilly Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

44365933
Tender For Construction Of Integrated Tourism Development And Beautification Works At Bhagwan Parshuram Mandir At Jalalbad Distt. Shahjahanpur (U.P.), 1 Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) / Manual Means In Foundation Tre
Open Tender
Indian
Uttar Pradesh
Bareilly
09-08-2024

Tender Details

Tender For Construction Of Integrated Tourism Development And Beautification Works At Bhagwan Parshuram Mandir At Jalalbad Distt. Shahjahanpur (U.P.), 1 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 2 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil. 3 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and all lift 4 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. 5 Close timbering in trenches including strutting, shoring and packing cavities (wherever required) complete. (Measurements to be taken of the face area timbered). 6 Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mmapart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor With Chlorpyriphos/Lindane E.C. 20% with 1% concentration 7 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. 8 CC ROAD WORK IN CAMPUS AREA 9 RCC DRAIN (450X450 MM) 10 Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses,parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing:1:1½:3 (1 cement : 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). 11 Providing and laying in position ready mixed or site batched design mix cement concrete for plain cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana/Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering and finishing as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the minimum specified cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works upto plinth level :Concrete of M10 grade with minimum cement content of 220 kg /cum 12 Providing and fixing up to floor five level precast cement concrete string or lacing courses, copings, bed plates, anchor blocks, plain window sills, shelves, louvers, steps, stair cases, etc., including hoisting and setting in position with cement mortar 1:3 (1 Cement : 3 coarse sand), cost of required Centering complete.1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20mm nominal size derived from natural sources) 13 Providing and laying damp-proof course 40mm thick with cementconcrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from naturalsources : 4 graded stone aggregate 12.5mm nominal size derived fromnatural sources) 14 Centering and shuttering including strutting, propping etc. and removal of form Foundations, footings, bases of columns, etc. for mass concrete 15 Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. 16 Columns, Pillars, Piers, Abutments, Posts and Struts 17 Suspended floors, roofs, landings, balconies and access platform 18 Lintels, beams, plinth beams, girders, bressumers and cantilevers 19 Stairs, (excluding landings) except spiral-staircases 20 Edges of slabs and breaks in floors and walls 21 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarseaggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works upto plinth level Concrete of M25 grade with minimum cementcontent of 330 kg /cum 22 All works above plinth level upto V floors Concrete of M25 grade with minimum cementcontent of 330 kg /cum 23 Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete upto plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more 24 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand) 25 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) 26 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement :3 coarse sand) 27 Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry. 28 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). SAL WOOD 29 Providing and fixing panelled or panelled and glazed shutters for doors,windows and clerestory windows, fixing with butt hinges of requiredsize with necessary screws, excluding panelling which will be paid forseparately, all complete as per direction of Engineer-in-charge. (Note:-Butt hinges and necessary screws shall be paid separately) Second class teak wood35 mm thick shutters 30 Providing and fixing ISI marked flush door shutters conforming to IS :2202 (Part I) decorative type, core of block board construction withframe of 1st class hard wood and well matched teak 3 ply veneeringwith vertical grains or cross bands and face veneers on both faces ofshutters. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 31 Extra for Providing and fixing flush doors with decorative veneering insteadof non decorative ISI marked flush door shutters conforming to IS: 2202(Part I) On one side only 32 Providing and fixing of factory made uPVC Sliding window & door (White Colour) complete, comprising uPVC multi-chambered frame having in-built uPVC roller track on top and uPVC sash with wall thickness of 2.3mm (+-0.2 mm), duly reinforced with G.I. section1.5 mm, wherever required.uPVC window & door profile shall be made in India & shall conform to BS EN 12608 and other standards as mentioned below:S.No. Name of the testTest MethodSpecified Parameter1 Tensile Impact StrengthISO 8256- more than700Kj/m22 Vicat Softening Temperature EN ISO – 306 Shall not be < 750C3 Charpy Impact Strength EN ISO – 179-2 Shall not be < 20KJ/m24 Flexural Modulus Elasticity EN ISO – 178 Shall not be < 2200 N/mm25 Mean Breaking Stress for welded corner(a) For the tensile bending test EN – 514 Shall not be < 25 N/mm2(b) For the compression bending test Shall not be < 30N/mm26 Heat Reversion Test IS:4985-2000 Shall not be > 2.0 %7 Surface Spread of flame BS : 476 - Part 7 Classification 18 Ignitability Evaluation BS : 476 - Part 5 P Not easily ignitable9 Tensile modulus ASTM D 638 Shall not be < 35 MPa10 Shear Modulus ASTM D 732 Shall not be < 220 MPa11 Tensile Strength EN ISO 527 Shall not be < 30 MPaAll corners of frame and sash will be fusion welded. After placing 5 mm Float Annealed glass in the sash, uPVC glazing bead, interlock, EPDM / TPE gasket, brush shall be provided including touch lock and rollers & proper drainage system shall be provided. Window / Door will be fixed to the wall with 100mm long and 8mm dia. Fasteners and complete in all respect as per direction of Engineer-In-Charge.uPVC Window and Door Profiles are warranted for a period of ten (10) years against non-uniform discoloration, wrapping and rotting under general use. Two track two panels sliding window made of (big series) frame 67 x 50 mm & sash 46 x 62 mm both having wallthickness of 2.3 ± 0.2 mm and single glazing bead / doubleglazing bead of appropriate dimension. (Area of windowabove 2.50 sqm upto 4.00 sqm.) 33 Fly proof stainless steel grade 304 wire gauge with 0.5 mm dia. wire and 1.4mm wide aperture with matching wood beading 34 Providing 40x5 mm flat iron hold fast 400 mm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 300x100x150 mm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size). 35 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 36 Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below:1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 nos.2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12hrs.3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs.4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.) 37 Providing and fixing Single Glazing 6mm thick toughened glass complete in all respects as per direction of the Engineer-in-charge. (Required properties Solar factor ≤ 0.45, U-Value ≤ (W/sq.m-K) 5.7W /M2K, Visible light transmittance ≥ 0.30) 38 Providing and fixing chromium plated brass curtain rod having wall thickness of 1.25mm with two chromium plated brass brackets fixed with C.P. brass screws and PVC sleeves etc., wherever necessary complete :25 mm dia 39 Providing and fixing bright finished brass butt hinges with necessary screws etc. complete: 125x 85x5.5mm 40 Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. 41 Providing and fixing bright finished brass door latch with necessary screws etc. complete.:250 x 16 mm 42 Providing and fixing approved brand and manufacture BrassTower bolt 250 mm long with 10mm dia fixed with screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 43 Providing and fixing approved brand and manufacture Brass Tower bolt 150mm long with 10mm dia fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 44 Providing and fixing approved brand and manufacture SS 304 grade wall mounted door buffer fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 45 Providing and fixing brightfinished brass hanging type floor door stopper with necessary screws, etc complete 46 Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixingaccessories such as nuts, bolts, fasteners etc.). 47 Steel work welded in built up sections/ framed work, including cutting,hoisting, fixing in position and applying a priming coat of approved steelprimer using structural steel etc. as requiredIn gratings, frames, guard bar, ladder, railings, brackets, gates and similar works 48 Providing and fixing angle iron frames for doors, windows and ventilators of mild steel angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary ed steel primer, all complete as per the direction of Engineer-In-charge. 49 Providingstructuralsteelworkofrectangularhollowsteelsectionforsteeltrusses,other similartrusseditemslikepurlinandmemberswithallbracing,gussetplatesetc.asper detailed designs and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing inpositionmaking riveted/bolted/weldedconnectionsandonecoatofanticorrosive paint and over it two coats of oil painting of approved quality and shade complete. 50 Providing and fixing gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counterls, window sills, facias, etc….Granite stone slab: black, cherry/ ruby red 51 providing edge moulding 18mm thk in granite for vanity and kitchen counters 52 Extra for fixing marble/ granite stone over and above coreesponding items in facia and drops 53 Extra for providing opening for required size for wash basins and taps 54 Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in allcolours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. Thetiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Glazed Vitrified tiles Matt/Antiskid finish of size 55 Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building allcomplete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.: Polished Granite stone slab colour of Black, Cherry/Ruby Red or equivalent 56 Providing and laying Ceramic glazed floor tiles of size 300x300 mm(thickness to be specified by the manufacturer) of 1st quality conformingto IS : 15622 of approved make in colours such as White, Ivory, Grey,Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement :4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm includingpointing the joints with white cement and matching pigment etc.,complete. 57 Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection> 0.70 and initial emittance > 0.75 on waterproof and slopedsurfaceof terrace, laid on 20 mm thick cement sand mortar in the ratio of1:4 (1 cement : 4 coarse sand) and grouting the joints with mix ofwhite cement & marble powder in ratio of 1:1, includingrubbing andpolishing of the surface upto 3cuts complete, including providingskirting upto 150mm height along the parapet walls in the same manner. 58 12mm cement plaster of mix : 1:6 (1 cement : 6 fine sand) 59 15 mm cement plaster on the rough side of single or half brick wall of mix : 1:6 (1 cement : 6 coarse sand) 60 Providing & fixing Chicken wire mesh on joints of RCC & Brick work before plastering complete in the direction of Engineer-in-charge. 61 Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. 62 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 63 Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats 64 Providing & Applying high quality acrylic modified resin based texture of Dholpur/Red sand stone Pattern with anti algae and UV resistance properties to be applied as intermediate finish in desired pattern @ 43.04 kgs/10 sqm to form film of 1- 1.5 mm thickness after scrapping and properly cleaning the surface to remove loose particles from the plaster surface, followed by top coating with Premium Acrylic Smooth exterior paint with Silicone additives of required shade by two or more coats @ 1.43 litres/10 sqm, complete as the direction of Engineer -in-Charge 65 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operation(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer in-charge to required slope and treating similarly the adjoiningwalls upto 300 mm height including rounding of junctions of walls and slabs.(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge.(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge :With average thickness of 120 mm and minimumthickness at khurra as 65 mm. 66 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : 67 : Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections,power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide × 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia × 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25×10×0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45×15×0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia × 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceilin fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section andperimeter channel with the help of dry wall screws of size 3.5 × 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturers specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with12.5 mm thick tapered edge gypsum moisture resistant board 68 PROVIDING AND FIXING PEDESTAL ( SINGLE PIECE ) IN RED SAND STONE IN MALE - FEMALE JOINERY, WITH GROOVES AND MOULDINGS TO BE FIXED WITH ADHESIVE, CEMENT SLURRY, BRASS PINNING AND APPLYING ANTI-MOSS TREATEMENT AS PER DRAWING, DESIGN AND THE DIRECTION OF THE SITE ENGINEER/ CONSULTANT INCLUDING TRANSPORTATION, LOADING, UNLOADING, STACKING, SCAFFOLDING, CLEANING , FIXING, JOINT FILLING, POLISHING, GRINDING, NECESSARY LIFTING MACHINERY, PLACING, ETC. COMPLETE.(PRIOR APROVAL OF SAMPLE/ BRAND BY EXEC. ENGINEER IS NECESSARY BEFORE USE ) SPEC. NO. : AS DIRECTED BY ENGINEER IN -CHARGE.(PEDESTAL -RED SAND STONE) FROM: FINISHED SIZE = ( 0.450X0.450X0.60 ) 69 PROVIDING AND FIXINGSQUARE COLUMN( SINGLE PIECE ) IN RED SAND STONECARVING AND WITH MACHINE, GROOVES AND MOULDINGS TO BE FIXED WITH ADHESIVE, WHITE CEMENT, CEMENT SLURRY, BRASS PINNING ETC.. AS PER DRAWING, DESIGN AND THE DIRECTION OF THE SITE ENGINEER/ CONSULTANT INCLUDING TRANSPORTATION, LOADING, UNLOADING, STACKING, SCAFFOLDING, CLEANING , FIXING, JOINT FILLING, POLISHING, GRINDING, NECESSARY LIFTING MACHINERY, PLACING,ETC. COMPLETE.(PRIOR APROVAL OF SAMPLE/ BRAND BY EXEC. ENGINEER IS NECESSARY BEFORE USE ) SPEC. NO. : AS DIRECTED BY ENGINEER IN -CHARGE.(SQUARE COLUMN - RED SAND STONE) FROM:FINISHED SIZE = (0.3X 0.3)M 70 PROVIDING AND FIXING MIDDEL CAPITAL( ONE PIECE ) INRED SANDSTONE IN MALE -FEMALE JOINERY WITHGROOVES AND MOULDINGS TO BE FIXED WITH ADHESIVE, CEMENT SLURRY, BRASS PINNING ETC. COMPLETE AND APPLYING ANTI-MOSS TREATEMENT AS PER DRAWING, DESIGN AND THE DIRECTION OF THE SITE ENGINEER/ CONSULTANT INCLUDING TRANSPORTATION, LOADING, UNLOADING, STACKING, SCAFFOLDING, CLEANING , FIXING, JOINT FILLING, POLISHING, GRINDING, NECESSARY LIFTING MACHINERY, PLACING,ETC. COMPLETE.(PRIOR APROVAL OF SAMPLE/ BRAND BY EXEC. ENGINEER IS NECESSARY BEFORE USE ) SPEC. NO. : AS DIRECTED BY ENGINEER IN -CHARGE.( MIDDEL CAPITAL - RED SANDSTONE I) FROM:FINISHED SIZE = ( 0.500 X 0.500X 0.200 ) 71 PROVIDING AND FIXING SAND STONE BEAM WITH MOULDING IN MALE - FEMALE JOINERY WITHGROOVES AND MOULDINGS TO BE FIXED WITH ADHESIVE, CEMENT SLURRY, BRASS PINNING ETC. COMPLETE AND APPLYING ANTI-MOSS TREATEMENT AS PER DRAWING, DESIGN AND THE DIRECTION OF THE SITE ENGINEER/ CONSULTANT INCLUDING TRANSPORTATION, LOADING, UNLOADING, STACKING, SCAFFOLDING, CLEANING , FIXING, JOINT FILLING, POLISHING, GRINDING, NECESSARY LIFTING MACHINARY, PLACING, ETC. COMPLETE. FINISHED SIZE = (0.400 wide X 0.350 Ht. )(EXCLUDING GST AND ROYALTY) 72 PROVIDING AND FIXING ORNAMENTAL JALLI 100 mm THK) OF MUGAL ERA PATTERN IN RED SAND STONE VERTICALY PLACED IN SLAB BOTTOM NEAR DOME AREA OF REQUIRED SIZE AND SHAPED IN MALE - FEMALE JOINERY WITHGROOVES AND MOULDINGS TO BE FIXED WITH ADHESIVE, CEMENT SLURRY, BRASS PINNING ETC. AS PER DRAWING, DESIGN AND THE DIRECTION OF THE SITE ENGINEER/ CONSULTANT INCLUDING TRANSPORTATION, LOADING, UNLOADING, STACKING, SCAFFOLDING, CLEANING ,WHITE CEMENT,FIXING, JOINT FILLING, POLISHING, GRINDING, NECESSARY LIFTING MACHINERY, PLACING,ETC. COMPLETE.(PRIOR APROVAL OF SAMPLE/ BRAND BY EXEC. ENGINEER IS NECESSARY BEFORE USE ) SPEC. NO. : AS DIRECTED BY ENGINEER IN -CHARGE.(ORNAMENTAL JALLI - RED SAND STONE) - 100 MM THK 73 PROVIDING AND FIXING RED SANDSTONE BLOCK MASONARY WALLOF REQUIRED SIZE AND SHAPE WITH ALL EDGES ARE MACHINE CUT WITH V-GROOVING OF 6MM ON ALL EDGES INCLUDING CUTTING, DRESSING, POLISHING, GRINDING AS PER THE DETAILED DRAWINGS PROVIDED BY THE PROJECT CONSULTANT/ ARCHITECT, LOADING, UNLOADING, INSTALLATION, WITH HYDRA CRANE OR SIMILAR EQUIPMENTS, FIXING, APPLYING ANTI-MOSS TREATMENT ON SURFACES OF STONE WITH SPECIFIED CHEMICALS AS APPROVED BY THE ENGINEER-INCHARGE, ETC. COMPLETE(EXCLUDING GST AND ROYALTY) 74 PROVIDING AND FIXING ORNAMENTAL JALLI 100 mm THK) OF MUGAL ERA PATTERN IN RED SAND STONE VERTICALY PLACED IN SLAB BOTTOM NEAR DOME AREA OF REQUIRED SIZE AND SHAPED IN MALE - FEMALE JOINERY WITHGROOVES AND MOULDINGS TO BE FIXED WITH ADHESIVE, CEMENT SLURRY, BRASS PINNING ETC. AS PER DRAWING, DESIGN AND THE DIRECTION OF THE SITE ENGINEER/ CONSULTANT INCLUDING TRANSPORTATION, LOADING, UNLOADING, STACKING, SCAFFOLDING, CLEANING ,WHITE CEMENT,FIXING, JOINT FILLING, POLISHING, GRINDING, NECESSARY LIFTING MACHINERY, PLACING,ETC. COMPLETE.(PRIOR APROVAL OF SAMPLE/ BRAND BY EXEC. ENGINEER IS NECESSARY BEFORE USE ) SPEC. NO. : AS DIRECTED BY ENGINEER IN -CHARGE.(ORNAMENTAL JALLI - RED SAND STONE) - 100 MM THK 75 PROVIDING AND FIXING ORNAMENTAL JALLI 100 mm THK) OF MUGAL ERA PATTERN IN RED SAND STONE VERTICALY PLACED IN SLAB BOTTOM NEAR DOME AREA OF REQUIRED SIZE AND SHAPED IN MALE - FEMALE JOINERY WITHGROOVES AND MOULDINGS TO BE FIXED WITH ADHESIVE, CEMENT SLURRY, BRASS PINNING ETC. AS PER DRAWING, DESIGN AND THE DIRECTION OF THE SITE ENGINEER/ CONSULTANT INCLUDING TRANSPORTATION, LOADING, UNLOADING, STACKING, SCAFFOLDING, CLEANING ,WHITE CEMENT,FIXING, JOINT FILLING, POLISHING, GRINDING, NECESSARY LIFTING MACHINERY, PLACING,ETC. COMPLETE.(PRIOR APROVAL OF SAMPLE/ BRAND BY EXEC. ENGINEER IS NECESSARY BEFORE USE ) SPEC. NO. : AS DIRECTED BY ENGINEER IN -CHARGE.(ORNAMENTAL JALLI - RED SAND STONE) - 100 MM THK 76 PROVIDING AND FIXING RAILING WITH BALUSTREDS (1.40M LONG) & HAND RAIL (0.15M WIDE X 0.10M DEEP) IN RED SAND STONEAS PER DRAWING, DESIGN AND THE DIRECTION OF THE SITE ENGINEER/ CONSULTANT(PRIOR APROVAL OF SAMPLE/ BRAND BY EXEC. ENGINEER IS NECESSARY BEFORE USE ) INCLUDING ALL NECESSORY BRASS FITTINGS & OTHER FITTINGS, TRANSPORTATION, LOADING, UNLOADING, STACKING, CLEANING , WHITE CEMENT, FIXING, JOINT FILLING, POLISHING, GRINDING, NECESSARY LIFTING MACHINERY, PLACING, ETC. COMPLETE.(PRIOR APROVAL OF SAMPLE/ BRAND BY EXEC. ENGINEER IS NECESSARY BEFORE USE ) SPEC. NO. : AS DIRECTED BY ENGINEER IN -CHARGE.(RAILING WITH BALUSTREDS & HAND RAIL - WHITE RAJNAGARMARBLE) 77 PROVIDING AND FIXING RAILING WITH BALUSTREDS (1.40M LONG) & HAND RAIL (0.15M WIDE X 0.10M DEEP) IN RED SAND STONEAS PER DRAWING, DESIGN AND THE DIRECTION OF THE SITE ENGINEER/ CONSULTANT(PRIOR APROVAL OF SAMPLE/ BRAND BY EXEC. ENGINEER IS NECESSARY BEFORE USE ) INCLUDING ALL NECESSORY BRASS FITTINGS & OTHER FITTINGS, TRANSPORTATION, LOADING, UNLOADING, STACKING, CLEANING , WHITE CEMENT, FIXING, JOINT FILLING, POLISHING, GRINDING, NECESSARY LIFTING MACHINERY, PLACING, ETC. COMPLETE.(PRIOR APROVAL OF SAMPLE/ BRAND BY EXEC. ENGINEER IS NECESSARY BEFORE USE ) SPEC. NO. : AS DIRECTED BY ENGINEER IN -CHARGE.(RAILING WITH BALUSTREDS & HAND RAIL - WHITE RAJNAGARMARBLE) 78 PROVIDING AND FIXING PLAIN DADO FOR TREAD (37.5MM THK) IN RED SAND STONE OF APPROVED QUALITY MAKING THE REQUIRED PORTION IN LEVEL, IN CEMENT PLASTER 1:4 AND FIXING THE SLABS WITH READY MADE ADHESIVEINCLUDING TRANSPORTATION, LOADING, UNLOADING, STACKING, CLEANING ,WHITE CEMENT, FIXING, JOINT FILLING, MIRROR POLISHING, GRINDING, NECESSARY LIFTING MACHINERY, PLACING,ETC. COMPLETE.(PRIOR APROVAL OF SAMPLE/ BRAND BY EXEC. ENGINEER IS NECESSARY BEFORE USE ) SPEC. NO. : AS DIRECTED BY ENGINEER IN -CHARGE. 79 PROVIDING AND FIXING PLAIN DADO FOR RISER/SKIRTING (125MM WIDE & 37.5MM THK) IN WHITE RAJNAGAROR EQUIVALENT MARBLE OF APPROVED QUALITY VEIN AND COLOUR WITH MACHINE POLISH SURFACE AFTER MAKING THE REQUIRED PORTION IN LEVEL, IN CEMENT PLASTER 1:4 AND FIXING THE SLABS WITH READY MADE ADHESIVEINCLUDING TRANSPORTATION, LOADING, UNLOADING, STACKING, CLEANING ,WHITE CEMENT, FIXING, JOINT FILLING, MIRROR POLISHING, GRINDING, NECESSARY LIFTING MACHINERY, PLACING,ETC. COMPLETE.(PRIOR APROVAL OF SAMPLE/ BRAND BY EXEC. ENGINEER IS NECESSARY BEFORE USE ) SPEC. NO. : AS DIRECTED BY ENGINEER IN -CHARGE.(PLAIN DADO - WHITE RAJNAGARMARBLE ) - 125 MM WIDE 80 PROVIDING AND FIXING 0.025 M THK PLAIN CLADDING IN SAND STONEIN MALE - FEMALE JOINERY WITHGROOVES AND MOULDINGS AS PER DRAWING, DESIGN AND THE DIRECTION OF THE SITE ENGINEER/ CONSULTANT, TO BE FIXED ON M.S. STRUCTURAL FRAMEWORK WITH MECHANICAL FIXING, ADHESIVE OR CEMENT SLURRY OR BRASS PINNING, APPLYING ANTI-MOSS TREATEMENTINCLUDING TRANSPORTATION, LOADING, UNLOADING, STACKING, SCAFFOLDING, CLEANING , FIXING, JOINT FILLING, POLISHING, GRINDING, NECESSARY LIFTING MACHINARY, ETC. COMPLETE. (EXCLUDING GST AND ROYALTY) 81 PROVIDING AND FIXING 0.025 M THK PLAIN CLADDING IN SAND STONEIN MALE - FEMALE JOINERY WITHGROOVES AND MOULDINGS AS PER DRAWING, DESIGN AND THE DIRECTION OF THE SITE ENGINEER/ CONSULTANT, TO BE FIXED ON M.S. STRUCTURAL FRAMEWORK WITH MECHANICAL FIXING, ADHESIVE OR CEMENT SLURRY OR BRASS PINNING, APPLYING ANTI-MOSS TREATEMENTINCLUDING TRANSPORTATION, LOADING, UNLOADING, STACKING, SCAFFOLDING, CLEANING , FIXING, JOINT FILLING, POLISHING, GRINDING, NECESSARY LIFTING MACHINARY, ETC. COMPLETE. (EXCLUDING GST AND ROYALTY) 82 PROVIDING AND FIXING 0.025 M THK PLAIN CLADDING IN SAND STONEIN MALE - FEMALE JOINERY WITHGROOVES AND MOULDINGS AS PER DRAWING, DESIGN AND THE DIRECTION OF THE SITE ENGINEER/ CONSULTANT, TO BE FIXED ON M.S. STRUCTURAL FRAMEWORK WITH MECHANICAL FIXING, ADHESIVE OR CEMENT SLURRY OR BRASS PINNING, APPLYING ANTI-MOSS TREATEMENTINCLUDING TRANSPORTATION, LOADING, UNLOADING, STACKING, SCAFFOLDING, CLEANING , FIXING, JOINT FILLING, POLISHING, GRINDING, NECESSARY LIFTING MACHINARY, ETC. COMPLETE. 83 Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. 84 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. 85 Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead 86 Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge: All Kinds of Soil 87 Dismantling tile work in floor and roofs in laid in cement mortar including stacking material within 50 metres leadfor thickness of tiles 10mm to 25 mm 88 Disposel of Malwa By Tractor Trolly Withen (8 KM ) Long Distence 89 COST OF WATER POST 90 INTER LOCKING PEVAR ROAD 91 Cost for writing letters & LOGO 92 Cost of Statue of Bhagwan Parshuram at entrance gate 93 Cost of Toran in sand stone 7.7*3.00 m wide 0.280x0.280 with ornamental feature. 94 COST OF STONE SIGNAGE (2000 X1500)MM 95 Supply, and fixing in position 3 seater sand Stone Benches, 1800*900*450 mm at site as per approved quality and design. including all cost of accesories, transportation etc. complete in all respect. 96 Supply & Installation of 12W All in One Solar Street Light with System(Inbuilt Monocrystalline Module and LiFePO4 Batteries)12.8 volt 30 amp /hour on 6.0 Meters GI Tubular Pole, 3.2mmthick, complete in all respect (Make Wipro/Panasonic/Eveready/Nessa) 97 CEMENT 98 COURSE SAND 99 STONE AGGREGATE 100 STEEL 101 STONE 102 BRICK 103 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Angle back wash basin size 600 x 480 mm with single 15 mm C.P. brass pillar tap 104 Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid 105 Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests. 106 Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :One urinal basin with 5 litre white P.V.C. automatic flushing cistern 107 Providing and fixing 10 cm PVC nahani trap with grating etc. complete. 108 Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge 109 Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms: 15 mm nominal bore 110 18.53 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931: 15 mm nominal bore 111 Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet-150 mm diameter 112 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. 113 Providing and fixing PTMT soap Dish Holder having length of 138 mm, breadth 102 mm, height of 75 mm with concealed fitting arrangements, weighing not less than 106 gms. 114 Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. -600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. 115 For Wash Basin Counter-18 mm thick Flamed finish granite stone slab. 116 Providing and fixing CP Brass 32 mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. 117 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall-15 mm nominal dia Pipes 118 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall-20 mm nominal dia Pipes 119 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall-25 mm nominal dia Pipes 120 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall-32 mm nominal dia Pipes 121 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall-40 mm nominal dia Pipes 122 Providing ,laying and fixing P.V.C. pipe of 100 mm dia. with fittings such as bends, tees, reducers, clamps, etc. including necessary excavation, trench filling etc. complete. Including removing existing pipeline if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. 123 Providing and fixing 75mm dia stabiliser pipe /P.V.C. soilvent /wastepipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent,clamps etc. complete 124 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand: 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design :100 mm diameter S.W. pipe 125 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand: 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design :160 mm diameter S.W.pipe 126 Providing and fixing P.V.C. Rain water pipes of 160mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming to I.S. 13592-1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and One Number ,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete. 127 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand: 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design :200 mm diameter S.W. pipe 128 Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x 300 mm size (inside) the weight of cover to be not less than4.50 kg and frame to be not less than 2.70 kg as per standard design:With Sewer bricks conforming to IS : 4885 129 19.20 Supplying and fixing C.I. cover 300x300 mm without frame for gully trap (standard pattern) the weight of cover to be not less than 4.5 kg 130 Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement: 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design :Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg With Sewer bricks conforming to IS : 4885 131 Raising manhole cover and frame slab to required level including dismantling existing slab and making good the damage as required (Raising depth of manhole to be paid separately):Rectangular manhole 90x80 cm with rectangular cover 600 x 450 mm of grade LD - 2.5 132 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :32 mm nominal bore. 133 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :40 mm nominal bore. 134 Providing and fixing gun metal non- return valve of approved quality (screwed end) :32 mm nominal bore :Horizontal 135 Providing and fixing gun metal non- return valve of approved quality (screwed end) :40 mm nominal bore :Horizontal 136 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 137 Providing and fixing in position UPVC ultra violet stabilized 110 mm outer diameter cowl dome confirming to I.S.-4985 including making joints with solvent cement etc. complete 138 Cost of India Mark Hand Pump with All required Fittings 139 Cost of Sumbersible with Boring Complete Work 90 mtr Deep 140 Cost of Rain Water Harvesting in Campur Complete 141 Supplying, erecting, testing and commissioning self contained water cooler Cum Purifier 230/250V 50Hz nominal cooling capacity of 80 litres per hour and storage capacity 120 litres with partially stainless steel body. 142 SIZE OF TANK-Length = 5.7 M. Width =2.1 M Total Depth =3.00M Construction of Septic Tank With Brick Work ,Plaster, RCC Slab and All Required Accessories Complete Work 143 Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks of class designation 75 and S.W. drain pipe 100 mm diameter, 1.8m long complete as per standard design.With F.P.S. bricks 144 supplying, installaing, testing & commissioining of skid mounted packaged type sewage treatment plant complete with electromechanical equipments such as Manual type bar screen of 10 mm openings constructed of MS eposxy coated, Coarse aeration system of UPVC, sewage transfer pumps constructed of CI impellar for solid material handling of 10-15 mm size & liquid with specific gravity of 1.05 at ambient temperature ( one working & one standby) , Bio reactor chambers constructed of MSEP, Reactor aeration systems constrcuted of diffused aerationsystem of UPVC, FBBR( Fludized bed Bio Reactor) media constructed of UV Resistant PP ( Polypropylene) suitable for 400 sqm/ Cum, Lamella settler process Chmaber constructed of MSEP, Tube Settler media constructed of PVC tube media 750 mmVertical Height11 sqm/ cum at 60 degree with approx weight of 75 kg/cum UV stabilised PVC, Air BlowersConstructed of CI positive displacement creating pressure of 0.5 Kg /sqcm with horizontal foot mounted motor ( Air Blower with Motor-one working & one standby),Chlorine Cintact tank constructed of HDPE, Chlorine dosing system constrcuted of electroinic dosing pump with dosing tank in HDPE, All interconnected piping, Valves & fitting within STP constructed of UPVC, Sludge pumps constructed in CI impellar & Housing ( only working pump), Dual Media Filter Constructed in FRP with MPV, UPVC Piping & Media,Feed Pump for treated water in SS-304 Contruction for Impellar & Housing ( One Working+ One standby), Motor Control centre Complete with starters, contactors, overload relays etc for all pumps & Blowers, Electrical cabling & Glands from Motor Control Centre to all pumps & blowers, With Civil constructed items such as Screen Chamber of suitable volume size, Oil & Greese Chamber of suitable volume , Sewage Collection Tank of suitable Volume , Foundations for STP Skid, Pumps Blowers etc in RCC of 150 mm thick , Treated water Sump of suitable volume in HPDE & Sludge Draying bed Constrcuted in Brick Masonary. For the Capacity of 80KL/ day. The treated water shall be used for Horticulture, gardening & Toilet Flushing.( All civil work is included in the scope. All sizes and design to be approved from engineer incharge) 145 Excavating trenches in all kinds ofsoil of required width for pipes. including excavation for sockets and dressing of sides, ramming of bottoms, including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc & disposing of surplus excavated soil as directed within a lead of 50m. Pipes 80 mm to 300 mmdiameter 146 Providing and laying160mm dia upvc 10kg/cm2 pressure 150 mm.dia. UPVCPipes 147 Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design150 mm.dia. RCCPipes 148 Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design. Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg).With common burnt clay FPS (non modular) bricks of class designation 75(i) For Sewer Line 149 Extra for depth for manholes:Size 90x80cm with With common burnt clay FPS (non modular) bricks of class designation 7.5 150 Inside size 90x120cms and 90cms deep including CI cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58kg). With common burnt clay FPS (non modular) bricks of class designation 75 (i) For Sewer Line 151 Extra for depth for manholes: Size 90x120cm with With common burnt clay FPS (non modular) bricks of class designation 7.5 152 COST OF EXTERNAL WATER SUPPLY WORKS Providing & fixing G.I. pipes complete with G.I. fittings includingtenching and refilling etc. (external work) 50mm nominal bore. 153 Supplying and fixing of specials for pressure pipe. 154 Providing and fixing gate valve (with cap complete with bolts, nuts, rubber insertion etc. 155 Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick,finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 156 Excavating trenches in all kinds ofsoil of required width for pipes. including excavation for sockets and dressing of sides, ramming of bottoms, including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc & disposing of surplus excavated soil as directed within a lead of 50m. Pipes 80 mm to 300 mmdiameter 157 Providing and laying160mm dia upvc 10kg/cm2 pressure 150 mm.dia. UPVCPipes 158 Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design150 mm.dia. RCCPipes 159 Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design. Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg).With common burnt clay FPS (non modular) bricks of class designation 75(i) For Sewer Line 160 Extra for depth for manholes:Size 90x80cm with With common burnt clay FPS (non modular) bricks of class designation 7.5 161 Inside size 90x120cms and 90cms deep including CI cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58kg). With common burnt clay FPS (non modular) bricks of class designation 75 (i) For Sewer Line 162 Extra for depth for manholes: Size 90x120cm with With common burnt clay FPS (non modular) bricks of class designation 7.5 163 COST OF EXTERNAL WATER SUPPLY WORKS Providing & fixing G.I. pipes complete with G.I. fittings includingtenching and refilling etc. (external work) 50mm nominal bore. 164 Supplying and fixing of specials for pressure pipe. 165 Providing and fixing gate valve (with cap complete with bolts, nuts, rubber insertion etc. 166 Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick,finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 167 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 168 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 169 Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group A 170 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 171 Supplying and fixing of following sizes of medium class PVC Conduit with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required size- 25mm dia, 172 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, singlecore cable in surface/ recessed medium class PVC conduit as required.1 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 173 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, singlecore cable in surface/ recessed medium class PVC conduit as required..2 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 174 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, singlecore cable in surface/ recessed medium class PVC conduit as required.2 X 4 sq. mm + 1 X 4 sq. mm earth wire 175 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, singlecore cable in surface/ recessed medium class PVC conduit as required.2 X 6 sq. mm + 1 X 6 sq. mm earth wire 176 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, singlecore cable in surface/ recessed medium class PVC conduit as require 2 X 10 sq. mm + 1 X 6 sq. mm earth wire 177 Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25A modular socket outlet and 25 A modular SP MCB, C curve including connections, painting etc. as required. 178 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required 179 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. 180 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. TVantennasocketoutlet 181 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. Telephonesocketoutlet 182 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 183 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 1 or 2 Module (75mmX75mm) 184 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.3 Module (100mmX75mm) 185 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.4 Module (125mmX75mm) 186 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.6 Module (200mmX75mm) 187 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 8 Module (125mmX125mm) 188 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 12 Module (200mmX150mm) 189 Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. 190 Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. 191 Supplying & erecting decorative pre-wired box type fitting/batten suitable for 4 feet, T8 LED tube light (excluding tube light). 192 Supplying and erecting LED square / circular Max. 7W down lighter/ Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 770 Lumens, min. efficacy of 110 lumen/W,CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%,THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV,Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. 193 Supplying and erecting LED square / circular Max. 18 W down lighter/ Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 2000 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. 194 Supplying and erecting anodized aluminium corridor / passage light LED fitting (4 feet) Max. 22W with high transitivity diffuser with system lumens output of Min.2200 lumens , min. efficacy of 100 lumen/W, CRI>80, CCT upto 6000K, Beam Angle of 110 deg., Ripple<5%, THD<10%, p.f. >0.95, operating range of 200-270V, surge protection of 2 kV, Life class of 50,000 Hrs. at L70B50, including driver, with end caps on provided PVC Block / wooden board with 3 years warranty. 195 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLOC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copperwinding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min, 350 RPM (tolerance as per IS: 374-2019), THO less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase ACSupply, earthing etc. complete as required. 196 Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required 197 Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. 510 mm sweep 198 Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 1 run of cable 199 Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V C curve DP MCB complete with connections, testing and commissioning etc. as required. 200 Supplying and fixing TP sheet steel enclosure on surface/ recess along with 16/25/32 A 415 V C curve TP MCB complete with connections, testing and commissioning etc. as required. 201 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 A 202 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40A 203 Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 A 204 Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 A 205 Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 A 206 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)8 way Double door 207 Supplying and fixing Cable End Box (Loose Wire Box) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 Volts, on surface/ recess, complete with testing and commissioning etc. as required.For 8 way, Double door SPN MCBDB 208 Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (butwithout MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)12 way (4 + 36), Double door 209 Supplying and fixing Cable End Box (Loose Wire Box) suitable for triple pole and neutral, sheet steel, Vertical MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc. as required. 210 Supplying, erecting, testing and commissioning of 20kVA capacity online pure sine wave, with backup time of ....... hrs. PWM & IGBT based UPS with 0.9 to unity output pf, 3 phase input and 3 phase output complete with all protections as per specification no. AP-UPS 211 Supplying and erecting 12V/180Ah tubular battery with battery terminal wire, duly charged with 36 months warranty complete 212 Supplying, installing, testing and commissioning C-10 battery with capacity of 12V, 300 Ah with duty cycle 10-12 hrs. suitable to charge on PV cell with necessarywiring connections, nut bolts on provided stand with five years warranty as perspecification no. ESD-SOL/BAT 213 Supplying, installing, testing and commissioning C-10 battery with capacity of 12V, 150 Ah with duty cycle 10-12 hrs. suitable to charge on PV cell with necessarywiring connections, nut bolts on provided stand with five years warranty as perspecification no. ESD-SOL/BAT 214 Supplying, installing, testing & commissioning split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room airconditioning unit 1.0TR to 1.5TR capacity having ISEER minimum 3.8 tomaximum 4.39 suitable to operate on 250V, 50 Hz, A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32 having copper condenser, minimum 2.5PM filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dBA at position as per specification no. APAC/ WAC 215 Supplying, installing, testing & commissioning cassette type variable speedinverter technology with minimum 3 to 1 convertible mode for compressorroom air conditioning unit 1.5TR to 3.00 TR capacity having ISEER minimum5.00 suitable to operate on 250V, 50 Hz, A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32/R410A having copper condenser, dust filter, self diagnosis feature, stabilizer free operation, noise level maximum 50dBA at position as per specification no. APAC/ WAC 216 Supplying and erecting modular type T.V. socket single outlet, duly erected on provided plate and box with wiring connections complete. 217 Supplying and erecting broadband splitter unit with 1 input & 2 output RJ 11 female connectors complete. 218 Supplying and erecting modular type telephone socket one gang with safety shutter, duly erected on provided plate and box with wiring connections complete. 219 Supplying, erecting & commissioning 50 pairs FR junction box with moulded plastic enclosure as per specification no. WG-TW 220 Supplying & erecting 50 pair, 0.5 mm dia. jelly filled armoured telephone copper cable with poly-al laminate moisture barrier, polythene sheathed, G.S.Tape armoured polythene jacketed having laid in provided trench as per specification No. WG-TW 221 Supplying & erecting 0.5 mm dia, copper jumper wire as per specification No. WG-TW 222 Supplying & erecting co-axial copper cable low voltage grade tri-shielded RG- 11 as per specification No. WG-TW 223 Supplying and erecting 15m VGA cord low voltage grade to be laid in provided conduits and terminating with male/female VGA connectors complete 224 Supplying and erecting 15m HDMI cord low voltage grade minimum 4k compliant to be laid in provided conduits with male/female 19 pin HDMI connectors complete. 225 Supplying and erecting 15m Audio Video cord low voltage grade as per specification with required 3RCA x 3RCA connector complete. 226 Supplying & erecting HDMI Extender Over RJ45 Ethernet Cable Cat 6, 60m/200ft complete. 227 Supplying, installing, testing & commissioning of DVI to HDMI Convertor highspeedcategory, supporting full HD 1080p, 2K and 4K video up to 30 ft length, 3D having 24k gold-plated 19-pin Type-A connectors with high-flex CL3-rated jacket, RoHS compliant complete. 228 Supplying, erecting & commissioning MDF Box 50x50 pairs made from min. 1.5mm thick MS sheet as per specification no. WG-TW 229 Supplying & erecting rosette box RJ type Bakelite box on wall with LED indication duly connected as per specification no. WG-TW 230 Supplying and erecting broadband splitter unit with 1 input & 2 output RJ 11 female connectors complete. 231 Supplying, installing, testing & commissioning analogue type EPABX of 3 x 8 extension complete. 232 Supplying, installing, testing & commissioning push button telephone instrument desk top unit as per specification complete 233 Supplying, installing, testing & commissioning push button telephone instrument desk top/wall mount with caller ID & Speaker unit as per specification complete. 234 Supplying and erecting integrated LED street light fitting 70-75W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 7700 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K,THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FG-ODF/FLS2. 235 Erection of RCC/ PCC pole of following length in brick ballast and ramming the foundation, finishing with 150mm thick cement concrete (1:3:6) layer on top with including excavation and refillingetc as required.Above 6.5 metre and upto 8.0 metre 236 Making M- 20 cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq. m at 2 m depth including excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 16 m raising lowering high mast). 237 Supplying and erecting 16 m (clear height) motorized high-mast (Top-150mm, Bottom- 360mm) hot dipped galvanized material with average minimum thickness 65 micron, made from high tensile structure grade steel as per BSEN -10025 S 355/E350 & 3 mm thickness, with base plate 25 mm thick x OD 520 mm grade as per IS-2062, pole made in single section & submerge arc welded, with lowering & raising motorized unit, wire rope stainless steel 316 grade 2 nos., 7x19 construction 5mm, SG-DG U clamps, double drum winch assembly 350 kg, 5x2.5 sq.mm flexible copper cable with lantern carriage assembly suitable for max. 12 nos. luminaires and its control gear box, lightning arrestor, arrangement for fixing aviation light, high-mast with serial number, factory inspection report/test report of high-mast should be provided as per specifications on provided foundation J type stud/bolts with necessary accessories complete. specification no. OH 238 Supplying and erecting outdoor stand mounted feeder pillar for high-mast of the same manufacturer with 32A TPN MCB incomer, 24hr astronomical time switch with minimum 5 years battery backup, IP 54 and IK10 protection, 25 A TP contactor for automatic switching of luminaires, 2 no. 9A contactors and raise/lower push button, and provision for termination of adequate size of incoming and outgoing cables complete erected in min. 14 SWG CRCA sheet box with supporting angles, self lock, gasket and slanting top erected on CC foundation complete 239 Supplying & erecting three phase, 415V, street light control panel up to the max load of 12kW, TPN MCB 63A, powder coated CRCA 14 SWG sheet, outdoor type, having IP54,IK10 protection, suitable rating contactor, 24 hrs. astronomical time switch with minimum 5 years battery back up, auto/manual selector switch, ON/OFF push buttons, indicator lamps, controlwiring, metering device, etc. for automatic operation, with overcurrent, short circuit, earth fault protection on provided iron frame / CC foundation. 240 Aluminium lugs for 70 sq. mm cable 241 Earthing with copper earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 242 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 243 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. 244 Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V,up to 35 Sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL 245 Supplying & erecting single compression type brass cable glands for /3 to 4 core 25 sq mm /3 core 35 sq mm for XLPE armoured cable as per specification No. CB-GL 246 Supply & erection lighting arrestor complete with The new OPR (Optimized Pulse Rod) range with increased initiation advance performances, represents further progress in terms of protection, operating autonomy and ease of maintenance. The radious of protection of OPR is not less than 30 meter. included with GI strips having size of 25 x 5 mm, & two nos earthing with maintenance free earth rod 3.0 meter long earth junction point connected to main lighting strip, counters, supporting arrangement to erect the rod at top of building, required foundations as per direction of electrical incharge, etc. (Equivelent to OPR 30 ABB or SGI make, model Taran) 247 Making cement concrete foundation in 1:3:6 cement concrete, (20 to 25) mm.stone metal duly plastered with necessary curing for complete. (pole muffing or any other purpose). ( for Lightening Arrestor) 248 Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. 249 Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15 mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and re-filling as required. 250 Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, up to 35 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU 251 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required .Upto 35 sq. mm 252 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated andPVC sheathed / XLPE aluminium conductor cable of 1.1 KV gradeas required.2 X 6 sq. mm (19mm) 253 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated andPVC sheathed / XLPE aluminium conductor cable of 1.1 KV gradeas required.2 X 10 sq. mm (19mm) 254 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated andPVC sheathed / XLPE aluminium conductor cable of 1.1 KV gradeas required.2 X 35 sq. mm (25mm) 255 (The outer door of the panel is such that user can work/handle it properly, locking arrangement with key should be provided by Bidder . The Panel is Outdoor and Should be manufactured as per IP65 Protection ) Lighting & Power Panel MAIN TEMPLE AREA(Location-:In room no.3) with incomer of 200 A MCCBand Bus bar of 400 A (35kA) s with required metering , CT , Relay and indication lamp with outgoings details as given below Out Goings ( All MCCB shall be microprocesser based with O/L, S/C and E/F Protection , On /OFF/ Trip indication lamp with KWH meter) 1) 63A 4P MCCB 35KA of 8No.s . 256 PLUMBING PANEL(Location-:In room No.3 near to main temple hall) with incomer of 200 A MCCB with bus bar of of 200A (35 kA) with required metering , CT , Relay and indication lamp with outgoings details as given below. Out Goings ( All MCCB shall be microprocesser based with O/L, S/C and E/F Protection , On /OFF/ Trip indication lamp with KWH meter 1) DOL Starter for 5kw of 7No.s 2) DOL Starter for 3.7 kw of 3No.s . 257 Supplying, erecting & marking SPMCB 40A to 63A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB 258 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders inexisting cubicle panel board including drilling holes in cubicle panel,making connections, etc. as required.100 A, 16 KA,TPMCCB 259 Supplying, installing, testing and commissioning air circuit breaker manual fixed type, non-drawou type, 650V, 1000A rated at 50º C without deration, 12kV Impulse, 4 Pole (100% Neutral Protection), 50 kA (Ics=Icu=Icw for 1s),with standard accessories with ready to close, individual fault trip, alarm and trip indication, mechanical and electrical anti pumping, soft/ hard rating plug(including hard rating plug CT) with Micro-processer based LCD display release with LSIG and temperature rise protection & with 4 C/O contacts for On-Off-Trip indication, min. 5 event and trip history on breaker display on provided iron frame as per specification no. SW-SWR/ACB 260 Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority. 261 Supplying and erecting self-locking arrangement with keys in duplicate, made of brass of grade 1 compliance to IS 729-1979 duly erected, flush with surface of panel / cupboard 262 Supplying and erecting of any size electrolyte aluminium patti or bar in bus bar chamber / in panel or any other purpose, 500 V with require capacity 99.9% aluminium purity with E91E Grade as per IS 5082 & Current Density 0.8 A per sq. mm. with fixing arrangement (like lug or bottle type lug) to both the end with high grade polyolefin insulation sleeve complete as per specification no. BCPBB 263 Supplying and erecting panel mounting type digital ammeter having three and half digit LED display, external CT operated, calibrated for suitable to operate on 500V, 0 to 1000A having accuracy class of 0.5, AC supply with necessary PVC wire leads and lugs and mounting hardware on provided panel complete with calibration certificate from manufacturer. 264 Supplying and erecting panel mounting type digital voltmeter having three and half digit LED display, calibrated for 0 to 750V AC suitable to operate on 500V having accuracy class of 0.5 ,AC supply with necessary PVC wire leads and lugs and mounting hardware on provided panel complete with calibration certificate from manufacturer. 265 Supplying and erecting selector switch suitable for voltmeter/ammeter for 3 phase AC supply 500V, 50Hz, on provided box / panel and duly connecting with necessary PVC wire leads and lugs. 266 Supplying and erecting LT current transformer with bar primary 50/5 to 1000/5 ratio with 15 VA burden erected in provided CRCA box duly secured with insulating materials connected to the meter with test certificates. 267 Supplying, installation & marking of surge arrestor/ surge protection device at the main distribution board after the incoming breaker of type 1+2 tested for Imax 50 kA for three phase and neutral with compliance to IEC 61643-11 as per specification no. CP-SPD 268 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) as required 269 Supplying, erecting, testing & commissioning 11kV, 630A, 21kA/3sec, 1 way Indoor/outdoor, extensible motorised SCADA compatible RMU, internal arc tested consisting of 1 no. feeder with 1 LBS compliant to IEC 62271-100, 200 and 102, as per specification no. SW-HTS/RMU SCADA 270 Supplying, erecting, testing and commissioning 11KV HT metering cubical (compact / vertical type) approved by EB / licensee fabricated with 2 mm (14 SWG) M.S. sheets with supporting angle, painted with powder coating / epoxy paint of required shade, copper bus bar size 25 x 6 mm, heavy duty mechanical lock, with counter meter for measuring no of times the opening of meter door, top side cover (CT, PT cover) interlock with meter door, epoxy casted 3 nos. CT having required ratio between 50/5A to 200/5A, VA 10 or 15, Class 0.2S, epoxy casted 3 nos. PT having ratio 11000/V3/110/V3 VA 50, Class 0.2 suitable for provided trivector meter, and provision for incoming and outgoing cables complete duly tested by licensee with necessary test certificates and erected on provided plinth/ cc foundation. 271 Supplying and erecting 50 kVAr, 440 V 3 phase, 50 Hz., Contactor Logic &Intelligent Relay micro APFC passive filter panel, consisting of suitable steps of APP/MPP type capacitor units with Detuned (harmonic filter) reactors ofsuitable rating , APFC panel shall be compliance to IEC 61439 and power qualityIEC 61921 standard as per specification no CP-ED/APFC 272 Supplying , erecting & terminating XLPE insulated, galvanised steel formedwire armoured (strip) cable 11 kV(E), 3 x 95 sq. mm. aluminium conductor laid in provided trench / pipe as per specification no. CB-HT 273 Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed cable of 1.1 KV grade as required.3/2 X 120 sq. mm 274 Providing and erecting Heat shrinkable outdoor termination kit for 11 kV ( E ) XLPE HT cable 3x120 sq. mm. with necessary material as per specification no. CB-JT/H 275 Supplying, installing, testing & commissioning 3 phase, 11/0.433 kV, 50 Hz., 200kVA, Mineral oil immersed and naturally cooled outdoor type, Copper wound, without gas cushioning ,hermetically Sealedtransformer, delta/star connected with additional neutral brought out on load side, temperature riseshould not exceed 40℃ by thermometer in oil and 45℃ by the resistance methodin winding at full load rating, using type A winding insulation (kraft paper), with HV tapping (with off load tap changer) off load +2.5 to-5 in steps of 2.5%, having 4 number of tap positions, with standard accessories completewith test certificate with losses below 780 Watts at 50% load, 2300 Watts at100% load as per IS:1180 (part 1) : 2014, with necessary permissions of Electrical Inspector, as per specification no SS- TR-S 276 Supplying, erecting, testing and commissioning of microprocessor based AMF panel suitable for diesel generating set of above 180 kVA up to 200 kVA capacity Three phase, 415 Volts, 50Hz A.C. with all standard features, safeties etc as per specification no. GEN-AMF. 277 Supplying, erecting, testing and commissioning of diesel generating set withalternator of 200 kVA output continuous rating, 3 Phase, 415 V, 50c/s 0.8 p. f.A.C supply, a totally enclosed air cooled / liquid cooled multi-cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12hours, along with standard accessories, self-excited, self-regulated, screenprotected alternator with static excitation system running at 1500 RPM as per IS4722-2001 with voltage regulation +/- 5 %, with performance class G2 andmaximum fuel consumption 34.40 Ltr/hr @75% loading. Both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti-vibrating pads with standard control panel comprising meters,switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite Acoustic enclosure as fully assembled integral unit made of16 SWG CRCA Sheet, sound absorbing material to restrict sound level up to 75 dB(A) at 1.0 m, provided with first filling of oil, diesel not less than 300 Ltr etc.on provided M20 Grade CC Foundation as per specification no. GEN-DG 278 (A) Supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Diesel Driven Pump)(B) Horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520.(C) Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required.(D) M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc.as required.(E) Suitable cement concrete foundation duly plastered and with anti vibration pads. Rating----------2850 LPM at 56m head 279 (A) Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Jockey Pump)(B) Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conformingto IS: 1520. (C) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-F insulation, conforming to IS: 325. (D) M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required.(E) Suitable cement concrete foundation duly plastered and with anti vibration pads. Rating 180 LPM at 56 m Head 280 Control Panel- Fabrication supply, installation, testing and commissioing of Electrical Control panel of Cubical Contruction, Floor Mounted Type 281 MS. C Class Pipe- 150 mm dia with anticorrosive treatement 282 MS. C Class Pipe- 150 mm dia 283 MS. C Class Pipe- 100 mm dia 284 MS. C Class Pipe- 80 mm dia 285 Single headed Gunmetal External Hydrant valve 286 Butterfly valve 150 mm dia PN 16 287 Butterfly valve 100 mm dia PN 16 288 Butterfly valve 80 mm dia PN 16 289 Orifice Plate 290 Non return valve 150 mm dia PN 16 291 Non return valve 100 mm dia PN 16 292 Non return valve 80 mm dia PN 16 293 Y strainer 150 mm dia PN 16 294 Y strainer 100 mm dia PN 16 295 Y strainer 80 mm dia PN 16 296 63 mm dia, 15 mtr RRL Hose pipe with GN metal 297 First Air Hose Reel 20 mm internal dia- 30 m Hose reel length 298 63 mm dia short branch pipe with 20 mm internal dia bore- Gunmetal 299 Fire brigade Connection 2 way- 100 mm dia Ms Pipe 300 Fire brigade Connection 4 way- 150 mm dia Ms Pipe 301 Air vessel 250 mm dia 302 Pressure Switch 303 Manual call Boxex 304 Fire alarm Sounder 305 Talk Back Slave station 306 Sector panel- 10 zone 307 Main Control and Indicating panel 308 2X1.5 C fire survival cable 309 25 mm dia PVC Conduit 310 Providing and placing on terrace (at all floor levels) polyethylene water storage tank of approved brand and manufacture with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.DSR-14(18.48) 311 S u p p l y i n g& erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg. capacity cartridge type conform to IS 2878 /15683 complete erected with necessary clamp made from 50 x 6 mm. M. S. flat with nut & bolts routed in wall complete. 312 Supplying and erecting ABC powder typefire extinguisher as per IS : 13849 /15683 of 9 Lit capacity with necessary clamp for erection on wall. 313 Supplying and erecting round bottom FIRE Bucket of 9 Litres capacity as per IS : 2546 made out of 24 gauge G.I. sheet with extra handle at bottom duly painted white inside and red outside with FIRE Mark, on provided stand/ wall hook. 314 Supplying and erecting floor mounting stand for keeping 3 Nos. of FIRE buckets 1500mm in length, 900mm in height frame made out of 30x30x4 mm angle iron with cross supports for legs, welded with 3 hooks and duly painted with one coat of red lead and two coats of silver paint. 315 Providing & fixing standard firemans axe with heavy rubber handle. 316 Providing and fixing standard fire hose cabinet door (1000mm x 1800mm) suitable to fit in the duct made of not less than 16 SWG MS sheet having central opening glassed door (4 mm thick clear glass) including necessary locking arrangement with handle as required including painting (one coat primer and two coats of fire red colour).The door shall be fixed in the masonry wall or as required.The words Fire Hose to be painted on the box. 317 SITC of IP 2 MP infrared dome network camera for floor monitoring, H.265, POE day night vision with, 2.8 mm fixed lens. Camera shall be full HD with video quality of 1080p video dual stream, 120dB wide dynamic range and 3D digital noise reduction. Camera shall be 3-axis adjustment backlight compensation IR range up to 30m. Camera shall operate on DC12V and shallsupport H.265. Shall have communication Interface of 1 RJ45 10M/100M ethernet port. Shall have provision of alarm trigger tampering for network disconnect, IP address conflict , shall be capable of detection intrusion detection, line crossing detection, motion detection, video bit Rate 32 Kbps ~ 16 Mbps , shall have shutter speed 1/3 s to 1/100,000 s , shall have minimum Illumination 0.01Lux @ (F1.2, AGC ON), 0 Lux with IR. Techincal datasheet approval shall be taken by vendor from consultant before material delivery. 318 SITC of 32 channel NVR with H.265+ compression technique, full channel recording up to 8 MP resolution.Up to 4 SATA interfaces for HDD connection with each HDD of capacity of 6 TB. HD output up to 4K resolution. Self adaptive 10/100/1000 MBPS. Incoming bandwitdh 256 MBPS, outgoing bandwidth 160 MBPS. 2 Nos of RJ45, HDMI and VGA ports.Working condition -10 deg c to 55 deg c. Input power less han 80 watt.Two numbers of USB 2.0 and USB 3.0 interfaces.Vendor shall provide 1 year warranty on NVR. Techincal datasheet approval shall be taken by vendor from consultant before material delivery. 319 SITC of FRPVC CAT 6 Cable for cameras shall consists PE Insulated 23AWG solid bare copper conductors dia 5.89mm, twisted 4 pair stranded UTP cable, current rating Max 1.5Amp, Dielectric strength 1000V RMS. UL Listed. Techincal datasheet approval shall be taken by vendor from consultant before material delivery. 320 SITC of primarystorage - internal surveillance harddisk for minimum 30 days back up. Internal hard disk shall be in 10 TB configuration.Techincal datasheet approval shall be taken by vendor from consultant before material delivery. 321 SITC of 8 port POE network switch with accessories and eclosures required. POE switch with bandwidth of 10/100/1000MBPS, switching capacity of 56 GBPS, power output 70 watt , power input shall be less than 70 watt, operating temperature up to 50 degree centigrade.Techincal datasheet approval shall be taken by vendor from consultant before material delivery. 322 SITC of Network rack 15 U for switches along with exhaust fan and PDU including mounting accessories, Vision glass shall be available. Rack shall have IP 55 rating. Techincal datasheet approval shall be taken by vendor from consultant before material delivery. 323 SITC of 25 mm PVC rigid MMS conduit with al required accessories like saddles, bend, coupler, junction box, T socket whereever required 324 24 port patch panel loaded with keystone and required accessories. Techincal datasheet approval shall be taken by vendor from consultant before material delivery. 325 Supplying, erecting, testing and commissioning 120 W amplifier suitable to operate on 230 Volts A.C. / 12 Volts D.C. supply complete as per specification no. 326 Supplying, erecting, testing and commissioning 15 to 30 Watts sound column or ceiling mounted complete as per specification no. 327 Supplying, erecting, testing and commissioning of 2 core shielded cable complete as per specification no. FF-PA/MCC 328 SITC of 8 zone public address system controller system with LCD screen, paging station, 8 zone calling station,with FM/AM tuner and all required accessories. Public address system shall have facility of auto alert messages announcement in case of fire based on fire alarm input in case of an emergency. All system hardware shall be submitted to project team at the time of handing over of the system. Public address system shall be interfaced with fire alarm system in a building. Automatic announcement shall be enabled in case of fire detection by fire alarm system. All cables shall be provided with tagging. Techincal datasheet approval shall be taken by vendor from consultant before material delivery. 329 SITC of 8 zone paging station along with required connecting cables and accessories. Rated input power 10W, input sensitivity 5mv, input impedance 600 ohm, optimal pick up distance 10-20cm. Techincal datasheet approval shall be taken by vendor from consultant before material delivery. 330 SITC of back box of required size for mounting on true ceilingwhere ever required. 331 SITC of 60 watt volume controller forspeaker in all zones. Volume controller shall be installed in controller room. Techincal datasheet approval shall be taken by vendor from consultant before material delivery. 332 SITC of FRLS 2 core 1.0 sqmm copper conductor, overall shielded, twisted pair,PVC insulated and armoured cable. It includes , proper fixing , saddling , tagging of cables and making wall good in all respect. Cable shall withstand voltage up to 500 volt. Shall have characteristic impedance of 100 ohm , current rating 11 amp at 40 degree Celsius. Armoured thickness shall be minimum of 0.9mm GI. Conductor DC resistance is 19.5 ohm / km. Cable shall conform to IS 694. Techincal datasheet approval shall be taken by vendor from consultant before material delivery. 333 Supplying, fixing, and configuring 24 ports + (4 SFP+) POE switch, 370W, 6KV surge protection on ethernet port and console port for management on provided rack as per specification No. WG-NWC/ENS 334 Supplying, fixing, and configuring 1-port mini-GBIC SX MM fibre transceiver (up to 550m, support 3.3V power) erected in provided rack complete. 335 Supplying, fixing, and configuring broadband ADSL router with all accessories, on provided rack as per specification No. WG-NWC/ADSL 336 Supplying, installing and testing UTP connector (RJ-45) as per specification No. WG-NAS/UTPC. 337 Supplying and installing cat-6 cable suitable for networking as per specification no. WG-COC/NC 338 Supplying and erecting modular type computer Jack RJ45 with safety shutter, duly erected on provided plate and box with wiring connections complete. 339 Supplying and fixing wireless n 150 desktop adapter in provided computer as per specification No. WG-NAS/LANC2 340 SITC of Electric Traction Passenger Lift with · Rated capacity :- 6 Passenger/408 Kg· Floors :- G+2 floor (3 Stops/3 Landings) · Travel :- 9.5 mtrs.· Location of Lift Machine:- MRL · Rated speed :- 1.0mps VS · Car/Landing door clear opening of 800 mm wide x 2100 mm high · Clear Car size of 1000 mm wide x 1200 mm deep x 2200mm high · Lift shaft available having clear size of 1500 mm wide x 1500 mm deep, 1400mm Pit depth, 4200mm Overhead. ( 2200+2000) · Doors type :- COPO Doors with Full Glass with frame made from SS 304 grade solid(non-cladded) sheet of 1.5mm thick in hairline finish for car and all landing doors with SS door architraves/frames The lift doors shall have minimum 1 hour fire rating (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory).· Lift car enclosure made from SS 304 grade solid (non-cladded) sheet of 1.5mm, thick with hairline finish with frame made from MS girders, bracing of adequate size with minimum safety factor of 5, with Toe Guard Apron, with necessary false ceiling with adequate LED lights, blower/fan for ventilation & SS chequered plate flooring, handrails, mirror, emergency light etc. The lift car interior design shall be done as per the directions of engineer in charge.· COP with SS face plate having metallic push buttons with Braille code & luminous indicator around button with FPI, scrolling UP/DN LED indicator & with / without attendant key switch, OWD with audio-visual alarm, VAS in Marathi, Hindi & English with intercom system with telephone instrument in Lift car, LMR & FCC/ground floor.· LOP with SS face plate having recess/surface push button box for all landings with scrolling UP/DN LED indicator having metallic push buttons with Braille code & luminous indicator around button with CPI, Lift car arrival & next travel direction audio-visual indication at all landings.· The system can record information for minimum 30 latest faults, with real-time clock management and handheld keypad with LCD screen for view and setting of parameters. Fireman controller having fireman switch at fire Landing.· CCTV surveillance system comprises of 2 nos minimum 2.0 MP FHD IP based vandal proof Dome camera in lift car & in LMR/inside lift shaft top aimed on Lift machinery & controller with NVR kept in LMR/FCC with HDR data backup min. 90 days with min. 18” FHD TV monitor, to be kept in FCC/LMR as directed by Engineer In Charge.· Lift Machine of Gearless PMSM of suitable kW with duty cycle of minimum 120 starts/hr (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory), with Traction pulley, OSG, electromagnetic brakes, entire assembly mounted on adequate size girders duly fixed on LMR floor/ shaft walls complete with main/diverter traction sheaves, suspension wire ropes/belts of adequate size & strength.· Other mechanical parts such as T section adequate size guide rails for car & counter weight with brackets fasteners, counter weight frame with necessary blocks, buffers with necessary support arrangement, MS pit ladder etc. erected with necessary steel work Minor civil work such as alteration work if any necessary for erection of landing door frames and its accessories e.g. sill, header, hole pass etc complete with plaster finish, civil work for erection buffers, erection of lift machinery, adequate size core cuts if required & scaffolding for erecting guide rails, providing and fixing steel girders/RCC work having adequate strength for mounting and hoisting lift machine etc. complete as per specification no. LFT.· General: - Job includes entire procedure of obtaining all necessary erection permissions & License to Work the Lift from Electrical Inspector (Lifts) with submission to the Engineer In Charge.· The above rate includes Fully Comprehensive AMC for one year from the date of commissioning 341 Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 6 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU 342 Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB 343 Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 2 ways (2 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB 344 Supplying, erecting & commissioning 2 pole RCCB 40A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB 345 Supplying, erecting & commissioning 4 pole RCCB 63A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB 346 Supplying and erecting bulk head LED fitting max. 10W with high transitivity diffuser with system lumens output of min. 1100 lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., THD<10%, p.f. >0.95, operating range of 140-260V, in built surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, IP66, IK09 rated on provided PVC Block / wooden board with 3 years warranty. 347 Supplying and erecting ISI mark modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete. 348 Supplying and erecting ISI mark modular type 3 pin 6 / 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete. 349 Supplying and erecting PVC Surface modular switch box with double mounting plate for 6 modules duly erected. 350 Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 2 core 2.5 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU 351 Providing earthing with copper earth plate size 30 x 30 x 0.315 cm complete with all materials, testing & recording the results asper specification no. EA-EP 352 Supplying & erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame. 353 Supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.

Key Value

Document Fees
INR 17700 /-
EMD
INR 2899000.0 /-
Tender Value
INR 14.49 Crore /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail